thx11-模拟式控制器
- 格式:pdf
- 大小:304.91 KB
- 文档页数:13
专业音视频名词解释2004-11-30 RFI RF interferece 射频干扰Revcolor 混响染色声RPS direct program 直接节目搜寻,卡拉OK搜索R(RD)radio 射频R(RD)read 读取R receiver 接收机R register 寄存器R right 右声道Rack 机架,支架,机柜,规定宽度,震动声Radiation 辐射Radio 无线电,惦音机,射频Ram random access memory 随机存储器RAM 填入,装入RAN random 随机的,任意的,无规则的Range 范围,最大提衰量,幅度Rate 比率,速率,变化率,频率Ratio 压缩比,扩展比,比,系数RCA radio corporation of America 美国无线电公司RCA jack 莲花接口R-CH 右声道R-DAT rotary head-DAT 旋转磁头式数字录音机RE rack earth 外壳接地RE reset 复位RE right end 右端Reactance 电抗Readjustment 重调Ready 预备,准备完毕Rear 背面,后部,后置REC recording 录音,记录,录制Recall 招回,调出,重录Receiver 接受机,接受器Recharge 再充电Record 记录,录制,唱片Recorder 录音机Recovery 恢复,复原Red 红色Redo 再执行操作Reduce 减少,降低,缩小Reduction 压缩,衰减,形成Reecho 回声REF Reference 说明书,参考,基准,定位REF Reflection 反射Refraction 折射Refresh 恢复REG register 寄存器REG regulate 控制,校准,调节REGEN regeneration 再生(混响声阵形成方式),正反馈Rehearsal 排练,预演Reject 除去,滤去Rejection 抑制Reinforcement 扩声Relay 继电器,重放,转放Release 恢复时间,释放,断路器Rename 改名,命名Remain 保持,剩余REM remote 遥控的,遥远的,远距离的REM removable 可拆装的REM remove 除去Remain 余量,状态保持Renumber 重写号码REP repeat 重复,反复,重放Repeat mode 双面反复放音(录音机)Replacing 替换,置换,复位REQ room equalizer 房间均衡器Reset 复位,恢复,归零,重复,重新安装Resolution 分辨率,分析Resonance 共振,回声RESP response 响应,特性曲线,回答Resistance 阻抗Resister 电阻Resonance 共鸣,谐振 Rest 休止符,静止,停止Restraint 抑制,限制器RET return 返回,回送REV reverse 颠倒,反转REV reverberation 混响,残响Reverb depth control 混响深度控制RIAA recording industry association of America美国录音工业协会S-TSAF Safety 安全装置,保险装置,保护装置Safeguard by 防护器SALT symmetry air load technique 对称空气负载技术Samba 桑巴Sample 声音信号样品,采样,取样,抽样Sampling 抽样,脉冲调制SAP second audio program 第二套音频节目SAT saturate 饱和效果处理Save 贮存Save 存储,保存Saxophoneb 萨克司管Saxophome 顶馈直线天线SC set clock 置位时钟SC sigmal control 信号控制SC subcarrier 副载波SC system controller 系统控制器SC scan 扫描Scale 音阶,刻度尺标Scale unit 标度单位,分频器Scan 搜索,记录,扫描Scar 激光唱片上的缺陷 SCART connector欧洲标准21脚AV接口Scattering 散射Scene 实况,场面SCH search 搜索,寻找Scheme 设计图,原理图SCMS serial copy management system 成套复制管理系统Screw 螺丝钉Scrollback 回找SCH stereochrous 立体声合唱Schmidt trigger 施密特触发器Scintillation 闪烁,调制引起的载频变化SCMS successive copy manage system连续复制管理系统(DAT设备中防止多次转录节目的系统)Scoop 戽斗,收集器Scope 范围,显示器Scoring 音乐录音SCR signal to clutter ratio 信噪比SCR silicon controlled rectifier 晶闸管整流器Scraper 刮声器Screen 屏蔽SD space division 空间分布S-DAT stationary head DAT 固定磁头DAT机SDDS sony dynamic digital sound 索尼动态数字环绕声系统SDI standard data interface 标准数据接口SDLC synchronous data link control 同步数据链控制器SE single end 单端的SE sound effect 音响效果SE storage element 存储元件SE support equipment 支援设备SEA soond effect amplifier 音响效果放大器SEA special effects amplifier 特殊效果放大器Search 搜索,扫描Searcher 扫描器SEC Second 秒,第二SECAM sequential color and memory 调频行轮换彩色制式Section 单元,环节Sectoral horm 扇形号筒Security 保险,加锁SED system effectiveness demonstration 系统效果演示Seek 搜索SEL selector 选择装置,寻线器,转换开关Select 选择Selectivity (收音机)选择性Semi- 半-Semibreve 全音符Semioctave 半个八度音Semit 半音SEN sensor 传感器Send 送出,发送,发射SENS Sensitivity 灵敏度Sense 分辨率Sensor 传感器Sentinel 发射器,传送器SEP standard electronic package 标准电子组件SEP system engineering process 系统工程处理Separator 分离器,分解器Septieme 七倍音SEQ sequencer 音序器,定序器SEQ Stereo equalizer 立体声均衡器Sequence 排序,序列Series 系列,串连Service 维修,服务Servo 伺服机构,随机系统Servo motor 伺服马达SES spatial effect system 立体声空间效果系统Session 跟随自动伴奏Set 调整,设定,装置,定位,接收机Setout 开始,准备Setup 设定,构成,菜单,组合,调整SFC sound field composer 声场合成装置SFL stereo flange 立体声法兰镶边SFS sound field synthesis 声场合成SG signal generator 信号发生器SGL signal 信号S-hall small hall 小型厅堂效果Shake 震动Shape 波形,轮廊Shaper 整形器,脉冲成形Share drum 小军鼓Sharpness 清晰度,鲜明度,锐度Shelving 滤除,滤波处理SHG sub harmonic generator 次(分)谐波发生器Shield 保护,屏蔽Shift 转换,变调,移频,漂移Shock 冲击Short 短的Short gate 短时选通门(混响效果)Shower 指示器,显示器SHUF Shuffle 随机顺序节目播放Shunt 分路,并联SHUTT shuttle 变速搜索,往复SI sneak in 淡入Sibilance 齿音,咝音Sibilant 咝音Sibilation 咝音,高频声畸变SICS sound image control system 声像控制系统Side 边,面,侧面,方面Side chain 旁链SIG signal 声音信号Signature 特征,音乐的调号SIF 伴音中频Silencer 静噪器Silent 静噪调谐Simple tone 纯音Simplex 单工Simulate 模拟的Simultaneous 同步,联立SINAD signal to noise and distortion ratio 信号对噪声和失真比Sine wave 正弦波Single 单,单次的,单独的,单碟SIP solo in place 独奏入位SIP standard information package 标准信息包Siren 旋笛Size 尺寸Razor1911 编辑于 2004-02-10 1138--------------------------------------------------------------------------------You better lose yourself in the music, the momentYou own it, you better never let it goYou only get one shot, do not miss your chance to blowThis opportunity comes once in a lifetime yoYou can do anything you set your mind to, manRazor1911发帖 19积分 15于2004-02-10 1139--------------------------------------------------------------------------------Skew control 扭曲校正,菱形失真器Skip 跳跃,省略SL signal level 信号电平Slap 拍打效果Slap back 山谷回声Slap reverb 山谷混响效果Slate 预定,标记,(录音调音台)标记开关Slave 从属的,从机,从动的Sleep 睡眠定时开关,静止Sleeve(SLE) 接地点,袖端,套Slew rate 瞬态率Sliding tone 滑音Slope 斜率,坡度,跨导Slow 慢速SLP super long play 超长(三倍)时间播放Sliding tone 滑音SLS studio listen 演播室监听SM sequential machine 时序机 SM signal meter 信号强度计SM storage mark 存储标志SM speechmusic 语言音乐SN signal-to-noise radio 信噪比Small club 小俱乐部效果Smear 曳尾,拖尾,浑浊不清Smear correction 拖尾校正SMF Standard MIDI File 标准SMP sampler 取样器SMPTE society of motion picture television engineers(美国)电影及电视工程师学会SN signalnoise 信号噪声,信噪比SND sound 声音,音响,伴音Snake 集体线Snapshot 片段,场景状态设置Snubber 缓冲器,减震器SO sneak out 淡出Socket 插座,插口Soft 软的,柔和的Soft click 柔性箝位Soft knee 软拐点(压限器)Soft-touch 轻触式Software 计算机软件Solo 独唱,独奏Sone 宋(响度单位)Song 乐曲Sound colum 声柱Sound field 声场Sound image 声像Sound intensity 声强Sound shadow region 声影区Sound cousole desk 调音台Source 声源SOS sound on sound 叠加录音SP speaker 扬声器SP speed 速度SP standard-play 标准走带速度录放SPA stereo pan allochthonous 立体声声像漂移Space 间隙,空间效果Spaciousness 空间感ST stereo 立体声,立体STI speech transmission index 语言传输系统Sticks 操作杆,安置,卡子Still 静止STM send test massage 发送测试信号STO stand point 位置STO stereo 立体声STO stop 停止STO store 存储,存储器STP shielded twisted pnir 屏蔽双绞线Strike note 击弦音,撞击声String instrument 弦乐器Strip 卸下附属设备,轨道,类别Strobe 选通脉冲,频闪放电管Strong 有力的Structure 装置,结构STU Studio 演播室效果SUB 副,辅助,附加,低音Subgroup 副,(调音台的通道集中控制网络)编组Suboctave 次八度Subsonic 次声,超低音Subwoofer 超低音Sum 和,总和,总数SUP Supply 电源Supper 超Super bass 超低音Super over drive 超激励Suppressor 抑制器Support programs 支援程序SUR Surround 环绕声,环绕,包围Sustain 保持,维持SVP surge voltage protector 浪肖电压保护器SW signal wire 信号线SW S-Wite 塞套引线SW switch 开关,切换SW short wave 短波SW specification of wiring 布线规格Swap 交换,调动(等量齐观),调换Sweep 扫描,曲线Swell 增音器Swing 摆幅,摇摆舞Swishing 飕飕声SX simplex 单工SXE stereo exciter 立体声激励器Symphobass 调谐低音系统Symphonic 交响,谐音SYS Ex system expanding 系统扩展TRIG trigger 触发,触发器,触发脉冲Trim 调整,微调,调谐,削波TRK track 音轨TRK trunk 总线,母线,干线Trouble 故障Trumpet 小号TRS time reference system 时间基准系统TST test 测试TTY teleltypewriter 遥控打印机,电传机Tube 电子管,真空管Tune 调谐,和谐,调音Tuner 调谐器Tunetable (唱盘的)转盘Tunnel reverb 隧道混响效果Tupe 处理模式Turbo distortion 涡轮失真效果Turntable 电唱盘,转台TV television 电视Tweeter 高音扬声器·Twin channel 双通道Two complement 补码Two way mode 双面轮流放音模式(录音机)TX transmit 发送,发射TX transmitter 发射机TYP trpe 类型Typical 标准的,典型的TRIG trigger 触发触发器,触发脉冲Trim 调整,微调,调谐,削波TRK track 音轨TRK trunk 总线,母线,干线Trouble 故障Trumpet 小号TRS time reference system 时间基准系统TST test 测试TTY teletypewriter 遥控打印机,电传机Tube 电子管,真空管Tune 调谐,和谐,调音Tuner 调谐器Tunetable (唱盘的)转盘Tunnel reverb 隧道混响效果Tupe 处理模式Turbo distortion 涡轮失真效果Turntable 电唱盘,转台TV television 电视Tweeter 高音扬声器Twin channel 双通道Two complement 补码Two way mode 双面轮流放音模式(录音机)TX transmit 发送,发射TX transmitter 发射机TYP type 类型Typical 标准的,典型的T talk 呼叫,联络Tab 防误抹挡片TACH tachometer 测速器TADI time assigument digital tnterpolation 时分数据插空(技术)Tag 电缆插头Take 实录Takeoff 取出Takeover 恢复,话音叠入,商议Talkback 对讲,联络Tally 播出,提示,插入Tap 电流输出,节拍Tape 带,磁带Tango 探戈TB talkback 对讲回送TB terminal board 接线端子子板TB time base 时基TBC time base corrector 时基校正器TBK tallback 对讲TC telecine 电影电视机TC time code 时间码TC transmitter-tunning circuit 发射机调谐电路TC trim coil 微调线圈TCC tripl concentric cable 三芯同轴电缆TDE time domain equalizer 时域等化器TECH technique 技术,技能,技巧TED television disk 电视唱片TEL telescopic 拉杆天线TEMP temperature 温度Temp 节奏TEMOP temporary 中间(工作)单元TEMPO Tempo 节奏,连接,速度Terminal 终端,接线柱,引线,接头Tentelometer 张力表TER termination 终端Test 测试,试验,检验THD total harmonic distortion 总谐波失真Theater 剧场效果,现场Thermal noise 热噪声Thick 沉重,厚重度Thin 单薄声音Thinness 薄(打击乐)THR THRESH threshold 阈值,阈,门限Thresh thrash 多次反复Three dimension 3D音响,三维立体声音响系统Throat 高音号角的喉THRU through 通过,过桥,直接转送Trump 键击噪声,低频噪声,开机砰声Thrust 插入,强行加入THX tom holmans eXpriment 汤·霍尔曼实验,家庭影院TI temperatun indicator 温度指示器TIE terminal interface exchange 终端接口交换Tie 连接符号,馈线,通信Tierce 第三音,五倍音Tight 硬,紧,硬朗TIM transient intermodulation 瞬态互调失真Timber 音质,音色Timbre 声部Time 时间,倍,次,定时的Timer 定时器,计时器Tininess 单薄Tint 色调TIP terminal interface processor 终端接口处理机Tip 头端,热端Title 标题,字幕TK track 音轨TL track loss 轨迹丢失TLE trunk line equipment 干线设备TM trade mark 注册商标TMS transmission mesurement set 电平表TMT transmit 发送TN tuning unit 调谐装置TOC 节目目录Tone 音调,声调,纯音Tone burst 猝发音Tone color 音色Tone quality 音色,音品Tonic 律音Top 最高TOS tape operating system 磁带操作系统Total 总,总共Total tune 整体协调,总调谐Touch 触,压,按Touch sens 键盘乐器指触的触感TPD turnout piece delay 分支延时TR tape recorder 磁带录音机TR telerecording 电视屏幕录像TR tracking 跟踪TR transfer 传输,转移TR trick 特技效果Track 曲目号,磁迹,音轨Tracking 寻迹,跟踪,统调Tracking monitor 调校监听Trad 陷波器,带阻滤波器Tramp 三通道功放系统Transfer 转印,转接Transformer 变压器Transpose 转调,变换器,移调Transport 运行,发送Transient 瞬态Transient distortion 瞬态失真Transient response 瞬态反应Transmit 发射Transistor 晶体管,三极管Transponder 转调器,变换器Transposer 变调器Transversal equalizers 横向均衡器Treble 高音,三倍的,三重的Tremold tremor 颤音Tremolo 震音Tremor 颤音,振音装置Triamp 三路电子分音Trick 特技Trig 修饰 Spatializer 声场定位技术SPD speed 调制速度SPDIF sonyphilips digital interface 索尼飞利浦数字接口SPE speaker 扬声器,音箱Special 临时(装置),特设的Specificatin 性能Spectrum 音域,频谱Speech 语言,语音Speed 速度,调制速度Speed select (录音机)带速选择SPG severo pulse generator 伺服脉冲发生器SPH single phase 单相SPL sound pressure level 声压级Split 分割,分配,等信号区SPM spiral modulation 螺旋调制Spot effects 现场效果Spring 弹簧效果,弹簧混响器SPS stereo pitch shift 立体声变调SPSS self program search system 自动节目搜索系统Sport 运动场效果SQ squelch 静噪,噪声抑制(电路)SQ stereo quadraphonic record 四声道立体声唱片Square 广场音响效果Squawker 中音扬声器Squeal 啸叫Squegger 间歇振荡器Squib drivers 电爆激励器SR 遥控操作SR speed ratio 转换速率SR stabilizeation receiver 稳定接收机SRL standard recording level 标准录音电平SRS sound retrieval system 声音归真(恢复)系统,是一种利用双声道产生环绕声场的虚拟环绕声方式。
产品选型手册在线水质分析及过程控制器仪表分册北京洛华科技有限公司Beijing FLOWTECH Electric&Mechanical Ltd.Co.努力,只为更好研发10多年来,我们专注于水分析传感器、流量传感器、监控仪表、测量平台的研制,致力于废水处理、纯水制程、石油化工、电力冶金、制药、造纸、食品及饮料、生物工程等广泛的行业领域提供卓越的产品和服务KF11系列转轮流量传感器■霍尔式脉冲输出,集电极开路NPN,驱动能力强■具有很高的耐化学腐蚀特性■IP68防护等级,适用于恶劣的现场环境■插入式易安装■稳定性好,抗干扰能力强■可靠性好,免维护性能指标产品选型流量测量0102KF11-S10金属流量传感器■插入式易安装■316L 本体,EPDM 密封■适合于高温高压环境■适用管径DN50-DN600■卫生级,适用于食品,啤酒等行业■耐腐蚀性好性能指标应用行业产品选型■啤酒及饮料■化工洗涤及中间体■冷却及供热系统■单晶硅清洗■水处理及再生■泵保护■纯水制程/反渗透/超滤/水过滤紧凑型流量传感器适用于安装在三通管件上,尺寸范围从DN15-DN50(0.5”至2”);设计用于不含固体颗粒,悬浮物等杂质的液体;集电极开漏输出(NPN),稳定的方波信号,直接输送给流量控制器或PLC 高速脉冲口;产品特点性能指标■插入式易安装■PP 本体,EPDM 密封■能够安装在标准的三通件上■适用管径DN15-DN50应用行业■纯水制程/反渗透/超滤/水过滤■冷却及供热系统■供水系统■水处理及再生■泵保护KF11-G10高压型流量传感器高压型转轮流量传感器适用于高压场所,尺寸范围从DN50-DN300(2”至18”);本体/轴均采用SS316L 材质,确保较高的机械强度;适合于金属管道安装,不锈钢直焊座,上下法兰利用螺钉固定,中间用PTFE 垫片密封,保证整体运行的稳定性;产品特点性能指标■可耐压110bar,温度100℃■SS316L 本体/黄铜本体■适用管径DN50-DN300■流速范围:0.3-8m/s ■精度可高达1%■采用高强度哈氏合金轴应用行业■冷却及供热系统■水处理及再生■泵保护流量测量03KF11-W10流量测量04KF11-W10F涡轮流量传感器是一种速度型流量计,适用于粘度低,连续流动的液体;可输出脉冲/4-20m;传感器分普通型,防腐型;产品特点性能指标■精度高■有螺纹连接,卡套连接,法兰连接■适用管径DN6-DN100应用行业■水处理■循环水系统■中间体■CIP 清洗■水处理及再生■农业施肥机及农业灌溉KF11-M700微型流量传感器微型电磁流量传感器没有可动部件,没有机械式磨损,体积小,螺纹连接安装方便,转轮及涡轮无法测量的污水有杂质的介质,可使用此流量传感器,尺寸范围从DN6-DN25;输出脉冲信号可直接输送给流量控制器或PLC 脉冲口;产品特点性能指标■螺纹连接,方便安装■无压损,无磨损■适用管径DN6-DN25应用行业■加药系统■酸碱配比■滴定取样型号KF11-W10(W10F)流速范围0.3-6m/S 管径范围DN6-DN100信号输出脉冲型或电流型线性精度L:1%(全量程)重复性精度R:0.5%(全量程)温度及压力10bar(145psi)@80℃(176℉)过程连接螺纹/卡套/法兰材质不锈钢或PTFE 轴/轴承ZrO2.316L.Hc.Ti/ZrO2供电信号DC 24V 或AC220V(控制器)电缆规格5m 屏蔽电缆线(最长300m)防护等级IP68型号KF11-M700管径范围DN6-DN25电极材料316L/Hb/Hc/Ti/Ta/Pt 线性精度L:1%(全量程)介质电导率≧20us/cm 内衬PVDF 输出信号脉冲、频率流速范围0.3-10m/s 工作温度-5℃∽80℃工作压力0.6∽1.0MPa 电气连接5芯航空插头电源供电DC 24VKF11-W10FKF8100流量控制器■全数字化设计,抗干扰能力强■SMT贴片工艺,集成度高,功耗低■集变送功能和控制功能于一体,可实现流量批次控制■可实现盘装、壁挂、一体式安装,满足复杂现场安装要求■循环式菜单,操作方便性能指标型号控制器显示•大屏LCD显示•瞬时流量、累计流量、报警提示、4-20mA输出状态•循环式菜单,密码保护输入•0-2KHz脉冲信号•幅值3-12V测量范围0-10KHz(n<2000RPM)测量精度线性精度:1%重复性精度:0.5%输出•光电耦合隔离4-20mA输出•脉冲输出•开关量(两组常开触点)•RS485(自由通讯口)坏境要求温度:-20℃∽+70℃(-4∽158℉)湿度:相对湿度90%以下,无水汽凝结现象无强电场、强磁场环境(远离大型变频器,大型电机等)无明显振动场所无腐蚀性气体场所继电器AC2203A,可编程防护等级IP65接线方式三线制或四线制供电系统DC24V功率3瓦(屏点亮最大消耗功率)仪器尺寸96X96x60mm开孔尺寸93X93mm重量0.25KG应用行业•纯水制程/反渗透/超滤/水过滤•冷却及供热系统•供水系统•水处理及再生•泵保护流量测量0506电磁流量计KF700型电磁流量计可广泛适用于工业液体的测量,可测量电导率值极小的液体,可测量酸,碱,盐等强腐蚀性及固液两相的体积流量;口径范围为DN10-DN2000;根据不同安装环境,可分法兰型、螺纹型、夹持型、高压型等。
MX2H-2HC高速计数输入模块硬件手册BOM:M17060012 版本:A02 归档日期:2017.5.10感谢您选用麦科电气技术有限公司开发生产的可编程控制器(PLC)。
在安装、使用本产品前,请您仔细阅读本手册。
本手册介绍了可编程控制器MX2H-2HC的电气规格、功能规格、安装配线和维护等部分说明,以及常见问题答疑等。
让您能清楚地掌握本产品的特性以及丰富的功能。
若需要更详细的产品资料,可参考我公司发行的《MX系列可编程控制器用户手册》和《MX系列可编程控制器编程手册》。
MX2H-2HC是MX2H系列PLC扩展模块中的一种,支持2路200K的高速输入和4路普通输出,主要是对MX2H系列主模块高速输入计数器的补充。
MX2H-2HC的计数频率比PLC内置的高速计数器的计数频率高,而且它可直接进行比较和输出。
高速输入作计数脉冲信号使用,普通输出作硬件置位使用。
主模块通过FROM/TO指令访问本扩展模块内寄存器的BFM单元,也可使用“MOV Un.b ××”访问扩展模块内寄存器的BFM单元。
各种计数模式可用PLC命令进行选择,如1相或2相,16位或32位模式等。
只有这些模式参数设定之后,MX2H-2HC模块才能运行。
输入信号源必须是1相或2相编码器。
可使用5V、12V、24V电源,也可使用禁止计数输入信号(DIS)和复位输入信号(PRE)。
输入配线有源型或漏型两种模式可供选择。
MX2H-2HC硬件高速计数输入模块有4个输出点YH0(CH1/ CH2)、YH1(CH1/ CH2),当计数值与设定值相等时,相对输出将执行。
输出晶体管是被单独隔离的。
MX2H-2HC的扩展电缆接口和用户端子均有盖板,打开各盖板后便可露出扩展电缆接口和用户端子,如图1所示。
I/O扩展模块以及各种特殊功能模块(如4AD/4DA/4TC/4PT/8TC/2HC/2PG 等模块),统称为扩展模块。
PLC主模块每次上电时,会自动检查一次已接入的所有扩展模块,并分别对这些扩展模块端口进行“编号”,用户无法干预或更改其编号结果,除非改变模块的连接顺序。
VEX140 Horizontal HCEwith EXact2 controlProduct information........................................Chapter1 + 6Mechanical assembly.....................................Chapter2 + 3Electrical installation.......................................Chapter4Maintenance...................................................Chapter 5Original instructions3004498-2019-08-28VEX140H_HCEEXHAUSTO A/S Odensevej 76DK-5550 LangeskovTel. +45 65 66 12 34Fax: +45 65 66 11 10********************www.exhausto.dk1.Product information1.1.Designations used in these instructions.............................................................61.1.1.Simplified diagram............................................................................................61.2.Application.............................................................................................................71.3.Location requirements..........................................................................................71.3.1.Space requirements.........................................................................................71.3.2.Requirements for underlying surface...............................................................71.3.3.Condensation outlet.........................................................................................71.3.4.Requirements for duct system.........................................................................81.4.Description.............................................................................................................91.4.1. Construction of the VEX unit...........................................................................91.4.2.Parts of the VEX unit......................................................................................101.5.Principal dimensions. (11)2.Handling2.1.Unpacking.............................................................................................................132.2.Transport..............................................................................................................132.2.1.Passage through openings............................................................................142.2.2.Internal transport with reduced weight.. (15)3.Mechanical assembly3.1.Installation............................................................................................................173.1.1.Installation directly on floor.............................................................................173.1.2.Installation on mounting base........................................................................173.2.Condensation outlet............................................................................................173.2.1.Establishment of condensation outlet (17)4.Electrical installation4.1.Electrical installation (19)5.Maintenance, hygiene and servicing5.1.Operating readings via the HMI panel................................................................205.2.Maintenance.........................................................................................................205.2.1.Overview of maintenance intervals................................................................205.3.Hygiene (VEX100VDI only)..................................................................................215.4.Servicing and cleaning........................................................................................215.4.1.Filter change..................................................................................................215.4.2.Cleaning the fans...........................................................................................215.4.3.Cleaning the heating coils..............................................................................225.4.4.Cleaning the crossflow heat exchanger (22)6.Technical data6.1.Weight, corrosion class, temperature ranges, etc............................................246.2.Panel filters...........................................................................................................256.3.Electric heating coil ............................................................................................266.4.Capacity diagram.................................................................................................276.5.EC Declaration of Conformity.............................................................................276.6.Ordering spare parts. (27)2/326.7.Environmental declaration (28)3/32Symbols, terms and warningsProhibition symbolFailure to observe instructions marked with a prohibition symbol may result in serious or fatal injury.Danger symbolFailure to observe instructions marked with a danger symbol may result in personal injury and/or damage to the unit.ScopeThis instruction manual is for use with EXHAUSTO VEX-type air handling units.Please refer to the product instructions regarding accessories and extra equip-ment.The instructions must be fully observed to ensure personal safety and to protect the equipment and ensure its correct operation. EXHAUSTO A/S accepts no liabil-ity for accidents caused by equipment not used in accordance with the manual’s instructions and recommendations.Supply air/extract airThis instruction manual uses the following terminology:●Supply air ●Extract air ●Outdoor air ●Exhaust airAccessoriesThe confirmation of order states which accessories are delivered with the VEX unit.DefinitionIn the type designation R stands for Right, indicating that the supply air is to the right of the unit, as seen from the operating side. Supply air to the left is designa-ted with L for LeftProhibited usesThe VEX unit is not to be used to transport solid particles or in areas where there is a risk of explosive gases.No duct connectionIf one or more of the spigots is not connected to a duct: Fit a protective net to the spigots with a maximum mesh width of 20mm (in accordance with EN294).Lock the air han-dling unit during operationThe VEX unit must always be locked during operation:●Use the cylinder lock in the han-dle. Remember to remove the key from the lock.●Or use a padlock. Use the han-dle’s built-in padlock fixture.LockPadlock fitting4/32Rating plateThe VEX unit rating plate shows:●VEX unit, type (1)●production number (2)NB Always have the production number ready when contacting EXHAUSTO A/S.Choose the correct documentation for the task...Find your information.5/321. Product information1.1 Designations used in these instructions 1.1.1 Simplified diagram6/321.2 ApplicationComfort ventilationEXHAUSTO VEX is used for comfort ventilation tasks.Operating temperature range for the unit – see section "Technical data".Prohibited usesThe VEX unit is not to be used to transport solid particles or in areas where there is a risk of explosive gases.1.3 Location requirementsPositioningThe unit is designed for indoor fitting. The unit can be ordered for outdoor fitting, in which case it is provided with a roof (accessory VEX100OD).1.3.1 Space requirementsThe drawing below indicates how much space is needed for opening the doors and servicing the unit, e.g. changing filters, cleaning, servicing, etc.R D 10182-02NBFor servicing, the VEX must have a free height of at least 300 mm above the con-nection box.1.3.2 Requirements for underlying surfaceWhen fitting the unit directly to an existing surface - i.e. without using the mounting base (accessory) - the surface must be:●flat●level (+/- 3 mm per metre)●hard●resistant to vibration1.3.3 Condensation outletA condensation outlet must be installed in the immediate vicinity of the unit. See also "Mechanical assembly" section.7/321.3.4 Requirements for duct systemSilencers The duct system must be fitted with silencers specified by the Project Manager,which meet the requirements of the operating area.Bends A duct bend may be fitted immediately after the unit, because the airflow in thespigot has a uniformly moderate speed profile, which results in negligible systempressure loss.Insulation The duct system must be insulated against:●condensation●sound leakage●heating/cooling lossesCondensation Condensation in the ducts may occur when the exhaust/outdoor air has high hu-midity. EXHAUSTO recommends a condensation outlet is also fitted at the lowestpoint in the ducts.Outdoor air intake The outdoor air intake must be dimensioned with sufficiently low airflow to prevent rain and snow being drawn into the duct system.No duct connection If one or more of the spigots is not connected to a duct: Fit aprotective net to the spigots with a maximum mesh width of 20mm.8/321.4 Description1.4.1 Construction of the VEX unitThe following drawings show an overview of the construction of left and right-handmodels of VEX units (shown without doors).RD10181-02RD10224-029/321.4.2 Parts of the VEX unitCabinet The inside and outside of the cabinet are made of Aluzinc® The cabinet has been insulated with 50 mm mineral wool.Fans The unit contains two centrifugal fans with backward curved blades for extract air and supply air.Crossflow heat ex-changer The crossflow heat exchanger in the unit is mounted with a modulating bypass damper. The crossflow heat exchanger can be removed for cleaning.Filters The unit includes integral panel filters for both extract air and supply air.10/321.5 Principal dimensionsVEX140H, Left The following drawing gives the principal dimensions:NNMRD133-2NB The drawing shows all of the spigot positioning options.* Allow a distance for service in front of the unit equivalent to the unit depth.** Allow a min. of 300 mm free height for service.VEX140H, RightThe following drawing gives the principal dimensions:NMM R D 10304-021,1,A 2,1,ANBThe drawing shows all of the spigot positioning options.* Allow a distance for service in front of the unit equivalent to the unit depth.** Allow a min. of 300 mm free height for service.2. Handling 2.1 UnpackingSupplied compo-nents The following components are supplied:●VEX unit●Supplied accessories (as indicated in the checklist on the front page of the in-structions).Packaging The unit is delivered on a disposable pallet and packed in clear plastic.NB Once the plastic has been removed, the unit must be protected against dirt and dust:●The covers on the spigots must not be removed until the spigots areconnected to the ventilation ducts.●Whenever possible, keep the unit closed during fitting.The unit should be cleaned before it is used.Once the VEX unit is fitted, it must be checked and thoroughly cleaned. All dust, debris and metal shavings must be vacuumed up.2.2 TransportTransport Transport the VEX unit on the disposable pallet. Do not lift it with the spigots or connection box.Transport methods Transport the VEX unit in one of the following ways:2.2.1 Passage through openingsHeight VEX height is 1127 mm + any base spigot (+62 mm).Width The list (below) shows how wide the opening has to be for the unit to pass through:*) Measurements are based on the exact dimensions of the VEX unit.2.2.2 Internal transport with reduced weightRemoving the serv-ice doors To remove the service doors:●Open both doors.●Using a small punch or similar tool, knock the pin out of the top of the doorhinges (A), and lift the doors off.RD1247-2Detail AAWeight reduction The weight can be reduced during transport by removing service doors, fans and crossflow heat exchanger. The table below shows the how much weight can bereduced by removing the various parts.To remove the fanunitDismounting See section "Maintenance" for instructions for dismounting fans and crossflow heat exchanger and for removal of filters.3. Mechanical assembly3.1 InstallationDescription It is important that the VEX is installed on a level surface, as this affects the col-lection and draining of the condensate.3.1.1 Installation directly on floorThe requirements for the floor surface must be met, see the section entitled "Re-quirements for underlying surface".NB After installation, check the VEX unit is completely level.3.1.2 Installation on mounting baseThe EXHAUSTO mounting base enables the VEX unit to be installed correctly. Thebase is equipped with adjustable levelling screws, so that the air handling unit can befitted horizontally on a surface that is not level ( +/- 20 mm per metre). See the sepa-rate instructions for installing the mounting base.3.2 Condensation outletConnection of the condensation outlet must be made by an au-thorised plumber.Drain the condensation outlet into a floor gully or similar. Thecondensation outlet must be fitted with a water trap. See below. Risk of frost Where there is a risk of frost: It is recommended to protect thecondensation outlet against frost damage. Fit a SIPHONE electri-cal heat tracing device on the outlet before the pipes are insula-ted. For fitting, see the device’s fitting instructions.3.2.1 Establishment of condensation outletLocation The following two drawings show examples of how the drain from the condensa-tion outlet can be established and the correct dimensions for the water trap:Solution with si-phon water trap (ac-cessory)The siphon water trap is easy to install and service.R D 13442-01Solution with HT pipe Use HT pipe (HT, DN32, DIN4102), if the above solution is not employed (not sup-plied by EXHAUSTO).R D 10185-02NB:If the VEX is erected on a mounting base, this will allow sufficient free height for installing a water trap.4. Electrical installation4.1 Electrical installationSee the attached instructions “Guide to Electrical Installation of VEX140 HCE with3004498-2019-08-28Electrical installation5. Maintenance, hygiene and servicing5.1 Operating readings via the HMI panelHMI panelRefer to the “EXact2 Control System Basic Instructions for VE100/100CF” for in-structions on accessing Menu 2 "Operation displays" via the technician menu (ac-cess code 1111) to check the unit’s operating status.5.2 Maintenance5.2.1 Overview of maintenance intervalsThe following chart details the recommended maintenance intervals for the VEX.based on normal operation. EXHAUSTO recommends maintenance is adjusted to suit the actual operating requirements.*Filters Only use original EXHAUSTO filters●The provided filter data (section "Technical data") are based on the use of original EXHAUSTO filters●Eurovent certification is only valid if original filters are used.●Use of non-original filters may cause leakage in the VEX unit, impair filter function and cause an extraordinary pressure drop.●EXHAUSTO recommends that you register the filter replacement date to en-sure filters are replaced at the correct intervals.3004498-2019-08-28Maintenance, hygiene and servicing5.3 Hygiene (VEX100VDI only)VDI6022 air hygiene standard To ensure that the VEX100 meets the requirements of the VDI6022 hygiene standard, its design ensures that:●bacterial growth and dirt accumulation are minimal●conditions for cleaning are optimumFilter ePM1 55%The outdoor air side of the unit must as a minimum be fitted with an ePM1 55% filter(F7) to meet VDI 6022 requirements.5.4 Servicing and cleaning5.4.1 Filter changeDisconnect power at the isolation switch before opening the door.Pull the filters out. Remember to check the flow direction - see the arrows on the fil-ter.Discarded filters must be stored immediately in sealed plastic bags and disposed ofresponsibly.Filter change in menu 8.1After filter change (timer operation only): Go to menu 8.1 in the EXact control system and select "Yes" next to filter change to reset the operating days counter.5.4.2 Cleaning the fans5.4.3 Cleaning the heating coils5.4.4 Cleaning the crossflow heat exchangerDismount the Tice sensor from the heat exchanger bracket (see photo step 10).Remove the crossflow heat exchanger. Note the weight of the heat exchanger, seetechnical data – min. two persons for lifting.Press the release button on the bypass motor and turn the damper with the louvres in openposition.Do not activate the release button on the bypass motor while it isdismounted, as this will alter the position of the motor comparedto the damper.Clean the heat exchanger by flushing with hot water or by pressure washing. Max. water temperature. 90℃.Mount the bypass motor. The damper must be in open position (louvres fully open), as for dismounting.Re-insert the plug for the bypass motor.6. Technical data6.1 Weight, corrosion class, temperature ranges, etc.WeightVEX total weight190 kgDoors 2 x 13.5 kgCrossflow heat exchanger27 kgFan unit 2 x 15.5 kg105 kg VEX for transporting into building (without doors, heat exchangerand fan unit)Corrosion classCorrosion class Corrosion class C4 in accordance with EN ISO 12944-2Temperature rangesOutdoor air temperature-40ºC to +35℃Ambient temperature-30ºC to +50ºCAt temperatures below -25˚C (with outdoor installation), use of a thermostaticallycontrolled heater in the automated control box is recommended.HMI-panelIngress protection IP20Ambient temperature0°C - +50°CAt temperatures below 0˚C the display may react more slowly than usual.Fire thermostatsCut-out temperature, BT7070°CCut-out temperature, BT5050°CCut-out temperature, BT4040°CMax. ambient temperature, sensor250°CAmbient temperature, thermostat housing0°C - +80°CSensor length125 mmIngress protection IP40Temperature drop before reconnection possible min. 15°KMotor damperA maximum of two LSFR dampers or four LSA/LSF dampers may be connected.6.2 Panel filtersFinal pressure drop For the final pressure drop over the filter, the lower of the following two methods is recommended.●Final pressure drop = 3 x initial pressure drop●Final pressure drop = initial pressure drop + 100 Pa6.3 Electric heating coilElectric heating coilDiagram - tempera-ture rise The diagram below can be used to determine the air temperature increase at agiven airflow and electric heating coil size.Examples: Pressure drop across electric heating coilAt airflow of 1800m 3/h:●HCE 7.2 kW : 10 Pa ●HCE14.4 kW: 15 Pa6.4 Capacity diagram15003000Air flow rate5001000q v [m 3/h]q v [l/s]54001080018003600501801003602007203001080Recommendationcapacity with the EXselect calculation program, available on the EXHAUSTO web-site.6.5 EC Declaration of ConformityThe document is located in the door of the VEX unit. It is also available on the EX-HAUSTO website by searching under the document or order number.6.6 Ordering spare partsFind production numberWhen ordering spares, please state the relevant production part number. This will ensure that the correct parts are delivered. The production number is given on the front of the VEX guidelines and on the VEX rating plate.Contact:Contact your local EXHAUSTO office service department to order a spare part.Contact information is given on the back cover of these instructions. See also the"Layout" section for an overview of the position and designation of parts in theVEX.6.7 Environmental declarationEnvironmental doc-umentation The unit can be disassembled into individual product parts when outworn and in need of disposal.Percentage weight3004498-2019-08-2831/32。
mtr11温控器说明书一、产品简介MTR11温控器是一款高性能的温度控制器,适用于各种工业和家庭环境。
本产品采用先进的微处理器控制系统,具有高精度、高稳定性、易于操作等特点。
通过对温度进行精确控制,实现对设备的自动化管理,有效提高设备运行效率和降低能耗。
二、功能特点1.精度高:MTR11温控器采用进口传感器,确保测量精度在±0.1℃以内。
2.控制范围宽:适用于-20℃至120℃的温度控制需求。
3.多种输入信号:支持热电偶、热敏电阻、电流等多种输入信号。
4.输出方式灵活:可选择电压、电流、PID调节等多种输出方式。
5.手动/自动切换:可根据需要切换手动控制和自动控制模式。
6.上下限报警:设置温度上下限,当温度超出范围时,自动发出报警信号。
7.通讯功能:支持RS485/RS232通讯接口,方便与上位机连接。
三、使用方法1.安装:将温控器安装在需要控制温度的设备上,确保传感器与被测物体充分接触。
2.接线:根据设备需求,连接输入信号、输出信号和电源。
3.设定参数:使用配套的上位机软件或按键设置温度控制参数,包括温度上下限、PID参数等。
4.启动运行:接通电源,根据需求选择手动或自动控制模式。
四、注意事项1.请勿在温控器表面涂抹油脂或粘贴污渍,以免影响散热。
2.避免在高温、潮湿、易受腐蚀的环境中使用。
3.定期检查传感器连接是否牢固,如有松动可能导致测量误差。
4.长时间不使用时,请将电源切断。
五、故障处理1.若温控器无法正常启动,请检查电源线是否接好,电源是否正常。
2.若温度控制不准确,请检查传感器连接是否良好,设置参数是否合理。
3.若温控器发出报警信号,请根据报警原因进行处理,如调整温度设定值、检查设备运行状态等。
六、售后服务1.产品保修期为一年,保修期内免费维修。
2.用户提供技术支持和故障解答。
3.定期对产品进行升级更新,提高用户体验。
总之,MTR11温控器具有出色的性能和便捷的操作,能够满足各种温度控制需求。
6/11系列_泛用车床控制器操作手册匯出日期:2023-05-10修改日期:2023-01-182023/05/10, 21:041 适用机型本车床操作手册适用於新代泛用型控制器,包含:11TA、11TB、6TA、6TB。
• a.b.c.d.e.f.g.h.i.j.k.2 功能键与系统概论2.1 主画面介绍画面元件说明目前工件坐标系加工档及加工行号画面标题日期时间资料输入提示状态模式警报功能键选择2.2 功能键树状图2.2.1 八键系统2.2.2 五键系统2.3 机台座标•••••••••••••••••••路径F1机台座标 (五键、八键系列)G1加工资讯 (10+8键系列)说明针对目前机台之座标显示进行操作。
显示常用之加工资讯。
使用快速键【POS 】可快速切换至此页面。
2.3.1 画面说明座标显示本画面同时显示四组座标。
可透过「座标切换」功能,切换目前大座标的显示座标。
F(进给速率)显示使用者设定之进给速率。
显示机台的实际进给速率。
显示使用者设定之进给速率百分比。
S(主轴转速)显示使用者设定之主轴转速。
显示机台的实际主轴转速。
显示使用者设定之主轴转速百分比。
加工时间显示加工时,该加工程序已执行之时间工件数显示该加工程序已加工之次数。
搭配Pr3804的设定,程序每次执行到设定的M 码时,工件计数器会自动加一,且单件加工时间归零,当到达需求工件数後,会自动进入暂停状态。
T(刀号)显示目前加工所使用到的刀具号码及刀具补正编号。
2.3.2 座标切换路径••••••••••• a.b.i.ii.iii.•••••••• a.b.c.••••••• a.b.c.五键、八键系列:F1机台座标→F1座标切换 10+8键系列:G1加工资讯→F1座标切换说明此按键可切换目前机台画面所显示的机台座标排序。
2.3.3 1/2座标路径五键、八键系列:F1机台座标→F2 1/2座标10+8键系列:G1加工资讯→F2 1/2座标说明将相对座标的数值除以2。