告警代码告警号告警星级告警内容
7606*
TRX is stuck in waiting for system information state 7606**The transmitter output power has dropped at least 3 DB
7606**The synthesizer in remote tune combiner is faulty.
7606**Antenna connection faulty.
7606**
Failure detected during TRX configuring
7606**ERxx DDU module has detected VSWR above major limit at antenna A
7606**The tuning of a cavity has failed in remote tune combiner.
7606**There is disturbance in the serial DL bus or bus is broken
7606**The transmitter output power is too low.
7606**The transmitter output of TRX is overdriven.
7606**The RF transmitter frequency hopping synthesizer 1 is not
7606**BOI detected that connection to TRX is lost.
7606**ERxx DDU module has detected no Tx power at TxA input
7606**ESMA System module has lost connection to EXxx TRX module
7606**Two or more ERxx DDU modules detected in 2- or 4-way combined sector.
7606**EXxx TRX module has no combiner ERxx DDU or ECxx RTC module present.
7606**ESMx System module has lost connection to RF module
7606**EXxx TRX module has lost connection to ERxx DDU module
7606**EXxx TRX module Tx power is less than minimum at DPC
7606**
EXxx TRX module Tx power overdriven at DPC
7606**EXxx TRX module incoming frame clock FCLK missing
7606**FBUS HW failure.
7606**Interface problems between O&M and DSP SW.
7606**Optical link configuration error
7606**Remote tune combiner initialisation failed.
7606**RF module detected VSWR above major limit
7606**TRX object allocation failed in RF module
7606**REOCA optical module reported incoming clock failure,
7606**Hardware incompatibility detected during EXxx TRX module
7606**Invalid RF module hardware configuration detected
7606**The reflected power of remote tune combiner is too high
7606**PDU control has switched off ECxx RTC Module
7606**Logical TRX object has missing transmission time slot 7606
7606**Rx Uplink path not working in ESMx System Module
7606**2nd branch LNA in dual variable gain duplex unit is faulty 7606**Tuning carrier is not detected in remote tune combiner
7606**
Failure in 26 MHz clock input.
7606**Performance is degraded in 2nd branch dual variable gain duplex unit
7606***ECxx RTC module has detected VSWR above major limit at antenna 21 02 00 B6 01 00
7606***
ERxx DDU module has detected no Tx power at TxB input
站型告警名告警原因
ULTRASITE载频在等待系统信息状态基站与BSC建立LAPD链路后等待BSC发指令进入WO状态,BSC发出指令后基站无响应就一直停在这个状态
载波输出功率低于正常值至少3db 1、载波本身发射功率低,2、载频发射单元故障,3、载频连线
远程调谐合路器的合成器故障。
ULTRASITE天线连接失败1、连线故障 2、载频故障 3、基带单元故障
ULTRASITE载频配置失败1、载频故障 2、BSC数据问题
a A 合路器检测到A口驻波比高于最
大门限
1、天馈驻波比过高,
2、载频故障
ULTRASITE RTC合路单元腔体调谐失败合路器本身腔体调谐故障
ULTRASITE DL bus总线故障,DL bus总线有
扰码或损坏
1、BUS线故障,
2、BUS线有干扰,
3、基
站硬件数据与实际不匹配
载波输出功率过低载频故障
ULTRASITE载波输出功率过载载频故障
发射机跳频合成器故障发射机跳频合成器失锁
ULTRASITE BOIA检测到与载频连接丢失载频与主控单元失去连接,1、载频在有数据没闭锁的情况下被拨出 2、基站现场是否有载频硬件 3、载频对应的背板故障,4、基带单元故障
FLEXI合路器检测不到A口有功率输出合路器功率故障
FLEXI系统模块和载频之间的连接丢失检查该载频是否断电,载频重起也出此告FLEXI该扇区的合路次数不一致,连线不一致,衰减不同,功率不一致FLEXI载频未检测到ERGA/Ecxx载波未检测到合路器
MCPA系统模块和RF连接丢失RF掉电,尾纤故障
FLEXI 系统模块和合路器之间的连接丢
失
检查为该合路器供电的载频是否断电或重
起.之间的BUS连线是否正常
FLEXI 数字功率控制器检测到载频功率
低于14.5dBm
载频DPC处小区最小值
FLEXI 数字功率控制器检测到载频功率
高于额定功率2dBm
载频DPC超值
FLEXI载频缺少FCLK引入的时钟FCLK时钟丢失
ULTRASITE FBUS总线故障开跳频时,同BTS设备有隐性故障ULTRASITE O&M和DSP软件接口故障基带板故障
MCPA光链路配置错误基带总线同步故障
ULTRASITE RTC初始化失败RTC初始化失败
MCPA驻波比告警驻波比超过1.9触发告警
MCPA载频分配失败功率不匹配或者带宽超限FLEXI光模块报告内部时钟故障内部时钟故障
FLEXI载频硬件不兼容频带不一致或者是设备吊死MCPA检测到无效的RF模块硬件配置RF模块与频段不匹配告警
MCPA RTC反射功率过高因ULTRASITE无VSWR监测器,此告警代表驻波有问题
FLEXI合路器电源开关关闭人为关闭,故障关闭传输时隙丢失传输时隙分配故障
MCPA 接收上行路径在ESMX系统模块不
工作
接收上行路径不能正常工作;BTS不能处理
以下2种情况,要么不能电话或切换)
ULTRASITE DVGx单元的第二支路的LNA故障DVGA低噪单元故障ULTRASITE RTC中没有调谐载波未检测到载波,RTC亮黄灯
ULTRASITE
26MHz时钟输入故障26MHz时钟输入出现故障ULTRASITE DVGx单元的通道性能恶化双工器中两路通道性能恶化RTC模块检测到天线驻波比值超
过门限天馈故障
FLEXI DDU的TXB口没有输入功率
载频故障
告警处理
1、重启BCF,
2、带传输集成基站数据
1、倒换载频,
2、检查连线
1. 检查TSxx与合路器单元的电缆,如果故障,更换电缆
2. 如果电缆完好,倒换TSxx单元。更换故障单元。
1. 查看是否有7705告警,如果有,并且故障的TRX都是属
于一个BB2x单元。那么检查BCF的软件版本,如果低于
CMX3.3-2,那么升级BCF软件。
2. 如果告警依然存在,倒换故障的TSxx单元,必要要时更
换故障单元。
3. 检查TSxx的频点配置是否与硬件一致,更改错误
1、检测天馈,测试驻波比及回波损耗
2、更换载频
1、重启BCF
2、更换合路器腔口位置
3、更换合路器
1、检查BUS线
2、重新集成硬件数据
3、检查载频及合路器是否故障
更换TSGB
更换TSGB
关闭BB跳频后开启-更换故障载波
1. 检查BTS的配置,插拔BB2x单元
2. 如果告警依然存
在,插拔TSxx单元 3. 如果告警依然存在,更换TSxx
A口无输出功率,检查对应的连线单元
检查该载频是否断电,与主控BUS线连接是否正常
检查小区内载波连线的合路次数是否相同
核查载频连线及对应合路器的BUS线,如无故障更换对应的合路器设备
检查该RF是否断电,与主控BBU光路连接是否正常
载频与合路器失去连接,重启BCF恢复
载频DPC处小于最小值,建议更换载频
载频DPC超值,派单更换
建议检查载频到系统模块的BUS连线,及系统模块BUS接口.如BUS正常建议更换载频
关闭BB跳频后开启-更换报警载波的BB2F后重启BCF观察-依次更换板件
1. 重启TRX
2. 如果故障还存在,更换BB2x单元
远端关电,重启BCF;机架= 01(RF基带总线同步错误)
机架= 02(RF基带总线配置错误)如果警报持续存在,更
换RF模块
1. 重启BCF
2. 如果告警还存在,更换RTC
1、测试驻波比(驻波比过高,核查天馈线及各接口单元)
2、检查合路系统
射频模块分配失败,首先检查功率是否匹配,是否超过带宽限制,RF模块是否脱机吊死
R代表远端,先远程复位观察-更换远端EOCA
载频硬件不兼容,如果是Ecxx合路器建议远程断电复位后重启
检查RF模块与频段是否匹配,更换RF模块
1、室分的话检查电桥是否击穿
2、宏站测量驻波是否驻波正常,更换对应RTGA
控制EC的PDU开关被关闭,登远程复位,重启BCF
1、还原载频时隙
2、删除载频过程时隙丢失,还原信令25-0上载频后恢复(同步开启情况)
重启BCF或者重新远程配置硬件数据库
1. 第一支路没有使用 2 激活第一支路或更换DVxx
对换载波观察-更换故障的RTC
1、如果所有的TRX都有这个告警,更换BOI单元
2、如果只是一个TRX有这个告警,更换BB2x单元。
1、核查是否存在较强干扰导致告警,无误更换DVGA
2、室分检查馈线是否拧紧,无误更换DVGA
检查馈线,天线
1.先检查连接TXB口的RF连接线是否完好,更换告警消去
2.上下倒换载频,看告警是否跟问题载频的移动而转移,如果跟着转移,则需要更换载频;如果不转移,则需要更