新渡米 新 替 清洗世界 Cleaning World 第26卷第1 1期 2010年11月
文章编号:1671—8909(2010)11—0035—04
660 MW超一超临界机组
给水加氧技术的应用
王金玲
(1.华中科技大学,湖北武汉430074;2.大唐信阳华豫发电有限责任公司,河南信阳464000)
摘 要:介绍了信阳电厂3号机组的给水加氧工作过程。加氧实施后,水汽系统铁含量比加氧
前有明显降低。超一超临界机组的给水加氧处理可大大提高机组的安全性和经济性。
关键词:超一超临界机组;给水处理;加氧
中图分类号:TP278 文献标识码:B
Application of oxygen supply technique for 660MW ultra-supercritical units
WANG Jinling ,
(1.Huazhong University of Science and Technology,Wuhan,Hubei 430074,China; 2.China Datang Xinyang Power Limited Liability Company,Xinyang,Henan 464000,China) Abstract:To introduce working process added oxygen of water supply and water system of the unit 3 Xinyang Power.Content of iron is a significant reduction after the implementation of added oxygen than before that added oxygen.Add oxygen treatment for water supply of ultra supereritieal units can greatly improve the safety and efficiency of unit. Key words:ultra—supercritical unit;water supply treatment;add oxygen
2010年第5期 内蒙古石油化工 107
浅谈电厂锅炉补给水防腐问题和加氧处理技术
田国强 ,张瑞锋 ,田建英
(1.北方联合电力呼和浩特市热电厂;2.内蒙古电力勘察设计院)
摘要:结合当前电厂锅炉在补给水处理环节中防腐问题进行论述,重点介绍加氧处理技术,并提
出了相应的改进措施和建议,以供大家探讨。
关键词:锅炉;补给水;防腐;加氧处理
中图分类号:TK224.9+2 文献标识码:A 文章编号:1006--7981(2O1O)O5一O107一O1
规范电厂锅炉补给水处理工作,不但可以有效
防止和减少锅炉结垢、腐蚀及其蒸汽质量恶化而造
成的事故,而且有利于促进电厂锅炉运转的安全、经
济、节能、环保。由此可见,电厂锅炉补给水的处理在
锅炉整体运转中起着至关重要的作用,直接影响着 机组的安全、健康和平稳运行,但其中防腐问题需要 我们在电厂锅炉补给水处理中加以注意,并在实践 工作之中不断研究探索其解决之道。
电厂锅炉在补给水过程中的防腐蚀问题,关系 着锅炉的安全运行,关系着锅炉能否发挥出设备厂
家设计的相关指标和标准,关系着电厂的运行成本 和作业效率。因为,电厂锅炉如在补给水这一工艺环
节处理不当,容易使锅炉内体产生腐蚀性的化学物 质,其在锅炉内沉积或附着在锅炉管壁和受热面上,
会进而形成难熔和阻障热传导的铁垢,而且腐蚀会
造成锅炉管道的内部壁体出现点坑,导致阻力系数
的变大,管道腐蚀到一定程度,会产生管道爆炸的安 全生产事故,给企业和国家的财产造成不必要的损
失。目前,针对这一问题主要有以下几种解决办法。 1除氧防腐 目前,除氧防腐的途径主要有三种,一是通过物
理的方法将水中的氧气排出;二是通过化学反应来
排除水中的氧气,使含有溶解氧的水在进入锅炉前 就转变成稳定的金属物质或者除氧药剂的化合物,
从而将其消除,常用的有药剂除氧法和钢屑除氧法
等;三是通过应用电化学保护的原理,使某易氧化的 金属发生电化学腐蚀,让水中的氧被消耗掉,达到除
应用能源技术 2012年第9期(总第177期)
doi:10.3969/j.issn.1009—3230.2012.09.007
锅炉给水加氧处理技术在1000MW机组上的应用
郭春荣
(神华广东国华粤电台山发电有限公司广东台山529228)
摘要:文中介绍了给水加氧处理原理,详细介绍了神华广东国华粤电台山发电有限公司 6号机组给水加氧转换过程、转换过程中各项水质指标的变化情况以及转换过程中存在的问 题,对加氧运行控制方法和加氧运行效果进行了总结。 关键词:给水加氧处理;IO00MW机组;氧量;铁含量 中图分类号:TK229.3.4 文献标志码:B 文章编号:1009—3230(2012)09—0028—05
Application of Boiler Feed Water Oxygenated Treatment
Technology in 1 000MW Units
Guo Chun—rong (Shenhua Guangdong Guohua Yuedian Taishan Power Generation Co.,Ltd,Taishan 529228,China)
Abstract:The principle of feed water oxygenated treatment was described in this paper,adding the detailed description of conve ̄ion process of feed water oxygenated treatment,variation of water quMi ̄indexes and the problems existing in the conversion process of the No.6 unit of Shenhua Guangdong Guohua Yuedian Taishan Power Limited Company.The control methods and effect of oxygenated operation was also summarized. Key words:Feed water oxygenated treatment;IO00MW units;Oxygen content;Iron content
给水加氧
给水加氧处理是20世纪70年代发展起来的锅炉给水处理技术,它与给水除氧截然相反,是在高纯度的锅炉给水中加入适量的氧化剂(通常为气态氧),同时加入微量的氨进行给水水质调节,这样可以进一步减少机组水、汽和热量损失,降低热力系统的结垢、腐蚀和积盐速率,提高机组整体运行的经济性和安全性,延长凝结水精处理混床的运行周期,降低系统的含铁量,全面提高化学监督管理水平。
1.给水加氧原理
给水加氧处理(简称为OT)是指从凝结水精处理混床出口和除氧器出口加入氧气、氨,在微碱性的高纯度水中,氧气能够使碳钢表面形成双层氧化膜,一层是紧贴碳钢表面的磁性氧化铁(Fe3O4),表面一层是以Fe2O3为主的阻挡层。在高温流动的水中致密Fe2O3溶解度很低,起到防止碳钢腐蚀的作用。金属表面氧化膜层要能起保护作用,必须具备下面两个条件:一是氧化物层必须是难溶的、无裂缝和无孔的,金属氧化成氧化物的速度,即金属的溶出速度要小,不至于因此影响到机组的使用寿命;二是若因运行中的机械或化学原因,损坏了氧化膜层,则必须有修复这些损坏部位膜的条件和能力。
1铁氧化膜的形成机理 给水全挥发性处理时,在纯水中与水接触的金属表面覆盖的铁氧化物层主要是Fe3O4。在Fe3O4层形成过程中,由金属表面逐步向金属内部氧化生成了比较致密的内伸Fe3O4薄层,Fe3O4层从钢的原始表面向内部深入。铁素体转化为Fe3O4的内伸转变是在维持晶粒形状和晶粒定位的情况下完成的。Fe3O4层呈微孔状(1%~15%孔隙率),沟槽将孔连接起来,从而使介质瞬时进入到钢表面,同时有一部分二价铁离子从铁素体颗粒中扩散进入液相,生成多孔的、附着性较差的Fe3O4颗粒,沉积在较致密的Fe3O4内伸层上,形成传热性较差的外延层,该膜在高温纯水中具有一定的溶解性。OT工况时,由于不断向金属表面均匀供氧,金属表面仍保持一层Fe3O4内伸层,而由Fe3O4微孔通道中扩散出来进入水相的二价铁离子被氧化,生成Fe2O3的水合物,沉积在外延生成Fe2O3保护层,从而使金属表面形成致密的"双层保护薄"。