CSC-280系列产品调试手册new
- 格式:pdf
- 大小:2.53 MB
- 文档页数:81
操作序列操作序列1 紧急情况释放开关S3(急停)左旋转2 旋转钥匙开关S1(电源总输入)选‘I’改变选‘PGC’显示消耗-电源电压控制变压器-选PGC显示数据参数,仅在连接气体自动控制时有效3绿色灯S2开(准备好操作)打开开关等离子电源、风扇、冷却控制打开测试:-显示电弧电压(20)和切割电流(19)在不久后-20电弧电压的实际值-19目前设定值预留-绿色开S2准备好操作-(16)黄色LED OFF‘累计错误’- (7)绿色LED ON‘冷却系统正常’- (8)绿色LED ON‘其他供应正常’- (9)绿色LED ON‘电源温度正常’此单元已经准备就绪4 旋转开关S5(切割技术范围)按照制定计划选择的切割参数5 操作PGC3,PGE360 orPGE3-360(见维修手册)预选等离子单元(解除不合格单元),激活等离子易损件、气体等切割参数电位计-电压显示(20)错误错误 原因原因//解决方案解决方案1当S1开关打开总电源,激活S2绿色开关后风扇和冷却液单元无法启动 -S3急停开关未复位-通信线路X102(C3-C4)(系统发出紧急停止)没有堵塞-电源后盖板以及PBA 开-等离子割炬控制电缆未连接上X121 -电机断路器F7冷却装置关闭2风扇和冷却单元ON,(16)黄色LED‘累计错误’ON 和(8)绿色LED‘气体供应’OFF选择气体压力过低 (见切割参数表) 3(16)黄色LED‘累计错误’ON,(7)绿色LED‘冷却回路’OFF,报警信号显示在电位器上(19) -冷却装置水泵旋转方向相反→调换俩相线 -冷却液流量过低 -缺少冷却液 -主开关S1冷却装置关-电机断路器F7冷却装置关闭4(16)黄色LED‘累计错误’ON,(9)绿色LED‘电源温度’OFF -整流器过热→风扇运行冷却、根据维护手册清洗本单元和箱体风扇后过滤垫 5(11)白色LED ‘主弧’OFF:主电源OFF,电流显示器(19)当等离子电源关闭10秒以后 -测试弧时间>10S -工件电流无回路-工件连接电缆无连接-穿孔高度不正确-测试弧与工件未接触该HiFocus 280i 等离子电源显示顺等离子电源显示顺序为错误代码序为错误代码序为错误代码,,如果在运行中或者操作过程中中或者操作过程中,,电流电流显示记显示记显示记显示数字从显示数字从和各自LED等亮等亮,,这些错误的描述见下表这些错误的描述见下表显示信息(19)表示信息 原因1 气体错误 手动气体控制台:(PGE) -气体压力过低-控制气体4 测试弧错误起弧时间>10S工件无电流通过-工件电缆未连接 -初始定位高度不正确 -主弧与工件无接触5 起弧错误 2秒内未起弧6 主弧丢失 主弧未与工件连接7 距离错误 割炬在切割过程中距离过小8 气体测试错误 测试时间大于三分钟9 引导弧丢失 在起弧过程中引导弧未建立,无主弧10 通讯错误 仅在自动气体控制有效11 数据库错误 仅在自动气体控制有效202122252627电源出错 联系服务人员303132 354041424344505152 55。
螺杆空压机微电脑控制器MAM-KY12S(B)-(Ⅻ)型(中文液晶显示-280)用户手册深圳市普乐特电子有限公司地址:深圳市福田区商报路天健工业区25栋西六楼电话:(0755)83172098 83172068 邮编:518034传真:(0755)83172966 E-mail:plt@网址:特点:●LCD中英文显示●对电机具有短路、堵转、缺相、过载、不平衡等全方位保护功能●对电机具有起停控制、运行控制●对空压机进行防逆转保护●对多点温度进行检测与控制保护●自动调节负荷率控制压力平衡●高度集成,高可靠性,高性价比●远程/机旁选择控制●联动/独立选择运行●RS-485通讯功能一、基本操作1、按键说明图1︱——起动键:按此键可起动电机运行○——停机键:按此键可停止电机运行S——设定键:修改完数据后,按此键确认数据存储输入▲——上移键:数据修改时,按此键上翻修改该数位;在菜单选择时作为选择键。
▼——下移键:数据修改时,按此键下翻修改该数位;在菜单选择时作为选择键。
◆——移位键/确认键:修改数据时,此键作为移位键;在菜单选择时作为确定键。
C——返回键/复位键:在菜单操作时作为返回键返回上一级菜单;故障停机时,按此键复位。
2、状态显示与操作机组通电后显示如下界面:5秒后显示以下主界面:按“▼”进入以下菜单选择界面:a、运行参数查看按“▲”或“▼”移动黑色滚动条到“运行参数”菜单后,按确认键“◆”后弹出下一级菜单:再按“◆”弹出如为最后一级菜单,界面不会出现黑色滚动条,按返回键“C”返回上级菜单或主界面。
如在某一界面停止操作,数秒钟后自动返回主界面。
用“▲”、“▼”移动键、确认键“S”和返回键“C”根据上述方法可完全观察到运行时间、本次运行时间、维护参数、历史故障、出厂日期、现场故障等运行参数并返回到上级菜单。
b、用户参数1)、参数修改方法══在运行状态和停机延时过程中不能修改用户参数和厂家参数══用前述运行参数查看的方法可查看和修改用户参数,如修改压力上限,操作方法如下:按“▲”或“▼”移动黑色滚动条到“用户参数”项后按确定键“◆”弹出再按确定键“◆”弹出如不继续按确定键“◆”即可查看用户参数。
SCD-280八单元同步调节器1.产品概要SCD280为江阴市环希工业控制设备有限公司成熟产品。
本产品经过多年的工业现场考验和设计、工艺的不断完善,功能实用,抗干扰能力强,稳定可靠。
本产品的主要特点如下:☆内含八路独立可编程模拟单元,一路内部主给定,八路外部反馈输入,内带±5V反馈电源。
☆内部主给定可采用上升、下降端子外接按钮进行调节。
2.产品外观及端子分配端子说明:开关量信号输入端子:2(启停);4(故障输入);13(下降);6(上升)开关量信号输出端子:运行信号:53(常闭);54(常开);55(公共端)报警信号:50(常闭);51(常开);52(公共端)模拟量主给定端子:9(信号);10(信号)反馈量端子:29(1#反馈)27(2#反馈)25(3#反馈)23(4#反馈)21(5#反馈)19(6#反馈)17(7#反馈)15(8#反馈)输出量端子:30(1#输出)32(2#输出)34(3#输出)36(4#输出)38(5#输出)40(6#输出)42(7#输出)44(8#输出)P6-1江阴市环希工业控制设备有限公司1.GS2.R/S3.+24V4.Err5.GS6.UP7.+10V8.GND9.G110.G211.GND 12.+10V 13.DOWN 14.GND 15.GF816.GND 17.GF718.GND 19.GF620.GND 21.GF522.GND 23.GF424.GND 25.GF326.GND 27.GF228.GND 29.GF1+24V地启停端子+24V电源≤80mA 外部故障输入+24V地上升端子+10V参考电压信号地外部主给定一外部主给定二信号地+10V参考电压下降端子信号地反馈输入8信号地反馈输入7信号地反馈输入6信号地反馈输入5信号地反馈输入4信号地反馈输入3信号地反馈输入2信号地反馈输入130.V131.GND 32.V233.GND 34.V335.GND 36.V437.GND 38.V539.GND 40.V641.GND 42.V743.GND 44.V845.GND 46.+5V 47.GND 48.-5V 49./50.TB251.TC252.TA253.TB154.TC155.TA156.GND 57.L 58.N单元1输出信号地单元2输出信号地单元3输出信号地单元4输出信号地单元5输出信号地单元6输出信号地单元7输出信号地单元8输出信号地反馈用+5V电源≤50mA 信号地反馈用-5V电源≤50mA 空脚报警信号常闭端报警信号常开端报警信号公共端运行信号常闭端运行信号常开端运行信号公共端开关电源接地端电源输入 220VAC 电源输入±20%50Hz参考电压端子:7,12(+10V)负载能力10mA46,48(±5V)负载能力200mA3(+24V)负载能力0.7A地端子:信号地:8,11,14,16,18,20,22,24,26,28,31,33,35,39,39,41,43,45,47。
CSC系统调试说明书PFISTER GmbH1.1.2 键的功能 (VT100)移动光标或选择参数输入数据时设置光标的位置回车键,用于输入或激活选择或接收数据输入数字或直接选择菜单输入十六进制的数 显示主菜单 刷新当前菜单,并切换到VT100 方式 刷新当前菜单,并切换到PHT 方式 错误确认 功能或指令中止 功能或指令执行 调用“服务联机”菜单(仅限于 CSC MASTER )1.1.3 PHT (PFISTER 手操器)的联机1.) 把PHT 联到CSC 的服务接口X17 插头上。
2.) 设备的标识符和版本号在PHT 的 1--3 行显示。
在第四行将显示“Ctrl Y > Connect”,这时PHT 已经准备就绪。
3.) 按“Ctrl Y ”键,PHT 与CSC 的联接就建立了。
4.) 按“Ctrl A” 键,显示主菜单。
下面数据将显示在PHT 上。
第一行 ->菜单字头第二行 ->参数说明第三行 ->技术值或参数设定第四行 ->错误信息(如果存在)如果有问题,检查与CSC 的联接和设置(波特率,数据格式)1.1.4 手操器 PHT 的按键功能描述F1 的题字和功能 传送PHT 的标识符 F2的题字和功能 执行 F3的题字和功能错误确认F4的题字和功能转到主菜单F5的题字和功能放弃 F6的题字和功能 提出用于输入字母和特殊字符的表格或在通电后进行组态滚动选择菜单或在选择参数时选择菜单 回车键,用于输入,接收或激活选择 设置光标的位置(输入的位置) 输入十进制数据或直接选择菜单1.2 操作及其显示的注解用 Ctrl + A 键可以从任何菜单返回主菜单。
回到上一级菜单用“0”键或把光标定位在<<Exit(0) 并按回车键。
任何输入和选择都用回车键来取舍。
每个选项会在左侧用“<….”来标记。
用键来选择。
任何一个输入和选择都可用“Ctrl + C ” 放弃,原设置保持不变。
Tuning Fork Level SwitchContents1.Models (4)2.Wiring (5)3.Fork Sensing Spot (6)4.Magnetic Test (6)5.Output Status (7)6.Installation (8)7.Simple Troubleshooting (9)1. Models2. WiringPower supply is DC. Output is PNP / NPN. Please see Figure 1.DIN & Cable Wiring:PNP Output:●High(Max.) Mode: No. 1 pin(Brown) is connected to N-. No.3pin(Blue) is connected to L+. Output is connected to No. 2pin(Black), then connected to N-. No. 4 pin(Yellow Green) goes toground.●Low(Min.)Mode: number 1 pin(Brown) is connected to N-.No.2 pin(Black) is connected to L+.●Output is connected to No. 3 pin(Blue), then connected to N-.No.4 pin(Yellow Green) goes to ground.NPN Output:●High(Max.) Mode: No. 1 pin(Brown) is connected to L+. No.3pin(Blue) is connected to N-. Output is connected to No. 2pin(Black), then connected to L+. No. 4 pin(Yellow Green) goes toground.●Low(Min.)Mode: No. 1 pin(Brown) is connected to N-. No.3 pin(Blue) is connected to L+. Output is connected to No.2 pin(Black), then connected to L+. No. 4 pin(Yellow Green) goes toground.3. Fork Sensing SpotTF280-N/TF280-P fork sensing spot is shown as Figure 3 below. Considering testing medium is water (S.G.=1 g/cm3) , sensing spot is at the fillister about23mm from the tip. If testing medium has S.G. lower than 1g/cm3, sensing spot would be above the fillister. In contrast, sensing spot will be below the fillister.4. Magnetic TestAfter the switch is installed and powered, magnetic test function can beperformed accordingly. The testing point is marked on the housing label. User holds the magnet and moves it close to testing point, the output status will switch from NO. to NC. or NC to NO. and red LED would switch ON or OFF while fork continues to vibrate. When magnet is pulled away from the testing point, theoutput status and red LED would return as default while fork continues to vibrate.The purpose of testing is to confirm the wiring and functioning are correct.5. Output StatusTF280-N/TF280-P is equipped with 12~55 Vdc, top of housing would light up with green LED.DIN & Cable type:●Low(Min.) Mode: Tuning fork switch will be actuated 3 seconds after thepower is on. Relay is NO and red LED indication is on. When tuning forkis covered by testing medium, vibration stops and relay becomes NC.Red LED indication is off.●High(Max.) Mode: Tuning fork switch will be actuated 3 seconds after thepower is on. Relay is NC and red LED indication is on. When tuning forkis covered by testing medium, vibration stops and relay becomes NORed LED indication is off.●Flashing red indicates abnormal: Possible causes overloads or shortcircuitload back, equipment malfunction or wear tuning fork probe.6. InstallationHorizontal Installation:1. Can be applied in viscosity, powder and, liquid. Do not inst.(Figure 1)2. When installing the product, The position hole plug must be upwarddirection.If not, incorrect installation could be damage the product.(Figure 2)(Figure 1) (Figure 2)Vertical Installation:1. Opening of the two fork blades is to be as the flow direction. (Figure 3)2. Do not install near substance inlet. (Figure 4)(Figure 3)(Figure 4)7. Simple Troubleshooting11 M5733/0119。
Haawking DSC2803X数字信号控制器数据手册编号:北京中科昊芯科技有限公司2022年03月V1.3历史版本记录目录1.器件概述 (5)1.1产品特性 (5)1.2应用 (6)2.DSC28034简介 (7)2.1器件特性 (7)2.2产品编码 (8)2.3引脚分配 (9)2.4信号说明 (10)3.功能概述 (19)3.1系统架构 (19)3.2内存映射 (19)3.3简要说明 (21)3.3.1HXS320F2803x DSC (21)3.3.2内存总线 (21)3.3.3外设总线 (21)3.3.4实时JTAG和分析 (22)3.3.5闪存 (22)3.3.6M0、M1、L0、L1SARAM (22)3.3.7引导ROM (23)3.3.8.1JTAG引导模式 (23)3.3.8.2GetMode获取模式 (24)3.3.8.3引导加载器使用的外设引脚 (24)3.3.8安全性 (24)3.3.9外设中断扩展(PIE)模块 (25)3.3.10外部中断(XINT1-XINT3) (26)3.3.11内部振荡器、外部振荡器和PLL (26)3.3.12看门狗 (26)3.3.13外设时钟 (26)3.3.14低功耗模式 (27)3.3.15通用输入/输出(GPIO)复用器 (27)3.3.1632位CPU定时器(0,1,2) (28)3.3.18控制外设 (28)3.3.19串行端口外设 (29)3.4寄存器映射 (29)3.5器件仿真寄存器 (30)3.7LDO/VREG/BOR/POR (34)3.7.1VREG (34)3.7.1.1使用片上VREG (35)3.7.1.2不使用片上VREG (35)3.7.2片上上电复位(POR)和掉电复位(BOR)电路 (35)3.8系统控制 (36)3.8.1内部零引脚振荡器 (39)3.8.2晶体振荡器选项 (40)3.8.3基于PLL的时钟模块 (41)3.9低功耗模块 (41)4.外设 (43)4.1模拟器件 (43)4.1.1特性 (43)4.1.2ADC MUX多路复选 (47)4.1.3比较器模块 (47)4.2同步串行通信接口(SPI)模块 (48)4.3异步串行通信接口(SCI)模块 (51)4.4本地互联网络(Lin)模块 (53)4.5增强型控制器局域网络(eCAN)模块 (55)4.6内部集成电路接口(I2C)模块 (58)4.7增强型PWM模块(ePWM1/2/3/4/5/6/7) (61)4.8高分辨率PWM模块(HRPWM) (63)4.9增强型脉冲捕获模块(eCAP) (64)4.10高分辨率脉冲捕获模块(HRCAP) (66)4.11增强型正交编码器模块(eQEP) (67)4.12JTAG端口 (72)4.13GPIO控制寄存器 (74)4.14直接存储访问存储单元(DMA) (78)5.开发支持 (83)5.1集成开发环境Haawking IDE (83)5.2仿真器 (84)5.2.1简介 (84)5.2.2概览 (84)5.2.2.1特性 (85)5.3串口下载器 (86)5.4JTag下载工具 (87)6.1绝对最大额定值 (88)6.2推荐工作条件 (88)6.3ESD额定值 (89)6.4电气特性 (89)6.5功耗 (91)6.6散热设计考虑 (92)7.热特性/机械数据 (93)7.1LQFP80 (93)7.2TQFP64 (94)8.参考文献 (95)1.器件概述1.1产品特性高能效32位处理器(H28x内核)✓主频120MHz(周期8.33ns)✓哈佛(Harvard)总线架构✓硬件乘法/除法单元✓4/6通道高速DMA✓快速中断响应和处理✓统一存储器编程模型✓高效代码(使用C/C++和汇编语言)增强型控制外设✓增强型脉宽调制器(ePWM)✓高分辨率PWM(HRPWM)✓增强型捕获(eCAP)✓高分辨率输入捕获(HRCAP)✓增强型正交编码器脉冲(eQEP)✓模数转换器(ADC)✓片载温度传感器✓比较器芯片及系统开销✓3.3V单电源供电✓无上电顺序要求✓集成上电和掉电复位✓代码安全模块✓无模拟支持引脚时钟和系统控制✓两个内部12MHz零引脚振荡器✓片载振荡器/外部时钟输入✓看门狗定时器模组功能✓支持锁相环路(PLL)倍频系数动态调整多达45个具有输入滤波功能、可单独编程的多路复用GPIO✓可支持所有外设中断的外设中断扩展(PIE)模块✓三个32位CPU定时器✓每个ePWM模块中包含独立的32位定时器✓片载存储器✓闪存,SRAM,OTP,引导ROM可用128位安全密钥/锁✓保护安全内存块✓防止固件逆向工程✓串行端口外设✓一个SCI(UART)模块✓两个SPI模块✓一个内部集成电路(I2C)总线✓一个本地互连网络(LIN)总线✓一个增强型控制器局域网络(eCAN)总线高级仿真特性✓分析和断点功能✓封装选项✓80引脚薄型四方扁平(LQFP)封装✓64引脚TQFP封装✓温度选项✓工作温度:-40°至105°1.2应用●电器●医疗、保健与健身●楼宇自动化●电机驱动器●电动汽车、混合动力电动汽车(EV/HEV)动力传动●电力传送●工厂自动化●电信基础设施●电网基础设施●2.DSC28034简介2.1器件特性表2-1DSC2803x产品特性(1):ADC主频=30MHz时,转换速率是1.56Msps,由于可以同时采样转换两个通道,故最高速率为3.12Msps。