产品说明(阿米迪)
- 格式:pptx
- 大小:1.43 MB
- 文档页数:27
B-18Series 260HHeavy Duty Threaded Well for 1⁄4" Diameter ElementsApplication:Standard length, 1⁄4" bimetal thermometers. #20-gage thermocouple elements. Unarmoredliquid-in-glass test thermometers. Other temperature-sensing elements having 0.252" maximum diameter.Connection Size:3⁄4" NPT and 1" NPT are standard. Other thread sizes are available upon request.Protective Coatings for Thermowells:•Resist Corrosion •For Chemical Baths •Color-Coded Sensors for Process Control•Available in PFA, Epoxy and other materialsConsult Sales Department for complete information Materials:Brass (ASTM B-16), Carbon Steel (C-1018), Stainless Steel A.I.S.I. 304 & A.I.S.I. 316, Monel. Wells are also available in special materials; prices on request.Cap and Chain Options:For Brass cap, add $4to price and add suffix “-CC (Brass)”to the end of the model number on your order. For 304 SS cap, add $7to the price and add suffix “-CC (304SS)” to the end of the model number.Discount Schedule25-100.......................20%101 and up....Consult SalesShown close to actualCANADA www.omega.ca Laval(Quebec) 1-800-TC-OMEGA UNITED KINGDOM www. Manchester, England0800-488-488GERMANY www.omega.deDeckenpfronn, Germany************FRANCE www.omega.frGuyancourt, France088-466-342BENELUX www.omega.nl Amstelveen, NL 0800-099-33-44UNITED STATES 1-800-TC-OMEGA Stamford, CT.CZECH REPUBLIC www.omegaeng.cz Karviná, Czech Republic596-311-899TemperatureCalibrators, Connectors, General Test and MeasurementInstruments, Glass Bulb Thermometers, Handheld Instruments for Temperature Measurement, Ice Point References,Indicating Labels, Crayons, Cements and Lacquers, Infrared Temperature Measurement Instruments, Recorders Relative Humidity Measurement Instruments, RTD Probes, Elements and Assemblies, Temperature & Process Meters, Timers and Counters, Temperature and Process Controllers and Power Switching Devices, Thermistor Elements, Probes andAssemblies,Thermocouples Thermowells and Head and Well Assemblies, Transmitters, WirePressure, Strain and ForceDisplacement Transducers, Dynamic Measurement Force Sensors, Instrumentation for Pressure and Strain Measurements, Load Cells, Pressure Gauges, PressureReference Section, Pressure Switches, Pressure Transducers, Proximity Transducers, Regulators,Strain Gages, Torque Transducers, ValvespH and ConductivityConductivity Instrumentation, Dissolved OxygenInstrumentation, Environmental Instrumentation, pH Electrodes and Instruments, Water and Soil Analysis InstrumentationHeatersBand Heaters, Cartridge Heaters, Circulation Heaters, Comfort Heaters, Controllers, Meters and SwitchingDevices, Flexible Heaters, General Test and Measurement Instruments, Heater Hook-up Wire, Heating Cable Systems, Immersion Heaters, Process Air and Duct, Heaters, Radiant Heaters, Strip Heaters, Tubular HeatersFlow and LevelAir Velocity Indicators, Doppler Flowmeters, LevelMeasurement, Magnetic Flowmeters, Mass Flowmeters,Pitot Tubes, Pumps, Rotameters, Turbine and Paddle Wheel Flowmeters, Ultrasonic Flowmeters, Valves, Variable Area Flowmeters, Vortex Shedding FlowmetersData AcquisitionAuto-Dialers and Alarm Monitoring Systems, Communication Products and Converters, Data Acquisition and Analysis Software, Data LoggersPlug-in Cards, Signal Conditioners, USB, RS232, RS485 and Parallel Port Data Acquisition Systems, Wireless Transmitters and Receivers。
阿米迪说明【商品名】阿米迪【通用名】妥洛特罗贴剂【汉语拼音】TuoLuoTeLuoTieJi【英文名】Tulobuterol Patches【主要成分】妥洛特罗【化学名】(+/-)-2-氯-2-[(叔丁基氨基)甲基]苯甲醇盐酸盐【分子式】C12H19Cl2NO【分子量】264.19【性状】本品为白色方形带圆角的粘性贴片,粘性层上覆有白色衬垫。
【适应症】用于缓解支气管哮喘、急性支气管炎、慢性支气管炎、肺气肿等气道阻塞性疾病所致的呼吸困难等症状。
【用量用法】通常1日1次,以妥洛特罗计算成人为2mg,儿童0.5~3岁以下为0.5mg,3~9岁以下为1mg,9岁以上为2mg,粘贴于胸部、背部及上臂部均可。
【药理毒理】作用于支气管平滑肌的β2-受体,激活与β2-受体有紧密关系的腺苷酸环化酶(adenyl cyclase)。
由此细胞内腺苷三磷酸(ATP)改变为环腺苷酸(cyclic AMP),显示出支气管扩张的作用以及气管纤毛运动促进作用及镇咳作用。
【药代动力学】【不良反应】获批准时,1,002例安全性评价对象中,发现不良反应116例(11.58%)、152件次,其主要为震颤23件(2.30%),心悸17件(1.70%),粘贴部位搔痒感34件(3.39%)、发红25件(2.50%)、皮疹25件(2.50%)等。
另外,发现临床检查值有异常变动的是CK(CPK)升高28件(7.20%),但未见伴有临床症状。
偶有可能发生严重不良反应,包括过敏反应和严重血清钾值下降。
【注意事项】1、慎重用药(以下患者需慎重使用):甲状腺机能亢进的患者(有症状恶化的危险);高血压患者(有可能使血压升高);有心脏疾病的患者(有可能出现心悸、心律不齐等);糖尿病患者(有糖代谢亢进、血糖升高的危险);特应性皮炎患者(粘贴部位易出现搔痒感、发红等症状);老年患者(参照“老年患者用药”)。
2、重要注意事项:由于本品不是治疗支气管哮喘的基本病理-气道炎症的药物,因此需视患者的症状,适当并用类固醇制剂、茶碱制剂等处置;按用法和用量正确使用未见效时(标准为1~2周),认为不适用本品,请停止使用。
Seat Belts (cont'd)Fasten Seat Belt Warning Light and Warning BeeperLap Belt Warning Indicator:Both the light and thewarning beeper will go on for aboutsix seconds if the ignition switch isturned on when the driver's lap beltis not fastened. The beeper will notgo on if the driver's lap belt isfastened, but the warning light willcome on for about six seconds eachtime, to remind the driver to havepassengers put their belts on.Automatic Shoulder Belt Warning Indicator:The warning light will come on if either of the automatic shoulder belts is unlatched with the ignition ON. The beeper will sound for approximately six seconds while the warning light is ON. Relatch the belt: the light should go off when the belt is latched.The warning light will also come on while the shoulder belt buckle moves from its front off position to its rear locked position.Automatic Shoulder Belt Malfunction Indicator:The warning light will flash and the beeper will sound rapidly if either shoulder belt buckle stops before completing its full cycle (see page 126 for manual operation).NOTE:If the shoulder belt's tensioner mechanism locks and prevents the buckle from moving fully forward when you want to get out, recycle the system by closing the door and reopening it.The buckle should move fully forward; if it does not, recline the seat-back and use Emergency Belt Release (see page 11).When the system does not function by either method, have the system checked by an authorized Honda dealer.If the light and beeper do not function at all or if they come on even with the belts latched and doors fully closed, it indicates a malfunction in the seat belt system. In the event of a collision, severe personal injury could result. The system should be checkedimmediately by an authorized Honda dealer.Child RestraintChildren riding in the car should be restrained to minimize the risk of injury in an accident, sudden stop or sudden maneuver.According to accident statistics provided to the National Highway Traffic Safety Administration (NHTSA), children are safer when properly restrained in the rear seating positions than in the front seat.For smaller children, we strongly recommend the use of a commercially available child restraint system that meets the Federal Motor Vehicle Safety Standard (FMVSS) because it offers the most protection against injury. All states now have laws which require that small children must be seated in a child passenger seat restraint system. Check local laws.Before buying a particular child restraint system, make sure it fits your car seat and seat belts, and fits your child. Follow the child seat manufacturer's instructions when installing the seat.Children who have outgrown the child restraint system should use one of the seat belts.Make sure the belt is snug against the child's body with theshoulder portion going over the shoulder and across the body to evenly distribute the belt's restraining force.Check that the lap portion of the belt is positioned low on thechild's hipbone and below the abdomen.This way if the car is involved in an accident, the child will be less likely to slide under the seat belts.If the belt is too close to the child's neck or throat, you may wantto consider putting the child in an automobile booster seat that meets the Federal Motor Vehicle Safety Standard (FMVSS).Children should never ride unrestrained in an automobile.Never use an infant carrier or child safety seat that "hooks" over a seat-back; it may not provide adequate security in an accident.Never allow a child to be held in a person's arms while they arein a moving vehicle. Holding a child in a moving vehicle does not provide the child with any means of protection during an accident, even if the person holding the child is wearing a seat belt.(cont'd)Seat Belts (cont'd)Installation of Child SeatAll child restraint systems are designed to be secured by lap belts or the lap belt portion of a lap-shoulder belt. The automatic shoulder belt system at the front passenger seat should not be used to secure the child restraint system. If a child seat must be installed on the front seat, place the shoulder portion of the belt behind the child seat and secure the child seat with the lap belt only.Children could be endangered in a crash, if their child restraints are not properly secured. Follow the child seat manufacturer's instructions when installing the seat.Your Honda automobile is equipped with attachment points specifically for a rear seat mounted child restraint system which uses a top tether.The tether attachment points are located on the rear tray, just behind the rear seat-back.When the child restraint system is not in use, remove it from the car or secure it with the seat belt to keep it from becoming a projectile in the event of an accident.NOTE:See your Honda dealer for installation of the child restraint system.Pregnant WomenA pregnant woman should use the shoulder and lap belts to help lessen the chance of injury and/or the amount of injury in an accident.It is desirable that a pregnant woman ask her doctor at each medical check-up if she can drive, and also ask about the most appropriate way of wearing the lap/shoulder belt.If a rear seat lap belt is used, it should be worn as low and snugly as possible over the hips.InspectionAll parts of the seat belts, including the belt fabric, should be regularly inspected for fraying, loosening, wear and other damage. Keep the belts in good condition at all times to reduce the chance of being injured in an accident, and to minimize any injuries that do occur. Make sure the buckles, retractors, tongue plates, guides and anchors all work properly.Don't let anything get inside the buckle or the retractor; it could cause latch or retractor failure.CleaningThe belts should always be kept clean and dry; wet or damp belts can cause rewinding problems. To clean the belts, pull them all the way out of their retractors and use warm water and a mild soap; then let them air-dry fully extended, in the shade, with the car windows open.Never bleach, dye or clean the belts with chemical solvents; itwill weaken the fabric.Do not remove the seat belts from the car to wash them.ReplacementReplace the seat belt if:1 .The belting is cut, punctured, burned, etc.2. The buckle or retractor does not work properly.3. It was being worn at the time of a collision (also check for damage at the seat belt anchor points).4. Its condition is questionable.。
E-14Order Online Over 100,000 Products Available! ®To download information and to order Conductivity Instrument products online, visit CDB-387The CDB-387 is a microprocessor- based, benchtop conductivity, resistivity and TDS meter. The unit has a large LCD display and membrane keypad for easy operation. The meter features automatic temperature compensation, programmable temperature coefficient, recorder output and bi-directional RS232C output. The CDB-387 measures 5 conductivity ranges, 2 resistivity ranges and 4 TDS ranges. The CDB-387 will automatically select the most suitable range to provide maximum resolution.The CDB-387 operates off ac power or a 9V battery. The 9V battery serves as a back-up to retain calibration data, even in the event of a power failure, and allows for portable field measurements. The unit is supplied with a glass dip-style conductivity cell with an integral temperature sensor, K = 1.0, calibration solutions and 9V adaptor.SpecificationsConductivity Ranges: 0 to 20.00 µS/cm; 0 to 200.0 µS/cm; 0 to 2000 µS/cm; 0 to 20.0 mS/cm; 0 to 200 mS/cm TDS Ranges: 0 to 20.00 ppm; 0 to 200.0 ppm; 0 to 2000 ppm; 0 to 20 kppm Resistivity Ranges: 0 to 2.000 M Ω/cm, 0 to 20.00 M Ω/cm Accuracy: ±1% of reading Automatic Temperature Compensation: 0 to 50°C (32 to 122°F)Reference Temperature: 25°C (77°F) [selectable 20°C (68°F)]Temperature Coefficient: User Temperature Measurement Range: -30 to 130°C (-22 to 266°F)Resolution: 0.1°C Accuracy: ±0.3°C Recorder Output: 0 to 200 mV Digital Output: Bi-directional RS232C Power: 115 Vac with 9V adaptor or 9V battery (included) Display: 12.7 mm (0.5") LCD Dimensions: 210 L x 150 W x 88 mm H (8.3 x 5.9 x 3.5")Weight: 600 g (1.3 lb)Comes complete with meter, CDE-5001-GD1 glass dip probe, conductivity solution, power adaptor, 9V battery and operator’s manual.Note: Other cell configurations are available. Contact OMEGA’S pH and Conductivity Engineers.Ordering Example: CDB-387, benchtop conductivity/resistivity and TDS meter and CDE-5004-ED10, epoxy dip probe.Shown smaller than actual size.Benchtop Microprocessor-Based Conductivity/Resistivity/TDS Meters U M easures 5 Conductivity Ranges, 4 TDS Ranges and 2 Resistivity Ranges (Additional Probes May Be Required)U Autoranging for Maximum ResolutionU Analog and Digital Outputs StandardU Standard RS232 OutputIncludes CDE-5001-GD glass dip style conductivity probe with integral temperature sensor. Replacement available.。
NOTE: Perform installation when gas gauge reads below 1/4 tank. A lighter gas tank will be easier to manage. Also, have a partner handy to assist with the removal and installation of the tank.WARNING: When working near gasoline, always be cautious not to have any heat or ame generating device as this could result in combustion and cause injury or death. Always keep a re extinguisher handy when working with combustible uids.1. Disconnect battery terminals before beginning installation of this product. Disconnect negative terminal rst making sure not to contact the positive terminal with the tool being used.2. Remove the gas cap from the vehicle to relieve the pressure inside the tank. Cut zip ties holding axle vent tubes to the ller hose. To gain access to these tubes, remove the plastic cover from underneath the rear quarter panel.Remove the fuel ller assembly by rst removing the 4 screws holding the ller neck in position. Next, remove the 4 screws holding the plastic bezel.Save these screws, they will be used to reinstall ller neck. NOTE: Instead of removing the complete ller assembly, ller and over ow hoses can be removed directly from the tank by loosening the clamps securing them.3. Some TJ models will have a grounding strap attached to the driver’s side shock mount. Use a at head screwdriver to remove it. Disconnect the electrical connector on top of the gas tank by sliding the red clip to the side and unlocking the connector. Also disconnect the evaporation hose and high pressure line from the metal tubing at the left front corner of the tank. NOTE:Have a bucket and some shop rags handy. Fuel may spill out when disconnecting fuel lines.4. Position oor jack centered beneath the gas tank to hold it in place.Remove the 7 nuts holding the gas tank and the OE skid pan to the vehicle. Save these nuts as they will be used to reinstall the gas tank. Do not remove the nuts securing the gas tank to the OE skid pan straps untill the gas tank is on the ground.Contents: 1. TJ Gas Tank Skid Plate (1)97-06 TJ GAS TANK SKID PLATE5. Late model jeeps will have the fuel rail connected to the top of the tank. Using the oor jack, lower the gas tank approx 3 inches. Unhook the fuel rail from the top of the tank and disconnect the vent hose from the rollover valve at the back right corner of the tank.6. Once all lines and wires are disconnected from the gas tank, proceed to lower and completely remove the tank from the vehicle. Be sure to guide the ller assembly making sure it doesn't snag on anything. Place the gas tank on the ground. Fit RR skid plate to vehicle without gas tank in place to make sure slots align with the vehicles mounting fasteners.7. Remove the nuts holding the straps to the OE skid pan. Reinstall these straps in the RR skid plate using the square cutouts in the front of the pan.Remove gas tank from OE skid pan and place into the RR skid plate . Locate the proper slots in the rear of the RR skid plate for each straps threaded stud.Tighten the nuts onto the studs to secure the gas tank to the RR skid plate. Be careful not to over tighten these bolts.8. Position oor jack under vehicle with gas tank assembly centered on top. Slowly raise into position being sure to guide ller assembly to its appropriate location. The gas tank assembly may need to be tilted back to avoid the rear track bar when lifting. Stop about 3 inches away from the skid plates mounting position and reconnect the fuel rail to the top of the tank. It may be easier to reconnect the vent tube to the rollover valve and the electrical connector at this time also.97-06 TJ GAS TANK SKID PLATE9. Resume lifting the gas tank assembly slowly into position. Line up factory mounting studs with the slots in the skid plate. Tighten the 7 nuts onto the factory studs evenly to 17 ft-lbs to secure gas tank assembly into position. Reconnect the high pressure fuel line, evaporation hose, and electrical connector (if not already connected in step 8).97-06 TJ GAS TANK SKID PLATE10. Locate 2 axle vent hoses and zip tie hoses to fuel ller neck. Also,reconnect the grounding strap to the driver side shock mount ifapplicable. Hold ller neck in position and reinstall 8 screws to securethe ller assembly to the vehicle. Reconnect the fuel ller and over owhoses to the tank if they were detached prior to lowering the tank.11. Reconnect vehicle wires to the battery terminals. Attach negative terminal wires last. Once all wires are connected and installation is complete, start engine. You may need to pump the gas pedal a few times to get fuel through the lines and to the engine. Once started, check all fuel lines for leaks.Rugged Ridge Limited WarrantyApplies to Rugged Ridge Products by OMIX-ADA Inc.Please find warranty card supplied with product for more information. Warranty cardshould be filled out and returned to address listed below.OMIX-ADA Inc.460 Horizon Dr. Suite 400Suwanee, Georgia 30024Page 2 of 3。
Intrinsically Safe DTAM Plus,Series B (Catalog Number 2707-L40P4)This Release Note supports the Introduction of Series B of the Intrinsically Safe (IS) DTAM Plus, which includes CE certification.The DTAM Plus family of products provide a low cost, general purpose operator interface to Allen-Bradley PLC R or SLC t processors. The IS DTAM Plus operates in hazardous environments (Class 1 Division 1) where an explosive atmosphere may exist, and meets requirements for Groups C and D. This document provides information you will need to install and operate the IS DTAM Plus.•Product Information •Accessories •Warnings and Cautions •Isolation Barriers •Intended Audience •Wiring Connections •Feature Summary Refer to the following DTAM Plus literature for product information.•DTAM Plus Product Data Sheet (Publication 2707-2.0)•DTAM Plus User Manual (Publication 2707-800)•DTAM Programming Software Programming Manual (Publication 2707-801)The information provided in these publications applies to the IS DTAM Plus with the exceptions noted in this publication.Note the following before attempting to install or operate the Intrinsically Safe DTAM Plus.!DANGER: Substitution of components may impair intrinsic safety.DANGER: La substitution de composants peut compromettre la securite intrinseque.!ATTENTION: The Intrinsically Safe DTAM Plus is only certified for hazardous locations when the communications and input power lines are properly connected to certified isolation barriers (energy-limiting devices).This document assumes that the user is familiar with installingequipment in hazardous locations and the use of isolation barriers.Document Update OverviewProduct InformationWarnings and CautionsIntended AudienceIntrinsically Safe DTAM Plus, Series B 2Publication 2707-800.6The following chart provides a summary of the differences between the IS DTAM Plus and other DTAM Plus products.To install and configure the IS DTAM Plus, you may need the following accessories.Software Upgrade KitVersion 6.0 of the DTAM Programming Software (DPS, Catalog No. 2707-NP Series F) is required to configure the IS DTAM Plus. If you are using an earlier version, update your software using the Upgrade Kit (Catalog No. 2707-NFK). An instruction sheet is provided with the kit.Isolation BarriersIsolation barriers isolate the safe side of an application from the hazardous side. Both the communication lines and power lines require isolation barriers. Isolation barriers are only required if the IS DTAM Plus is installed in a hazardous environment or is communicating with a controller in a hazardous location.Feature SummaryDTAM IS AccessoriesIntrinsically Safe DTAM Plus, Series B 3Publication 2707-800.6Isolation barriers are required when the IS DTAM Plus or a connected device is located in a hazardous location. Isolation barriers isolate the safe side of an application from the hazardous side. Both the power input and communication lines must be isolated.Input Power Line Barriers The following are recommended barrier suppliers and part numbers.•Type ZH-112/Ex Line Barrier Supplier: Pepperl + Fuchs •Type WE77-112/Ex Line Barrier Supplier: Pepperl + Fuchs !ATTENTION: Refer to the instructions provided with the isolation barrier for installation instructions.!ATTENTION: Never connect or disconnect equipment while the circuit is live unless the area is known to be non-hazardous. Failure to observe this precaution could result in injury or death.The following figures show how to wire these isolation barriers:11-13V DC11-13V DCZH-112/ExInput Line Barrier WE77-112/Ex Input Line Barrier Isolation BarriersIntrinsically Safe DTAM Plus, Series B 4Publication 2707-800.6Communication Line Barriers•RS-232 Communication Line BarrierSupplier: Pepperl + FuchsPart Numbers:KHD2-EF-EX 2.P-RS232 (1 required)Z-966 (1 required)•RS-485 Communication Line BarrierSupplier: Pepperl + FuchsPart Numbers:Z-966 (3 required)!ATTENTION: Refer to the instructions providedwith the isolation barrier for installation instructions.!ATTENTION: Never connect or disconnectequipment while the circuit is live unless the area isknown to be non-hazardous. Failure to observe thisprecaution could result in injury or death.The following figures show how to wire these isolation barriers. The IS DTAM Plus Comm Port is a 9-pin D shell female connector. The cable that connects to the Comm Port requires a 9-pin D shell male connector.Pin 2 (RX232)Pin 3 (TX232)Pin 5 or 8 (Com)TxRxKHD2-FF-EX2.P (RS-232)Communication Line BarrierComm PortIntrinsically Safe DTAM Plus, Series B 5Publication 2707-800.6Pin 3 (TX232)Pin 5 or Pin 2 (RX232)Signal GroundRx Z966Communication Line Barrier (Shown for RS-232 Connections)Z966Communication Line Barriers (Shown for RS-485 Connections)Pin 1 (TX485–)Pin 2 (TX485+)Signal GroundTX485 –Pin 3 (RX485–)Pin 4 (RX485+)Signal Ground RX485 –Pin 5 or Pin 6 (TX Enable)Signal GroundComm PortPin 8 (Com)Comm PortPin 8 (Com)Intrinsically Safe DTAM Plus, Series B 6Publication 2707-800.6Upload/Download Cable BarriersThe upload/download cable between the IS DTAM Plus and your personal computer must also be isolated using isolation barriers, if used in a hazardous environment. The following diagram shows the cable connections for both 9 and 25 pin connectors.!ATTENTION: Refer to the instructions providedwith the isolation barrier for installation instructions. !ATTENTION: Never connect or disconnectequipment while the circuit is live unless the area isknown to be non-hazardous. Failure to observe thisprecaution could result in injury or death.Data InData OutSignal GroundData OutData InSignal GroundIntrinsically Safe DTAM Plus, Series B 7Publication 2707-800.6The IS DTAM Plus communicates with SLC or PLC controllersthrough its RS-485/RS-232 Communication Port. Refer to theDTAM Plus User Manual (Publication No. 2707-800) for cable and connector information. Isolation barriers for communication and power lines are required for all Class 1 Division 1 environments.IS DTAM Plus to an SLC with Isolation BarriersIn this application, the IS DTAM Plus and SLC controller areinstalled in two separate locations. Isolation barriers are required.IS DTAM Plus to an PLC with Isolation BarriersIn this application, the IS DTAM Plus and SLC controller areinstalled in two separate locations. Isolation barriers are required.Wiring ConnectionsIntrinsically Safe DTAM Plus, Series B8Publication 2707-800.6DisplayDimensions (Approximate)4 line x 20 characters Liquid Crystal Display with Yellow-Green Backlight Character Size: .19 x .12 inch (4.75 x 2.95 mm)Viewing Angle Horizontal ± 30 degrees Vertical –20 to +30 degreesHeight: 7.6 inch (193.0 mm)Width: 5.5 inch (139.7 mm)Depth: 2.5 inch (63.5 mm)Front Panel Size Height: 8.5 inch (215.9 mm)Width: 6.5 inch (165.1 mm)Weight 3.0 lbs (1.36 kg)KeypadStainless Steel Domed Membrane Operation Force:12 oz ±3 oz Operation Life: 1 million cyclesElectrical P4 Power Supply 11 – 13 VDC 250 mA maximum 0.5 Amp Fuse CommunicationsCommunication Port: RS-485 DH485 or RS-232 DF1Environmental Operating Temperature: 0 to 55 ° C (32 to 131 ° F)Storage Temperature: –20 to 70 ° C (–4 to 158 ° F)Humidity Rating: Up to 95% (Without Condensation)Class I Division 1 Groups C & D, hazardous locationsTemperature Code T3CEN50081-2 Class A (Industrial) EmissionsEN50082-2 Class A (Industrial) ImmunityFCC Part 15, Class AIf this product is installed within the European Union or EFTAregions, the following regulations apply.This apparatus is tested to meet Council Directive 89/336Electromagnetic Compatibility (EMC) Standards:•EN50081-2 Class A (Industrial) Emissions•EN50082-2 Class A (Industrial) ImmunityAccording to these Standards, the factor which determines, for EMC purposes, whether an apparatus is deemed to be “Industrial” or“Residential, commercial and light industrial”, is given in Clause 1of EN50081-2 as follows:Apparatus covered by this standard is not intended for connection to a public mains network but is intended to be connected to a power network supplied from a high- or medium-voltagetransformer dedicated for the supply of an installation feeding a manufacturing or similar plant.The product described in this Release Note is intended for use solely in an industrial environment as defined above. When installed in Europe, any other application is in contravention of European Union Directives, and a breach of those laws.SpecificationsAgency RatingsEuropean Union Directive ComplianceIntrinsically Safe DTAM Plus, Series B9Publication 2707-800.6Intrinsically Safe DTAM Plus, Series B 10Notes Publication 2707-800.6Intrinsically Safe DTAM Plus, Series B11 NotesPublication 2707-800.6Publication 2707-800.6 –March 1997Rockwell Automation helps its customers receive a superior return on their investment by bringingtogether leading brands in industrial automation, creating a broad spectrum of easy-to-integrateproducts. These are supported by local technical resources available worldwide, a global networkof system solutions providers, and the advanced technology resources of Rockwell.Worldwide representation.Argentina • Australia • Austria • Bahrain • Belgium • Bolivia • Brazil • Bulgaria • Canada • Chile • China, People’s Republic of • Colombia • Costa Rica • Croatia • Cyprus Czech Republic • Denmark • Dominican Republic • Ecuador • Egypt • El Salvador • Finland • France • Germany • Ghana • Greece • Guatemala • Honduras • Hong Kong Hungary • Iceland • India • Indonesia • Iran • Ireland •Israel • Italy • Jamaica • Japan • Jordan • Korea • Kuwait • Lebanon • Macau • Malaysia • Malta • Mexico •Morocco The Netherlands •New Zealand • Nigeria • Norway • Oman • Pakistan • Panama • Peru • Philippines • Poland • Portugal • Puerto Rico • Qatar • Romania • Russia • Saudi Arabia • Singapore • Slovakia • Slovenia • South Africa, Republic of • Spain • Sweden •Switzerland • Taiwan • Thailand • Trinidad • Tunisia • Turkey • United Arab Emirates United Kingdom • United States • Uruguay • VenezuelaRockwell Automation Headquarters, 1201 South Second Street, Milwaukee, WI 53204-2496 USA, Tel: (1) 414 382-2000 Fax: (1) 414 382-4444Rockwell Automation European Headquarters, Avenue Hermann Debroux, 46, 1160 Brussels, Belgium, Tel: (32) 2 663 06 00, Fax: (32) 2 663 06 40Rockwell Automation Asia Pacific Headquarters, 27/F Citicorp Centre, 18 Whitfield Road, Causeway Bay, Hong Kong, Tel: (852) 2887 4788, Fax: (852) 2508 1846World Wide Web: Publication 2707-800.6 –March 1997Supersedes Publication 2707-800.1 – December 199541061-037-01(A)Copyright 1997 Allen-Bradley Company, Inc. Printed in USA。
GGT SERIES—Gas-Fired/Hot WaterModule pressure and tempera-ture gauge (unmounted).Module pressure relief valve®A Caravan modular boiler system consists of two or more compact cast-iron boilers that offer significant advantages in terms of installed cost, efficiency and reliability. Caravan systems are based on step-firing just enough modules to meet heating demands. GGT systems are available from 600,000 to multi-million Btuh gross input. For additional information, see Caravan Engineering Manual, pub. C-30and Caravan gas application guide, pub. CG-10-HWG.*Specify gas by name, "Natural" or "Propane".†Net ratings are based on piping and pick-up allowance of 1.15. Slant/Fin should be consulted before selecting a boiler for installation having unusual piping and/or pick-up requirements. Ratings must be reduced by 4% at 2,000 ft. elevation and an additional 4% for every additional 1,000 ft. elevation over 2,000 ft.‡Net ratings in square feet based on emission rate of 150 Btuh/sq. ft.§Refer to figures 1 and 8. Headers shown are optional.‡‡All factory supplied headers use 3" system connections.Modules in excess of 10 should be piped in parallel in two or more batteries. Note: For higher capacities, specify correct combination of standard Caravanmodules shown.FOR LARGER SIZES, USE MULTIPLES OF THE ABOVE.©Slant/Fin Corp. 2012. Printed in the U.S.A. 912. Publication No. C-10-MG SLANT/FIN CORPORATION, Greenvale, N.Y. 11548 • Phone: (516) 484-2600Canada: Slant/Fin。
MGate5123Series1-port CANopen/J1939-to-PROFINET gatewaysFeatures and Benefits•Simultaneous protocol conversions from CANopen and J1939to PROFINETand SNMP•Supports PROFINET I/O device and SNMP agent•Supports CANopen master and J1939•Flexible deployment with Ethernet cascading and dual subnet•Embedded traffic monitoring/diagnostic information for easy troubleshooting•Easy device configuration via a web-based console•microSD card for configuration backup/duplication•Supports dual redundant DC power inputs and1relay output•CAN port with2-kV isolation protection•-40to75°C wide operating temperature models available•Developed according to IEC62443-4-2with Secure BootCertificationsIntroductionThe MGate5123is an industrial Ethernet gateway for converting CANopen or J1939to PROFINET network communications.To integrate existing CANopen or J1939devices onto a PROFINET network,use the MGate5123as a CANopen or J1939master to collect data and exchange data with the PROFINET IO controller.All models are protected by a rugged and compact metal housing and are DIN-rail mountable.The rugged design is suitable for industrial applications such as factory automation and other process automation industries.Easy ConfigurationThe MGate5123gateways are provided with a web console to make configuration easy without having to install an extra utility.In addition,HTTPS encryption of communication ensures higher network security.In most data-acquisition applications,configuration of CANopen devices can be time-consuming and increase costs.The MGate5123gateways provide EDS file import function and user can auto scan the CANopen devices to help complete the settings quickly.The MGate gateways provide software-configurable termination resistor settings for CANbus to reduce efforts by eliminating the need to open the chassis.Easy TroubleshootingThe MGate5123gateways provide a variety of maintenance functions to reduce troubleshooting time and cost,including LED indicators,protocol diagnostics,traffic monitor,and tag view.These tools help you capture and check data to easily identify the root cause of issues,especially during the installation stage.The MGate gateways also come with status monitoring and fault protection functions.The status monitoring function notifies a PLC/DCS/SCADA system when a CAN device gets disconnected or does not respond,in which case the process PLC/DCS gets the status of each end device and then issues alarms to notify operators.The fault protection function executes actions pre-defined by the user when a host gets disconnected to prevent the end devices from going offline for long periods of time.SpecificationsEthernet Interface10/100BaseT(X)Ports(RJ45connector)2Auto MDI/MDI-X connectionMagnetic Isolation Protection 1.5kV(built-in)Ethernet Software FeaturesIndustrial Protocols PROFINET IO DeviceConfiguration Options Web Console(HTTPS)Device Search Utility(DSU)Management ARPDHCP ClientDNSHTTPHTTPSSMTPSNMP TrapSNMPv1/v2c/v3TCP/IPUDPMIB RFC1213Time Management NTP ClientSecurity FunctionsAuthentication Local databaseEncryption HTTPSAES-128AES-256SHA-256Security Protocols SNMPv3SNMPv2c TrapHTTPS(TLS1.3)CAN InterfaceNo.of Ports1Connector Spring-type Euroblock terminalStandards ISO11898-2Baudrate CANopen:10kbps,20kbps,50kbps,125kbps,250kbps,500kbps,800kbps,1MbpsJ1939:250kbps,500kbps,1MbpsTerminator120ohmssoftware configurableSignals CAN_H,CAN_L,GND,Ext_CAN_H,Ext_CAN_L,CAN_ShieldCAN Software FeaturesIndustrial Protocols CANopen master,J1939CANopenMode MasterMax No.of Nodes64Max No.of Receive PDOs256Max No.of Transmit PDOs256SDOs SupportedInput Data Size2048bytesOutput Data Size2048bytesJ1939Max.No.of Commands256Input Data Size2048bytesOutput Data Size2048bytesPROFINETMode IO Device class BMax.No.of Master Connections2IO controllers(shared devices)Input Data Size1440bytes(bytes per IO Controller,total:2880bytes)Output Data Size1440bytes(bytes per IO Controller,total:2880bytes)MemorymicroSD Slot Up to32GB(SD2.0compatible)Power ParametersInput Voltage12to48VDCInput Current455mA(max)Power Connector Spring-type Euroblock terminalRelaysContact Current Rating Resistive load:2A@30VDCPhysical CharacteristicsHousing MetalIP Rating IP30Dimensions25x90x129.6mm(0.98x3.54x5.1in)Weight294g(0.65lb)Environmental LimitsOperating Temperature MGate5123:-10to60°C(14to140°F)MGate5123-T:-40to75°C(-40to167°F)Storage Temperature(package included)-40to85°C(-40to185°F)Ambient Relative Humidity5to95%(non-condensing)Standards and CertificationsSafety EN61010-2-201UL61010-2-201EMC EN61000-6-2/-6-4EMI FCC Part15B Class AEMS IEC61000-4-2ESD:Contact:8kV;Air:15kVIEC61000-4-3RS:80MHz to1GHz:10V/mIEC61000-4-4EFT:Power:4kV;Signal:2kVIEC61000-4-5Surge:Power:2kV;Signal:2kVIEC61000-4-6CS:150kHz to80MHz:10V/m;Signal:10V/mIEC61000-4-8PFMFFreefall IEC60068-2-31Shock IEC60068-2-27Vibration IEC60068-2-6IEC60068-2-64MTBFTime1,408,984hrs hrsStandards Telcordia SR332WarrantyWarranty Period5yearsDetails See /warrantyPackage ContentsDevice1x MGate5123Series gatewayDocumentation1x quick installation guide1x warranty cardDimensionsOrdering InformationModel Name No.of Serial Ports Operating Temperature MGate51231-10to60°C MGate5123-T1-40to75°C Accessories(sold separately)Wall-Mounting KitsWK-25Wall-mounting kit,2plates,4screws,25x43x2mm©Moxa Inc.All rights reserved.Updated Jun28,2023.This document and any portion thereof may not be reproduced or used in any manner whatsoever without the express written permission of Moxa Inc.Product specifications subject to change without notice.Visit our website for the most up-to-date product information.。
1P1Arktite heavy duty circuit breaking plugs and receptaclesIndustrial heavy duty Non-hazardous areasNEMA 4 WatertightApplications:Arktite ® circuit breaking plugs and receptacles are used:• To supply power to portable electrically operated devices such as motor generator sets, compressors, heating and cooling units, welders, conveyors, lighting systems and similar equipment• Where temporary power is needed, such as at trailers, building units, heavy machinery and similar equipment• Wherever electrical loads must be quickly disconnected from power source • In a typical installation, where a large machine utilizes a number of electrical motor drives and for ease of adjustment, removal, maintenance and replacement, each motor is connected by portable cord and Arktite receptacles rather than permanently wired• In areas where dust, dirt, moisture and corrosion are a problem• Indoors and outdoors in non-hazardous areas of chemical plants, processindustry facilities, meat packing plants, manufacturing plants and similar industrial locationsFeatures:• Circuit breaking – plugs through 100ampere rating may be disconnected under load; 150-400 ampere units are for service disconnect use only• Receptacles accept only plugs of the same amperage rating, style and number of poles, making it impossible to mismate, and provides for positive polarization • Extra wide electrical spacing allows for maximum safety• Insulator materials are the result of intensive testing; selection has beenmade based on highest dielectric strength, maximum mechanical and impactresistance, lowest moisture absorption and highest arc tracking resistance• A variety of installations is possible due to the availability of several types of back boxes• Designed to withstand rough usage and the effects of adverse environments • Reversible interiors – 30, 60 and 100 ampere (except 30 and 60 ampere, 5-pole); Arktite plug and receptacle interiors are interchangeable using a screwdriver, making it possible to feed a normally de-energized receptacle from an energized plug with usual Arktite safety; no energized contacts are exposedCertifications and compliances:• U L standards: 1203A , 1682, 1686• CSA standard: C22.2 No. 182.1• CE (LVD) 2006/95/EECBA APJ and NPJ plugs only.B Excludes 200A and 400A APR connectors.1P1PSplit pin contact design:• Provides nearly 360° of contact at every insertion, ensuring protection against heat rise and eliminating arcing on critical surfaces• Continuous contact over lengthand circumference of mated pinsprovides superior safety and long-term performance• Self-wiping at every insertion to prevent environmental contamination build-up Combination drive stainless steel hardware • Increases ease of installation by allowing for more than one option for installation tools • Stainless steel external hardware eliminates corrosion on critical components and extends product life Insulator assemblies• Unimpeded, easy access phase and ground terminals make wire termination quick and easy • Lug screws secured with tape to prevent them from vibrating loose and falling out during shipping Combination slot and hex mechanical lugs C • Increases ease of installation by allowing for more than one option for installation tools • Hex head allows for easy achievement of specified torque value Receptacle cover• Automatic weatherproof seal every time plug is disengaged • Field replaceable design allows for new cover to bethreaded on quickly and easilyArktite advantage features:Internal plug safety insulator• Plastic barrier between insulator body and metalhousing minimizes risk of energizing handle body due to stray conductor strands • Increases creepage and clearance protection CE marked• Offers a borderless solution with no additional inspection or documentation required for approval Lockout plug• Allows users to comply with OSHA lockout/tagout requirements • Ensures plug cannot be inserted into receptacle when maintenance is being performed downstream of power supply Tri-Lock cable grip• Three-piece design equally distributes grip around perimeter of cable • Cable jacket does not get pinched, eliminating potential for damage to internal conductors • Captive screws allow maximum extension of cord grip without risk of loose components Sure-Seal cable gland• Two gasket sizes fit entire cable range, reducing risk of improper assembly • Gasket ratches into Tri-Lock cable grip to provide environmental protection in high vibration areasThe additional features below arecalled out in the illustration on this page:123456The ground contact is bonded to thereceptacle housing (Style 2).Unimpeded, easy access phase and groundterminals make wire termination quick and easy.Grounding contacts that make first andbreak last in the unlikely event of keyway failure.An arc formed when the plug is beingremoved is instantly snuffed in the deep confined insulated arcing chamber.A detent spring forms a parallel groundingpath through the metallic plug sleeve and receptacle housing and is the first contact to make and the last to break.The plug sleeve is keyed to the receptacleto prevent mispolarization.78910111213The gasketing system providesunsurpassed watertight integrity (NEMA 4).All aluminum Uni-Shell ™ constructionprovides superior strength in abusive environments.The Tri-Lock ™ cable grip has three-piecedesign that equally distributes gripping power around perimeter of cable. Cord jacket does not get pinched, eliminating potential for damage to both internal conductors and external cable jacket. Cable grip is located inside plug housing, eliminating corrosion of vital hardware and making plug maintenance easy.The unique Sure-Seal ™ cable gland hastwo gasket sizes which fit entire range of cable diameters, reducing risk of improper assembly. The gasket ratchets into the Tri-Lock cable grip to prevent plug from turning or loosening in high vibration areas.Wrenching surfaces make Arktite plugsquick and easy to assemble.Smooth and contoured design of plughousing eliminates occurrence of cable grip snagging or breaking off. Tri-Lock screws are captive so cable grip cannot come apart during assembly. Prevents critical screws from getting lost during installation.Plastic sleeve between insulator body andhousing minimizes possibility of electrical shock in event of ground failure. Increases creepage and clearance protection.Plug housing• Smooth design eliminates occurrence of cable grip snagging or breaking off • Houses Tri-Lock cable grip to eliminate corrosion of vital hardware and increase ease of maintenance C 60, 100 and 150A offering.Arktite heavy duty circuit breaking plugs and receptaclesIndustrial heavy duty Non-hazardous areasNEMA 4 Watertight1P1Grounding – Style 1 vs. Style 2:Eaton’s Crouse-Hinds series Arktite devices utilize two methods, or styles, for completing the grounding circuit in plugs and receptacles. NEC reference 250.138 (A) and (B).Style 1 – metallicA Style 1 plug is one in which the groundingconductor in the flexible cable is bonded tothe plug sleeve by a pressure connector. AStyle 1 receptacle is one which is groundedby virtue of the fact that it is an integral partof a grounded conduit system. On insertion,the plug sleeve makes contact with detentsprings of the grounded receptacle housingbefore line and load poles engage, and onwithdrawal, remains in contact until afterline and load poles disengage. Therefore,exposed metal parts of the portableequipment or plug are suitably grounded.Style 1ground conductorattaches to shellStyle 2 – metallicA Style 2 metallic housing plug is onein which the grounding conductor inthe flexible cable is bonded to the extra(grounding) pole and metal plug sleeve bya pressure connector. A Style 2 metallichousing receptacle is one in which the extra(grounding) pole is electrically connectedto the equipment grounding conductorand the metal receptacle housing whichitself is grounded by virtue of the fact thatit is an integral part of a grounded conduitsystem. In Style 2 non-metallic housingplugs and receptacles, the extra pole is usedfor grounding since the housings are non-conductive.MetalshelledtypeStyle 2ground conductorattaches to contact,which is bonded toshellStyle 2 – non-metallicIn a Style 2 receptacle, the groundingconnection is made before line and loadpoles engage, and is broken after the lineload poles disengage. Furthermore, uponinsertion, the plug sleeve of metal shelledunits makes contact with detent springs ofthe grounded receptacle housing before lineand load poles engage, and on withdrawal,remains in contact until after line and loadpoles disengage. Therefore, exposed metalparts of the portable equipment or plug aresuitably grounded.Made ofnon-metallicKrydonmaterial Arktite heavy duty circuit breakingplugs and receptaclesIndustrial heavy dutyNon-hazardous areasNEMA 4 Watertight1P1PD150A, 200A and 400A rated units are for service disconnect use only.The mating plug has a cast groovelocated on the outside of the plug sleeve. This groove lines up with the raised rib.Arktite receptacles have a cast raised rib located inside the receptacle sleeve. The location of the rib is in a specific relationship to the receptacle insulator that houses the contacts.Standard materials:• Metallic receptacle housings, plug and cord connector bodies – high impact strength copper-free aluminum• Non-metallic receptacles, plugs and cord connectors – Krydon fiberglass-reinforced polyester• Back boxes (20, 30, 60, 100, 150, 200amperes) – cast aluminum; 400 amperes – Feraloy iron alloy• Insulation (metallic products) (2-, 3-, 4-pole) 30, 60, 100, 200, 400 amperes – fiberglass-reinforced polyester; 20, 30 amperes (5-pole) – melamine• Contacts: pressure, solder, binding screw – brass; crimp/solder 20, 30, 60, 100amperes – leaded red brass; crimp/solder 150, 200, 400 amperes – telurium copperStandard finishes:• Feraloy – electrogalvanized and aluminum acrylic paint• Aluminum – natural• Krydon fiberglass-reinforced polyester – gray• Fiberglass-reinforced polyester insulation – (red)• Melamine – natural (brown)• Brass – natural• Leaded red brass – electro-tin-plateAccessories:• A ccessories include a variety of angle adapters, panel adapters and back boxes for Arktite receptacles (see pages 697-700)• Included throughout Section 1P are wire mesh cable grips and protective caps for ArktiteplugsTypical installationOptions:Description Suffix • Reverse service ...................................S22 Receptacle assembled with plug interior(exposed contacts); plug assembled with receptacle interior (recessed contacts)For applications where plug is energized to feed normally de-energized receptacle Available on 30A-400A units• Special polarity .......................................S4 Receptacle interior rotated 221/2° to right andplug changed to match (see photo at right)For use where two or more receptacles of thesame ampere rating, style and number of poles are to be installed in the same area for use on different voltages and/or frequenciesPrevents insertion of a plug in a receptacle with different electrical rating Available on 20A-400A units• Corro-free epoxy powder finish foradded corrosion resistance................S752Available on 20A-400A unitsArktite heavy duty circuit breaking D plugs and receptaclesIndustrial heavy duty Non-hazardous areasNEMA 4 Watertight1P1E 150A, 200A and 400A rated units are for service disconnect use only.F Horsepower ratings are based on Eaton’s Crouse-Hinds Division testing in which locked rotor currents were interrupted by withdrawing the plug from the receptacle. It is highlyrecommended, however, that such use be limited to emergency conditions only, and that a horsepower rated switch be used for motor disconnect.G This guide is for reference only. Consult your local electrical codes before installation.H Eaton’s Crouse-Hinds Division does not recommend our plug and receptacle be used for disconnect under load.I Do not use wire size smaller than minimum size recommended.J Smaller sizes may be used with well reducers – information available upon request.Horsepower ratings:Locked rotor interruptingMaximum horsepower for plug and receptacle combinations by input voltage G :The following values are typical horsepower ratings based on NEC Article 430 tables. HP ratings are based on the largest conductor size for each plug and receptacle combination per the wire size table below.Wire sizes:The table below lists the diameter of the wire recess in Arktite plug and receptacle contacts so that maximum size of bare conductor can be figured. Range of wire sizes shown in table is intended only as a guide. Depending on type of wire used (building wire, flexible or extra flexible cable) and its construction (number and size of strands), bare copper diameters vary widely.Diameter of wire recess in plug and receptacle contacts:Motor horsepower FAmperage plug and receptacle120V 240V480V600VSingle-phase electrical system30237.51020030602515Motor horsepower HAmperage plug and receptacle240V 480V 600V3015304020060125150Wire size IAmperage Contact type Diameter of recess Building Extra flex20Binding screw N/A #14 - #12#14 - #12Arktite heavy duty circuit breaking E plugs and receptaclesIndustrial heavy duty Non-hazardous areasNEMA 4 Watertight1P1PArktite heavy duty circuit breaking receptacles, plugs and connectors20A, 600 VAC/250 VDC, 50A -400 HzNEMA 4 WatertightA When used on systems less than 60 Hz, the receptacles, plugs and connectors are for disconnect use only.1PDimensions (in inches):ARE assemblyAR receptacle – spring doorAR receptacle – open and with capAPJ plugReceptacles with back boxOrdering information:ConfigurationHub sizeDescriptionCat. #1/”Spring door ARE2211ReceptaclesConfigurationDescriptionCat. #Spring door AR221PlugsConfigurationCable dia.DescriptionCat. #0.250 - 0.500”Fastening ring APJ2271ConnectorsConfigurationCable dia.DescriptionCat. #0.250 - 0.500”Connector APR2251For applicable 20A back boxes, see page 697.Hub Sizea1/”11/。