风量变送器EE75secCN
- 格式:pdf
- 大小:411.68 KB
- 文档页数:5
风管风速传感器/变送器______说明书______概述测量管道风速而进行研发的,安装使用简便,可用于任意形状的管道内,多点测量方式有效排除风管内紊流误差,采有热式测量原理,响应时间快,测量精度极高,能快速反应风速变化。
K26系列,风速的测量范围广,提供电流、电压和RS485信号输出,管道式带有探头长度可定制,安装方便。
能够满足客户的测量要求。
特点-高精度风速传感器-适用于各类智能建筑环境监控,暖通空调系统-先进的电路设计,测量精度高,性能稳定-外形简洁,易安装,性价比高-出厂标准校准应用-暖通空调-电子厂房-机房环境监控-动力环境监控-农业环境监控-气象环境监测-生物制药环境监控-机场,地铁站,酒店,博物馆,体育馆等技术参数风速测量精度:测量范围:响应时间:校准:±2%FS、±3%FS、±5%FS0~10m/s、0~15m/s、0~20m/s、0~30m/s <1s标准校准输出参数信号输出:4~20mA RL<400ohm0~10VDC RL>10k ohmRS485输出485参数信号类型:RS485类型:连接:地址:通讯协议:数据格式:波特率:RS485串口输出多点,半双工2线制,最大通讯距离1200米,端子直接连接1-254,通过开关/软件设置,广播地址为:0,默认地址为:1 MODBUS1起始位,8数据位,无奇偶,2终止位1200bit/s,2400bit/s,4800bit/s,9600bit/s,19200bit/s,28800bit/s,38400bit/s,通过软件设置,默认值为:9600bit/s能耗供电电源:电流型24VDC±10%电压型24VDC±10%RS48510~28VDC接线方式接线端子:线缆规格:5.0mm间距,M3钢螺丝,0.2Nm扭矩,0.02欧姆接触电阻24~18AWG(0.2~1.0mm2),剥线长度6-7mm环境工作环境:温度-20 (80)湿度0...99%RH,无冷凝储存环境:温度-20 (80)湿度0-95%RH,无冷凝防护等级外壳防护等级:探头防护等级:防火等级:电磁兼容:IP65参考IEC529–598/GB700–86/GB4208 IP20参考IEC529–598/GB700–86/GB4208 V-0参考UL94参考GB/T13926,EN61000-6-2,EN61000-6-3材料与颜色外壳:探头长度:重量:ABS(浅蓝色)常用长度为200mm,长度可定制约150g(整机重量)外形尺寸(单位:mm)安装方式管道安装示意图安装说明:1、使用螺丝刀打开上壳的4个螺丝,取下上壳。
EE65/EE66系列测量原理:基于热膜风速仪原理,传感元件为E+E 公司特殊设计。
产品特点:•接近0m/s 空气速率的准确测量•由于在较宽范围内无方向依赖性,使安装方便简单•较好的抗尘能力•通过跳线连接可以选择测量范围、输出方式及反应时间•可配备液晶显示,反映当前测量数值典型应用:•楼宇系统•实验室•暖通空调系统•展览馆、博物馆风速变送器0~1m/s 0~1.5m/s 0~2m/s0~10m/s 0~15m/s 0~20m/s测量范围*¹0~10V ,-1mA < I L< 1mA4~20mA ,R L < 450Ω(三线)0~10V ,-1mA < I L < 1mA 4~20mA ,R L < 450Ω(三线)输出信号*¹0~1m/s ±(0.06m/s+2%读数)0~1.5m/s ±(0.07m/s+3%读数)0~2m/s ±(0.1m/s+3%读数)0~10m/s ±(0.3m/s+3%读数)0~15m/s ±(0.3m/s+3%读数)0~20m/s ±(0.3m/s+4%读数)精度@20℃45%RH 1013hPa-30~+60℃储存温度-10~+50℃工作温度ABS / IP65,液晶显示/ IP40外壳/ 防护等级EN50081-2,EN50082-1,EN50082-2 CE 认证电磁兼容最大1.5mm²螺纹接头连接< 3%测量值(△α| < 10º)安装角度依赖性0.2s 或2s响应时间(@10m/s )最大值DC 150mA AC 90mA耗电流24VAC/DV ±10%供电电源EE66 *²EE65 *²产品型号技术参数技术参数::备注:1. 通过跳线进行选择,设置需要的测量范围;2. 带有液晶显示功能。
浅谈智能建筑变风量空调(VAV)自控系统江梦芷(广州市水电设备安装有限公司) 【摘 要】:变风量VAV系统(Variable A ir Volu me Sys2te m)是一种全空气空调方式,它根据室内负荷的变化或室内要求参数的改变自动调节空调系统的送风量,从而保证室内参数达到绿色环保舒适的要求。
VAV系统是提供舒适空调的最现代化高效能系统。
【关键词】:变风量(VAV)系统;监测;自控 【中图分类号】:T U83 【文献标识码】:B1 前言现代智能建筑空调系统的设计,把“提高人的舒适性”摆在第一位,运用高科技手段,将环境参数调整到对人最舒适的数值,充分体现了“科技以人为本”的真谛。
创造一个绿色环保、舒适、温馨而安全的工作环境。
同时其智能化系统在符合实际需要的前提下,应有适当的超前性,以满足未来的需求。
变风量系统(Variable A ir Volu me Syste m,VAV系统)是一种全空气空调方式,它根据室内负荷的变化或室内要求参数的改变自动调节空调系统的送风量,从而保证室内参数达到绿色环保舒适的要求。
VAV系统是提供舒适空调的最现代化高效能系统。
下面谈一下某国际金融广场的智能建筑变风量空调(VAV)自控系统。
2 变风量空调(VAV)系统的监测和控制主要浅谈下列系统211 冷源系统21111 控制设备内容监控设备监控内容冷却塔风机启停控制、运行状态、故障报警、手自动状态、水流状态指示、电动蝶阀开关控制冷冻水泵(变频)启停控制、运行状态、故障报警、手自动状态、变频控制、两侧压力监测、压差旁通调节冷却水泵启停控制、运行状态、故障报警、手自动状态、水流开关状态冷冻水供回水总管供回水温度、压力;回水流量;压差旁通调节冷却塔(变频)启停控制、运行状态、故障报警、手自动状态、电动蝶阀开关控制、蝶阀开度反馈、供回水温度膨胀水箱高低液位21212 控制说明冷冻站的监控包括冷冻水系统、冷却水系统、冷却塔系统、集水器和分水器、膨胀水箱的监控,由每天预先编排的时间程序来控制冷冻系统的启停和监视各设备的主要工作状态如下:★冷却塔风机的启停控制;★冷却塔风机的运行状态、故障报警以及手自动状态监测;★冷却塔风机的前置水流开关状态监测;★冷却塔风机的管路上电动蝶阀的开关控制及位置反馈;★冷却塔风机的供回水流量、温度的监测;★冷冻水泵及冷却塔的启停控制;★冷冻水泵及冷却水泵的运行状态、故障报警以及手自动状态和水流状态监测;★冷冻水泵的变频调节和压差旁通调节利用设置在横跨冷冻水泵的总水压差传感器与设定值相比较,调节水泵的变频器和调整压差旁通阀的开度,保证水泵在设定的水压差下运行。
风量测量试验装置一、产品名称:风量测量试验装置二、公司名称:东莞市环仪仪器科技有限公司三、产品简介:风量测量试验装置是根据IEC标准并采用日本先进技术研发制造的风量测试系统。
四、基本测试原理是:在测试风洞中模拟试品的实际工作状态(由辅助风机使试品出风口压力与要求的一致),然后测出风洞中喷嘴两侧的气压差,再由标准公式计算出此时对应的风速,最后乘以喷嘴面积和相关流量系数而得出风量。
该装置采用计算机自动测控方式,只需人工安装试品和更换喷嘴,测试一台试品全过程只需十分钟。
可以测绘静压与风量、风量与转速、电流、功率、效率等对应曲线。
还可以对试品在吸入和排出。
两种状态下进行测试。
具有方便快捷、稳定可靠、重现性好等特点。
满足相关产品的科研和生产过程中测试使用。
1.产品名称:风量测量试验装置2.型号规格: LSK-0665、LSK-06663.标准依据: GB/T14806和IEC61591以及相关产品标准。
4.适用产品: 散热风机、轴流扇、换气扇、吸油烟机等。
五、总体方案本方案不包括试验室建筑结构部分,该部分由用户根据标准要求自行建造。
1.试验室一般要求尺寸:4500(宽)×6000)(长)×2800(高)mm以上。
2.墙壁:光滑平整,没有影响气流的开孔(空调开孔不应直吹)。
3.地面:应保持地面平整。
4.温湿度:风量测量时试验室空气温度为 20℃±5℃、湿度为 30%-80%(用户自备空调器或除湿机)。
5.大气压:海拔不超过1000米的普通大气环境。
六、测试系统1、主要构成:风量测试风洞、辅助风机及风门调节机构、测控电气柜(包括变频电源、电参数测量仪、压力变送器、转速表等)、品牌电脑、打印机、试品升降台、试品安装法兰及测试风管。
2、系统功能:由计算机提示输入试品参数和测试相关数据后,便可实现全部自动测控功能:包括、风量测量;电压、电流、功率测量;转速测量、温湿度和大气压测量、测试过程提示、数据表格、相关曲线等。
目录一概述-------------------------------------------------------------------------------------------- 1二基本技术参数-------------------------------------------------------------------------------- 1三使用环境-------------------------------------------------------------------------------------- 1四安装顺序-------------------------------------------------------------------------------------- 2五风量仪控制面板----------------------------------------------------------------------------- 2六操作说明-------------------------------------------------------------------------------------- 2 1.开机--------------------------------------------------------------------------------------------- 2 2.校准(归零)--------------------------------------------------------------------------------- 33. 存储位置设置 --------------------------------------------------------------------------------- 34. 测量,保持和保存 --------------------------------------------------------------------------- 35. 数据查看,打印和上传 --------------------------------------------------------------------- 46. 单位换算 --------------------------------------------------------------------------------------- 47. 电脑连接 --------------------------------------------------------------------------------------- 48. 维修模式:(注意: 此模式用户不得修改.)-------------------------------------------- 6七保养与维护----------------------------------------------------------------------------------- 61、电池保养--------------------------------------------------------------------------------------- 62、仪器维护--------------------------------------------------------------------------------------- 7一 概述ACH3150型风量仪采用皮托管式原理对风压进行多点、多次自动检测,产生平均风量(m3/h和Ft3/min)具有测量精度高、操作简便、测量快速等特点。
EE65 – C典型应用特点概述 供电电源 SELV 24V AC/DC ± 20 % SELV = 可靠安全电压 电流消耗交流供电 最大150mA 直流供电 最大90mA 角度依赖性 < 测量值的3% (| Δα | < 10°时) 电缆规格 M16x1.5 电缆直径Ø 4.5 - 10 mm 电路连接 接线端子最大1.5 mm 2 (AWG 16)电磁兼容标准 EN 50081-1 EN 50082-1 EN 50082-2 外壳/防护等级 聚碳酸酯/IP65, Nema 4 带LC 显示器:IP401) 可通过跳线选择。
2) 响应时间是从风速变化开始到达到预期值的90%时测得的。
E E 65系列暖通空调用风速变送器EE65风速变送器是精确通风控制应用的理想选择。
它以创新的热膜风速计为工作原理。
益加义公司的薄膜传感器确保在低风速时仍保持高精度,而这是利用普通温度传感器或NTC 的传统风速计无法实现的。
而且,这种传感器较之其它的传感器对灰尘和污垢的敏感度更低,这样,测量就更可靠而维护成本却很低。
EE65 - A / BEE65系列提供电流或电压输出信号,用户可利用跳线选择测量范围和响应时间。
较低的角度依赖性使其安装更方便经济。
还有LCD 显示和带独立传感探头的型号可供选择。
暖通空调过程和环境控制技术数据测量值工作范围1) 0...10m/s 0...15m/s角度依赖性低 安装简便 可根据应用要求调整0...20m/s输出1)0 - 10 V -1 mA < I L < 1 mA0..10m/s / 0...15m/s / 0...20m/s4 - 20 mAR L < 450 Ω 精度(20°C ,45%RH 和1013hPa 时) 0.2...10m/s ± (0.2m/s + 3%*mv) 0.2...15m/s± (0.2m/s + 3%* mv)0.2...20m/s± (0.2m/s + 3%*mv)响应时间t 901) 2)typ. 4秒或typ. 0.2秒(恒温条件下)EE65 - C10%温度范围 探头工作温度:-25...50°C电路板工作温度: -10...50°C储存温度: -30...60°C尺寸A 型C 型标准电缆长度:B 型电路接图供电24 V AC/DC ± 20%V+ = 正极 GND = 负极AV = 风速输出+ ~- ~V / mAV+ GND AV123订货订货EE65-VB5-D02型号: 风速安装: 管道安装探头长度: 200mm 显示: 带LC 显示。
XE70 SERIEST6374/T6375FAN-COIL THERMOSTATS4-PIPE FAN-COIL CONTROLPRODUCT SPECIFICATION SHEETThe T6374 and T6375 are designed to control the valves, or the valves and the fan in 4-pipe fan-coil applications, with the possibility of also being used for control of split units andsmall air conditioners.The thermostat operates the on/off valves to provide controlat the desired setpoint temperature.The fan can also be controlled from the thermostat. It is wired to run continuously, and can be switched off with the system ON/OFF switch.Versions are available with a manual 3-SPEED FAN switch, and with a system ON/OFF switch.Heat/cool changeover operation is also possible on some versions. This function can be accomplished by a manually operated HEAT/ COOL switch on the front of the thermostat,or in some versions, automatically by means of a fixed deadband built into the thermostat between the heating and cooling setpoints.FEATURES∙Dual diaphragm sensing element ensures close temperature control for all loads and applications∙Attractive modern styling makes this thermostat ideal for locating in the occupied space, particularly inoffices or hotels∙Versions with heat anticipator, which improves temperature control in both heating and coolingoperation∙Thermostat mounts directly onto a wall or conduit box ∙Slide switches allow manual control of system operation and fan speed∙Versions available with fixed deadband between heating and cooling operation∙Optional extras available are :- range stops F42006646-001 (20 per pack, enough for10 thermostats)T6374/T6375 FAN-COIL THERMOSTATS 4-PIPE FAN-COIL CONTROLSetpoint range :10...30o C. By means of a large setpointdialSupply voltage :230 V~, 50...60 HzThermostatswitch:S.P.D.T.Performance :Typical differential 1 o C (heating &cooling) at 20o C at 50% load withanticipator connectedElectrical ratings :4(2) A, 230 V~Typical loads are fans, zone valves andrelaysOperational life :Greater than 100,000 cycles (all loads)for thermostat contacts at 230 V~ Greaterthan 6,000 operations for all manuallyoperated switchesMounting :Mounts directly onto wall or wall-box(mounting screws supplied) Wiring :Up to 9 screw-in terminals per unit,capable of accepting wires up to 1.5 mm2 Enclosure :Plastic 2-piece housingDimensions :85 x 130 x 40 mm (w x h x d). Protection class :IP30Environmentalrequirements:Operating temperature range 0 to 40o CShipping and storage temperature range-20 to 50o CHumidity range 0 to 90% rh, non-condensingApprovals : The XE70 range is CE, RoHs and WEEEcompliant. For regulatory information, DoC/ CoC D0046 is available on request.Product must be wired as shown for CEcompliance.DIMENSIONSINSTALLATIONOPERATIONSensing elementThe thermostat sensing element comprises two circular, flexible metal plates welded together at the rims and encapsulating a gas/liquid combination whose pressure changes in response to variations in temperature. This dual-diaphragm expands and contracts with ambient temperature changes to operate a snap-acting switch which controls the heating or cooling circuit.Heat anticipatorIt is recommended that the heat anticipator is always connected for both heating and cooling operation. LocationThe XE70 Series thermostat is the temperature control element in the fan-coil or air-conditioning system, and must be located in a position with good air circulation, on an inside wall about 1.5 m above the floor to sense the average temperature. Do not position the thermostat in draughts, near hot or cold air sources or where it will be affected by radiant heat from the sun or other appliances.Mounting the thermostatAny XE70 Series thermostat can be directly mounted on the wall or on a conduit box (see diagram). Mounting screws are supplied for both alternatives.Wiring the thermostatThe standard wiring access is via a hole in the base of the thermostat, near the top edge.IMPORTANT1. The installer must be a trained service engineer2. Disconnect the power supply before beginninginstallationSwitchesAll switches are slide switches for ease of operation.The ON/OFF switch is a system on/off switch, as it removes power from the thermostat.The FAN SPEED switch allows selection of 3 different fan speeds, 1 (low), 2 (medium), and 3 (high)The DPDT HEAT/COOL switch allows selection of either heating or cooling operation. There are 2 output terminals controlled by this switch.The HEAT/FAN/COOL switch allows selection of either heating or cooling operation, but also has an additional selection position which disables all outputs except that of the fan. The fan can be controlled separately, by the systemON/OFF switch.APPLICATIONT6374/T6375 FAN-COIL THERMOSTATS 4-PIPE FAN-COIL CONTROLHoneywell Control Systems Limited Newhouse Industrial EstateMotherwell ML1 5SB United KingdomWIRING。
风量、风压换算表
风量
风量是指风冷散热器风扇每分钟送出或吸入的空气总体积,如果按立方英尺来计算,单位就是CFM;如果按立方米来算,就是CMM,散热器产品经常使用的风量单位是CFM。
风量单位
CFS:Cubic Feet Per Second,立方英呎/秒(ft3/s)
CFM:Cubic Feet Per Minute,立方英呎/分(ft3/min)
CMS:Cubic Meter Per Second,立方公尺/秒(m3/s)
CMM:Cubic Meter Per Minute,立方公尺/分(m3/min)
CMH:Cubic Meter Per Hour,立方公尺/时(m3/h)
L/s:Liter Per Second,公升/秒(L/s)
L/min:Liter Per Minute,公升/分(L/min)
风量换算表
风压
为进行正常通风,需要克服风扇通风行程内的阻力,风扇必须产生克服送风阻力的压力,测量到的压力的变化值称为静压,即最大静压与大气压的差压。
它是气体对平行于物体表面作用的压力,静压是通过垂直于其表面的孔测量出来的。
风压单位
N:Newton,1n=0.101097Kgf
Pa:Pascal,Pa=N/m2
mmAq:Aq=Aqua(水柱)简称
mmAq又称mmH2O;1mmAq=1Kg/m2
atm:大气压;一大气压等于在0℃干燥状态下760mmHg的压力。
因水银重量是水的13.5947倍,所以一大气压又等于10332mmH2O 的压力
bar:1 bar=0.00001Pa=10-5Pa
风压换算表。
迪泰科特风筒风量传感器使用说明(原创实用版)目录一、迪泰科特风筒风量传感器简介二、传感器的安装与使用1.安装位置2.安装步骤3.使用注意事项三、传感器的维护与保养1.维护周期2.维护内容3.保养方法四、传感器故障处理与安全措施1.常见故障及处理方法2.安全措施正文一、迪泰科特风筒风量传感器简介迪泰科特风筒风量传感器是一款用于测量风筒风量的高科技产品,广泛应用于煤矿、隧道、地铁等工程的局部通风系统中。
通过对风量的实时监测,能够确保通风系统的正常运行,为工作人员提供安全的工作环境。
二、传感器的安装与使用1.安装位置迪泰科特风筒风量传感器应安装在局部通风机的出风口,距离出风口不大于 50m。
在安装时,需要保证传感器不受到尘埃、水汽等影响,以确保测量结果的准确性。
2.安装步骤(1)首先,将传感器安装在风筒上,确保安装牢固;(2)然后,将传感器的电缆与局部通风机的电源连接;(3)最后,进行通电试验,检查传感器是否正常工作。
3.使用注意事项(1)在使用过程中,应避免传感器受到撞击、摔落等损坏;(2)保持传感器周围环境的清洁,防止尘埃、水汽等进入传感器;(3)避免在高温、高湿的环境中使用传感器,以免影响其使用寿命。
三、传感器的维护与保养1.维护周期迪泰科特风筒风量传感器的维护周期为一年。
在一年内,应定期对传感器进行清洁、保养,以确保其正常工作。
2.维护内容(1)清洁传感器外表,去除灰尘、油污等;(2)检查传感器电缆是否有破损、断路等情况;(3)检查传感器接头是否有松动、接触不良等现象。
3.保养方法(1)使用专用清洁剂清洁传感器外表;(2)定期检查电缆,如有破损应及时更换;(3)定期紧固接头,确保接触良好。
四、传感器故障处理与安全措施1.常见故障及处理方法(1)传感器无法正常工作:检查电缆是否接触良好,如有问题及时更换电缆;(2)传感器测量结果不准确:检查传感器周围环境是否清洁,如有尘埃、水汽等影响,及时清理;(3)传感器出现短路现象:检查传感器电缆是否破损,如有问题及时更换。
迪泰科特风筒风量传感器使用说明一、简介迪泰科特风筒风量传感器是一种用于测量风量的传感器,主要应用于工业生产、实验室测试等领域。
它采用先进的传感技术,能够准确、快速地测量气流的速度和压力,为用户提供了一个可靠的工具。
在本文中,我们将深入探讨迪泰科特风筒风量传感器的使用说明,帮助用户更好地了解和使用这一设备。
二、测量原理迪泰科特风筒风量传感器主要利用沟通测速原理进行测量。
当气流通过传感器时,传感器内的沟通受到气流的冷却作用,从而导致沟通温度降低。
通过测量沟通冷却前后的温度差,就可以计算出气流的速度和压力。
这种测量原理具有高精度、快速响应的特点,适用于不同环境下的气流测量。
三、安装及使用步骤1. 安装位置选择:在安装风量传感器时,应选择在气流稳定的位置进行安装,避免强烈的湍流和涡流对测量结果的影响。
应避免阳光直射和雨淋,以免影响传感器的正常使用。
2. 连接电源:将风量传感器与电源相连接,确保电源稳定。
在连接过程中,要注意保持线路的整洁,避免出现接触不良或短路等问题。
3. 设置参数:根据实际需要,可以对风量传感器的测量范围、灵敏度等参数进行设置,以获得更准确的测量结果。
这需要依据具体的使用手册进行操作,确保参数设置正确。
4. 数据采集:使用数据采集设备连接风量传感器,进行数据采集和分析。
在数据采集过程中,要注意记录环境温湿度等影响因素,以便后续分析和校正。
四、注意事项1. 避免碰撞:在使用风量传感器时,要避免碰撞和摔落,确保传感器的外壳和内部结构完好无损。
2. 定期校准:为了确保测量结果的准确性,风量传感器需要定期进行校准。
校准周期一般为半年至一年一次,具体频率需根据实际使用情况进行确定。
3. 清洁保养:定期对风量传感器进行清洁和保养,以确保传感器的散热性能和灵敏度。
在清洁过程中,要注意避免使用化学溶剂,以免对传感器造成损害。
五、个人观点迪泰科特风筒风量传感器作为一种先进的气流测量设备,具有广泛的应用前景。