空气过滤除菌流程
- 格式:doc
- 大小:126.00 KB
- 文档页数:23
两级冷却空气过滤除菌的工艺流程英文回答:Two-stage cooling air filtration and sterilization process typically involve several steps to ensure the air is effectively cleaned and free of harmful microorganisms. The process starts with the intake of ambient air, which is then passed through a pre-filter to remove large particles such as dust and pollen. This initial filtration step helps protect the subsequent stages of the process and ensures the longevity of the system.After passing through the pre-filter, the air enters the first stage of filtration, where a high-efficiency particulate air (HEPA) filter is used to capture smaller particles. HEPA filters are designed to trap 99.97% of particles that are 0.3 microns in size or larger, making them highly effective in removing allergens, bacteria, and viruses from the air.Following the first-stage filtration, the air is then directed to the second stage, which involves the use of an ultraviolet (UV) light sterilization system. UV light is known for its ability to kill microorganisms by disrupting their DNA, rendering them unable to replicate. This step provides an added layer of protection against airborne pathogens, further ensuring the cleanliness of the air.After passing through the UV light sterilization system, the air undergoes a final filtration process, typically using a carbon filter. Carbon filters are effective in removing odors, volatile organic compounds (VOCs), andother gaseous pollutants, leaving the air fresh and clean.The entire process is designed to provide comprehensive air cleaning and sterilization, ensuring that the air circulating within the environment is of the highest quality. By combining multiple filtration and sterilization methods, two-stage cooling air filtration systems are ableto achieve optimal results in maintaining indoor air quality.中文回答:两级冷却空气过滤除菌的工艺流程通常涉及多个步骤,以确保空气被有效清洁并且没有有害微生物。
第1篇一、目的为确保实验过程中微生物的去除效果,防止实验结果受到微生物污染,特制定本规程。
本规程适用于所有需要过滤除菌的实验操作。
二、适用范围本规程适用于实验室中所有需要进行过滤除菌的操作,包括但不限于水样、空气、培养基等。
三、职责1. 实验室负责人负责制定、修订和发布本规程。
2. 实验室工作人员负责执行本规程,并接受监督。
3. 监督员负责监督实验室工作人员执行本规程。
四、操作规程1. 准备工作1.1 确保实验室内环境整洁,无污染源。
1.2 检查过滤设备,包括过滤器、滤膜、过滤器支架等,确保其完好无损。
1.3 检查实验用仪器设备,如超净工作台、生物安全柜、无菌操作室等,确保其正常运行。
1.4 检查实验用试剂、耗材,确保其质量合格。
2. 过滤除菌操作步骤2.1 准备实验用液体或气体,确保其无污染。
2.2 将待过滤的液体或气体通过预处理系统,如粗滤、砂滤等,去除大颗粒杂质。
2.3 将预处理后的液体或气体通过过滤器进行除菌过滤。
2.3.1 将过滤器安装在过滤器支架上,确保安装牢固。
2.3.2 将滤膜安装在过滤器上,确保滤膜完好无损。
2.3.3 将待过滤的液体或气体通过过滤器,确保流速适宜。
2.4 过滤完成后,关闭过滤器进水阀门,取出滤膜,检查滤膜是否完好。
2.5 将滤膜放入消毒液中浸泡消毒,确保消毒彻底。
2.6 将消毒后的滤膜取出,晾干后备用。
3. 无菌操作3.1 在进行过滤除菌操作时,应严格遵守无菌操作规程,确保操作环境、仪器设备、试剂耗材等均处于无菌状态。
3.2 操作人员应穿戴无菌衣、口罩、帽子、消毒鞋等防护用品。
3.3 操作过程中,应避免直接接触滤膜,以防污染。
3.4 操作完毕后,应及时清理实验台面,消毒操作区域。
4. 检查与记录4.1 检查过滤除菌效果,可采用显微镜观察、细菌培养等方法。
4.2 记录过滤除菌操作过程,包括操作人员、操作时间、过滤设备、滤膜型号、流速等。
五、异常情况处理5.1 若发现过滤除菌效果不理想,应立即停止操作,查找原因,并采取措施解决。
空气介质过滤除菌的工艺流程英文回答:Air filtration and disinfection processes are essential in maintaining clean and safe indoor environments. There are several steps involved in the process of filtering and disinfecting air in a medium.1. Pre-filtration: The first step in the process ispre-filtration, which involves removing larger particles such as dust, pollen, and pet dander. This is typically done using a mechanical filter, such as a high-efficiency particulate air (HEPA) filter. These filters are designed to capture particles as small as 0.3 microns with a high efficiency.2. Activated carbon filtration: After pre-filtration, the air passes through an activated carbon filter. This filter helps to remove odors, gases, and volatile organic compounds (VOCs) from the air. Activated carbon has a largesurface area that can adsorb these contaminants, improving the overall air quality.3. High-efficiency filtration: Following activated carbon filtration, the air is further purified using high-efficiency filters. These filters are designed to capture smaller particles, including bacteria and viruses. HEPA filters are commonly used in this step to achieve a high level of filtration efficiency.4. Ultraviolet (UV) disinfection: In addition to filtration, UV disinfection is often employed to kill or inactivate microorganisms, including bacteria and viruses. UV light has germicidal properties that can destroy the DNA or RNA of these microorganisms, rendering them unable to reproduce and cause harm. UV lamps are strategically placed within the air handling system to ensure maximum exposure of the air to the UV light.5. Electrostatic precipitation: Another method used for air disinfection is electrostatic precipitation. This process involves charging particles in the air andcollecting them on oppositely charged plates or filters. The charged particles, including microorganisms, are attracted to the charged plates and removed from the air stream. This method is effective in removing both larger particles and smaller microorganisms.6. Ozone generation: Ozone is a powerful oxidizing agent that can effectively kill bacteria, viruses, and other microorganisms. Ozone generators are sometimes usedin air purification systems to produce ozone, which is then introduced into the air stream. However, it is important to note that ozone can be harmful to humans and should be used with caution and proper ventilation.7. Final filtration: The last step in the process is the final filtration, which ensures that any remaining particles or microorganisms are removed from the air. This step usually involves the use of HEPA filters or otherhigh-efficiency filters to achieve the desired level of air cleanliness.In conclusion, the process of filtering anddisinfecting air in a medium involves several steps, including pre-filtration, activated carbon filtration, high-efficiency filtration, UV disinfection, electrostatic precipitation, ozone generation (if applicable), and final filtration. These processes work together to remove particles, odors, gases, and microorganisms from the air, ensuring a clean and healthy indoor environment.中文回答:空气过滤和除菌工艺是保持室内环境清洁和安全的关键。
空气过滤除菌流程空气过滤除菌流程是按生产对无菌空气要求具备的参数,如无菌程度、空气压力、温度等,并结合吸气环境的空气条件和所用除菌设备的特性,根据空气的性质而制定的。
要把空气过滤除菌,并输送到需要的地方,首先要提高空气的能量即增加空气的压力,以克服设备和管道的阻力。
这就需要使用空气压缩机或鼓风机。
而空气经压缩后,温度会升高,冷却后会释出水分,空气在压缩过程中又有可能夹带机器润滑油雾,这些都使无菌空气的制备流程复杂化。
对于风压要求低,输送距离短,无菌要求也不高的场合,如洁净工作室、洁净工作台等,以及具有自吸作用的发酵系统,如转子式自吸发酵罐等,只要数十到数百帕的空气压力就可以满足需要。
在这种情况下,可以采用普通的离心式鼓风机增压,具有一定压力的空气通过一个大过滤面积的过滤器,以很低的流速进行过滤除菌,这样气流的阻力损失就很小。
由于空气的压缩比很小,空气的温度升高不多,相对湿度变化不大,如果空气过滤效率比较高,经一、二级过滤后就能符合无菌空气的要求。
这样的除菌流程比较简单,关键在于离心式鼓风机的增压与空气过滤的阻力损失要配合好,以保证空气过滤后还有足够的压力推动空气在管道和无菌空间中流动。
要制备无菌程度高、压力高的无菌空气,就要采用空气压缩机来增压。
由于空气压缩比大,空气的各种参数变化大,这就需要额外增加一系列附属设备。
这种流程的制定应根据所在地的地理位置、气候环境和设备条件等作全面考虑。
如在环境污染比较严重的地方,要考虑改变吸风的条件,以降低过滤器的负荷,提高空气的无菌程度;在温暖潮湿的南方,要加强除水设施,以确保过滤器的最大除菌效率和使用寿命;在压缩机耗油严重的流程中要加强油雾的去除。
另外,空气被压缩后温度升高,需将其迅速冷却,以减小压缩机的负荷,保证机器的正常运转。
空气冷却将析出大量的冷凝水形成水雾,必须将其除去,否则带入过滤器将会严重影响过滤效果。
一般要求压缩空气的相对湿度为ψ=50%~60%时通过过滤器为好。
要保持过滤器在比较高的效率下进行过滤,并维持一定的气流速度和不受油、水的污染,需要一系列的加热、冷却及分离和除杂设备来保证。
空气过滤除菌有多种流程,下面是几个较为典型的设备流程。
(一)两级冷却、加热除菌流程具体流程见图4-3,这是一个比较完善的空气除菌流程,可适应各种气候条件,能充分地分离油水,使空气达到低的相对湿度下进入过滤器,以提高过滤效率。
该流程的特点是两次冷却、两次分离、适当加热。
两次加热、两次分离油水的好处是能提高传热系数,节约冷却水,油水分离得比较完全。
经第一冷却器冷却后,大部分的水、油都已结成较大的颗粒,且雾粒浓度较大,故适宜用旋风分离器分离。
第二冷却器使空气进一步冷却后析出一部分较小雾粒,宜采用丝网分离器分离,这样发挥丝网能够分离较小直径的雾粒和分离效率高的作用。
通常,第一级冷却到30~35?,第二级冷却到20~25?。
除水后,空气的相对湿度仍较高,须用丝网分离器后的加热器加热空气,使其相对湿度降低至50~60%,以保证过滤器的正常运行。
两级冷却、加热除菌流程尤其适用潮湿的地区,其他地区可根据当地的情况,对流程中的设备作适当的增减。
一些对无菌程度要求比较高的微生物工程产品,均使用此流程。
(二)冷热空气直接混合式空气除菌流程如图4-4。
从流程图可以看出,压缩空气从贮罐出来后分成两部分,一部分进入冷却器,冷却到较低温度,经分离器分离水、油雾后与另一部分未处理过的高温压缩空气混合,此时混合空气已达到温度为30~35?,相对湿度为50~60%的要求,再进入过滤器过滤。
该流程的特点是可省去第二次冷却后的分离设备和空气加热设备,流程比较简单,利用压缩空气来加热析水后的空气,冷却水用量少等。
该流程适用于中等含湿地区,但不适合于空气含湿量高的地区。
由于外界空气随季节而变化,冷热空气的混合流程需要较高的操作技术。
(三)高效前置过滤空气除菌流程图4-5为高效前置过滤除菌的流程示意图。
它采用了高效率的前置过滤设备,利用压缩机的抽吸作用,使空气先经中、高效过滤后,再进入空气压缩机,这样就降低了主过滤器的负荷。
经高效前置过滤后,空气的无菌程度已相当高,再经冷却、分离,进入主过滤器过滤,就可获得无菌程度很高的空气。
此流程的特点是采用了高效率的前置过滤设备,使空气经过多次过滤,因而所得的空气无菌程度比较高。
(四)利用热空气加热冷空气的流程图4-6为热空气加热冷空气的流程示意图。
它利用压缩后热空气和冷却后的冷空气进行交换,使冷空气的温度升高,降低相对湿度。
此流程对热能的利用比较合理,热交换还可以兼做贮气罐,但由于气—气交换的传热系数很小,加热面积要足够大才能满足要求。
由以上较为典型的无菌空气制备流程可以看出,无菌空气制备的整个过程包括两部分内容:一是对进入空气过滤器的空气进行预处理,达到合适的空气状态(温度、湿度),二是对空气进行过滤处理,以除去微生物颗粒,满足生物细胞培养需要。
空气滤清器加工制作流程2009-06-10 16:431、空气滤清器的功能为了使发动机正常运作,必定要有大量的纯净空气吸入。
如果空气中对发动机有害的物质(灰尘、胶质、氧化铝、酸化铁等)被吸入,缸筒、活塞组件会增加负担,使筒、活塞组件异常磨损,以至混入发动机机油,更大幅度的磨损,导致发动机性能劣化、缩短发动机寿命,防止发动机磨损。
同时空气滤清器还具有消音功能。
空气滤清器一般要求10000公里换一次,才能达到最佳使用效果。
2、空气滤清器应有的功能(1)维持性能的品质条件:A过滤性能度高(清净效率);B过气抵抗性低;C寿命长久(捕捉大量灰尘)。
(2)具有耐久性、合理性之品质条件:A耐压性、耐振动性、耐久性高,不会将灰尘渗漏;B耐低温性、耐高温性、耐水性,滤纸、接着剂、橡胶等不易入侵;C装卸简单轻巧。
3、空气滤清器的分类(1)按形状分类:A圆帽型(17801-43010);B角型(17801-74010)C筒型(17801-58010)。
(2)按滤材分类:A干式滤纸式,纸多而薄,多重过滤面积,滤纸带纹,是可延长寿命的滤纸。
厚度为0.3mm,过滤孔径为28μ,过滤效果为99-99.9%;B湿式滤纸式,,滤纸中含有油,耐焦化性优,主要是让灰尘附着,不断地反复过滤,中途不必清扫.厚度为0.8 mm ,过滤孔径为38μ,过滤效果为98-99.5%;C不织布式(无纺布),密度厚的勾织(三层),可捕捉各层面的尘粒子,厚度为3.2 mm,过滤孔径65μ,过滤效果为97-99%主要用于乘用车;D油槽式;E金属网式;F泡棉式。
(3)按成型的材料分类:上、下盖板为铁(PT)、PP 、 PU、树脂(一体成型)4、空气滤清器的生产流程(1)PU制品:折纸?烧烤滤纸?接合(组合)?上模浇灌PU料?加温成型?修剪检测?包装入库(2)不织布PP制品:折布?上模浇灌PP料?检测?装配胶圈?包装入库(3)滤纸PP、PT制品:折纸?烧烤滤纸?接合(组合)?上、下顶板途胶水?组装?加温成型?粘胶圈、浸油?包装入库5、其它(1)滤纸烧烤后的好处:A增加滤纸的硬度,在过滤中不使滤纸变形;B去除滤纸中的水分;使滤纸过滤效果达到最佳。
(2)空气滤清器风叶的作用:让空气进入后形成一股气流,使附在滤纸上的灰尘脱落,多用于干式滤纸滤清器上。
(3)检测滤纸烧烤效果的方法:试剂反应效果酊酮无色正常酊酮白色烧烤不够酊酮黑色烧烤过久(4)PP制品外观检查方法:滤纸、滤布内侧披锋(漏胶)1 mm以下为优良品1 mm以上5 mm以下、5处以内为良品10 mm以下、1处为良品10 mm以上重做(不良品)空气过滤器科技名词定义中文名称:空气过滤器英文名称:air filter定义1:滤除压气机进口空气中的尘粒、盐分等杂质的设备。
应用学科: 电力(一级学科);汽轮机、燃气轮机(二级学科) 定义2:能清除空气中灰尘及杂质的器件。
应用学科:机械工程(一级学科);实验室仪器和装置(二级学科);气候环境试验设备-气候环境试验设备零部件及附件(三级学科)以上内容由全国科学技术名词审定委员会审定公布求助编辑百科名片空气过滤器空气过滤器(Air Filter)是指空气过滤装置,一般用于洁净车间,洁净厂房,实验室及洁净室,或者用于电子机械通信设备等的防尘。
有初效过滤器,中效过滤器,高效过滤器及亚高效等型号。
各种型号有不同的标准和使用效能。
目录概述空气过滤器的发展过滤器本身的设计也取得了显著进展空气过滤器的作用空气过滤器的工作原理空气过滤器的主要性能指标过滤精度流量特性分水效率分类初效空气过滤器中效空气滤器高效空气过滤器空气过滤器如何过滤空气空气过滤器的相关行业标准超期使用危害常规技术参数空气过滤器的设计重点本体设计导流板设计伞形挡水板设计滤芯、水杯和保护罩设计排水阀设计设计后续处理概述空气过滤器的发展过滤器本身的设计也取得了显著进展空气过滤器的作用空气过滤器的工作原理空气过滤器的主要性能指标过滤精度流量特性分水效率分类初效空气过滤器中效空气滤器高效空气过滤器空气过滤器如何过滤空气空气过滤器的相关行业标准超期使用危害常规技术参数空气过滤器的设计重点本体设计导流板设计伞形挡水板设计滤芯、水杯和保护罩设计排水阀设计设计后续处理展开编辑本段概述在气动技术中,空气过滤器、减压阀和油雾器称为气动三大件。
为得到多种功能,往往将这三种气源处理元件按顺序组装在一起,称为气动三联件,用于气源净化过滤、减压和提供润滑。
三大件的安装顺序按进气方向依次为空气过滤器、减压阀、油雾器。
三大件是多数气动系统中不可缺少的气源装置,安装在用气设备近处,是压缩空气质量的最后保证.其设计和安装,除确保三大件自身质量外,还要考虑节省空间、操作安装方便、可任意组合等因素。
编辑本段空气过滤器的发展空气过滤器的原型是人们为保护呼吸而使用的呼吸保护器具。
据记载,早在一世纪的罗马,人们在提纯水银的时候就用粗麻制成的面具进行保护。
在此之后的漫长时间里,空气过滤器也取得了进展,但其主要是作为呼吸保护器具用于一些危险的行业,如有害化学品的生产。
1827年布朗发现了微小粒子的运动规律,人们对空气过滤的机理有了进一步的认识。
空气过滤器的迅速发展是与军事工业和电子工业的发展紧密相关的。
在第一次世界大战期间,由于各种化学毒剂的使用,以石棉纤维过滤纸作为滤烟层的军用防毒面具应运而生。
玻璃纤维过滤介质用于空气过滤于1940年10月在美国取得专利。
50年代,美国对玻璃纤维过滤纸的生产工艺进行了深入的研究,使空气过滤器得到了改善和发展。
60年代,HEPA过滤器问世;70年代,采用微细玻璃纤维过滤纸作为过滤介质的HEPA过滤器,对013微米粒径的粒子过滤效率高达99.9998%。
八十年代以来,随着新的测试方法的出现、使用评价的提高及对过滤性能要求的提高,发现HEPA过滤器存在着严重的问题,于是又产生了性能更高的ULPA过滤器。