PVC 无碳 软件存储说明书
- 格式:pptx
- 大小:2.06 MB
- 文档页数:13
Data SheetFUJITSU ETERNUS SF V16.5Storage Management SoftwareCentral console and advanced management functions forETERNUS DX disk storage environments.ETERNUS SF Storage Management Software The comprehensive and flexible datamanagement for ETERNUS DX storage systems offers convenient, consistent and powerful tools with enterprise class functionalities even for the entry class. Innovative and advanced functions increase operational efficiency and help to implement appropriate service levels. Complementing the integrated ETERNUS DX hardware storage management the ETERNUS SF storage management software is used to support overall daily operations within the entire storage infrastructure. ETERNUS DX’ embedded management, together with ETERNUS SF, serve as the overarching basis for Fujitsu’s highly efficient Flexible Data Management. It offers the same usability for all operational workflows throughout the ETERNUS DX series, from entry-level systems up to the high-end models. Therefore, acquired management skills can be leveraged over sites and over time. A high degree of automation and an easy to learn, easy to handle graphical user interface reduces significantly administrator’s training efforts with regards to cost and time. The customizable dashboard screen further eases all management tasks for the daily work. Storage resource optimization including implementation of policies for enhancing storage integration and operation, error discovery, health monitoring, capacity management, provisioning, local and remote replication and disaster recovery arepresented with a consistent user friendly look and feel.In addition to the cost savings given by the ergonomic and unified storage managementETERNUS SF also enables to eliminate unnecessarymaintenance cost as even complex storage management operations can be executed without high-level skills or expensive vendor’s intervention.A flexible and transparent license model guarantees that customers pay only needed functionalities and such can grow with rising requirements at foreseeable cost.ETERNUS SF Express is the management console for ETERNUS DX entry systems. ETERNUS DX60 S3/S4, DX100 S3/S4, DX200 S3/S4 disk storage systems and ETERNUS AF250 all-flash array are shipped with a free-of-charge ETERNUS SF Express license. The Express software offers basic management features, as well as simple, wizard basedconfiguration and can monitor multiple ETERNUS DX systems with one centralized console. For advanced features ETERNUS SF Express can be easily upgraded to ETERNUS SF Storage Cruiser.Features & BenefitsLicenses and functions overviewETERNUS SF Web GUIThe standard browser based graphical user interface provides an intuitive single console for the entire ETERNUS DX family and enables administrators to implement storage environments with ease and without high-level skills. A customizable dashboard facilitates real-time and comprehensive information regarding the current system state. ETERNUS SF Express LicenseFree-of-charge license for the ETERNUS DX entry systems that offers restricted functions for configuration, management and monitoring as well as basic snapshot capabilitiesETERNUS SF Storage Cruiser (SC) LicensesETERNUS SF SC Basic License: Offers functions to monitor and administrate multiple ETERNUS DX systems including unified (block and file) mangement, storage system configuration, thin provisioning, health and status overview, performance monitoring, Eco Mode settings, power consumption and temperature monitoring.ETERNUS SF SC Standard License: Enhanced license offering in addition to the basic license health, status and end-to-end relationship overview for 3rd party storage, switches, servers and VM’s, SAN managementwith correlation and map view and a reporting function. Mandatory prerequisite for the Optimization, QoS and Storage Cluster licenses.ETERNUS SF SC Optimization License: Enables automated tiering by setting policies to automatically place data on the right media at the right time, achieving the best balance between maximizing performance and minimizing cost(available for ETERNUS DX S3/DX S4 series except DX60 S3/S4, DX80 S2, DX90 S2, DX400 S2 series, DX8700 S2 and ETERNUS AF series).ETERNUS SF SC QoS Management License: Enables the consolidationof multiple tiers of applications in single storage systems. The ETERNUS SF QoS automation feature enhances the array-based ETERNUS DX QoS feature and automates the process by dynamically maintaining, controlling and balancing the response times of the application-specific volumes(available for ETERNUS DX100 S3/S4, DX200 S3/S4, DX500 S3, DX600 S3, DX8700 S3, DX8900 S3 and ETERNUS AF series).ETERNUS SF SC Storage Cluster License: Transparent failover feature which ensures business continuity in case of planned or unplanned outage of a complete array(available for DX100 S3/S4, DX200 S3/S4, DX500 S3, DX600 S3, DX8700 S3, DX8900 S3, DX200F and ETERNUS AF series).ETERNUS SF AdvancedCopy Manager (ACM) LicensesETERNUS SF ACM Local Copy License: Offers a comprehensive set of array-based snapshot, cloning and mirroring capabilities including wizard- assisted backup for Exchange and SQL Servers. Mandatory prerequisite for the Exchange Server and SQL Server licensesETERNUS SF ACM Remote Copy License: Enables synchronous or asynchronous remote mirroring between arrays. Mandatory prerequisite for the Storage Cluster license(not available for ETERNUS DX60/DX60 S2/DX60 S3/DX60 S4/DX80/DX80 S2).ETERNUS SF ACM for Exchange Server License: Restore wizard for Exchange ServerETERNUS SF ACM for SQL Server License: Restore wizard for SQL Server Feature PacksETERNUS SF Replication Bundle: includes SC Standard License, ACM Local Copy, ACM Remote Copy, ACM for Exchange, ACM for SQL Server licenses (available for ETERNUS DX S3 / DX S4 series, for DX60 S3/S4 wihout ACM Remote Copy).ETERNUS SF Replication Bundle with Tiering: includes Replication Bundle and SC Optimization Option licenses(available for ETERNUS DX S3 / DX S4 series except DX60 S3/S4).ETERNUS SF Tiering Bundle: includes SC Standard and SC Optimization Option licenses(available for ETERNUS DX100 S3/S4, DX200 S3/S4, DX500 S3, DX600 S3). ETERNUS SF Business Continuity Bundle: includes SC Standard, ACM Remote Copy and Storage Cluster Option licenses.(available for ETERNUS DX100 S3/S4, DX200 S3/S4, DX500 S3, DX600 S3 ). All-in FlashPack: includes SC Standard, ACM Local & Remote Copy and SC Quality of Service Management Option .(included in ETERNUS AF series).More details for all features can be found on:/global/products/computing/storage/disk/eternus-dx/ feature/Technical detailsETERNUS SF Whitepapers and Details for FeaturesETERNUS SF Technical Whitepaper /global/products/computing/storage/software/eternus-sf/index.html Storage Cluster /global/products/computing/storage/disk/eternus-dx/storage-cluster/ VMware VVOL /global/products/computing/storage/disk/eternus-dx/eternusdx-vvol/ ETERNUS SF Storage Cruiser- Supported DevicesDisk Storage Systems ETERNUS DX60 S4, DX100 S4, DX200 S4ETERNUS DX60 S3, DX100 S3, DX200 S3, DX500 S3, DX600 S3ETERNUS DX8700 S3, DX8900 S3ETERNUS DX60/DX60 S2, DX80 S2, DX90 S2ETERNUS DX410/DX410 S2, DX440/DX440 S2ETERNUS DX8400, DX8700/DX8700 S2NetApp FAS seriesTintri VMstore series (can be monitored only by the management server for Windows)All Flash Arrays ETERNUS AF250, AF650ETERNUS DX200FTape Libraries ETERNUS LT20/LT20 S2, LT40/LT40 S2, LT60 S2ETERNUS LT200, LT210, LT220, LT230, LT250, LT270, LT270 S2, LT260Data Protection Appliances ETERNUS CS800, CS800 S2, CS800 S3, CS800 S4, CS800 S5ETERNUS CS2000Fibre Channel Switches Brocade 12000, 24000, 48000Brocade 8000, 7800, 7500, 6730, 6710, 6510, 6505, 5000, 5100, 5300, 5450Brocade 4016, 4016 4D, 4100, 4900Brocade 3250, 3850, 3014, 3200, 3800, 3900Brocade G620Brocade 200E, 300Brocade DCX 8510-4/8, DCX, DCX-S4Brocade X6-4/8Brocade AP7420PRIMERGY Fibre Channel Switch BladePRIMERGY BX600 Fibre Channel Switch BladePRIMERGY Fibre Channel Switch BladeS26361-F3144-E1/L1, S26361-F3144-E2/L2, S26361-F3144-E4S26361-F3144-E6, S26361-F3144-E14, S26361-F3144-E16S26361-K1305-V14, S26361-K1305-V26, S26361-K1305-V126ETERNUS SF AdvancedCopy Manager - Supported DevicesDisk Storage Systems ETERNUS DX60 S4, DX100 S4, DX200 S4ETERNUS DX60 S3, DX100 S3, DX200 S3, DX500 S3, DX600 S3ETERNUS DX8700 S3, DX8900 S3ETERNUS DX60/DX60 S2, DX80 S2, DX90 S2ETERNUS DX410/DX410 S2, DX440/DX440 S2ETERNUS DX8400, DX8700/DX8700 S2All Flash Arrays ETERNUS AF250, AF650ETERNUS DX200FETERNUS SF Express- Supported DevicesHybrid Storage Systems/Disk Storage Systems ETERNUS DX60 S4, DX100 S4, DX200 S4 ETERNUS DX60 S3, DX100 S3, DX200 S3 ETERNUS DX60/DX60 S2, DX80 S2, DX90 S2All Flash Arrays ETERNUS AF250ETERNUS DX200FInstallation specificationManager Platforms Microsoft Windows Server 2016Microsoft Windows Server 2012, 2012 R2Microsoft Windows Server 2008, 2008 R2Solaris 11 (11/11 or later), Solaris 10 (except ETERNUS SF Express)Red Hat Enterprise Linux 7Red Hat Enterprise Linux 6Red Hat Enterprise Linux 5Oracle Linux 6VMware® vSphere 6.0, 6.5VMware® vSphere 5.0, 5.1, 5.5Microsoft Windows Server 2016 Hyper-VMicrosoft Windows Server 2012 Hyper-V, 2012 R2 Hyper-VMicrosoft Windows Server 2008 Hyper-V, 2008 R2 Hyper-VHyper-V 2.0Agent Platforms Microsoft Windows Server 2016Microsoft Windows Server 2012, 2012 R2Microsoft Windows Server 2008, 2008 R2Microsoft Windows Server 2003, 2003 R2Solaris 11 (11/11 or later), Solaris 10Red Hat Enterprise Linux 7Red Hat Enterprise Linux 6Red Hat Enterprise Linux 5Red Hat Enterprise Linux AS v.4Red Hat Enterprise Linux ES v.4Oracle Linux 6SUSE Linux Enterprise Server 12HP-UX 11i v3, HP-UX 11i v3 (IPF)AIX 7.1/6.1VMware® vSphere 6.0, 6.5VMware® vSphere 5.0, 5.1, 5.5Microsoft Windows Server 2016 Hyper-VMicrosoft Windows Server 2012 Hyper-V, 2012 R2 Hyper-VMicrosoft Windows Server 2008 Hyper-V, 2008 R2 Hyper-VHyper-V 2.0KVM on RHEL 7KVM on RHEL 6Client - Web Browser Internet Explorer 9, 10, 11Firefox ESR 17, 24, 31, 38, 45, 52Microsoft Edge 25Client - Tablet (Dashboard Screens)Safari 8, 9 (iOS)Chrome 47, 50 (Android)ContactFUJITSU LIMITEDWebsite: /eternus2021-07-30 WW-ENworldwide project for reducing burdens on the environment.Using our global know-how, we aim to contribute to the creation of a sustainable environment for future generations through IT.Please find further information at http://www./global/about/environmentdelivery subject to availability. Any liability that the data and illustrations are complete, actual or correct is excluded. Designations may be trademarks and/or copyrights of the respective owner, the use of which by third parties for their own purposes may infringe the rights of such owner.。
Hayward Flow Control 1-888- 429-4635HAYWARD SERIES BFA and BFAS BULKHEAD FITTINGINSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONSPLEASE READ THE FOLLOWING INFORMATION PRIOR TO INSTALLING AND USING ANY HAYWARD PRODUCT. FAILURE TO FOLLOW THESEINSTRUCTIONS MAY RESULT IN PRODUCT DAMAGE, PROPERTY DAMAGE, PERSONAL INJURY, OR EVEN DEATH.1. Hayward Flow Control (Hayward), a division of Hayward Industries, guarantees its products against defective material and workmanship only. Hayward assumesno responsibility for property damage or personal injury resulting from improper installation, misapplication, or abuse of any product.2. Hayward assumes no responsibility for property damage or personal injury resulting from chemical incompatibility between its products and the process fluids towhich they are exposed. Determining whether a particular PVC, CPVC, or PP product is suitable for an application is the responsibility of the user. Chemical compatibility charts provided in Hayward literature are based on ambient temperatures of 70°F and are for reference only. 3. Hayward products are designed for use with non-compressible liquids.4. The maximum recommended fluid velocity through bulkhead fittings is eight feet per second (8 ft/s). Higher fluid velocity can result in damage due to the water hammer effect.5. Piping systems must be designed and supported to prevent excess mechanical loading on Hayward products due to system misalignment, weight, shock, vibration, and the effects of thermal expansion and contraction.6. The effect of temperature on plastic piping systems must be considered when the systems are initially designed. The pressure rating of plastic systems must be reduced with increasing temperature. Maximum operating pressure is dependent upon material selection as well as operating temperature. Before installing any Hayward product, consult Hayward product literature for pressure vs. temperature curves to determine any operating pressure or temperature limitations.7.PVC and CPVC plastic products become brittle below 40°F. Use caution in their installation and operation below this temperature.Due to differential thermal expansion rates between metal and plastic, transmittal of pipe vibration and pipe loading forces, DIRECT INSTALLATION OF HAYWARD FLOW CONTROL PRODUCTS INTO METAL PIPING SYSTEMS IS NOT RECOMMENDED . Wherever installation of Hayward product into metal piping systems is necessary, it is recommended that at least 10 pipe diameters in length of plastic pipe be installed upstream and downstream of the product to compensate for the factors mentioned above. 8.Published operating requirements are based on testing of new products using clean water at 70°F. Performance is affected by many factors including fluid chemistry, viscosity, specific gravity, flow rate, and temperature. These should be considered when sizing Hayward products. 9. Systems should always be depressurized and drained prior to installing or maintaining any Hayward product.10. Always follow your site and/or company procedures for any safety training and/or site specific precautions or warnings in addition to those in this document.DIMENSIONAL CONSIDERATIONS:The following table contains recommended values. Values are in inches. “SF”= Standard Flange “LF”= Large FlangeInside of TankOutside of TankHayward Flow Control 1-888- 429-4635INSTALLATION:The bulkhead fitting should be installed with the body and the gasket on the inside of the tank. The “flange” portion of the nut is installed against the tank wall. The nut/body thread is a left-handed thread. Follow the tightening direction arrow on the nut. Tighten the nut while holding the body. The nut can be tightened from the outside of the tank by holding the flats on the body end while turning the nut. The nut should be hand tight plus 1/4 to 1/3 of a turn to insure a gasket seal. Once adjoining piping is connected and the system filled the fitting should be visually checked to insure that the gasket is sealing and there are no leaks at the pipe connection. If leaks are observed, drain the system, tighten the connections, and repeat the filling and checking process.Wrap male threads of pipe end with PTFE tape. Proper application of PTFE tape will provide a sufficient seal for PVC, PP, GFPP, and CPVC threaded joints.bulkhead fitting only to the point required to form a seal between the bulkhead fitting and the pipe thread; 1/2 turn past hand tight is typically sufficient to form a seal. (Caution: Tightening beyond this point may introduce excessive stress that could cause failure of the bulkhead or the threaded end of the pipe.) Once the system is filled, visually check for leaks. If leaks are observed, drain the system, tighten the connections, and repeat the filling and checking process. SOCKET CONNECTION (PVC and CPVC only):Refer to solvent-cement manufacturer’s instructions and cure times.MAINTENANCE: The Hayward Series BFA and BFAS Bulkhead Fitting are not intended to be repaired. Fittings that are damaged during installation or operation should be replaced. OPERATION:The following ratings must be observed during Pressure rating of PVC, CPVC, PP, and GFPP Series BFA and BFAS at 70°F is 150 psi, non-shock. See Pressure vs. Temperature graph for pressure down rating due to temperature.Scan for an online copy of this document.。
仓库管理软件说明书一、系统特性:1、具备通用仓库进、销、存的数据输入、查询、打印、备份、还原、操作人员菜单权限设置等功能。
2、可以随时根据用户需要设置材料和往来代码类别分级情况(系统默认分6级,特殊用户需要可分任意级别)。
3、可以根据用户需要增加或删除各种单据,并设置每种单据的格式。
4、可以根据用户需要增加或删除各种表格中的各项目(各栏、字段)。
5、各种表格可以根据不同条件设置运算公式。
6、材料出入库单价可以用“计算单价('方法名称')”函数按“先进先出、后进先出、加权平均”三种方法计价。
6、输入、查询不同单据、表格可以根据“项目过虑器”设置各种表格格式。
7、具体强大的代码查找功能,当启用“输入任意字符查找代码”功能后,只需输入“名称规格”中任意字符可找到相关数据。
8、具备强大的数据汇总功能,可以根据用户不同条件需要汇总或分级汇总各种数据并打印。
二、系统安装与进入1.本系统可安装于Win9X,Win2000,WinXp系统。
2.运行Setup.exe文件可进行安装,接着按系统提示选择即可。
3.安装完成后,回到桌面,双击“仓库管理软件”图标即可进入系统。
三、系统功能㈠、系统维护●系统初始化Ⅰ、系统初始设置1、远程用户数量:例如:输入“2”,表示系统充许两个远程用户传送数据,第一个代码为“01”,第二个代码为“02”,以此类推。
输“0”表示不充许远程传送数据。
此数值用户可以随时修改。
2、库存数量提示:选择此项,当材料库存数量大于或小于设置的“库存上限”或“库存下限”时,进入系统时提示。
3、输入任意字符查询代码:当选择此选项时,可以输入材料属性代替代码输入,如:输入“30*30”,则所有包含“30*30”的代码都显示出来,方便用户查找。
启用此功能后查找速度会有所减慢。
4、材料、往来代码分级:系统代码最小可以分2级,最大分6级,第一级长度为不能小于2位,其他级别长度用户定义。
用户需根据自已的需要设置好分级。
产品手册WBOX-516X,无风扇工业计算机版本:V1.01 / 41认可声明AMI 为Award Software International, Inc. 的商标。
Intel 和Atom 为Intel Corporation 的商标。
IBM、PC/AT、PS/2 和VGA 为International Business Machines Corporation的标。
Intel 和Atom 为Intel Corporation 的商标。
Microsoft Windows 为Microsoft Corp. 的注册商标。
RTL 为Realtek Semiconductor Co., Ltd. 的商标。
所有其它产品名称和商标均为其所有者的财产。
本手册适用于WBOX-516x系列.符合性声明这些限制旨在为商业环境下的系统操作提供合理保护,使其免受有害干扰。
本设备会产生、使用和发射无线电频率能量。
如果没有按照手册说明正确安装和使用,可能对无线电通讯造成有害干扰。
但即使按照手册说明进行安装和使用,也并不能保证不会产生干扰。
若本设备会对无线电或电视信号接收产生有害干扰,用户可通过开、关设备进行确认。
当本设备产生有害干扰时,用户可采取下面的措施来解决干扰问题:●1、调整接收天线的方向或位置●2、增大本设备与接收器之间的距离●3、将本设备的电源接头插在与接收器使用不同电路的电源插座●4、若需技术支持,请咨询经销商或经验丰富的无线电/电视技术人员警告!权利可能会被取消。
包装清单在您打开包装时,请确认包装中附有以下各项:●–WBOX-516x 1pcs附件盒,装有以下各项:●- 电源端子1pcs●- 国标电源线1.8米(可选)1pcs●- 电源适配器(可选)1pcs如果其中任何一项缺失或者破损,请立即联系您的销售商或销售代表。
2 / 41选购信息技术支持与服务用户若需技术支持,请与当地分销商、销售代表客服中心联系。
进行技术咨询前,用户须将下面各项产品信息收集完整:–产品名称及序列号–外围附加设备的描述–用户软件的描述(操作系统、版本、应用软件等)–产品所出现问题的完整描述–每条错误信息的完整内容警告! 1. 输入电压为DC 12-24V电源(电源功率90W或以上)2. 包装:需谨慎,请以双手托住设备。
USR-C215软件设计手册文件版本:V1.8.0产品特点:●支持********GHz802.11b/g/n无线标准●支持WEP/WPA/WPA2安全模式●支持AP、STA、AP+STA工作模式●完全集成的串口转无线TCP/UDP传输功能,多个串口速率选择●局域网搜索和无线参数设置功能●支持TCP/UDP Client注册包机制●支持Simple Config/Airkiss/usrlink快速联网配置●支持类RFC2217自动波特率适配功能●支持简单AT+指令集配置●Httpd Client功能● 3.3V单电源供电●可选择内置天线,外置天线(IPEX连接器)●超小尺寸:22.0mm x13.5mm x9.2mm,单排1x102mm插针封装目录USR-C215软件设计手册 (1)1.产品概述 (3)1.1.产品简介 (3)1.2.模块基本参数 (4)2.产品功能 (5)2.1.Wi-Fi无线组网方式 (5)2.1.1.模块作为STA方式 (6)2.1.2.模块作为AP方式 (7)2.1.3.模块作为AP+STA模式 (7)2.1.4.加密方式 (8)2.2.工作模式 (8)2.2.1.透明传输模式 (8)2.2.2.命令模式 (12)2.2.3.HTTPD Client模式 (12)2.3.串口参数 (18)2.3.1.串口参数简介 (18)2.3.2.类RFC2217自动波特率功能 (19)2.4.特色功能 (21)2.4.1.局域网搜索功能 (21)2.4.2.TCP/UDP Client注册机制、透传云 (23)2.4.3.快速联网协议(usrlink) (24)2.4.4.Simple Config/Airkiss智能配置 (27)2.4.5.心跳包机制 (27)2.4.6.自定义网页功能 (29)2.4.7.Wi-Fi连接异常处理 (31)3.设置方法 (33)3.1.Web页面设置 (33)3.1.1.打开管理网页 (33)3.1.2.WiFi参数设置 (34)3.1.3.透传参数设置 (35)3.1.4.附加功能设置 (35)3.1.5.系统管理 (36)3.1.6.固件升级页面 (37)3.1.7.关于有人页面 (37)3.1.8.备用升级页面 (38)3.2.AT指令配置 (38)3.2.1.AT指令概述 (39)3.2.2.AT指令集 (40)4.联系方式 (68)5.免责声明 (69)6.更新历史 (70)1.产品概述1.1.产品简介USR-C215硬件上集成了MAC、基频芯片、射频收发单元;内置低功耗运行机制,可以有效实现模块的低功耗运行;支持Wi-Fi协议以及TCP/IP协议,用户仅需简单配置,即可实现UART设备的联网功能。
韦氏盈创仓库管理系统V1.0用户手册厦门韦氏盈创科技有限公司-版权所有目录1引言 (3)1.1编写目的 (3)1.2参考资料 (3)1.3术语和缩略词 (3)2软件概述 (4)2.1软件功能 (4)2.2软件运行 (5)本系统运行在PC 及其兼容机上,使用WINDOWS 操作系统,在软件安装后,直接点击相应图标,就可以显示出软件的主菜单,进行需要的软件操作。
(5)2.3系统要求 (5)3系统使用 (5)3.1系统登录 (5)3.2人员信息维护 (6)3.2.1个人密码修改 (7)3.2.2权限设置 (7)3.2.3添加新成员 (8)3.2.4人员信息浏览 (9)3.3货品信息维护 (10)3.3.1货品信息查询 (10)3.3.2货品信息增加 (11)3.3.3货品信息删改 (11)3.4仓库信息维护 (12)3.4.1仓库信息浏览 (12)3.4.2仓库信息添加 (13)3.5存放规则维护 (13)3.5.1存放规则浏览 (14)3.5.2添加存放规则 (14)3.6货物进出记录 (15)3.6.1货物进出浏览 (15)3.6.2货物进出添加 (16)3.7库存信息 (16)3.8系统功能 (17)1引言1.1编写目的韦氏盈创仓库管理系统是一个公司工作中不可缺少的一部分,他对于公司的人员以及财务的管理者和被管理者都非常重要。
所以仓库管理系统应该为管理者和被管理者提供充足的信息和快捷的数据处理手段,但长期以来,人们使用传统的人工方式或性能较低的仓库管理系统来管理公司日常事务,操作流程比较繁琐,错误率比较高。
一个成功的管理系统应提供快速的信息检索功能,增加和修改功能。
1.2参考资料《软件需求规格说明书》《概要设计说明书》《详细设计说明书》1.3术语和缩略词A.I. 人工智能API (Application Programming Interface) 应用(程序)编程接口Software Quality Assurance软件质量保证UI Testing界面测试2软件概述2.1软件功能(1)进、出库管理。
8491/2" - 2" ELECTRICPVC HEATERFor additional copies at no chargeorder 999 6045.1CONTENTSWarranty (2)Specifications (2)Introduction (2)Bending Tips (2)Operation1. Set Up (3)2. Heating PVC (3)3. Bending PVC (3)Exploded View - No. 849 .........................................4-5 Parts List - No. 849 .. (6)Wiring Diagram (7)WARRANTYYour Greenlee No. 849 Electric PVC Bender is warranteed to be free from defects in material and workmanship. Terms of the warranty are enclosed with your bender along with the Warranty Certificate Card. I MPORTANT: This card must be completed and returned in order to put your warranty into immediate effect.SPECIFICATIONSModel No. 849 2" Electric PVC BenderPower: 120 Volts 20 amp AC, 60 cycle. 3-conduct or 14Gauge grounded cord with plug supplied with unit. Operating Temperature: 475° Maximum, thermostatcontrolled.Heating element will reach 1000° F (540° C). Controls: Single-pole power switch.Capacity: Up to 2" diameter PVC conduit. Heats 24" length for 90° elbows of standard radius.Heatlng Element: Calrod TypeDimensions: Depth-7", Length-28-1/4", Height-10-3/4" Weight: 17 lbs.INTRODUCTIONThe Greenlee No. 849 Electric PVC Bender is designed to provide a single operator with an effective and easily portable means for heating small diameter PVC conduit for bending. The only other materials required for making bends are as follows:1. Insulated Rubber or other Heavy Duty Gloves2. Pail of water3. Sponge or clean rag4. Scrap PVC for test run IMPORTANT BENDING TIPS1. U se this bender only in a well ventilated area. Do notoperate this unit near volatile or combustible materials. 2. W ear insulated gloves when operating this unit andalways use the plastic handles when moving or open -ing unit.3. A few practice bends using sections of scrap PVC arealways recommended so that operator becomes famil- iar with the operation of this unit.4. S ince a 10 to 15 minute warm-up period is requiredbefore bending can begin, operator should set up unit and switch on the power as soon as he arrives at the job site. During warm-up, operator can assemble his mate- r ials, plan his bends, and mark the bend areas on the PVC conduit.5. T o help prevent kinks or wrinkles when making 90degree bends in 2" PVC duct, use 2 Greenlee No.30976 PVC Plugs to trap the air in the conduct and helpkeep the PVC from flattening or kinking.OPERATION1. S et Up - Connect unit to power source (120 Volts, AC,60 cycle). Turn switch to on position (built-in pilot lightindicates when unit is operating). After a warm-up period of 10 to 15 minutes, the heating and bending of PVC conduit can begin.2. H eating PVC - For best results, test for the best heatingtime using a few pieces of scrap PVC. With all materials at hand lower the door of the unit until it is fully open. Lay first section of PVC between the pairs of guide rollers on either end of the unit as shown in Fig. 3. The section of PVC you wish to bend must be centered within the unit.Keep door of unit closed during the heating process.To obtain even heating of the PVC, conduit must be constantly rotated by hand, as shown in Fig. 4. The PVC should become pliable enough for bending after about one minute. Heating time may vary due to differ-ences in size and thickness of the PVC. An automatic thermostat regulates temperature and prevents over-heating of the unit.3. Bending PVC - When PVC becomes pliable, lift open Keep a close watch on the PVC and keep close track of the time to prevent scorching of the conduit.door and remove from unit, laying the conduit on a flat, clean surface. Bend can now be shaped by hand. To set the bend, cool the PVC by using a rag or spongesoaked with cool water, as shown in Fig. 5.Exploded View No. 849 2" Electric PVC BenderParts ListNo. 849 2" Electric PVC BenderKEY CONTROL NO.DESCRIPTIONQTY.1502 7773.1Cover Unit (Key No's. 2, 3, 39, & 4 of Key 41)12502 7766.9Reflector, Cover13905 2976.6Handle, Davies #692 Heat Resistant Black Plastic14502 7775.8Housing Unit (Key No's. 5 thru 22, 40, and 4 of Key 41, 42 & 43)15502 7761.8Insulation, Top 16502 7762.6Insulation, Back 27502 7764.2Cover, Switch Box 18502 7771.5Reflector, Housing 19502 7811.8Heater110502 8285.9Reflector, Top Housing111905 0372.4Nut, 1/4-20 Hex Jam (for box mounting)112905 0520.4S crew, 1/4-20 NC x 3/4 SAE Grade 5 Hex Head Cap (for heater mounting)113905 0717.7S crew, #10-24 x 1/2 Round Head Machine (for cover plate and box mounting)614905 0750.9W asher, #10 Shakeproof Internal Teeth, 3/8 O.D. x .021 Lock616905 1593.5Nut, 1/4-20 Zinc Plated Hex (for heater mounting)117905 1647.8Washer, 1/4 Shakeproof Internal Teeth Zinc Plated Lock 118905 2434.9Nut, #8-32 Zinc Plated Hex 119905 2973.1Spacer, Micro Plastics #166 Nylon (for box mounting)220918 6008.3Snap-Bushing, Heyco #SB-500-6 Nylon 121918 6019.9Thermostat, Bimet #HF-79-114, 475° Range 122502 7763.4Box Unit, Control (Key No's. 23 thru 25)123502 7806.1Cord Unit 124918 6009.1Bushing, Heyco #SR-7W-2 Nylon Strain-Relief 125918 6015.6Switch, Carling #RGSCC711RBBA Double Pole 126905 0877.7Screw, 1/4-20 NC x 1-1/4 SAE Grade 5 Hex Head Cap 427905 2971.5W heel, McMaster-Carr #9960-Y-14 1/78 Dia Steel Centered Skate428905 2339.3Washer, 5/16 ID x 3/4 OD x 1/16, Zinc Plated 429905 1593.5Nut, 1/4-20 NC Zinc Plated Hex 430905 2969.3Screw, #10-24 x 2 Round Head Machine 231905 2970.7H andle, Daview #4560 Heat-Resistant Black Plastic WARNING: DUE TO HIGH TEMPERATURES USE ONLYWIRE UNITS BELOW OR EQUIVALENT. (SEE WIRING DIAGRAM.)132*502 7751.0Wire Unit, 7" (Not Shown)133*502 7752.9Wire Unit, 10-1/2" (Not Shown)134*502 7753.7Wire Unit, 12" (Not Shown)1502 8286.7Insulation, Control Box (Not Shown)235*905 2428.4S crew, #8-32 x 1/4 Parker-Kalen Type-F Zinc-Plated Slotted Round Head Tapping (Not Shown)1918 6008.3S nap-Bushing, Heyco #SB-500-6 Nylon (Not Shown; for 3 wire units in housing)236503 6835.4Upper Insulation 137918 6474.7Pilot Light 138*503 7278.5Wire Unit, Pilot Light 239502 8002.3Product Decal, 849140503 7201.7Warning Decal, Hot 141905 3001.2Pop Rivet 842503 0392.1Decal, Damp Warming 143503 6096.5Decal, Electrical Shock1* Not shown on exploded view. See wiring Diagram, page 7.Greenlee Tools, Inc.4455 Boeing Drive, Rockford, IL 61109-2988 USA800/435-0786, in Illinois call 815/397-7070Fax: 815/397-1865Service: 800/435-2932, Canada: 800/233-5924Printed in U.S.A.。
Sun StorageT ek™ NAS 作業系統軟體版本說明4.21 版Sun Microsystems, Inc.文件號碼 819-7732-122007 年 6 月,修訂版 A請將您對本文件的意見提交至:/hwdocs/feedback請回收Copyright 2007 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, U.S.A. 版權所有。
Sun Microsystems, Inc. 對於本文件所述技術擁有智慧財產權。
這些智慧財產權包含 /patents 上所列的一項或多項美國專利,以及在美國與其他國家/地區擁有的一項或多項其他專利或申請中專利,但並不以此為限。
本文件及相關產品在限制其使用、複製、發行及反編譯的授權下發行。
未經 Sun 及其授權人 (如果有) 事先的書面許可,不得使用任何方法、任何形式來複製本產品或文件的任何部分。
協力廠商軟體,包含字型技術,其版權歸 Sun 供應商所有,經授權後使用。
本產品中的某些部分可能源自加州大學授權的 Berkeley BSD 系統的開發成果。
UNIX 是在美國及其他國家/地區的註冊商標,已獲得 X/Open Company, Ltd. 專屬授權。
Sun 、Sun Microsystems 、Sun 標誌、Java 、AnswerBook2、 、Sun StorEdge 、Sun StorageTek 與 Solaris 是 Sun Microsystems, Inc.在美國及其他國家/地區的商標或註冊商標。
所有 SPARC 商標都是 SPARC International, Inc. 在美國及其他國家/地區的商標或註冊商標,經授權後使用。
凡具有 SPARC 商標的產品都是採用 Sun Microsystems, Inc. 所開發的架構。
OPEN LOOK 與 Sun™ Graphical User Interface (Sun 圖形化使用者介面) 都是由 Sun Microsystems, Inc. 為其使用者與授權者所開發的技術。