UNI500说明书N
- 格式:doc
- 大小:324.00 KB
- 文档页数:15
用户手册嗨酷乐Inpulse 500打碟机1.概览2.包装清单-Hercules DJControl Inpulse 500 (嗨酷乐Inpulse 500打碟机) -USB 电缆-安装和快速入门指南-保修信息3.打碟机规格3.1.机械规格-尺寸:54 x 29.6 x 5.6 cm(宽 x 深 x 高,收缩支腿时)——54 x 29.6 x 9.1 cm(宽 x 深 x 高,展开支腿时)-重量:3.2 kg3.2.技术规格USB MIDI 打碟机,配备:双转盘- 2 x 4 个走带按钮:SHIFT / PLAY / CUE / SYNC- 2 组打击垫,每组 8 个 = 共 16 个;2 组打击垫模式按钮,每组 4 个 = 共 8 个(HOT CUE、LOOP、SLICER、SAMPLER、MODE 5、MODE 6、MODE 7、MODE 8)- 2 x 3 个 LOOP 控件:每个转盘上设有 LOOP IN 和 LOOP OUT 按钮;每个转盘上带有 1 个内置下压按钮的 LOOP SIZE 旋转编码器;Reloop(退出循环)- 2 x 3 个模式按钮:Vinyl / Slip / Quantize- 2 个带电容式触摸检测功能的缓动盘- 2 个音调推子- 2 x 2 个灯光指引(Tempo 和 Phase),用于辅助对拍混音器-导航控件:o 1 个内置下压按钮的旋转编码器,用于导航音乐库;1 个背光圆环,用于显示主曲目的活力级别o 2 个用于将曲目加载到转盘上(虚拟转盘)的按钮o 1 个 Assistant 按钮,用于帮助您选择待播放的曲目o 1 个 Beatmatch Guide 按钮-转盘混音区控件:o 2 个三波段均衡器,带有HIGH(高音)、MID(中音)和LOW(低音)频率旋钮o 2 个转盘增益旋钮o 2 个转盘音量推子o 2 个转盘音量计,每个音量计支持 9 级音量o 2 个用于启用/禁用耳机监听转盘的按钮和1 个用于启用/禁用耳机监听Master 输出的按钮o 1 个交叉推子,另加1 个开关,用于从3 个不同的交叉推子曲线中做出选择-Filter/Fx 控件:o 2 个滤波器/音效旋钮o 4 个音效按钮,允许通过滤波器/音效旋钮来控制音效-混音输入和输出控件(通过硬件):o麦克风输入:1 个麦克风音量旋钮;2 个麦克风均衡器旋钮,用于调节HIGH(高音)和LOW(低音)频率;1 个双色音量计(关= 无音频信号 / 绿色 = 音频信号 / 红色 = 音频信号饱和度)(硬件调节)o Aux 输入:1 个辅助输入音量旋钮和 1 个辅助滤波器旋钮(硬件调节);1 个双色音量计(关 = 无音频信号 / 绿色 = 音频信号 / 红色 = 音频信号饱和度)(硬件调节)o耳机输出:1 个耳机音量旋钮;1 个 Cue/Master 旋钮,用于选择在耳机上听到的声音(硬件调节)o Master 输出:1 个主音量旋钮;1 个 5 级主音量计(硬件调节)内置多声道音频接口音频解析度:24 位采样频率 = 44.1 kHz输出:-音箱输出 (= 1-2):2 x RCA 输出 + 2 x 6.35 mm 插孔输出-耳机输出 (= 3-4):3.5 mm 立体声迷你插孔 + 6.35 mm 立体声插孔输出输入:-AUX 辅助输入 (= 1-2):2 x RCA 输入 + 1 x 3.5 mm 立体声迷你插孔输入-MIC 麦克风输入:6.35 mm 平衡式插孔输入4.安装4.1.连接连接到计算机(通过 USB)注意:每次将打碟机连接到计算机时都会启动LED 指示灯亮起序列(称为Vegas Mode),显示 LED 所处的位置。
241LS-400FIBERSENSORSLASERSENSORSHUMAN MACHINEINTERFACESENERGY CONSUMPTIONVISUALIZATIONCOMPONENTSFA COMPONENTSMACHINE VISIONSYSTEMSUV CURINGSYSTEMSFeaturing stainless steel (SUS) enclosure that won’tbreak when bumped during installation or maintenance.(In STD amplifier response time mode)Unit: mm in Stainless steel (SUS) body 1 m 3.281 ft sensing rangeOne-point M6 installationFeaturing waterproof IP67 to allow use in the presenceof large amounts of water or dust.Two-point installationThe thru-beam type LS-H102 features the same formfactor as the EX-L200 series ultra-compact laser sensorwith built-in amplifier, and it can be used as an EX-L200series with a digital indicator. It also delivers the samebend quality as theEX-L200 series.The LS-H101 features an easy-to-install design.M6Body: Stainless steel(SUS)Operationindicator(receiver only)Actual size1 m 3.281 ft sensing range(In STD amplifier response time mode)The LS-H102 delivers sufficient sensing range for use with450 mm 17.717 in wafers.Check the optimal receiving location at a glance whilewatching the red spot on the beam axis adjustmentscreen.Simple positioningInstallation pitch13 mm 0.512 inEX-L211 / EX-L212LS-H102Same installation pitchas the EX-L200 series Waterproof IP67SEN TRONIC242LS-400FIBER SENSORS PHOTOELECTRIC SENSORS MICROPHOTOELECTRIC SENSORS AREASENSORS LIGHT CURTAINS /SAFETYCOMPONENTS PRESSURE / FLOWSENSORS INDUCTIVE PROXIMITY PLCHUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMSUV CURING SYSTEMSIndustry’s smallest* + Thinnest profile* S mallest amplifier-separated type laser sensor head as of September 2013 based on research conducted by our companyLS-H201Coaxial designSmall, long-range spotEasy-to-see operation indicatorBy using a laser with high linearity in a coaxial design, the LS-H201 is able to deliver stable sensing in confined spaces as well as simple installation.The LS-H201 produces a spot with a diameter of 2 mm 0.079 in at a sensing range of up to 300 mm 11.811 in (in STD amplifier response time mode).The LS-H201’s operation indicator is visible from all directions.Featuring a 60% smaller design (by volume) than previous coaxial reflective models, our smallest unit is smaller in every dimension at just W8 × H23 × D18 mm W0.315 × H0.906 × D0.709 in (excluding indicators).0.315 in23mm ø2 mm ø0.079 in300 mm 11.811 inGasketLS-400FIBER SENSORS PHOTOELECTRICSENSORS MICROPHOTOELECTRICSENSORS AREA SENSORS LIGHT CURTAINS /SAFETY COMPONENTS PRESSURE /FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORSSENSOR OPTIONS SIMPLE WIRE-SAVINGUNITS WIRE-SAVINGSYSTEMS MEASUREMENTSENSORS STATIC ELECTRICITYPREVENTION DEVICES LASER MARKERSPLCHUMAN MACHINEINTERFACES ENERGY CONSUMPTIONVISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISIONSYSTEMS UV CURING SYSTEMSFX-500 series fiber sensor LS-500 series laser sensor0.315 in4 mm 0.157 inAmong industry’s fastest response times* 60 μs* A mplifier-separated type laser sensor amplifiers as ofSeptember 2013 based on research conducted by our company* S mallest amplifier-separated type laser sensor head as ofSeptember 2013 based on research conducted by our companyLS-501□Industry’s smallest* and thinnest designHorizontal symmetryFeaturing a simple system design process thanks to a light source that is placed in the center of the sensor head and a coaxial design.Engineered for maximum compatibility with fiber sensors in every aspect of its design, from form factor to operability, the LS-500 series delivers an environment that makes it easy to choose a laser sensor.The LS-H901 is even thinner than previous models, measuring just W8 × H23 (excluding indicators) × D18 mm W0.315 × H0.906 × D0.709 in .Maximum compatibility with fiber sensorsDetection of beam axis misalignmentDual outputs (self-diagnosis output)Stable sensing over the long term Logic operationsData bankThe LS-500 series features the same operation, menu displays, and form factor as the FX-500 series for increased compatibility with fiber sensors.The LS-500 series can detect any reduction in incident light intensity, for example due to the accumulation of dirt such as dust, and issue an alarm. Sensing output 2 can be set as self-diagnosis output. When you teach the threshold for sensing output 1, sensing output 2 is set accordingly, allowing you to shift the threshold by a previously set margin.The LS-500’s threshold-tracking function helpsmaintain stable sensing over the long term and reduce maintenance man-hours. The incident light intensity can be checked and the threshold automatically reset at a user-selected interval to track changes in light intensity due to environmental changes (such as dust, etc.) over extended periods of time. The LS-500’s ability to perform three logic operations (AND, OR, and XOR) on a standalone basis eliminates the need for a dedicated controller, cuts down onwiring, and lowers costs. This functionality can also be combined with the FX-500 series.Eight sets of amplifier settings can be stored in the unit’s built-in memory. The ability to save and load settings reduces workload when changing the setup in a multi-model production environment.LS-400PHOTO-ELECTRIC SENSORS MICRO PHOTO-ELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS /SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASURE-MENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTSFACOMPONENTS MACHINE VISION SYSTEMSUVCURING SYSTEMSORDER GUIDE056 222 38 18SEN TRONIC AG245Digital Laser Sensor LS-500SERIESLS-400FIBERSENSORSPHOTO-ELECTRICSENSORSMICROPHOTO-ELECTRICSENSORSAREASENSORSLIGHTCURTAINS /SAFETYCOMPONENTSPRESSURE /FLOWSENSORSINDUCTIVEPROXIMITYSENSORSPARTICULARUSESENSORSSENSOROPTIONSSIMPLEWIRE-SAVINGUNITSWIRE-SAVINGSYSTEMSMEASURE-MENTSENSORSSTATICELECTRICITYPREVENTIONDEVICESLASERMARKERSPLCHUMANMACHINEINTERFACESENERGYCONSUMPTIONVISUALIZATIONCOMPONENTSFACOMPONENTSMACHINEVISIONSYSTEMSUVCURINGSYSTEMSSensor head mounting bracketMaterial: Stainless steel (SUS304)Two M3 (length 14 mm 0.551 in)screws with washers [stainlesssteel (SUS304)] are attached.• MS-EXL2-5Fine-Rotatethrough360°Reflector• RF-310• RF-31Reflective tape9.2 mmAccessoriesMS-LS-1 (Sensor head mounting bracket)For LS-H201□ / LS-H901□mountingBack angledmountingRF-330 (Reflector)MS-EXL2-2 (Mounting plate for thru-beam type)Mounting plateMaterial: Stainless steel (SUS304)Two M2 (length 12 mm 0.472 in) screws with washers[stainless steel (SUS)] are attached.Material: Stainless steel (SUS)Material: Die-cast zinc alloyTwo M3 (length 14 mm 0.551 in) screws withwashers [stainless steel (SUS)], one M3 (length 10mm 0.394 in) hexagon-socket-head bolt [stainlesssteel (SUS)], and one M3 hexagon nut [stainlesssteel (SUS)] are attached.0.551 in) screws withwashers [stainless steel (SUS)] are attached.056 222 38 18*********************SEN TRONICAG246Digital Laser SensorLS-500SERIESLS-400FIBER SENSORS PHOTO-ELECTRIC SENSORS MICRO PHOTO-ELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS /SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITSWIRE-SAVING SYSTEMS MEASURE-MENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FACOMPONENTSMACHINE VISION SYSTEMS UVCURING SYSTEMSNotes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F . 2) When using the thru-beam type LS-H101□ or LS-H102□, do not set the receiving light sensitivity (gctL) of the applicable LS-500 series amplifier to level2 or less. This is because there is a possibility of sensing becoming unstable.3) The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm 3.937 × 3.937 in ) as the object. 4) The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible settingrange for the reflector. The sensor can detect an object less than 0.01 m 0.033 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower thesensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicable LS-500 series amplifiers, leave an adequate safety margin when setting the threshold.5) Make sure to confirm detection with an actual sensor before use. 6) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH (Center for Devices andRadiological Health) under the FDA (Food and Drug Administration). For details, refer to the Laser Notice No. 50.7) Cable cannot be extended.056 222 38 18*********************SEN TRONIC AG247Digital Laser Sensor LS-500SERIESLS-400FIBERSENSORSPHOTO-ELECTRICSENSORSMICROPHOTO-ELECTRICSENSORSAREASENSORSLIGHTCURTAINS /SAFETYCOMPONENTSPRESSURE /FLOWSENSORSINDUCTIVEPROXIMITYSENSORSPARTICULARUSESENSORSSENSOROPTIONSSIMPLEWIRE-SAVINGUNITSWIRE-SAVINGSYSTEMSMEASURE-MENTSENSORSSTATICELECTRICITYPREVENTIONDEVICESLASERMARKERSPLCHUMANMACHINEINTERFACESENERGYCONSUMPTIONVISUALIZATIONCOMPONENTSFACOMPONENTSMACHINEVISIONSYSTEMSUVCURINGSYSTEMS2) 25 mA if 5 or more amplifier are connected in cascade (excluding cable extension).3) Number of units that can be mounted close together: 0 for H-SP; 2 for FAST; 4 for STD, LONG, U-LG, or HYPR4) Select either sensing output 2 or external input as the connector type.056 222 38 18*********************SEN TRONICAG248Digital Laser SensorLS-500SERIESLS-400FIBER SENSORS PHOTO-ELECTRIC SENSORSMICRO PHOTO-ELECTRIC SENSORS AREA SENSORSLIGHTCURTAINS /SAFETY COMPONENTSPRESSURE /FLOW SENSORS INDUCTIVE PROXIMITY SENSORSPARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASURE-MENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLCHUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FACOMPONENTSMACHINE VISION SYSTEMS UVCURING SYSTEMSSymbols ...D 1, D 2, D 3, D 4: Reverse supply polarity protection diodeZ D1, Z D2: Surge absorption zener diode Tr 1, Tr 2 : NPN output transistor%Notes: 1) The quick-connection sub cable does not have +V (brown) and 0 V (blue).The power is supplied from the connector of the main cable.2) Wiring when sensing output 2 is selected is shown with solid lines. Wiringwhen external input is selected is shown with broken lines.NPN output typeConnector typeCable typeI/O circuit diagramsNPN output typePNP output typeNotes: 1) The quick-connection sub cable does not have brown lead wire and blue leadwire. The power is supplied from the connector of the main cable.2) The quick-connection cable does not have gray or pink lead wires.Wiring diagramsTerminal layout of connector typeColor code of cable type / quick-connection cable Color code of cable type / quick-connection cable Notes: 1) The quick-connection sub cable does not have brown lead wire and blue leadwire. The power is supplied from the connector of the main cable.2) The quick-connection cable does not have gray or pink lead wires.* Connector for amplifier (CN-EP4) pin position%%Notes: 1) The quick-connection sub cable does not have +V (brown) and 0 V (blue).The power is supplied from the connector of the main cable.2) Wiring when sensing output 2 is selected is shown with solid lines. Wiringwhen external input is selected is shown with broken lines.%%%PNP output typeConnector typeCable typeSymbols ...D 1, D 2, D 3, D 4: Reverse supply polarity protection diodeZ D1, Z D2: Surge absorption zener diode Tr 1, Tr 2 : PNP output transistor056 222 38 18*********************SEN TRONIC AG249Digital Laser Sensor LS-500SERIESLS-400FIBERSENSORSPHOTO-ELECTRICSENSORSMICROPHOTO-ELECTRICSENSORSAREASENSORSLIGHTCURTAINS /SAFETYCOMPONENTSPRESSURE /FLOWSENSORSINDUCTIVEPROXIMITYSENSORSPARTICULARUSESENSORSSENSOROPTIONSSIMPLEWIRE-SAVINGUNITSWIRE-SAVINGSYSTEMSMEASURE-MENTSENSORSSTATICELECTRICITYPREVENTIONDEVICESLASERMARKERSPLCHUMANMACHINEINTERFACESENERGYCONSUMPTIONVISUALIZATIONCOMPONENTSFACOMPONENTSMACHINEVISIONSYSTEMSUVCURINGSYSTEMSMetal plateAccessory forMS-EXL2-1Cautions for laser beamsPart description (Amplifier)MountingAmplifierLS-H201□, LS-H901□<How to mount the amplifier>(1) F it the rear part of the mountingsection of the amplifier on a 35 mm1.378 in width DIN rail.(2) P ress down the rear part of themounting section of the unit on the 35 mm 1.378 in widthDIN rail and fit the front part of the mounting section tothe DIN rail.<How to mount the sensor head>(1) I nsert the sensor headconnector into the inlet until itclicks.(2) Fit the cover to the connector.<How to remove the amplifier>(1) Push the amplifier forward.(2) L ift up the front part of theamplifier to remove it.Note: B e careful. If the front part is lifted without pushing the amplifier forward,Sensor headLS-H101□• The tightening torqueshould be 0.98 N·m or less.LS-H102□• In case mounting this product,use a metal plate MS-EXL2-2(accessory).• The tightening torque should be0.5 N·m or less with M3 screws.<Not requiring the metal plate><Requiring the metal plate>• In case using the dedicated sensor head mountingbracket MS-EXL2-1 (optional) when mounting thisproduct, the metal plate MS-EXL2-2 (accessory) isrequired depending on the mounting direction. Mount asthe diagram below indicates.• The tightening torqueshould be 0.5 N·m orless.• When placing the sensorhead horizontally orvertically, the reflectormust also be positionedhorizontally or verticallyas shown in Fig. 1 below. I f the sensor head is placed horizontallyor vertically but the reflector is tilted as shown in Fig. 2 below, thereflection amount will decrease, which may cause unstable detection.Safety standards for laser beam products• A laser beam can harm human being’s eyes, skin, etc.,because of its high energy density. IEC has classifiedlaser products according to the degree of hazard and thestipulated safety requirements. LS-H□ is classified asClass 1 laser.Classification by IEC 60825-1width DIN railconnector(Purchase separately)Safe use of laser products• For the purpose of preventing users from sufferinginjuries by laser products, IEC 60825-1 (Safety of laserproducts). Kindly check the standards before use.(Refer to About laser beam.)* T his product complies with 21 CFR 1040.10 and 1040.11 Laser NoticeNo. 50, dated June 24, 2007, issued by CDRH (Center for Devices andRadiological Health) under the FDA (Food and Drug Administration).056 222 38 18*********************SEN TRONICAG250Digital Laser SensorLS-500SERIESLS-400FIBER SENSORS PHOTO-ELECTRIC SENSORS MICRO PHOTO-ELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS /SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASURE-MENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACESENERGY CONSUMPTION VISUALIZATION COMPONENTS FACOMPONENTSMACHINE VISION SYSTEMS UVCURING SYSTEMSFig. 1 Proper positioningWhen placing the sensor head horizontally or vertically, the reflector shall also be positioned horizontally or vertically.Fig. 2 Improper positioningWhen placing the reflector tilted even when the sensor head is positioned horizontally or vertically.Wiring• Make sure that the power supply is off while wiring.• Verify that the supply voltage variation is within the rating.• Take care that if a voltage exceeding the rated range is applied, or if an AC power supply is directly connected, the sensor may get burnt or damaged.• If power is supplied from a commercial switching regulator, ensure that the frame ground (F.G.) terminal of the power supply is connected to an actual ground.• Make sure to use the optional quick-connection cable for the connection of the amplifier [connector type LS-501(P )]. Extension up to total 100 m 328.084 ft is possible with 0.3 mm 2, or more, cable. However, in order to reduce noise, make the wiring as short as possible. Set the supply voltage after considering the voltage drop caused by the cable’s resistance.Others• Do not use during the initial transient time (0.5 sec. approx.) after the power supply is switched on.• B ecause the sensitivity is higher in U-LG and HYPER modes than in other modes, it can be more easily affected byextraneous noise. Check the operating environment before use.Amplifier LS-501 LS-501PAmplifierLS-501-C LS-501P-CCN-74-C1 CN-74-C2 CN-74-C5Main cable (Optional)Sub cable (Optional)CN-72-C1 CN-72-C2 CN-72-C5When adding units, wiring length must not exceed 50 m 164.042 ft (for 5 to 8 amplifiers) or 20 m 65.617 ft (for 9 to 16 amplifiers). <Correct><Incorrect>056 222 38 18*********************SEN TRONIC AG251Digital Laser Sensor LS-500SERIESLS-400FIBERSENSORSPHOTO-ELECTRICSENSORSMICROPHOTO-ELECTRICSENSORSAREASENSORSLIGHTCURTAINS /SAFETYCOMPONENTSPRESSURE /FLOWSENSORSINDUCTIVEPROXIMITYSENSORSPARTICULARUSESENSORSSENSOROPTIONSSIMPLEWIRE-SAVINGUNITSWIRE-SAVINGSYSTEMSMEASURE-MENTSENSORSSTATICELECTRICITYPREVENTIONDEVICESLASERMARKERSPLCHUMANMACHINEINTERFACESENERGYCONSUMPTIONVISUALIZATIONCOMPONENTSFACOMPONENTSMACHINEVISIONSYSTEMSUVCURINGSYSTEMSLS-H101□Sensor headNote: Not incorporated on the emitter.Sensor headLS-H102□Note: Not incorporated on the emitter.LS-H201□ LS-H901□Sensor head3.156.90.8MS-DIN-E End plate (Optional)Material: Acrylic (Reflector)ABS (Base)0.1650.217Reflector (Accessory for LS-H901□)RF-330Material: Acrylic (Reflector)ABS (Base)RF-310Reflector (Optional)Reflective tape (Optional)RF-33 RF-318.5Material: Cold rolled carbon steel (SPCC)(Uni-chrome plated)MS-DIN-2Amplifier mounting bracket (Optional) 056 222 38 18*********************SEN TRONICAG252Digital Laser SensorLS-500SERIESLS-400FIBER SENSORS PHOTO-ELECTRIC SENSORS MICRO PHOTO-ELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS /SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASURE-MENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERSPLC HUMAN MACHINE INTERFACES ENERGY CONSUMPTIONVISUALIZATION COMPONENTSFACOMPONENTS MACHINE VISION SYSTEMS UVCURING SYSTEMSRear mounting bracketFoot angled mounting bracketUniversal sensor mounting bracketAssembly dimensionsMaterial: Stainless steel (SUS304)Two M3 (length 14 mm 0.551 in ) screws with washers [stainless steel (SUS304)] are attached.Material: Stainless steel (SUS304)Note: Without using the mounting plate,beam misalignment may occur.Mounting drawing with the emitter of LS-H102□Assembly dimensionsMounting drawing with the receiver of LS-H102□Note: Screws are not attached. Purchase separately.0.0590.0390.10233-M3 × 0.5 14 Note: This is the adjustable range of the movable part.Mounting drawing with the receiver of LS-H102□112 8 R13 t 1.5 MS-LS-1Sensor head mounting bracket (Accessory for LS-H201□, LS-H901□)Sensor head mounting bracket for LS-H102□ (Optional)MS-EXL2-1MS-EXL2-2Mounting plate (Accessory for LS-H102□)Sensor head mounting bracket for LS-H102□ (Optional)MS-EXL2-4Sensor head mounting bracket for LS-H102□ (Optional)MS-EXL2-5Material: Stainless steel (SUS304)Two M3 (length 14 mm 0.551 in ) screws with washers [stainless steel (SUS304)] are attached.Material: Die-cast zinc alloyTwo M3 (length 14 mm 0.551 in ) screws with washers, one M3 (length 10 mm 0.394 in ) hexagon socket-head bolt [stainless steel (SUS)], and one M3 hexagon nut [stainless steel (SUS)] are attached.056 222 38 18*********************SEN TRONIC AG。
UNIS F5000-M系列快速安装指南紫光恒越技术有限公司资料版本:6PW105-20201221Copyright © 2020 紫光恒越技术有限公司及其许可者版权所有,保留一切权利。
未经本公司书面许可,任何单位和个人不得擅自摘抄、复制本书内容的部分或全部,并不得以任何形式传播。
UNIS为紫光恒越技术有限公司的商标。
对于本手册中出现的其它公司的商标、产品标识及商品名称,由各自权利人拥有。
由于产品版本升级或其他原因,本手册内容有可能变更。
紫光恒越保留在没有任何通知或者提示的情况下对本手册的内容进行修改的权利。
本手册仅作为使用指导,紫光恒越尽全力在本手册中提供准确的信息,但是紫光恒越并不确保手册内容完全没有错误,本手册中的所有陈述、信息和建议也不构成任何明示或暗示的担保。
环境保护本产品符合关于环境保护方面的设计要求,产品的存放、使用和弃置应遵照相关国家法律、法规要求进行。
目录1快速安装指南················································································································ 1-11.1 安装前的准备············································································································· 1-11.2 安装防火墙················································································································ 1-11.2.1 安装前检查 ······································································································· 1-11.2.2 安装浮动螺母 ···································································································· 1-21.2.3 安装走线架 ······································································································· 1-31.2.4 安装挂耳·········································································································· 1-41.2.5 安装机箱到机柜 ································································································· 1-51.3 连接保护地线············································································································· 1-61.4 安装模块··················································································································· 1-61.4.1 佩戴防静电手腕 ································································································· 1-61.4.2 安装单板到机箱 ································································································· 1-71.4.3 安装电源模块到机箱 ··························································································· 1-81.5 连接电源线················································································································ 1-81.5.1 连接交流电源线 ································································································· 1-81.5.2 连接直流电源线 ································································································· 1-91.6 安装XFP/SFP+/SFP/QSFP+模块(可选) ······································································· 1-91.7 登录防火墙················································································································ 1-91 快速安装指南•UNIS F5000-M系列防火墙包括F5000-M06、F5000-M14两款产品,在不区分具体型号时,后续章节统称为F5000-M系列防火墙设备。
UV500检测器操作说明500检测器的使用和维护图2.1:检测器前面板16789111112534前面板见图2.1:以下控制和指示器位于前面板上:1)显示屏:A31/2数字显示器。
吸收值可显示到1.999AU。
当按下开关8(SAMP)时,这个显示屏显示样品相对光密度,当按下开关9(REF)时,这个显示屏显示参照光强度。
2)上升时间选择开关:一个四档旋转开关控制,能控制二级Beel滤器的过滤强度。
可选择的上升时间有0.1,0.3,1.0和3.0秒四档。
上升时间等于2倍的时间常数。
(以秒为单位)3)灵敏度选择开关:十二档的旋转开关控制仪器背板上的输出口的输出电压范围。
可供选择的有 2.0,1.0,0.5,0.2,0.1,0.05,0.02,0.01,0.005,0.002,0.001,和0.0005AUFS。
这个开关不控制仪器背板上的1V/AU积分仪输出端口的输出。
4)波长选择器:连续波长旋钮,可调范围190-800nm。
顺时针旋转降低波长,逆时针旋转增加波长。
箭头指示波长增加方向。
注意:不要强力旋转旋钮,使波长值低于180nm或高于820nm这会损坏波长控制器。
5)波长指示器:一个三位的机械波长指示器,显示当前工作波长。
6)紫外(UV)灯指示器:绿色发光二极管亮表示氘(D2)灯装于设备内并且发光。
7)可见光(VIS)灯指示器:绿色二极管灯亮表明这个设备内装着一个钨灯并且发光。
8)样品光强度开关:按下这个瞬间开关,显示器显示样品室光敏二极管测到的样品光密度。
9)参照光密度开关:也是瞬间开关,按下此开关,显示器显示参照光敏二极管测到的参照光密度。
10)短路开关:瞬时开关,按下这个按钮,记录仪输出端电压降为零伏。
这个按钮必须持续按压一会才能发挥作用。
这个按钮用于调整记录笔在记录纸上的位置,但不影响积分仪输出。
11)标记开关:瞬时开关按下该开关可产生偏转度达20%的输出信号,该开关不影响积分仪输出。
12)等待状态指示灯:绿色LED指示灯,此灯亮表示记录仪输岀端正在输出一个恒定的零电压。
Package ContentsThe u500 package includes:●Power cable●Rack mounting bracket ears with screws ●Ethernet cable ●u500 applianceu500 rear and front panelsRear PanelFront PanelConsole Console port VGAVGA port USB USB ports ExternalInternet port InternalLAN portEth2 - 6LAN port (not configured) ResetReset switch Power indicatorSystem status indicator HDD indicatorLCD keypad arrowsInstallation●Prepare the appliance for rack installation by fastening the bracket ears to the sides of the chassis using the provided hardware. ●Mount the appliance to your rack enclosure using the provided hardware.●Connect the ethernet cable from your Internet modem or router to the Internet port (External) located on the rear panel. ●Connect the ethernet cable from your LAN switch to the LAN port (Internal) located on the rear panel. ●Plug in the power cable to a power source and connect it to the AC power input located on the rear panel. ●Review the power indicator on the front of the appliance. If the indicator is lit, the appliance is powered on. ●If the appliance is not powered on, toggle the power switch located on the rear panel.Connect to the applianceYou can connect to your appliance via the online C ommand Center portal at h ttps:///cmd . Alternatively, you can connect to your appliance from the local network, or directly using a monitor, keyboard, and mouse.Via Command CenterProvisioning a new u500 appliance via Command Center is a convenient way to deploy and configure NG Firewall. To set up and manage your new appliance from Command Center follow these steps:1.Navigate your web browser to h ttps:///cmd .2.Log in with your Untangle Command Center account, or click C reate Account to set up an account.3.In Command Center, click A dd in the Appliances screen.4.Enter the serial number located on the side panel of your appliance.5.Click A dd to confirm the new appliance.6.After the appliance successfully adds to your account, you can select it from the list of appliances.7.Click R emote Access to connect to the administration of your new appliance.8.Continue to the setup wizard.Via network connectionAlternatively, you can connect to your NG Firewall management interface from the local area network. This is useful for example if your NG Firewall appliance cannot reach the Internet and you require local administration to configure the TCP/IP settings. To access theadministration from a local network follow these steps:1.Connect your management system to the network attached to the LAN port (Internal) of the appliance.2.Check the network status of your management system and confirm that you receive an IPv4 address in the subnet of192.168.2.0/24 (e.g. 192.168.2.100).3.In a browser, navigate to 192.168.2.1.4.Accept the SSL certificate notice in your browser and continue to the setup wizard.Via direct connectionIf neither of the previous options is available, you can connect to your appliance directly by attaching a display to the VGA port and a keyboard and mouse to any of the USB ports. At the menu on the bottom of the screen, click L aunch Client to open the administration in a browser and continue to the setup wizard.Configure the setup wizardWhen you connect to the administration for the first time, the setup wizard prompts you to configure the essential parameters to get your appliance up and running.Get StartedNG Firewall packages its premium features as apps. During your first login NG Firewall prompts you to install the recommended apps. If you do not have a license, some of the recommended apps run as a 14 day trial. The trial converts to a subscription once you apply a valid license. You can learn more about NG Firewall apps at h ttps:///untangle-ng-firewall/applications/.WarrantyThis appliance is covered by a one, two or three year manufacturer warranty based on the option chosen at the time of purchase. For a description of the warranty policy visit h ttp:///refund-return-policy.Support & DocumentationFor technical support availability, contact information, and troubleshooting tips visit h ttp://. Help resources are available in the online help system at h ttp://.。
Operator’s Manual500Register your machine:/registerAuthorized Service and Distributor Locator: /locatorFor use with machines having Code Numbers:13002, 13185Need Help? Call 1.888.935.3877 to talk to a Service Representative Hours of Operation:8:00 AM to 6:00 PM (ET) Mon. thru Fri.After hours?Use “Ask the Experts” at A Lincoln Service Representative will contact you no later than the following business day.For Service outside the USA:Email:*********************************Save for future referenceDate PurchasedCode: (ex: 10859)Serial: (ex: U1060512345)SECTION A:WARNINGSC ALIFORNIA PROPOSITION 65 WARNINGSWARNING: This product, when used for welding or cutting, produces fumes or gases which contain chemicals known to the State of California to cause birth defects and, in some cases, cancer. (California Health & Safety Code § 25249.5 et seq.)ARC WELDING CAN BE HAZARDOUS. PROTECTYOURSELF AND OTHERS FROM POSSIBLE SERIOUS INJURY OR DEATH. KEEP CHILDREN AWAY.PACEMAKER WEARERS SHOULD CONSULT WITH THEIR DOCTOR BEFORE OPERATING.Read and understand the following safety highlights. For additional safety information, it is strongly recommended that you purchase a copy of “Safety in Welding & Cutting - ANSI Standard Z49.1” from the American Welding Society, P.O. Box 351040, Miami, Florida 33135 or CSA Standard W117.2-1974. A Free copy of “Arc Welding Safety” booklet E205 is available from the Lincoln Electric Company, 22801 St. Clair Avenue, Cleveland, Ohio 44117-1199.BE SURE THAT ALL INSTALLATION, OPERATION,MAINTENANCE AND REPAIR PROCEDURES ARE PERFORMED ONLY BY QUALIFIED INDIVIDUALS.FOR ENGINE POWERED EQUIPMENT.1.a.Turn the engine off before troubleshootingand maintenance work unless themaintenance work requires it to be running.1.b.Operate engines in open, well-ventilated areas or vent the engineexhaust fumes outdoors. 1.c.Do not add the fuel near an open flame weldingarc or when the engine is running. Stop the with hot engine parts and igniting. Do not spill fuel when filling tank. If fuel is spilled, wipe it up and do not start engine until fumes have been eliminated.1.d. Keep all equipment safety guards, coversand devices in position and in good repair.Keep hands, hair, clothing and tools away from V-belts, gears, fans and all other moving parts when starting, operating or repairing equipment.1.e.In some cases it may be necessary to remove safety guards toperform required maintenance. Remove guards only when necessary and replace them when the maintenance requiring their removal is complete. Always use the greatest care when working near moving parts. 1.f. Do not put your hands near the engine fan. Do not attempt tooverride the governor or idler by pushing on the throttle control rods while the engine is running. 1.g.To prevent accidentally starting gasoline engines while turningthe engine or welding generator during maintenance work,disconnect the spark plug wires, distributor cap or magneto wire as appropriate. 1.h.To avoid scalding, do not remove the radiatorpressure cap when the engine is hot.ELECTRIC ANDMAGNETIC FIELDS MAY BE DANGEROUS2.a.Electric current flowing through any conductorcauses localized Electric and Magnetic Fields (EMF).Welding current creates EMF fields around welding cables and welding machines 2.b.EMF fields may interfere with some pacemakers, andwelders having a pacemaker should consult their physician before welding. 2.c.Exposure to EMF fields in welding may have other health effectswhich are now not known. 2.d.All welders should use the following procedures in order tominimize exposure to EMF fields from the welding circuit:2.d.1.Route the electrode and work cables together - Securethem with tape when possible.2.d.2.Never coil the electrode lead around your body.2.d.3.Do not place your body between the electrode and workcables. If the electrode cable is on your right side, the work cable should also be on your right side.2.d.4.Connect the work cable to the workpiece as close as pos-sible to the area being welded.2.d.5.Do not work next to welding power source.SAFETYPage Installation.......................................................................................................................Section A Technical Specifications.......................................................................................................A-1 Machine Specification...................................................................................................A-2 Safety Precautions........................................................................................................A-3 VRD (Voltage Reduction Device)..................................................................................A-3 Location and Ventilation................................................................................................A-3 Stacking........................................................................................................................A-3 Angle of Operation........................................................................................................A-3 Lifting.............................................................................................................................A-3 High Altitude Operation.................................................................................................A-4 High Temperature Operation........................................................................................A-4 Cold Weather Operation......................................................................................................A-4 Towing..................................................................................................................................A-4 Vehicle Mounting..................................................................................................................A-4 Pre-Operation Engine Service..............................................................................................A-4 Oil..................................................................................................................................A-5 Fuel...............................................................................................................................A-5 Engine Coolant..............................................................................................................A-5 Battery Connections......................................................................................................A-5 Muffler Outlet Pipe........................................................................................................A-5 Spark Arrester...............................................................................................................A-5 Remote Control.............................................................................................................A-5 Electrical Connections..........................................................................................................A-6 Machine Grounding..............................................................................................................A-6 Welding Terminals................................................................................................................A-6 Welding Output Cables........................................................................................................A-6 Cable Installation..................................................................................................................A-6 Auxiliary Power Receptacles and Plugs...............................................................................A-7 Standby Power Connections................................................................................................A-7 Connection of Lincoln Electric Wire Feeders.................................................................A-7,A-8 ________________________________________________________________________________ Operation.........................................................................................................................Section B Safety Precautions ..............................................................................................................B-1 General Description..............................................................................................................B-1 For Auxiliary Power..............................................................................................................B-1 Engine Operation..................................................................................................................B-1 Add Fuel...............................................................................................................................B-1 Break in Period.....................................................................................................................B-1 Welder Controls.............................................................................................................B-2,B-3 Engine Controls....................................................................................................................B-4 Fuel Consumption.........................................................................................................B-4 Starting and Stopping the Engine...........................................................................B-4,B-5 Welding Operation................................................................................................................B-5 Duty Cycle and Electrode Information...........................................................................B-5 Constant Current (Stick) Welding.........................................................................................B-5 Downhill Pipe (Stick) Welding.......................................................................................B-5 Tig Welding...................................................................................................................B-6 Typical Current Ranges for Tungsten Electrodes.........................................................B-6 Wire Welding-CV...........................................................................................................B-7 Arc Gouging..................................................................................................................B-7 Auxiliary Power.....................................................................................................................B-7 Simultaneous Welding and Power Loads.....................................................................B-7 Extension Cord Recommendations...............................................................................B-7 ________________________________________________________________________________ Accessories.....................................................................................................Section C Field Installed Options / Accessories ...............................................................................C-1 ________________________________________________________________________________(5) Center-Tapped to ground.NOTE: This data is for reference only. Fuel consumption is approximate and can be influenced by many factors, including engine maintenance, environmental conditions and fuel quality.VANTAGE® 500 Extension Cord Length Recommendations (Use the shortest length extension cord possible sized per the following table.)Current (Amps)1520152044Voltage Volts120120240240240Load(Watts)180024003600480095003060(9)(18)40307560(12)(9)(23)(18)755015010050(23)(15)(46)(30)(15)1258822517590(38)(27)(69)(53)(27)175138350275150(53)(42)(107)(84)(46)300225600450225(91)(69)(183)(137)(69)Maximum Allowable Cord Length in ft. (m) for Conductor SizeConductor size is based on maximum 2.0% voltage drop.14 AWG12 AWG10 AWG8 AWG 6 AWG 4 AWGTABLE B.6SAFETY PRECAUTIONSRead the Safety Precautions in the front of this manual and in the Engine Owner’s Manual before working on this machine.Keep all equipment safety guards, covers, and devices in position and in good repair. Keep hands, hair, clothing, and tools away from the gears, fans, and all other moving parts when starting, operating, or repairing the equipment.------------------------------------------------------------------------Routine MaintenanceAt the end of each day’s use, refill the fuel tank to minimize moisture condensation in the tank. Running out of fuel tends to draw dirt into the fuel system.Also, check the crankcase oil level and add oil if indicated.outlet tube to create the critical seal, there will be some initial resistance, similar to breaking the seal on a jar. Gently move the end of the filter back and forth to break the seal then rotate while pulling straight out. Avoid knocking the filter Rotate the filter while pullingstraight out.If your air cleaner has a safety filter, replace it every third primary filter change. Remove the safety filter as you would the primary filter. Make sure you cover the air cleaner outlet tube to avoid any If your air cleaner is equipped with a Vacuator Valve Visually check and physically squeeze to make sure the valve is flexible and not inverted, damaged or plugged.Inspect the new filter carefully, paying attention to If the service cover hits the filter before it is fully in place, remove the cover and push the filter (by hand) further into the air cleaner and try again. The cover should go on with no extra force.slightly, adjust itself and distribute the sealing pressure evenly. To complete a tight seal, apply pressure by hand at the outer rim of the filter, not the flexible center. (Avoid pushing on the center of the urethane end cap.) No cover pressure is required to hold the seal.NEVER use the service cover to push the filter into place! Using the cover to push the filter in could cause damage to the housing, cover Visually inspect the old filter for any signs of leaks. A streak of dust on the clean side Inspect the OldFilter for Leak CluesInspect the New Filter for DamageOuter edge of the outlet tubeInner edge of the outlet tubeThis Troubleshooting Guide is provided to help you locate and repair possible machine malfunctions.Simply follow the three-step procedure listed below.Step 1.LOCATE PROBLEM (SYMPTOM).Look under the column labeled “PROBLEM (SYMP-TOMS)”. This column describes possible symptoms that the machine may exhibit. Find the listing that best describes the symptom that the machine is exhibiting.Step 2.POSSIBLE CAUSE.The second column labeled “POSSIBLE CAUSE” lists the obvious external possibilities that may contributeto the machine symptom.Step 3.RECOMMENDED COURSE OF ACTIONThis column provides a course of action for the Possible Cause, generally it states to contact your local Lincoln Authorized Field Service Facility.If you do not understand or are unable to perform the Recommended Course of Action safely, contact your local Lincoln Authorized Field Service Facility.HOW TO USE TROUBLESHOOTING GUIDEService and Repair should only be performed by Lincoln Electric Factory Trained Personnel.Unauthorized repairs performed on this equipment may result in danger to the technician and machine operator and will invalidate your factory warranty. For your safety and to avoid Electrical Shock, please observe all safety notes and precautions detailed throughout this manual.__________________________________________________________________________VANTAGE®500VANTAGE®500ATENÇÃOJapaneseChineseKoreanArabicREAD AND UNDERSTAND THE MANUFACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES.SE RECOMIENDA LEER Y ENTENDER LAS INSTRUCCIONES DEL FABRICANTE PARA EL USO DE ESTE EQUIPO Y LOS CONSUMIBLES QUE VA A UTILIZAR, SIGA LAS MEDIDAS DE SEGURIDAD DE SU SUPERVISOR.LISEZ ET COMPRENEZ LES INSTRUCTIONS DU FABRICANT EN CE QUI REGARDE CET EQUIPMENT ET LES PRODUITS A ETRE EMPLOYES ET SUIVEZ LES PROCEDURES DE SECURITE DE VOTRE EMPLOYEUR.LESEN SIE UND BEFOLGEN SIE DIE BETRIEBSANLEITUNG DER ANLAGE UND DEN ELEKTRODENEINSATZ DES HER-STELLERS. DIE UNFALLVERHÜTUNGSVORSCHRIFTEN DES ARBEITGEBERS SIND EBENFALLS ZU BEACHTEN.ATENÇÃOJapaneseChineseKoreanArabicLEIA E COMPREENDA AS INSTRUÇÕES DO FABRICANTE PARA ESTE EQUIPAMENTO E AS PARTES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR.CUSTOMER ASSISTANCE POLICYThe business of The Lincoln Electric Company is manufacturing and selling high quality welding equipment, consumables, and cutting equipment. Our challenge is to meet the needs of our customers and to exceed their expectations. On occasion, purchasers may ask Lincoln Electric for advice or information about their use of our products. We respond to our customers based on the best information in our possession at that time. Lincoln Electric is not in a position to warrant or guarantee such advice, and assumes no liability, with respect to such information or advice. We expressly disclaim any warranty of any kind, including any warranty of fitness for any customer’s particular purpose, with respect to such information or advice. As a matter of practical consideration, we also cannot assume any responsibility for updating or correcting any such information or advice once it has been given, nor does the provision of information or advice create, expand or alter any warranty with respect to the sale of our products.Lincoln Electric is a responsive manufacturer, but the selection and use of specific products sold by Lincoln Electric is solely within the control of, and remains the sole responsibility of the customer. Many variables beyond the control of Lincoln Electric affect the results obtained in applying these types of fabrication methods and service requirements.Subject to Change – This information is accurate to the best of our knowledge at the time of printing. Please refer to for any updated information.。
Installationsanleitung für das Powerline© 2012 NETGEAR, Inc. Alle Rechte vorbehalten.Kein Teil dieser Publikation darf ohne schriftliche Genehmigung von NETGEAR, Inc. in irgendeiner Form oder Weise reproduziert, übertragen, transkribiert, in einem Datenabfragesystem gespeichert oder in irgendeine Sprache übersetzt werden.Stapeln Sie elektronische Geräte NICHT, stellen Sie Geräte NICHT in engen Räumen auf, oder legen Sie sie NICHT in Schubladen. Stellen Sie sicher, dass das Gerät in einem freien Abstand von mindestens 5 Zentimetern aufgestellt ist.Technischer SupportDanke, dass Sie sich für NETGEAR entschieden haben. Unter können Sie Ihr Produkt registrieren, die neuesten Produkt-Updates beziehen oder den Online-Support in Anspruch nehmen.Telefon (nur USA und Kanada): 1-888-NETGEARTelefon (andere Länder):Siehe /app/answers/detail/a_id/984.MarkenNETGEAR, das NETGEAR-Logo und Connect with Innovation sind Marken und/oder eingetragene Marken von NETGEAR, Inc. und/oder seiner Tochtergesellschaften in den USA und/oder anderen Ländern. Informationen können ohne vorherige Ankündigung geändert werden. Andere Marken- und Produktnamen sind eingetragene Marken oder Marken der jeweiligen Inhaber. © 2011 NETGEAR, Inc. Alle Rechte vorbehalten. NutzungsbedingungenZur Verbesserung des internen Designs, des Betriebs und/oder der Zuverlässigkeit behält NETGEAR sich das Recht vor, die in diesem Dokument beschriebenen Produkte ohne vorherige Ankündigung zu ändern. NETGEAR lehnt im Zusammenhang mit dem Einsatz oder der Anwendung der hier beschriebenen Produkte oder Schaltpläne jegliche Haftung ab.Hardware-FunktionenPower-LEDPowerline-LEDNetzwerk-LEDSecurity-TasteReset-TasteNetzwerkanschlussBeschreibung der LEDsDie LEDs zeigen den Status der Powerline-Adapter an.• Wenn Sie den Adapter anschließen, leuchtet die Power LED auf und leuchtet grün.Der Adapter ist nicht aktiv, wenn seit mehr als 10 Minuten keine Netzwerkverbindung vorhanden ist. Der Adapter wechselt in den Energiesparmodus, und die Power-LED leuchtet gelb .• Die Powerline-LED leuchtet, wenn der Adapter mindestens ein anderes kompatibles Powerline-Gerät findet.Die Funktion Pick A Plug ermöglicht Ihnen die Auswahl desAnschlusses mit der besten Übertragungsrate, zu erkennen an der Farbe der Powerline-LED:- Grün: Übertragungsrate > 80 MBit/s (am besten)- Gelb: Übertragungsrate > 50 und < 80 MBit/s (besser)- Rot: Übertragungsrate < 50 MBit/s (gut)• Die Netzwerk-LED leuchtet, wenn Sie ein eingeschaltetes Netzwerkgerät mit mindestens einem Netzwerkanschlussverbinden.TastenbeschreibungenDie Tasten an Ihren Powerline-Adaptern haben die folgenden Funktionen:• Reset-Taste — Mit der Reset-Taste kann das Powerline-Gerät auf die werkseitigen Voreinstellungen zurückgesetzt werden.Halten Sie die Reset-Taste für eine Zeitspanne von 1 bis5 Sekunden lang gedrückt, und lassen Sie sie wieder los.• Security-Taste — Die Security-Taste dient zum Festlegen der Sicherheit zwischen den Powerline-Geräten. Halten Sie dieSecurity-Taste für eine Zeitspanne von 2 bis 5 Sekunden lang gedrückt, und lassen Sie sie wieder los.Weitere Informationen zu den Einstellungen für die Sicherheit finden Sie unter Installieren der Powerline-Adapter auf Seite 7.Installieren der Powerline-AdapterAdaptern.Schritt 1:Stecken Sie diezwei Powerline-eine Steckdose.Schritt 2:Drücken Sie aufSecurity-Tastebis 5 Sekundenlang, und lassenSie sie los. DiePowerline-LEDblinkt.Die Power-LEDleuchtet auf. Diestellungen istabgeschlossen.Hinzufügen eines neuen Powerline-Adapters zum sicherenTechnischer SupportVielen Dank, dass Sie sich für Produkte von NETGEAR entschieden haben.Nach der Installation des Geräts können Sie das Produkt mit der Seriennummer, die Sie auf dem Etikett Ihres Produkts finden, unter https:// registrieren.Die Registrierung ist Voraussetzung für die Nutzung des telefonischen Supports. Die Registrierung über die NETGEAR-Website wird dringend empfohlen.Produkt-Updates und Internetsupport finden Sie unter.Weitere Informationen zur Einrichtung, Konfiguration und Verwendung Ihres Powerline-Adapters finden Sie im Benutzerhandbuch.Kompatible NETGEAR Powerline-Geräte Ihr Powerline-Adapter kann ein Powerline-Netzwerk mit diesen kompatiblen NETGEAR-Geräten teilen: XAV101, XAV1004,XAV2001, XAV1101, XAV1301, XAV1401, XAV1601, XAV2101, XAV2501, XAV2602, XAV5001, XAV5501, XAV5601 und XAV5004. Eine vollständige Liste HomePlug-AV-zertifizierter Geräte finden Sie unter /certified_products.VorschrifteneinhaltungKonformitätserklärungenDie vollständige DoC finden Sie auf der NETGEAR-Website mit der EU-Konformitätserklärung unter: /app/answers/detail/a_id/11621/. Informationen über GNU General Public License (GPL) finden Sie unter/app/answers/detail/a_id/2649.WARNUNG: Stapeln Sie elektronische Geräte NICHT, stellen Sie sie NICHT in engenRäumen oder auf Teppichboden auf, und legen Sie sie NICHT in Schubladen. Stellen Sie sicher, dass das Gerät in einem freien Abstand von mindestens 5 Zentimetern aufgestellt ist.Dieses Symbol wurde in Übereinstimmung mit der EU-Richtlinie 2002/96/EGüber Elektro- und Elektronik-Altgeräte (WEEE-Richtlinie) hier angebracht. DieEntsorgung dieses Produkts innerhalb der Europäischen Union sollte inÜbereinstimmung mit den in Ihrem Land zur Implementierung der WEEE-Richtlinie geltenden Gesetzen gehandhabt werden.NETGEAR, das NETGEAR-Logo und Connect with Innovation sind Marken und/oder eingetragene Marken von NETGEAR, Inc. und/oder seiner Tochtergesellschaften in den USA und/oder anderen Ländern. Informationen können ohne vorherige Ankündigunggeändert werden. Andere Marken- und Produktnamen sind Marken oder eingetragene Marken der jeweiligen Inhaber. © 2012 NETGEAR, Inc. Alle Rechte vorbehalten.NETGEAR, Inc.350 East Plumeria Drive San Jose, CA 95134, USAJanuar 2012。
UNI系列货梯控制系统调试维护说明书第一章 控制器组成1.1控制器外形及接口显示窗, 按键, 拨码开关示意图s 1 s2 s3 s4 s5 s6 s7 s8ESC NEXT + - ENT控制板窗口显示标号含义s1:目标层s2:平层状态0:上平层插入F39=0 X21:灭;X22亮; F39=1 X21:亮;X22灭1:上下平层插入F39=0 X21:灭;X22灭; F39=1 X21:亮;X22亮2:下平层插入F39=0 X21:亮;X22灭; F39=1 X21:灭;X22亮3:上下平层未插入F39=0 X21:亮;X22亮; F39=0 X21:灭;X22灭s3:运行状态0:自动;1:检修;3:返平层;4:消防;5:锁梯s4:安全触板状态0:正常F36=0 X43:灭;F36=1 X43:亮;1:动作F36=0 X43:亮;F36=1 X43:灭;s5:超载状态0:超载F35=0 时X3:灭;F35=1时X3:亮1:正常F35=0 时X3:亮;F35=1时X3:灭s6:设定目标层(机房呼梯)自动时,门锁闭合情况下按K2设定目标层,K4确认可以在机房呼梯s7:减速控制方式参数F31;0:时间;1:位置;2:脉冲s8:电梯当前处在的层楼1.2输入接口端子定义类型端子标号含义输入JP0-10 24V 电源24VJP0-9 0V 电源0VJP0-8 COMJP0-7 COMJP0-6 空JP0-5 P+ PG卡的电源12VJP0-4 PA PG卡的分频输出PAJP0-3 PB PG卡的分频输出PBJP0-2 X0 XN 多功能输入点JP0-1 X1 FXFK 输出接触器反馈/上下行接触器反馈JP1-10 X2 A14 自学习JP1-9 X3 CZ 超载JP1-8 X4 SJS 上减速开关JP1-7 X5 XJS 下减速开关JP1-6 X6 MS0 门锁JP1-5 X7 KMK 开门按钮JP1-4 X10 GMK 关门按钮JP1-3 X11 MZ 满载JP1-2 X12 SJ 司机JP1-1 X13 BZFK 抱闸接触器反馈JP2-10 X14 JDN 检修下行JP2-9 X15 JUP 检修上行JP2-8 X16 JX 检修JP2-7 X17 BPZB 变频器故障JP2-6 X20 JT 急停JP2-5 X21 DPC 下平层JP2-4 X22 UPC 上平层JP2-3 X23 XF 消防JP2-2 X24 A1 并行一楼轿厢按钮 (串行外招时,一楼轿厢按钮)JP2-1 X25 A2 并行二楼轿厢按钮 (串行外招时,二楼轿厢按钮)JP3-10 X26 A3 并行三楼轿厢按钮 (串行外招时,三楼轿厢按钮)JP3-9 X27 A4 并行四楼轿厢按钮 (串行外招时,四楼轿厢按钮)JP3-8 X30 A5 并行五楼轿厢按钮 (串行外招时,五楼轿厢按钮)JP3-7 X31 A6 并行二楼外招下按钮 (串行外招时,六楼轿厢按钮)JP3-6 X32 A7 并行三楼外招下按钮 (串行外招时,七楼轿厢按钮)JP3-5 X33 A8 并行四楼外招下按钮 (串行外招时,八楼轿厢按钮)JP3-4 X34 A9 并行五楼外招下按钮JP3-3 X35 A10 并行一楼外招上按钮JP3-2 X36 A11 并行二楼外招上按钮JP3-1 X37 A12 并行三楼外招上按钮JP4-10 X40 A13 并行四楼外招上按钮JP4-9 X41 KCFK 上减速开关2/快车接触器反馈JP4-8 X42 MCFK 下减速开关2/慢车接触器反馈JP4-7 X43 CB 光幕JP4-6 X44 XXW 下限位JP4-5 X45 SXW 上限位JP4-4 X46 ST 锁梯JP4-3 X47 YS 延时按钮JP4-2 X46 RX0 串行通讯JP4-1 X47 RX1 并联通讯输出JP9-1 CM0 J1,J2,J3,J4,J20,J21,J22的共线JP9-2 J1 上行KSJP9-3 J2 下行KXJP9-4 J3 基极封锁/慢车接触器JP9-5 J4 快车接触器JP9-6 J20 快车速度段/启动加速V1JP9-7 J21 检修速度段/一级减速V2JP9-8 J22 爬行速度段/二级减速V3JP9-9 CM1 J5,J6,J7的共线JP9-10 J5 前开门KKMJP8-1 J6 关门KGMJP8-2 J7 后开门KKM2JP8-3 CM2 J10,J11,J12的共线JP8-4 J10 BZ 抱闸JP8-5 J11 TC 输入接触器JP8-6 J12 KC 输出接触器JP8-7 CM3 J14的共线JP8-8 J14 到站钟JP8-9 CM4 J15的共线JP8-10 J15 照明JP7-1 空JP7-2 TX1 并联通讯JP7-3 TX1C 并联共线JP7-4 TX0 串行通讯JP7-5 Y10 超载灯JP7-6 Y11 并行五楼外招下按钮灯JP7-7 Y12 并行四楼外招下按钮灯JP7-8 Y13 并行三楼外招下按钮灯JP7-9 Y14 并行二楼外招下按钮灯JP7-10 Y15 并行四楼外招上按钮灯JP6-1 Y16 并行三楼外招上按钮灯 (串行六楼轿厢按钮灯) JP6-2 Y17 并行二楼外招上按钮灯 (串行七楼轿厢按钮灯) JP6-3 Y20 并行一楼外招上按钮灯 (串行八楼轿厢按钮灯) JP6-4 Y21 并行一楼轿厢按钮灯 (串行一楼轿厢按钮灯) JP6-5 Y22 并行二楼轿厢按钮灯 (串行二楼轿厢按钮灯) JP6-6 Y23 并行三楼轿厢按钮灯 (串行三楼轿厢按钮灯) JP6-7 Y24 并行四楼轿厢按钮灯 (串行四楼轿厢按钮灯) JP6-8 Y25 并行五楼轿厢按钮灯 (串行五楼轿厢按钮灯) JP6-9 Y26 检修灯JP6-10 Y27 下箭头JP5-1 Y30 上箭头JP5-2 Y34 DJP5-3 Y35 CJP5-4 Y36 BJP5-5 Y37 AJP5-6 Y40 显示负号JP5-7 Y41 延时按钮灯JP5-8 Y7 蜂鸣器JP5-9 J16 显示板的24VJP5-10 空1.4 控制系统参数表要修改参数时主板重新上电并按住K0,进入设置参数状态:先输入密码,按K2键数据加一;按K3键数据减一;按K1键数据左移一位,密码是四位数据,设置好密码后按K4键确认 (出厂密码设置为1234,修改F29,F30的参数可以改变密码)进入修改参数状按K0 按K1 ; 按K2键参数值数据加一; 按K3键参数值数据减一; 按K4键确认 ;参数修改好后重新上电。
此时不能按住K0键第二章系统功能2.1 基本功能2.1.1 急停保护X20安全回路断开,电梯立刻停止运行2.1.2 检修运行X16检修断开进入检修模式2.1.3 有司机运行司机运行时,(X12断开)可以通过设置参数F7配置是否响应外招:F7=0:响应外招;F7=1:不响应外招;有外招信号时操纵箱对应的层楼按钮灯会闪烁。
2.1.4 超载保护F35=0时,X3断开超载;F35=1时,X3接通超载2.1.5 满载运行X11接通满载动作,此时不再响应外招信号2.1.6 安全触板信号选择F36=0时,X43接通安全触板动作;F36=1时,X43断开安全触板动作2.1.7 自动运行自动运行时,对门锁侦测,门锁粘连不再启动2.1.8 节能输出节能输出可以通过参数F33配置常闭输出或常开输出2.1.9 消防X23短接消防,到达基站层后电梯开门,不再关门2.1.10 锁梯X46 断开锁梯,到达基站层后,开一次门,自动关门后显示黑屏,不再响应指令。
2.1.11 开门时间设定F3是开门时间设定范围:30—250 单位:0.1秒2.1.12 自动关门等待时间设定F2是自动关门等待时间设定范围:30—250 单位:0.1秒2.1.13 前后开关门配置是开关门配置:10—1F:前开门,20—2F:后开门;30—3F:前后开门。
2.1.14 层楼显示配置是显示配置:0=0 ; 1=1; 2=2; 3=3; 4=4; 5=5; 6=6;显示-1,-2,-3时-段信号由Y40输出2.1.15 计数器参数F24=1时,显示窗s1—s5显示运行次数,运行次数可以通过修改参数F26,F27,F28清零或设置。
2.1.16 延时按钮输入X47是延时按钮输入,有延时按钮按下,延时5分钟关门。
2.1.17 重复关门关门时间超过F3开门时间3秒,门锁没有接通则再开门。
重复6次后门锁没有接通则停止开门,报E06故障。
2.1.18 基站层设定设置参数F6可改变基站层2.2 特殊功能2.2.1 井道自学习2.2.2 超低层运行2.2.3 运行超时保护第三章系统调试3.1 井道开关安装说明60—故障代码显示及分析与F版的不同之处1.输入输出端口位置有调整,定义没变。
2.输出端口增加了开关门的独立共线CM2。
3.取消了拨码开关,拖动和显示设置放在参数里设置4.故障时保持故障显示的时间延长至5秒5.修改参数时增加了向下减地址的按键K0。