异烟酸—吡唑啉酮显色液的改进
- 格式:doc
- 大小:28.00 KB
- 文档页数:5
异烟酸摘要:本文对异烟酸—吡唑啉酮光度法测定水和废水中氰化物的方法进行了改进,在不改变其它步骤的前提下,以去离子水代替二甲基甲酰胺所配得的吡唑啉酮溶液及异烟酸溶液作为显色剂。
试验结果表明:改进后新方法的精密度rsd<5%,加标率回收率为92.0~105.0%,通过电镀废水和标准样品的比对试验表明,改进后的方法与标准方法对同一样品的测定结果无显著性差异,满足监测分析要求。
关键词:氰化物异烟酸—吡唑啉酮改进abstract: it improve that determination of cyanide in water and wastewater by isonicotinic acid - pyrazolonespectrophotometric methods in this paper. under the premise of without changing the other steps, with deionized water instead of dimethylformamide as worthy ofthe pyrazolone solution and iso-nicotinic acid solution as a chromogenic agent. the results showed that:the new method improved the precision rsd <5%, plus standard rate of recovery was 92.0 ~ 105.0%.electroplating wastewater and standard sample by comparison of the tests showed. the improved methods and standard methods for the determination of the same sample was no significant difference. to meet the monitoring and analysis requirements.keyword:cyanideisonicotinic acid – pyrazoloneimprove 中图分类号: o623.76+2 文献标识码: a 文章编号:前言二甲基甲酰胺(dimethylfommmide,dmf) 为一种无色、有淡胺味的液体,是工业上经常使用的有机溶剂,它和水及大部分的有机溶剂具有良好的混溶性,广泛应用于纤维、皮革、染料、有机合成及制药等工业生产中。
异烟酸吡唑啉酮比色法一.原理:在中性条件下,水样中的氰化物被氯胺T生成氯化氰,再与异烟酸作用,并经水解而生成戍稀二醛,再与吡唑啉酮进行缩合反应生成兰色的染料,其染料色度和水样中含氰量成正比。
本法的灵敏度为0.05微克,水样中的酸含量低于500毫克/升,不影响测定。
二.仪器:a)分光光度计b)25ml具塞比色管三.试剂:1. 试银灵指示剂:称取0.02克试银灵(对二甲基亚苄罗丹宁)溶于100ml丙酮溶液中2.氯化钠标准溶液:称取1.169克氯化钠(G.R.)(预先在瓷皿内经400-500℃灼烧至无爆裂声后,在干燥器冷却)于烧杯中,用蒸馏水溶解,移入1升容量瓶,稀释至标线,摇匀,此溶液为0.0200N。
3.标准硝酸银溶液配制与标定:①称取3.270克硝酸银溶于水中,稀释至1升,贮于棕色试剂瓶中,待标定后使用。
②标定:用大肚移液管吸取0。
200N氯化钠标准溶液10ml,于瓷皿中(100或150ml),加入50ml蒸馏水,同时另取一瓷皿加入60ml蒸馏水作空白。
③向溶液中加入4滴铬酸钾指示剂,用待标定的硝酸银溶液进行滴定,用玻璃棒不断搅拌,直至溶液由黄色变成砖红色为止,记下读数取其平均值V1,同样滴定空白溶液,取其平均值为V2计算:硝酸银贮备液当量浓度N=N1*10.00ml/(N1-N2)N1---氯化钠标准溶液液的当量浓度V1---滴定氯化钠标准溶液时所用硝酸银的体积〈毫升〉V2---滴定定白溶液时所用硝酸银溶液体积〈毫升〉4.铬酸钾指示剂:称取10g铬酸钾溶于少量水中,徐徐加入硝酸银溶液,至产生微橙红色沉淀为止,放置过滤,取滤液上层清液用蒸馏水稀释至100ml。
5.氢氧化钠溶液:0.025N及2%6.磷酸盐缓冲溶液(PH=7):称取16.32克磷酸二氢钾和53.96克磷酸氢二钠于烧杯内,加水溶解后稀释至1 升。
7.1%氯胺T溶液:称取1.0g氯胺T溶于水中稀释至100ml,摇匀,储于棕色瓶中,临用现配。
异烟酸-吡唑啉酮显色液的改进
异烟酸-吡唑啉酮显色液的改进
摘要:对异烟酸-吡唑啉酮光度法测定水和废水中氰化物的方法进行了改进.在不改变其它步骤的'前提下,以去离子水代替二甲基甲酰胺所配制的吡唑啉酮溶液及异烟酸溶液作为显色剂.试验结果表明,改进后的新方法精密度RSD<5%,加标回收率为92.0%~105.0%,通过电镀废水和标准样品的比对试验表明,改进后的方法与标准方法对同一样品的测定结果无显著性差异,满足监测分析要求. 作者:方淑琴 FANG Shu-qin 作者单位:南通市通州区环境监测站,江苏,南通,226300 期刊:污染防治技术Journal:POLLUTION CONTROL TECHNOLOGY 年,卷(期): 2010, 23(2) 分类号: X830.5 关键词:氰化物异烟酸-吡唑啉酮改进。
吡唑啉酮型通用染料的合成与应用研究
吡唑啉酮型通用染料是一类通用的有机染料,具有较高的褪色性和稳定性,可以用于生产各种类型的染色物质。
目前,吡唑啉酮型通用染料的合成与应用研究主要集中在以下几个方面:
1. 合成方法的研究:目前,吡唑啉酮型通用染料的合成方法主要包括基于有机溶剂和反应催化剂的方法,以及基于离子交换树脂和反应催化剂的方法。
这些方法的优点是可以实现快速、高效和低成本的合成。
2. 应用研究:目前,吡唑啉酮型通用染料已被广泛应用于纺织、化学、生物、医学等领域。
例如,用于生产纤维素染料、蛋白质染料、颜料、传感剂等。
3. 新型染料的研发:为了开发新的吡唑啉酮型通用染料,研究人员正在积极研究新的合成方法、新的催化剂和新的染色技术。
例如,通过改进催化剂和染色技术,可以实现高褪色率、高耐久性和低污染的染色。
吡唑啉酮型通用染料的合成和应用研究具有广阔的前景,对于促
进该领域的发展和进步具有重要意义。
技术应用TECHNOLOGYANDMARKETVol.26,No.4,2019异烟酸-吡唑啉酮法测定氰化氢方法的改进邓小龙(深圳市坪山区环境监测站,广东深圳518000)摘 要:在标准方法HT/T28-1999中,配制吡唑啉酮溶液的时候,吡唑啉酮需要用到N,N-二甲基酰胺,作为溶剂将其溶解。
但是N,N-二甲基酰胺是一种挥发性有机溶剂,有较大的毒性,在使用可能会吸入体内,影响实验人员的健康。
本文通过严谨的实验,论述改进方法可行性,并对方法的准确度和精确度进行验证。
关键词:吡唑啉酮;测定;实验doi:10.3969/j.issn.1006-8554.2019.04.023 实验验证1.1 主要仪器和试剂主要仪器:Lamnda25紫外可见分光光度计试剂:①异烟酸-吡唑啉酮溶液:异烟酸溶液(A):1.25g异烟酸溶于24mL2%NaOH溶液;吡唑啉酮溶液(B):0.21g吡唑啉酮溶于76mL纯水(于70℃水溶解),将AB溶液混合制成100mL异烟酸-吡唑啉酮溶液。
②氯胺T;磷酸盐缓冲溶液;酚酞指示剂;乙酸溶液。
③氰化钾标准使用液。
1.2 实验过程1.2.1 标准曲线绘制与样品的测定向标准曲线比色管与样品比色管各加1滴0.1%酚酞指示剂,边摇动边逐滴加入0.6%乙酸溶液溶液至刚好褪色为止,加磷酸盐缓冲溶液5.00mL,摇匀。
再加氯胺T溶液0.2mL,立即盖好瓶塞,轻轻摇动,放置5min,加异烟酸-吡唑啉酮溶液5.00mL,立即盖好瓶塞,摇匀,用水稀释至标线,摇匀。
在25℃~35℃放置40min,于波长638nm处,用10mm比色皿,以水为参比,测定吸光度。
以吸光度对氰化氢含量(ug)绘制标准曲线,并计算其线性回归方程,如表1~表4所示。
表1 氰化钾标准曲线管号01234567氰化钾标准使用液0.000.200.501.002.003.004.005.000.1mol/L氢氧化钠吸收液5.004.804.504.003.002.001.000.00氰化氢含量(ug)0.000.200.501.002.003.004.005.00表2 显色温度10℃吸光度氰化氢含量(ug)0.000.200.501.002.003.004.005.00质控样吸光度质控样浓度20min0.0010.0110.0380.0850.1910.2960.4000.5010.0590.133mg/L30min0.0010.0120.040.0930.1990.3120.4260.5360.0620.134mg/L40min0.0020.0150.0480.1030.2240.3460.4620.5770.0730.137mg/L50min0.0020.0160.0580.1120.2480.3590.5020.6130.0820.140mg/L60min0.0020.0160.060.1160.2520.3650.5060.6180.0870.144mg/L表3 显色温度20℃吸光度氰化氢含量(ug)0.000.200.501.002.003.004.005.00质控样吸光度质控样浓度20min0.0010.0110.0420.0930.2110.3260.4410.5610.0640.135mg/L30min0.0020.0130.0480.1020.2350.3530.4660.5960.0730.137mg/L40min0.0020.0160.0550.110.2540.3710.5120.6270.0850.144mg/L50min0.0020.0180.0620.1180.2580.3770.5220.6330.0900.146mg/L60min0.0020.0190.0610.1160.2520.370.5160.6220.0890.146mg/L07技术与市场技术应用2019年第26卷第4期表4 显色温度30℃吸光度氰化氢含量(ug)0.000.200.501.002.003.004.005.00质控样吸光度质控样浓度20min0.0010.0120.0450.1050.2310.3560.4910.6110.0730.139mg/L30min0.0020.0180.0580.1120.2550.390.5260.6460.0890.145mg/L40min0.0030.0210.0610.1290.2640.40.5320.6570.0950.146mg/L50min0.0020.020.0620.1280.2620.3970.530.6530.0940.145mg/L60min0.0020.0170.0570.1260.2590.3940.5260.6480.0910.145mg/L1.2.2 质控样测定质控样测定:测定步骤同标准曲线的绘制。
异烟酸—吡唑啉酮显色液的改进
摘要:本文对异烟酸—吡唑啉酮光度法测定水和废水中氰化物的方法进行了改进,在不改变其它步骤的前提下,以去离子水代替二甲基甲酰胺所配得的吡唑啉酮溶液及异烟酸溶液作为显色剂。
试验结果表明:改进后新方法的精密度RSD<5%,加标率回收率为92.0~105.0%,通过电镀废水和标准样品的比对试验表明,改进后的方法与标准方法对同一样品的测定结果无显著性差异,满足监测分析要求。
关键词:氰化物异烟酸—吡唑啉酮改进
Abstract: It improve that determination of cyanide in water and wastewater by isonicotinic acid - pyrazolonespectrophotometric methods in this paper. Under the premise of without changing the other steps, With deionized water instead of dimethylformamide as worthy ofthe pyrazolone solution and iso-nicotinic acid solution as a chromogenic agent. The results showed that:The new method improved the precision RSD <5%, plus standard rate of recovery was 92.0 ~ 105.0%.Electroplating wastewater and standard sample by comparison of the tests showed. The improved methods and standard methods for the determination of the same sample was no significant difference. To meet the monitoring and analysis requirements.
Keyword:CyanideIsonicotinic acid – pyrazoloneImprove
前言
二甲基甲酰胺(Dimethylfommmide,DMF) 为一种无色、有淡胺味的液体,是工业上经常使用的有机溶剂,它和水及大部分的有机溶剂具有良好的混溶性,广泛应用于纤维、皮革、染料、有机合成及制药等工业生产中。
[1]DMF可经呼吸道吸收,液体也可经完整的皮肤及消化道进入人体引起中毒。
在低浓度下可出现消化系统症状,表现为恶心、呕吐、食欲不振、腹痛、便秘等[2]。
目前,水和废水中的氰化物测定普遍使用异烟酸—吡唑啉酮光度法,而吡唑啉酮溶液需二甲基甲酰胺溶解,为避免使用有毒试剂DMF,笔者采用去离子水代替二甲基甲酰胺溶解吡唑啉酮得新的吡唑啉酮溶液,以此新的吡唑啉酮溶液和异烟酸溶液作显色液(简称改进显色液),测定水和废水中的氰化物。
改进法避免了实验室分析人员使用有毒试剂二甲基甲酰胺,不仅有益操作者身体健康,也节约了成本,值得推广。
1 实验
1.1 仪器:722S型分光光度计,恒温水浴锅;25亳升具塞比色管[3]。
1.2 试剂:
1.2.1、显色液(异烟酸-吡唑啉酮溶液):
(1) 异烟酸溶液:称取1.25g异烟酸溶于24mL2%氢氧化钠溶液中。
(2) 吡唑啉酮溶液:称取0.21g1—苯基3—甲基5—吡唑啉酮,加去离子水76mL于70℃水浴中加热溶解。
临用前将(1)、(2)两溶液合并混匀。
1.2.2 磷酸盐缓冲液(PH=7):称取16.32g磷酸二氢钾及53.96g磷酸氢二钠,加水溶解后稀释至1L,摇匀。
1.2.3 其余试剂同标准方法
1.3 实验部分[4]
操作步骤同标准方法[5]。
1.3.1 显色温度:(25-35)℃
1.3.2 波长638nm
1.3.3 显色液体积对吸光度影响
于7支具塞比色管中加入2.00 ml氰化钾标准使用液(1.00μg/mL),另取7支具塞比色管中加入5.00 ml氰化钾标准使用液,于上述两组比色管中分别加入2.00 ml、3.00 ml、4.00 ml、5.00 ml、6.00 ml、7.00 ml、8.00 ml显色液,其余所加试剂、操作步骤同标准方法,结果见表1。
表1不同体积显色液吸光度
由表1可见,加入的显色液体积在4.00-6.00 ml范围内,吸光度达到最大,超出此范围,均显著降低,因此,笔者选用显色液使用量为5.00 ml,进行以下测定。
1.3.4 显色时间及稳定性
于比色管中加入氰化钾标准使用液3.00 ml,分别加入原显色液和改进的显色液,放入同一水浴锅中,设定温度为30℃,显色。
同时,开始计时,在25min、30min、35min、40min、45min、60min、70min时间点测定,结果见表2。
表2显色时间及稳定性
由表2可见,显色40min后吸光度达到最大,之后有所下降,但在60min 内降低甚微,稳定性亦好,因此选用显色时间为40min,且应尽快比色。
实验中发现,显色温度增高,反应速度快,有色物质的稳定时间相对缩短,但若吸光度达到最高值后立即移到低温处进行比色,则稳定时间可相对延长。
采用国标方法规定的显色时同样有此现象。
1.3.5 标准曲线的比较
于两组已加入标准系列的比色管中分别加入原显色液和改进的显色液,分别测定其吸光度,结果表明,校准曲线相关性良好,相关系数大于0.999,且改进显色液的灵敏度较原显色液的有所提高,结果见表3。
表3:标准曲线的比较
2分析结果比较:
2.1精密度
分别采用原显色液和改进显色液测定通州市南兴培德喷镀厂污水样,进行精密度试验,结果见表4。
表4 精密度试验结果
由表4可见,改进法测定水样的精密度好,相对标准偏差RSD<5%,对改进法和标准法的测定结果进行t检验[6],t=1.887,给定a=0.05,查表得t0.05(5)=2.571,因1.887<2.571,故改进法与标准法测定结果无显著性差异。
2.2准确度
分别采用原显色液和改进显色液测定通州闻天五金镀饰公司污水样,进行加标回收率试验,结果见表5。
表5加标回收率试验结果
由表5可知:改进后的方法,加标回收率在93.0~104.0%之间,加标回收率与原方法相仿,符合氰化物分析的质量要求。
2.3标准样品
对国家环保局标准样品研究所的氰化物标准样品(202239), 其保证值为(60.7±5.4)μg/L,采用原显色液和改进显色液进行测定,测定结果见表6。
表6标准样品202239试验结果
通过对氰化物标准样品202239(国家环境保护局标准研究所)的测定表明,改进法测定结果更接近标准样品真值,且精密度也好。
3小结
试验表明,用改进的显色液测定氰化物的条件与标准方法所述一致。
改进后的方法精密度好,相对标准偏差RSD<5%,灵敏度比用原显色液有所提高。
对改进法和标准法的测定结果进行t检验,两种方法无显著性差异。
笔者还对国家
环保局标准样品研究所的标准样品进行了测定,从标准物质的测定结果看,用改进的显色液与原显色液无显著性差异,结果在其保证值范围内,表明该方法准确度可靠,加标回收率在93.0~104.0%之间,满足分析要求。
同时,改进后的显色液避免了使用有毒的二甲基甲酰胺作显色液,不仅对操作者健康有益,且可降低成本,具有较大的实用价值。
参考文献:
[1] 工业毒理学[M]上海人民出版社1997.66
[2] 工业企业设计卫生标准TJ36-99.10
[3] 国家环境保护总局《水和废水监测分析方法》编委会, 《水和废水监测分析方法》(四版)[M]北京:中国环境科学出版社2006.149-152
[4]《水和废水监测分析方法指南》[M] 中国环境科学出版社1990.104-117
[5] 中华人民共和国国家标准(GB7486-87)水质氰化物的测定异烟酸—吡唑啉酮比色法
[6]中国环境监测站《环境水质监测质量保证手册》编写组编《环境水质监测质量保证手册》[M]化学工业出版社1994.231-300。