DATACENTER POWER CONSUMPTION
- 格式:pdf
- 大小:583.82 KB
- 文档页数:12
Data SheetFujitsu Display B24-9 TEWidescreen 60.5 cm (23.8-inch) Advanced Ergonomic DisplayIdeal for office applications and 24/7 usageThe FUJITSU Display B24-9 TE is a widescreen display with 1920 x 1080 Full HD resolution with a ultra-thin bezel housing. The monitor has a wide viewing angle that delivers consistent picture quality and DisplayView™ manageability software for further enhancing monitor features with a range of connectivity options ideal for medium- and large-sized businesses.The 23.8-inch display with 16:9 aspect ratio at Full HD resolution for consistent clarity and superior viewing experience is ideal for office applications.The 6-in-1 stand base allows users to tilt, swivel, adjust height, and rotate monitor display as per their comfort and working style.The ultra-thin bezel housing on three sides for multi-monitoring scenarios and integrated speakers and cable guide allow for a clean desk experience.The always available USB, DisplayPort, HDMI interfaces ensure to have a complete package that meets all your business requirements.The ergonomic stand with height adjust with 345° swivel, 35° rear tilt and 45 mm picture over desk enables for an enhanced flexibility.The environmental-friendly LED technology with highly efficient energy saving functions like ECO Operation mode and ECO standy help to save on costs.The DisplayView software enables you to configure your monitor for adjusting screen brightness, pivot function and much more.Focusing on environmental friendliness, the packaging is styrofoam free andsolely consisting of cardboard, which is more than 90% recycled.Technical detailsSpecial featuresIn-Plane Switching (IPS) technologyLow blue light mode6-in-1 StandEco button for Eco mode and 3-coloured Eco status LEDAlways available USB (in operating and standby mode)DisplayView™ Software24/7 usageIntegrated speakersErgonomic standStand6-in-1 StandHeight adjust range150 mmPicture height over desk (min)45 mmRotation to portrait90°Tilt angle-5° / +35°Swivel angle345°Picture performancePanel and backlit In-Plane Switching (IPS) technology/LEDScreen Surface Treatment Anti-glare, 3H hard coatingContrast - typical1,000:1Contrast - advanced20,000,000:1Response time gray to gray typical 5 ms (in video mode)Viewing angle (h/v) - typical178°/178° CR10:1Color performance16.7 million colorsBrightness - typical250 cd/m2Size and resolutionAspect ratio16:9Diagonal Size60.5 cm (23.8-inch)Resolution (native)1,920 x 1,080 pixelResolution (interpolated)1,680 x 1,050 pixel, 1,440 x 900 pixel, 1,280 x 1,024 pixel, 1,280 x 720 pixel, 1,024 x 768 pixel, 800 x 600 pixel, 640 x480 pixelPicture size527 x 296 mmPixel Pitch0.2745 mmFrequenciesHorizontal30 - 82 kHzVertical48 - 76 HzConnectivityDisplayPort 1 x DisplayPort 1.2HDMI 1 x HDMI 1.4VGA/D-SUB 1 x D-SUBAudio signal output 3.5 mm stereo phone jack for head phoneAudio sound output 2 x 2 WAudio signal input 3.5 mm stereo phone jackUSB downstream2x USB 3.2 Gen1USB upstream 1 x USB 3.2 Gen1Ease-of-use menuDirect Access Keys Brightness, ECO, Input, Mode, Audio, MenuLanguages Arabic, Czech, Danish, Dutch, English, Finnish, French, German, Italian, Norwegian, Polish, Portuguese, Russian,Spanish, Swedish, Turkish, Japanese, Chinese simply, Chinese traditionalBrightness / Contrast Brightness, Contrast, Black level, Auto level, ACRMode sRGB, Office, Photo, Video, Low Blue LightColor sRGB, 5000K, 6500K, 7500K, Native, Custom Color (R,G,B)OSD Language, OSD-Timeout, OSD rotationImage adjust Clock, Phase, H-Position, V-Position, Expansion, SharpnessAudio Mute, Volume, Input for HDMI and DP interfaceInformation Model name, Serial number, Signal input, Resolution/mode, Display mode , Color Temperature, ACR Status Advanced settings Overdrive, DDC/CI, Factory RecallPower consumption (typical, w/o sound)Soft switch off0.1 WPower save mode0.17 WOperating with EPA settings14.25 WTotal Energy Consumption (ETEC)44.66 kWh/yearOperating maximum brightness22 WPower supply integratedPower notes Speakers off, USB not connectedETEC and EPA refer to ENERGY STAR® 8.0Electrical valuesRated voltage range100 V - 240 VRated frequency range50 Hz - 60 HzProtection class1ComplianceModel DY24-9TGlobal ENERGY STAR® 8.0, TÜV Low Blue Light Certified, TÜV Flicker Free Certified, Zero bright and dark pixel faults, Subpixelfaults according to ISO9241-307 (Pixel fault class I), EPEAT® Silver (dedicated regions), TCO CertifiedEurope EN 62368-1, CE certification according to EC Directive 2004/108/EEC, RoHS, WEEE, IT-Eco-DeclarationAustralia/New Zealand RCMChina CCCGermany TÜV GSRussia EACSingapore S-MarkSouth Korea KCTaiwan BSMIUSA/Canada FCC Class B, cTUVusCompliance link https:///sites/certificatesDimensions / Weight / EnvironmentalDimension without stand (W x D x H)540.3 x 64 x 325.6 mm21.27 x 2.52 x 12.82 inchDimension with stand (W x D x H)540.3 x 229.4 x 346.2 mm21.27 inch x 9.03 x 13.63 inchWeight (unpacked) 5.25 kg11.57 lbsWeight (Monitor only) 3.21 kg7.08 lbsOperating ambient temperature 5 - 35 °C (41 - 95 °F)Operating relative humidity10 - 85 % (non condensing)MiscellaneousMiscellaneous VESA DDC/ CI, Flat Display Mounting Interface VESA MIS-D 100 C, Kensington lock preparedColor Marble greyAdditional SoftwareAdditional software (optional)WINDOWS WHQL driverDisplayView SuiteAdditional software (notes)Use of accompanying and/or additional Software is subject to proactive acceptance of the respective LicenseAgreements /EULAs/ Subscription and support terms of the Software manufacturer as applicable for the relevantSoftware whether preinstalled or optional. The software may only be available bundled with a software supportsubscription which – depending on the Software - may be subject to separate remuneration.Package contentDisplay delivered accessories DisplayPort data cable 1.8 mUSB-cable 1.8 m (USB-A to USB-B)Power cable for wall socket (Euro-Schuko-Type CEE7) 1.8 mQuickstart flyerSafety notesDisplay delivered accessories notes Power cable with IEC-60320-C13, 3-pin connector on display sideData cables and USB cable detachable on displayUser manual and DisplayView Software is available via downloadPackaging dimension (mm)655 x 411 x 220 mmPackaging dimension (inch)25.79 x 16.18 x 8.66 inchWeight (packed)7.1 kgWeight (packed) (lbs)15.65 lbsOrder informationOrder Code S26361-K1713-V140EAN Code4065221888260Country specific order code BDL:K1713V140-UK - with UK power cable, mandatory for Arabian countriesBDL:K1713V140-CHN - with China power cable and CEL, mandatory for ChinaBDL:K1713V140-INT - W/o power cable, mandatory for countries where import with EU cable is not allowed Accessories information Further helpful options:Stands and Mounting kits:/fts/products/computing/peripheral/accessories/desktop/ums/index.htmlAvailable Adapters: /dmsp/Publications/public/pos-connectivity.pdfWarrantyWarranty period 3 years (depending on country)Warranty Terms & Conditions /warrantyDigital bug fixes Subject to availability and following their generic release for the product, bug fixes and function-preserving patchesfor product-related software (firmware) can be downloaded from the technical support at: https://support.ts.fujitsu.com/ free of charge by entering the respective product serial number. For application software supplied togetherwith the product, please directly refer to the support websites of the respective software manufacturer.Spare Parts availability at least 7 years after shipment, for details see https:///Service Weblink /emeia/products/product-support-services/CONTACTFujitsu Technology Solutions GmbH Website: 2023-11-27 EM-ENworldwide project for reducing burdens on the environment.Using our global know-how, we aim to contribute to the creation of a sustainable environment for future generations through IT.Please find further information at http://www./global/about/environmenttechnical specification with the maximum selection of components for the named system and not the detailed scope ofdelivery. The scope of delivery is defined by the selection of components at the time of ordering.Technical data is subject to modification and delivery subject to availability. Any liability that the data and illustrations are complete, actual or correct is excluded. Designations may be trademarks and/or copyrights of the respective owner, the use of which by third parties for their own purposes may infringe the rights of such owner.The overall product has been designed and manufactured for general office use, regular personal use and ordinary industrial use.More informationAll rights reserved, including intellectual property rights. Designations may be trademarks and/or copyrights of therespective owner, the use of which by third parties for their own purposes may infringe the rights of such owner. For further information see https:///global/about/resources/terms/ Copyright 2023 Fujitsu Technology Solutions GmbH。
SamsungZ-SSDSZ985Ultra-low Latency SSD for Enterprise and Data CentersBrochureSamsung Z-SSD SZ985 offers more capacity than PRAM-based data center SSDs, with comparable latency and higher enduranceWe live in a world where new applications are continuously debuting, and Big Data, IoT, and other applications generate enormous amount of data every day. Meanwhile, data centers are always looking for better storage architecture to manage data generated by a variety of applications. SATA SSDs are taking the place of HDDs in datacenters and recently, high-performance NVMe SSDs are gaining momentum in premium storage services and in storage for high-end virtual machines. However, another level of requirements for high performance storage targeting cache and real-time data analytics is rising. Fulfilling those requirements using memory is too expensive to scale and the existing storage technology is farbelow the required performance standards.Samsung Z-SSD SZ985, a new type of performance SSD, is specially designed for enterprise applications such as Database Management Systems (DBMS), data analysis, and cache, where high throughput and low latency are a must. It is an ultra-low latency NVMe SSD containing Samsung Z-NAND flash memory and a next-generation NVMe controller, supporting PCIe Gen3 x 4 lanes. The SZ985 provides sequential read and write speeds of up to 3,200 MB/s and 3,000 MB/s respectively, and is able to perform a 4 KB random read operation in 20 μs. Based on Samsung’s innovative V-NAND technology, the SZ985 offers high capacities of up to 3.2 TB of storage 1 and high endurance of 30 Drive Writes Per Day (DWPD) for up to five years. Thanks to its ultra-low latency, high read and write speeds, high capacity, and high endurance, the SZ985 is ready to create a new segment in the memory and storage market.Why Samsung SZ985?• Ultra-low Latency: Up until now the benefits of persistent storage have come at the cost of performance because storage devices are nowhere near as fast as modern processors and system memory. Therefore, we strive to make persistent storage media as fast as possible in order to achieve outstanding storage performance. The SZ985 is a high-speed NAND flash memory-based storage device that boasts 99.999% read QoS latency under 90 μs and 150 μs in 4 KB mixed random read (70%) and write (30%) at queue depths 1 2 and 16, respectively.• Consistently high performance: Since its first SSD release to the market, Samsung has been the leader in NAND flash memory based SSD technology. Using Samsung’s proven expertise and wealth of experiences in c utting-edge SSD technology and memory solutions, Samsung SSDs have helped data centers operate continually at the highest performance levels. As the number one provider of NAND flash SSDs and the manufacturer of all of its SSD components- from the raw NAND flash to the controller and firmware- Samsung ensures steady supply of NAND flash-based high performance SZ985.• Outstanding Performance and Endurance: Tests 3 show that the SZ985 achieves more than 30% higher sequential read and write throughput and 4 KB random read IOPS over PRAM-based SSDs (P-SSDs). With Samsung’s V-NAND technology as its foundation, the SZ985 provides remarkable endurance of 30 DWPD for up to five years.• High Capacity: Based on NAND flash memory technology, the SZ985 offers up to 3.2TB disk capacities, while P-SSDs can offer only much lower densities. This makes Samsung SZ985 better suited to enable data centers to continue to scale on their servers, decreasing the costs of computing.A high-speed storage device from the SSD technology leader1. 1.6 TB and 3.2 TB SSD availability schedule yet to be determined.2. Read and write latency were measured by using FIO in CentOS 7.0 and 4 KB transfer size with queue depth 1 on a random and sequential workloads of sustained state, respectively.3. Random performance was measured using FIO on CentOS 7.0 with queue depth 32 by 16 workers and sequential performance with queue depth 32 by 16 workers.Ultra-low Latency for Nimble Response TimesLatency is the most powerful feature of the SZ985, which shows stable latency QoS under various types of I/O patterns.4 KB random read and write requests are the most common I/O for SSDs. The SZ985 keeps both read and write latencies of 4 KB random I/O under 20 μs at 99.999% at queue depth 1 (QD1). Typically, SSDs reach their maximum throughput at queue depth 16 (QD16). The SZ985’s 4 KB random read latency is maintained at less than 100 μs and the write latency is around 150 μs even at 99.999%, both at queue depths of 16.High Throughput for Maximum PerformanceWe compared the SZ985 with Samsung PM963 and a P-SSD. The SZ985 provides sequential read and write speeds of up to 3,200 MB/s and 3,000 MB/s, respectively, which results in 33% and 50% better sequential read and write throughput, respectively, than those of the PRAM-based SSD.As a majority of the mission-critical workloads rely on small-sized random reads (4 KB or less), the SZ985 shows excellent performance in delivering high IOPS at low queue depth. Although the P-SSD provides higher 4KB random write IOPS, the SZ985 achieves 36% higher random read IOPS at 750K IOPS 4.SSDs have relatively poor latency in mixed workload situations compared with system memory. But the SZ985 minimizes read latencyeven while garbage collection is in progress. The SZ985 achieves 4 KB random read latency under 500 μs even at 99.9999% at queue depth 16 with 70% of the requests being 4 KB random reads and 30% being random writes.Samsung Z-SSD SZ985’s Advanced Features• Z -NAND New Flash Memory for Ultra-low Latency: Samsung developed Z-NAND, which has powerful channel speeds and read performance compared to TLC V-NAND, allowing it to achieve faster levels of data transfer. Z-NAND is based on Samsung V–NAND technology, delivering reliable and consistent performance. This new specialized NAND with a ‘unique circuit design’ dramatically reduces latency to levels on par with P- SSDs. Coupling an extra die with SLC NAND, which is much faster and more reliable than MLC and TLC NAND, provides tremendous performance, reliability, and SSD lifetime benefits.• New Generation NVMe SSD Controller: The SZ985 is powered by Samsung’s next generation NVMe controller with PCIe Gen 3 and it reaches sequential read and write performance at 3,200 MB/s and 3,000 MB/s, respectively with the SZ985. The controller provides hardware automation for read data paths which optimizes low- latency random read performance, especially with Z-NAND; automatic I/O scheduling for better QoS; higher controller operating frequency than those of previous controllers, which greatly reduces processing time; and doubled DRAM bandwidth with LPDDR4 versus the previous controller’s LPDDR3 DRAM.4. Sequential and random throughput comparisons are based on product specifications.Consistent Low Latency and Incredible PerformanceEfficient Power Consumption and Long-lasting EnduranceMore Endurance with 30 DWPD for Five YearsUtilizing Samsung Z-NAND technology, the SZ985 provides remarkable endurance of 30 DWPD for up to five years, which equates to 43.8 Petabytes Written (PBW) for an 800 GB drive. Compared with the SZ985, the PM963 provides 1.3 DWPD for three years, which equates to only 1.37 PBW. The PRAM-based P-SSD also provides 30 DWPD, but only 12.3 PBW for the 375 GB drive, which is currently its only existing drive capacity. Assuming we are given PM963, P-SSD, and SZ985 drives of the same capacity, then the SZ985 provides over 3.5 times better endurance than the P-SSD and 32 times more than the PM963. This suggests that the SZ985 is better suited to enterprise environments, especially when longer endurance is required.High Performance per Watt for Efficient Power ConsumptionSZ985 consumes maximum power of up to about 9 W for sequentialread/write, while delivering staggering performance of more than 3,000 MB/s. This equates to more than 330 MB/s per watt. In comparison, P-SSD consumed more power at almost 9 W for sequential read and 13 W for sequential write, while providing read performance of 2,700 MB/s and write performance of 2,200 MB/s. The results show that the SZ985 achieved 18% and 95% better sequential read and write performance-to-power ratios, respectively, than P-SSD.Each application has its own workload characteristics, but for manytraditional applications like database DBMS, mixed 4 KB random I/O with 70% read operations and 30% write operations is an appropriate guideline to measure the performance of devices. The SZ985 shows that its random I/O performance in mixed situations increases greatly as the queue depth grows until queue depth 16 and reaches its maximum at queue depth 32.PM963 (960 GB)P-SSD (375 GB)SZ985 (800 GB)DWPD1.33030Warranty(Years)335Petabytes Written1.3712.343.8Samsung PM963 and a PRAM-based P-SSD were compared with the SZ985. As the number of clients increased from 16 to 32, all of the drives showed increased transaction processing power, tpmC. However, when the number of clients reached 64, all of the drives showed decreased tpmC. In any case, the SZ985 shows much higher throughput, even without any change in the DBMS engine, than the PM963: 70% higher with 16 clients and almost double with 32 and 64 clients. The SZ985 was also comparable to the P-SSD in terms of transaction power and even showed slightly better numbers with 16 clients.Many enterprise applications are eager for better storage performance, especially with lower latency. We applied the SZ985 to various applications and the results were remarkable.Database Management SystemsRelational database management systems (RDBMS) are one set of ‘mission-critical’ enterprise applications and storage latencies are vital for their performance. The low latency of the SZ985 is able to dramatically enhance the performance of Line of Business applications that use traditional DBMS. TPC‐C 5 is an Online Transaction Processing (OLTP) industry standard benchmark and simulates a wholesale supplier. We measured the SZ985’s TPC-C benchmark performance for DBMS workloads on PostgreSQL, one of the most popular open source RDBMS.Graph AnalysisAs Social Networking Services spread throughout the world, another layer is added to the relationship between objects and documents via links that map them together for rapid association- for example, mapping connections on social media or finding patterns in crime data for predictive policing.FlashX performs data analytics in the form of graphs and matrices and utilizes SSDs to scale to large datasets. It is designed for a large parallel machine with fast SSDs, but it also runs efficiently in cloud environments. FlashX has its own benchmark tool to evaluate hardware. To evaluate the SZ985’s performance with the FlashX framework, we used FlashX, its Twitter graph set (42 million vertices and 1.5 billion edges), and common social analysis algorithms including PageRank.The SZ985 showed the best performance among SSDs for all graphalgorithms of the FlashX benchmark and was faster than P-SSD by 8% to 29%. This suggests that the SZ985 would be a superb choice to execute social analytics, especially in the case of serving users with real-time results.Empowering enterprise applications5. TPC-C is an on-line transaction processing benchmark from TPC (/tpcc/)Form Factor Half-height Half-lengthCapacity 8 800 GB, 1.6 TB (TBD), 3.2 TB (TBD)1Host Interface PCI Express Gen3 x4NAND flash memory Samsung Z-NAND Flash Memory Sequential Read/Write Up to 3,200 MB/s / 3,000 MB/s Random Read/Write Up to 750K IOPS / 170K IOPS Reliability (MTBF)9 2 Million HoursReliability (UBER)10 1 sector per 1017 bits readEndurance (DWPD)1130 drive writes per day within 5 years Latency - Read/Write (typical) 20/16 μs QoS - Read/Write (99%)20/20 μs6. Fatcache is memcache on SSDs (https:///twitter/fatcache)7. Twemperf is an open source project on OpenHub (https:///p/twemperf)8. 1TB = 1,000,000,000,000 Bytes, 1GB = 1,000,000,000 Bytes, Unformatted Capacity. User accessible capacity may vary depending on operating environment and formatting.9. MTBF is Mean Time Between Failure, and is the predicted elapsed time between inherent failures of a system during operation.10. Uncorrectable Bit Error Rate (UBER) is a metric for the rate of occurrence of data errors, equal to the number of data errors per bits read as specified in the JESD218 document of JEDEC standard.11. The endurance of SSDs in enterprise applications is defined as the maximum number of drive writes per day that can meet the requirements specified in the JESD218 document of JEDEC standard.Samsung SZ985 T echnical SpecificationsAbout Samsung Electronics Co., Ltd.Samsung Electronics inspires the world and shapes the future with transformative ideas and technologies. The company is redefining the worlds of TVs, smartphones, wearable devices, tablets, digital appliances, network systems, and memory, system LSI, foundry and LED solutions. For the latest news, please visit the Samsung Newsroom at .Copyright © 2018 Samsung Electronics Co., Ltd. All rights reserved. Samsung is a registered trademark of Samsung Electronics Co., Ltd. Specifications and designs are subject to change without notice. Nonmetric weights and measurements are approximate. All data were deemed correct at time of creation. Samsung is not liable for errors or omissions. All brand, product, service names and logos are trademarks and/or registered trademarks of their respective owners and are hereby recognized and acknowledged. CentOS is a trademark of Red Hat, Inc. Fio is a registered trademark of Fio Corporation.Linux is a registered trademark of Linus Torvalds.Microsoft and Windows are registered trademarks of Microsoft Corporation in the United States and/or other countries.PCI, PCI Express, PCIe and PCI-SIG are registered trademarks of PCI-SIG.For more informationFor more information about Samsung Z-SSD, visit /semiconductor .CacheMemcached is a distributed memory caching system. It is often used to speed up dynamic database-driven websites by caching data and objects in memory to reduce the number of times an external data source (such as a database or API) must be read. However, DRAM is volatile and provides challenges like power consumption and operational complexity in scaling architecture.Fatcache 6 is Memcached on SSDs. It makes memory ‘fat’ by incorporating SSD-backed storage to overcome these limitations. Twemperf 7 is a tool for measuring Memcached server performance by generating connections and requests at a high rate. The experiment shows that the SZ985 served 66% more requests than the PM963 and 7% more than P-SSD, which confirms that Samsung SZ985 is well-suited for caching purposes.。
NEC Express5800 Server Series i Modeli120Ra-e1NEC Express5800/100 Seriesi120Ra-e1Note:For Linux support, go to the NEC website at /express, or contact your local NEC sales office.Product SpecificationsProcessorsIntel ®Xeon ®Processor L5240 (3GHz/1333MHz FSB/6MB L2 Cache)Intel ® Xeon ® Processor L5215 (1.86GHz/1066MHz/6MB L2 Cache)Intel ® Xeon ® Processor L5410 (2.33GHz/1333MHz/2x6MB L2 Cache)MemoryUp to 24GB (6 x 4GB) of DDR2-667 SDRAM DIMM with ECC, x4 SDDC, and online sparingMaximum storage3.5-inch SAT A : 3TB (3 x 1TB)3.5-inch SAS : 1.35TB (3 x 450GB)**Requires an optional RAID ControllerRemovable mediaOptionExpansion slotsT otal: 2 slots*1 x PCI Express X8 1 x PCI Express X4* By replacing the standard riser card witn an optional Riser Card [N8116-19], a low profile PCI-Express x8 slot and a full height 64bit/100MHz PCI-X slot become available.VideoIntegrated in Server Management Controller (8MB)Network2 x 1000BASE-T/100BASE-TX/10BASE-TPower consumption341VA/335WRedundant power supply–Redundant cooling fan–External interfaces2 x VGA, 1 x keyboard, 1 x mouse, 4 x USB 2.0, 1 x serial 2 x LAN, 1 x management LAN, 2 x videoOperating systemsMicrosoft ® Windows Server ® 2003, Standard/Enterprise Editions (SP1 or later)Microsoft ® Windows Server ® 2003 R2, Standard/Enterprise Editions (x64)Microsoft ® Windows Server ® 2008, Standard/Enterprise (x64) Red Hat ® Linux TMDimension and weight428W x 579D x 43H (1U)* Std: 10.8kg Max: 14.4kg*481W x 615D x 43H (including a stabilizer and protruding objects)Cat. No.E08BSGNEC EXPRESS5800For further information, please contact:• Microsoft and Windows Server are either registered trademarks or trademarks ofMicrosoft Corporation in the United States and/or other countries.• Intel and Xeon are registered trademarks or trademarks of Intel Corporation or its subsidiaries in the UnitedStates and other countries.• Linux is a trademark of Linus Torvalds.• Red Hat is a registered trademark of Red Hat, Inc. in the U.S.• All other products, brands, or trade names used in this document are trademarks or registered trademarksof their respective holders.• Specifications are subject to change without notice.。
Page 1/9Electronics & softwareComoNeoSystem for process monitoring and process optimization in plastic injection molding applications5887A _003-231e -08.23© 2015 ... 2023 Kistler Group , Eulachstraße 22, 8408 Winterthur, Switzerland Tel.+41522241111,****************, . Kistler Group This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resulting Type 5887A...ComoNeo is a process monitoring system made by Kistler that is designed to optimize, monitor and document injection molding processes based on cavity pressure. Apart from processing cavity pressures, the unit also allows for the acquisition and evaluation of contact temperatures from the mold (connection via thermocouple amplifier Type 2205A...) and signals from the injection molding machine (e.g. screw position, machine pressure, etc.).• The "Dashboard" shows all relevant process data at a glance on a single page• EO Assistant for creating and defining monitor boxes automatically• Process-oriented operating concept for easy and efficient control of the unit• Automatic mold identification for rapid mold replacement and short setup times• Integrated cycle history (data memory) holds at least 50 000 cycles (equals approximately 5 days of "non-stop" production)• Automatic calculation of the key process parameters necessary to monitor and evaluate process stability• Restart assistant: the simple way to transfer established processes from one machine to another • Automatic Hot Runner Balancing (optional)• Manual and automatic control of the switch-over point (optional)• Online-quality prediction as an additional method for separating out scrap• Multicomponent Injection Molding (optional)• Composite mold (optional)DescriptionComoNeo has been designed specifically for the requirements of injection molding processes and the needs of operators working in the production environment. Its innovative user interface combined with the capacitive multi-touch display allows the user to control the unit with maximum efficiency and perfect ease of use. Since the hardware of the unit has also been designed with functionality in mind, the connections have been separated into a mold side (connections to the injection mold) and a machine side (connections to the injection molding machine or handling device). On the mold side, one ComoNeo unit can accommodate up to 32 cavity pressure sensors and up to 16 contact temperature sensors (connection via thermocouple amplifier Type 2205A...).On the machine side, the unit offers 12 digital inputs and 24 digital outputs. The ComoNeo also makes it possible to record and analyze 4 analog machine signals (screw position, machine pressure, etc.). USB and Ethernet interfaces allow for a smooth exchange of data. Since the user interface is entirely based on Web technology, the visualization and the configuration of the ComoNeo are available on any notebook, PC, tablet, and smartphone sharing the network. Refer to the browsers recommended on this data sheet to ensure the best possible operating convenience (page 2). Up to 128 monitoring functions allow the ComoNeo to ensure reliable scrap separation on the basis of the recorded data. The selection and placement of the monitoring functions can be carried out either manually by the user or automatically by the EO Assistant built into the system. Equipped with four different operating modes, the ComoNeo can be adapted perfectly to the injection molding process. Setup and production mode are used, respectively, to optimize the settings and to activate the sorting of the parts. The unit also offers a production mode which will be activated if, for instance, a production break was detected and the injection molding machine is at a standstill. The ComoNeo is set to standby mode when no measurements are being taken. Aside from tools designed for process monitoring, the ComoNeo offers a host of process analysis and process optimization options. These options draw from an integrated cycle history that stores as a minimum 50 000 cycles. If required for more extensive analyses or for documentation purposes, the ComoNeo can be integrated into the corporate network via its Ethernet interface, making it possible for all measured data and evaluations to be transferred completely to Kistler's database ComoDataCenter.ComoNeo base unit with optional touch screen displayPage 2/95887A _003-231e -08.23© 2015 ... 2023 Kistler Group , Eulachstraße 22, 8408 Winterthur, Switzerland Tel.+41522241111,****************, . Kistler Group This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resulting Digital inputs (D-Sub 9 pin)Number 2x2TypeAC optocouplerVoltage rangeV 0 ... 30Logical input level high V ≥10Logical input level low V ≤5Input current at 24 VDC mA <5Digital inputs (D-Sub 15 pin)Number 2x4Type resistance/Z diode Voltage rangeV 0 ... 30Logical input level high V ≥10Logical input level low V ≤5Input impedancekΩ ≥8Supported browsers for visualization since ComoNeo 5.0Google Chrome (recommended)Microsoft EdgeThe ComoNeo is used in the field of plastic injection molding for:• M old trials • P rocess analysis and optimization • P rocess and production monitoring • P rocess and production documentation • P rocess control (Control of hot runner and switch over)• Process data transferTechnical dataGeneralMeasuring time min ≤40Sampling rate kHz 16BandwidthkHz 0.3 ... 5Number of evaluation objects128Dimensions excluding display LxWxH mm 198x77x148Operating temperature °C 0 … 50Voltage supplyVDC 18 … 30Power consumption excluding display W ≤15Power consumption including display W ≤50Protection class(installation mold side top) IP 53Voltage between supply points V rms <40and caseMold cavity pressure sensor connections Number 2x4 / 1x8 / 2x8 / 4x8Measuring ranges Measuring range 1 pC ±14 ... 200 Measuring range 2 pC ±200 ... 20 000Driftat 25°C pC /s <0.1 at 50°C pC/s <0.5Thermocouple amplifier Type 2205... connections for cavity wall Temperature sensors Number 1x8 / 2x8Measuring range V 0 ... ±10Common-mode voltage range V ±40Input impedance kΩ 100Voltage inputs for machine signals Number 1x4Measuring range V 0 ... ±10Common-mode voltage range V ±40Input impedance kΩ 100Page 3/95887A _003-231e -08.23© 2015 ... 2023 Kistler Group , Eulachstraße 22, 8408 Winterthur, Switzerland Tel.+41522241111,****************, . Kistler Group This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resulting Dimensional drawings ComoNeoFig. 1: Dimensions ComoNeo and base units5887A15887A25887A35887A4Dimensional drawings mounting plateFig. 2:Dimensions ComoNeo mounting plate 7.511.368Page 4/95887A _003-231e -08.23© 2015 ... 2023 Kistler Group , Eulachstraße 22, 8408 Winterthur, Switzerland Tel.+41522241111,****************, . Kistler Group This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resultingPage 5/95887A _003-231e -08.23© 2015 ... 2023 Kistler Group , Eulachstraße 22, 8408 Winterthur, Switzerland Tel.+41522241111,****************, . Kistler Group This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resultingConnections - mold sideType: Fischer 104 male 8-channelCavity pressure sensors, 8-channelType: Fischer 103 A056 male 4-channelType: M12, 5 pin femaleType: D-SUB 15 pin femaleX24, (X25)X26Cavity pressure sensors, 4-channelInductive proximity switchVoltage Input, Thermocouple Amplifiers, 8-channelPin allocation Function PIN Charge inputChannel 11X20: Channel 1 ... 8Channel 22X21: Channel 9 ... 16Channel 33X22: Channel 17 ... 24Channel 44X23: Channel 25 (32)Channel 55Channel 66Channel 77Channel 88vacant 91-WIRE 10GND11Pin allocation Function PIN Charge inputChannel 11X20: Channel 1 ... 4Channel 22X21: Channel 5 (8)Channel 33Channel 44GND 51-WIRE6Pin allocation Function PIN Voltage inputChannel 11X24: Channel 1 ... 8Channel 22X25: Channel 9 (16)Channel 33Channel 44Channel 55Channel 66Channel 77Channel 8824 VDC9Dig. Output DO 110Dig. Output DO 211Reference point DO x 121-WIRE13AGND (channel x, 1-WIRE)14EGND (24 V VDC)15Pin allocation Function PIN Proximity switch24 VDC1Factory Reset A 2Trigger3Factory Reset B 4EGND5Page 6/95887A _003-231e -08.23© 2015 ... 2023 Kistler Group , Eulachstraße 22, 8408 Winterthur, Switzerland Tel.+41522241111,****************, . Kistler Group This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resulting Connectors - machine sideType: D-SUB 15 pin femaleX10Voltage inputs for 4 machine signalsType: D-SUB 9 pin maleX12, X15Digital inputs and outputsType: D-SUB 15 pin maleX11, X14Digital inputs and outputsPin allocation FunctionPIN Voltage inputChannel 1 +1X10: Channel 1 … 4Channel 1 –2Channel 2 +3Channel 2 –4Channel 3 +5Channel 3 –6Channel 4 +7Channel 4 –824 VDC9Analog outp. AO 110AGND (channel x, AO x)11vacant 121-WIRE 13GND (1-WIRE)14EGND (24 V VDC)15Pin allocation Function PIN Digital I/O DI 1Cycle start_in 1X12: IMM 1DGND_DIx 2X15: IMM 2DI 2Universal_in 324 VDC 4DO 1Device ready 5DO 2RT Thresholds 6DO 3EO “Sorting”7DO 4Alarm8Reference point DO_x9Pin allocation Function PIN Digital I/ODI 1Reserve1_in 1X11: Auxiliary 1DI 2Reserve2_in 2X14: Auxiliary 2DI 3Reserve3_in 3DI 4Reserve4_in 4DGND_DIx_DOx 5vacant 6DO 1EO-Result1_out 7DO 2EO-Result2_out 8DO 3EO-Result3_out 9DO 4EO-Result4_out 10DO 5EO-Result5_out 11DO 6EO-Result6_out 12DO 7EO-Result7_out 13DO 8EO-Result8_out14vacant15Page 7/95887A _003-231e -08.23© 2015 ... 2023 Kistler Group , Eulachstraße 22, 8408 Winterthur, Switzerland Tel.+41522241111,****************, . Kistler Group This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resultingType: 2x RJ45USB 2.0USB DeviceType: 2x RJ45Display connection X16Type: HD-SUB 26X16Operating voltage inputUSB deviceUSB 2.0 Master X3, X4OPC UA InterfaceEthernet 10/100 (TCP/IP , PC level) X5, X6Ethernet 10/100 (field bus slave) X7, X8 (without function)Pin allocation Function PIN Operating voltage 24 VDC1EGND2Shielding (housing)3Pin Allocation Function PIN USB Device5 V 1D–2D+3GND4Pin Allocation Function PIN USB 2.0 Master5 V 1D–2D+3GND4Interface EthernetOPC variant OPC UA ServerOPC standardfollowing Euromap 77Pin Allocation Function PIN Ethernet 10/100RX+1RJ45RX–2TX+35445TX–68778Pin Allocation Function PIN Ethernet 10/100RX+1RJ45RX–2TX+35445TX–68778Pin Allocation Function PIN Display connection LVDS 2P1LVDS 2N 2LVDS CLK P 3LVDS CLK N 4BLEN 55VB 6GND 7GND 8E24V 9LVDS 1P 10LVDS 1N 11LVDS 3P 12LVDS 3N 13PWREN 145VB 155VA 16GND 17N.C.18LVDS 0P 19LVDS 0N 20USB P 21USB N 22PWM 235VA 24GND 25EGND26• Damage might be caused due to wrong wiring!Page 8/95887A _003-231e -08.23© 2015 ... 2023 Kistler Group , Eulachstraße 22, 8408 Winterthur, Switzerland Tel.+41522241111,****************, . Kistler Group This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resulting Included accessoriesType/Art. No.• Ethernet cable, crossed RJ45, length: 5 m 1200A49• Mounting plate55135343• Case feet, self-adhesive, black 65008306• Data carrier: ComoNeo, maXYmos, NCFx software and documentation • Connector for the voltage supply55145411ComoNeo software activations codes(Unlock code for subsequent activation of the software)• ComoNeoMULTIFLOW 2809A3 A ctivation of automaticHot Runner Balancing (Installation service separately: 9962E02-D1-1)• ComoNeo SWITC H 2834A2 – Activation for automatic Switch-Over detection (SLP) • ComoNeoMERGE 2834A3 – Multicomponent injection molding • ComoNeoCOMPOSITE 2834A5 – Composite mold• Customizable Sensors 2834A6 – License to connect externalsensors (0–10V) incl. choose of different units via voltage input on the mold side • ComoNeoCONNECT 2834A7 – License to activate the transfer of curve data via OPCUA interface • C omoNeoLOG 2834A8 – License for activating the extended change log (i.e. for Audit Trails)• ComoNeoLDAP 2834A9 – License to connect ComoNeo with Windows user management• ComoNeo Medical SW Bundle 2834A10 – software bundle containing 2834A8 and 2834A9• ComoNeoPREDICT 2824A1 – Online Quality prediction(in combination with StasaQC software – part of delivery)• Connection to the ComoDataCenter 2829D01ComoNeo standard accesories• Power adapter 100 … 240 VAC/24 VDC 5781B5incl. country specific cableComoNeo display for optimum visualization • 15.6“ capacitive multi-touch display 5637A1• Connecting cable display (l = 2.5 m) 1200A217A2.5• Connecting cable (l = 5 m)1200A217A5Connecting cable digital signals injection molding machine/Handling D-Sub 9 pin • Length l = 7 m 1500B43A7• Length to customer order 1500B43Asp (L min = 1 m/L max = 15 m)8-channel extension cable to 8-channel connector Type 1710B… at mold • Length l = 1 m 1997A1• Length l = 2 m 1997A2• Length l = 5 m 1997A5• Length to customer order 1997Asp (L min = 1 m/L max = 20 m)4-channel extension cable to 4-channel connector Type 1708B… at mold • Length l = 1 m 1995A1• Length l = 2 m 1995A2• Length l = 5 m 1995A5• Length to customer order 1995Asp (L min = 1 m/L max = 20 m)Additional ComoNeo accessories • ComoDataCenter 2829D… (database software for documentation and detailed analysis)• Hardware adaptor: Ethernet to RS-232 or RS-485 (for Multiflow) 2808A2Connecting cable digital signals injection molding machine/ handling D-Sub 15 pin • Length l = 7 m 1500B42A7• Length to customer order 1500B42Asp (L min = 1 m/L max = 15 m)Connecting cable analog signals injection molding machine/ handling D-Sub 15 pin • Length l = 7 m 1500B47A7• Length to customer order 1500B47Asp (L min = 1 m/L max = 15 m)• Thermocouple amplifier for 2, 4 or 8 2205B…Temperature sensors type K, J, N4-channel extension cable to thermocouple amplifierType 2205A… at mold • Length l = 2 m 1491A1A2• Length l = 5 m 1491A1A5• Length to customer order 1491A1Asp (L min = 0.3 m/L max = 20 m)Page 9/95887A _003-231e -08.23© 2015 ... 2023 Kistler Group , Eulachstraße 22, 8408 Winterthur, Switzerland Tel.+41522241111,****************, . Kistler Group This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resultingBase unitComoNeo for 8 (2x4) cavity pressure sensors1and 8 (temperatur-) Sensors via volt inputComoNeo for 8 (1x8) cavity pressure sensors2and 8 (temperatur-) Sensors via volt inputComoNeo for 16 (2x8) cavity pressure sensors3and 16 (temperatur-) sensors via volt inputComoNeo for 32 (4x8) cavity pressure sensors4and 16 (temperatur-) sensors via volt inputOrdering key ComoNeoT 8-channel Y extension cable to two thermocouple amplifiers Type 2205B… at mold • Length l = 2 m 1491A2A2• Length l = 5 m 1491A2A5• Inductive proximity switch 2231A1 including connecting cable, length l = 5 mAdapter boxes and additional cables • Adapter box 4-channel connector 5415A1 ComoNeo/BNC• Adapter box 8-channel connector 5415A2 ComoNeo/BNC• Adapter box 8-channel connector 5415A3 ComoNeo/2x4-channel connector at mold • Adapter box 4-channel connector 5415A4 ComoNeo/8-channel connector at mold1-channel extension cable to single connector at mold • Length l = 2 m 1991A2 • Length l = 5 m 1991A5 • Length to customer order 1991Asp (L min = 1 m/L max = 20 m)Other ComoNeo accessories (continued)。
NS312 User GuideVersion 1.0SilverStone Technology Co., Ltd.**************************IndexSilverStone NS312 Introduction.............................................................………4First time Hardware Installation..................................................................….4Booting up NS312...............................................................................……..….5Notice: Format Your HDD using NS312 Disk Utility format software…….10How to set up NS312................................................................................……11Identifying and using NS312 on your network...................................…………12Entering the system management page...............................................……...…171. Manage the Users and Groups....................................................……..A. To add a user........................................................................…….B. To delete a user....................................................................…….C. To place a user into a group................................................……….182. File Management.........................................................................….…..19A. File Server................................................................................…..B. FTP Server Setting....................................................................……20C. NFS Server Setting...................................................................……21D. Guest Access Setting.............................................................……..22E. Share Management..............................................................…….…233. System Settings..............................................................................…….24A. Network Setting.......................................................................….B. Time Setting............................................................................……25C. Turn Off Server.........................................................................…D. Information..............................................................................…..26E. Disk Usage...............................................................................….4. Maintenance..................................................................................……27A. Disk Utility................................................................................…B. Firmware Upgrade...............................................................………C. Save Configuration................................................................…….28D. Restore Configuration............................................................……E. Factory Reset..........................................................................…….29 Account Management...............................................................................……30Log Out........................................................................................................…What is NAS?NAS is the abbreviation of Network Attached Storage, which represents a HDD based storage box can be connected with a RJ-45 network cable. It could be accessed by all the devices located on the same IP network range, some advanced version could be also connected by a outside device (i.e. another IP network range or WWW), and would be identified as an accessible storage disk through “Network Neighborhood” (Microsoft Windows) /Apple Macintosh OS or Linux Samba, with user/group privilege setting function equipped, it could even prevent important data/files from being accessed by unauthorized people.Using a NAS, you don’t have to keep your original datacenter PC server operating all day long anymore, a smaller size, more stable, lesspower-consumption, less heat, less cost, easier to build-up device would make your life more convenient!SilverStone NS312 IntroductionWhat’s the difference?NS312, it’s not only an ease of use network storage, with it’s integrated USB clientchip, it is a dual-function HDD box, users could use it as a NAS where network connection is available or bring it as a portable HDD external enclosure,accessing it via its USB 2.0 client jack. This dual-functionality design gives users agreat deal of flexibility to access the unit anytime, anywhere.First time Hardware InstallationContent Check List:2. Quick Installation Guide1. NS312 Main Unit 3. Installation CD-ROM5. USB Connection Cable4. RJ-45 Network Cable 6. Power AdapterHard disk drive may come pre-installed or leave to user’s integration. Booting up NS312Assembly1.Put in a hard disk drive, if the NS312 version you got already has hard disk drive installed. Please skip this step and jump to step2.(1) Open the upper cover of NS312 through the top 4 screws with your hands.(2)Use the screws provided in the accessory packet, screw and secure the HDDon the bracket.(3)Place the secured HDD in the bracket with lines all connected, and put itback into the case.(4)Place the top panel and screw it back onto the case (Remember to place top panel so the heat absorbing pad is right above HDD and not above all the lines).2. Plug the attached RJ-45 cable and power adapter core into the “LAN” and“DC IN” plugs.3. Plug the other side of the RJ-45 cable into a network connection such as acable modem, router, or a hub. This is how NS312 are able to be accessed by other users off a remote area.(This is very important for NS312, when booting up, NS312 would automatically detect whether the operation mode is NAS function or USB hard disk drive external enclosure by identifying if there’s any activity from RJ-45 network side.)4. Plug the other side of the power core into the power plug.5. Press the power switch at the front panel.If NS312 is not connected to the internet, NS312 can be used as an external HDD storage device without using the network cable. Just plug USB cable, the B side to NS312, connect the other side to your computer’s USB connection, that’s all you need to do, no adjustment necessary!Notice: Format Your HDD using NS312 Disk Utility format software.After we boot up NS312 and enter the administration page, NS312 would inform us that our HDD needs to be formatted. (If we’re not using a whole new HDD here, please go directly to Control Panel → Maintenance →Disk Utility to use NS312 format tool.) To using NS312 as both a NAS and USB 2.0 HDD external enclosure, we need to format our HDD here into FAT32 file system format, please don’t use your Windows based PC/laptop to format the HDD, for Windows embedded format utility could only format a HDD partition no more than 32GB, it’s quite inconvenient if you’re using a large volume HDD in NS312.How to set up NS3121. After NS312 is booted up, use a web browser (i.e. Microsoft Internet Explorer) tologin NS312, there would be some different steps needed to be takenaccordingly.A. For users have a DHCP server in your network environment, (homeenvironment with DSL or cable modem router or office environment…)please use the CD-ROM attached SearchNAS_for_silverstone145.exeexecutive file to automatically find the assigned IP address in yourintranet for NS312. If you want to access NS312 for file transferring ratherthan managing it, simply type \\SSTNAS using web browser to enterNS312.B. For users don’t have a DHCP (Dynamic Host Configuration Protocol) basednetwork environment (no internet access or direct connection to acomputer…) please make sure the IP address of your computer islocated in 192.168.1.x range, if not, please change your original IPaddress within the 192.168.1.x address range, here, we use 192.168.1.34for example.i. For Microsoft Windows users. (we use XP Home/Professional for yourreference here)‧Please click “Start”→”Control Panel”→”Network Connections.”‧Right-click the network connection you’re using.‧Choose “Properties”→“General” tag, double-left-click InternetProtocol (TCP/IP) to enter the configuration window‧Choose “General”→”Using the following IP address,” setyour PC/NB IP address to 192.168.1.34, Netmask to 255.255.255.0‧Click “Ok” twice to complete the setting.‧Please jump to step 2 for advanced setting instruction.ii. For Apple Macintosh users. (we use OSX for your reference here) ‧Select the “Open Transport Control Panel” from the “ControlPanels” folder in the “Apple” or open the file directly with this path.“Local Macintosh Hard Disk”→”System Folder”→”ControlPanels”→”TCP/IP”)The control panel will look like this.‧Select “Using Static IP address,” set your PC/NB IP addressto 192.168.1.34, Netmask to 255.255.255.0‧Click “Ok” twice to complete the setting.‧Please jump to step 2 for advanced setting instruction.2. Log in NS312 using its default IP address “192.168.1.209,” (Non-DHCP basednetwork), if you’re under a DHCP based environment, use thedelivery-attached SearchNAS_for_silverstone145.exe to find the NS312 IPaddress or directly type the default Network Neighbor name “SSTNAS” in your computer’s file manager software to connect to NS312 user interface. Identifying and using NS312 on your networkAfter completing the hard disk format procedure, the default enabled“Anonymous access” function would enable you identify NS312 on your windowsbased “Network Neighborhood.” The default NetBEUI name of NS312 is “SSTNAS”, you could type “SSTNAS” in a file browser and access its anonymous access areafor file exchanging. Or you could simply use ourSearchNAS_for_silverstone145.exe software in the attached CDROM, it wouldautomatically find out the current NS312 locates in your LAN, double click on the NS312 being found to enter the administration page for proceeding related configurations.Insert the CD and choose “SEARCH NAS” program and click “SETUP”There will be a set of IP ADDRESS showing up on the right side, write it down.P Please enter pre-set password “admin"Go to next step after time is setOpen the Internet Explorer and enter “http://IP ADDRESS you wrote down” and press “enter”, afterward you will enter a web page, enter “admin” at the place it asks for your name and password, and you can enter setup page.(“Format HDD” after entering setup page).Entering the system management pageType in the default administrator account and password, the default account and password are both “admin” to log in, you can see the following screen1. Manage the Users and GroupsYou could manage the user accounts through “Control Panel” → “Users and Groups”.A. To add a user.i. Fill in the desired new user account and password (twice forconfirming), you could decide whether the Private folder would becreated or not, and enable/disable the disk quota.The “Disk Quota” function are not supported by using FAT32 formatHDD.ii. Click “Save” to create the account.B. To delete a user.i. Click on the account you want to delete from the “Existing Users” list.ii. Click the “Delete User” on the bottom and click “Yes” to delete.C. To place a user into a group.i. If you want to file an account into an existed Group, click the accountin the “Existing Users” list and click “Groups” on the bottom, the screenwould show the current existing Groups, you could use “Add” or“Remove” to manage the account adopting Groups level privileges,click “Save” to finish the Group setting.P.S. You could manage your groups in the same way to add/removean account.2. File ManagementNS312 is a sharing center for you to share your data, files, music, movies with authorized users by your own. Here you can set the related information for your NS312 to be recognized on the intranet where it operates.A. File ServerThrough File Server settings, you could decide what and how the userscreated on NS312 to access it.i. Windows Setting.ii. You could “enable” this setting to let NS312 be recognized by otherMicrosoft Windows based PC/NB through the “NetworkingNeighborhood.” Just set NS312 into the same “Workgroup” as yourPC/NB, then it could be identified automatically as acomputer/device by your PC/NB when you try to explore any newcomputer through “Networking Neighborhood.” If you have a WINSserver operating in your intranet, simply fill its IP address into the “WINSServer” column.B. FTP Server SettingFTP (File Transfer Protocol) is a method for you to use FTP client logging into NS312 and upload/download files. You could enable/disable the service here by check/uncheck the square and specify the transfer port (FTPdefault transfer port is 21, while it’s often attacked by hackers, we provide you the flexibility to change the port, 100~65535 would berecommended.)C. NFS Server SettingNFS (Network File System) is a service supported by Linux based system to let users access the other devices through network. NS312 supports NFS service so you can enable/disable it by check/uncheck the square here.D. Guest Access SettingWhat if someone doesn’t have an account on NS312 but wants to access it? You could enable/disable the Guest Access function to allow/forbid anonymous users entering NS312, furthermore, the “Enable Quota”function could let you limit the storage capacity assigned for anonymous users. The “Disk Quota” function are not supported by using FAT32 format HDD.To complete the setting, please click “Save” at the bottom to implement the changes you’ve made.E. Share ManagementShare Management including the functions to manage “how” you share the data/files stored on NS312.i. You could simply create a Share Name and specify the actual pathin your NS312, add a description on it.ii. Click “Windows, FTP Access” to grant the share you’ve created frombeing able to be accessed through Microsoft Windows NetworkNeighborhood and other FTP clients.iii. Click “NFS Access” to grant the share you’ve created from beingable to be accessed through NFS service clients.iv. If you want to delete a share folder, select it from the “ExistingShares” list and click “Delete Share” at the bottom.3. System SettingsHere come some settings for you to acquire the related information of NS312.A. Network SettingNS312 can automatically get its IP address under a DHCP based network environment, or it would operate with a default IP address 192.168.1.253.And you could change the IP address related settings here.i. Hostname. This is what NS312 would be identified in your network.ii. IP Address Setting.iii. The IP address related settings (DHCP/Static IP) and the DNS settings could be set up here.iv. You could also see the MAC address of NS312 here, sometimes you would need this information to set up NS312 in your networkenvironment.v. Click “Save” to store the settings.B. Time SettingYou could manually set the time settings used by NS312 or specify anexisted NTP (Network Time Protocol) server in the Internet, it wouldautomatically help you correct the time on NS312 (NTP function could ONLY work under the network environment which could connect onto Internet for correcting NS312 time)C. Turn Off ServerThis function enables you to Restart or Turn off NS312 through remote side, simply click “Restart” or “Turn off” to execute the functions.D. InformationHere you could get the NS312 related information, including the product name, model, firmware version for upgrading reference, hardwareversion, and the current IP address it uses.E. Disk UsageThrough this function, you could check the left capacity and the usage percentage of the HDD storage in NS312. You could view it from thewhole HDD view or a single user usage view by selecting it from theup-right side roll-down menu.4. MaintenanceA. Disk Utility“Disk Utility” enables you to format or execute scandisk function. Youcould format the HDD in NS312 with ext2/ext3/FAT32 format.Microsoft NTFS format is not supported in NS312.If you want to use NS312 as a USB 2.0 external enclosure for Windowssystems, please format the HDD with FAT32 format, for ext2/ext3 couldbe recognized only for UNIX/Linux based systems.B. Firmware UpgradeYou could upgrade the firmware from here. If you’re not using aSilverStone certified file for upgrading and results in the damage ofNS312, SilverStone would charge the customer for the RMA service.C. Save ConfigurationYou could backup the settings you’ve done on NS312 onto your PC/NB by this function, click “Save” and choose the destination where youwant to store the configuration settings on your PC/NB and click “OK” to download it.D. Restore ConfigurationIf you want to restore the settings, click “Browse” to locate the previous configuration settings backup you’ve made and click “Restore” toexecute the restore process.E. Factory Reset“Factory Reset” would reset all the settings on your NAS-100 back into the factory default value, please make sure you’ve made all thenecessary information/data backed up.Account ManagementYou could change the password, choose the preferred user interface language, get the account related storage usage information by entering “Personal Info” area.Only an “Admin” account can access the NS312 system related configuration (Control Panel) for setting up it, a single user account can only enter “Personal Info” area for password changing and getting storage usage information.Log OutRemember to click “Log out” to keep unknown users accessing NS312 using youraccount.。
DatasheetFujitsu SPARC Enterprise M4000 serverCombines mainframe benefits in a cost effective UNIX® format. Providing virtualization, integration and automation.A SPARC of steel Only the best with Fujitsu SPARC Enterprise Fujitsu SPARC Enterprise M4000 is a mid-range system with the same aggressive RAS features as its larger enterprise class cousins. Its compact rack mounted design however,significantly lowers the ownership price-point. Based on robust SPARC architecture and running the leading Oracle Solaris11, Fujitsu SPARC Enterprise servers are ideal forcustomers needing highly scalable, reliable servers that increase their system utilization and performance through virtualization.It features the non-stop self-healingmechanisms and rock solid, dependability needed to run departmental databases and ERP Applications. They can even be clustered for high availability across two physical partitions. Total binary compatibility fully protects your application investments, as well as provides Solaris Containers for furtherno-cost subdivision of resources. Fujitsu SPARC Enterprise M4000 is also a performance leader in its class with major business applications. The combined leverage of Fujitsu’s expertise in mission-critical computing technologies and high-performance processor design, with Oracle’s expertise in open, scalable,partition-based network computing, provides the overall flexibility to meet any task.Features and benefitsFlexible investment protectionAll SPARC64 VI dual-core processor and SPARC64VII+ quad-core Investment protection for years to come, less risk and lower cost of processor can be mixed and matched in the servers and even ownership.partitions.Scales to nearly twice the performance with the same number of Supports up to 2 physical partitions and thousands of Solaris sockets and similar space and power requirements.Containers, with dynamic reconfiguration and optional FujitsuFast deployment of new applications with total availability for PRIMECLUSTER inter-partition clustering. business critical processes.Reliability that makes you forgetEngineered with mainframe class self-healing capability. Best suited to the needs of departmental databases, financial and All circuits, processors and memory are constantly monitored to other high volume applications.ensure correct and continuous operation.Manages itself so you don’t have to.Self-managing hardware also maximizes the opportunity forapplications to work at peak performance.World’s most advanced OS, Oracle Solaris 11Whole network can be virtualized by mapping physical network Minimizes costs of server administration and maintenance entities onto virtualization entitiesApplication asset protection by non-disruptive upgradesSolaris 10 Containers can help applications run on Solaris 11 Maximum system operations time due to online systems update Boot Environment greatly reduces downtime for server updates abilityHighest security including delegated administration can minimize Protects business credibility by eliminating information exposure risks of attacks and business disruption risks.TopicsReliability that makes you forgetFlexible investment protectionWhen Fujitsu designed Fujitsu SPARC Enterprise M4000 they looked to their long mainframe heritage to provide the quality and robustness needed in an important mid-range platform. The result is a most reliable, and highly scalable, self-sustaining system. That works well with the world’s most popular business application systems anddatabases. By placing the widest range of error checking and correction systems directly into the hardware, the platform manages itself. This relieves system administrators from most of the difficult diagnostic and recovery tasks required with many other systems. Once you own Fujitsu SPARC Enterprise system you will soon forget the operational problems of the past. Like the engine management systems in the finest cars, everything is monitored and self-managed to ensure all applications work non-stop at the peak of their capability. Fujitsu has invested in your future by ensuring that new processors can be installed in existing systems. Even better they can be mixed, on the same system boards and in the same physical partitions, with previous processors. This provides unrivalled investment protection and - as you don’t need to replace servers so often - it can also reduce your overall IT spends.As advances in processor technology have continued, Fujitsu SPARC Enterprise and SPARC 64 processors provide the ability to significantly increase performance over time. You can either add more processors (up to 16 cores with Fujitsu SPARC Enterprise M4000) or employ new processors with almost twice the performance. In the latter case the increased performance comes with almost no increase in data center power consumption or additional heat management.World’s most advanced OS, Oracle SolarisTo ensure that all that performance can be fully used, support for up to 2 physical partitions and thousands of Solaris Containers lets you quickly and dynamically reconfigure the system for both existing and new business processes. Plus, in conjunction with Fujitsu PRIMECLUSTER middleware you can also implement fullymission-critical clustered solutions, between physical partitions, inside your M4000. Solaris is the only OS that has the scalability, security, and diagnostic features, to fully and quickly comprehend the situation, if a major application problem occurs. That is one of the reasons Solaris has the largest application portfolio and why it is the development platform of choice for many of the world’s major business applications.Technical detailsProcessorProcessor quantity and type 2–4x SPARC64 VII+, SPARC64 VIProcessor options SPARC64 VII+ quad-core processor (2.66GHz, 128KB L1 cache on core, 11MB L2cache per chip)SPARC64 VI dual-core processor (2.15GHz, 256KB L1 cache on core, 5MB L2 cacheper chip)MemoryMemory slots 32 slotsMemory slot type DDR2 SDRAMMemory capacity (min. – max.) 16GB–256GBMemory protection ECCExtended ECCMemory Mirroring supportMemory PatrollingMemory modules 8GB Memory Expansion (4x 2GB DIMM)16GB Memory Expansion (8x 2GB DIMM)32GB Memory Expansion (8x 4GB DIMM)64GB Memory Expansion (8x 8GB DIMM)Drive baysHard disk bay configuration 2x 2.5-inch hot-swap SASHard disk drives 300GB 2.5-inch 10,000rpm600GB 2.5-inch 10,000rpmTape drive bay configuration 1x 3.5-inch hot-swap bayTape drives DAT72 (option)Optical drive bay configuration 1x 128mm bayOptical drives CD-RW/DVD-RW (8xDVD-ROM, 6xDVD-RW, 24xCD/CD-R, 10xCD-RW)InterfacesLAN/Ethernet 2 ports (Gbit/s, RJ45)Remote Cabinet Interface (RCI) 1 portService LAN for XSCF 2 ports (10/100Mbit/s, RJ45)Service serial for XSCF 1 port (RS232C, RJ45)SlotsPCI Express 4x PCI Express (x8, full-height, short)PCI-X 1x PCI-X (64/32 bit, 66/133 MHz, 3.3V Universal, short)Note Expandable to 25 slots (PCI Express, PCI-X) when using 2x External I/OExpansion UnitsSupported operating systemsSupported operating systems SPARC64 VII+ Oracle Solaris 10 8/07 or laterOracle Solaris 11VIOracle Solaris 10 11/06 or laterSPARC64Oracle Solaris 11Operating system release link /sparcenterprise/manual/notes/Server managementService processor eXtended System Control Facility (XSCF)Supported software Enhanced Support FacilityVirtualizationVirtualization features Hardware partitioningDynamic ReconfigurationCapacity on demandSolaris ContainerR AS features P ower supply unitProcessor RAS Integer register protected by ECCL1 cache protected by parity and redundancy and L2 cache protected by ECCDynamic way degradation in L1, L2 cache and TLBHardware Instruction RetryDynamic chip/core degradationOperation of processor is recorded automaticallyRedundant components Memory (mirror configuration)Hard disk drive (software RAID)PCI card (multi-path configuration)FanPower supply unitPower systemHot-swap components Hard disk drive (software RAID)PCI cardTape drive (DAT)External I/O expansion unitsFanPower supply unitDegradation features Dynamic degradation MemoryHard disk drive (software RAID)FanPower supply unitdegradationProcessor (chip, core, cache)StaticMemoryI/O boardHard disk drivePCI cardsFanDimensions / WeightRack-mount (W x D x H) 444 x 810 x 263 mm ; 6U17.5 x 31.9 x 10.3 inches ; 6UWeight 84 kg185 lb.EnvironmentSound pressure (LpAm) 59 dB (A)Operating ambient temperature 5–35°C (depending on altitude)41–95°F (depending on altitude)Operating relative humidity 20–80%Operating altitude 0–3,000 m0–10,000 ftElectrical valuesRated voltage range AC 200–240 VRated frequency range 50/60 HzRated current max. 12–24 AActive power max. 1,692 WApparent power max. 1,763 VAHeat emission 6,091 kJ/hComplianceEurope CERoHSUSA/Canada FCCUL/CSAJapan VCCIChina Chinese RoHSKorea MICTaiwan BSMICompliance note There is general compliance with the safety requirements of major countries.National approvals required in order to satisfy statutory regulations or for otherreasons can be applied for on request.Warranty and support servicesService link /supportMore informationIn addition to Fujitsu SPARC EnterpriseM4000, Fujitsu provides a range of platform solutions. They combine reliable Fujitsu products with the best in services,know-how and worldwide partnerships.Dynamic InfrastructuresWith the Fujitsu Dynamic Infrastructures approach, Fujitsu offers a full portfolio of ITproducts, solutions and services, ranging from clients to datacenter solutions, Managed Infrastructure andInfrastructure-as-a-Service. How much you benefit from Fujitsu technologies and services depends on the level ofcooperation you choose. This takes IT flexibility and efficiency to the next level.Computing Products/global/services/computing/ - PRIMERGY: Industrial standard server - SPARC Enterprise: UNIX server- PRIMEQUEST: Mission-critical IA server - ETERNUS: Storage system - BS2000/OSD: Mainframe - GS21: Mainframe - ESPRIMO: Desktop PC - LIFEBOOK: Notebook PC - CELSIUS: WorkstationSoftware/software/- Interstage: Application infrastructure software- Systemwalker: System management software- Symfoware: Database software - PRIMECLUSTER: Clustering softwareLearn more about Fujitsu SPARC Enterprise M4000, please contact your Fujitsu sales representative, Fujitsu business partner, or visit our website.©Copyright 2010 Fujitsu Limited. Fujitsu, the Fujitsu logo, PRIMERGY,PRIMEQUEST, ETERNUS, BS2000/OSD, GS21, ESPRIMO, LIFEBOOK, CELSIUS, Interstage, Systemwalker, Symfoware, PRIMECLUSTER are trademarks or registered trademarks of Fujitsu Limited in Japan and other countries. /sparcenterprise/GLOVIA is a trademark of GLOVIAInternational LLC in the United States and other countries.Fujitsu Green Policy Innovation is ourworldwide project for reducing burdens on the environment. Using our global know-how, we aim to resolve issues ofenvironmental energy efficiency through IT. Please find further information at:UNIX is a registered trademark of The Open Group in the United States and other countries.All SPARC trademarks are trademarks or registered trademarks of SPARCInternational, Inc. in the United States and other countries./global/about/environment/Oracle and Java are registered trademarks of Oracle and/or its affiliates.Other company, product and service names may be trademarks or registeredtrademarks of their respective owners.DisclaimerTechnical data subject to modification and delivery subject to availability. Any liability that the data and illustrations are complete, actual or correct is excluded. Designations may be trademarks and/or copyrights of the respective manufacturer, the use of which by third parties for their own purposes may infringe the rights of such owner.ContactFUJITSU LIMITEDWebsite: 2011-11-11 WW-EN。
Data SheetFujitsu M10-1 ServerA high performance, compact entry-level server with high reliability that is ideal for data center integration and virtualizationThe Fujitsu M10-1The Fujitsu M10-1 server supports as many as 16 cores, large memory capacity, and a large-capacity disk in a space-saving one-rack-unit (1U) chassis. It can handle low-end and midrange enterprise applications. The Fujitsu M10-1 uses the latest SPARC64 X+ (“ten plus”) processors. Customers can enjoy the benefits of Capacity on Demand (COD) with the core-level CPU Activation feature, growing processor resources one core at a time. Innovative Software on Chip capabilities of SPARC64 X+ processors deliver dramatic performance gains by implementing key software functions directly in hardware. The Fujitsu M10-1 server enables highly flexible system configuration with a suite of built-in virtualization technologies included at no cost: Oracle VM Server for SPARC and the Oracle Solaris Zones feature of Oracle Solaris.Keep Pace with Expanding Needs The Fujitsu M10-1 server running the industry-leading Oracle Solaris operating system was designed to help IT managers reduce Total Cost of Ownership (TCO), rapidly deploy new business services, and consolidate existing sprawling systems more cost-effectively and reliably than ever. IT managers can take advantage of enterprise-class reliability, availability, and scalability (RAS) features in a 1U box and can incrementally grow capacity to satisfy their business requirements exactly as needed—with no wasted resources, improved utilization that will meet their IT needs now and into the future.Consolidate and Lower CostsThe compact and flexible FujitsuM10-1 server delivers greatly improved business efficiency. IT managers can consolidate many separate entry-level servers onto one Fujitsu M10-1 server and reduce space and power consumption. In addition to providing eco-efficiencies and mainframe-class reliability features, the Fujitsu M10-1 server is easy to manage and comes with a suite of built-in virtualization technologies at no additional cost. Combined with Oracle and partner service offerings, Fujitsu M10 enables customers to innovate to capture new revenue streams and shorten the time to market while dramatically improving throughput, energy efficiency, and service-level predictability at reduced costs.Features and Benefits◼16-core SPARC64 X+ processor and up to 1 TB of main memory ◼Superior performance for largest workloads such as ERP, BIDW, SCM, CRM, Big Data, and Analytics◼8-core 3.7 GHz SPARC64 X+ processor option for higher per-core performance ◼Do more with less: faster cores, higher productivity, fewer software licenses◼1U form factor ◼Space-saving entry-level server ideal for data centerintegration and virtualization◼Mainframe-class reliability, availability, and serviceability (RAS) capabilities ◼High availability to support the most demanding 24/7 mission-critical applications◼Core-based CPU activation ◼Ability to pay for only the resources that are needed,minimizing initial investment and avoiding expensiveupgrades◼Fast and economical system capacity growth in incrementsas small as two processor cores at a time with no downtime◼Software-on-Chip instructions implementing key software functions directly on SPARC64 X+ processors ◼Drastic performance gains for a wide range of applications such as encryption, decimal arithmetic operations, and key database functions◼Built-in no-cost virtualization: Oracle VM Server for SPARC and Oracle Solaris Zones technologies ◼Higher levels of system utilization and cost reduction with flexible resource configurations◼Massive server consolidation without the need to acquire additional software◼Supports Oracle Solaris 11 and Oracle Solaris 10, also Solaris 9 and 8 with Oracle Solaris Legacy Containers ◼Investment protection for application software as well as system management and administration expertise developed over the years avoiding costly and complex migrations◼Oracle Solaris 100% Binary Compatibility Guarantee ◼Preserving of software investments with the full binarycompatibility guarantee that the existing SPARC OracleSolaris applications would run unmodifiedTechnical DetailsProcessorCPU SPARC64 X+: 16-core or 8-core processors,Dual-threaded SPARC V9 architecture,Error Checking and Correction (ECC) protectionLevel 1 cache per core 64 K data cache and 64 K instruction cacheLevel 2 cache per processor 22 MB (16-core SPARC64 X+)24 MB (8-core SPARC64 X+)Clock speed 2.8 GHz (16-core SPARC64 X+)3.2 GHz (16-core SPARC64 X+)3.7 GHz (8-core SPARC64 X+)Software on Chip features •SIMD Single Instruction Multiple Data Vector Processing•Extended Floating-Point Registers•Decimal Floating-Point Processing. IEEE 754 standard and Oracle Numberare supported.•Cryptographic Processing. Supported algorithms: AES, DES, 3DES, RSA andSHASystemCPU One 16-core or 8-core CPUMain memory Up to 1 TB with 64 GB DIMMI/O •Three PCI Express 3.0 short, low-profile slots (eight lanes)•Up to 23 PCI Express slots with optional PCI expansion unit•4-port GbE, 1-port SAS, 2-port USBMemory bandwidth (per chip) 102 GB/secService processor OneStorageLocal storage As many as eight 600 GB or 1.2 TB internal 2.5-in. SAS HDDs or 400 GB or 800 GBeMLC SAS SSDs (can be mixed)SoftwareOperating system Control Domain:•Oracle Solaris 11.1 (plus required SRU) or later•Oracle Solaris 10 1/13 (plus required patches)Guest Domains:•Oracle Solaris 11.1 (plus required SRU) or later•Oracle Solaris 10 1/13 (plus required patches)•Oracle Solaris 10 8/11 (plus required patches)•Oracle Solaris 10 9/10 (plus required patches)Please see the Fujitsu M10/SPARC M10 Systems Product Notes manual forSRU/patch requirements.Software included •Oracle Solaris 11.3 which includes Oracle VM Server for SPARC•Oracle Solaris ZFS (default file system)Management software •XSCF monitoring/control facility•XSCF software, which manages hardware configuration and health, domainconfiguration and status, error monitor, and notificationSystem monitoring Oracle Enterprise Manager Ops Center 12c Release 2 or laterVirtualization Built-in, no-cost Oracle VM Server for SPARC and Oracle Solaris Zones provide theflexibility and power of up to 32 virtual systems in a single Fujitsu M10-1 server.Applications certified only for Oracle Solaris 8 or Oracle Solaris 9 may be installedin an Oracle Solaris legacy zone in an Oracle Solaris 10 1/13 guest domain.Reliability, Availability, and ServiceabilityKey features•End-to-end ECC protection•Guaranteed data path integrity•Automatic recovery with instruction retry•Dynamic L1 and L2 cache way degradation•ECC and Extended ECC protection for memory, memory mirroring, periodicmemory patrol, and predictive self-healing•Hardware redundancy in memory, HDD, SSD(Software RAID), PSU, and fan•Hot-pluggable HDD/SSD, PSU, and fan. Hot-plug of PCI card supported withthe PCI Expansion Unit.•Live operating system upgrades•Firmware updates during system operationEnvironmentAC power 100 V to 120 V ± 10% (50/60 Hz), 200 V to 240 V ± 10% (50/60 Hz)Power consumption Maximum 849 W (SPARC64 X+)Operating temperature •5° to 35° C (41° to 95° F) at an altitude of 0 m to 500 m•5° to 33° C (41° to 91° F) at an altitude of 501 m to 1,000m•5° to 31° C (41° to 88° F) at an altitude of 1,001 m to 1,500 m•5° to 29° C (41° to 84° F) at an altitude of 1,501 m to 3,000 mNon-operating temperature •–20° to 60° C (packed)•0° to 50°C (non-packed)Altitude Up to 3,000 m (9,843 ft.)Acoustic Noise •7.4 B (SPARC64 X+)•58 dB (SPARC64 X+)Cooling •Input voltage of 100 to 120 VAC:2,900 kJ/hr, 2,750 BTU/hr (SPARC64 X+)•Input voltage of 200 to 240 VAC:2,820 kJ/hr, 2,670 BTU/hr (SPARC64 X+)Dimensions and WeightHeight 4.25 cm (1.67 in.)Width 43.1 cm (17.0 in.)Depth 72.1 cm (28.4 in.)Weight 18 kg (39.7 lb.)RegulationsSafety •UL/CSA 60950-1, UL/CSA 62368-1, EN 60950-1, EN 62368-1, IEC 60950-1 CBscheme with all country differences, IEC 62368-1 CB scheme with all countrydifferencesEMC •Emissions: FCC 47 CFR 15, ICES-003, EN 55032, KN32, VCCI V3, EN 61000-3-2,EN 61000-3-3, JIS C 61000-3-2•Immunity: EN 55024, KN35More InformationFujitsu platform solutionsIn addition to Fujitsu M10-1, Fujitsu provides a complete range of platform solutions. These solutions combine reliable Fujitsu products with the best in services, know-how and worldwide partnerships. Dynamic InfrastructuresWith the Fujitsu Dynamic Infrastructures approach, Fujitsu offers a full portfolio of IT products, solutions and services, ranging from client systems to datacenter solutions, Managed Infrastructure services and Infrastructure-as-a-Service (IaaS) clouds. Customers can make the most beneficial choices from the complete and comprehensive selection of Fujitsu technologies and services. This takes IT flexibility and efficiency to the next level. Computing Products/global/services/computing/ - FUJITSU M10: UNIX server- PRIMERGY: Industrial standard server- PRIMEQUEST: Mission-critical IA server- ETERNUS: Storage system- BS2000/OSD: Mainframe- GS21: Mainframe- ESPRIMO: Desktop PC- LIFEBOOK: Notebook PC- CELSIUS: WorkstationSoftware/software/- Interstage: Application infrastructure- Systemwalker: System management- Symfoware: Database- PRIMECLUSTER: ClusteringMore informationLearn more about Fujitsu M10-1, pleasecontact your Fujitsu sales representative,Fujitsu business partner, or visit ourwebsite./sparcFujitsu green policy innovationFujitsu Green Policy Innovation is ourworldwide project for reducing burdens onthe environment. Using our globalknow-how, we aim to resolve issues ofenvironmental energy efficiency through IT.Please find further information at:/global/about/environment/2Copyright©Copyright 2020 Fujitsu Limited.Fujitsu, the Fujitsu logo, PRIMERGY,PRIMEQUEST, ETERNUS, BS2000/OSD, GS21,ESPRIMO, LIFEBOOK, CELSIUS, Interstage,Systemwalker, Symfoware, PRIMECLUSTERare trademarks or registered trademarks ofFujitsu Limited in Japan and other countries.GLOVIA is a trademark of GLOVIAInternational LLC in the United States andother countries.UNIX is a registered trademark of The OpenGroup in the United States and othercountries.All SPARC trademarks are trademarks orregistered trademarks of SPARCInternational, Inc. in the United States andother countries.Oracle and Java are registered trademarks ofOracle and/or its affiliates.Other company, product and service namesmay be trademarks or registeredtrademarks of their respective owners.DisclaimerTechnical data subject to modification anddelivery subject to availability. Any liabilitythat the data and illustrations are complete,actual or correct is excluded. Designationsmay be trademarks and/or copyrights of therespective manufacturer, the use of whichby third parties for their own purposes mayinfringe the rights of such owner.ContactFUJITSU LIMITED Website: 2020-09-08 WW-EN。
HUAWEI TECHNOLOGIES CO., LTD.Battery Integrated Uninterruptible Power SystemUPS5000-E (25-75 kVA) SeriesCONTENTS02 Solution Overview03 Customer Benefits09 System Architecture and Key Components12 Typical Configuration13 System Parameters14 Global Services02The three-phase uninterruptible power supply solution is applicable to small- and medium-sized data centers or high-density areas. The integrated UPS adopts online double conversion design and system with a leading efficiency up to 96%. The UPS is fully modular with hot-swappable modules. Redundancy is also supported.•UPS and batteries integrated in one cabinet •Modular and redundant•Efficient double conversion technology, systemefficiency up to 96%•High power density design• 1.0 output power factor (kVA = kW)•Front maintenance, can be installed against awall•Battery modular design•Battery module fault displayed locallyUPS5000-E Battery Integrated SolutionRated capacity: 25-75 kVASolution OverviewUPS5000-E-75K-BF03Customer Benefits:Simple · Efficient · ReliableSimple installation: Site survey and battery wiring are not required.All Modular Design01Huawei battery integrated UPS Professional installation, complexwiring, long labor hoursTraditional battery rack solutionThe power module, bypass module, battery module, and control module all use modular and integrated design. Compared with traditional UPS and battery rack solutions, the integrated UPS is installed by inserting modules onsite and does not require site survey or wiring. A common engineer can finish installation and wiring, greatly reducing labor hours for site installation and wiring.Battery Modular Pre-integration02•Batteries pre-integrated before delivery •Hot-swappable terminals •Wiring not required onsite04Simple Maintenance03Intelligent Battery Management Without Manual Inspection04Power moduleBypass moduleBattery moduleControl moduleThe power module, battery module, bypass module, and control module are all hot-swappable. Online maintenance is supported. A common engineer can finish replacement and maintenance in 5 minutes.•Battery module overtemperature alarm •Fuse blown for protection if battery module is abnormal •Fault displayed locally, easy to locate the faulty module •Intelligent equalized charging, float charging, and temperature compensation •Battery hibernation can be enabled, preventing battery lifespan from being shortened due to long-time float charging05Space Saving0125 kVA power moduleStructure patent design Heat sink designOccupying 2 U space, improve spaceuse by50%compared with theindustry>> Highly Integrated, Saving Footprint>> Power Module: High Power DensityTraditional UPS Battery rack Battery integrated UPSHuawei battery integrated solution saves50%footprint compared with a traditional solution.Customer Benefits:Simple · Efficient · ReliableThe power density increasesexponentially06Efficient and Energy-saving02•Due to redundancy configuration to ensure reliability and excessive configuration at the initial stage to meet the power demand in 3-5 years, the UPS system of traditional datacenter often operates at load rate of 10%-50% and the operating efficiency is far below the value claimed. It's estimated that the UPS loss takes up 6%-10% of the total power consumption in datacenter •H u a w e i U P S c a n k e e p h i g h efficiency operation at low load rate: Up to 96% at 40% rated load and up to 95% at 20% rated load•When the load rate is very low (below 10%-15%), intelligent hibernation can be enabled and some power modules will switch to "standby" state to boost load rate and improve operating efficiency •To ensure reliability, at least one power module serves as redundancy module and when load increases dramatically, the sleep module will be awaked instantly>> >> High efficiency at low load rate>> Intelligent hibernation design100%Load ModuleModuleModuleModuleModuleModuleModuleModule75%50%25%0%100%80%60%90%70%50%55%65%75%85%95%0%20%40%60%80%100%Load rateEfficiency07Customer Benefits:•Redundancy design for energy control unit, communication buses to eliminate single point of failure •Fault-tolerant design for fan system: 30% load can be driven when 2 fans fail and 50% load when 1 fan failsDual communication system design, single bus system failure, will not affect the normal operation of the system.Power module redundancy design, a single power module failure, will not affect the normal operation of the system.Fan fault tolerance design, Single fan faults with load 50%,two fan faults with load 30%Control moduleControl moduleCAN1CAN2CAN2CAN130% Load rate20% Load rate20% Load rate 20% Load rate 30% Load rate2 power module running3 power module running Redundant Energy Control Units08φPF=0.9(leading)PF=0.9(leading)PF=0.7(leading)PF=0.7(leading)PF=0.5(leading)PF=0.5(leading)PF=1Active power (P)Reactive power (Q)System normal operation After Airborne Hygroscopic Dust Test• 6 kV/5 kA lightning protection design, reducing lightning-related failure rateHigh load adaptability•High output power factor of up to 1, 25% more load driven than traditional UPS s The application of PFC technology in modern IT devices like servers, storages, routers improves the input power factor to more than 0.95. And if they are powered by UPS with output power factor of 0.7-0.8, the investment on UPS will increase remarkably•No derating for capacitive or inductive devices with a PF>0.5High environment adaptability•No derating at 40℃ to ensure power continuity •C o n f o r m a l c o a t i n g o n P C B , improving adaptability to dusty or salty spray environmentInput Voltage Range (V )09System Architecture and Key ComponentsSystem Architecture and Composition0125 kVA power moduleStatic bypass moduleMonitoring moduleLCD Air filterMaintenance bypass switch Input switchMonitoring unit (SNMP and RS485 communications in standard configuration)12371098854679Dimensions (H*W*D): 2000 mm x 600 mm x 1100 mm10Bypass moduleThe bypass module can provide continuous power supply to load when overload. The bypass module of UPS5000-E features concentrated design and maximum output power 128kW.Dimensions (H x W x D): 130 mm x 442 mm x 620 mmEnergy control moduleThe ECM supports intra-rack parallel CAN communication and inter-rack parallel CAN communication. The intra-rack loadshare control and inter-rack loadshare control are isolated at ECM to achieve better expandability.Battery ModuleA battery module consists of ten B.B. 9 Ah batteries. An alarm will be generated if the battery module temperature is abnormal and the fuse will be blown for protection if the battery module is abnormal. If there is a fault, the fault indicator turns on locally.Dimensions (H x W x D): 160 mm x 108 mm x 786 mmPower moduleThe Power module with rated capacity of 25 kVA/kW can eliminate all the nine common problems in public grid and output pure and stable sine wave.Dimensions (H x W x D): 86 mm x 442 mm x 620 mm11Key Components (Optional)03ComponentFunctionAntiseismic kitReinforces the cabinet so that the cabinet meets the requirements of 9 degree seismic fortification intensity.IP21 component Prevents water from dropping into the cabinet, protecting the cabinet to IP21.Battery temperature sensorFeedbacks real-time temperature and humidity data to dynamic environment monitoring system.BSC cable Transmits bus synchronization signals in a dual-bus system.>> Other Optional ComponentsBattery CabinetThe battery cabinet meets the long-time power backup requirements. Each battery cabinet can house eight battery strings (each string contains four battery modules) and is equipped with a battery switch. A maximum of four battery cabinets can be connected.Dimensions (H x W x D): 2000 mm x 600 mm x 1100 mmSystem Architecture and Key Components12Typical Configuration Configuration scene01>> Backup Time TableBattery integrated cabinetBattery cabinet3+1power modules8-16battery modules≤36battery strings≤144battery modules2-4 battery strings8 battery strings 8 battery strings 8 battery strings 8 battery stringsBattery integrated cabinet: One to three 25 kVA power modules, a maximum of four power modules can be configured with one module redundant.Battery module: One battery module contains ten B.B. 12 V 9 Ah batteries and one battery string contains four battery modules.Battery cabinet: Supports a maximum of eight battery strings, that is, 32 battery modules.25.6881612353309.944741071445.6264968885010015020025030035025kVA 50kVA 75kVABattery Integrated CabinetUnit: min2# Battery Cabinet 3# Battery Cabinet 4# Battery Cabinet1# Battery Cabinet Typical ConfigurationLong-time Power Backup ConfigurationBattery cabinetBattery cabinetBattery cabinet1. The UPS series are for commercial/industrial use and not used for life support equipment;2. The critical systems concerning economic and public security must adopt power supply architecture that comply with Uptime TIER III or TIER IV requirements stated in TIA942.1314Global ServicesHuawei has professional UPS service engineers deployed globally, providing global technical support with rapid response speed. Huawei provides customized services that include: •7*24 remote support •Software support•Active prevention •Hardware support•Onsite support •OthersLatin AmericaSoutheast AfricaSouth of South America West AfricaNorth AfricaWestern EuropeRussiaNortheast EuropeChina HeadquarterSoutheast Asia & South PacificMiddle East & Central AsiaIndia140+ countries129+ national spare parts centers 300+ regional warehousing centers 22,000+ servers 24*7 online serviceCopyright © Huawei Technologies Co., Ltd. 2018. All rights reserved.No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co., Ltd.Trademark Notice, HUAWEI, and are trademarks or registered trademarks of Huawei Technologies Co., Ltd.Other trademarks, product, service and company names mentioned are the property of their respective owners.General DisclaimerThe information in this document may contain predictive statements including, without limitation, statements regarding the future financial and operating results, future product portfolio, new technology, etc. There are a number of factorsthat could cause actual results and developments to differ materially from those expressed or implied in the predictive statements. Therefore, such informationis provided for reference purpose only and constitutes neither an offer nor an acceptance. Huawei may change the information at any time without notice.HUAWEI TECHNOLOGIES CO., LTD.Huawei Industrial BaseBantian LonggangShenzhen 518129, P.R. ChinaTel: +86-755-28780808 Version No.: M3-022334-20161215-E-2.0。
Data center optimizedThe Dell EMC Z9100-ON is a 10/25/40/50/100GbE fixed switch purpose-built for applications in high-performance data center and computing environments.Leveraging a non-blocking switching architecture, the Z9100-ON delivers line-rate L2 and L3 forwarding capacity to maximize network performance. The compact Z9100-ON design provides industry-leading density of either 32 ports of 100GbE, 64 ports of 50GbE, 32 ports of 40GbE, 128 ports of 25GbE or 128 ports 10GbE and two SFP+ ports of 10GbE/1GbE/100MbE to conserve rack space while enabling denser footprints and simplifying migration to 100Gbps in the data center core. Priority-based flow control (PFC), data center bridge exchange (DCBX) and enhanced transmission selection (ETS) make the Z9100-ON ideally suited for DCB environments. In addition, the Z9100-ON incorporatesmultiple architectural features that optimize data center network flexibility, efficiency and availability, including redundant, hot-swappable power supplies and fans.These new offerings provide the flexibility to transform data centers and offer high-capacity network fabrics that are easy to deploy, cost-effective and provide a clear path to a software-defined data center. The Dell EMC Z9100-ON supports the industry standard Open Network Install Environment (ONIE) for zero touch installation of alternate network operating systems. This document refers to this ON switch preloaded with the Dell EMC Networking OS. Characteristic of any ONIE device, other ONIE load images may be loaded by the operator.Key applications •Active Fabric™ implementation using high-density multi rate10/25/40/50/100GbE T oR server aggregation in high-performance data center environments at the desired fabric speed•Small-scale Active Fabric implementation via the Z9100-ON switch in leaf and spine along with S-Series 1/10/40GbE T oR switches enabling cost-effective aggregation of 10/40/50/100GbE uplinks• High-performance SDN/OpenFlow 1.3.1 enabled with ability to inter- operate with industry standard OpenFlow controllers•Use as a high-speed VXLAN Layer 2 Gateway that connects the hyper-visor based overlay networks with non-virtualized infrastructureKey features •1RU high-density 10/25/40/50/100GbE fixed switch with choice of up to 32 ports of 100GbE (QSFP28), 64 ports of 50GbE (QSFP+), 32 ports of 40GbE (QSFP+), 128 ports of 25GbE (SFP28) or 128+2 ports of 10GbE (using breakout cable)•Up to 6.4Tbps of switching I/O bandwidth (full duplex) available and non-blocking switching fabric delivering line-rate performance under full load with sub usec latency•Scalable L2 and L3 Ethernet switching with QoS and a fullcomplement of standards-based IPv4 and IPv6 features, including OSPF and BGP routing support• L2 multipath support via Virtual Link Trunking (VLT) and multiple VLT (mVLT) multi-chassis link aggregation technology• VRF-lite enables sharing of networking infrastructure and provides L3 traffic isolation across tenants•Open Automation Framework adding automated configuration and provisioning capabilities to simplify the management of network environments• Jumbo frame support for large data transfers• 128 link aggregation groups with up to sixteen members per group, using enhanced hashing• Redundant, hot-swappable power supplies and fans• I/O panel to power supply airflow or power supply to I/O panel airflow• Tool-less enterprise ReadyRails™ mounting kitsreducing time and resources for switch rack installation• Power-efficient operation up to 45°C helping reduce cooling costs in temperature-constrained deployments• Converged network support for DCB, with priority flow control (802.1Qbb), ETS (802.1Qaz), DCBx and iSCSI TLV support •Z9100-ON supports Routable RoCE to enable convergence of compute and storage on Active FabricDELL EMC Z9100-ON SERIES SWITCHESHigh-performance 1/10/25/40/50/100GbE multi-rate open networking fixed switchfeaturing Dell EMC Networking OS9Compact full featured fixed 10/25/40/100GEswitch1 RJ45 console/management port with RS232signaling1 10/100/1000bT Ethernet for management1 USB 2.0 type A storage port1 micro USB type B port for console/managementport access2 SFP+ 10GbE/1GbE ports for data access Size: 1 RU, 1.72”h x 17.1”w x 18”dWeight: 22 lbs (9.98 kg)Power supply: 100–240 VAC 50/60 HzMax. power consumption: 605 WattsT yp. power consumption: 195 WattsMax. operating specifications:Operating temperature: 32°F to 113°F(0°C to 45°C)Operating humidity: 10 to 90% (RH), non-condensingMax. non-operating specifications:Storage temperature: –40°F to 158°F(–40°C to 70°C)Storage humidity: 5 to 95% (RH), non-condensingFresh Air Compliant to 45°CReadyRails rack mounting system, no tools required RedundancyT wo hot swappable power supplies with integratedfansHot swappable redundant fansPerformanceSwitching I/O bandwidth: 6.4Tbps (Full Duplex) Forwarding capacity: Up to 3300 MppsMAC addresses: 136KIPv4 Unicast routes: 136KIPv6 Unicast routes: 68KIPv4 Multicast routes: 68KIPv6 Multicast routes: Not supportedMulticast Hosts: 8KARP entries: 128KLayer 2 VLANs: 4K per portLayer 3 VLANs: Standalone 1K/VLT 4KMST: 64 instancesPVST+: 128 instancesLAG: 128 groups, 16 members per LAG groupLAG load balancing:Based on layer 2, IPv4 or IPv6 headers Latency: Sub 500nsPacket buffer memory: 16MBCPU memory: 8GBQOS data queues: 8QOS control queues: 12QOS: Default 1024 entries scalable to 2.5KACL Support: 3KIEEE compliance802.1AB LLDP802.1D Bridging, STP802.1p L2 Prioritization802.1Q VLAN T agging, Double VLAN T agging,GVRP802.1Qbb PFC802.1Qaz ETS802.1s MSTP 802.1X Network Access Control802.3ab Gigabit Ethernet (1000BASE-T) orbreakout802.3ac Frame Extensions for VLAN T agging802.3ad Link Aggregation with LACP802.3ae 10 Gigabit Ethernet (10GBase-X)802.3ba 40 Gigabit Ethernet (40GBase-SR4,40GBase-CR4, 40GBase-LR4, 100GBase-SR10,100GBase-LR4, 100GBase-ER4) on optical ports802.3bj 100 Gigabit Ethernet802.3u Fast Ethernet (100Base-TX) on mgmtports802.3x Flow Control802.3z Gigabit Ethernet (1000Base-X) with QSAANSI/TIA-1057 LLDP-MEDForce10 PVST+Jumbo MTU support 9,416 bytesRFC and I-D complianceGeneral Internet protocols768 UDP793 TCP854 Telnet959 FTPGeneral IPv4 protocols791 IPv4792 ICMP826 ARP1027 Proxy ARP1035 DNS (client)1042 Ethernet Transmission1305 NTPv31519 CIDR1542 BOOTP (relay)1812 Requirements for IPv4 Routers1918 Address Allocation for Private Internets2474 Diffserv Field in IPv4 and Ipv6 Headers2596 Assured Forwarding PHB Group3164 BSD Syslog3195 Reliable Delivery for Syslog3246 Expedited Assured Forwarding4364 VRF-lite (IPv4 VRF with OSPF and BGP)5798 VRRPGeneral IPv6 protocols1981 Path MTU Discovery Features2460 Internet Protocol, Version 6 (IPv6)Specification2464 Transmission of IPv6 Packets over EthernetNetworks2711 IPv6 Router Alert Option4007 IPv6 Scoped Address Architecture4213 Basic Transition Mechanisms for IPv6 Hostsand Routers4291 IPv6 Addressing Architecture4443 ICMP for IPv64861 Neighbor Discovery for IPv64862 IPv6 Stateless Address Autoconfiguration5095 Deprecation of Type 0 Routing Headers inIPv6IPv6 Management support (telnet, FTP, TACACS,RADIUS, SSH, NTP)Security2404 The Use of HMACSHA-1-96 within ESP andAH2865 RADIUS3162 Radius and IPv63580 802.1X with RADIUS3768 EAP3826 AES Cipher Algorithm in the SNMP UserBase Security Model4250, 4251, 4252, 4253, 4254 SSHv24301 Security Architecture for IPSec4302 IPSec Authentication Header4303 ESP Protocol4807 IPsec Security Policy DB MIBRIP1058 RIPv12453 RIPv2OSPF (v2/v3)1587 NSSA 4552 Authentication/2154 OSPF Digital Signatures Confidentiality for2328 OSPFv2 OSPFv32370 Opaque LSA 5340 OSPF for IPv6ISIS5301 Dynamic hostname exchange mechanism forIS-IS5302 Domain-wide prefix distribution with two-levelIS-IS5303 Three way handshake for IS-IS point-to-point adjacencies5308 IS-IS for IPv6BGP1997 Communities2385 MD52545 BGP-4 Multiprotocol Extensions for IPv6Inter-Domain Routing2439 Route Flap Damping2796 Route Reflection2842 Capabilities2858 Multiprotocol Extensions2918 Route Refresh3065 Confederations4360 Extended Communities4893 4-byte ASN5396 4-byte ASN representationsdraft-ietf-idr-bgp4-20 BGPv4draft-michaelson-4byte-as-representation-054-byte ASN Representation (partial)draft-ietf-idr-add-paths-04.txt ADD PATHMulticast1112 IGMPv12236 IGMPv23376 IGMPv3MSDPPIM-SMPIM-SSMData center bridging802.1Qbb Priority-Based Flow Control802.1Qaz Enhanced Transmission Selection (ETS)Data Center Bridging eXchange (DCBx)DCBx Application TLV (iSCSI, FCoE)Network management1155 SMIv11157 SNMPv11212 Concise MIB Definitions1215 SNMP Traps1493 Bridges MIB1850 OSPFv2 MIB1901 Community-Based SNMPv22011 IP MIB2096 IP Forwarding T able MIB2578 SMIv22579 T extual Conventions for SMIv22580 Conformance Statements for SMIv22618 RADIUS Authentication MIB2665 Ethernet-Like Interfaces MIB2674 Extended Bridge MIB2787 VRRP MIB2819 RMON MIB (groups 1, 2, 3, 9)2863 Interfaces MIB3273 RMON High Capacity MIB3410 SNMPv33411 SNMPv3 Management Framework3412 Message Processing and Dispatching for the Simple Network Management Protocol(SNMP)3413 SNMP Applications3414 User-based Security Model (USM) for SNMPv33415 VACM for SNMP3416 SNMPv23417 Transport mappings for SNMP3418 SNMP MIB3434 RMON High Capacity Alarm MIB3584 Coexistance between SNMP v1, v2 and v3 4022 IP MIB4087 IP Tunnel MIB4113 UDP MIB4133 Entity MIB4292 MIB for IP4293 MIB for IPv6 Textual Conventions4502 RMONv2 (groups 1,2,3,9)5060 PIM MIBANSI/TIA-1057 LLDP-MED MIBDell_ITA.Rev_1_1 MIBdraft-grant-tacacs-02 TACACS+draft-ietf-idr-bgp4-mib-06 BGP MIBv1IEEE 802.1AB LLDP MIBIEEE 802.1AB LLDP DOT1 MIBIEEE 802.1AB LLDP DOT3 MIB sFlowv5 sFlowv5 MIB (version 1.3)FORCE10-BGP4-V2-MIB Force10 BGP MIB (draft-ietf-idr-bgp4-mibv2-05)FORCE10-IF-EXTENSION-MIBFORCE10-LINKAGG-MIBFORCE10-COPY-CONFIG-MIBFORCE10-PRODUCTS-MIBFORCE10-SS-CHASSIS-MIBFORCE10-SMIFORCE10-TC-MIBFORCE10-TRAP-ALARM-MIBFORCE10-FORWARDINGPLANE-STATS-MIB Regulatory complianceSafetyUL/CSA 60950-1, Second EditionEN 60950-1, Second EditionIEC 60950-1, Second Edition Including All National Deviations and Group DifferencesEN 60825-1 Safety of Laser Products Part 1: Equipment Classification Requirements andUser’s GuideEN 60825-2 Safety of Laser Products Part 2: Safety of Optical Fibre Communication Systems FDA Regulation 21 CFR 1040.10 and 1040.11 EmissionsAustralia/New Zealand: AS/NZS CISPR 22: 2006, Class ACanada: ICES-003, Issue-4, Class AEurope: EN 55022: 2006+A1:2007 (CISPR 22: 2006), Class AJapan: VCCI V3/2009 Class AUSA: FCC CFR 47 Part 15, Subpart B:2011, Class A ImmunityEN 300 386 V1.4.1:2008 EMC for NetworkEquipmentEN 55024: 1998 + A1: 2001 + A2: 2003EN 61000-3-2: Harmonic Current EmissionsEN 61000-3-3: Voltage Fluctuations and Flicker EN 61000-4-2: ESDEN 61000-4-3: Radiated ImmunityEN 61000-4-4: EFTEN 61000-4-5: SurgeEN 61000-4-6: Low Frequency ConductedImmunityRoHSAll S Series components are EU RoHS compliant. CertificationsAvailable with US Trade Agreements Act (TAA)complianceUSGv6 Host and Router Certified on Dell Networking OS 9.5 and greaterIPv6 Ready for both Host and RouterUCR DoD APL (core and distribution ALSAN switch Warranty1 year return to depotLearn more at DellT /Networking。