MT产品培训手册--梅特勒-托利多
- 格式:pdf
- 大小:3.12 MB
- 文档页数:68
操作手册多参数变送器 M300多参数变送器 M300如有技术变更,恕不另行通知。
© 02/2016 Mettler-Toledo GmbH, Process Analytics, Switzerland30 216 266. Printed in Switzerland操作手册多参数变送器 M300目录1 简介 _________________________________________________________________________________________________92 安全须知 ____________________________________________________________________________________________102.1 设备定义和文件中使用的符号与标志 ______________________________________________________________102.2 装置的妥善处置 _______________________________________________________________________________113 装置概述 ____________________________________________________________________________________________123.1 M300 1/2 DIN 型号 ______________________________________________________________________________123.2 M300 1/4 DIN 型号 ______________________________________________________________________________133.3 菜单结构 ______________________________________________________________________________________143.4 显示屏 ________________________________________________________________________________________153.5 操作单元 ______________________________________________________________________________________163.6 数据输入 ______________________________________________________________________________________163.7 选择菜单 ______________________________________________________________________________________163.8 “保存更改内容”对话框 ________________________________________________________________________173.9 安全密码 ______________________________________________________________________________________173.10 测量图形曲线 __________________________________________________________________________________173.10.1 激活曲线显示界面 ______________________________________________________________________173.10.2 曲线显示界面的设置 ____________________________________________________________________183.10.3 关闭曲线显示界面 ______________________________________________________________________184 安装说明 ____________________________________________________________________________________________194.1 开箱及设备检验 ________________________________________________________________________________194.2 安装 1/2 DIN 型号_______________________________________________________________________________194.2.1 1/2 DIN 型号的尺寸______________________________________________________________________194.2.2 安装流程 – 1/2 DIN 型号 _________________________________________________________________204.2.3 1/2 DIN – 面板安装 ______________________________________________________________________214.2.4 1/2 DIN 型 – 墙壁安装 ___________________________________________________________________224.2.5 1/2 DIN 型 – 管道安装 ___________________________________________________________________234.3 安装 1/4 DIN 型号_______________________________________________________________________________244.3.1 1/4 DIN 型号的尺寸______________________________________________________________________244.3.2 安装过程 – 1/4 DIN 型号 _________________________________________________________________254.4 电气连接 ______________________________________________________________________________________264.5 端子定义 ______________________________________________________________________________________274.5.1 TB1端子定义 – 所有变送器型号___________________________________________________________28端子排定义(单通道和双通道型号)___________________________________________________284.5.2 TB24.5.3 TB2、TB2A 和 TB2B 端子定义 – 单通道型号 _________________________________________________294.5.4 电导率 2-e 和电导率 4-e 的 TB3 和 TB4 端子定义 – 模拟传感器 ________________________________29的 TB3 和 TB4 端子定义 – 模拟传感器 _______________________________________________304.5.5 pH/ORP4.5.6 电化学溶氧和溶解臭氧的 TB3 和 TB4 端子定义 – 模拟传感器 __________________________________314.5.7 pH/ORP、电化学溶氧、溶解臭氧和电导率 4-e 的 TB3 和 TB4 端子定义 – ISM 传感器 ______________314.5.8 UniCond 2-e 和 UniCond 4-e 的 TB3 和 TB4 端子定义 – ISM 传感器 _______________________________325 变送器投入使用或停止使用____________________________________________________________________________335.1 变送器投入使用 ________________________________________________________________________________335.2 变送器停止使用 _______________________________________________________________________________336 校准 ________________________________________________________________________________________________346.1 传感器校准 ____________________________________________________________________________________346.1.1 选择通道 ______________________________________________________________________________346.1.2 选择所需的传感器校准任务 ______________________________________________________________346.1.3 终止传感器校准 ________________________________________________________________________356.2 UniCond 2-e 和 UniCond 4-e 传感器的校准(仅限 ISM 传感器) ________________________________________356.2.1 UniCond 2-e 和 UniCond 4-e 传感器的电导率校准 _____________________________________________356.2.1.1 单点校准 ____________________________________________________________________376.2.1.2 两点校准 ____________________________________________________________________386.2.1.3 过程校准 ____________________________________________________________________396.2.2 UniCond 2-e 和 UniCond 4-e 传感器的温度校准 _______________________________________________406.2.2.1 单点校准 ____________________________________________________________________406.2.2.2 两点校准 ____________________________________________________________________41或 Cond4e 传感器的校准 __________________________________________________________________436.3 Cond2e6.3.1 单点校准 ______________________________________________________________________________436.3.2 两点校准 ______________________________________________________________________________446.3.3 过程校准 ______________________________________________________________________________446.4.2 两点校准 ______________________________________________________________________________466.4.3 过程校准 ______________________________________________________________________________46传感器的 ORP 校准___________________________________________________________________________476.5 pH6.6 电化学氧传感器的校准 __________________________________________________________________________486.6.1 单点校准 ______________________________________________________________________________486.6.2 过程校准 ______________________________________________________________________________496.7 臭氧传感器的校准 ______________________________________________________________________________496.7.1 单点校准 ______________________________________________________________________________506.7.2 过程校准 ______________________________________________________________________________516.8 传感器验证 ____________________________________________________________________________________526.9 UniCond 2-e 电子线路校准(仅限 ISM 传感器) _____________________________________________________526.10 仪表校准(仅限模拟传感器) ____________________________________________________________________536.10.1 电阻(仅限模拟传感器) ________________________________________________________________536.10.2 温度(仅限模拟传感器) ________________________________________________________________546.10.3 电压(仅限模拟传感器) ________________________________________________________________556.10.4 电流(仅限模拟传感器) ________________________________________________________________566.10.5 玻璃传感器膜阻抗 (Rg)(仅限模拟传感器) ________________________________________________566.10.6 Rr(仅限模拟传感器)___________________________________________________________________566.11 模拟输出校准 __________________________________________________________________________________576.12 维护 __________________________________________________________________________________________577 配置 ________________________________________________________________________________________________587.1 测量 __________________________________________________________________________________________587.1.1 通道设定 ______________________________________________________________________________587.1.2 模拟传感器 ____________________________________________________________________________587.1.3 ISM传感器 _____________________________________________________________________________597.1.4 派生测量 ______________________________________________________________________________607.1.4.1 脱盐率测量 ___________________________________________________________________607.1.4.2 计算 pH 值(仅限电厂应用)____________________________________________________607.1.5 显示模式 ______________________________________________________________________________617.1.6 相关参数设置 __________________________________________________________________________617.1.6.1 电导率设置 ___________________________________________________________________62设置 ______________________________________________________________________637.1.6.2 pH7.1.6.3 电化学氧传感器的测量设置 _____________________________________________________647.2 温度源(仅限模拟传感器) ______________________________________________________________________657.3 模拟输出 ______________________________________________________________________________________657.4 设定点 ________________________________________________________________________________________66设定(仅限 ISM 传感器) ____________________________________________________________________677.5 ISM7.5.1 传感器监测 ____________________________________________________________________________677.5.2 最大 CIP 次数___________________________________________________________________________697.5.3 最大 SIP 次数___________________________________________________________________________697.5.4 最大高压锅灭菌次数 ____________________________________________________________________70负荷调节 ___________________________________________________________________________717.5.5 DLI周期参数___________________________________________________________________________717.5.6 SAN7.5.7 复位 UniCond 2-e 传感器的计数器 _________________________________________________________727.5.8 设置 UniCond 2-e 传感器的校准间隔 _______________________________________________________727.6 常规报警 ______________________________________________________________________________________727.7 ISM / 传感器报警 _______________________________________________________________________________737.8 清洗 __________________________________________________________________________________________737.9 显示器设置 ____________________________________________________________________________________747.10 数字输入 ______________________________________________________________________________________747.11 系统 __________________________________________________________________________________________757.12 PID 控制器_____________________________________________________________________________________767.13 服务 __________________________________________________________________________________________807.13.1 设置模拟输出 __________________________________________________________________________807.13.2 读取模拟输出 __________________________________________________________________________807.13.3 设置继电器 ____________________________________________________________________________807.13.4 读取继电器 ____________________________________________________________________________807.13.5 读取数字输入 __________________________________________________________________________807.13.6 内存 __________________________________________________________________________________817.13.7 显示屏 ________________________________________________________________________________817.13.8 校准触摸屏 ____________________________________________________________________________817.13.9 通道诊断 ______________________________________________________________________________817.14 用户管理 ______________________________________________________________________________________827.15.2 重设 UniCond 2-e 传感器的校准 ___________________________________________________________837.16 USB 输出 ______________________________________________________________________________________837.16.1 打印机输出设置 ________________________________________________________________________848 ISM _________________________________________________________________________________________________858.1 智能监测 (iMonitor) _____________________________________________________________________________858.2 信息 __________________________________________________________________________________________86诊断 ______________________________________________________________________________________868.3 ISM8.3.1 pH/ORP、氧、臭氧和 Cond4e 传感器 _______________________________________________________878.3.2 UniCond 2-e 和 UniCond 4-e 传感器 _________________________________________________________878.4 校准数据 ______________________________________________________________________________________888.4.1 UniCond 2-e 和 UniCond 4-e 以外的所有 ISM 传感器的校准数据 _________________________________888.4.2 UniCond 2-e 和 UniCond 4-e 传感器的校准数据 _______________________________________________898.5 传感器信息 ____________________________________________________________________________________898.6 硬件/软件版本 _________________________________________________________________________________909 收藏菜单 ____________________________________________________________________________________________919.1 设置收藏菜单 __________________________________________________________________________________919.2 访问收藏菜单 __________________________________________________________________________________9110 维护 ________________________________________________________________________________________________9210.1 前板清洁 ______________________________________________________________________________________9211 软件历史 ____________________________________________________________________________________________9211.1 M300 Process __________________________________________________________________________________9211.2 M300 Water ____________________________________________________________________________________9211.3 M300 Water Cond/Res ____________________________________________________________________________9212 故障排除 ____________________________________________________________________________________________9312.1 用于模拟传感器的电导率(电阻)错误信息 / 警告与警报列表 _________________________________________9312.2 用于 ISM 传感器的电导率(电阻率)错误信息 /警告和警报列表 ______________________________________________________________________________________9412.3 pH 错误信息/警告—以及警报列表 _______________________________________________________________9412.3.1 pH 传感器,双膜 pH 电极除外 ____________________________________________________________9412.3.2 双膜 pH 电极 (pH / pNa) _________________________________________________________________9512.3.3 ORP 消息 ______________________________________________________________________________9512.4 电化学氧错误信息 / 警告与警报列表 ______________________________________________________________9612.4.1 高氧传感器 ____________________________________________________________________________9612.4.2 低氧传感器 ____________________________________________________________________________9612.5 警告和警报指示 ________________________________________________________________________________9712.5.1 警告指示 ______________________________________________________________________________9712.5.2 警报指示 ______________________________________________________________________________9813 订购信息、附件和备件 ________________________________________________________________________________9914 技术参数 ___________________________________________________________________________________________10014.1 常规规格 _____________________________________________________________________________________10014.2 电气规格 _____________________________________________________________________________________10214.3 环境规格 _____________________________________________________________________________________10214.4 机械规范 _____________________________________________________________________________________10315 质保 _______________________________________________________________________________________________10416 缓冲液表 ___________________________________________________________________________________________10516.1 标准 pH 缓冲液________________________________________________________________________________10516.1.1 Mettler-9 _______________________________________________________________________________10516.1.2 Mettler-10 _____________________________________________________________________________10616.1.3 NIST 技术型缓冲液 _____________________________________________________________________10616.1.4 NIST 标准缓冲液 (DIN 19266: 2000–01) ___________________________________________________10716.1.5 Hach 缓冲液___________________________________________________________________________10716.1.6 Ciba (94) 缓冲液 _______________________________________________________________________10816.1.7 Merck Titrisole、Riedel-de-Haën Fixanale ____________________________________________________10816.1.8 WTW 缓冲液___________________________________________________________________________10916.1.9 JIS Z 8802 缓冲液 ______________________________________________________________________10916.2 双膜 pH 电极缓冲液____________________________________________________________________________11016.2.1 Mettler-pH/pNa 缓冲液 (Na+ 3.9M) ________________________________________________________1101 简介用途声明 – M300 是一款用于分析测量的 4 线制变送器,提供 4 (0) 至 20 mA 的输出信号。
用户指南APR430热敏标签打印机APR430 热敏标签打印机确保 APR430Thermal Label Printer性能可靠的必要服务恭喜您选择以质量和精度著称的梅特勒托利多产品。
按照本手册正确使用新设备,并由我们的工厂培训过的服务团队进行定期校准和维护,可确保可靠、准确的操作,保护您的投资。
请联系我们,我们将按照您的需求和预算为您定制专有的服务协议。
请访问/service了解更多信息。
可通过多种重要方法来确保最大限度地提高投资绩效:1.注册您的产品:我们邀请您在/productregistration注册您的产品,以便我们可在出现有关您的产品的增强、更新和重要通知时与您联系。
2.联系梅特勒托利多获取服务:测量的价值与其准确性成正比 — 不合格的秤会降低质量、减少利润并增加责任。
梅特勒托利多的及时服务将确保准确度,并优化正常运行时间和设备的使用寿命。
安装、配置、集成和培训:我们的服务代表是经工厂培训的称重设备专家。
我们确保您的称重设备能够以经济高效且及时的方式随时准备用于生产,且人员经过培训以获得成功。
© 梅特勒托利多 2022未经梅特勒托利多明确书面许可,不得以任何形式或任何方式(电子或机械),出于任何目的对本手册的任一部分进行复制或传播,包括复印和录制。
美国政府限制权利:本文件按限制权限提供。
版权所有 2022 梅特勒托利多。
本文档中包含梅特勒托利多专有信息。
未经梅特勒托利多明确书面同意,不得复制全部或部分。
版权梅特勒托利多®是梅特勒托利多的注册商标。
所有其他品牌或产品名均为其各自公司的商标或注册商标。
梅特勒托利多保留改进或更改的权利,恕不另行通知。
安全须知务必按照本手册的要求使用设备。
如果您未能遵照这些文档使用本设备,或者对本设备进行改动,则可能会损害本设备的安全,梅特勒托利多公司对此不承担任何责任。
一般预防措施•按照本手册的要求使用本设备。
•本设备只能在室内使用。
梅特勒_托利多MTB称重传感器参考资料梅特勒托利多称重传感器尺寸图瑞士METTLER TOLEDO梅特勒托利多称重传感器类型TSC/TSB拉式S型称重传感器产品型号产品描述TSC-50 钢质拉式传感器,容量50KG,5M电缆TSC-100 钢质拉式传感器,容量100KG,5M电缆TSC-200 钢质拉式传感器,容量200KG,5M电缆TSC-300 钢质拉式传感器,容量300KG,5M电缆TSC-500 钢质拉式传感器,容量500KG,5M电缆TSC-1000 钢质拉式传感器,容量1000KG,5M电缆TSB-2000 钢质拉式传感器,容量2000KG,5M电缆TSB-2000 钢质拉式传感器,容量2000KG,12M电缆TSB-3000 钢质拉式传感器,容量3000KG,5M电缆TSB-3000 钢质拉式传感器,容量3000KG,12M电缆TSB-5000 钢质拉式传感器,容量5000KG,5M电缆TSB-5000 钢质拉式传感器,容量5000KG,12M电缆拉式称重传感器连接件产品型号产品描述TP-100~300 配100~300KG TSC,拉杆式TP-500~1000 配500~1000KG TSC,拉杆式ZP-100~300 配100~300KG TSC,关节轴承式ZP-500~1000 配500~1000KG TSC,关节轴承式ZP-2000 配2000KG TSB,关节轴承式ZP-3000 配3000KG TSB,关节轴承式ZP-5000 配5000KG TSB,关节轴承式SB系列剪切梁传感器产品型号产品描述SB-0.3 剪切梁传感器,容量0.3T,盲孔,4M电缆SB-0.5t 剪切梁传感器,容量0.5T,盲孔,4M电缆SB-0.5t 剪切梁传感器,容量0.5T,盲孔,12M电缆SB-1t 剪切梁传感器,容量1T,盲孔,4M电缆SB-1t 剪切梁传感器,容量1T,盲孔,12M电缆SB-2t 剪切梁传感器,容量2T,盲孔,4M电缆SB-2t 剪切梁传感器,容量2T,盲孔,12M电缆SB-3t 剪切梁传感器,容量3T,盲孔,4M电缆SB-5t 剪切梁传感器,容量5T,盲孔孔,5M电缆SB-10t 剪切梁传感器,容量10T,盲孔孔,6M电缆SB-15t 剪切梁传感器,容量15T,盲孔孔,10M电缆SB-20t 剪切梁传感器,容量20T,盲孔孔,10M电缆SBT系列剪切梁传感器产品型号产品描述SBT-0.3t 剪切梁传感器,容量0.3T,通孔,4M电缆SBT-0.5t 剪切梁传感器,容量0.5T,通孔,4M电缆SBT-1t 剪切梁传感器,容量1T,通孔,4M电缆SBT-2t 剪切梁传感器,容量2T,通孔,4M电缆SBT-3t 剪切梁传感器,容量3T,通孔,4M电缆SBT-5t 剪切梁传感器,容量5T,通孔,5M电缆SBS系列剪切梁传感器产品型号产品描述SBS-0.3t 剪切梁传感器,容量0.3T,螺纹孔,4M电缆SBS-0.5t 剪切梁传感器,容量0.5T,螺纹孔,4M电缆SBS-1t 剪切梁传感器,容量1T,螺纹孔,4M电缆SBS-2t 剪切梁传感器,容量2T,螺纹孔,4M电缆SBS-3t 剪切梁传感器,容量3T,螺纹孔,4M电缆SBC系列紧密型剪切梁称重传感器及其连接件产品型号产品描述SBC-0.5t 紧密型剪切梁传感器,容量0.5T,3M电缆SBC-0.5t 紧密型剪切梁传感器,容量0.5T,6M电缆SBC-1t 紧密型剪切梁传感器,容量1T,3M电缆SBC-1t 紧密型剪切梁传感器,容量1T,6M电缆SBC-2t 紧密型剪切梁传感器,容量2T,3M电缆SBC-2t 紧密型剪切梁传感器,容量2T,6M电缆SBC-3t 紧密型剪切梁传感器,容量3T,3M电缆SBC-3t 紧密型剪切梁传感器,容量3T,6M电缆连接件SPC-0.5~3T 紧密型剪切梁称重传感器专用连接件SPC-5T 紧密型剪切梁称重传感器专用连接件SBH系列不锈钢焊接密封传感器产品型号产品描述SBH-0.25t 弯曲梁称重传感器,称重容量0.25T,5M电缆SBH-0.5t 弯曲梁称重传感器,称重容量0.5T,5M电缆SBH-1t 弯曲梁称重传感器,称重容量1T,5M电缆SBH-2t 弯曲梁称重传感器,称重容量2T,5M电缆SBH-3t 弯曲梁称重传感器,称重容量3T,5M电缆SBH-5 弯曲梁称重传感器,称重容量5T,5M电缆IL系列称重传感器产品型号产品描述IL-150KG 钢质弯曲梁传感器,容量150KG,2.5M电缆IL-250KG 钢质弯曲梁传感器,容量250KG,2.5M电缆IL-500KG 钢质弯曲梁传感器,容量500KG,2.5M电缆IL-1000KG 钢质弯曲梁传感器,容量1000KG,2.5M电缆IL-2000KG 钢质弯曲梁传感器,容量2000KG,2.5M电缆0745A/0743系列不锈钢焊接密封传感器产品型号产品描述0745A-0.22t 0745A称重传感器0.22T,2.2M电缆0745A-0.22t 0745A称重传感器0.22T,4.5M电缆0745A-0.22t 0745A称重传感器0.22T,9M电缆0745A-0.55t 0745A称重传感器0.55T,2.2M电缆0745A-0.55t 0745A称重传感器0.55T,4.5M电缆0745A-0.55t 0745A称重传感器0.55T,9M电缆0745A-1.1t 0745A称重传感器1.1T,2.2M电缆0745A-1.1t 0745A称重传感器1.1T,4.5M电缆0745A-1.1t 0745A称重传感器1.1T,9M电缆0745A-2.2t 0745A称重传感器2.2T,2.2M电缆0745A-2.2t 0745A称重传感器2.2T,4.5M电缆0745A-2.2t 0745A称重传感器2.2T,9M电缆0745A-4.4t 0745A称重传感器4.4T,4.5M电缆0745A-4.4t 0745A称重传感器4.4T,9M电缆0745A-4.4t 0745A称重传感器4.4T,18M电缆GD柱式称重传感器产品型号产品描述GD-15 柱式GD不锈钢称重传感器,容量15t,13M电缆GD-20 柱式GD不锈钢称重传感器,容量20t,13M电缆GD-30 柱式GD不锈钢称重传感器,容量30t,13M电缆GD-50 柱式GD不锈钢称重传感器,容量50t,13M电缆GD-100 柱式GD不锈钢称重传感器,容量100t,13M电缆GD柱式防爆传感器产品型号产品描述GD-15x 柱式GD不锈钢称重传感器,容量15t,13M电缆GD-20x 柱式GD不锈钢称重传感器,容量20t,13M电缆GD-30x 柱式GD不锈钢称重传感器,容量30t,13M电缆GD-50x 柱式GD不锈钢称重传感器,容量50t,13M电缆GD-100x 柱式GD不锈钢称重传感器,容量100t,13M电缆电流型模拟量输出传感器产品型号产品描述GD-15-AOC GD电流型模拟量输出传感器,容量15T,13M电缆GD-20-AOC GD电流型模拟量输出传感器,容量20T,13M电缆GD-30-AOC GD电流型模拟量输出传感器,容量30T,13M电缆GD-50-AOC GD电流型模拟量输出传感器,容量50T,13M电缆GD-100-AOC GD电流型模拟量输出传感器,容量100T,13M电缆GD-200-AOC GD电流型模拟量输出传感器,容量200T,20M电缆GD-250-AOC GD电流型模拟量输出传感器,容量250T,20M电缆GD-300-AOC GD电流型模拟量输出传感器,容量300T,30M电缆GD-400-AOC GD电流型模拟量输出传感器,容量400T,30M电缆GD-500-AOC GD电流型模拟量输出传感器,容量500T,30M电缆PGD-2-AOC GD电流型模拟量输出传感器,容量2T,13M电缆PGD-5-AOC GD电流型模拟量输出传感器,容量5T,13M电缆PGD-10-AOC GD电流型模拟量输出传感器,容量10T,13M电缆PGD-20-AOC GD电流型模拟量输出传感器,容量20T,13M电缆PGD-30-AOC GD电流型模拟量输出传感器,容量30T,13M电缆PGD-50-AOC GD电流型模拟量输出传感器,容量50T,13M电缆选配件(用于隔离电源及信号)3042隔离安全栅3042隔离安全栅屏蔽电缆瑞士METTLER TOLEDO梅特勒托利多称重模块类型FW/CW系列称重模块产品型号产品描述FW-0.3t 固定式静载模块,容量0.3t,4M电缆FW-0.3t 半浮动式静载模块,容量0.3t,4M电缆FW-0.3t 全浮动式静载模块,容量0.3t,4M电缆FW-0.5t 固定式载模块,容量0.5t,4M电缆FW-0.5t 半浮动式静载模块,容量0.5t,4M电缆FW-0.5t 全浮动式静载模块,容量0.5t,4M电缆FW-1t 固定式静载模块,容量1t,4M电缆FW-1t 固定式静载模块,容量1t,12M电缆FW-1t 半浮动式静载模块,容量1t,4M电缆FW-1t 半浮动式静载模块,容量1t,12M电缆FW-1t 全浮动式静载模块,容量1t,4M电缆FW-1t 全浮动式静载模块,容量1t,12M电缆FW-2t 固定式静载模块,容量2t,4M电缆FW-2t 固定式静载模块,容量2t,12M电缆FW-2t 半浮动式静载模块,容量2t,4M电缆FW-2t 半浮动式静载模块,容量2t,12M电缆FW-2t 全浮动式静载模块,容量2t,4M电缆FW-2t 全浮动式静载模块,容量2t,12M电缆FW-3t 固定式静载模块,容量3t,4M电缆FW-3t 半浮动式静载模块,容量3t,4M电缆FW-3t 全浮动式静载模块,容量3t,4M电缆FW-5t 固定式静载模块,容量5t,5M电缆FW-5t 半浮动式静载模块,容量5t,5M电缆FW-5t 全浮动式静载模块,容量5t,5M电缆FW-10t 固定式静载模块,容量10t,6M电缆FW-10t 半浮动式静载模块,容量10t,6M电缆FW-10t 全浮动式静载模块,容量10t,6M电缆FW-15t 固定式静载模块,容量15t,10M电缆FW-15t 半浮动式静载模块,容量15t,10M电缆FW-15t 全浮动式静载模块,容量15t,10M电缆FW-20t 固定式静载模块,容量20t,10M电缆FW-20t 半浮动式静载模块,容量20t,10M电缆FW-20t 全浮动式静载模块,容量20t,10M电缆CW-0.3t 动载模块,容量0.3t,4M电缆CW-0.5t 动载模块,容量0.5t,4M电缆CW-1t 动载模块,容量1t,4M电缆CW-2t 动载模块,容量2t,4M电缆CW-3t 动载模块,容量3t,4M电缆CW-5t 动载模块,容量5t,5M电缆CW-10t 动载模块,容量10t,6M电缆CW-15t 动载模块,容量15t,10M电缆CW-20t 动载模块,容量20t,10M电缆FWC/CWC系列称重模块产品型号产品描述FWC-0.22x 防爆固定式不锈钢静载模块,容量0.22t,4.5M电缆FWC-0.22x 防爆浮动式不锈钢静载模块,容量0.22t,4.5M电缆FWC-0.22x 防爆半防爆浮动式不锈钢静载模块,容量0.22t,4.5M电缆FWC-0.55x 防爆固定式不锈钢静载模块,容量0.55t,4.5M电缆FWC-0.55x 防爆浮动式不锈钢静载模块,容量0.55t,4.5M电缆FWC-0.55x 防爆半防爆浮动式不锈钢静载模块,容量0.55t,4.5M电缆FWC-1.1x 防爆固定式不锈钢静载模块,容量1.1t,4.5M电缆FWC-1.1x 防爆浮动式不锈钢静载模块,容量1.1t,4.5M电缆FWC-1.1x 防爆半防爆浮动式不锈钢静载模块,容量1.1t,4.5M电缆FWC-2.2x 防爆固定式不锈钢静载模块,容量2.2t,4.5M电缆FWC-2.2x 防爆浮动式不锈钢静载模块,容量2.2t,4.5M电缆FWC-2.2x 防爆半防爆浮动式不锈钢静载模块,容量2.2t,4.5M电缆FWC-4.4x 防爆固定式不锈钢静载模块,容量4.4t,4.5M电缆FWC-4.4x 防爆浮动式不锈钢静载模块,容量4.4t,4.5M电缆FWC-4.4x 防爆半防爆浮动式不锈钢静载模块,容量4.4t,4.5M电缆FWC-9x 防爆固定式不锈钢静载模块,容量9t,9M电缆FWC-9x 防爆浮动式不锈钢静载模块,容量9t,9M电缆FWC-9x 防爆半防爆浮动式不锈钢静载模块,容量9t,9M电缆FWC-13.6x 防爆固定式不锈钢静载模块,容量13.6t,9M电缆FWC-13.6x 防爆浮动式不锈钢静载模块,容量13.6t,9M电缆FWC-13.6x 防爆半防爆浮动式不锈钢静载模块,容量13.6t,9M电缆FWC-20x 防爆固定式不锈钢静载模块,容量20t,9M电缆FWC-20x 防爆浮动式不锈钢静载模块,容量20t,9M电缆FWC-20x 防爆半防爆浮动式不锈钢静载模块,容量20t,9M电缆CWC-0.22x 不锈钢动载模块,容量0.22t,4.5M电缆CWC-0.55x 不锈钢动载模块,容量0.55t,4.5M电缆CWC-1.1x 不锈钢动载模块,容量1.1t,4.5M电缆CWC-2.2x 不锈钢动载模块,容量2.2t,4.5M电缆CWC-4.4x 不锈钢动载模块,容量4.4t,4.5M电缆CWC-9x 不锈钢动载模块,容量9t,9M电缆CWC-13.6x 不锈钢动载模块,容量13.6t,9M电缆CWC-20x 不锈钢动载模块,容量20t,9M电缆GW/UW/PGW/GWA/PGWA-X模块产品型号产品描述GW-15x 防爆GW不锈钢称重模块,容量15t,,13M电缆GW-20x 防爆GW不锈钢称重模块,容量20t,,13M电缆GW-30x 防爆GW不锈钢称重模块,容量30t,,13M电缆GW-50x 防爆GW不锈钢称重模块,容量50t,,13M电缆GW-100x 防爆GW不锈钢称重模块,容量100t,,13M电缆GW-200x 防爆GW不锈钢称重模块,容量200t,,20M电缆GW-250x 防爆GW不锈钢称重模块,容量250t,,20M电缆GW-300x 防爆GW不锈钢称重模块,容量300t,,30M电缆GW-400x 防爆GW不锈钢称重模块,容量400t,,30M电缆GW-500x 防爆GW不锈钢称重模块,容量500t,,30M电缆GWA-15x 防爆GWA称重模块,容量15t,,13M电缆GWA-20x 防爆GWA称重模块,容量20t,,13M电缆GWA-30x 防爆GWA称重模块,容量30t,,13M电缆GWA-50x 防爆GWA称重模块,容量50t,,13M电缆GWA-100x 防爆GWA称重模块,容量100t,,13M电缆GWA-200x 防爆GWA称重模块,容量200t,,20M电缆GWA-250x 防爆GWA称重模块,容量250t,,20M电缆GWA-300x 防爆GWA称重模块,容量300t,,30M电缆GWA-400x 防爆GWA称重模块,容量400t,,30M电缆GWA-500x 防爆GWA称重模块,容量500t,,30M电缆产品型号产品描述UW-5x 防爆UW不锈钢称重模块,容量5kg,,3M电缆UW-10x 防爆UW不锈钢称重模块,容量10kg,,3M电缆UW-20x 防爆UW不锈钢称重模块,容量20kg,,3M电缆UW-50x 防爆UW不锈钢称重模块,容量50kg,,3M电缆UW-75x 防爆UW不锈钢称重模块,容量75kg,,3M电缆UW-100x 防爆UW不锈钢称重模块,容量100kg,,3M电缆UW-200x 防爆UW不锈钢称重模块,容量200kg,,3M电缆UW-300x 防爆UW不锈钢称重模块,容量300kg,,3M电缆UW-500x 防爆UW不锈钢称重模块,容量500kg,,3M电缆瑞士METTLER TOLEDO梅特勒托利多仪表类型料罐/料仓/定量打包秤专用仪表IND331/IND131系列称重仪表称重终端面板式IND331 33P100000000000 IND331 33P10000B000000 IND331 33P100000D00000 IND331 33P100000B00000 IND331 33P100000A00000 IND331 33P100000P00000 称重终端防尘式IND331 33H100000000J00 IND331 33H100000D00J00 IND331 33H100000B00J00 IND331 33H100000A00J00 IND331 33H100000P00J00称重终端导轨式IND131 13D100000000000 IND131 13D100000D00000 IND131 13D100000B00000 IND131 13D100000P00000 IND131 13D100000K00000IND131接线盒式IND131 13B100000000000 IND131 13B10000B000000 IND131 13B100000D00000 IND131 13B100000B00000 IND131 13B100000A00000 IND131 13B100000P00000 IND131 13D100000K00000IND245系列称重仪表称重终端普通型IND245 245G13000010J00 IND245 245G14000010J00 IND245 245G13001010J00 IND245 245G14001010J00 IND245 245G13002010J00 IND245 245G13003010J00 IND245 245G13004010J00 IND245 245G13010010J00 IND245 245G13011010J00 IND245 245G10001130J00 IND245 245G10002130J00 IND245 245G10011130J00 IND245 245G10012130J00称重终端防尘型IND245 245H13000010J00 IND245 245H14000010J00 IND245 245H13001010J00 IND245 245H14001010J00 IND245 245H13002010J00 IND245 245H13003010J00 IND245 245H13004010J00 IND245 245H13010010J00 IND245 245H13011010J00XK3123 IND320专用仪表产品型号产品描述IND320 32E100000000023,基本型,防护等级IP65IND320 32E10000B000023,配料型,防护等级IP65IND320 32E10000B001023,减量法,防护等级IP65IND320 32E10000A000023,模拟量型,防护等级IP65 IND320 32E10001B000023,配料型,防护等级IP65IND320 32E100000C00023,基本型,canopen接口,IP65 IND320 32E10000BC00023,配料型,canopen接口,IP65 应用领域IND320系列称重仪表广泛应用于:土建筑和建筑路面机械称重仪表技术参数瑞士METTLER TOLEDO梅特勒托利多接线盒类型接线盒AJB模拟类AJB-005 五孔模拟接线盒(不锈钢外壳)AJB-007 七孔模拟接线盒(不锈钢外壳)AJB-003 三孔模拟接线盒(不锈钢外壳)AJB-015接线盒DJB数字类DJB-004 四孔模拟接线盒(不锈钢外壳)DJB-005 五孔模拟接线盒(不锈钢外壳)DJB-006 六孔模拟接线盒(不锈钢外壳)DJB-007 七孔模拟接线盒(不锈钢外壳)接线盒AJB-X防爆类AJB-005X 防爆五孔模拟接线盒(不锈钢外壳)AJB-007X 防爆七孔模拟接线盒(不锈钢外壳)AJB-003X 防爆三孔模拟接线盒(不锈钢外壳)DJB-005X 防爆五孔模拟接线盒(不锈钢外壳)DJB-007X 防爆七孔模拟接线盒(不锈钢外壳)AJB-005N 五孔模拟接线盒(配新结构)AJB-007N 七孔模拟接线盒(配新结构)AJB-006N 六孔模拟接线盒(配新结构)AJB-003N 三孔模拟接线盒(配新结构)接线盒DJB-N数字类DJB-005N 五孔模拟接线盒(配新结构)DJB-007N 七孔模拟接线盒(配新结构)DJB-006N 六孔模拟接线盒(配新结构)DJB-004N 四孔模拟接线盒(配新结构)接线盒DJB-C数字类DJB-004C 四孔数字接线盒(GDD.用于标准汽车衡) DJB-005C 五孔数字接线盒(GDD.用于标准汽车衡) DJB-006C 六孔数字接线盒(GDD.用于标准汽车衡) DJB-007C 七孔数字接线盒(GDD.用于标准汽车衡)接线盒DJB-CN数字类DJB-004CN 四孔数字接线盒(GDD.用于新结构汽车衡) DJB-005CN 五孔数字接线盒(GDD.用于新结构汽车衡) DJB-006CN 六孔数字接线盒(GDD.用于新结构汽车衡)。
快讯28p. 10p. 8p. 6p. 4改进系统反馈监控系统最重要的功能之一是提供运行时数据以指示是设备性能。
该功能的有用性体现在两个方面:首先,它能够使您了解系统本身的运行情况;其次,它可以显示生产过程中其他元素的运行情况。
例如,通过质量控制设备剔除的产品数量增加可以发现上游设备可能性能不佳。
可使用性的重要性遗憾的是,许多生产问题都是由操作人员失误造成的。
设计欠佳或翻译不当的用户界面令操作人员感到头疼,导致产品转换过程出现延迟并且(当然)可能发生代价高昂的错误。
具有清晰可读且易于操作的界面的设备可减少这些问题,使事情顺利进行。
资源效率优化您公司的生产食物浪费既是一个经济问题,也是一个环境问题,是食品行业仍存在相当大改善空间的领域之一。
改进生产过程首先要提高生产效率。
降低产品召回风险的5 个简单步骤降低细菌污染风险高效肉类配份 — 一台秤 即可满足您的所有需求采用完整的产品检测解决方案, 提高生产效率卫生设计易于清洁可最大限度减少停机时间保持生产设备清洁不仅是一种好的做法,也是《食品安全现代化法案》等法律要求的重要组成部分。
虽然定期清洁设备是运营的一部分,但就像生产过程的其他部分一样,始终需要不断 改善。
设计时考虑清洁因素的设备符合这一要求。
这可以是能够实现水和其他洗涤剂径流的圆弧边缘、减少水平表面数量以防止集液,以及更容易清洁的易于拆卸的传送带。
`/cw-washdown高效人工称重确保清晰的用户指南高效和符合人体工程学的过程对于每天人工称重数以吨计的肉品非常重要。
台秤或平台秤的特定功能对于提高操作人员的效率非常重要。
在台秤应用中,I C S 秤的 c o l o r W e i g h ®和SpeedWeigh TM功能通常可将操作人员的效率提高25%。
称重金属容器时,PowerDeck TM平台秤会提醒操作人员将货物放在秤的最佳位置以提高可重复性。
过载或冲击载荷等主动警告功能可在错误变得严重之前将其消除。
梅特勒-托利多教育系列实验室电导率仪 (EL30)使用说明沪制01040055号目录页码 目录页码1.简介32.安全措施33.安装仪表 43.1 电极安装支架44. EL30 电导率仪操作 54.1 显示与按键54.2 校准74.2.1 校准设置74.2.2 校准74.3 样品测量74.4 参数设置74.4.1 设置温度补偿系数84.4.2 设置参比温度84.5 仪器自检84.6 恢复出厂设定84.7 出错信息95. 维护95.1 仪表维护96. 选配件107. 技术参数118. 附录128.1 电导标准溶液128.2 温度补偿系数实例128.3 误差限12梅特勒-托利多教育系列电导率仪1梅特勒-托利多教育系列电导率仪2梅特勒-托利多教育系列电导率仪3简介1. 简介非常感谢您购买梅特勒-托利多公司的高品质电导率仪,良好的易用性,是我们产品一贯的追求。
这款具有良好的用户界面,操作可靠的仪表,正是我们追求的体现。
教育系列实验室电导率仪(EL30)不仅仅具有高性价比,同时还具有以下优点:- 易于操作,操作手册会给您提供清楚易懂的操作指南。
- 卓越的人体工效学设计,使仪器与人体仿佛浑然一体。
- 多种配件可供您选择,如电极夹、电导标准液、和电化学测量指南等。
2. 安全措施操作人员防护措施- 切勿在有爆炸危险的环境中工作!因为仪表壳体并非气密型(可能因火花形成或者侵入气体引起的腐蚀而产生爆炸危险)。
- 使用化学品和溶剂时,请遵照供应商提供的操作指南和实验室安全规程进行操作!操作人员操作安全预防措施- 禁止将仪器的壳体分离。
- 仅允许梅特勒-托利多服务人员维修仪表!- 请避免下列环境因素的影响: 剧烈的震动长期处于日照下大气湿度超过 85%存在腐蚀性气体环境温度低于 5°C 或者超过 40°C强电场或磁场下安装仪表3. 安装仪表小心开箱取出仪表。
将校准证书存放在安全位置。
3.1电极支架安装1. 打开仪表上盖的支架杆插孔盖子,并存放在合适的地方。
METTLER TOLEDO(梅特勒-托利多)称重仪——培训资料注:本资料只针对梅特勒-托利多IND131/331型号称重仪,侧重于称重仪的标定及常见参数设置一、产品基本信息1 名称:METTLER TOLEDO(梅特勒-托利多)2 称重显示控制器型号: IND131/331防尘式3 称重传感器型号:SB-1t4 数量及分布:LT 入库区2台CT1 外部接口区2台CT1 尾料区1台CT1 清洁区2台CT1 装箱区3台CT2 外部接口区1台CT2 装箱区4台共15台二、传感器安装1 安装时每台称重仪均由4个传感器组成,其中一组对角为2个全浮动型传感器,另外一组对角为1个半浮动型传感器和1个固定型传感器2 安装时4个传感器要处于同一水平面3 按照传感器上的标牌指示进行接线+EXC 绿色电源正极-EXC 黑色电源负极SHELD 黄色(粗)屏蔽线+SEN 黄色(细)正反馈线-SEN 蓝色负反馈线+SIN 白色正信号线-SIN 红色负信号线三、称重显示控制器安装1 按照手册将各个模块插接并固定2 按照传感器的接线规则装接信号线(注意要接好屏蔽线)3 连接PROFIBUS DP线4 连接电源线(请确保主柜的相应的断路器断开)四、设置参数1 熟悉面板常用键功能2 数据含义3设置通信站址长按“打印”键3秒——通过“去皮”、“清皮”键选择“SET UP”菜单,按“打印”键进入——输入密码“1”,并进入——选择“通讯”菜单,并进入——选择“PLC”菜单,并进入——选择“PROFIBUS”,并进入——选择“节点地址”,并进入——设置通信站址——设置成功后按多次“清零”键,返回显示界面4设置密码长按“打印”键3秒——通过“去皮”、“清皮”键选择“SET UP”菜单,按“打印”键进入——输入密码“1”,并进入——选择“仪表”菜单,并进入——选择“用户”菜单,并进入——设置密码——设置成功后按多次“清零”键,返回显示界面五、称重仪的标定1 标定零点长按“打印”键3秒——通过“去皮”、“清皮”键选择“SET UP”菜单,按“打印”键进入——输入密码“1”,并进入——选择“称台”菜单,并进入——选择“标定”菜单,并进入——选择“标定零点”菜单,并进入——选择“空称”菜单,并进入——按“打印”键开始标定——显示标定成功,进行下一步2设置标定量程标定零点显示标定成功后,按“打印”键确认——按“打印”键选择“标定量程”——设置量程值——放置砝码3放置标准砝码:放置砝码时应该使4个传感器的受重均衡,并使重量在整个称重仪上均匀分布4标定量程放置砝码成功后,按“打印”键,开始标定量程——显示标定成功后,按按“打印”键确认——按多次“清零”键,返回显示界面注意:在标定零点和标定量程的过程中,不要碰触称台,以免造成干扰!5 测试效果进行效果测试时,应该先拿一个标准砝码,分别放置在四个传感器处,查看示数是否在误差范围内并且示数基本一致。