低损耗光纤连接器详解
- 格式:pdf
- 大小:172.11 KB
- 文档页数:4
Ultra Low Loss OM5, LC/UPC Uniboot to LC/UPC Uniboot, 2.0 mmDuplex Fiber Patch Cord, PlenumPatch cords using Uniboot technology combine, modularity, flexibility with easy insertion andremoval from connectivityUniboot connectors feature an adjustable polarity via a manual and independent rotation of eachsingle connector body without exposing the fibersUniboot technology features a push-pull mechanism operated by squeezing the connector bootProduct ClassificationRegional Availability Asia | Australia/New Zealand | Europe | Latin America | Middle East/Africa | North AmericaPortfolio CommScope®Product Type Fiber patch cord, duplexProduct Brand SYSTIMAX ULLOrdering Note For lengths greater than 999 ft (304 m), orders must be in meters | Minimum lengthmay vary based on cable configurationGeneral SpecificationsColor, connector A BeigeColor, connector B BeigeInterface, Connector A LC/UPCInterface Feature, connector A UnibootInterface, Connector B LC/UPCInterface Feature, connector B UnibootJacket Color Lime greenTotal Fibers, quantity2DimensionsCable Assembly Length Range (m) 1 – 999Cable Assembly Length Range (ft) 1 – 999Diameter Over Jacket 2 mm | 0.079 inOrdering Tree16Page ofMechanical SpecificationsCable Retention Strength, maximum11.24 lb @ 0 ° | 4.40 lb @ 90 °Optical SpecificationsFiber Mode MultimodeFiber Type OM5, LazrSPEED®Insertion Loss, maximum0.15 dBReturn Loss, minimum35 dBEnvironmental SpecificationsOperating Temperature-10 °C to +60 °C (+14 °F to +140 °F)Environmental Space PlenumRegulatory Compliance/CertificationsAgency ClassificationCHINA-ROHS Above maximum concentration valueISO 9001:2015Designed, manufactured and/or distributed under this quality management system ROHS Compliant/ExemptedUK-ROHSCompliant/ExemptedIncluded Products760251109P-002-MP-5G-F20LM/LTS–Fiber indoor cable, LazrSPEED® Plenum Light Duty Interconnect Cordage, 2 fiber, MultimodeOM5, Feet jacket marking, Lime green jacket color860658162– 2.0 mm LC Uniboot GEN 1.5, Lime GreenPage of26Page of 36Fiber indoor cable, LazrSPEED® Plenum Light Duty InterconnectCordage, 2 fiber, Multimode OM5, Feet jacket marking, Lime green jacket colorProduct ClassificationRegional AvailabilityAsia | Australia/New Zealand | Latin America | Middle East/Africa | North America PortfolioCommScope®Product TypeFiber indoor cable Product Series P-MPGeneral SpecificationsCable TypeMPO trunk cable Construction TypeNon-armored Subunit TypeGel-free Jacket ColorLime green Jacket MarkingFeet Total Fiber Count 2DimensionsDiameter Over Jacket 2 mm | 0.079 inRepresentative ImageMechanical SpecificationsMinimum Bend Radius, loaded38 mm | 1.496 inMinimum Bend Radius, unloaded16 mm | 0.63 inTensile Load, long term, maximum20 N | 4.496 lbfTensile Load, short term, maximum67 N | 15.062 lbfCompression 4 N/mm | 22.841 lb/inCompression Test Method FOTP-41 | IEC 60794-1 E3Flex300 cyclesFlex Test Method FOTP-104 | IEC 60794-1 E6Impact0.74 N-m | 6.55 in lbImpact Test Method FOTP-25 | IEC 60794-1 E4Strain See long and short term tensile loadsStrain Test Method FOTP-33 | IEC 60794-1 E1Twist10 cyclesTwist Test Method FOTP-85 | IEC 60794-1 E7Vertical Rise, maximum500 m | 1,640.42 ftOptical SpecificationsFiber Type OM5, LazrSPEED® wideband | OM5, LazrSPEED® widebandEnvironmental SpecificationsInstallation temperature0 °C to +70 °C (+32 °F to +158 °F)Operating Temperature0 °C to +70 °C (+32 °F to +158 °F)Storage Temperature-40 °C to +70 °C (-40 °F to +158 °F)Cable Qualification Standards ANSI/ICEA S-83-596 | Telcordia GR-409Environmental Space PlenumFlame Test Listing NEC OFNP (ETL) and c(ETL)Flame Test Method NFPA 130 | NFPA 262Environmental Test SpecificationsHeat Age0 °C to +85 °C (+32 °F to +185 °F)Heat Age Test Method IEC 60794-1 F9Low High Bend0 °C to +70 °C (+32 °F to +158 °F)46Page ofLow High Bend Test Method FOTP-37 | IEC 60794-1 E11Temperature Cycle0 °C to +70 °C (+32 °F to +158 °F)Temperature Cycle Test Method FOTP-3 | IEC 60794-1 F1Packaging and WeightsCable weight 3.2 kg/km | 2.15 lb/kft* FootnotesOperating Temperature Specification applicable to non-terminated bulk fiber cable56Page of860658162Page of 662.0 mm LC Uniboot GEN 1.5, Lime GreenProduct ClassificationRegional AvailabilityAsia | Australia/New Zealand | EMEA | Latin America | North America Product Type Fiber connector bootGeneral SpecificationsColor Lime greenDimensionsCompatible Cable Diameter 2 mm | 0.079 inPackaging and WeightsPackaging Type BagRegulatory Compliance/CertificationsAgencyClassification CHINA-ROHSBelow maximum concentration value REACH-SVHCCompliant as per SVHC revision on /ProductCompliance ROHSCompliant UK-ROHSCompliant。
超低损耗光纤技术及其应用介绍1 引言固网宽带和移动宽带的爆炸式增长,使得人们对带宽需求不断增加,100 Gb/s传输速率的波分系统预计在今后几年内将成为运营商骨干光网络的主导。
随着传输速率的提升,系统对光纤网络的光信噪比(OSNR),光纤色散,偏振模色散(PMD)和非线性的要求越来越高。
为此100 Gb / s系统引入了相干检测,高效频谱调制和数字信号处理(DSP)等技术。
在这些技术的支持下,100 Gb/s系统具有色散补偿(CD)和偏振模色散补偿的能力,从而降低了系统对光纤的要求。
目前研究人员把重点放在如何提高系统OSNR上,系统的OSNR决定了有光放大器的传输系统中信号的无电中继传输距离,理论上100 Gb/s 系统的OSNR要求比10 Gb/s系统高出10 dB。
解决这个问题可以采用新型的编码和频谱调制方式来提高OSNR,但即便如此,100 Gb/s的OSNR要求仍然高于以往系统。
另外也可以从光通信介质本身——光纤角度来考虑,提高传输距离和容量的探索回到了光纤发明之初的几十年里,人们所追求的不断降低光纤损耗的道路上。
2 光纤衰减的演进在光纤发明之前,人们主要研究利用大气传输光信号,尽管光波有着极大的带宽,但大气由于受到气候环境的严重影响,无法实现正常的通信。
用石英玻璃材料制成的光导纤维即光纤来传输光信号成为研究的重点。
但是当时普通石英玻璃材料的损耗高达1000 dB/km,传输距离很有限。
1966年高锟博士根据介质波导理论指出:光纤的高损耗并不是其本身固有的,而是由材料中所含的杂质引起的。
并预言如果降低材料中的杂质含量,可使得光纤的损耗降至20 dB/km甚至更小。
1970年,美国康宁(Corning)公司成功地研制了损耗为17 dB/km的低损耗石英光纤,把光纤通信由理论变成了现实。
1972年康宁又把光纤的损耗降到7 dB/km,1973年贝尔实验室发明的MCVD法制造光纤,光纤的损耗又降到2.5 dB/km。
光纤连接器原理及性能分析光纤对准是指将两根光纤的端面精确对准,以确保光信号的传输效率和质量。
光纤的端面需要经过打磨和抛光等工艺处理,以获得较高的平整度和光滑度。
将两根光纤的端面放置在连接器的插入孔中,并根据连接器的设计原理,通过插入孔和对准结构的引导将两个光纤的端面对准。
一般来说,光纤连接器的对准精度在微米级别。
光信号的传输是指光纤连接器通过光纤端面的精确对准,将光信号从一个光纤传输到另一个光纤。
当两个光纤的端面精确对准后,光信号可以在两个光纤之间以最小的损耗传输。
光信号由光源发出,经过光纤连接器的传输后,到达光接收器接收和解码。
在光纤连接器中,光信号的传输主要通过全反射的原理实现。
光纤连接器的插入孔和光纤接触面密封,避免光信号的漏泄和损耗。
插入损耗是指光信号从一个光纤传输到另一个光纤时的损耗。
插入损耗取决于连接器的设计和制造工艺。
一个优秀的连接器应该具有低插入损耗,通常在0.3dB以下。
回波损耗是指光信号由一个光纤传输到同一光纤时的损耗。
回波损耗也是连接器的一个重要性能指标,较低的回波损耗可以提高光纤通信系统的传输质量。
一般来说,回波损耗应该在50dB以上。
对准精度是指两个光纤端面之间的精确对准程度。
对准精度越高,光信号的传输质量越好。
对准精度受到连接器结构和工艺的影响,通常在1μm以下。
除了以上性能指标,光纤连接器的使用寿命、插拔次数、温度和湿度适应性还是一些重要的性能考量指标。
总之,光纤连接器是光纤通信系统中至关重要的组成部分,其原理和性能直接影响着光纤通信系统的质量和性能。
只有选择合适并具有良好性能的光纤连接器,才能确保光信号的有效传输和通信质量的提高。
12550 300MPO-LC / SC 1.610 48 3-9 242 1212MPO-MPO550 300128LazrSPEED® 550 MPO (female) to MPO (female), InstaPATCH® 360 Array Cord, 12-Fiber, LSZHAsia | Australia/New Zealand | EMEA | Latin America | North AmericaInstaPATCH® 360 | LazrSPEED®Minimum length may vary based on cable configuration | Not available in the United12MPO-12/UPC FemaleMPO-12/UPC Female12299916111.24 lb @ 0 ° | 4.40 lb @ 90 °-10 °C to +60 °C (+14 °F to +140 °F) Regulatory Compliance/CertificationsCHINA-ROHSDesigned, manufactured and/or distributed under this quality management system REACH-SVHC Compliant as per SVHC revision on /ProductCompliance860647054MPO12, LOW LOSS, FEMALE, OM3/4, AQUA, 3mmN-012-MP-5K-F30MPO12, LOW LOSS, FEMALE, OM3/4, AQUA, 3mmAsia | Australia/New Zealand | EMEA | Latin America | North America12-fiber60.1 mm | 2.366 in3 mm | 0.118 inOM3 | OM4ANSI/TIA-568-C.31Regulatory Compliance/CertificationsDesigned, manufactured and/or distributed under this quality management systemMaximum insertion loss change from -10 °C to +60 °C (+14 °F to +140 °F)Asia | Australia/New Zealand | EMEA | Latin America | NorthNon-armored12Gel-free123 mm | 0.118 in45 mm | 1.772 in24 mm | 0.945 in120 N | 26.977 lbf400 N | 89.924 lbf4 N/mm | 22.841 lb/in FOTP-41 | IEC 60794-1 E3FOTP-104 | IEC 60794-1 E6 0.74 N-m | 6.55 in lb FOTP-25 | IEC 60794-1 E4FOTP-33 | IEC 60794-1 E1FOTP-85 | IEC 60794-1 E7500 m | 1,640.42 ftOM4, LazrSPEED® 550 | OM4, LazrSPEED® 550-40 °C to +70 °C (-40 °F to +158 °F)ANSI/ICEA S-83-596 | Telcordia GR-409Low Smoke Zero Halogen (LSZH) | RiserNEC OFNR-LS (ETL) and c(ETL)IEC 60332-3 | IEC 60754-2 | IEC 61034-2 | IEEE 383 | UL1666 | UL 1685IEC 60794-1 F9FOTP-37 | IEC 60794-1 E11FOTP-3 | IEC 60794-1 F18.5 kg/km | 5.712 lb/kftRegulatory Compliance/CertificationsDesigned, manufactured and/or distributed under this quality management systemSpecification applicable to non-terminated bulk fiber cable550 360 12-Fiber, Asia | Australia/New Zealand | EMEA | Latin America | North AmericaInstaPATCH® 360 | LazrSPEED®12MPO-12/UPC FemaleMPO-12/UPC Female1222001711.24 lb @ 0 ° | 4.40 lb @ 90 °-10 °C to +60 °C (+14 °F to +140 °F) Regulatory Compliance/CertificationsCHINA-ROHSDesigned, manufactured and/or distributed under this quality management system REACH-SVHC Compliant as per SVHC revision on /ProductCompliance860647054MPO12, LOW LOSS, FEMALE, OM3/4, AQUA, 3mmP-012-MP-5K-F30MPO12, LOW LOSS, FEMALE, OM3/4, AQUA, 3mmAsia | Australia/New Zealand | EMEA | Latin America | North America12-fiber60.1 mm | 2.366 in3 mm | 0.118 inOM3 | OM4ANSI/TIA-568-C.31Regulatory Compliance/CertificationsDesigned, manufactured and/or distributed under this quality management systemMaximum insertion loss change from -10 °C to +60 °C (+14 °F to +140 °F)Asia | Australia/New Zealand | EMEA | Latin America | North AmericaNon-armored12Gel-free123 mm | 0.118 in45 mm | 1.772 in24 mm | 0.945 in120 N | 26.977 lbf400 N | 89.924 lbf4 N/mm | 22.841 lb/in FOTP-41 | IEC 60794-1 E3FOTP-104 | IEC 60794-1 E6 0.74 N-m | 6.55 in lb FOTP-25 | IEC 60794-1 E4FOTP-33 | IEC 60794-1 E1FOTP-85 | IEC 60794-1 E7500 m | 1,640.42 ftOM4, LazrSPEED® 550 | OM4, LazrSPEED® 550-40 °C to +70 °C (-40 °F to +158 °F)ANSI/ICEA S-83-596 | Telcordia GR-409IEC 60794-1 F9FOTP-37 | IEC 60794-1 E11FOTP-3 | IEC 60794-1 F19 kg/km | 6.048 lb/kftRegulatory Compliance/CertificationsDesigned, manufactured and/or distributed under this quality management systemSpecification applicable to non-terminated bulk fiber cable550 MPO/12(Female) MPO/12(Female), 24-Asia | Australia/New Zealand | EMEA | Latin America | North AmericaInstaPATCH® 360 | LazrSPEED®For additional jacket colors, please contact a CommScope Sales Representative | For lengths greater than 999 ft (304 m), orders must be in meters | Minimum length may12MPO-12/UPC FemaleMPO-12/UPC Female24420026111.24 lb @ 0 ° | 4.40 lb @ 90 °-10 °C to +60 °C (+14 °F to +140 °F)Regulatory Compliance/CertificationsDesigned, manufactured and/or distributed under this quality management system760161786N-024-MP-5K-F36AQ/D860647054MPO12, LOW LOSS, FEMALE, OM3/4, AQUA, 3mm。
光纤连接器特性介绍随着光通信系统飞速的发展,越来越多的网络业主发现质量低下的连接器造成的系统故障越来越多,而更令人吃惊的是,人们发现几乎所有的这些低质量的连接器都有不同程度的表面缺陷(如图)。
因此,现在大多数系统厂商要求连接器需要在400倍以上的显微镜下观察端面的劣质情况,如有无刮伤、污染程度、损伤面积等等。
虽然一些细微的缺陷在暂时使用时并不会对系统特性造成影响,但是,这种连接器经过长时间的使用或放置,一些表面缺陷在应力的作用下,会向周围扩展,在光纤纤芯表面产生更大的缺陷,如下几幅照片就是容易发生的。
轻微刮伤有缺口破损污渍侵蚀下面对光纤连接器的化学及物理特性作以简单的介绍:光纤连接的光学特性主要有插入损失(Insertion Loss)、反射损失(Return Loss),对于质量可靠度测试,目前国际上通用的是Bellcore-326标准,对于物理特性主要有偏心(Apex Offset),光纤内缩/突出量(Undercut/Protrusion),曲率半径(Radius of Curvature)和表面洁净度等特性,下面就上面提到的各种参数作简单介绍。
插入损失是用来衡量连接器给系统造成的光功率衰减(光连接器输出功率相对于输入功率dB值的相对减少量)用dB来表示。
现在的制造技术一般都能达到0.15dB以下。
测试波长通常用1310nm和1550nm两种,其中1550nm 波段具有较低的损耗特性,但他的弯曲损耗较大。
由于系统中要使用多个连接器进行接续,这样多个连接的插入损失之和会增加系统设计的功率代价。
因此要选用插入损失尽可能小的光连接器使用。
反射损失是用来衡量连接器端面的后向反射光大小的参数,根据非涅尔反射原理,光线遇到两种折射率不同的界面时会发生非涅尔反射。
在通信系统中反射的光信号进入光发射端机(激光器)会引起激光器的震动,产生功率及波长的漂移,给系统带来噪声,增大了系统的误码机会。
在CATV系统中光信号反射现象产生传输信号的时间滞后,使信号到达用户的时间延迟,从而造成图像的重影和清晰度下降。
光缆接头损耗标准
光缆接头损耗标准是指光纤连接器之间信号能量的损失量,通常以dB(分贝)为单位来表示。
在光纤通信中,熟练掌握光缆接头损耗标准是至关重要的,因为光缆接头损耗过大会影响光纤通信质量。
一般来说,光缆接头损耗标准的线性度应该小于0.3 dB。
如果接头损耗达到或超过0.3 dB,则需要进行必要的修正、测量和调整。
下面是一些常见的光缆接头损耗标准:
1. FC(Ferrule Connector,光纤连接器):FC光纤连接器是一种带有光纤咬合装置的单根光纤连接器,其损耗标准约为0.3 dB。
2. ST(Straight Tip,直尖):ST光纤连接器是在直径为2.5mm 的圆形插座上用旋转插头方式安装的,其损耗标准约为0.25 dB。
3. SC(Subscriber Connector,用户连接器):SC光纤连接器是一种插拔式的连接器,其损耗标准约为0.25 dB。
4. LC (Lucent Connector,朗讯连接器):LC光纤连接器是一种小型的插拔连接器,其损耗标准约为0.1 dB。
除此之外,在进行光缆接头损耗测试时,还需要注意以下几点:
1.测试环境应该保持干净,并且处于相对稳定的温度和湿度。
2.测试应该在合适的波长范围内进行,以确保准确性和一致性。
3.测试应该在特定的时间段内进行,以确保稳定和可重复性。
4.测试采用的测试仪器应该进行校准和维护。
总之,仔细掌握光缆接头损耗标准,选择合适的光纤连接器,以
及在测试时遵守标准规范,可以有效地提高光纤通信的质量和稳定性,为日后维护和升级工作打下坚实的基础。
光纤连接器的分类及特点介绍光纤连接器是一种用于连接光纤线缆的小型装置,它可以完成光纤端子连接和终止功能。
它是许多网络应用几乎必不可少的关键组件,特别是对光纤可靠性要求很高的水平,例如在无线通信、有线传输系统、光缆系统和光照等应用中。
常见的光纤连接器有SC,ST,FC,LC,MU,MTRJ等,主要表现形式有LC双扣型连接器,FC及SC 光纤连接器,ST光纤连接器,MU光纤连接器,MTRJ光纤连接器等。
这些连接器之间有一些不同之处,不同类型的连接器具有不同的性能特点。
SC连接器是最常用的光纤连接器之一,它采用了低损耗绝缘体剪切触点(POC)技术,具有工作可靠,插拔10000次以上、插拔无需特殊工具和安装便捷等优点。
此外,SC连接器的插座可以接受超过100W的功耗。
它可以应用于各种单模和多模光纤线缆上,通常用于Gigabit 以太网,CATV,语音/数据通信,视频系统,光纤传感器等场景。
ST连接器是应用最广泛的一种光纤连接器,它可以大大提高接合特性。
在接口部分,ST连接器采用了一种独特的"螺钉式连接"(也称为"Bayonet Lock Key"),具有高密度、高可靠性和可重复插拔的优点。
它由一支管状的外壳,内部装有三个紧固件:紧固螺钉,一个弹簧圈和一根保护管,可以使连接更加牢固。
这种连接器一般用于通信电缆,特别是室内或室外接口中的短距离光缆。
FC连接器的结构特征是把光缆销紧,使其不易脱落。
它采用高密度铰链式连接器技术,具有简单快捷的安装特性,不需要专业的技术人员才能完成安装,这也使得FC连接器非常受欢迎。
除此之外,FC连接器还具有灵活性、可靠性、低损耗等优点。
LC连接器采用相对小型化的半球锁定设计,具有低插入损耗和高可靠性等优点,具有较大的安装密度。
通常,在设计体积小的应用中,LC连接器是最常用的选择。
它的插头和座采用白金镀层,确保有极高的腐蚀保护能力,可以有效地防止进水,并延长其使用寿命。
减小光纤接头损耗的分析摘要:光纤线路是光通信系统中的重要设备,也是最基础的网络。
本文介绍了光纤线路在光通信系统中的作用,详细阐述了导致光纤线路接头处的传输信号损耗的原因。
结合工作实际经验,总结了光缆通信线路的传输衰耗存在是由于光纤的固有损耗和施工时接续损耗造成的具体原因。
分析施工操作对光缆通信线路产生的传输衰耗影响的关系,重点介绍了光纤在熔接过程中造成损耗的原因,为了提高光信号在光纤中传输的质量,提出了光纤在选材、规格型号、相关指标、施工规范、接续人员操作水平、光纤端面制作、熔接机的性能和正确使用等方面详细说明了在减小光纤传输衰耗方面可以采取的解决方法。
关键词:光纤;损耗;衰减;色散;熔接Abstract: Optical fiber line is an important device in optical communication system, and also the basic network. This paper introduces the role of optical fiber line in optical communication system, and detailedly expounds the causes of signal transmission loss in joint of optical fiber line. Combining with practical work experience, the author finds out thatthe signal transmission attenuation of optical cable communication lines isdue to the inherent loss of optical fiber line and construction joint loss., analyzes the relationship of the construction and the construction transmission attenuationto optical cable communication line, focuses on the introduction of the causes of the loss in the joint. In order to improve the transmission quality of optical signals in the optical fiber, the author puts forward the solutions in the material selection, specification models, related indicators, construction norms, personnel joint operation level, production of fiber end, welding machine performance and proper use ofoptical fiber line to reduct the signal transmission loss.Key words: optical fiber; loss; attenuation; dispersion; welding中图分类号:TN253文献标识码:A 文章编号:2095-2104(2012)引论目前,世界信息传输量的90%以上是通过光通信系统传输的。
低损耗光纤连接器详解
低损耗光纤连接器要求
●低损耗光纤连接器:10条连接器互相匹配最大插入损耗不大于0.2dB,典型插入损耗小于0.12dB光纤连接器活动在链路中的连接损耗主要有几个方面引起的:传光部分(纤芯core)横向失配、纵向失配、轴向失配等。
引起插入损耗(IL) 最主要的因素是横向失配。
当两个纤芯不同心的光纤连接器对对接时会引起损耗。
IEC标准对横向适配的要求
针对横向失配的解决方案
●解决办法
控制好连接器同心度,控制连接器同心度的方法。