E+H热量表说明书RMS621_TI00092Rzh
- 格式:pdf
- 大小:939.17 KB
- 文档页数:16
1.电磁流量计PROMAG50 2. 80F调试说明3.溶解氧COM223/COM253 4.CPM223/CPM253 ORP5.超声波测量仪FMU 23X6.压力变送器PMP717.在线测量浊度仪CUE218.在线COD测量仪9.雷达FMR24510.继电器(模数转换)RTA42111.72F调试说明12.重锤料位计FMM5013.DTT31质量流量计PROMAG50 电磁流量计一、参数设置10W调试说明1.仪表上电稳定后,按“E”键进入菜单组,出现“Group Select”Measuring Values2.按“+”或“-”,找到“Unit V olume Flow”,可用“+/-”键和“E”键确认体积流量单位,输入10,最后按“E”键确认;3.显示“Unit V olume Flow”,可用“+/-”键和“E”键确认质量流量单位;“m³/h”8.“Unit Totalizer”, 可用“+/-”键和“E”键确认累计值单位;“M³”10.“+”“-”同时按返回,再按“+”或“-”找到“Current Output ”按“E”,选择输出“4—20mA Hart Namur”,再按“E”,用“+、-”输入20mA对应的值,按“E”确认;11.按“E”到“Failsafe Mode”,按“+”或“-”,选择“Max current value”,及报警时输出最大电流值;12.同时按“+”“-”返回到“Current Output 1”,再按“+”或“-”找到“ProcessParameter”,按“E”,将“On-value low flow cut off”设置小流量切除值,一般的设置范围为20mA对应值的1%到5%;80F调试说明4.仪表上电稳定后,按“E”键进入菜单组,出现“Group Select”Measuring Values5.按“+”键两次出现“Quick Setup”,按“E”键进入,出现“Setup Commission”;No6.按“+”或“-”,输入80,最后按“E”键确认;7.重新出现Setup Commission”,按“+”键改为“Yes”,按“E”键确认;No8.显示“Language”选择语言为英语,按“E”键确认,如需选其它语言先用“+”“-”键选择再用“E”键确认;9.显示“Pre-setting”,按“E”键确认;“Act-setting”10.显示“Unit Mass Flow”,可用“+/-”键和“E”键确认质量流量单位;“Kg/h”8.“Unit Totalizer”, 可用“+/-”键和“E”键确认累计值单位;“Kg”9.“Configuration other Unit?”,可用“+/-”键和E键,选择“No”;10.“+”“-”同时按返回到“Quick Setup”菜单,再按“+”或“-”找到“Current Output 1”按“E”,选择输出“4—20mA Hart Namur”,再按“E”,用“+、-”输入20mA对应的值,按“E”确认;11.按“E”到“Failsafe Mode”,按“+”或“-”,选择“Max current value”,及报警时输出最大电流值;12.按“E”返回到“Current Output 1”,再按“+”或“-”找到“ProcessParameter”,按“E”,将“Assign cutoff”选为“Mass flow”,按“E”键,在“On-value low flow cut off”设置小流量切除值,一般的设置范围为20mA对应值的1%到5%;Liquisys COM223/COM253溶解氧调试方法一、调试:(1) 操作说明 :下面对各个操作键进行说明:CAL键:标定,激活标定模式,标定菜单显示。
eh流量计说明书篇一:EH6400A电子表头操作说明EH6400A电子表头操作说明仪表通电后首先显示产品型号及版本号,再显示仪表功能F12 34 及生产日期,进入运行状态。
现场显示=F10XXXX 二线制4-20mA=F11XXXX 三线制4-20mA=FXX01XX 脉冲输出=FXXXX01 RS485通讯非标1、键盘说明EH6400A共有三个按键【S】【+】【-】,二种按键方式(短按和长按(按住不松直到显示变化)),【S】:运行状态下,(短按)单次量和累计量切换。
(长按)清零单次量。
设置状态下,(短按)移动闪烁位(即修改位)【+】:运行状态下,(长按)清零累计量设置状态下,(短按)闪烁位加1(即修改位)【-】:设置状态下,(短按)闪烁位加1(即修改位)(长按)表示【确认】2、参数设置EH6400A在运行状态下,(长按)【-】进入密码输入状态。
输入正确的密码后,(长按)【-】仪表进入设置状态。
仪表设置状态共有四组操作菜单《L参数设置》《F参数设置》《C参数设置》《修改密码》四组操作通过(长按)【-】进行循环切换。
需要修改某个参数时可通过【S】【+】【-】(短按)来实现。
3、退出设置EH6400A在设置状态下,按【+】+【-】(表示同时按,后类同)仪表显示SAUEd,此时(长按)【-】仪表保存参数成功显示SUCCESS闪动即返回运行状态,保存失败则显示Err闪动即返回运行状态。
(短按)【S】则不保存返回运行状态。
4、参数说明第一组参数:L00-----系数0(主系数)(单位0.00000L/脉冲)L01-----系数1L02-----系数2L03-----系数3L04-----系数4L05-----第一个分段值(单位000.000m3/h)L06-----第二个分段值L07-----第三个分段值L08-----第四个分段值L09-----分段开关(0:不分段,1:分段)注不分段时采用系数0(主系数)。
WMLR热量表说明书湖南威铭能源科技地址:长沙市高新产业开发区咸嘉湖路352号::http:// E-mail目录WMLR热量表说明书....................... 错误!未定义书签。
第一章企业介绍............................... 错误!未定义书签。
第二章超声波热量表原理 ............... 错误!未定义书签。
热量表概念.................................................................................................................. 错误!未定义书签。
组成.............................................................................................................................. 错误!未定义书签。
工作原理...................................................................................................................... 错误!未定义书签。
测量原理...................................................................................................................... 错误!未定义书签。
超声波热量表的优势 .................................................................................................. 错误!未定义书签。
标准型热计量表使用说明一、主要功能该型号热量表为整体式热量表,由基表、表壳、流量传感器(韦根模块)、温度传感器(Pt1000配对热电阻)、操作按键及LCD等部分组成。
系统的主要功能如下:1、流量采集1)自动采集流量信号并计算流量(流速)和累积流量(体积)。
2) 根据基表处水温的不同,采用不同的仪表流量系数,分25(常温),55,90℃三种情况。
2、温度采集1)自动采集进水温度、出水温度并进行温差计算。
温度采集出错时,记录出错时间。
2 ) 温度采集范围:0-100℃。
3)为节约电池,当LCD有显示或有流量时才采集温度。
3、热量计算1) 温度采集正常时,计算供热系统散发的能量并累计进行热量计算。
2) 进水温度范围6—95℃,出水温度不低于5℃,进出水温差不低于 3℃4、电压监测自动进行电源电压监测。
但显示的电压不是电压的实际值,正常情况下显示3.6V,低压时显示0.0V。
5、时间功能1)根据内部时钟自动计算年月日(万年历),累计上电后的工作时间和故障时间(小时数)。
2) 程序写入芯片后,系统上电才开始进行时钟累计,因此显示的日期与实际的日期可能不对应,可以利用按键进行调整。
另外,日期的变化时间与系统的上电时间也有关系,并不是在23点59分59秒的时候变化。
例如系统在10点30分25秒上电,上电后内部计数器从0开始计数,则到第二天的10点30分25秒时,内部计数器累计时间选到24小时,日期发生变化。
利用提供的时钟校正功能,可以进行时钟校正并使计数器从0点开始计数。
6、仪表流量系数、温度参数修正和时钟校正不同的热量表基表其流量系数可能会有微小的差别,批量生产时,程序写入的是统一的系数,必要时可以进行修正。
不同的热量表,电子元器件会有微小的差别,测温的PTl000也会有差别。
批量生产时,程序写入的是统一的温度参数,必要时可以进行修正。
采用提供的通讯程序和通讯设备,可以利用计算机与热表进行通讯,修改仪表流量系数、温度参数和系统的时钟。
BA057D/06/zh/06.0550098468PROline promass80科氏力质量流量测量系统操作指南简明操作指南该操作指南指导您对测量仪表进行快速简便的设定安全指南第页7安装第页31接线第页13第页23显示和操作单元使用“快速设定”进行调试QUICK SETUP ()第页50您可使用“快速设定”菜单对测量仪表进行快速、方便的调试,使用现场显示设置基本功能,如显示语种、测量变量、变量单位、信号种类等以下功能可单独实现(如需要):-零点校正-密度校正-电流输出设置(有源无源)QUICK SETUP()/用户专用设置复杂测量操作需要某些附加功能,您可以借助于功能矩阵进行设置,并将其用户化以满足您的测量过程需要提示:所有功能的详细描述,请查阅“”手册功能描述提示:如在调试后或操作过程中出现故障,请启动故障诊断,见第页诊断清单,找出故障原因以及相应的排障措施。
61第页52主显示页快速设定初始化质量流量E E语言预设定体积流量标准体积流量密度温度退出质量流量单位体积流量单位密度单位温度单位累积器单位累积器单位参考密度单位参考密度值设定其他单位?选择系统单位是否测量模式选择输出模式电流输出1电流输出2频率/脉冲输出退出操作模式频率脉冲电流对应变量电流对应变量电流范围电流范围0/4mA 对应值20mA 对应值时间常数失效模式0/4mA 对应值20mA 对应值时间常数频率对应变量频率上限频率下限频率上限值输出信号时间常数脉冲对应变量脉冲当量脉冲宽度输出信号失效模式失效模式设定其他输出?是否自动设定显示是否自动设定显示参数失效模式标准体积流量单位快速设定提示:快速设定菜单的详细信息,尤其是不带现场显示仪表的操作,请查阅第页。
50·在参数输入过程中按ES C 键,返回QU I CK S ET U P CO MM I SS I O N ,所设定的参数值有效·在进行以下快速设定前必须启动“快速设定”功能·①对当前设定中未设置的单位进行选择,在相应的流量单位中选择质量流量、体积流量、标准体积流量单位·②保持“Y E S ”选项,直到所有单位设置完成“N O ”选项表示没有需要设置的单位·③只对当前设定中未设置的输出进行选择·④保持“Y E S ”选项,直到所有输出设置完成“N O ”选项表示没有需要设置的输出·⑤“参数化显示”包含下列基本设定/出厂设定:YE S :第一行=质量流量;第二行=累积量1;NO :保持现有的设定提示:正确使用安装、调试和操作操作安全返修安全规范和图标名称变送器铭牌传感器铭牌标志,一致性声明注册商标收货确认、运输和储存收货确认运输储存安装条件尺寸安装位置安装方向伴热保温进出口直管段振动限流安装指南旋转变送器外壳墙挂式变送器安装旋转现场显示模块安装后的检查分离型仪表的连接传感器的连接电缆规格测量单元的连接变送器的连接端子分配连接防护等级接线后的检查显示和操作单元功能矩阵简明操作指南注意事项激活编程模式禁止编程模式错误信息通信操作选项仪表和过程变量1.安全指南.标识...7....................................................2 (9)1.1...............................................................71.2..........................................71.3...............................................................71.4.....................................................................81.5. (8)2.1 (9)2.1.1...................................................92.1.2.................................................102.2CE ....................................102.3.............................................................113.1.. (13)3.1.1....................................................133.1.2............................................................133.1.3............................................................143.2. (14)3.2.1.............................................................143.2.2....................................................143.2.3....................................................163.2.4............................................................183.2.5............................................................193.2.6.............................................193.2.7............................................................193.2.8............................................................193.3 (20)3.3.1.........................................203.3.2......................................213.3.3.......................................223.4......................................................224.1. (23)4.1.1..............................................234.1.2....................................................244.2. (25)4.2.1.............................................254.2.2....................................................274.2.3HART .................................................284.3......................................................294.4....................................................305.1.............................................315.2.. (32)5.2.1......................................................335.2.2............................................335.2.3............................................335.3.......................................................345.4. (35)5.4.1....................................................355.4.2 (36)仪表3.................................................................134...................................................................235...................................................................31安装接线操作目录5.4.3/HART .................375.4.4/..................................436.1...................................................496.2. (49)6.2.1..........................................496.2.2....................................506.2.3.................................................526.2.4.................................................546.2.51/.............................556.2.62/............................566.2.7..............................579.1............................................619.2............................................629.3............................................679.4.............................699.5..............................................709.6........................................................729.7.............................739.8....................................779.9...................................................78.........................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................通用型普通应用型指令仪表状态错误信息功能检测调试测量仪表上电快速设定“调试”零点校正密度校正电流输出:有源无源电流输出:有源无源吹扫和压力监测连接故障诊断指南系统错误信息过程错误信息无显示信息的过程错误输出响应错误备品备件更换和安装印刷线路板仪表保险丝的更换软件版本6.................................................................497................................................................588................................................................599.......................................................6110.....................................................调试维护附件故障诊断技术参数一览应用功能和系统设计输入输出供电性能特性操作条件机械结构用户接口认证订货信息附件相关文件尺寸;墙挂式变送器尺寸:不锈钢现场变送器技术参数8110.18110.1.18110.1.28110.1.38110.1.48310.1.58310.1.68410.1.78810.1.89710.1.910010.1.1010010.1.1110010.1.1210110.1.1310110.210210.310210.4(P r om a s s F ,M ,A,H ,I )....10310.5尺寸:分离型(P r om a s s E )10310.6尺寸:分离伴热型10310.7尺寸:高温型(一体化型)10410.8尺寸:高温型(分离型)10410.9尺寸:Pr o ma ss F 10510.10尺寸:Pr o ma ss M 11510.11尺寸:Pr o ma ss E 12910.12尺寸:Pr o ma ss A 13810.13尺寸:Pr o ma ss H 14410.14尺寸:Pr o ma ss I 146尺寸:分离型.....................................................................................................................................................................................................................................................................................................................................................................................1安全指南1.1正确使用PR Ol in e P ro ma s s 8系列流量计用于测量液体和气体的质量流量,同时也可测量流体密度和温度。
亿林热量表技术路线框图热量表是多功能、智能化热计量装置,属于机电一体化技术亿林一、工作原理通过测量流过热交换系统的介质流量和进出口温度而得到耗热量,计算公式如下:式中:Q—释放或吸收的热量(J 或Wh。
q m —流经热量表的水的质量流量(kg/h。
Δh—在热交换系统的入口和出口温度下,水的焓值差(J/kg。
τ——时间(h。
二、结构领域。
该产品由流量计、流量信号采集器、计算器、显示器、温度传感器五大部件构成。
技术路线框图如下:∫Δ=1τττhd qQ m亿林热量表使用说明书亿林热量表主要型号热量表主要规格三、应用范围适用于以水为媒体的热交换系统的热(冷量计量。
主要用于计量居民住宅和公共建筑采暖耗热量,也可用于中央空调系统计量供冷量,还可用于化工、发电、制药等工业领域。
该产品适应了国家推行供热体制改革,实行采暖分户热计量的需要。
四、产品执行标准与准确度等级产品执行标准:中华人民共和国城镇建设行业标准《热量表》(CJ 128-2000。
产品检定规程:中华人民共和国国家计量检定规程《热能表》(JJG 225-2001计量准确度:产品计量准确度为《热量表》(CJ 128-2000规定的3级标准。
五、规格型号规格:公称直径DN(毫米15 20 2532 40 50 65 80 100150 200 250300普通型热/冷兼用型数据通讯型JHM -P JHM -RL JHM -I JHM -R JHM -M 无数据通讯接口既可计热,又可计冷脉冲式接口RS485接口 M -BUS 接口亿林六、主要技术特性1.主要技术参数300 公称口径/Norminal Calibermm15 20 25 32 40 50 65 80 100125150200250 1200 最大流量/Max.Flow-rate Qmaxm3/h 3 5 7 12 20 30 50 80 120200300500800600 常用流量/the Permanent Flow-rate Qpm3/h 1.5 2.5 3.5 6 10 15 25 40 60 10015025040048 最小流量/Min.Flow-rate Qminm3/h 0.030.050.070.120.20.45 0.75 1.2 1.8 4 4.57.532 最大工作压力/MAPMPa 1.6最大压力损失/Max.Preasure lossMPa ≤0.025温度上限/the highest temperature Tmax℃ 95温度下限/the lowest temperature Tmin℃ 4最大温差/Max.temperature difference ΔTmax ℃ 75最小温差/Min.temperature difference ΔTmin ℃ 3温度传感器电缆长度m ≥1.5Cable Length Of Temperature Sensor使用环境/Working EnvironmentB类温度: -5℃~55℃相对湿度:≤80%保护等级/Protection ClassIP54电池工作年限/Battery Service Year年 >6- 3 -2、压力损失特性0.000.010.020.030.040.050.060.070.080.09 0.10压力损失△P(M P a 瞬时流量Q (m 3/h0.0000.0050.0100.0150.0200.0250.030压力损失△P (M P a 瞬时流量Q (×100 m 3 /h压力损失特性曲线七、显示功能按压薄膜开关,显示内容按下列图示依序前进:全屏显示累积热量累积流量瞬时流量进水温度回水温度进回水温差累积工作时间累积脉冲数进水温度传感器正常(左)、故障状态(右)回水温度传感器正常(左)、故障状态(右)流量传感器正常(左)、故障状态(右)电池电压状态(左正常,右欠压)当前日期当前时间热量校验流量校验 -6-2、安装使用说明(1)热量表运抵施工现场后,在安装前应存放于包装箱内,避 -7-免雨林、重压和摔橦。
E+H 流量计说明书一 .用途及使用方法 1. 检测显示酒水的瞬时流量和累积流量并以频率信号传送给PLC. 2. 接线如图24 25 L NPLC ~220V 二 .参数设臵按E 进入主菜单,按ESC )可以退出进入测量SYSTEM UNITS (系统单位) UNIT VOL FLOW (流量单位) m 3/hUNIT VOLUME (量度) m3OPERATION (操作) LANGUAGE (语言) ENGLISH (英语)ACESS CODE (进入密码) 0050USER INTERFACE (用户面板) ASSIGN LINE1( 首 行 显 示 )VOLUME FLOW (流量)ASSIGNLINE2(末行显示)TOTALIZER (总量)PUL/FREQ OUT OPERATION MODE(操作模式) FREQUENCY (频率)END VALUE FREQUENCY (满流量频率) 1000HZ 分别对应 VALUE F MAX (满流量) 12(T )水60(T)酒二、安装1.安装位臵只有当满管时才能获得准确的测量,要避免以下安装位臵:(1)管道最高点(易聚积气泡);(2)直接向下的管线的敞开出口前;(3)泵的入口侧(防止抽压而造成的对流量管衬里的破坏);(4)有残渣聚积的场合和排水管的最低点(最好安装一个清洁阀)。
2.安装方位最适宜的方位可帮助避免气体的累积和测量管内的残渣存积。
垂直安装、流体自下而上的安装位臵为最佳方位。
若为水平安装,测量电极平面必须水平,这样可以防止由于夹带的气泡而产生的电极短时间绝缘。
空管检测功能仅当测量装臵为水平安装及变送器外壳向上时能正确工作。
3.振动如果振动剧烈,注意支撑管道和传感器;若振动非常剧烈应将传感器和变送器分开安装。
不允许利用外框承住传感器的重量,这会使外框变形并破坏内部励磁线圈。
4.出入口直管段安装传感器时要尽量避免阀门、三通、弯头等组件,与他们之间的距离应能保证所需的进口和出口直管段以确保测量精度:入口长度≥5DN,出口长度≥2DN。