LC系列说明书(中文)-V3.0
- 格式:pdf
- 大小:2.26 MB
- 文档页数:29


WeighfeederOperation Manual定量给料机LCXK-Ⅲ操作手册承德承信自动化工程有限公司目录一概述讲述皮带秤操作原理及具体情况,如“出料点供料。
什么是INTECONT PLUS ..................2 定义....................................2 计量原理...............................2 控制....................................2 输入和输出.............................3二技术数据和字符....................3 本章简要介绍INTECONT所用全部数据和所有可能发生的情况。
技术数据................................4 接口....................................5 对话语言、单位..........................5 显示、指示灯期..........................5 程序设置、标定..........................6三程序设置..........................7 程序设置功能便于以少量的运算完成秤体计量要求。
功能分配...............................7 标定功能...............................8 皮带环形LB ...........................8除皮TW...............................9置零..................................9 砝码检查CW...........................9模拟方式...............................10 时间设置...............................11四服务值............................11 服务值信号适用于外部线缆、输入、输出转换和负荷传感器负载等检查。
LC-3060微型高压输液泵一、核心技术1. 该产品采用高于ARM7的COTREM-M3系列微处理器2. 该产品采用电子压力脉动抑制技术3. 该产品采用高精度直流伺服电机4. 该产品采用浮动柱塞设计5. 该产品可根据说明书用户自行更换(10mL/50mL)泵头二、技术指标10mL流速范围0.01~9.99 mL/min输液结构双柱塞串联式;电子压力脉动抑制流量精度±0.14%(1mL/min,二次水,室温)流速重现性0.03%(1mL/min,二次水,室温)压力范围0~45 MPa(1mL/min,二次水,室温)压力脉动<0.1MPa(1mL/min,甲醇水,接柱,15MPa)控制RS-232/485接口,可计算机反控显示LCD 2×8英文显示电源24V,3A直流尺寸/重量130×110×210 mm(长×高×深)/2.8Kg10mL--PEEK流速范围0.01~9.99 mL/min输液结构双柱塞串联式;电子压力脉动抑制流量精度±0.14%(1mL/min,二次水,室温)流速重现性0.03%(1mL/min,二次水,室温)压力范围0~35 MPa(1mL/min,二次水,室温)压力脉动<0.1MPa(1mL/min,甲醇水,接柱,15MPa)控制RS-232/485接口,可计算机反控显示LCD 2×8英文显示电源24V,3A直流尺寸/重量130×110×210 mm(长×高×深)/2.8Kg50mL流速范围0.01~49.99 mL/min输液结构双柱塞串联式;电子压力脉动抑制流量精度±0.2%(1mL/min,二次水,室温)流速重现性0.5%(1mL/min,二次水,室温)压力范围0~32 MPa(1mL/min,二次水,室温)压力脉动<0.1MPa(1mL/min,甲醇水,接柱,15MPa)控制RS-232/485接口,可计算机反控显示LCD 2×8英文显示电源24V,3A直流尺寸/重量130×110×210 mm(长×高×深)/2.8Kg三、产品应用范围1.可作为高效液相色谱分析的输液泵使用,液路连接方面兼容全球所有HPLC系统制造厂商的HPLC产品2.可作为液相色谱半制备系统的输液泵使用3.可作为制备系统的进样泵使用4.惰性泵可作为离子色谱输液泵使用5.其他需要高压、稳定的输液需求6.可配套相应的检测器、进样阀、色谱柱组成HPLC(包括IC离子色谱)系统7.接续管线规格为:1/16’OD,不锈钢、PEEK或PTFE材质四、产品特点●静音,无机械噪音●超小型化设计,节约空间,方便携带●无机械缓冲器(电子压力脉动抑制)●可根据需求更换泵头(分析/半制备)●可选配惰性系统●可通过RS-232/485接口进行外部控制,通讯方式RS-232/485可通过端口进行智能识别●车载电源可使其适于野外作业应用五、泵头及配件80%的重要零部件全部为进口产品,稳定性让您无忧:●美国Bal Seal密封圈●进口瑞士Ceramaret精密柱塞●进口美国H&H不锈钢输液管●瑞士CERAMARET公司的单向阀六、泵与液路接触的全部材料:用于常规实验分析,耐高压、耐腐蚀。
Submittal Data —PERFORMANCE DATA —CERTIFIED DIMENSION PRINTS —CERTIFIED ROOF CURBDIMENSION PRINTSE Carrier Corporation2016Edition Date:08/16Printed in U.S.A. Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations.Catalog No:50LC---14---26---05SB Replaces:50LC---14---26---04SBJob Data:Location:Buyer:Buyer P.O.#:Carrier: Unit Number:Model Number:Unit Designation:Performance Data Certified By:DESCRIPTION50LC units are ultra high--efficiency,single--packaged electric cooling,with optional electric heating units.Units utilize three stages of cooling capacity control with matching indoor fan motor speed control.All models are available with belt drive indoor fan motors with V ariable Frequency Drive(VFD)speed controller and Direct Drive-ECM outdoor fan motors.Models use electro mechanical controls with Carrier’s Comfort Control Logic and LED indicators. All units are factory tested in both heating and cooling modes,and rated in accordance with AHRI Standards 340/360.STANDARD FEATURES Base UnitS Puron R(R--410A)HFC refrigerantS IEERs up to19.3with with EERs up to12.6S ASHRAE90.1--2013compliantS Rated in accordance with AHRI Standards340/360S Designed in accordance with Underwriters Laboratories Std1995S Listed by ETLS3--stage cooling capacity control with crankcase heatersS Belt drive indoor fan and pulley system with V ariable Frequency Drive(VFD)controllerS High--efficiency ECM outdoor fan motorS Exclusive non--corrosive composite condensate pan in accordance with ASHRAE62Standard,sloping design; side or center drainS Standard ambient cooling operation down to40_F(4_C) with lower operation with integrated economizer. SystemVu t controls allow operation down to0_F (--18_C).All units operate up to125_F(52_C).S Dedicated vertical and horizontal airflow models available ordered as factory option.No special kits required.S Proven multi staged scroll compressors with internal line--break overload protectionS Single refrigerant circuit design with full face activated evaporator coilS Two--inch disposable return air filters on slide out track. Four--inch track available as field--installed accessory. S Provisions for thru--the--bottom power entry capability as standardS Single point electric connections S24--volt control circuit protected with resettable circuit breakerS Permanently lubricated evaporator--fan motorS Totally enclosed condenser motors with permanently lubricated bearingsS Low--pressure and high--pressure switch protectionS Full perimeter base rail with built--in rigging adapters and fork truck slotsS Sound levels as low as84dBS New terminal board facilitating simple safety circuit troubleshooting and simplified control box arrangement CabinetS Innovative,easy starting,no--strip screw feature on unit access panelsS Access panels with easy grip handles and tool--less filter access doorS Pre--painted exterior panels and primer--coated interior panels tested to500hours salt spray protectionS Fully insulated cabinet with foil faced insulation Refrigerant SystemS Precision sized TXV refrigerant metering devicesS High capacity liquid line filter drierS High performance internally enhanced copper tube, aluminum fin coils with optional corrosion resistant coils Standard Limited Parts WarrantyS5--year compressor partsS5--year electric heaterS3--year SystemVu t controllerS1--yearpartsPERFORMANCE DATAUnit Operating Weight lb Curb Weightlb CoolingGross Total Capacity:Btuh at Condenser Air Temperature _F Gross Sensible Capacity:Btuh Compressor Power Input:kW Indoor Entering db _F wb _F Airflow CFM External Static Pressure in.wg Indoor Fan Motor Size Hp Exhaust Fan Motor SizeHpHeating (Electric)Total Heating Capacity:INPUT Stage 1Btuh Stage 2BtuhOUTPUT Stage 1kW Stage 2kW Thermal Efficiency State%ELECTRICAL DATAPower Supply to Unit V oltsPhaseHzMinimum Circuit AmpsMaximum Overcurrent ProtectionSUBMITTAL DATAJob Name Architect Engineer Contractor UnitDesignationUse of the AHRI Certified TM Mark indicates a manufacturer’s participation in theprogram For verification of certification for individual products, go to.FACTORY--INSTALLED OPTIONS(FIOPs)j Economizer with D RY B ULB sensing and barometric relief.Standard Air Leak Dampers—f Models with W7220controller meet CaliforniaTitle24(section120.2)Fault Detection andDiagnostic(FDD)requirements.EconoMi$er X.f Models with RTU Open controller meet CaliforniaTitle24(section120.2)Fault Detection andDiagnostic(FDD)requirements.EconoMi$er2.j Economizer with E NTHALPY sensing and barometric relief.Standard Air Leak Dampers—f Models with W7220controller meet CaliforniaTitle24(section120.2)Fault Detection andDiagnostic(FDD)requirements.EconoMi$er X.f Models with RTU Open controller meet CaliforniaTitle24(section120.2)Fault Detection andDiagnostic(FDD)requirements.EconoMi$er2.j Economizer with D RY B ULB sensing and barometric relief.ULTRA LOW LEAK Air Dampers—f Models with W7220controller meet CaliforniaTitle24(section120.2)Fault Detection andDiagnostic(FDD)requirements,have return,outsideair and relief damper leakage that meet Title24(section140.4and ASHRAE90.1--2013)requirements-plus5--year limited parts warranty.EconoMi$er X.f Models with RTU Open controller meet CaliforniaTitle24(section120.2)Fault Detection andDiagnostic(FDD)requirements,have return,outsideair and relief damper leakage that meet Title24(section140.4and ASHRAE90.1--2013)requirements-plus5--year limited parts warranty.EconoMi$er2.j Economizer with E NTHALPY sensing and barometric relief.ULTRA LOW LEAK Air Dampers—f Models with W7220controller meet CaliforniaTitle24(section120.2)Fault Detection andDiagnostic(FDD)requirements,have return,outsideair and relief damper leakage that meet Title24(section140.4and ASHRAE90.1--2013)requirements-plus5--year limited parts warranty.EconoMi$er X.f Models with RTU Open controller meet CaliforniaTitle24(section120.2)Fault Detection andDiagnostic(FDD)requirements,have return,outsideair and relief damper leakage that meet Title24(section140.4and ASHRAE90.1--2013)requirements-plus5--year limited parts warranty.EconoMi$er2.j Electric Heatersj Non--fused disconnectj HACR breakerj Powered115--volt convenience outletj Non--powered115--volt convenience outletj Return air smoke detectorj Supply air smoke detectorj CO2sensorj Condenser hail guard-louvered stylej Special coating protection for evaporatorand condenser coilsj Hinged access panelsj Patented Humidi--MiZer R adaptive dehumidification system(not available with SystemVu t controls)j RTU Open multi--protocol controller communicates to LON,MODBUS*,BACnet{and Johnson N2protocols.j SystemVu t Controls:BACnet is a registered trademark of ASHRAE.ASHRAE does not endorse, approve ortest products for compliance with ASHRAEstandards. Compliance of listed products tothe requirements of ASHRAE Standard 135is the responsibility of BACnet International (BI).BTL is a registered trademark of BI.S Large full text-multi line displayS Intuitive multi button navigationS USB Flash Port for data transferS Built in i--Vu R,CCN and BACnetS Refrigerant pressure from displayS Quick LED Status-Run,Alert,FaultS Historical component runtime and startsS Conventional Stat or Sensor capabilitiesS Cooling Operation down to0_F(--18_C) OPTIONAL EXTENDED WARRANTIESj Complete Unit Parts only up to5yearsj Complete Unit Parts and Labor up to5years Many other optional warranties are available.See the Commercial Start--Up and Optional Extended Warranty Price price pages for further information.*MODBUS is a registered trademark of Schneider Electric.{BACnet is a registered trademark of ASHRAE(American Society ofHeating,Refrigerating and Air---ConditioningEngineers).FIELD--INSTALLED ACCESSORIESj Economizer with D RY B ULB sensing and barometric relief.Standard Air Leak Dampers—f Models with W7220controller meet CaliforniaTitle24(section120.2)Fault Detection andDiagnostic(FDD)requirements.EconoMi$er X.f Models with RTU Open controller meet CaliforniaTitle24(section120.2)Fault Detection andDiagnostic(FDD)requirements.EconoMi$er2.j Economizer with E NTHALPY sensing and barometric relief.Standard Air Leak Dampers—f Models with W7220controller meet CaliforniaTitle24(section120.2)Fault Detection andDiagnostic(FDD)requirements.EconoMi$er X.f Models with RTU Open controller meet CaliforniaTitle24(section120.2)Fault Detection andDiagnostic(FDD)requirements.EconoMi$er2.j Economizer with D RY B ULB sensing and barometric relief.ULTRA LOW LEAK Air Dampers—f Models with W7220controller meet CaliforniaTitle24(section120.2)Fault Detection andDiagnostic(FDD)requirements,have return,outsideair and relief damper leakage that meet Title24(section140.4and ASHRAE90.1--2013)requirements.EconoMi$er X.f Models with RTU Open controller meet CaliforniaTitle24(section120.2)Fault Detection andDiagnostic(FDD)requirements,have return,outsideair and relief damper leakage that meet Title24(section140.4and ASHRAE90.1--2013)requirements.EconoMi$er2.j Economizer with E NTHALPY sensing and barometric relief.ULTRA LOW LEAK Air Dampers—f Models with W7220controller meet CaliforniaTitle24(section120.2)Fault Detection andDiagnostic(FDD)requirements,have return,outsideair and relief damper leakage that meet Title24(section140.4and ASHRAE90.1--2013)requirements.EconoMi$er X.f Models with RTU Open controller meet CaliforniaTitle24(section120.2)Fault Detection andDiagnostic(FDD)requirements,have return,outsideair and relief damper leakage that meet Title24(section140.4and ASHRAE90.1--2013)requirements.EconoMi$er2.j Display Kit for V ariable Frequency Drive(VFD).Allows additional set up and diagnostics of the VFDcontroller.Kit includes display and cable.Kit can be used on size07thru26LC units.j Energy Demand System-wireless automated demand management and response controllersj Electric Heatersj Power exhaust-prop fan designj Roof curb-14inch(356mm)tallj Roof curb-24inch(610mm)tallj Adapter curb(available for sizes14--20only)j Barometric Relief Hood for Horizontal Economizer applicationsj Condenser hail guard-louvered stylej Phase monitor(loss of phase/phase reversal)j Time Guard II compressor anti--cycle protectionj4--inch filter track upgrade kitj Thermostats and Sensors–48LC size14--26units require a three--stage coolingthermostat to perform at the listed operating efficiencies.Carrier offers a Honeywell branded T7350D3Cool/3Heat Commercial Programmable Thermostatwhich provides the following features:S7--day programmableS365--day clock with holiday programmingS Automatic Daylight Saving Time adjustmentS Backlit displayS Changeover selections:automatic or manualS Fan configurable:continuous or intermittent duringoccupiedEconomizer Sensorsj Single dry bulb controlj Single enthalpy controlj Differential enthalpy controlj CO2-wall mountedj CO2-duct mountedj CO2-unitmountedC E R T I F I ED D I ME N S I O N 50L C 14C 1306C E R T I F I ED D I ME N S I O N 50L C 14C 13061C E R T I F I ED D I ME N S I O N 50L C 14C 13062C E R T I F I ED D I ME N S I O N 50L C 17,2C 13035C E R T I F I ED D I ME N S I O N 50L C 17,2C 13036C E R T I F I ED D I ME N S I O N 50L C 17,2C 13037C E R T I F I ED D I ME N S I O N 50L C 24,26C 13041C E R T I F I ED D I ME N S I O N 50L C 24,26C 13042C E R T I F I ED D I ME N S I O N 50L C 24,26C 13043ROOF CURB DETAILS—SIZE 14UNITSC13054。
配电电器1 产品概述3 型号及含义2 正常使用条件TG M 2 L C — □ □/3N/□无:V1.x 版控制器(液晶型);Y1:V2.x 版控制器(液晶型),Y2:V3.x 版控制器(液晶型);Y3:V4.x 版控制器(液晶型),S1:Vs.x 版控制器(数码型)极数:三极四线(3P+N)额定极限短路分断能力级别(L:标准型;M:较高分断型)壳架等级额定电流 具有自动重合闸功能具有剩余电流保护功能设计代号塑料外壳式断路器企业特征代号TGM2LC 系列剩余电流保护断路器TGM2LC 系列剩余电流保护断路器(以下简称断路器),是本公司为满足城乡电网及其他各类所需剩余电流重合闸功能而开发的产品。
该系列断路器适用于交流50Hz,额定电压至400V,额定绝缘电压800V 的三相四线中性点直接接地的低压电网。
断路器有125A、250A、400A、630A、800A 五个壳架等级,整定电流从65A 至800A,额定剩余动作电流从50mA 至1000mA,具有过载保护、短路保护、剩余电流保护、过压保护、欠压保护、缺相保护及重合闸等功能。
产品延伸光伏专用系列、费控电能表专用系列。
断路器按分断能力(Icu)高低分为L 型(标准型)和M 型(较高分断型)两种。
断路器符合的标准:GB/T 14048.1 《低压开关设备和控制设备 第1部分:总则》GB/T 14048.2(IEC 60947-2) 《低压开关设备和控制设备 第2部分:断路器》(1) 周围空气温度:-5℃~+40℃;(2) 安装地点的海拨不超过2000m;(3) 安装地点的空气相对湿度在+40℃时不超过50%,在较低的温度下可以允许有较高的相对湿度,例如在+20℃时可以达到90%。
对由于温度变化偶尔产生的凝露应采取防护措施;(4) 污染等级:3级;(5) 断路器的安装类别为Ⅲ;(6) 断路器应安装在无爆炸危险和无导电尘埃、无足以腐蚀金属和破坏绝缘的地方;(7) 断路器应安装在没有雨雪侵袭的地方;(8) 安装场所的外磁场在任何方向不超过地磁场的5倍。