Product DataNOTE : Image for illustration purposes only. Actual model may differ slightly.TABLE OF CONTENTSPAGEMODEL NUMBER NOMENCLATURE 3.................STANDARD FEATURES AND ACCESSORIES 4...........DIMENSIONS 5......................................CLEARANCES 7.....................................SPECIFICA TIONS PATIBILITY 8...................................APPLICATION DATA 9................................WIRING 10..........................................WIRING DIAGRAMS 12...............................GUIDE SPECIFICATIONS 13...........................INDUSTRY LEADING FEATURES / BENEFITSA PERFECT BALANCE BETWEENBUDGET LIMITS, ENERGY SAVINGS AND COMFORT.The 40MBCQ series ductless systems are a matched combination of an outdoor condensing unit and an indoor fan coil unit connected only by refrigerant tubing and wires.The in−ceiling cassette fan coils are ideal for retrofit ormodernization projects where a false ceiling is available. This selection of fan coils permits inexpensive and creative solutions to design problems such as:S Add−ons to current space (an office or family room addition)S Special space requirementsS When changes in the load cannot be handled by the existing systemS When adding air conditioning to spaces that are heated by hydronic or electric heat and have no ductwork SHistorical renovations or any application wherepreserving the look of the original structure is essential.The ideal compliment to your ducted system when it is impractical or prohibitively expensive to use ductwork. These compact indoor fan coil units take up very little space in the room and do not obstruct windows. The fan coils are attractively styled to blend with most room decors.Advanced system components incorporate innovative technology to provide reliable cooling performance at low sound levels.LOW SOUND LEVELSWhen noise is a concern, the ductless systems are the answer. The indoor units are whisper quiet. There are no compressors indoors, either in the conditioned space or directly over it, and there is none of the noise usually generated by air being forced through ductwork.SECURE OPERATIONIf security is an issue, outdoor and indoor units are connected only by refrigerant piping and wiring to prevent intruders from crawling through ductwork. In addition, since outdoor units can be installed close to an outside wall, coils are protected from vandals and severe weather.FAST INSTALLATIONThis compact ductless system is simple to install. A mounting bracket is standard with the indoor units and only wire and piping needs to run between indoor and outdoor units. These units are fast and easy to install ensuring minimal disruption to customers in the home or workplace. This makes the ductless systems the equipment of choice, especially in retrofit situations. SIMPLE SERVICING AND MAINTENANCE Removing the top panel on outdoor units provides immediate access to the control compartment, providing a service technician access to check unit operation. In addition, the draw−thru design of the outdoor section means that dirt accumulates on the outside surface of the coil. Coils can be cleaned quickly from inside using a pressure hose and detergent.On all indoor units, service and maintenance expense is reduced due to easy−to−use cleanable filters. In addition, these cassette systems have extensive self−diagnostics to assist in troubleshooting.BUILT − IN RELIABILITYDuctless system indoor and outdoor units are designed to provide years of trouble−free operation.The in−ceiling cassette units include protection against freeze−up and high evaporator temperatures on heat pumps.The condensing units on heat pumps are protected by a three minute time delay before the compressor starts the over−current protection and the high temperature protection.INDIVIDUAL ROOM COMFORTMaximum comfort is provided because each space can be controlled individually based on usage pattern. The air sweep feature provided permits optimal room air mixing to eliminate hot and cold spots for occupant comfort. In addition, year−round comfort can be provided with heat pumps.ECONOMICAL OPERATIONThe ductless system design allows individual room heating or cooling when required. There is no need to run large supply−air fans or chilled water pumps to handle a few spaces with unique load patterns. In addition, because air is moved only in the space required, no energy is wasted moving air through ducts.EASY−TO−USE CONTROLSThe in−ceiling cassette has microprocessor−based controls to provide the ultimate in comfort and efficiency. The user friendly wireless remote control provides the interface between user and the unit.FACTORY INSTALLED CONDENSATE LIFT PUMPCustomizing these ductless systems to your application is easily accomplished. The factory installed condensate lift pump on the cassette fan coil unit provides installation flexibility.OPTIONAL WIRED CONTROLLERAGENCY LISTINGSAll systems are listed with AHRI (Air Conditioning, Heating & Refrigeration Institute), and ETL.23MODEL NUMBER NOMENCLATUREQ C -SYSTEM TYPE Q = HEAT PUMP INDOOR FAN COIL TYPE C = CASSETTENOT USEDINDOOR UNIT40MB 30940 = FAN COIL UNITMB = MODELVOLTAGE3 = 208/230-1-60NOMINAL CAPACITY 09 - 3/4 TON 12 - 1 TON18 - 1-1/2 TONS 24 - 2 TONS36 - 3 TONS 48 - 4 TONSNOT USED- -Use of the AHRI Certified TM Mark indicates a manufacturer’s participation in theprogram For verification of certification for individual products, go to.4STANDARD FEATURES AND ACCESSORIESS Standard A AccessoryACCESSORIESINDOOR UNIT ACCESSORIESGrilleTo maximize shipping efficiency , the grille for the in−ceiling cassette is set up as an accessory.NOTE: Grille is required.5DIMENSIONSFig. 1 – Indoor Unit (Sizes 9−18)6DIMENSIONS − (CONT)32A B C DCapacity (Btu/h)24K mm 160 75 205 50 inch 6.30 2.95 8.07 1.97 36K mm 160 95 245 60 inch 6.30 3.74 9.65 2.36 48Kmm 160 95 287 60 inch 6.30 3.74 11.30 2.36Fig. 2 – Indoor Unit (Sizes 24−48)CLEARANCESFig. 3 – Indoor Unit Clearance7SPECIFICATIONSNOTE: Performance may vary based on the compatible outdoor units. See respective pages for performance data. COMPATIBILITYNOTE: Backward compatible with 38MAQ Single Zone and 38MGQ Multi−zone Systems.8APPLICATION DATAUNIT SELECTIONSelect equipment to either match or handle slightly less than the anticipated peak load. This provides better humidity control, fewer unit cycles, and less part−load operation.For units used in spaces with high sensible loads, base equipment selection on the unit sensible load, not on the total anticipated load. Adjust for anticipated room wet bulb temperature to avoid undersizing the equipment.UNIT MOUNTING (INDOOR)Refer to unit Installation Instructions for further details.Unit leveling − For reliable operation, units should be level in all planes. Align and level the unit by adjusting the nuts and lock−nuts on the threaded hangers.Clearance − A minimum of 12 inches (304.8 mm) of clearance is required in the false ceiling.Unit location − Placing the unit in the center of the room provides the best air circulation and comfort. The unit return and discharge should not be obstructed by anything which may cause unit short cycling or air recirculation.Installation Template − Fan coil units are supplied with a cardboard template to help match the position of the hangers, refrigerant lines, condensate drain pipe and power supply cable. UNIT MOUNTING (OUTDOOR)Refer to the unit’s Installation Instructions for further details. Do not install the indoor or outdoor units in a location with special environmental conditions. For those applications, contact your ductless representative.SUPPORTAdequate support must be provided to support the weight of all fan coils. Refer to the Physical Data section for fan coil weights, and the base unit dimensional drawings for the location of the mounting brackets.SYSTEM OPERATING CONDITIONSDRAIN CONNECTIONSInstall drains to meet local sanitation codes. The in−ceiling cassette is supplied with a condensate lift pump that is capable of lifting the water 29.5in (750mm) above the top of the unit. A downward sloped condensate drain pipe can be used to dispose of water. REFRIGERANT LINESGeneral refrigerant line sizing:1.The outdoor units are shipped with a full charge of R410Arefrigerant.2.Refrigerant lines should not be buried in the ground. If it isnecessary to bury the lines, not more than 36−in (914 mm)should be buried. Provide a minimum 6−in (152 mm)vertical rise to the service valves to prevent refrigerantmigration.3.Both lines must be insulated. Use a minimum of 1/2−in.(12.7 mm) thick insulation. Closed−cell insulation isrecommended in all long−line applications.4.Special consideration should be given to isolatinginterconnecting tubing from the building structure. Isolatethe tubing so that vibration or noise is not transmitted intothe structure.9WIRINGAll wires must be sized per NEC (National Electrical Code) or CEC (Canadian Electrical Code) and local codes. Use Electrical Data table MCA (minimum circuit amps) and MOCP (maximum over current protection) to correctly size the wires and the disconnect fuse or breakers respectively.Recommended Connection Method for Power and Communication Wiring:The main power is supplied to the outdoor unit. The field supplied 14/3 stranded wire with ground with a 600 volt insulation rating, power/communication wiring from the outdoor unit to indoor unit consists of four (4) wires and provides the power for the indoor unit. Two wires are line voltage AC power, one is communication wiring (S) and the other is a ground wire. Wiring between indoor and outdoor unit is polarity sensitive. The use of BX wire is NOT recommended.If installed in a high Electromagnetic field (EMF) area and communication issues exists, a 14/2 stranded shielded wire can be used to replace L2 and (S) between outdoor unit and indoor unit landing the shield onto ground in the outdoor unit only.CONTROL SYSTEMThe indoor unit is equipped with a microprocessor control to perform two functions:1.Provide safety for the system2.Control the system and provide optimum levels of comfortand efficiency.The main microprocessor is located on the control board of the fan coil unit (outdoor units have a microprocessor too) with thermistors located in the fan coil air inlet and on the indoor coil. Heat pump units have a thermistor on the outdoor coil. These thermistors monitor the system operation to maintain the unit within acceptable parameters and control the operating mode. WIRELESS REMOTE CONTROLFig. 4 – Wireless Remote Control1.A wireless remote control is supplied for system operationof all in−ceiling cassette units.2.Each battery operated wireless (infrared) remote controlmay be used to control more than one unit.WIRED REMOTE CONTROL (OPTIONAL) Part Numbers (P/N):S KSACN0101AAA (Timer Function)S KSACN0501AAA (7 Day Programmable)1.Optional wired remote controller used for system operationof all in−ceiling cassette units.2.Kit includes a wired remote controller and a connectingcable.NOTE: Extension wire available through RCD (KSACN0101AAA Part Number: 17401204001601; KSACN0501AAA Part Number: 17401204000769).3.Connect the wire terminal between the remote controllerand the indoor unit.4.Display in _F or _C and temperature increments every 1_For every 1_C.Fig. 5 – KSACN0101AAA (Timer Function)Fig. 6 – KSACN0501AAA (7 Day Programmable)10SOUND PRESSURE TESTING METHODFig. 7 – Sound Pressure Testing MethodWIRING DIAGRAMSFig. 8 – Wiring Diagram (Sizes 9K−24K)Fig. 9 – Wiring Diagram (Size 36K−48K)GUIDE SPECIFICATIONS INDOOR IN−CEILING CASSETTE DUCTLESS UNITS Size Range: 3/4 to 4 Ton Nominal Cooling and Heating CapacityModel Number: 40MBCQPART 1 − GENERAL1.01 System DescriptionIndoor, in−ceiling cassette, direct−expansion fan coils are matched with a heat pump outdoor unit.1.02 Agency ListingsUnit are rated per AHRI Standards 210/240 and listed in the AHRI directory as a matched system.1.03 Delivery, Storage, And HandlingUnits are stored and handled per the unit manufacturer’s recommendations.1.04 Warranty (For Inclusion By Specifying Engineer)PART 2 − PRODUCTS2.01 EquipmentA.General:Indoor, direct−expansion, ceiling−mounted fan coil. Unit is complete with a cooling/heating coil, fan, fan motor, piping connectors, electrical controls, microprocessor control system, and an integral temperature sensing.B.Unit Cabinet: Cabinet is constructed of zinc−coated steel.Fully insulated discharge and inlet grilles are attractively styled, high−impact polystyrene. Grille has hinges and can be opened to obtain access to the cleanable filters, indoor fan motor and control box.C.FANS:1.The fan is a centrifugal direct−drive blower type with an airintake in the center of the unit and a discharge at theperimeter. An automatic, motor−driven vertical air sweep isprovided standard. Automatic motor−driven louvers areprovided standard and are adjustable for a 2, 3 or 4−waydischarge.2.The air sweep operation is user selectable.D.Coil:The coil is a copper tube with aluminum fins and galvanized steel tube sheets. Fins are bonded to the tubes by mechanical expansion and specially golden hydrophilic pre−coated for enhanced wet−ability. A drip pan under the coil has a factory installed condensate lift pump and a drain connection for a hose attachment to remove condensate.E.Motors:Motors are open drip−proof, permanently lubricated ball bearing with inherent overload protection. Fan motors are 7−speed.F.Controls:Controls consist of a microprocessor−based control system which controls the space temperature, determines the optimum fan speed, and runs self diagnostics. The temperature control range is 62_F to 86_F (17_C to 30_C) in increments of 1_F or 1_C, and has a 46_F Heating Mode (Heating Setback). The wireless remote controller, has the ability to act as the temperature sensing location for room comfort.The unit shall have the following functions as a minimum:1.An automatic restart after a power failure at the sameoperating conditions as at failure.2.A timer function to provide a minimum 24−hour timercycle for the system’s Auto Start/Stop.3.Temperature−sensing controls sense the return airtemperature.4.Indoor coil freeze protection.5.Wireless infrared remote control to enter set points andoperating conditions.6.Automatic air sweep control to provide on or off activationof air sweep louvers.7.Dehumidification mode which provides increased latentremoval capability by modulating system operation and setpoint temperature.8.A fan−only operation to provide room air circulation whenno cooling is required.9.Diagnostics to provide continuous checks of the unitoperation and warn of possible malfunctions. Any errormessages are displayed at the unit.10.The fan speed control is user−selectable: high, medium,low, or microprocessor controlled automatic operationduring all operating modes.11.Automatic heating−to−cooling changeover in the heat pumpmode. Control includes deadband to prevent rapid modecycling between heating and cooling.12.Indoor coil high temperature protection is provided to detectexcessive indoor discharge temperature when unit is in theheat pump mode.G.Filters:The unit has a filter track with factory−supplied cleanable filters.H.Electrical Requirements:The indoor fan motor operates on 208−230V on model sizes 09−48, as specified. Power is supplied from the outdoor unit.I.Operating Characteristics:The 40MBCQ system has a minimum SEER (Seasonal Energy Efficiency Ratio) and HSPF at AHRI conditions, as listed on the specifications table.J.Refrigerant Lines:All units should have refrigerant lines that can be oriented to connect from the left, right or back of unit. Both refrigerant lines must be insulated.Copyright 2018 Carrier Corp. D 7310 W. Morris St. D Indianapolis, IN 46231 . Edition Date: 04/18Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.Catalog No: 40MBCQ-02PD Replaces: 40MBCQ-01PD。
MAKING MODERN LIVING POSSIBLE操作说明VLT® 软启动器 - MCD500目录1 安全性51.1 安全性52 简介62.1.1 功能列表62.1.2 类型代码73 安装83.1 机械安装83.2 尺寸和重量94 电气安装104.1.1 控制线路104.1.2 控制端子104.1.3 远程输入114.1.4 串行通讯114.1.5 地线端子114.1.6 电力端接124.1.7 电动机连接134.2 串联式安装134.2.1 串联式安装,内部旁路134.2.2 串联式安装,无旁路134.2.3 串联式安装,外部旁路144.3 内部三角形安装144.3.1 内部三角形安装,内部旁路154.3.2 内部三角形安装,无旁路154.3.3 内部三角形安装,外部旁路164.4 电流额定值164.4.1 串联(旁路型)174.4.2 串联(无旁路/连续)174.4.3 内部三角形连接(旁路)184.4.4 AC-53 额定值(对于旁路工作)184.4.5 内部三角形连接(无旁路/连续)194.4.6 AC-53 额定值(对于恒定工作)194.5 最小和最大电流设置204.6 旁路接触器204.7 主接触器204.8 断路器204.9 功率因数修正214.10 熔断器214.10.2 Bussman 熔丝 - 方形 (170M)224.10.3 Bussman 熔丝 - 英式 (BS88)234.10.4 Ferraz 熔丝 - HSJ244.10.5 Ferraz 熔丝 - 北美式 (PSC 690)254.10.6 经 UL 认证的熔丝 - 短路额定值264.11 示意图274.11.1 内部旁路型号274.11.2 无旁路型号285 应用示例295.1 电动机过载保护295.2 AAC 自适应加速控制295.3 启动模式305.3.1 恒定电流305.3.2 电流斜坡305.3.3 AAC 自适应加速控制305.3.4 快速启动315.4 停止模式315.4.1 惯性停车315.4.2 TVR 软停止315.4.3 AAC 自适应加速控制315.4.4 制动325.5 点动操作325.6 内部三角形操作335.7 典型启动电流345.8 带主接触器的安装355.9 带旁路接触器的安装365.10 紧急运行操作375.11 辅助跳闸电路385.12 软制动395.13 两速电动机406 更改426.1 操作和 LCP426.1.1 工作模式426.2 控制方法436.3 本地控制按钮446.4 显示446.4.1 温度监视屏幕 (S1)446.4.2 可编程屏幕 (S2)446.4.3 平均电流 (S3)446.4.4 电流监视屏幕 (S4)446.4.5 频率监视屏幕 (S5)446.4.6 电动机功率屏幕 (S6)446.4.7 上次启动信息 (S7)446.4.8 日期和时间 (S8)456.4.9 SCR 传导性条形图456.4.10 性能图457 编程467.1 访问控制467.2 快捷菜单477.2.1 快捷设置477.2.2 应用设置487.2.3 日志497.3 主菜单497.3.1 参数497.3.2 参数快捷方式497.3.3 参数列表507.4 主电动机设置517.4.1 制动527.5 保护527.5.1 电流失衡527.5.2 欠流527.5.3 瞬时过流527.5.4 频率跳闸537.6 输入537.7 输出547.7.1 继电器 A 延时547.7.2 继电器 B 和 C547.7.3 低电流标志和高电流标志557.7.4 电动机温度标志557.7.5 模拟输出 A557.8 启动/停止计时器567.9 自动复位567.9.1 自动复位延时567.10 辅电动机设置577.11 显示587.11.1 用户可编程屏幕587.11.2 性能图597.12 受限参数597.13 保护操作607.14 工厂参数608 工具618.1 设置日期和时间618.2 载入/保存设置618.3 将热模型复位618.4 保护模拟618.5 输出信号模拟628.6 数字 I/O 状态628.7 温度传感器状态628.8 报警记录628.8.1 跳闸日志628.8.2 事件日志638.8.3 计数器639 疑难解答649.1 跳闸消息649.2 一般性故障6710 规格6910.1 附件7010.1.1 通讯模块7010.1.2 PC 软件7110.1.3 护手罩套件7111 母线调整程序 (MCD5-0360C - MCD5-1600C)721安全性1.1 安全性您在阅读本手册时会遇到各种需要特别注意的符号。
直流无刷电机霍尔位置传感器电磁干扰机理与试验研究马宁;吕晶薇;高小松;刘洋;孙利【摘要】直流无刷电机在工业中应用广泛,其采用电子换相装置,具有维修费用低、寿命长、效率高和安全性好的特点,直流无刷电机主要的电子换向装置是霍尔式转速传感器.霍尔位置传感器由于其体积轻巧、使用方便已经成为直流无刷电机配备的主要传感器,可实现电机转动位置的测量,进而控制电机的换向.针对霍尔位置传感器工作时易受到电机绕组产生的电磁场干扰的问题,通过对霍尔传感器空间安装位置和绕组相电流的对比试验,研究不同磁场强度下,霍尔传感器转动位置测量的偏差,以及对换向时序的影响,找出影响直流无刷电机工作的因素为霍尔传感器安装位置和相电流控制,并根据试验结果提出减少干扰的方法,从而防止电机换向时由于干扰导致时序紊乱而引发的电机失控现象.【期刊名称】《新技术新工艺》【年(卷),期】2019(000)007【总页数】5页(P51-55)【关键词】直流无刷电机;霍尔传感器;电机绕组;电磁场;干扰;时序紊乱【作者】马宁;吕晶薇;高小松;刘洋;孙利【作者单位】北京卫星制造厂有限公司,北京 100094;北京卫星制造厂有限公司,北京 100094;北京卫星制造厂有限公司,北京 100094;北京卫星制造厂有限公司,北京100094;北京卫星制造厂有限公司,北京 100094【正文语种】中文【中图分类】TH16直流电机(Direct Current machine)可以实现直流电能和机械能互相转换。
其优点包括维修费用低、运转距离较大、启动特性和调速特性优秀、调速性能好、调速范围广且平滑、过载能力较强和受电磁干扰影响小。
因此直流电机在各领域都有着广泛的应用。
早期的直流电机通过电刷进行换向,被称为直流有刷电机,但由于电刷在换向时会产生电火花,既造成了换向器的电腐蚀,还是无线电干扰源,会对周围的电器设备带来有害影响。
电机的容量越大、转速越高,问题就越严重。
因此安全可靠性使电机的使用受到了限制。
* *19XL 冷水机组操作中英文比较* LID 显示页典范* (以下表中显示页均为PSIO 模块 08 版本 [19XL-2SS] 中的显示页 )注: 1 、任何给准时间内LID 屏幕上只出现12 行信息。
按NEXT或PREVIOUS,光标显示一个点或许查察目前屏幕前一页或后一页内容。
2、能够依据要求采纳公制或英制单位。
1 -状态 01 显示页从 LID 开端页进入状态01 页:1、按MENU。
2 、按STATUS ( 状态 01 会光明显示 )。
3 、按SELECT。
内容 (英文 )内容 (中文 )参照点名称范围单位实设值(报警记录 )Control Mode控制模式复位,停机,本机, CCN MODERun Status运行状态时间用完,再循环,开机,STATUS控制加负载,运行,需求量,优先控制,关系,不正常,减压。
Occupied?占用?NO/YES OCC Alarm State报警状态正常/报警ALM Chiller State/Stop冷水机组开机 / 关机关 / 开CHIL_S_S Base Demand Limit基本需求量极限40 -100%DLM Active Demand Limit有效需求量极限40 -100%DEL_LIM Compressor Motor压缩机电机负载0 -999%CA_LLoadCurrent电流0 -999%CA_PAmps安培0 -999AMPS CA_A Target Guide Vane Pos目标导叶地点0 -100%GV_TRG Actual Guide Vane Pos实质导叶地点0 -100%GV_ACT Water/Brine: Set Point水/ 盐水 : 整定点-12.2 -℃SP Control Point控制点-12.2 -℃LCW_STPT Enteing Chilled Water冷水进水温度-40 -118℃ECW Leaving Chilled Water冷水出水温度-40 -118℃LCW Enteing Condenser冷却水进水温度-40 -118℃ECDW WaterLeaving Condenser冷却水出水温度-40 -118℃LCDW WaterEvaporator Refrig蒸发器制冷剂温度-40 -118℃ERTTempEvaporator Pressure蒸发器压力-46 -2896kPa ERP* *Condenser冷凝器制冷剂温度-40 -118℃CRT TemperatureCondenser Pressure冷凝器压力-46 -2896kPa CRP Discharge排气温度-40 -118℃CMPD TemperatureBearing Temperature轴承温度-40 -118℃MTRB Motor Winding Temp电机绕组温度-40 -118℃MTRWOil Sunp Temperature油箱温度-40 -118℃OILT油压传感器-46 -2896kPa OILPOil Pressure油压-46 -2896kPa OILPD Line Voltage: Percent电压 : 百分比0-999%V_P Actual实质值0-9999VOLTS V_A Remote Contacts遥控接触点输入OFF/ON REMCON InputTotal Compressor压缩机重启动数0-65535C_STARTS StartsStarts In 12 Hours12 小时内启动数0-8STARTS Compressor Ontime压缩机开机时间0-小时C_HRS Served Ontime服务进行时间0-32767小时S_HRS Compressor Motor压缩机电机功率0-9999kW CKWKW* *2 -状态02 显示页要从 LID 开端页进入状态1、 按 MENU。