辽宁沈阳IBM服务器周报12年1月第3版
- 格式:pdf
- 大小:192.90 KB
- 文档页数:3
IBM Spectrum Archive Single Drive Edition (SDE) Version 2.4Support Matrix (As of September, 2019)This document provides the information about the supported hardware and software configurations for the latest version of IBM Spectrum Archive software, as the complement of IBM System Storage In-teroperation Center (SSIC) system at:/systems/support/storage/ssic/interoperability.wssRequest for Price Quotations (RPQ)If a desired configuration is not listed in this document, an RPQ should be submitted to IBM to request approval. To submit an RPQ, contact your local IBM Storage Specialist or Business Partner.Legal DisclaimerThe information provided in this document is provided "AS IS" without warranty of any kind, including any warranty of merchantability, fitness for a particular purpose, interoperability or compatibility. IBM does not provide service or support for the non-IBM products listed. For support issues regarding non-IBM products, please contact the manufacturer of the product directly. This information could include tech-nical inaccuracies or typographical errors. IBM does not assume any liability for damages caused by such errors as this information is provided for the reader's convenience only.1. Reference InformationIBM Spectrum Archive web page:/systems/storage/tape/ltfs/index.htmlIBM Spectrum Archive SDE on-line user’s guide:/support/knowledgecenter/STQNYLIBM Spectrum Archive software fix download site (Fix Central):/support/fixcentral/12. Supported Hardware ConfigurationTested Tape Drives:Linear Tape-Open (LTO) Tape DriveIBM LTO-5 half-height tape driveIBM LTO-5 full-height tape driveIBM LTO-6 half-height tape driveIBM LTO-6 full-height tape driveIBM LTO-7 half-height tape driveIBM LTO-7 full-height tape driveIBM LTO-8 half-height tape driveIBM LTO-8 full-height tape driveIBM Enterprise Tape DriveIBM TS1140 enterprise tape driveIBM TS1150 enterprise tape driveIBM TS1155 (3592 55F or 55G) enterprise tape driveIBM TS1160 enterprise tape driveSupported Host Interface:SAS/Fiber Channel HBA (Linux, Windows):Search the supported HBA on the SSIC with both tape drive and OS to the key.SAS/Fiber Channel HBA (Mac):ATTO ExpressSAS H6F0ATTO ExpressSAS H680ATTO ExpressSAS H644ATTO Thunderlink SH 3128USB Ports:USB 3.0 Ports on Intel x86 compatible PC and MacThunderbolt Ports:Thunderbolt Ports on Mac, using 3rd party Thunderbolt-to-SAS adapterFor other hardware configuration and interoperability for the IBM Spectrum Archive SDE on IBM branded tape drives, such as host bus adapters (HBA) and SAN switch, please search the information on the SSIC.For OEM branded tape drives, ask your supplier about the interoperability and the availability of latest drive firmware23. IBM Spectrum Archive Single Drive Edition Version 2.4.1.2 for Linux (Build 10254)Supported OS:Red Hat Enterprise Linux (RHEL)7.2 (x86_64)7.3 (x86_64 and ppc64le)7.4 (x86_64 and ppc64le)7.5 (x86_64 and ppc64le)7.6 (x86_64 and ppc64le)Prerequisite Software:NoneNote: The installation of IBM Tape Device Driver is no longer required.34. IBM Spectrum Archive Single Drive Edition Version 2.4.1.2 for Mac OS X (Build 10253)Supported OS:OS XEl Capitan 10.11macOSSierra 10.12High Sierra 10.13Mojave 10.14Prerequisite Software:ICU Framework 4.8.1.1 (Available in the IBM Spectrum Archive SDE software package)FUSE for macOS 3.6.3 (Available in the IBM Spectrum Archive SDE software package)45. IBM Spectrum Archive Single Drive Edition Version 2.4.1.2 for Windows 64-bit (Build10254)Supported OS:Microsoft Windows 8.1Microsoft Windows 10 (Anniversary Update or later)Microsoft Windows Server 2012 R2Microsoft Windows Server 2016Prerequisite Software:Microsoft Visual C++ 2010 Redistributable Package (x64)Microsoft .NET Framework 45。
X3500M3(7380)X3400M3(7379,7378)X3250M3(4251,4252)X3200M3(7327,7328)四.哪些服务器集成了VFA II?A:除了标准PCIe的VFA II Option(49Y7950)外,x3850X5/x3950X5/x3690X5上还标配了Integrated VFAII(SBB: 49Y7940)。
这三种机型上都有一个专用的槽位,只能用来安装Integrated Emulex VFAII(49Y7940)。
Integrated VFA II(SBB: 49Y7940)和VFA II Option (option PN: 49Y7950)在功能上完全一致。
因此,您可以选择预装了Integrated Emulex VFA II的服务器型号,也可以通过安装VFA II Option Card 的方式,来使用Emulex 10Gb VFA II for IBM System x。
五.VFA II for x和for Blade的比较?A:VFA II for System x和VFA II for BladeCenter都是基于Emulex BladeEngine 3(BE3) 芯片,功能上一致。
都是2个10Gb物理端口,支持多达8个vNIC,通过付费升级的方式支持FCoE和iSCSI功能(当启用FCoE 或iSCSI功能时,每个物理端口虚拟的4个vNIC中有一个作为FCoE或iSCSI连接,其余三个仍为vNIC)。
VFA II for System x的vNIC管理与设置和VFA II for BladeCenter相同。
VFA II for System x的FCoE License(49Y4274)已经于2011/12/9 GA, iSCSI License即将发布。
而VFA II for BladeCenter的FCoE/iSCSI License都已经发布(49Y4265)。
IBM服务器、存储等设备维保服务项目需求一、服务内容、方式和要求(一)服务内容1、服务时限:2014年1月1日至2014年12月31日。
2、服务范围,提供下述设备的维保服务:◆ P系列小型机89台(含HA)。
◆ X系列PC服务器181台。
◆存储设备4套。
◆其他设备16台。
◆现场技术支持150小时。
详见设备列表及各设备的服务起止时间。
3、服务内容:服务提供方应根据设备列表中列明的小型机、PC服务器、存储设备和其他设备提供硬件保修服务和操作系统维护技术支持服务,通过对我会小型机系统和PC服务器环境定期进行规范化的预防性维护,提高小型机系统和PC服务器的可靠性和稳定性。
对存在问题及突发故障提供及时有效的技术支持、完善的解决方案和事后防范机制,减低故障对生产系统的影响,保证生产系统稳定运行。
具体包括:(1)提供7*24小时硬件设备维护服务,通过到故障现场进行维护或更换备件,保障我会小型机系统设备和PC服务器稳定运行。
(2)提供7*24小时系统软件维护服务和技术支持,包括操作系统、HACMP软件在内的系统软件故障诊断和系统恢复。
(3)提供系统故障记录分析(包括软件和硬件)和问题报告,解决系统隐患。
建立维护服务档案,记录系统配臵、维护记录等。
(4)对我会小型机和PC服务器等设备进行定期巡检和预防性维护,具体包括:A、每月一次的设备和操作系统健康检查。
B、提供系统补丁和硬件微码的合法升级服务,建立硬件微码及系统补丁的管理数据库,制订升级方案,协助我会实施升级工作。
C、协助我会完善系统备份及恢复方案。
D、提供小型机设备运行分析、性能评估和配臵调整服务,提高系统的可靠性、可用性和整体性能。
E、提供小型机设备容量分析和趋势预测服务,以提高系统容量评估的水平。
F、向我会提交详细的可用性和安全性分析报告,提交预防性维护策略报告。
G、定期提交预防性维护工作报告(5)现场技术支持提供150小时的现场技术支持,包括但不限于以下内容:DS4300/DS4400/DS8300存储划盘、服务器性能调优、技术方案制定和我会要求的其他服务等。
x产品技术支持信息周报(2014年五月第三版)【周报导读】一、X3850X6最多支持多少内存?二、X3950X6最多支持多少内存?三、X3250M5可以支持多少块硬盘?四、X3850X6标配什么网卡?五、X3850X6的PCI E插槽能否支持热插拔?六、CMM中如何改变计算节点的启动项?七、IO BOOK有哪几种?八、如何通过IMM安装操作系统?九、服务器CPU的基本功能?十、I NTEL超线程技术简介?【周报内容】一、X3850 X6最多支持多少内存?A: 使用RDIMMs: 配置4颗CPU时最多1.5 TB使用96x 16 GB RDIMMs 使用LRDIMMs:配置4颗CPU时最多6 TB 使用96x 64 GB LRDIMMs请参考以下红皮书:/Redbooks.nsf/RedbookAbstracts/tips1084.html二、X3950 X6最多支持多少内存?A: 使用RDIMMs:当配置8颗CPU时最多3TB使用192x 16 GB RDIMMs 使用LRDIMMs:当配置8颗CPU时最多12TB使用192x 64 GB LRDIMMs请参考以下红皮书:/Redbooks.nsf/RedbookAbstracts/tips1132.html三、X3250 M5 可以支持多少块硬盘?A: X3250 M5 可选的机型有:●Four 2.5-inch small form factor (SFF) SAS/SATA hot-swap drive bays●Eight 2.5-inch SFF SAS/SATA hot-swap drive bays●Four 2.5-inch SFF SAS/SATA simple-swap drive bays●Eight 2.5-inch SFF SAS/SATA simple-swap drive bays●Four 3.5-inch large form factor (LFF) SAS/SATA hot-swap drive bays●Four 3.5-inch LFF SATA simple-swap drive bays部分标配带M1115阵列卡或者N2115 HBA卡的机型可以添加选件00AL348 x3250 M5 HS 2.5" HDD 4 to 8 Upgrade Kit 升级到8块2.5寸硬盘,如果标配是H1110阵列卡的4块2.5寸硬盘机型不可以升级到8块硬盘,如下图所示:更多详细信息参考相关red book:/abstracts/tips1050.html?Open#disk_int四、X3850 X6标配什么网卡?A: 标配大部分的basemodel都是4个千兆网卡,也有标配带2个万兆的机型,具体情况参考下面表格:从上面表格可以看出,只有B3X的机型标配是Broadcom NetXtreme II ML2 Dual Port 10GbE SFP+的网卡,其他机型都市Intel I350-T4 ML2 Quad Port GbE Adapter (I350-AM4 based)。
A:x3650M3内存插槽及安装顺序如下:
内存配置规则:
◦每个CPU 3个内存通道
◦每个通道安装一条内存时,内存运行速度 1333MHz;
◦安装两条内存时, 运行速度1066MHz;
◦安装三条内存时,运行在800MHz
◦如为x5600 CPU 不两条内存时不降频
二.x3650M3硬盘如何配置?
A:硬盘配置规则如下:
背板连接效果图:
三.Setup Utility常见功能?
A:系统启动后,按F1进入。
查看系统信息
- 如关键产品信息
- 系统配置信息
更改系统参数
- CPU设置,如开启超线程,开启/关闭核心
- 设置可用内存条数
- I/O设置
- 电源策略
- 运行模式
- Legacy 支持遗留系统
- IMM 设置(包括IMM 网络配置,重设等)
- 安全设置
- 驱动设置
- 网络设置
四.如何使用Vmware嵌入式管理程序?
A:Vmware 嵌入式管理程序:
◦为集成虚拟化软件
◦USB Memory Key安装在SAS转接卡的USB系统管理程序接口中◦目前可支持的选择包括:
要开始使用嵌入式虚拟化软件,必须先将USB存储钥匙添加到Setup Utility的启动顺序中
五.M5016阵列卡介绍?
A:请参考下图介绍:
六.SAS线缆选件39R6529/39R6531的接口是什么规格?
A:接口规格是标准Mini-SAS (SFF-8088),如下图所示:
详细可参考红皮书内容:/abstracts/tips0824.html?Open
/abstracts/tips0844.html?Ope。
内存插法如下:二.x3755M3如何配置电源?A:服务器最多支持三个 1100 瓦热插拔电源。
如果服务器只为双CPU配备了一个电源或为四CPU配备了两个电源,那么您可以再安装一个额外的电源以增加冗余电源功能。
如果服务器上的最大负载低于 1100 瓦,而且其中的一个电源出现了问题,那么另一个电源可以满足电源需求。
冗余电源选件:49Y7342(描述:1100W redundant power supply for x3755M3)。
三.x3850X5上两个以上的CPU加几个49Y4379?A:x3850X5添加两个以上CPU时,只需要加一个49Y4379,该选件包含两个QPI卡。
四.x3850X5可否添加冗余电源?A:x3850X5大部分机型标配是双电源实现冗余;如果是特殊机型标配1个电源,可以添加第二个电源以提供冗余,选件号:59Y6139。
五.x3850X5如何安装win2003?A:根据官方测试的操作系统的兼容性列表,x3850X5不支持win2003,不建议安装。
windows操作系统兼容性列表:/systems/info/x86servers/serverproven/compat/us/nos/microsoft.html如果一定要安装win2003,只能尝试用USB软驱软盘加载阵列卡驱动来安装,不保证一定可以安装成功,也无法确保安装后系统的稳定性。
所需驱动如下:1、阵列卡驱动(根据阵列卡类型选择下面的驱动):集成阵列LSI驱动做软盘添加(开机自检是Ctrl+C的提示):/support/entry/portal/docdisplay?brand=5000008&lndocid=MIGR-5084949阵列卡驱动做软盘(开机自检是Ctrl+H的提示):/support/entry/portal/docdisplay?lndocid=MIGR-50821612、装完系统后系统下未知设备驱动链接:芯片组/support/entry/portal/docdisplay?lndocid=MIGR-5082466&brandind=5000008IMM/support/entry/portal/docdisplay?lndocid=MIGR-5083849&brandind=5000008网卡/support/entry/portal/docdisplay?lndocid=MIGR-5083635&brandind=5000008显卡/support/entry/portal/docdisplay?lndocid=MIGR-5084349&brandind=5000008万兆网卡/support/entry/portal/docdisplay?lndocid=MIGR-5082984&brandind=5000008六.1754A1X与17353LX的区别?A:主要区别如下:七.HX5如何安装内存?A:HX5共16个内存插槽,每个CPU对应8个内存插槽,安装方法如下:八.HX5的SSD、CIOV和CFFh的扩展卡能否同时上?A:可以同时上,请参考HX5的主板图:九.DS3500的Turbo有什么作用?A:DS3500添加Turbo Performance(PN:69Y2871)可以提升IOPS和带宽的性能。
在产品保修期后,为继续向用户提供高质星的使用保障和技术服务,用户可根据需要选择IBM的维护协议服务项目,继续向IBM购买高质臺的技术服务。
1.1非现场维护支持系统IBM公司将以IBM信息支持中心(800免费技术支持热线)和信息系统服务事业部观场设备维护维修)为服务支持体系提供售后服务。
服务内容包括:热线电话服务、E-Mail.远程诊断和现场服务四种方式。
"IBM就是服务"在全国31个城市提供免费电话支持;信息支持中心的技术服务人员会在24小时内回复客户电话。
信息支持中心的规模和投入1.1.1信息支持中心的实力和承诺作为IBM在中国最重要的投资项目,中心集合各种先逬技术,采取综合管理措施,以确保信息服勢中心高效运作。
不仅于此,还有数百名训练有素的技术专家为您解决难题。
更有全球IBM的世界级专家随时调用。
另外,IBM分布在全球的其他信息支持中心也可通过网络系统对IBM中国信息支持中心提供支援。
1.1.2信息支持中心提供的服务(1) 中国信息支持中心为客户、合作伙借是供售前、售中、售后,从信息推广到技术支持的全方位服务,如下图:(2)信息支持中心的架构IBM中国信息支持中心整和了IBM的市场推广中心,客户关系中心,技术支持中心,产品支持服务中心等部门。
市场推广中心和客户关系中心主要负责市场信息推广;通过各种通讯方式与顾客建立联系,提供最新产品信息;制订市场计划;对IBM已装机客户提供走期行业信息服务,满足不同行业客户对IBM产品和解决方案的咨询需求。
并受理客户投诉事宜。
技术支持中心针对客户和业务伙伴的技术问题指派技术专家,提供IBM全线产品远程和技术支持,包括:S/390、P系列、AS/400. PC、网络与软件、打印机等。
为客户提供售前产品技术问答及系统配置检查、解答售后技术安装问题。
并提供跨平台的系统支持。
产品支持服务中心通过热线为IBM的工程技术人员提供技术支持和服务。
确保工程进展顺利,节省用户宝贵时间。
辽宁沈阳兴云,专业IBM服务器经销商。
186-024-32145
周报内容:
一.7143 base model的选用
A:关于x3850 X5(7143xxx) base model 的选用如下:
1. 7143B1C是比较简配的型号,其中只配了两颗E7-4807处理器、一个内存板、一个电源、没有RAID卡、没有Emulex 10Gb。
但是并不意味着,这个简配的型号可以出货。
2. 建议选用7143B2C做CTO, B2C 以上的型号配置比较像7145 的base model,如两颗处理器,两个内存板,4x4GB内存,RAID1015,两个电源,一个Emulex 10Gb card。
3. 在做配置时,请尽量使用SSCT。
4. 请注意Emulex 10GbE 如果加SFP+模块时,请选用PN: 49Y8578 每个口需要1个(这个选择是最经济的)。
二.VFA II for System x产品编号
A:产品编号:
三.VFA II适用于哪些服务器
A:VFA II Option (IBM PN: 49Y7950)是标准PCIe格式,可用在所有的System x机架服务器或塔式服务器上。
具体列表如下(资料来源:ServerProven):
X3850X5/x3950X5(7143)
X3755M3(7164)
X3690X5(7147)
X3650M3(7945)
X3630M3(7377)
X3620M3(7376)
X3550M3(7944)
X3500M3(7380)
X3400M3(7379,7378)
X3250M3(4251,4252)
X3200M3(7327,7328)
四.哪些服务器集成了VFA II
A:除了标准PCIe的VFA II Option(49Y7950)外,x3850X5/x3950X5/x3690X5上还标配了Integrated VFA II(SBB: 49Y7940)。
这三种机型上都有一个专用的槽位,只能用来安装Integrated Emulex VFA II(49Y7940)。
Integrated VFA II(SBB: 49Y7940)和VFA II
Option (option PN: 49Y7950)在功能上完全一致。
因此,您可以选择预装了Integrated Emulex VFA II的服务器型号,也可以通过安装VFA II Option Card的方式,来使用Emulex 10Gb VFA II for IBM System x。
五.VFA II for x和for Blade的比较
A:VFA II for System x和VFA II for BladeCenter都是基于Emulex BladeEngine 3(BE3) 芯片,功能上一致。
都是2个10Gb物理端口,支持多达8个vNIC,通过付费升级的方式支持FCoE和iSCSI功能(当启用FCoE或iSCSI功能时,每个物理端口虚拟的4个vNIC中有一个作为FCoE或iSCSI连接,其余三个仍为vNIC)。
VFA II for System x的vNIC管理与设置和VFA II for BladeCenter相同。
VFA II for System x的FCoE License(49Y4274)已经于2011/12/9 GA, iSCSI License即将发布。
而VFA II for BladeCenter的FCoE/iSCSI License都已经发布(49Y4265)。
六.VFA II目前支持哪些协议
A:VFA II for System x目前可以支持vNIC和FCoE功能,iSCSI License即将发布。
七.VFA II有几个物理端口
A:Emulex VFA II for System x有2个物理端口,标配不带SFP+模块。
可以选择SFP+ Transceiver或者DAC。
八.VFA II与其他10Gb卡有什么优势
A:Emulex VFA II是IBM System x服务器上唯一支持在物理端口上虚拟多个vNIC的10Gb 网卡,同时也是唯一支持FCoE及iSCSI硬件加速功能的10Gb网卡。
其他的10Gb网卡无法同时实现以上功能。
九.HX5(2s)与B230M2对比
A:对比情况如下表:
十.HX5(4s)与B440M2对比
A:对比情况如下表:。