带表卡尺重复性和再现性分析报告
- 格式:xls
- 大小:87.00 KB
- 文档页数:4
PLEASE SPECIFY THE FOLLOWING PARAMETERS AND COMPLETE THE FORM ACCORDINGLY PARAMETERS AREK1Number of Trials Must be either 2 or 33OKK2Number of Operators Must be either 2 or 33OKK3Number of Parts Can be any value between 2 and 10 10OK'01 PSW'01 PSW'!A6'01 PSW'!A21'01 PSW'!A54'01 PSW'!H54GAGE APPROVED, USE IT Part number Part name缸体Plant一发Characteristic Gage number Coord by张伟17.25-17.75Tolerance0.5Units mm Gage name游标卡尺Phone #Total Variation (TV)0.164754Gage ECL/revision DateOPERATOR P A R T RESULTSTRIAL #12345678910AVG A117.5817.5617.5417.5617.5417.4817.5617.5417.5417.54A117.54400 217.617.5417.5417.5617.5617.517.5417.5417.5617.54A217.54800 317.617.5617.5417.5617.5417.517.5417.5417.5417.54A317.54600 Average17.5933317.5533317.5417.5617.5466717.4933317.5466717.5417.5466717.54X A17.54600 Range0.020.020.00.00.020.020.020.00.020.0R A0.01200 B117.617.5617.5617.5617.5617.517.5417.5417.5417.56B117.55200 217.617.5817.5417.5617.5617.517.5417.5417.5417.54B217.55000 317.617.5617.5617.5417.5617.517.5417.5417.5417.54B317.54800 Average17.617.5666717.5533317.5533317.5617.517.5417.5417.5417.54667X B17.55000 Range0.00.020.020.020.00.00.00.00.00.02R B0.00800 C117.5817.5617.5617.5617.5417.517.5617.5417.5417.54C117.54800 217.5817.5817.5617.5617.5417.4817.5417.5417.5417.54C217.54600 317.617.5617.5617.5617.5417.4817.5617.5417.5417.54C317.54800 Average17.5866717.5666717.5617.5617.5417.4866717.5533317.5417.5417.54X C17.54733 Range0.020.020.00.00.00.020.020.00.00.0R C0.00800 Part Avg17.5933317.5622217.5511117.5577817.5488917.4933317.5466717.5417.5422217.54222x PART =17.54778 Part Range R PART =0.10000 R =R A+ R B + R C / No of operators =0.01200+0.00800+0.00800/3R =0.00933 X DIFF=[Max (X)ABC] - [Min (X)ABC] =17.55000-17.54600X DIFF =0.00400 UCL R=R*D4 =0.00933* 2.580UCL R =0.02408 LCL R=R*D3 =0.00933*0.000LCL R =0.00000 UCLx=X+A2*R=17.54778+0.010UCLx=17.55733 LCLx=X-A2*R=17.54778-0.010LCL x=17.53823 OPERATOR NAME NOTE: It has been statistically proven that the Tolerance Method is betterA wangshouxin to determine measurement equipment reliability. Even with negativeB许多Kurtosis data sets, the recorded measurements will be less than 1% away C张伟from the true value if GR&R is below 30%. Contact Quality Group if you GOOD UNTIL GAGE ECL/revision CHANGE need more information.FROM DATA SHEET:R =0.00933X DIFF =0.00400R PART =0.10000Measurement Unit Analysis Base on PART TO PART Variation Repeatibility - Equipment Variation (EV)EV =R * K1% EV = 100[EV/TV]EV =0.02847Trials K1% EV =17.283 3.05Reproducibility - Appraiser Variation (AV)AV= [ ( X DIFF * K2)2 - (EV2 / nr)](n parts, r trials)% AV = 100[AV/TV]AV=0.00947Oper K2% AV = 5.753 2.70Repeatibility & Reproducibility (R & R)% R&R = 100[R&R/TV]R&R= (EV2 + AV2)% R&R =18.21R&R=0.03000Part Variation (PV)PV=R PART * K3Parts K3% PV = 100[PV/TV]PV=0.1620010 1.62% PV =98.33Total Variation (TV) 1.62PLEASE SPECIFY THE FOLLOWING PARAMETERS AND COMPLETE THE FORM ACCORDINGLY PARAMETERS AREK 1Number of Trials Must be either 2 or 33OK K 2Number of OperatorsMust be either 2 or 33OK K 3Number of PartsCan be any value between 2 and 1010OK'01 PSW '01 PSW'!A6'01 PSW'!A21'01 PSW'!A54'01 PSW'!H54GAGE APPROVED, USE ITPart number Part name缸体Plant 一发Characteristic Gage number Coord by 张伟Tolerance0.5Units mm Gage name游标卡尺Phone #Total Variation (TV)0.164754Gage ECL/revisionDate17.25-17.75。