重复性及再现性分析数据记录表模板
- 格式:xls
- 大小:155.00 KB
- 文档页数:4
量具重复性与再现性数据表
日期: 2023/6/5仪器:64#分光机测试项目:Y值QP-027-1 A/0
制表人:审核:
量具重复性和再现性報告
制表人:审核:
量具重复性与再现性数据表
日期: 2023/6/5仪器:64#分光机测试项目:X值QP-027-1 A/0
制表人:审核:
量具重复性和再现性報告
制表人:审核:
量具重复性与再现性数据表
日期: 2023/6/5仪器:64#分光机测试项目:VF QP-027-1 A/0
制表人:审核:
量具重复性和再现性報告
制表人:审核:
量具重复性与再现性数据表
日期: 2023/6/5仪器:64#分光机测试项目:Flux QP-027-1 A/0
制表人:审核:
量具重复性和再现性報告
制表人:审核:。
重复性和再现性分析报告公差法Using TOLERANCE method过程变差法6.xls]01 PSW'!H54GAGE APPROVED, USE IT'[131809356.xls'[131809356.xls]01'[131809356.xls]01'[1318093零件名称压板零件号CL3202020单位名称上海闰丰电器有限公司特性6±0.15量具号LQT-101组织人牛文军公差0.3单位mm量具名称千分尺电话023-********过程变差 (TV)0.04547量具精度0.01日期2002-8-4操作员P A R T结果TRIAL #12345678910AVGA1 6.010 6.040 6.000 5.980 5.960 6.030 6.020 6.070 5.925 6.055A1 6.0092 6.010 6.040 6.000 5.990 5.960 6.030 6.020 6.060 5.925 6.055A2 6.0093 6.005 6.030 6.000 5.990 5.950 6.035 6.030 6.070 5.925 6.060A3 6.010 Average 6.008 6.037 6.000 5.987 5.957 6.032 6.023 6.067 5.925 6.057X A 6.009 Range0.0050.0100.0000.0100.0100.0050.0100.0100.0000.005R A0.007B1 6.005 6.030 6.010 5.980 5.960 6.035 6.030 6.070 5.930 6.060B1 6.0112 6.000 6.030 6.000 5.990 5.960 6.030 6.030 6.070 5.925 6.060B2 6.0103 6.000 6.035 6.000 5.980 5.960 6.030 6.030 6.060 5.925 6.055B3 6.008 Average 6.002 6.032 6.003 5.983 5.960 6.032 6.030 6.067 5.927 6.058X B 6.009 Range0.0050.0050.0100.0100.0000.0050.0000.0100.0050.005R B0.005C1 6.005 6.050 6.000 5.990 5.960 6.035 6.030 6.080 5.925 6.060C1 6.0142 6.010 6.050 6.000 5.980 5.970 6.040 6.020 6.080 5.925 6.055C2 6.0133 6.010 6.050 6.010 5.980 5.960 6.040 6.030 6.070 5.930 6.055C3 6.014 Average 6.008 6.050 6.003 5.983 5.963 6.038 6.027 6.077 5.927 6.057X C 6.013 Range0.0050.0000.0100.0100.0100.0050.0100.0100.0050.005R C0.007 PART 6.006 6.039 6.002 5.984 5.960 6.034 6.027 6.070 5.926 6.057R PART =0.144 R =R A+ R B + R C / No of operators =0.007+0.005+0.007/3R =0.006 X DIFF=[Max (X)ABC] - [Min (X)ABC] =6.013- 6.009X DIFF =0.004 UCL R=R*D4 =0.006* 2.580UCL R =0.016 LCL R=R*D3 =0.006*0.000LCL R =0.000UCL X= 6.015LCL X= 6.006 OPERATOR NAME NOTE: It has been statistically proven that the Tolerance Method is better A罗艳艳to determine measurement equipment reliability. Even with negativeB于鹏淼Kurtosis data sets, the recorded measurements will be less than 1% away C李志from the true value if GR&R is below 30%. Contact Quality Group if you GOOD UNTIL GAGE ECL/revision CHANGE need more information.FROM DATA SHEET:R =0.006X DIFF =0.004R PART =0.144Measurement Unit Analysis Base on PART TO PART VariationRepeatibility - Equipment Variation (EV)设备变差(重复性)EV =R * K1% EV = 100[EV/TV]EV =0.004Trials K1% EV =8.2330.59Reproducibility - Appraiser Variation (AV)人员变差(再现性)AV= [ ( X DIFF * K2)2 - (EV2 / nr)](n parts, r trials)% AV = 100[AV/TV]AV=0.002Oper K2% AV = 4.5530.52Repeatibility & Reproducibility (R & R)重复性和再现性% R&R = 100[R&R/TV]R&R= (EV2 + AV2)% R&R =9.40R&R=0.004Part Variation (PV)零件间PV=R PART * K3Parts K3% PV = 100[PV/TV]PV=0.045100.31% PV =99.56Total Variation (TV)总变差VARIATION ndcTV= (R&R2 + PV2)#REF!ndc≥15TV=0.045注:1. 2次试验时,极差上控制限为3.27*R均值的均值;3次试验时,极差上控制限为2.58*R均值的均值,不大于7次试验时,无极差下控制限。
温量具重复性和再现性数据表12345678910A 160.0260.0459.9560.0560.0360.0759.9660.0560.0159.94A 1260.0260.0459.9460.0560.0360.0859.9660.0560.0059.94A 2360.0160.0459.9560.0660.0360.0859.9660.0560.0159.94A 3平均60.0260.0459.9560.0560.0360.0859.9660.0560.0159.94X A 圾差0.010.000.010.010.010.010.010.000.020.01R AB 160.0360.0559.9560.0660.0260.0759.9760.0660.0059.94B 1260.0260.0559.9560.0660.0360.0859.9760.0560.0059.94B 2360.0260.0459.9460.0560.0360.0859.9860.0660.0059.95B3平均60.0260.0559.9560.0660.0360.0859.9760.0660.0059.94X B 圾差0.010.010.010.010.010.010.010.010.010.01R BC 160.0260.0459.9560.0560.0360.0859.9660.0660.0059.94C 1260.0260.0459.9560.0660.0360.0859.9760.0560.0159.94C 2360.0360.0559.9560.0660.0260.0759.9760.0560.0159.95C 3平均60.0260.0459.9560.0660.0360.0859.9760.0560.0159.94X C 圾差0.010.010.000.010.000.010.010.010.000.01R C X=R PART =R =R A +R B +R C /No ofoperators =0.01+0.01+0.01/3.00R =X DIFF =[Max (X)ABC ] -[Min (X)ABC ] =60.02-60.01X DIFF =UCL R =R *D 4 =0.01* 2.58UCL R =LCL R R *D 3 =0.01*0.00LCL R =UCL X X +A 2*R =60.01+0.01UCL X =LCL X =X -A 2*R =60.01-0.01LCL X =评价姓名备注: 1.这是一种统计A B C测量前量具是好的,未经过修理。