蒸汽管道水力计算算例
- 格式:pdf
- 大小:275.33 KB
- 文档页数:5


DN(mm)
Dw*S(mm*mm)
Dn(mm)
λ
G(t/h)ω(m/s)Δh(Pa/m)ω(m/s)Δh(Pa/m)ω(m/s)Δh(Pa/m)ω(m/s)Δh(Pa/m)
0.5070.801421.00
0.6084.902048.20
0.7099.102782.20
0.80113.003635.80
0.90127.004596.20
1.00142.005674.2074.301038.30
1.10155.006869.8081.801254.10
1.20170.008178.2089.201489.50
1.30184.009594.3096.601744.40
1.40104.002028.60
1.50111.002332.40
1.60119.002646.0084.201068.20
1.70126.002989.0089.501205.40
1.80134.003351.6094.701332.40
1.90141.003733.80100.001499.4067.20528.20
2.00149.004135.60105.001666.0070.30585.10
2.10156.004566.80111.001822.5074.30644.80
2.20164.005007.80116.002018.3077.90707.60
2.30171.005478.20121.002205.0081.40774.20
2.40178.005958.40126.002401.0084.90842.80
2.50186.006468.00132.002597.0088.50914.30
2.60193.006997.20137.002812.6092.00989.80
2.70201.007546.00142.002949.8095.501068.20
2.80208.008114.40147.003263.4099.101146.60
T=5.00t1=10.00m=1.00ψ=0.70A=12345678910本段面积(ha)∑累计面积(ha)∑t2=∑L/v(min)t2=L/v(min)1~21501.691.6902.124910433.4216512.7388002~31501.22.892.12492.114512.125405.1349819.58810003~41001.34.194.23951.322914.239381.12661117.841100汇水面积F(ha)管内雨水流行时间设计管段编号管长L(m)降雨历时t(min)暴雨强度q(L/s·ha)设计流量Q(L/s)管径D(mm)雨水计算说明综合径流系数暗管折减系数地面集水时间雨暴雨强度重现期3337.504b=10.302N=0.678粗糙n=0.0130111213141516171819
0.502654822.510.20001.503521.1765591.373010.310.785398163.140.25001.16851.51.1823928.578940.2310.950331783.460.27501.30751.51.259871197.28990.151流速验算坡降I*L(m)地方参数地方参数管道粗糙系数
管道输水能力Qmax(L/s)设计坡度I(‰)流速v(m/s)精确坡度I(‰)过水面积A(m2)湿周x(m)水力半径R(m)雨力20
111流量验算
户数同时使用系数额定流量计算流量管道直径管道内径管段长度流速
N1K2Q2QhDdL1V
单位户m3/hmmmmmm/s
1-20.21505463401.411.9374
2-30.2204763401.410.3899
3-40.22104063402.28.8425
4-50.2303363402.27.29506
5-60.2502663401.85.74763
6-70.2701963402.24.20019
7-80.3101263402.12.65275
8-90.3806634051.32638
9-100.5600634030
10-11100634030管段编号
雷诺数运动粘度摩擦阻力系数局部阻力系数单位ζ的当量长度当量长度计算长度温度绝对粗糙度
ReνλΣζl2L2LTK
m2/smmm℃mm
34601.11.4E-050.023864341.676146.704588.10458200.130115.81.4E-050.024616311.624941.624943.02494200.125630.41.4E-050.025533411.566581.566583.76658200.121145.11.4E-050.026689811.49871.49873.6987200.116659.81.4E-050.0282211.417431.417433.21743200.112174.51.4E-050.030402711.315671.315673.51567200.17689.131.4E-050.033968611.177561.177563.27756200.13844.571.4E-050.04025613.10.993643.080288.08028200.101.4E-05#DIV/0!2#DIV/0!#DIV/0!#DIV/0!200.101.4E-05#DIV/0!23.9#DIV/0!#DIV/0!#DIV/0!200.1低压管道水力计算(钢管)
蒸汽管道计算实例
介绍
蒸汽管道通常用于工业领域中,用来传输蒸汽。为保证蒸汽管道系统的正常运行,需要进行合理的管径和流量计算,以确保适当的压力和流量。本文将介绍蒸汽管道计算的基本知识,并提供一个实际的计算实例。
基本理论
蒸汽管道流量计算公式
蒸汽管道的流量计算公式如下:
Q = 3600 x D² x C x √P
其中,Q表示流量(kg/h),D表示管径(mm),C表示流量系数,P表示差压(MPa)。
蒸汽管道流量系数
流量系数C与管道阻力有关,通常可以参考表格获得具体数值。
蒸汽管道阻力
蒸汽管道阻力由以下几个因素组成:
• 管道摩阻:蒸汽在管道内流动时会与管道内壁发生摩擦,产生摩阻力。
• 管道弯头:管道中弯头对蒸汽产生阻力。
• 管道机件:如减压阀、流量计等都会对蒸汽产生阻力。
计算实例
假设我们需要计算一个长度为200m、DN100的蒸汽管道的流量和压力。已知管道的起点处蒸汽压力为1.6MPa,终点处需要维持1.2MPa的使用压力。
我们可以采用以下步骤来进行计算:
1. 计算蒸汽在管道中的速度
首先,我们需要计算蒸汽在管道中的速度,以确保蒸汽不会在管道内过度加速或减速。我们可以使用以下公式来计算蒸汽速度:
V = Q / (π x D² / 4) / 3600 其中,V表示蒸汽的速度(m/s),Q表示流量(kg/h),D表示管径(mm)。
本实例中,管道的流量为2000kg/h,管径为DN100(约为114mm),因此可得到蒸汽速度为11.4m/s。
2. 计算流量系数
接下来,我们需要计算流量系数C。由于我们的管道是直线管道,因此流量系数为1。
3. 计算差压
我们需要计算蒸汽在管道中的压力损失,并最终计算出需要的使用压力。使用以下公式可以计算蒸汽在管道中的压力损失:
ΔP = λ x L / D x (V² / 2g)
其中,ΔP表示压力损失(MPa),λ表示管道的摩阻系数,L表示管道长度(m),D表示管径(mm),V表示蒸汽速度(m/s),g表示重力加速度。