一体化电源系统操作说明 最新版本
- 格式:doc
- 大小:41.00 KB
- 文档页数:10
GeneralEaton eliminates many of the hazards associated with manual internal tap-changing of distribution transformers with its Cooper Power™ series 100 A externally operated one-, two- and three-phase under-oil tap-changer switch family. Line crews need not be exposed to high voltage conductors and hot transformer fluids. External operation also eliminates the need to dismount and open pole-type transformers for voltage adjustment, which exposes the transformer tank interior to contamination.The tap-changer switch is designed for use in distribution transformers filled with transformer oil (mineral oil), Envirotemp™ FR3™ fluid, or an approved equivalent.The switch body, rotor, and shaft are made of a high strength, glass-filled thermoplastic material. The operating shaft is sealed against leakage by two high temperature resistant Viton® O-Rings.(Image on top left, one-phase tap-changer with cap/wrench, image lower left three-phase tap-changer with padlockable flexible hookstick pointer handle and index plate.)100 A externally operated one-, two-and three-phase tap-changer switchHandle OptionsHandle options include a cap/wrench, 2.25” lever (metal orthermoplastic), and hookstick-operable. The cap/ wrench features a white arrow inside the handle for position indication, and has a one-way-in/one-way-out operating feature that ensures positive operation. The threaded cap protects the shaft seal from contamination. The lever handle has an indexing screw to ensure complete, positive switch contact. The lever handle can be ordered with an optional pad-lockable feature. The hookstick handle is available in flexible, multi-piece, or rigid, one-piece configurations, with pad-lockable option available. (See Tables 5 and 8 for a complete listing.)Stationary contactsFor ease of connection, the following optional stationary contacts are available: bolt tabs, or 14-16 AWG, 12-10 AWG, or 8 AWG crimp terminals.InstallationNo special tools are required. The switch body is installed through a keyed 1.33 inch (34 mm) hole in the tank wall and sealed by an inside gasket. An outer sealing nut is tightened to a torque of 80 to 120 in.-lb. Refer to Installation Instruction Sheet S800-57-1 fordetails.2Catalog Data CA800003ENEffective April 2015100 A externally operated tap-changer switch/cooperpowerseriesFigure 1. One-Phase Cap/Wrench Operable Switch.otee:N Dimensions given are for reference only.* Dimensions will decrease as tank wall thickness increases. Maximum dimensions given with 14 gauge tank wall.Figure 2. One-Phase Lever Handle Switch.Figure 3. One-Phase Flexible Hookstick Handle Switch.Figure 5. One-Phase Mounting Hole and Switch with and without T erminal Posts.Figure 4. One-Phase Rigid 1-Piece Hookstick Handle Switch.T able 3. Switch Dimensions in/(mm)Contact TypeA**BBolt Tabs for 1/4” Bolts Bent 90°2.91(74) 2.81(71)16-14 AWG Terminals Short Shank3.48(88.4) 2.59(66)12-10 AWG Terminals Short Shank 3.48(88.4) 2.59(66)8 AWG Terminals Short Shank 3.57(90.7) 2.59(66)Bolt Tab Straight4.47(113) 2.59(66)16-14 AWG Terminals Long Shank4.20(107) 2.59(66)12-10 AWG Terminals Long Shank 4.20(107) 2.59(66)8 AWG Terminals Long Shank 4.20(107) 2.59(66)Bolt Tab Bent 45° 1/4-20 Threaded Stud 4.39(113) 2.59(66)Bolt Tab Bent 90° 1/4-20 Stud4.07(103) 2.81(71)6 AWG Terminals Straight5.74(146)2.59(66)6 AWG Terminals 45°4.90(125)2.84(73)** “A” dimension reflects use of standard length terminals onone-phase switches.3Catalog Data CA800003ENEffective April 2015100 A externally operated tap-changer switch /cooperpowerseriesT able 4. One-Phase SwitchContact TypeCatalog NumberTap-Changer without Terminal Posts Bolt Tab - Bent 90°Accepts 1/4 inch Hardware 2237500C0116-14 AWG Terminals 2237500C0212-10 AWG Terminals 2237500C038 AWG Terminals 2237500C046 AWG Terminals Straight2237500C1346 AWG Terminals 45°2237500C13516-14 AWG Terminals Long Shank2237500C1212-10 AWG Terminals Long Shank 2237500C138 AWG Terminals Long Shank2237500C14Tap-Changer with Terminal Posts Bolt Tab - Bent 90°Accepts 1/4 inch Hardware 2237500C0616-14 AWG Terminals 2237500C0712-10 AWG Terminals 2237500C088 AWG Terminals 2237500C096 AWG Terminals Straight2237500C1366 AWG Terminals 45°2237500C13716-14 AWG Terminals Long Shank2237500C1712-10 AWG Terminals Long Shank 2237500C188 AWG Terminals Long Shank2237500C19Ordering InformationOne-phase switchTo order a one-phase 100 A tap-changer switch, specify catalog numbers for one switch and one handle kit.T able 5. One-Phase Handle KitsContact TypeCatalog NumberHandle KitsCap/Wrench Combination Handle 2237947A14H Lever Handle, 2.25 inch, Metal Position A-E2237947A39H Cap Wrench with Index Plate Position A-E 2237947A46H Pad-lockable Lever Handle, 2.25 inch, Metal Position A-E2237947A44H Flexible Hookstick Handle, 2.25 inch Position A-E2237947A127H Pad-lockable Flexible Hookstick Handle, 2.25 inch Position A-E2237947A195H2.25 inch Thermoplastic Lever Handle 100 A Tap-Changer Position A - E 2237947A161H 100 A Tap-Changer Position 1 - 52237947A162HOne-Piece Rigid Pad-lockable Hotstick Handle 100 A Tap-Changer Position A - E 2237947A301H 100 A Tap-Changer Position 1 - 52237947A302Hotee:N Special Switch and Hardware Kits available on request. Contact your Eaton representative for more information.4Catalog Data CA800003ENEffective April 2015100 A externally operated tap-changer switch/cooperpowerseriesFigure 6. T wo- and Three-Phase Cap/Wrench Operable Switch.Figure 7. T wo- and Three-Phase Flexible Hookstick Handle Switch.Figure 9. One-Piece Rigid Hookstick Handle.Figure 10. T wo- and Three-PhaseMounting Hole and Switch Diameter.Figure 8. T wo- and Three-Phase LeverHandle Switch.otee:N Dimensions given are for reference only.* Dimensions will decrease as tank wall thickness increases. Maximum dimensions given with 14 gauge tank wall.5Catalog Data CA800003ENEffective April 2015100 A externally operated tap-changer switch /cooperpowerseriesT able 6. Switch Dimensions in/(mm)Contact TypeA*B (20)B (30)Bolt Tabs 90° 2.91(74) 5.35(135.9)8.20(208.3)Bolt Tabs Straight 4.47(113.4) 5.35(135.9)8.20(208.3)16-14 AWG Terminals Short Shank4.20(106.6)5.35(135.9)8.20(208.3)12-10 AWG Terminals Short Shank 4.20(106.6) 5.35(135.9)8.20(208.3)8 AWG Terminals Short Shank 4.20(106.6) 5.35(135.9)8.20(208.3)Bolt Tab Bent 45°1/4-20 Threaded Stud 4.38(113) 5.43(139)8.36(212)Bolt Tab Bent 90°1/4-20 Threaded Stud 4.07(103) 5.56(141)8.55(217)6 AWG Terminals Straight 5.74(146) 5.35(136)8.20(208)6 AWG Terminals 45°4.90(125)5.60(142)8.45(215)* “A” dimension reflects use of long shank terminals on two-phase and three-phase switches.Ordering informationT wo- and Three-phase switchTo order a two-phase or three-phase 100 A tap-changer switch, specify catalog numbers for one switch and one handle kit.otee:N Special Switch and Hardware Kits available on request. Contact your Eaton representative for more information.T able 7. T wo- and Three-Phase SwitchesContact TypeCatalog NumberTwo-Phase Switches Bolt Tab - Bent 90°Accepts 1/4 inch Hardware 2237500C20Bolt Tab Straight 2237500C2116-14 AWG Terminals Long Shank2237500C2212-10 AWG Terminals Long Shank 2237500C238 AWG Terminals Long Shank2237500C24Bolt Tab - Bent 45° with 1/4 inch Stud2237500C266 AWG Terminals Straight 2237500C1386 AWG Terminals 45°2237500C139Three-Phase Switches Bolt Tab - Bent 90°Accepts 1/4 inch Hardware 2237500C30Bolt Tab Straight 2237500C3116-14 AWG Terminals Long Shank2237500C3212-10 AWG Terminals Long Shank 2237500C338 AWG Terminals Long Shank2237500C34Bolt Tab Bent 45°Accepts 1/4 inch Hardware 2237500C35Bolt Tab Bent 45° with 1/4 inch Stud2237500C36Bolt Tab Bent 90° with 1/4 inch Stud2237500C39Bolt Tab Bent 45° with 1/4 inch Stud (Decks 1 & 2), Bolt Tab Bent 90° with 1/4 inch Stud (Deck 3)2237500C1416 AWG Terminals Straight 2237500C1446 AWG Terminals 45°2237500C145T able 8. T wo- and Three-Phase Handle KitsContact TypeCatalog NumberHandle KitsCap/Wrench Combination Handle 2237947A14H Lever Handle, 2.25 inch, Metal Position A-E2237947A39H Cap Wrench with Index Plate Position A-E2237947A46H Pad-lockable Lever Handle, 2.25 inch, Metal Position A-E2237947A44HFlexible Hookstick Handle, 2.25 inchPosition A-E2237947A127HPad-lockable Flexible Hookstick Handle, 2.25 inch Position A-E 2237947A195H2.25 inch Thermoplastic Lever Handle100 A Tap-Changer Position A - E 2237947A161H 100 A Tap-Changer Position 1 - 52237947A162HOne-Piece Rigid Pad-lockable Hotstick Handle100 A Tap-Changer Position A - E 2237947A301H 100 A Tap-Changer Position 1 - 52237947A302H6Catalog Data CA800003ENEffective April 2015100 A externally operated tap-changer switch/cooperpowerseriesThis page intentionally left blank.7Catalog Data CA800003ENEffective April 2015100 A externally operated tap-changer switch /cooperpowerseriesEaton and Cooper Power are valuable trademarks of Eaton in the U.S. and other countries. Y ou are not permitted to use these trademarks without the prior written consent of Eaton.IEEE Std C57.12.00™-1987 standard is a trademark of the Institute of Electrical and Electronics Engineers, Inc., (IEEE). This publication is not endorsed or approved by the IEEE.Viton ® is a registered trademark of E. I. DuPont de Nemours and Company.Envirotemp™ and FR3™ are licensed trademarks of Cargill, Incorporated.100 A externally operated tap-changer switchEaton1000 Eaton Boulevard Cleveland, OH 44122United States Eaton’s Cooper Power Systems Division 2300 Badger Drive Waukesha, WI 53188United States/cooperpowerseries © 2015 EatonAll Rights Reserved Printed in USAPublication No. CA800003ENCatalog Data CA800003ENEffective April 2015For Eaton’s Cooper Power series tap-changer switch product information call 1-877-277-4636 or visit: /cooperpowerseries.。
PROFINETPN7系列一体式I/O用户手册南京实点电子科技有限公司PN7系列一体式I/O用户手册版权所有© 南京实点电子科技有限公司2023。
保留一切权利。
非经本公司书面许可,任何单位和个人不得擅自摘抄、复制本文档内容的部分或全部,并不得以任何形式传播。
商标声明和其它实点商标均为南京实点电子科技有限公司的商标。
本文档提及的其它所有商标或注册商标,由各自的所有人拥有。
注意您购买的产品、服务或特性等应受实点公司商业合同和条款的约束,本文档中描述的全部或部分产品、服务或特性可能不在您的购买或使用范围之内。
除非合同另有约定,实点公司对本文档内容不做任何明示或默示的声明或保证。
由于产品版本升级或其他原因,本文档内容会不定期进行更新。
除非另有约定,本文档仅作为使用指导,本文档中的所有陈述、信息和建议不构成任何明示或暗示的担保。
南京实点电子科技有限公司地址:江苏省南京市江宁区胜利路91号昂鹰大厦11楼邮编:211106电话:4007788929网址:目录1产品概述 (1)1.1产品简介 (1)1.2产品特性 (1)2命名规则 (2)2.1命名规则 (2)2.2型号列表 (2)3产品参数 (3)3.1通用参数 (3)3.2数字量参数 (4)4面板 (5)4.1产品结构 (5)4.2指示灯功能 (6)4.3总线接口定义 (6)4.4电源接口定义 (7)4.5I/O接口定义 (7)5安装和接线 (8)5.1外形尺寸图 (8)5.2安装环境要求 (9)5.3模块安装 (9)5.4接线指导 (10)5.4.1电源接口接线图 (10)5.4.2I/O接口接线图 (10)6电源供给规则 (12)6.1直接供电规则 (12)6.2串联供电规则 (14)7使用 (16)7.1参数及功能配置 (16)7.1.1数字量输入滤波功能 (16)7.1.2输出清空保持功能 (16)7.2组态模块应用 (17)7.2.1在TIA Portal V17软件环境下的应用 (17)7.2.2在STEP 7-MicroWIN SMART软件环境下的应用 (31)8FAQ (40)8.1更新可访问的设备时,查找不到设备 (40)8.2下载组态时装载按钮为灰色 (40)1产品概述1.1产品简介PN7系列一体式I/O模块,采用PROFINET工业以太网总线接口,是标准IO架构的PROFINET从站设备,可以与多个厂商的PROFINET网络兼容,为用户高速数据采集、优化系统配置、简化现场配线、提高系统可靠性等提供多种选择。
一体式直流充电桩使用说明书(V.01)深圳市科陆电子股份科技有限公司目录前言 (3)安全注意事项 (3)第1章概述 (4)1.1产品简介 (4)1.2产品原理框图 (5)1.3 主要参数说明 (5)1.4产品性能与特点 (6)1.5产品使用环境 (7)1.6产品命名 (7)1.7产品设计规范 (7)第2章主要功能模块介绍 (7)2.1充电模块 (7)2.2 充电桩的整体功能介绍 (9)第3章操作说明 (11)3.1.2单枪操作过程 (11)3.2.2 双枪操作过程 (13)3.3操作注意事项 (16)3.4充电状态说明 (17)3.5指示灯说明 (17)3.6急停开关使用说明 (18)第4章安装 (18)4.1安装条件 (18)4.2桩体安装 (18)4.3电缆接入 (19)第5章参数配置 (19)5.1使用前安全检查 (19)5.2参数配置 (19)第6章包装、运输和存储 (21)第7章订货须知及售后服务 (21)7.1订货须知 (21)7.2 售后服务 (21)7.3 附件清单 (21)附录 (22)附录一故障信息表 (22)附录二技术标准及规定 (23)附录三电气原理图 (24)附录四水泥基建图 (25)操作之前,请详细阅读使用说明书,以了解设备正确的使用方法。
阅毕请妥善保存,以便日后查考。
前言感谢各位对深圳市科陆电子科技股份有限公司产品的支持,深圳市科陆电子科技股份有限公司(股票代码:002121)是国家级高新技术企业,致力于智能电网和新能源应用、节能减排提供整体技术与产品解决方案。
企业成立于1996年,2007年3月在深圳证交所挂牌上市。
现注册资本39969.3万元,员工接近3000人,拥有超过700人的技术研发团队,在深圳建有近3.6万平方米的研发基地和近10万平米生产基地,并在成都、南昌、昆山等城市建有智能电网大型工业园。
科陆电子借助新能源开发、低碳经济建设的良好发展机遇,依托产学研创新机制,建立了国家能源局可再生能源规模化储能并网工程实验室、广东省智能电网院士工作站、博士后科研工作站、科技特派员企业工作站、深圳市企业技术中心、科陆技术研究院,形成强大的技术创新平台。
一体化电源系统操作说明最新版本交流柜智能控制器运行维护、操作说明及注意事项交流柜巡视内容(正常运行时)按键操作说明查看信息注意事项本站N0.63 1#交流进线屏、NO.64 2#交流进线屏A TS控制器均采用厦控XKQE型智能控制器。
正常运行时:(自动方式下)方式一:两个所变均有电,1号站用变带低压交流屏一段母线,2号站用变带低压交流屏二段母线:此时站用变低压侧0381、0382、0383、0384断路器均在合位。
此时两个低压交流进线屏的XKQE智能控制器面板上的电源指示灯N、R应均发绿光且无闪烁,面板上闭合指示灯N应发绿光且无闪烁。
方式二:1号站用变带低压交流屏一、二段母线:站用变低压侧0381、0383断路器应均在合位,0382、0384断路器均在分位。
此时N0.63 1#交流进线屏的XKQE智能控制器面板上的电源指示灯N应发绿光且无闪烁,面板上闭合指示灯N应发绿光且无闪烁;NO.64 2#交流进线屏XKQE 智能控制器面板上的电源指示灯R应发绿光且无闪烁,面板上闭合指示灯R应发绿光且无闪烁。
方式三:2号站用变带低压交流屏一、二段母线:站用变低压侧0382、0384断路器应均在合位,0381、0383断路器均在分位。
此时N0.63 1#交流进线屏的XKQE智能控制器面板上的电源指示灯R应发绿光且无闪烁,面板上闭合指示灯R应发绿光且无闪烁;NO.64 2#交流进线屏XKQE 智能控制器面板上的电源指示灯N应发绿光且无闪烁,面板上闭合指示灯N应发绿光且无闪烁。
“电源指示灯”哪个发绿光且无闪烁,就说明哪个电源正常;“闭合指示灯”哪个发绿光且无闪烁,就说明哪个电源投入工作。
交流馈线屏上已合断路器的指示灯应发红光且无闪烁。
按键功能说明:1、“N电源投入按钮”用于电动投入常用电源(电动方式下)。
2、“R电源投入按钮”用于电动投入备用电源(电动方式下)。
3、“主菜单按钮”用于进入菜单。
4、“选择按钮”用于子菜单光标切换。
一体化操作说明书——变频器显示屏共4行显示,4个操作键。
变频器的主界面如下:在主界面时,按4键可进入菜单。
菜单说明:主菜单:A0 速度B0 速度曲线C0 起动/停止D0 驱动参数E0 继电器输出F0 操作参数G0 控制参数H0 故障记录在主菜单时,按4键进入子菜单。
A1 返平层速度Vn:保留,未用。
A2 检修速度 Vi:设置检修运行时的速度。
A3 爬行速度V0:设置电梯减速靠近门区时的爬行速度。
此值可用于调节电梯平层。
电梯欠平层时,加大此值,电梯过平层时,减小此值。
一般使用“C2 制动减速度”菜单调节电梯平层。
A4 低速V1:电梯以单段速运行时,用V1设置的速度。
A5 中速V2:电梯以两段速运行时,单层运行用低速V1,多层运行用中速V2。
A6 高速V3:电梯以三段速运行时,单层运行用低速V1,多层运行由微机选择用中速V2或高速V3。
B1 加速度:电梯起动时直线段的加速度。
B2 加速度变化率:电梯起动时曲线段的加速度。
B3减速度:电梯停止时直线段的减速度。
B4 减速度变化率:电梯停止时曲线段的减速度。
减速度和减速度变化率用来调节爬行时间,这两个值越小,爬行时间越短。
这两个值也不能太小,否则会失去爬行段,导致电梯不平层。
B5 制动距离V1:设为“学习”时,如果电梯以V1速度正常运行一次,变频器将自动记忆V1速度的减速距离,并自动将“学习”,改为“开”,在下一次以V1运行减速时,变频器自动计算减速度和减速度变化率,使爬行距离最短。
设为“关”时,不使用此功能。
B6 制动距离V2:设为“学习”时,如果电梯以V2速度正常运行一次,变频器将自动记忆V2速度的减速距离,并自动将“学习”,改为“开”,在下一次以V2运行减速时,变频器自动计算减速度和减速度变化率,使爬行距离最短。
设为“关”时,不使用此功能。
B7 制动距离V3:设为“学习”时,如果电梯以V3速度正常运行一次,变频器将自动记忆V3速度的减速距离,并自动将“学习”,改为“开”,在下一次以V3运行减速时,变频器自动计算减速度和减速度变化率,使爬行距离最短。
机电一体化实训操作系统说明书一系统概述本套机电一体化实训系统是以台湾eVIEW触摸屏为监控设备,西门子S7-300型可编程序控制器作为主控制器,S7-200型可编程控制器作为单元控制器,所有的设备之间采用西门子专用网络连接的形式。
配有由8个单元组成的执行器及机械装置,每站的执行器采用托板形式,由托板固定在实验平台上,每站的控制器采用挂板形式,挂在实验台的网孔板上,电、气连接由学生自己动手,完成插接过程,提高动手能力系统涵盖了自动化领域中的常用技术;可编程控制器技术、触摸屏监控技术、气动技术、机械传动技术、传感器技术、配线技术、机械装配技术、机电联调技术、PLC编程技术、各种常用电机的控制技术等本套系统由8个单元组成;它们是储料单元、翻转送料单元、尺寸检测单元、材质检测单元、机械手送料单元、加工单元、搬运单元、立体仓储单元。
每个单元有各自动作特点和要求,可成组编程,也可以单元分步编程,其工作任务是将随设备一起提供的工件由原料仓库取出,经过高度检测,材质检测,然后对非金属工件进行加工,最后按材料的不同将工件进行分捡入库。
同时在几个工作单元之间配以不同形式的工件传送装置最终完成一整套工作及工艺过程。
二控制器介绍1.触摸屏:触摸屏是一种典型的人机界面,它在操作人员和机器设备之间作双向沟通的桥梁,用户可以自由的组合文字、按钮、图形、数字等来处理或监控管理及应付随时可能变化信息的多功能显示屏幕。
使用触摸屏能够明确指示并告知操作员机器设备目前的状况,使操作变得简单生动,并且可以减少操作上的失误。
使用人机界面还可以使机器的配线标准化、简单化,同时也能减少PLC控制器所需的I/O 点数。
MT500 系列触摸屏是专门面向PLC 应用的,它不同于一些简单的仪表式或其它的一些简单的控制PLC的设备,其功能非常强大,使用非常方便,非常适合现代工业越来越庞大的工作量及功能的需求。
日益成为现代工业必不可少的设备之一。
2.西门子S7-300可编程控制器:SIMATIC S7-300 是一种通用型PLC,能适合自动化工程中的各种应用场合,尤其是在生产制造过程中的应用。
交直流电源一体化系统调试一、系统预检1、设备检查确保所有系统设备已正确安装到指定位置,并根据设备手册检查安装是否符合规范。
2、连接检查检查设备之间的连接,确保连接牢固、接地正确、线缆无损坏,无短路、断路或其他连接问题。
3、电源连接确保交流电源和直流电源的供电连接正确,电源电压符合设备要求,并进行电源输入开关检查。
4、仪表校验使用校准合格的测试仪表对系统各模块的输入输出进行校验,确保仪表的准确度和稳定性。
5、设备状态检查启动系统设备,确保所有设备处于正常状态,无异常报警或指示灯提示故障。
6、系统参数检查核对系统参数设置,包括电压、电流、频率等参数,确保设置正确,符合系统设计要求。
7、冷却系统检查检查冷却系统,确保冷却液循环畅通,冷却设备正常工作,防止过热造成设备损坏。
8、防护装置检查核对系统的保护装置设置和功能,确保各保护装置的动作参数和响应时间符合要求。
9、通信接口检查检查系统的通信接口,确保各设备之间的通信正常,能够准确传输数据和控制信号。
10、安全检查确认安全开关和急停按钮的功能正常,以及其他安全措施是否有效,以保障操作人员的安全。
11、记录和文档检查确认相关系统文档和记录的完整性,包括设备清单、图纸、维护手册等。
二、交流电源调试1、电压和频率设置根据系统要求,设置交流电源的输出电压和频率,确保与系统需要的参数一致。
2、启动交流电源启动交流电源模块,并监测输出电压和频率是否达到设定值。
3、电压稳定性测试检查输出电压的稳定性,确保在负载变化时电压波动不超出允许范围。
4、过载保护测试通过逐步增加负载,测试交流电源的过载保护功能,确保在超负载情况下自动切断输出并保护设备。
5、瞬时电压波动测试通过人工或自动方式模拟电网瞬时电压波动,检验交流电源的瞬时电压稳定性和恢复能力。
6、电网切换测试模拟电网切换,测试交流电源的切换时间和切换稳定性,确保在切换时不会对系统产生过大的冲击。
7、并联运行测试若系统中存在多个交流电源模块,测试它们的并联运行能力,确保能够协调工作,负载共享均衡。
GQH-T交直流一体化电源系统产品简介:GQH-T交直流一体化电源系统是泰昂能源推出的将交流电源(AC)、直流操作电源(DC)、电力专用交流不间断电源(UPS)和电力专用逆变电源(INV)、通信用直流变换电源(DC-DC)等变电站站用电源一体化设计、一体化配置、一体化监控的电源系统。
系统概述:GQH-T交直流一体化电源系统是泰昂能源推出的将交流电源(AC)、直流操作电源(DC)、电力专用交流不间断电源(UPS)和电力专用逆变电源(INV)、通信用直流变换电源(DC-DC)等变电站站用电源一体化设计、一体化配置、一体化监控的电源系统。
该系统对站用电源进行全面整合:将站用交流电源系统、直流电源系统、逆变电源系统、通信电源系统统一设计、监控、生产、调试、服务;通过一体化监控模块将站用电源各子系统通信网络化,实现站用电源信息共享,建立数字化电源软件平台;通过将站用电源所有开关智能模块化,集中功能分散化,实现模块外无二次接线,无跨屏二次电缆,建立数字化电源硬件平台;一体化监控模块通过以太网接口、IEC61850规约与上位机系统通信,使站用电源系统成为开放式系统。
适用范围:A、数字化变电站/绿色变电站/智能化变电站/程序化变电站;B、6kV~1000 kV各种电压等级常规变电站。
应用价值1、实现电源网络化、智能化,一体化程度更高实现在一个平台上对整个电站电源的交与直流系统、逆变电源系统、通信进行监控,解决由不同供应商提供的各独立电源通信规约兼容等问题,提高系统网络化、智能化程度。
A、各子系统智能设备通过通信网络接入一体化监控器,一体化监控器1个通信口、一种规约接入综自/调度系统;B、可以在一个位置实时查看各子系统的电量、开关状态、事件信息等,可修改系统参数、运行方式、遥控开关,实现站用电源“四遥”功能;C、统一的信息共享平台,可以提高电源综合自动化应用水平,进行电源协调联动、状态检修等深层次开发应用。
2、电源更加安全可靠一次、二次设备均采用成熟可靠技术,其本身没有任何技术风险,通过一体设计可以有效避免电源的安全隐患。