999SD00010液体渗透探伤检验规范-译文
- 格式:docx
- 大小:44.75 KB
- 文档页数:5
受控状态: 文件编号:ZZM-QP-0824.2 Controlled Status Document No.:发放编号:Issuing NO.:液体渗透探伤规程Liquid penetrant Examination Procedure(Rev.03)编 制: 质检部 日期: May-26-2011 Compiled by QC Department Date审 核: 日期Verified by:Date批 准: 日期Approved by:Date发行日期:May-28-2011实施日期:May-28-2011 Issue date Execution Date1.目的:依ASTM E165标准要求,结合API 6A标准、核电用《钴基SFA-5.13 ECoCr-A手工焊用焊条采购规程》(SM2-ME02-GPP-059)等等,为液体渗透检测——可视法建立检测方法、规定检测人员要求、明确产品接受准则。
Establishes the methods, personnel requirements and acceptance criteria for performing liquid penetrant examinationusing the visible methods in accordance with the requirements of API Specification 6A, Procurement specificationfor SFA-5.13 EcoCr-A Covered Electrode for SMAW (SM2-ME02-GPP-059)etc. This procedure complies with therequirements of ASTM E165.2.适用范围:本方法适用于本公司精铸件、锻件、机加工件产品的焊接/补焊及焊接(接焊、焊补、堆焊和表面硬化)件用液体渗透检测方法,检查表面组织中断:如疏松、气孔、龟裂、叠痕、冷隔、渗漏、夹渣和熔合不足(虚焊)等缺陷。
CONTENTS 目录1.0 Scope 范围2.0 Reference Specification 参考规范3.0 Personnel 人员4.0 Examination Method 检验方法5.0 Examination Materials 检验材料6.0 Surface Preparation 表面准备7.0 Surface Cleaning 表面清洗8.0 Exert Penetrate in tested surfaces 在检测面施加渗透剂9.0 Removal of excess penetrate 清除多余的渗透剂10.0 Drying Treatment 干燥处理11.0 Exerted Developer 施加显象剂12.0 Interpretation 观察评定13.0 Retesting 复验14.0 Acceptance Standard 合格标准15.0 Rear Treatment 后处理16.0 Inspection Report 检测报告17.0 Related Forms 附表18.0 Revision Note 修改声明1.0 Scope 范围This procedure is applicable to liquid penetrant examination for open defects of weld surfaces.本程序使用于着色(液渗)检测以显示焊缝表面缺陷2.0 Reference Specification 参考规范ASME/ANS/B31.3 Chemical Plant and Oil Refining pipe, 1993 Edition;ASME/ANSI B31.3 化工厂和炼油管道,1993。
AP1650 Welded Steel Tanks for Oil Tank 9th1993(Addenda1994,1995);API 650 焊制钢储油罐ASME Code V, Nondestructive Examination;Liquid Penetrant Examination Volume of America Nondestructive Examination Handbook,written by America Nondestructive Examination Institute, 1994 Edition.ASME V 美国无损检测手册液渗检查卷美国无损检测学会编3.0 Personnel 人员The personnel involved in this project shall be certified with nondestructive testing (LTP) level 2 or 3 to ANSI TC-1A or equivalent.所有参加本工程的NDT人员应持有ANSI TC-1A或类似标准的渗透专业II级或III级资格证书。
ISO12095液体渗透检测规程目录Content1、范围 (2)2、引用文件 (2)3、检测人员 (2)4、设备及器材 (2)5、渗透检测方法选用 (3)6、检测条件 (3)7、检测程序 (4)8、验收 (5)9、报告 (7)ISO12095液体渗透检测规程1、范围1.1本规程依据ISO 12095标准要求编写,本程序适用于根据4种测试范围(见表3和表4)对焊接钢管表面缺陷进行渗透检验。
1.2可参照相关产品质量标准对整管表面或部分表面进行检验。
2、引用文件ISO12095 《压力用途的承压无缝和焊接钢管液体渗透试验》ISO11484 《承压用钢管—无损检测人员资格鉴定与认证》ISO3452 《无损检测--渗透检测--一般原则》ISO3453 《无损检测—液体渗透性检测—验证手段》3、检测人员3.1 检测应由制造商指定的,按照ISO11484评定合格的人员执行。
第三方检测时,应由购方和制造厂协议。
4、设备及器材4.1渗透材料4.1.1 渗透材料包括检验过程中使用的所有渗透剂、溶剂或清洗剂、显像剂等。
4.1.2所使用的液体渗透材料,应没有卤素(氯/氟)和硫(对于奥氏体不锈钢管,氟含量会产生危害,对于高温用镍基合金管,硫含量会产生危害。
具体的渗透材料牌号见下表1。
表1 渗透材料牌号4.2擦洗材料要求清洁,吸水,不起毛;具有良好的擦洗作用。
4.3试块4.3.1Ⅰ型参考试块主要用于确定荧光和着色渗透产品族的灵敏度等级。
4.3.2Ⅱ型参考试块主要用于评定荧光和着色渗透产品族的综合性能。
a.评定某渗透检测剂系统和某渗透检测程序对于不同尺寸缺陷的分辨能力。
b.评定某渗透检测剂系统和某渗透检测程序对某粗糙度表面的清洗能力。
4.3.3试块的清洗和保存试块使用后要用丙酮进行彻底的清洗。
清洗后,在将试块放入装有丙酮和无水酒精的混合液体(体积混合比1:1)的密闭容器中保存,或用其它有效方法保存。
4.4照度计照度计应至少每年校验一次,或每当仪器修理以后应校验。
作业文件JXZJ-ZY-17
渗透检测操作规程
1、目的
为了规范渗透检测操作程序,确保操作人员正确合理使用,维护设备安全,制定本规程。
2、适用范围
本规程适用于金属材料制成的工件及其零部件表面开口缺陷的检测。
3、检测步骤
3.1 对工件需要检测的部位进行予清洗.
3.2 根据被检样品大小、形状、数量和检测部位施加渗透剂
3.3 在15-50℃的温度条件下,渗透剂的渗透时间一般不得少于10min。
3.4清洗多余的渗透剂:溶剂去除型渗透剂用清洗剂清洗。
除特别难于清洗的地方外,一般应先用干净不脱毛的布依次擦拭,直至大部分多余的渗透剂被清洗后,再用蘸有清洗剂的干净不脱毛的布或纸进行擦拭,直至将被检面上多余的渗透剂全部擦净。
但必须注意,不得往复擦拭,不得用清洗剂直接在被检面冲洗。
3.5进行干燥处理,处理时间为5-10min。
3.6施加显像剂
3.6.1显像剂在使用前应充分搅拌均匀,显像剂施加应薄而均匀,不可在同一地点反复多次施加。
3.6.2喷施显像剂时,喷嘴离被检面距离为300-400mm,喷洒方向与被检面夹角为30o-40o。
3.7 观察显示迹痕在显像剂施加后7-30min内进行。
3.8 根据图纸、工艺、技术要求按JB4730-2005标准对缺陷进行观察、分析、评定、记录。
3.9检测结束后,应及时清除显像剂。
3.10按有关要求出具检测报告。
无损检测中英文对照无损检测常用词汇中英文对照表English 中文释义A.C magnetic saturation 交流磁饱和Absorbed dose 吸收剂量Absorbed dose rate 吸收剂量率Acceptance criteria验收准则Acceptanc limits 验收范围Acceptable quality level可验收质量等级Acceptance level 验收水平(验收等级)Acceptance standard 验收标准Accumulation test 累积检测Acoustic emission count(emission count)声发射计数(发射计数)Acoustic emission transducer 声发射换能器(声发射传感器)Acoustic emission(AE) 声发射Acoustic holography 声全息术Acoustic impedance 声阻抗Acoustic impedance matching 声阻抗匹配Acoustic impedance method 声阻法Acoustic wave 声波Acoustical lens 声透镜Acoustic—ultrasonic 声-超声(AU)Activation 活化Activity 活度Adequate shielding 安全屏蔽Ampere turns 安匝数Amplitude 幅度Angle beam method 斜射法Angle of incidence 入射角Angle of reflection 反射角Angle of spread 指向角Angle of squint 偏向角Angle probe 斜探头Angstrom unit 埃(A)Area amplitude response curve 面积幅度曲线 Area of interest 评定区Artificial discontinuity 人工不连续性Artifact 假缺陷Artificial defect 人工缺陷Artificial discontinuity 标准人工缺陷A-scan A 型扫描A-scope; A-scan A 型显示Attenuation coefficient 衰减系数Attenuator 衰减器Audible leak indicator 音响泄漏指示器Automatic testing 自动检测 Autoradiography 自射线照片Avaluation 评定Background背景Barium concrete 钡混凝土Barn 靶Base fog 片基灰雾Bath 槽液(浸湿)Bayard- Alpert ionization gage B- A 型电离计Beam 声束Beam ratio 光束比Beam angle 束张角Beam axis 声束轴线Beam index 声束入射点Beam path location 声程定位Beam path; path length 声程Beam spread 声束扩散Betatron 电子感应加速器Bimetallic strip gage 双金属片计Bipolar field 双极磁场Black light filter 黑光滤波器Black light; ultraviolet radiation 黑光Blackbody 黑体Blackbody equivalent temperature 黑体等效温度Bleakney mass spectrometer 波利克尼质谱仪 Bleedout 渗出Bottom echo 底面回波Bottom surface 底面Boundary echo(first) 边界一次回波Bremsstrahlung 轫致辐射Broad-beam condition 宽射束Brush application 刷涂B-scan presenfation B 型扫描显示B-scope; B-scan B 型显示C- scan C 型扫描Calibration, instrument 设备校准Capillary action 毛细管作用Carrier fluid 载液Carry over of penetrate 渗透剂移转Cassette 暗合Cathode 阴极Central conductor method 中心导体法Characteristic curve 特性曲线Characteristic curve of film 胶片特性曲线Characteristic radiation 特征辐射Chemical fog 化学灰雾Cine-radiography 射线(活动)电影摄影术Cintact pads 接触垫Circumferential coils 圆环线圈Circumferential field 周向磁场Circumferential magnetization method 周向磁化法Clean 清理Clean- up 清除Clearing time 定透时间Coercive force 矫顽力Coherence 相干性Coherence length 相干长度(谐波列长度) Coi1,test 测试线圈Coil size 线圈大小Coil spacing 线圈间距Coil technique 线圈技术Coil method 线圈法Coilreference 线圈参考Coincidence discrimination 符合鉴别Cold-cathode ionization gage 冷阴极电离计 Collimator 准直器Collimation 准直Collimator 准直器Colour contrast penetrant着色渗透剂Combined colour comtrast and fluorescent pe netrant 着色荧光渗透剂Compressed air drying 压缩空气干燥Compressional wave 压缩波Compton scatter 康普顿散射Continuous emission 连续发射Continuous linear array 连续线阵Continuous method 连续法Continuous spectrum 连续谱Continuous wave 连续波Contract stretch 对比度宽限Contrast 对比度Contrast agent 对比剂Contrast aid 反差剂Contrast sensitivity 对比灵敏度Control echo 监视回波Control echo 参考回波Couplant 耦合剂Coupling 耦合Coupling losses 耦合损失Cracking 裂解Creeping wave 爬波Critical angle 临界角Cross section 横截面Cross talk 串音 Cross-drilled hole 横孔Crystal 晶片C-scope; C-scan C 型显示Curie point 居里点Curie temperature 居里温度Curie(Ci) 居里Current flow method 通电法Current induction method 电流感应法Current magnetization method 电流磁化法Cut-off level 截止电平Dead zone 盲区Decay curve 衰变曲线Decibel(dB) 分贝Defect 缺陷Defect resolution 缺陷分辨力Defect detection sensitivity 缺陷检出灵敏度Detection sensitivity检测灵敏度Detection threshold检测门槛Defect resolution 缺陷分辨力Definition 清晰度Definition, image definition 清晰度,图像清晰度Demagnetization 退磁Demagnetization factor 退磁因子Demagnetizer 退磁装置Densitometer 黑度计Density 黑度(底片)Density comparison strip 黑度比较片Detecting medium 检验介质Detergent remover 洗净液Developer 显像剂Developer, agueons 水性显象剂Developer, dry 干显象剂Developer, liquid film 液膜显象剂Developer, nonaqueous (sus- pendible)非水(可悬浮)显象剂Developing time 显像时间Development 显影Diffraction mottle 衍射斑Diffuse indications 松散指示Diffusion 扩散Digital image acquisition system 数字图像识别系统Dilatational wave 膨胀波Dip and drain station 浸渍和流滴工位Dip rinse浸洗Direct contact magnetization 直接接触磁化Direct exposure imaging 直接曝光成像Direct contact method 直接接触法Directivity 指向性Discontinuity 不连续性Distance- gain- size-German A VG 距离- 增益- 尺寸(DGS 德文为A VG)Distance marker; time marker 距离刻度Dose equivalent 剂量当量Dose rate meter 剂量率计Dosemeter 剂量计Double crystal probe 双晶片探头Double probe technique 双探头法Double transceiver technique 双发双收法Double traverse technique 二次波法Dragout 带出Drain time 滴落时间Drain time 流滴时间Drift 漂移Dry method 干法Dry powder 干粉Dry technique 干粉技术Dry developer 干显显像剂Dry developing cabinet 干显像柜Dry method 干粉法Drying oven 干燥箱Drying station 干燥工位Drying time 干燥时间D-scope; D-scan D 型显示Dual-focus tube 双焦点管Dual purpose penetrant 两用渗透剂Dual search unit 双探头Duplex-wire image quality indicator 双线像质指示器Duration 持续时间Dwell time 停留时间Dye penetrant 着色渗透剂Dynamic leak test 动态泄漏检测Dynamic leakage measurement 动态泄漏测量Dynamic range 动态范围Dynamic radiography 动态射线透照术Echo 回波Echo frequency 回波频率Echo height 回波高度Echo indication 回波指示Echo transmittance of sound pressure 往复透过率Echo width 回波宽度Eddy current 涡流 Eddy current flaw detector 涡流探伤仪Eddy current testiog 涡流检测Edge 端面Edge effect 边缘效应Edge echo 棱边回波Edge effect 边缘效应Effective depth penetration (EDP)有效穿透深度Effective focus size 有效焦点尺寸Effective magnetic permeability 有效磁导率Effective permeability 有效磁导率Effective reflection surface of flaw 缺陷有效反射面Effective resistance 有效电阻Elastic medium 弹性介质Electric displacement 电位移Electrostatic spraying 静电喷射Electrical center 电中心Electrode 电极Electromagnet 电磁铁Electro-magnetic acoustic transducer 电磁声换能器Electromagnetic induction 电磁感应Electromagnetic radiation 电磁辐射Electromagnetic testing 电磁检测Electro-mechanical coupling factor 机电耦合系数Electron radiography 电子辐射照相术Electron volt 电子伏恃Electronic noise 电子噪声Electrostatic spraying 静电喷涂Emulsification 乳化Emulsification of penetrant 渗透剂的乳化 Emulsification time 乳化时间Emulsifier 乳化剂Encircling coils 环绕式线圈End effect 端部效应Energizing cycle 激励周期Equalizing filter 均衡滤波器Equivalent 当量Equivalent I.Q. I. Sensitivity 象质指示器当量灵敏度Equivalent nitrogen pressure 等效氮压Equivalent penetrameter sensifivty 透度计当量灵敏度Equivalent method 当量法Erasabl optical medium 可探光学介质Etching 浸蚀Evaluation 评定Evaluation threshold 评价阈值Event count 事件计数Event count rate 事件计数率Examination area 检测范围Examination region 检验区域Excess penetrant removal多余渗透剂的去除Exhaust pressure/discharge pressure 排气压力Exhaust tubulation 排气管道Expanded time-base sweep 时基线展宽Exposure 曝光Exposure table 曝光表格Exposure chart 曝光曲线Exposure fog 曝光灰雾Exposure,radiographic exposure 曝光,射线照相曝光Extended source 扩展源Facility scattered neutrons 条件散射中子False indication 假指示(伪显示)Family 族Far field 远场Feed-through coil 穿过式线圈Field, resultant magnetic 复合磁场Fill factor 填充系数Film speed 胶片速度Film badge 胶片襟章剂量计Film base 片基Film contrast 胶片对比度Film gamma 胶片γ值Film processing 胶片冲洗加工Film speed 胶片感光度Film unsharpness 胶片不清晰度Film viewing screen 观察屏Filter 滤波器/滤光板Final test 复探Flat-bottomed hole 平底孔Flat-bottomed hole equivalent 平底孔当量Flaw 伤Flaw characterization 伤特性Flaw echo 缺陷回波Flexural wave 弯曲波Floating threshold 浮动阀值Fluorescence 荧光Fluorescent examination method 荧光检验法Fluorescent intensity 荧光强度Fluorescent penetrant 荧光渗透剂Fluorescent magnetic particle inspection 荧光磁粉检验Fluorescent dry deposit penetrant 干沉积荧光渗透剂Fluorescent light 荧光Fluorescent magnetic powder 荧光磁粉Fluorescent penetrant 荧光渗透剂Fluorescent screen 荧光屏Fluoroscopy 荧光检查法Flux leakage field 磁通泄漏场Flux lines 磁通线Focal spot 焦点Focal distance 焦距Focus length 焦点长度Focus size 焦点尺寸Focus width 焦点宽度Focus(electron) 电子焦点Focused beam 聚焦声束Focusing probe 聚焦探头Focus-to-film distance(f.f.d) 焦点-胶片距离(焦距)Fog 底片灰雾Fog density 灰雾密度Footcandle 英尺烛光Freguency 频率Frequency constant 频率常数Fringe 干涉带Front distance 前沿距离Front distance of flaw 缺陷前沿距离Full- wave direct current(FWDC)全波直流Fundamental frequency 基频Furring 毛状迹痕Gage pressure 表压Gain 增益Gamma radiography γ射线透照术Gamma ray source γ射线源Gamma ray source container γ射线源容器Gamma rays γ射线Gamma-ray radiographic equipment γ射线透照装置Gap scanning 间隙扫查Gas 气体Gate 闸门Gating technique 选通技术Gauss 高斯Geiger-Muller counter 盖革.弥勒计数器Geometric unsharpness 几何不清晰度Gray(Gy) 戈瑞Grazing incidence 掠入射Grazing angle 掠射角Group velocity 群速度Half life 半衰期Half- wave current (HW)半波电流Half-value layer(HVL) 半值层Half-value method 半波高度法Halogen 卤素Halogen leak detector 卤素检漏仪Hard X-rays 硬X 射线Hard-faced probe 硬膜探头Harmonic analysis 谐波分析Harmonic distortion 谐波畸变Harmonics 谐频Head wave 头波Helium bombing 氦轰击法Helium drift 氦漂移Helium leak detector 氦检漏仪Hermetically tight seal 气密密封High vacuum 高真空High energy X-rays 高能X 射线Holography (optical) 光全息照相Holography, acoustic 声全息Hydrophilic emulsifier 亲水性乳化剂Hydrophilic remover 亲水性洗净剂Lipophilic emulsifier 亲油性乳化剂Hydrostatic text 流体静力检测Hysteresis 磁滞Hysteresis 磁滞IACS IACSID coil ID 线圈Image definition 图像清晰度Image contrast 图像对比度Image enhancement 图像增强Image magnification 图像放大Image quality 图像质量Image quality indicator sensitivity 像质指示器灵敏度Image quality indicator(IQI)/image quality ind ication 像质指示器Imaging line scanner 图像线扫描器Immersion probe 液浸探头Immersion rinse 浸没清洗Immersion testing 液浸法Immersion time 浸没时间Impedance 阻抗Impedance plane diagram 阻抗平面图Imperfection 不完整性(缺欠)Impulse eddy current testing 脉冲涡流检测Incremental permeability 增量磁导率Indicated defect area 缺陷指示面积Indicated defect length 缺陷指示长度Indication 指示(显示)Indirect exposure 间接曝光Indirect magnetization 间接磁化Indirect magnetization method 间接磁化法 Indirect scan 间接扫查Induced field 感应磁场Induced current method 感应电流法Infrared imaging system 红外成象系统Infrared sensing device 红外扫描器Inherent fluorescence 固有荧光Inherent filtration 固有滤波Initial permeability 起始磁导率Initial pulse 始脉冲Initial pulse width 始波宽度Inserted coil 插入式线圈Inside coil 内部线圈Inside- out testing 外泄检测Inspection 检查Inspection medium 检查介质Inspection frequency/ test frequency 检测频率Intensifying factor 增感系数Intensifying screen 增感屏Interal,arrival time (Δtij)/arrival time interval (Δtij)到达时间差(Δtij)Interface boundary 界面Interface echo 界面回波Interface trigger 界面触发Interference 干涉Interpretation 解释Ion pump 离子泵Ion source 离子源Ionization chamber 电离室Ionization potential 电离电位Ionization vacuum gage 电离真空计Ionography 电离射线透照术Irradiance, E 辐射通量密度, EIsolation 隔离检测Isotope 同位素Kaiser effect 凯塞(Kaiser)效应Kilo volt kv 千伏特Kiloelectron volt keV 千电子伏特Krypton 85 氪85L/D ratio L/D 比Lamb wave 兰姆波Latent image 潜象Lateral scan 左右扫查Lateral scan with oblique angle 斜平行扫查Latitude (of an emulsion) 胶片宽容度Lead screen 铅屏Leak 泄漏孔Leak artifact 泄漏器Leak detector 检漏仪Leak testtion 泄漏检测Leakage field 泄漏磁场Leakage rate 泄漏率Leechs 磁吸盘Lift-off effect 提离效应Light intensity 光强度Limiting resolution 极限分辨率Line scanner 线扫描器Line focus 线焦点Line pair pattern 线对检测图Line pairs per millimetre 每毫米线对数Linear (electron) accelerator(LINAC) 电子直线加速器Linear attenuation coefficient 线衰减系数Linear scan 线扫查Linearity (time or distance)线性(时间或距离)Linearity, anplitude 幅度线性Lines of force 磁力线Lipophilic emulsifier 亲油性乳化剂Lipophilic remover 亲油性洗净剂Liquid penetrant examination 液体渗透检验Liquid filmdeveloper 液膜显像剂Local magnetization 局部磁化Local magnetization method 局部磁化法Local scan 局部扫查Localizing cone 定域喇叭筒Location 定位Location accuracy 定位精度Location computed 定位,计算Location marker 定位标记Location upon delta-T 时差定位Location, clusfer 定位,群集Location,continuous AE signal 定位,连续AE 信号Longitudinal field 纵向磁场Longitudinal magnetization method 纵向磁化法Longitudinal resolution 纵向分辨率Longitudinal wave 纵波 Longitudinal wave probe 纵波探头Longitudinal wave technique 纵波法Loss of back reflection 背面反射损失Loss of back reflection 底面反射损失Love wave 乐甫波Low energy gamma radiation 低能γ辐射Low-enerugy photon radiation 低能光子辐射Luminance 亮度Luminosity 流明Lusec 流西克Maga or million electron volts MeV 兆电子伏特Magnetic history 磁化史Magnetic hysteresis 磁性滞后Magnetic particle field indication 磁粉磁场指示器Magnetic particle inspection flaw indications 磁粉检验的伤显示Magnetic circuit 磁路Magnetic domain 磁畴Magnetic field distribution 磁场分布Magnetic field indicator 磁场指示器Magnetic field meter 磁场计Magnetic field strength 磁场强度(H)Magnetic field/field,magnetic 磁场Magnetic flux 磁通Magnetic flux density 磁通密度Magnetic force 磁化力Magnetic leakage field 漏磁场Magnetic leakage flux 漏磁通Magnetic moment 磁矩Magnetic particle 磁粉Magnetic particle indication 磁痕Magnetic particle testing/magnetic particle ex amination 磁粉检测Magnetic permeability 磁导率Magnetic permeability 磁导率Magnetic pole 磁极Magnetic saturataion 磁饱和Magnetic saturation 磁饱和Magnetic writing 磁写Magnetizing 磁化Magnetizing current 磁化电流Magnetizing coil 磁化线圈Magnetostrictive effect 磁致伸缩效应Magnetostrictive transducer 磁致伸缩换能器 Main beam 主声束Manual testing 手动检测Markers 时标MA-scope; MA-scan MA 型显示Masking 遮蔽Mass attcnuation coefficient 质量吸收系数 Mass number 质量数Mass spectrometer (M.S.)质谱仪Mass spectrometer leak detector 质谱检漏仪 Mass spectrum 质谱Master/slave discrimination 主从鉴别MDTD 最小可测温度差Mean free path 平均自由程Medium vacuum 中真空Mega or million volt MV 兆伏特Micro focus X - ray tube 微焦点X 光管Microfocus radiography 微焦点射线透照术 Micrometre 微米Micron of mercury 微米汞柱Microtron 电子回旋加速器Milliampere 毫安(mA)Millimetre of mercury 毫米汞柱Minifocus x- ray tube 小焦点调射线管Minimum detectable leakage rate 最小可探泄漏率Minimum resolvable temperature difference (MRTD)最小可分辨温度差(MRDT)Mode 波型Mode conversion 波型转换Mode transformation 波型转换Moderator 慢化器Modulation transfer function (MTF)调制转换功能(MTF)Modulation analysis 调制分析Molecular flow 分子流Molecular leak 分子泄漏Monitor 监控器Monochromatic 单色波Movement unsharpness 移动不清晰度Moving beam radiography 可动射束射线透照术Multiaspect magnetization method 多向磁化法Multidirectional magnetization 多向磁化Multifrequency eddy current testiog 多频涡流检测Multiple back reflections 多次背面反射Multiple reflections 多次反射Multiple back reflections 多次底面反射 Multiple echo method 多次反射法Multiple probe technique 多探头法Multiple triangular array 多三角形阵列Narrow beam condition 窄射束NC NCNear field 近场Near field length 近场长度Near surface defect 近表面缺陷Net density 净黑度Net density 净(光学)密度Neutron 中子Neutron radiograhy 中子射线透照Neutron radiography 中子射线透照术Newton (N)牛顿Nier mass spectrometer 尼尔质谱仪Noise 噪声Noise equivalent temperature difference (NE TD)噪声当量温度差(NETD)Nominal angle 标称角度Nominal frequency 标称频率Non-aqueous liquid developer 非水性液体显像剂Non-condensable gas 非冷凝气体Non destructive Examination(NDE)无损试验Non-destructive Examination损检查Nondestructive Evaluation(NDE)无损评价Nondestructive Inspection(NDI)无损检验Nondestructive Testing(NDT)无损检测Nonerasble optical data 可固定光学数据Nonferromugnetic material 非铁磁性材料Non-relevant indication 非相关指示(显示)Non-screen-type film 非增感型胶片Normal incidence 垂直入射(亦见直射声束)Normal permeability 标准磁导率Normal beam method; straight beam method 垂直法Normal probe 直探头Normalized reactance 归一化电抗Normalized resistance 归一化电阻Nuclear activity 核活性Nuclide 核素Object plane resolution 物体平面分辨率Object scattered neutrons 物体散射中子Object beam 物体光束Object beam angle 物体光束角Object-film distance 被检体-胶片距离Object 一film distance 物体- 胶片距离Over development 显影过度Over emulsfication 过乳化Overall magnetization 整体磁化Overload recovery time 过载恢复时间Overwashing 过洗Oxidation fog 氧化灰雾P PPair production 偶生成Pair production 电子对产生Pair production 电子偶的产生Palladium barrier leak detector 钯屏检漏仪Panoramic exposure 全景曝光Parallel scan 平行扫查Paramagnetic material 顺磁性材料Parasitic echo 干扰回波Partial pressure 分压Particle content 磁悬液浓度Particle velocity 质点(振动)速度Pascal (Pa)帕斯卡(帕)Pascal cubic metres per second 帕立方米每秒(Pa?m3/s )Path length 光程长Path length difference 光程长度差Pattern 探伤图形Peak current 峰值电流Peelable developer 可剥离显像剂Penetrameter 透度计Penetrant 渗透剂Penetrameter sensitivity 透度计灵敏度Penetrant 渗透剂Penetrant comparator 渗透对比试块Penetrant flaw detection 渗透探伤Penetrant removal 渗透剂去除Penetrant station 渗透工位Penetrant,water- washable 水洗型渗透剂Penetration 穿透深度Penetrant testing 渗透检测Penetration time 渗透时间Penetrant materials渗透材料Permanent magnet 永久磁铁Permeability coefficient 透气系数Permeability,a-c 交流磁导率Permeability,d-c 直流磁导率Phantom echo 幻象回波Phase analysis 相位分析Phase angle 相位角Phase controlled circuit breaker 断电相位控制器Phase detection 相位检测Phase hologram 相位全息Phase sensitive detector 相敏检波器Phase shift 相位移Phase velocity 相速度Phase-sensitive system 相敏系统Phillips ionization gage 菲利浦电离计Phosphor 荧光物质Photo fluorography 荧光照相术Photoelectric absorption 光电吸收Photographic emulsion 照相乳剂Photographic fog 照相灰雾Photostimulable luminescence 光敏发光Piezoelectric effect 压电效应Piezoelectric material 压电材料Piezoelectric stiffness constant 压电劲度常数Piezoelectric stress constant 压电应力常数 Piezoelectric transducer 压电换能器Piezoelectric voltage constant 压电电压常数 Pirani gage 皮拉尼计Pirani gage 皮拉尼计Pitch and catch technique 一发一收法Pixel 象素Pixel size 象素尺寸Pixel, disply size 象素显示尺寸Planar array 平面阵(列)Plane wave 平面波Plate wave 板波Plate wave technique 板波法Point source 点源Post emulsification 后乳化Post emulsifiable penetrant 后乳化渗透剂Post-cleaning 后清洗Powder 粉未Powder blower 喷粉器Powder blower 磁粉喷枪Pre-cleaning 预清理Pressure difference 压力差Pressure dye test 压力着色检测Pressure probe 压力探头Pressure testing 压力检测Pressure- evacuation test 压力抽空检测Pressure mark 压痕Pressure,design 设计压力Pre-test 初探Primary coil 一次线圈Primary radiation 初级辐射Probe gas 探头气体Probe test 探头检测Probe backing 探头背衬Probe coil 点式线圈Probe coil 探头式线圈Probe coil clearance 探头线圈间隙Probe index 探头入射点Probe to weld distance 探头-焊缝距离Probe/ search unit 探头Process control radiograph 工艺过程控制的射线照相Processing capacity 处理能力Processing speed 处理速度Prods 触头Projective radiography 投影射线透照术Proportioning probe 比例探头Protective material 防护材料Proton radiography 质子射线透照Product family 产品族Pulse 脉冲波Pulse 脉冲Pulse echo method 脉冲回波法Pulse repetition rate 脉冲重复率Pulse amplitude 脉冲幅度Pulse echo method 脉冲反射法Pulse energy 脉冲能量Pulse envelope 脉冲包络Pulse length 脉冲长度Pulse repetition frequency 脉冲重复频率Pulse tuning 脉冲调谐Pump- out tubulation 抽气管道Pump-down time 抽气时间Q factor Q 值Quadruple traverse technique 四次波法Quality (of a beam of radiation) 射线束的质 Quality factor 品质因数Quenching 阻塞Quenching of fluorescence 荧光的猝灭Quick break 快速断间Rad(rad) 拉德Radiance, L 面辐射率,LRadiant existence, M 幅射照度MRadiant flux; radiant power,ψe辐射通量、辐射功率、ψeRadiation 辐射Radiation does 辐射剂量Radio frequency (r- f) display 射频显示Radio- frequency mass spectrometer 射频质谱仪Radio frequency(r-f) display 射频显示Radiograph 射线底片Radiographic contrast 射线照片对比度Radiographic equivalence factor 射线照相等效系数Radiographic exposure 射线照相曝光量Radiographic inspection 射线检测Radiographic inspection 射线照相检验Radiographic quality 射线照相质量Radiographic sensitivity 射线照相灵敏度Radiographic contrast 射线底片对比度Radiographic equivalence factor 射线透照等效因子Radiographic inspection 射线透照检查Radiographic quality 射线透照质量Radiographic sensitivity 射线透照灵敏度Radiography 射线照相术Radiological examination 射线检验Radiology 射线学Radiometer 辐射计Radiometry 辐射测量术Radioscopy 射线检查法Range 量程Rayleigh wave 瑞利波Rayleigh scattering 瑞利散射Real image 实时图像Real-time radioscopy 实时射线检查法Rearm delay time 重新准备延时时间Rearm delay time 重新进入工作状态延迟时间Reciprocity failure 倒易律失效Reciprocity law 倒易律Recording medium 记录介质Recovery time 恢复时间Rectified alternating current 脉动直流电Reference block 参考试块Reference beam 参考光束Reference block 对比试块Reference block method 对比试块法Reference coil 参考线圈Reference line method 基准线法Reference standard 参考标准Reference test piece参考试件Reflection 反射Reflection coefficient 反射系数Reflection density 反射密度Reflector 反射体Refraction 折射Refractive index 折射率Refrence beam angle 参考光束角Reicnlbation 网纹Reject; suppression 抑制Rejection level 拒收水平Relative permeability 相对磁导率Relevant indication 相关指示(显示)Reluctance 磁阻Rem(rem) 雷姆Remote controlled testing 机械化检测Replenisers 补充剂Representative quality indicator 代表性质量指示器Residual magnetic field/field, residual magn etic 剩磁场Residual technique 剩磁技术Residual magnetic method 剩磁法Residual magnetism 剩磁Resistance (to flow)气阻Resolution 分辨力Resonance method 共振法Response factor 响应系数Response time 响应时间Resultant field 复合磁场Resultant magnetic field 合成磁场Resultant magnetization method 组合磁化法 Retentivity 顽磁性Reversal 反转现象Ring-down count 振铃计数Ring-down count rate 振铃计数率Rinse 清洗(冲洗)Rise time 上升时间Rise-time discrimination 上升时间鉴别Rod-anode tube 棒阳极管Roentgen(R) 伦琴Roof angle 屋顶角Rotational magnetic field 旋转磁场Rotational magnetic field method 旋转磁场法 Rotational scan 转动扫查Roughing 低真空Roughing line 低真空管道Roughing pump 低真空泵S SSafelight 安全灯Sampling probe 取样探头Saturation 饱和Saturation,magnetic 磁饱和Saturation level 饱和电平 Scan on grid lines 格子线扫查Scan pitch 扫查间距Scanning 扫查Scanning index 扫查标记Scanning directly on the weld 焊缝上扫查Scanning path 扫查轨迹Scanning sensitivity 扫查灵敏度Scanning speed 扫查速度Scanning zone 扫查区域Scattared energy 散射能量Scatter unsharpness 散射不清晰度Scattered neutrons 散射中子Scattered radiation 散射辐射Scattering 散射Schlieren system 施利伦系统Scintillation counter 闪烁计数器Scintillator and scintillating crystals 闪烁器和闪烁晶体Screen 屏Screen unsharpness 荧光增感屏不清晰度Screen-type film 荧光增感型胶片SE probe SE 探头Search-gas 探测气体Second critical angle 第二临界角Secondary radiation 二次射线Secondary coil 二次线圈Secondary radiation 次级辐射Selectivity 选择性Semi-conductor detector 半导体探测器Sensitirity va1ue 灵敏度值Sensitivity 灵敏度Sensitivity of leak test 泄漏检测灵敏度Sensitivity level (of a penentrant inspection pr ocess) (渗透检测过程的)灵敏度等级Sensitivity control 灵敏度控制Shear wave 切变波Shear wave probe 横波探头Shear wave technique 横波法Shim 薄垫片Shot 冲击通电Side lobe 副瓣Side wall 侧面Sievert(Sv) 希(沃特)Signal 信号Signal gradient 信号梯度Signal over load point 信号过载点Signal overload level 信号过载电平Signal to noise ratio 信噪比Single crystal probe 单晶片探头Single probe technique 单探头法Single traverse technique 一次波法Sizing定量Sizing technique 定量法Skin depth 集肤深度Skin effect 集肤效应Skip distance 跨距Skip point 跨距点Sky shine(air scatter) 空中散射效应Sniffing probe 嗅吸探头Soft X-rays 软X 射线Soft-faced probe 软膜探头Solarization 负感作用Solenoid 螺线管Solvent based developer 溶剂型显像剂Soluble developer 可溶显像剂Solvent remover 溶剂去除剂Solvent-removable penentrant 溶剂去除型渗透剂Solvent cleaners 溶剂清除剂Solvent developer 溶剂显像剂Solvent remover 溶剂洗净剂Solvent-removal penetrant 溶剂去除型渗透剂Sorption 吸着Sound diffraction 声绕射Sound insulating layer 隔声层Sound intensity 声强Sound intensity level 声强级Sound pressure 声压Sound scattering 声散射Sound transparent layer 透声层Sound velocity 声速Source 源Source data label 放射源数据标签Source location 源定位Source size 源尺寸Source-film distance 射线源-胶片距离Spacial frequency 空间频率Spark coil leak detector 电火花线圈检漏仪 Specific activity 放射性比度Specified sensitivity 规定灵敏度Standard 标准Standard 标准试样Standard leak rate 标准泄漏率Standard leak 标准泄漏孔Standard tast block 标准试块 Standardization instrument 设备标准化Standing wave; stationary wave 驻波Step wedge 阶梯楔块Step- wadge calibration film 阶梯楔块校准底片Step- wadge comparison film 阶梯楔块比较底片Step wedge 阶梯楔块Step-wedge calibration film 阶梯-楔块校准片Step-wedge comparison film 阶梯-楔块比较片Stereo-radiography 立体射线透照术Subject contrast 被检体对比度Subsurface discontinuity 近表面不连续性Suppression 抑制Surface echo 表面回波Surface field 表面磁场Surface noise 表面噪声Surface wave 表面波Surface wave probe 表面波探头Surface wave technique 表面波法Surge magnetization 脉动磁化Surplus sensitivity 灵敏度余量Suspension 磁悬液Sweep 扫描Sweep range 扫描范围Sweep speed 扫描速度Swept gain 扫描增益Swivel scan 环绕扫查System exanlillatien threshold 系统检验阈值System inclacel artifacts 系统感生物System noise 系统噪声Tackground, target 目标本底Tandem scan 串列扫查Target 耙Target 靶Testing products 检测产品Television fluoroscopy 电视X 射线荧光检查Temperature envelope 温度范围Tenth-value-layer(TVL) 十分之一值层Test coil 检测线圈Test quality level 检测质量水平Test ring 试环Test block 试块Test frequency 试验频率Test piece 试片Test range 探测范围Test surface 探测面Testing,ulrasonic 超声检测Thermal neutrons 热中子Thermocouple gage 热电偶计Thermogram 热谱图Thermography, infrared 红外热成象Thermoluminescent dosemeter(TLD) 热释光剂量计Thickness sensitivity 厚度灵敏度Third critiical angle 第三临界角Thixotropic penetrant 摇溶渗透剂Thormal resolution 热分辨率Threading bar 穿棒Three way sort 三档分选Threshold setting 门限设置Threshold fog 阈值灰雾Threshold level 阀值Threshotd tcnet 门限电平Throttling 节流Through transmission technique 穿透技术Through penetration technique 贯穿渗透法Through transmission technique; transmission technique 穿透法Through-coil technique 穿过式线圈技术Throughput 通气量Tight 密封Total reflection 全反射Totel image unsharpness 总的图像不清晰度 Tracer probe leak location 示踪探头泄漏定位Tracer gas 示踪气体Transducer 换能器/传感器Transition flow 过渡流Translucent base media 半透明载体介质Transmission 透射Transmission densitomefer 发射密度计Transmission coefficient 透射系数Transmission point 透射点Transmission technique 透射技术Transmittance,τ透射率τTransmitted film density 检测底片黑度Transmitted pulse 发射脉冲Transverse resolution 横向分辨率Transverse wave 横波Traveling echo 游动回波Travering scan; depth scan 前后扫查Triangular array 正三角形阵列Trigger/alarm condition 触发/报警状态 Trigger/alarm level 触发/报警标准Triple traverse technique 三次波法True continuous technique 准确连续法技术Trueattenuation 真实衰减Tube current 管电流Tube head 管头Tube shield 管罩Tube shutter 管子光闸Tube window 管窗Tube-shift radiography 管子移位射线透照术 Two-way sort 两档分选Ultra- high vacuum 超高真空Ultrasonic leak detector 超声波检漏仪Ultrasonic noise level 超声噪声电平Ultrasonic cleaning 超声波清洗Ultrasonic field 超声场Ultrasonic flaw detection 超声探伤Ultrasonic flaw detector 超声探伤仪Ultrasonic microscope 超声显微镜Ultrasonic spectroscopy 超声频谱Ultrasonic testing system 超声检测系统Ultrasonic thickness gauge 超声测厚仪Ultraviolet radiation 紫外辐射Under development 显影不足Unsharpness 不清晰Useful density range 有效光学密度范围UV-A A 类紫外辐射UV-A filter A 类紫外辐射滤片Vacuum 真空Vacuum cassette 真空暗盒Vacuum testing 真空检测Vacuum cassette 真空暗合Van de Graaff generator 范德格喇夫起电机 Vapor pressure 蒸汽压Vapour degreasing 蒸汽除油Variable angle probe 可变角探头Vee path V 型行程Vehicle 载体Vertical linearity 垂直线性Vertical location 垂直定位Viewing 观察Viewing conditions观察条件Visible light 可见光Vitua limage 虚假图像。
渗透探伤工艺规程C&Y2012PT1.主题与适用范围1.1 本规程规定了渗透检测人员的资格、所用器材、检测技术和质量分级等。
1.2 本规程依据JB4730-2005的要求编写。
适用于非多孔性材料或制品开口在工件表面缺陷的检测.2.引用标准JB4730.1-2005《压力容器无损检测》JB4730.5-2005《压力容器无损检测》3.检测人员3.1 检测人员必须经过培训,取得与其工作相适应的资格证书。
从事压力容器检测必须取得锅炉压力容器检测资格证书。
3.2检测人员应每年检查一次视力,矫正视力不小于1.0,不得有色盲和弱视。
3.3 渗透材料易燃、有毒,操作者应佩戴手套、口罩等劳保用品。
4.材料和工具按下列条件和工艺卡要求选择材料和工具。
4.1 渗透检测剂4.1.1 渗透检测剂由渗透剂、清洗剂和显像剂组成,表1的渗透检测剂供选用。
4.1.2 渗透探伤所用的材料,必须采用同一家厂商提供的、同族组产品,不同族组的产品不能混用。
4.1.3 渗透检测剂的鉴定a 生产厂应对每批渗透检测剂的灵敏度和主要性能进行试验,不合格品不能出厂。
进厂的检测剂在低温避光处存放,储存温度15-50℃,并经对比试验合格方可适用。
表1注:对同一检测件,不同类型的检测剂禁止混用b 渗透剂的浓度应根据制造厂说明书的规定进行校验,校验方法按JB4730要求进行。
c 对正在使用的渗透剂做外观检验,如发现有明显混浊或沉淀物,变色或难以清洗,则应予以报废。
4.2 对比试块4.2.1 铝合金对比试块主要用于检验检测剂性能和确定检测工艺参数,其型式如JB4730图12-1所示。
也可切成两块使用。
4.2.2对比试块的清洗和保存对比试块使用后要进行彻底清洗。
清洗通常用丙酮仔细擦洗后再放入装有丙酮和无水酒精的混合液(混合比例1:1)的密闭容器中保存,或使用其他等效方法保存。
4.3 其他材料和工具4.3.1 抹布:清除多余渗透剂的抹布采用干净的棉布、无毛棉纱或吸水纸等。
渗透检测技术规范1.1 检测人员1.1.1从事渗透检测的人员应满足NB/T 47013.1的有关规定。
1.1.2渗透检测人员的未经矫正或经矫正的近(小数)视力和远(距)视力应不低于5.0。
测试方法应符合GB 11533的规定,且应一年检查一次,不得有色盲。
1.2 检测设备和器材1.2.1 渗透检测剂渗透检测剂包括渗透剂、乳化剂、清洗剂和显像剂。
1.2.1.1渗透剂的质量应满足下列要求:a) 在每一批新的合格散装渗透剂中应取出500mL贮藏在玻璃容器中保存起来,作为校验基准;b) 渗透剂应装在密封容器中,放在温度为10℃~50℃的暗处保存,并应避免阳光照射。
各种渗透剂的相对密度应根据制造厂说明书的规定采用相对密度计进行校验,并应保持相对密度不变;c) 散装渗透剂的浓度应根据制造厂说明书规定进行校验。
校验方法是将10mL待校验的渗透剂和基准渗透剂分别注入到盛有90mL无色煤油或其他惰性溶剂的量筒中,搅拌均匀。
然后将两种试剂分别放在比色计纳式试管中进行颜色浓度的比较,如果被校验的渗透剂与基准渗透剂的颜色浓度差超过20%时,就应作为不合格;d) 对正在使用的渗透剂进行外观检验,如发现有明显的混浊或沉淀物、变色或难以清洗,则应予以报废;e) 各种渗透剂用试块与基准渗透剂进行性能对比试验,当被检渗透剂显示缺陷的能力低于基准渗透剂时,应予报废;f) 荧光渗透剂的荧光亮度不得低于基准渗透剂荧光亮度的75%。
试验方法按JB/T 7523中的有关规定执行。
1.2.1.2显像剂的质量控制应满足下列要求:a) 对干式显像剂应经常进行检查,如发现粉末凝聚、显著的残留荧光或性能低下时,应予以报废;b) 湿式显像剂的浓度应保持在制造厂规定的工作浓度范围内,其比重应经常进行校验;c) 当使用的湿式显像剂出现混浊、变色或难以形成薄而均匀的显像层时,则应予以报废。
1.2.1.3 渗透检测剂必须标明生产日期和有效期,并附带产品合格证和使用说明书。
渗透检验作业指导书要点l.工程概况及工程量1.1.工程概况:主要介绍工程名称、规模、特点及施工环境。
1.2.工程量:2.编制依据:列出与渗透探伤相关的所有设计图纸,技术、质量、安环相关的规程、规范。
3.作业前必须具备的条件和应作的准备:3.1技术准备3.1.1接受委托并察看现场(审核委托项目是否齐全、环境条件是否具备)3.1.2根据委托和通用工艺文件编制工艺卡(至少应包括以下方面)采用的渗透液的类型及型号采用的灵敏度试片采用的渗透方法采用的观察和记录方法环境温度及检验参数执行的标准及验收级别安全注意事项3.1.3对作业人员进行安全技术交底.3.1.4选择好渗透探伤剂类型及进行灵敏度校验合格3.1.5辅助工器具及防护用品的准备完毕3.2作业人员(配置、资格)3.2.1 探伤人员必须持有电力工业无损检测人员资格证书,且在有效期内。
探伤报告必需由Ⅱ级或Ⅱ级以上的渗透探伤人员签发。
3.2.2探伤人员矫正视力不得低于1.0,且没有色盲、色弱。
3.2.3 检验辅助工必须经过安全和专业技能培训,合格后方可上岗。
3.2.4. 作业过程中要认真按作业指导书和工艺卡进行检验。
3.2.5. 必须遵守现场安全规程和其它有关规定。
3.2.6. 不具备安全作业条件时探伤人员有权停止工作。
3.2.7. 人员最低配备:持证人员1-2名(Ⅱ级);检验辅助工1-2名3.2.8.作业活动中的组织分工和人员职责3.2.8.1作业的组织分工(与相关作业和其他专业的分工)明确检验委托、检验作业、结果反馈的责任部门和传递渠道。
3.2.8.2作业人员的职责(空表格)列出参加渗透检验工作人员的岗位名称和职责,应包括技术员、班组长、检验作业人员。
3.3作业机具(包括配置、等级、精度等)3.3.2所需仪器、仪表的规格和精度(包括渗透剂、显像剂、温度计等)3.3材料探伤剂、破布、砂纸及相关材料3.5安全器具防护用品及安全帽、防滑鞋、安全带、手套、口罩等劳保用品齐全;施工现场安全设施齐全,照明充足。
船体焊缝无损检测规范20022002年9月1863年纽约立法成立美国航运局船体焊缝无损检测规则规范在1975年最初完成,1986年经再版完善,这个规则是第三版。
本指南旨在介绍更多细节的检查标准和额外的检测技术,它被视为普遍公认的水面舰艇,海洋结构物和其他相关海洋结构建设中的焊缝检查行业作为一种可靠的手段.这个新的标准被作为规范而不是规则的目的是,为了从使用这个规范的工业中收集更多的反馈并且能够及时的对这些反馈在规范中做出修改。
在完成进一步校准期间,这个标准将被作为船体焊缝无损检测规则出版。
ABS 欢迎使用者的问题意见和反馈。
完成日期2002年9月1日第一部分概要1检测准备对焊缝的目测检查必须符合焊接要求,焊缝的准备和清理方法和无损检测产品必须符合要求。
3检测方法放射线,超声波,磁性粒子,液体渗透等被核准的无损检测方法用来对焊缝进行检测。
放射线和超声波用来对内部(表面以下)进行检测。
磁性粒子或液体渗透或者其他符合标准的检测方法一般用来对焊接表面进行检测。
检测的范围和位置和检测方法的选择必须与适用的规则相一致,焊接程序和材料有关,产品的质量管理必须符合要求。
5 人员工作人员使用熟悉的检测设备并且技术和设备需符合要求。
无损检测人员将进行合格的训练并具备检测经验,检测人员必须履行必要的校准规格,认证人员按照国际标准ISO9712 ,培训和认证无损检测人员,应分为下列三个层次的任何一种。
尚未达到认证的人员可能会被列为学员。
5.1 其他公认的国家认证程序必须特别考虑其他公认的国家认证程序的需要。
5.3 无损检测实习生实习生在经过认证人员的监督下单独作业,工作过程中不单独进行任何考核,不用解释测试结果,不用写测试报告,此人可能在注册的过程中得到适当的经验进入1级或直接进入第2级。
5.5 无损检测1级个人认证到无损检测1级可授权:i)装配设备;ii)完成无损检测操作须与二级或三级的书面指导相一致;iii)完成测试;iv)记录测试情况和日期;v) 分类,与事先书面批准的第3级,结果按照标准记录在案,并报告结果。
999 SD00010
液体渗透探伤检验规范
版本 A
翻译肖羽曼
(本规范为英文版的译文,如内容与原版本有出入,以英文版本为准)
翻译日期:2013年12月15日
999 SD00010 A
液体渗透探伤检验规范
1.参考文件
NF EN571-1
NF EN83-100-4
2.表面准备
待检表面应洁净、无油脂、干燥及无任何产物的污染,也没有可能会防止过多渗透剂正确除掉和显示良好反应的不正常情况。
如果达到这些要求,最终和中间(根部焊道或填充焊道)焊缝表面可以保持粗糙状态。
液体渗透检验前的喷砂或喷丸处理只允许在毛坯表面进行。
基础和加工表面粗糙度值应不超到Ra6.3μm,毛坯面或喷丸表面应不超过Ra12.5μm.
3.设备和用品
3.1清洗用品
丙酮或等效特。
3.2渗透剂
在正常照明下有色的、预先乳化的、可水洗去除的渗透剂,型号DP55(Babb公司)或等效物。
可接受的氯化物或硫磺最大含量:200ppm.
3.3去除多余渗透液的用品
水或溶剂。
可接受的最大卤化物含量:25ppm.
3.4显像剂
液体显像剂,型号D100(Babb公司)或等效物。
可接受的氯化物或硫磺最大含量:200ppm.
3.5应用
液体渗透剂应使用:
-喷漆枪或喷雾剂罐进行喷涂。
-刷子或漆刷。
-浸入法。
3.6干燥设备
干燥,清洁和不起毛棉布、纸巾、干燥的去油压缩空气喷头(压力不超过200kPa,即2bar)
4.操作者的资格证明
液体渗透检验操作者应达到欧洲标准NF EN473的Ⅱ级或等效的资格证明。
5.工艺
5.1检验阶段
-制造文件中确定
5.2提供检查的区域
♦厚度≥100mm的所有焊缝边缘表面100%检验。
♦密封焊缝焊道数小于或等于3的100%检验。
如果密封焊缝提出水密性或气密性检查的则不需要
PT检验。
♦所有挖掘表面和返修区域100%检验。
♦吊耳焊缝100%检验。
♦所有其它每种焊缝进行10%检验:拼板焊缝、坡口焊缝……
对于焊缝或返修焊缝,焊缝金属和区域两端应延长10mm进行检验。
5.3零件和用品的温度
-在10℃~50℃之间。
-不可检验的地点:(室外、现场等)
最低温度可能低于5℃,此时应遵循下列特殊要求:
-在低于10℃的特殊检验情况下,显像剂应使用喷雾罐,使用时喷雾罐温度为大约20℃。
而且,应使用风扇加快干燥,如果可能用热风扇,但是零件表面不应超到50℃。
5.4清洗
使用由清洗物质沾湿的海绵或任何其它适当的方法,例如清洗、干的不起毛棉布。
去除清洗剂,自然蒸发干燥。
5.5渗透方法的应用
♦漆刷
♦喷枪或喷雾罐
-停留时间15-60min,对于一些需要更高灵敏性的补充调查,可能需要更长的停留时间。
-预先警告:在整个停留时间里,渗透剂涂层必须保持湿润。
5.6去除多余渗透剂
干扰渗透的多余渗透剂必须完全去除。
但是,不建议过多清洗。
-方法:
♦用喷雾器水洗(水流压力低于200 kPa,即2bar)或海绵,或干净的不起毛棉布。
♦溶剂。
用干净的不起毛棉布去掉最多量的渗透剂,然后以溶剂沾湿的干净不起毛棉布轻轻去除。
禁止将溶剂直接喷射到部件上。
5.7干燥
-清洁干净的不起毛抹布或纸巾。
-干燥的去油压缩空气,压力不大于200kPa(2bar)。
5.8显像剂的应用
-应用阶段:在待检表面干燥后,应立即使用显像剂。
-方法:用喷枪或喷雾罐喷涂。
-显像剂涂层的几何形状:显像剂涂层应薄而均匀。
5.9干燥
-自然蒸发,可用风扇加速蒸发。
6.解释说明
6.1规则说明
显像剂干燥后检验者应立即检查显示情况。
显像剂干燥后,应在不少于10分钟但不超过30分钟内对显示状况做出评价。
一些补充的调查需要更高敏感性,可能需要更长时间。
采取各种措施以便于接近待检零件,确认待检表面有良好可见性和足够光线。
如果使用有色渗透剂,任何自然或人工的光线,除了钠蒸汽灯都是允许的。
待检表面亮度应不低于500Lux。
6.2显示的确认
显示应根据尺寸进行确认。
他们应按线性或弧线分类。
如果它的主要尺寸长度超过较小尺寸的三倍即是线性显示。
其它所有显示均是弧线显示。
6.3验收准则
* 对于完工的合格焊缝:N=5
对于部分位于基体金属的孔洞,验收准则适用坡口验收准则。
对于完全位于焊缝金属的孔洞,所有显示>2 mm可以接收。
注1:验收准则适用于区域检验。
不过,如果在此区域之外发现单独的显示,那种情况下可以应用部件采购的验收准则。
注2:制造者只能焊接表面无显示的焊缝。
密封焊:
焊缝金属:不允许有显示。
焊缝金属附近区域:在宽度等于焊缝理论值厚度(最大5mm),不允许有下列情况:
-长于1.5mm的显示;
-短于1.5mm的显示,如果它们隔开的距离不足3mm。
7.检验后的清洁
液体渗透检验完成后应立即去除所有残留物质。
8.检验报告
任何情况都需要签发报告。
检验报告包括下列信息:
制造单位识别信息、采购订单号和部件或检验焊缝的识别信息,包括材料等级(铁素体或奥氏体不锈钢)和它的制造方法(锻造、辊压、铸造、堆焊、覆层等)
指定使用的检验文件
检验实施所在的产品阶段
表面准备方法(工序和清洗)
液体渗透产品的类型(品牌、类型、标准)
液体渗透检验方法(渗透剂应用方法、停留时间、温度一致性、照明要求)
超出验收准则的所有显示必须进行记录
说明的结果,包括尺寸和不可接受缺陷的位置,如果有必要附简图标出;对于铸件,只需要主要孔洞图
检验人员的姓名和资格证书
实施液体渗透检验的公司(外包部分)
检验日期
日期姓名及一名或多名检查员签名
按照确定的标准给出显示结论。