LD-M冲片机手册
- 格式:doc
- 大小:3.84 MB
- 文档页数:14
印像王-PK冲卡机使用说明书
特点:
该机器是制作名片和PVC证卡的专用工具,可以将塑封好的名片和PVC材料一次裁切成型,定位方便、准确,裁切后的名片无毛边,有直角及工艺圆角,外形美观,是普通裁刀所达不到的,是制作名片和PVC证卡必不可少的配套产品。
操作过程:
1、打开包装,安装好手把;
2、先轻轻搬动手把看转动是否正常;
3、将塑封好的多张名片用裁纸刀切成小于110mm宽后插入切卡机导料槽中,定位
后快速搬动手把;
4、注意裁四压边不能小于3mm,更不能半边及缓慢裁切,否则将会出现毛边或卡
刀弊病;
5、使用本产品,建议用高温胶粘剂的过胶模,否则由于胶质原因可能有微量虚毛;切卡机使用过程中如有螺丝松动,毛边过大或转动部分不灵,用户不得自行拆卸,应及时送回销售点修理。
如发现自行拆装维修过的产品,我单位概不负责。
产品规格:。
ld-md100说明书
第一步:首先我们需要打开电池门装入7号电池,扣动扳机开机通过定位激光瞄准被测物体表面,扣动扳机目标温度就会显示在LCD上,如果松开扳机后温度将保持显示在LCD上。
第二步:按住开关按钮同时将测温仪激光点慢慢上下移动能够进行扫描定位。
第三步:如果红外测温仪突然暴露在环境温差为20℃或更高的情况下,可以允许仪器在20min内调节到新的环境温度。
但红外测温仪不能测量物体内部温度。
要发现热点先要用仪器瞄准目标,然后在目标上作上下扫描运动直至确定热点。
第四步:如果在烟雾等环境等会阻挡仪器的光学系统而影响精确测温,而且它不能透过玻璃进行测温和进行精确温度读数,但我们可通过红外窗口测温。
BEFORE USE ....Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below .If you have any problems or questions with the product, please contact M-System’s Sales Office or representatives. ■PACKAGE INCLUDES:Surge protector ....................................................................(1) ■MODEL NO.Confirm Model No. marking on the product to be exactly what you ordered.■INSTRUCTION MANUALThis manual describes necessary points of caution when you use this product, including installation, connection and basic maintenance procedures.When using this product in potentially explosive atmos-phere or hazardous (classified) location, you have to follow the safety procedure to install it. Please refer to “SAFE IN-STALLATION MANUAL” for each type of certification.LIMITATION APPLICABLE TO M-RESTERThe M-RESTER will protect electronics equipment from damage caused by lightning by absorbing most of the surge voltages.However, M-RESTER may not be effective against cer-tain extremely high voltages caused by a direct or almost direct hit by lightning.M-RESTER must be installed according to this installa-tion / instruction manual.GENERAL■FUNCTION & FEATURES• High discharge current capacity 20 kA (8 / 20 µs), 1 kA (10 / 350 µs)• Ultra-thin 7-mm-wide module can be mounted in high density• Excellent protection employing multi-stage SPD circuits • DIN rail mounting and grounding • Shield terminal provided ■SPECIFICATIONS See Table 1.Table 1. SpecificationsMODEL NO.MD7TC-FFMD7TC-FGMD7TC-GFMD7TC-GGMax. continuous operating voltage (Uc)Line to Line 7.5VLine to Earth ±160V±7.5VLine to SHLD ±160V±7.5VSHLD to Earth ±160Vshort±160Vshort Voltage protection level (Up)@4kV (1.2 / 50 µs)Line to Line 25VLine to Earth ±800V ±25VLine to SHLD ±1200V ±800V ±25VSHLD to Earth ±800Vshort±800VshortLeakage current @Uc Line to Line ≤5µA Other sections ≤5µA Response timeLine to Line ≤4 nsec.Other sections≤20 nsec.Max. discharge current (Imax)20kA (8 / 20 µs), 1.0kA (10 / 350 µs)Nominal current (I N )100mAInternal series resistance 4.7Ω ±10% per line056 222 38 18SEN TRONIC AGPOINTS OF CAUTION■ENVIRONMENT • Indoor use.• When heavy dust or metal particles are present in the air, install the unit inside proper housing with sufficient ventilation.• Do not install the unit where it is subjected to continuous vibration. Do not subject the unit to physical impact.• Environmental temperature must be within -25 to +85°C (-13 to +185°F) with relative humidity within 30 to 90%RH in order to ensure adequate life span and operation.• This unit needs a DIN rail as earth grounding bar. Ox-ide coating of an aluminium rail may lower the electric conductivity between this module and the ground. Use a steel or copper rail. ■DIELECTRIC STRENGTH TESTING• The surge protector starts discharging when 160V or greater voltage (with floating shield type) or several volts (with grounding shield type) is applied between lines and earth. Remove the grounding wire before conducting a test. Be sure to return the wire after the test. ■AND ....• We recommend that you keep spare surge protectors so that you can replace them when necessary .• Lightning surge can enter not only through signal lines but also through power supply lines. We recommend that you also use the L ightning Surge Protector for Power Lines for adequate protection.COMPONENT IDENTIFICATIONINSTALLATIONMount the unit on a DIN rail. Once installed, do not move it to another DIN rail.■MOUNTING THE UNIT ON A DIN RAILA) Hang the upper hook of the DIN rail mounting adaptor at the rear side of unit, on the DIN rail.B) Push in the lower in keeping pressing the unit to the DIN rail.C) DIN rails generally have slight individual variability in size. If you find it difficult to push in the lower part, go back to (A) and hang the upper part more deeply onto the rail and try (B) again.■REMOVING THE UNITA) Push down the spring loader utilizing a minus screwdriv-er.B) Confirm that it is pulled enough down and pull out the lower part of the unit.C) Detach the upper part from the DIN rail.TERMINAL CONNECTIONConnect the unit as in the diagram below .Be sure to ground the DIN rail on which the unit is mounted and cross-wire between the rail and FG terminal of the protected device as shown in Figure 1 in order to equalize the earth potential.When the unit is connected with a device which has no FG terminal, ground the surge protector only . ■EXTERNAL DIMENSIONS unit: mm (inch)8–M3 EURO■Figure 1. GROUNDINGCross-wire from the DIN rail to the metal housing of the protected device to equalize the ground potential.Ground only the surge protector when the protected device has no grounding terminal.■CAUTION WHEN WIRINGHold the module steady at the front when you tighten/loosen screw terminals.■CONNECTION DIAGRAM*1. Oxide film on the surface of an aluminium rail may lower the electric conductivity between this module and the ground.Use a steel or copper rail.*2. Be sure to ground the DIN rail. Recommended grounding resistance ≤100Ω*3. Cross-wire between the DIN rail and the metal housing of the protected device to equalize the earth potential.Ground only the surge protector when the protected device has no ground terminal.*4. Shield wiring method is an example. Proceed according to the system requirements.Sheath orWIRING INSTRUCTIONS■EURO TERMINALTorque: 0.3 N·mApplicable wire size: 0.2 – 2.5 mm2Stripped length: 8 mmMAINTENANCECheck surge protectors periodically. Many cases of light-ning are ignored, and even lightning at a far distance often causes inductive surges.We recommend that you check your surge protector about twice a year, before and after the rainy season. Check whenever you experience a strong lightning occurrence. Checking procedure is explained in the following:■CHECKINGWIRING1) Make sure that wiring is done as instructed in the con-nection diagram.2) Make sure that the DIN rail is connected to the metal enclosure of protected device.3) Make sure that the surge protector is securely attached to the DIN rail, and that the rail is grounded to earth.DISCHARGE ELEMENT1) Remove all wiring connected to the surge protector when you test the module.2) Check resistance across the terminals indicated in Table 2 on the high resistance range of multimeter and confirm no conduction. The tester should show 10 MΩ or greater.3) Confirm conduction across the same terminals with a 500 V DC 1000 MΩ insulation tester. The tester should show 20 MΩ or less.4) If any of the above tests shows negative, replace the surge protector.Table 2.TERM.MODEL MD7TC-FF MD7TC-FG MD7TC-GF MD7TC-GG4 – 5Yes Yes Yes Yes4 – 8No Yes Yes Yes5 – 8No Yes Yes Yes8 – 5No No Yes Yes5 – DIN rail Yes Yes No Yes8 – DIN rail Yes No Yes No Note 1: A pply (+) voltage of the multimeter to the terminal number indicated on the left side.Note 2: Polarity does not matter for the insulation tester.。
****************LDM-A1 SeriesDigital microscope LDM-A1 series allows person to view the sample without straining the eyes because of which quantitative analysis of samples at microscopic level is possible. It comes with advanced technology LCD TFT touch screen for high resolution image of the specimen. We can obtain clear and sharp images of the specimen using coarse and fine focusing adjustment mechanism.Digital microscope has wide and promising applications in the fields of bacteriology, cytolo -gy, botany, medical research field to study the details of the specimen on LCD screen.FeaturesApplicationsSpecificationsDigital Microscope LDM-A1 SeriesInfinite optical systemAndroid 4.2.2 O.S. with 5.0 mega pixel LCD TFT screen resolution Infinity plan achromatic objective3W LED lamp with intensity control for illumination Advanced technology software IMS camera, Touch scope Model No.Optical system Viewing headEyepieceObjectives StageTrinocular head, inclined at 300, interpupillary distance 54 mm-75 mmSiedentopf type binocular head , inclined at 300, 3600eyepiece tube rotation,interpupillary distance50 mm-75 mm, anti-fungal system High eye point wide fieldplan eyepiece PL10X/22 mm,with ±5 diopter controlCoaxial mechanical stage:140 mm130 mm, Travel stage:76 mm x 50 mmDouble layer mechanical stage: 180 mm x 145 mm, Travel stage: 56 mm x 75 mm with right hand stage handleWF10XInfinity plan achromatic objective: 4x, 10x, 40x(s), 100x(s, Oil)Infinite optical systemLDM-A10LDM-A11CondenserFocusingNosepieceIlluminationLCD Screen OutputTouch scopeDark field slider for condenser Simple polarization(with analyzer & polarizer)Phase contrast kit (10x, 20x, 40x, 100x)Operating system Software Valid Pixel Power supplyKohler N.A. 1.25 condenser (with socket for phasecontrast & dark field sliders)Abbe type N.A. 1..25 condenser with iris diaphragm Coarse and fine focusing adjustment with limited and tension adjustment. Coarse adjustment range 25mm,fine adjustmentprecision:0.002 mm Coarse and fine focusing adjustment with rack and pinion mechanism, finefocusing interval 0.002 mmMain supply 100V~240V,3W LED lamp with intensity control (fixed center)9.7 inch TFT touch screen USB 2.0, HDMI Android 4.2.2IMS camera 5.0 Mega pixel85V~265V universal power supply 8 inch TFT touch screenBuilt-in kohler illumination system 3W LED, adjustable brightness, field diaphragm Quintuple quick-stop revolving mechanism with multiple ball bearingBackward quadruple nosepieceSD cardOptional accessory。
键盘图标及功能说明A. 键盘左上方之喂版灯FEED此灯在闪亮时表示机器已进入待机状态,可开始喂版。
此灯不亮表示显影温度未到达设定值范围,或进版感应器正在感应中,此时不可喂版。
B. 键盘第一排之显示器TEMP.℃用于所有温度之显示或设定之用。
正常情况下是显示现在之实际显影温度。
C. 键盘第二排之显示器COUNTER DEV TIME用于所有不是温度之显示或设定之用。
正常情况下是显示现在之实际显影时间。
D. 行程显示灯DEV WASH GUM DRYER在第二排显示器下和数字键中间之灯号。
相对应显示版材行程在”显影””水洗”“上胶”“烘干”之位置。
E. 蜂鸣器蜂鸣器依以下之状态产生不同之鸣声次数:F. 触摸面版使用触摸键可设定机器所需之各种数值。
包含“显影时间”、“显影温度”、“烘干温度”、“日间氧化补充”、“夜间氧化补充”、“黑化补充”等。
触摸面版按键之功能和作用:按键按键功能:1.代码:(1.DEV.T) 数字"1";显影时间选项。
2.代码:(2.DEV.C) 数字"2";显影温度选项。
3.代码:(3.DRY.C) 数字"3";烘干温度选项。
4.代码:(4.D.AC.) 数字"4";日间氧化补充选项。
(显影) 5.代码:(5.N.AC.) 数字"5";夜间氧化补充选项。
(显影) 6.代码:(6.AB) 数字"6";冲版消耗补充选项。
(显影) 7. 代码:(7.MREP) 数字"7";手动补充选项。
(显影)8.代码:(8.MO.W) 数字"8";手动进水洗之清水。
9.代码:(9.D/N) 数字"9";开关机键。
按一次开(灯亮)。
再按一次关(灯熄)。
0.代码:(0.LOCK) 数字"0";使所有显示灯亮或灭。
QDPC-90气动冲片机使用说明QDPC-90气动冲片机供橡胶厂及科研单位进行拉力试验前冲切标准橡胶试片及类似材料。
气动控制,操作方便、快捷、省力。
一、技术参数:1.最大行程:100mm2.工作台尺寸:300mm×300mm3.有效面积:30mm×200mm4.外形尺寸:400mm×300mm×800mm5.工作气压:0.4MPa6.重量:50Kg好仪器,好资料,尽在沧州建仪()。
欢迎查询。
打造中国建仪销售第一品牌,树立沧州工业产品全新形象二、选配器具:I型(哑铃型)总长L=120mm端部宽度b=25±0.5mm标距Lο=40mmⅡ型(哑铃型)总长L=115m端部宽度b=25±1mm标距Lο=25mmⅢ型(哑铃型)总长L=150mm端部宽度b=10±0.5mm标距Lο=50mmⅣ型(哑铃型)总长L=不小于150mm端部宽度b=10-25mm标距Lο=50mm三、注意事项:1.切片开始前检查冲片机工作区域,确保无异物。
2.冲切裁刀刀刃平面应与试样板平行,冲切时裁刀刀刃禁止接触底板,以免损伤刀刃。
3.冲切裁刀经使用后,应涂上防锈油,以防锈蚀。
4.定期给气压调节器加注润滑油。
5.禁止多人同时操作机器,或将手指放置在冲片机移动机台工作区域,以免伤害人体。
6.停止使用时,需切断电源,防止碰触。
四、操作规程:1.连接好空压机。
2.检查并清理冲片机下压工作区。
3.将塑料垫板平放入冲片机下工作台,将试样放在塑料垫板上。
4.将裁刀平稳放在试样上(裁刀刀刃朝试样放置),尽量使裁刀背部放置在冲片机移动机台中心区域。
5.按下冲片机前面的红色按钮,冲片机移动机台开始往下压。
压到试样后稍作停留,松开红色按钮,冲片机移动机台上升。
取出试样。
BLF8G22LS-205VPower LDMOS transistorRev. 2 — 1 September 2015Product data sheet 1. Product profile1.1General description205W LDMOS power transistor with improved video bandwidth for base stationapplications at frequencies from 2100MHz to 2200MHz.Table 1.Typical performanceTypical RF performance at T case = 25 ︒C in a common source class-AB production test circuit.Test signal f I Dq V DS P L(AV)G pηD ACPR5M(MHz)(mA)(V)(W)(dB)(%)(dBc)1-carrier W-CDMA2110to21701500285018.332.5-32 [1][1]Test signal: 3GPP test model 1; 64 DPCH; PAR = 7.2 dB at 0.01% probability on CCDF.1.2Features and benefits⏹Excellent ruggedness⏹High efficiency⏹Low thermal resistance providing excellent thermal stability⏹Designed for broadband operation⏹Lower output capacitance for improved performance in Doherty applications⏹Designed for low memory effects providing excellent pre-distortability⏹Internally matched for ease of use⏹Integrated ESD protection⏹Compliant to Directive 2002/95/EC, regarding Restriction of Hazardous Substances(RoHS)1.3Applications⏹RF power amplifiers for base stations and multi carrier applications in the2100MHz to2200 MHz frequency range2. Pinning information[1]Connected to flange.3. Ordering information4. Limiting values[1]Continuous use at maximum temperature will affect the reliability, for details refer to the on-line MTF calculator.5. Thermal characteristicsTable 2.PinningTable 3.Ordering informationType number PackageName DescriptionVersion BLF8G22LS-205V-earless flanged LDMOST ceramic package; 6leadsSOT1239BTable 4.Limiting valuesIn accordance with the Absolute Maximum Rating System (IEC 60134).Symbol ParameterConditions Min Max Unit V DS drain-source voltage -65V V GS gate-source voltage -0.5+13V T stg storage temperature -65+150︒C T jjunction temperature[1]-225︒CTable 5.Thermal characteristics Symbol ParameterConditionsTyp Unit R th(j-c)thermal resistance from junction to caseT case =80︒C; P L =56W;V DS =28V;I Dq =1200mA0.26K/W6. Characteristics7. Test information7.1Ruggedness in Doherty operationThe BLF8G22LS-205V is capable of withstanding a load mismatch corresponding toVSWR =10: 1 through all phases under the following conditions: V DS =28V; I Dq =1200mA; P L =140W (W-CDMA); f =2110MHz.Table 6.DC characteristicsT j = 25 ︒C, unless otherwise specified.Symbol Parameter ConditionsMin Typ Max Unit V (BR)DSS drain-source breakdown voltage V GS =0V; I D =3.3mA65--V V GS(th)gate-source threshold voltage V DS =10V; I D =330mA 1.5 1.9 2.3V V GSq gate-source quiescent voltage V DS =28V; I D =1650mA 1.7 2.1 2.5V I DSS drain leakage current V GS =0V; V DS =28V -- 3.6μA I DSX drain cut-off current V GS =V GS(th)+3.75 V; V DS =10V-60-A I GSS gate leakage current V GS =11V; V DS =0V --360nA g fs forward transconductanceV DS =10V; I D =330mA- 2.9-S R DS(on)drain-source on-state resistance V GS =V GS(th) + 3.75V;I D =11.6A-0.04-ΩTable 7.RF characteristicsTest signal: 1-carrier W-CDMA; PAR =7.2dB at 0.01% probability on CCDF; 3GPP test model 1; 64 DPCH; f 1=2110MHz;f 2=2170MHz; RF performance at V DS =28V;I Dq =1200mA; T case =25︒C; unless otherwise specified; in a production circuit.Symbol Parameter Conditions Min Typ Max Unit G p power gain P L(AV)=50.1W 17.118.3-dB ηD drain efficiency P L(AV)=50.1W 27.532.5-%RL in input return lossP L(AV)=50.1W --10-6dB ACPRadjacent channel power ratioP L(AV)=50.1W--30-25dBc7.2Impedance informationTable 8.Typical impedanceMeasured load-pull data; I Dq = 1800 mA; V DS = 28 V; typical values unless otherwise specified.f Z S [1]Z L[1]P L [2]ηD [2]G p [2](MHz)(Ω)(Ω)(W)(%)(dB)Maximum power load2110 1.80 - j4.05 1.2 - j2.7556.0056.6115.572140 2.24 - j5.00 1.2 - j2.7555.9555.8515.712170 2.90 - j4.50 1.2 - j2.7555.8856.0516.03Maximum drain efficiency load2110 1.80 - j4.05 1.60 - j1.3454.0865.8418.122140 2.24 - j5.00 1.52- j1.5754.3864.8818.062170 2.90 - j4.50 1.41 - j1.7754.5864.2418.08[1]Z S and Z L defined in Figure1.[2]at 3 dB gain compression7.3VBW in a class-AB operationThe BLF8G22LS-205V shows 110MHz (typical) video bandwidth in class-AB test circuit in 2140 MHz at V DS = 28 V; I Dq = 1500 mA.7.4Test circuitTable 9.List of componentsSee Figure2 for component layout.Component Description Value Remarks C1, C2, C3, C4, C5, C6multilayer ceramic chip capacitor20pFC7, C8, C9, C10, C11,multilayer ceramic chip capacitor10 μF, 50V C12, C14, C16C13, C15multilayer ceramic chip capacitor 1 μF, 50vC17, C18electrolytic capacitor2200 μF, 63VR1, R2chip resistor 5.1 Ω7.5Graphical data 7.5.1Pulsed CW7.5.2CW7.5.31-Carrier W-CDMA7.5.42-Tone VBW8. Package outlineFig 9.Package outline SOT1239B9. Handling information10. Abbreviations11. Revision historyTable 10.AbbreviationsAcronym Description3GPP 3rd Partnership Project CW Continuous WaveCCDF Complementary Cumulative Distribution Function DPCH Dedicated Physical CHannel ESD ElectroStatic DischargeLDMOS Laterally Diffused Metal-Oxide SemiconductorLDMOST Laterally Diffused Metal-Oxide Semiconductor Transistor MTF Median Time to Failure PAR Peak-to-Average Ratio VBW Video BandWidthVSWR Voltage Standing Wave RatioW-CDMAWideband Code Division Multiple AccessTable 11.Revision historyDocument ID Release date Data sheet status Change notice Supersedes BLF8G22LS-205V v.220150901Product data sheet-BLF8G22LS-205V v.1Modifications:•The format of this document has been redesigned to comply with the new identity guidelines of Ampleon•Legal texts have been adapted to the new company name where appropriateBLF8G22LS-205V v.120150901Product data sheet--12. Legal information12.1 Data sheet status[1]Please consult the most recently issued document before initiating or completing a design.[2]The term ‘short data sheet’ is explained in section “Definitions”.[3]The product status of device(s) described in this document may have changed since this document was published and may differ in case of multiple devices. The latest product statusinformation is available on the Internet at URL .12.2 DefinitionsDraft — The document is a draft version only. The content is still under internal review and subject to formal approval, which may result in modifications or additions. Ampleon does not give any representations or warranties as to the accuracy or completeness of information included herein and shall have no liability for the consequences of use of such information.Short data sheet — A short data sheet is an extract from a full data sheet with the same product type number(s) and title. A short data sheet is intended for quick reference only and should not be relied upon to contain detailed and full information. For detailed and full information see the relevant full data sheet, which is available on request via the local Ampleon sales office. In case of any inconsistency or conflict with the short data sheet, the full data sheet shall prevail.Product specification — The information and data provided in a Product data sheet shall define the specification of the product as agreed between Ampleon and its customer, unless Ampleon and customer have explicitly agreed otherwise in writing. In no event however, shall an agreement be valid in which the Ampleon product is deemed to offer functions and qualities beyond those described in the Product data sheet.12.3 DisclaimersLimited warranty and liability — Information in this document is believed to be accurate and reliable. However, Ampleon does not give any representations or warranties, expressed or implied, as to the accuracy or completeness of such information and shall have no liability for the consequences of use of such information. Ampleon takes no responsibility for the content in this document if provided by an information source outside of Ampleon.In no event shall Ampleon be liable for any indirect, incidental, punitive, special or consequential damages (including - without limitation - lost profits, lost savings, business interruption, costs related to the removal or replacement of any products or rework charges) whether or not such damages are based on tort (including negligence), warranty, breach of contract or any other legal theory.Notwithstanding any damages that customer might incur for any reason whatsoever, Ampleon’s aggregate and cumulative liability towards customer for the products described herein shall be limited in accordance with the Terms and conditions of commercial sale of Ampleon.Right to make changes — Ampleon reserves the right to make changes to information published in this document, including without limitation specifications and product descriptions, at any time and without notice. This document supersedes and replaces all information supplied prior to the publication hereof.Suitability for use — Ampleon products are not designed, authorized or warranted to be suitable for use in life support, life-critical or safety-critical systems or equipment, nor in applications where failure or malfunction of an Ampleon product can reasonably be expected to result in personal injury, death or severe property or environmental damage. Ampleon and its suppliers accept no liability for inclusion and/or use of Ampleon products in such equipment or applications and therefore such inclusion and/or use is at the customer’s own risk.Applications — Applications that are described herein for any of these products are for illustrative purposes only. Ampleon makes no representation or warranty that such applications will be suitable for the specified use without further testing or modification.Customers are responsible for the design and operation of their applications and products using Ampleon products, and Ampleon accepts no liability for any assistance with applications or customer product design. It is customer’s sole responsibility to determine whether the Ampleon product is suitable and fit for the customer’s applications and products planned, as well as for the planned application and use of customer’s third party customer(s). Customers should provide appropriate design and operating safeguards to minimize the risks associated with their applications and products.Ampleon does not accept any liability related to any default, damage, costs or problem which is based on any weakness or default in the customer’s applications or products, or the application or use by customer’s third party customer(s). Customer is responsible for doing all necessary testing for the customer’s applications and products using Ampleon products in order to avoid a default of the applications and the products or of the application or use by customer’s third party customer(s). Ampleon does not accept any liability in this respect.Limiting values — Stress above one or more limiting values (as defined in the Absolute Maximum Ratings System of IEC60134) will cause permanent damage to the device. Limiting values are stress ratings only and (proper) operation of the device at these or any other conditions above those given in the Recommended operating conditions section (if present) or the Characteristics sections of this document is not warranted. Constant or repeated exposure to limiting values will permanently and irreversibly affect the quality and reliability of the device.Terms and conditions of commercial sale — Ampleon products are sold subject to the general terms and conditions of commercial sale, as published at /terms, unless otherwise agreed in a valid written individual agreement. In case an individual agreement is concluded only the terms and conditions of the respective agreement shall apply. Ampleon hereby expressly objects to applying the customer’s general terms and conditions with regard to the purchase of Ampleon products by customer.No offer to sell or license — Nothing in this document may be interpreted or construed as an offer to sell products that is open for acceptance or the grant, conveyance or implication of any license under any copyrights, patents or other industrial or intellectual property rights.Export control — This document as well as the item(s) described herein may be subject to export control regulations. Export might require a prior authorization from competent authorities.Document status[1][2]Product status[3]DefinitionObjective [short] data sheet Development This document contains data from the objective specification for product development. Preliminary [short] data sheet Qualification This document contains data from the preliminary specification.Product [short] data sheet Production This document contains the product specification.Non-automotive qualified products — Unless this data sheet expressly states that this specific Ampleon product is automotive qualified, the product is not suitable for automotive use. It is neither qualified nor tested in accordance with automotive testing or application requirements. Ampleon accepts no liability for inclusion and/or use of non-automotive qualified products in automotive equipment or applications.In the event that customer uses the product for design-in and use in automotive applications to automotive specifications and standards, customer (a) shall use the product without Ampleon’ warranty of the product for such automotive applications, use and specifications, and (b) whenever customer uses the product for automotive applications beyond Ampleon’ specifications such use shall be solely at customer’s own risk, and (c) customer fully indemnifies Ampleon for any liability, damages or failed product claims resulting from customer design and use of the product for automotive applications beyond Ampleon’ standard warranty and Ampleon’ product specifications.Translations — A non-English (translated) version of a document is for reference only. The English version shall prevail in case of any discrepancy between the translated and English versions.12.4 TrademarksNotice: All referenced brands, product names, service names and trademarks are the property of their respective owners.Any reference or use of any ‘NXP’ trademark in this document or in or on the surface of Ampleon products does not result in any claim, liability or entitlement vis-à-vis the owner of this trademark. Ampleon is no longer part of the NXP group of companies and any reference to or use of the ‘NXP’ trademarks will be replaced by reference to or use of Ampleon’s own trademarks.13. Contact informationFor more information, please visit: For sales office addresses, please visit: /sales14. Contents1 Product profile. . . . . . . . . . . . . . . . . . . . . . . . . . 11.1 General description . . . . . . . . . . . . . . . . . . . . . 11.2 Features and benefits. . . . . . . . . . . . . . . . . . . . 11.3 Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Pinning information. . . . . . . . . . . . . . . . . . . . . . 23 Ordering information. . . . . . . . . . . . . . . . . . . . . 24 Limiting values. . . . . . . . . . . . . . . . . . . . . . . . . . 25 Thermal characteristics . . . . . . . . . . . . . . . . . . 26 Characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . 37 Test information. . . . . . . . . . . . . . . . . . . . . . . . . 37.1 Ruggedness in Doherty operation . . . . . . . . . . 37.2 Impedance information. . . . . . . . . . . . . . . . . . . 47.3 VBW in a class-AB operation. . . . . . . . . . . . . . 47.4 Test circuit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57.5 Graphical data . . . . . . . . . . . . . . . . . . . . . . . . . 67.5.1 Pulsed CW . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67.5.2 CW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67.5.3 1-Carrier W-CDMA . . . . . . . . . . . . . . . . . . . . . . 77.5.4 2-Tone VBW. . . . . . . . . . . . . . . . . . . . . . . . . . . 88 Package outline. . . . . . . . . . . . . . . . . . . . . . . . . 99 Handling information. . . . . . . . . . . . . . . . . . . . 1010 Abbreviations. . . . . . . . . . . . . . . . . . . . . . . . . . 1011 Revision history. . . . . . . . . . . . . . . . . . . . . . . . 1012 Legal information. . . . . . . . . . . . . . . . . . . . . . . 1112.1 Data sheet status . . . . . . . . . . . . . . . . . . . . . . 1112.2 Definitions. . . . . . . . . . . . . . . . . . . . . . . . . . . . 1112.3 Disclaimers. . . . . . . . . . . . . . . . . . . . . . . . . . . 1112.4 Trademarks. . . . . . . . . . . . . . . . . . . . . . . . . . . 1213 Contact information. . . . . . . . . . . . . . . . . . . . . 1214 Contents. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13Please be aware that important notices concerning this document and the product(s)described herein, have been included in section ‘Legal information’.© Ampleon Netherlands B.V.2016.All rights reserved.For more information, please visit: For sales office addresses, please visit: /sales。
1.5 m (4.9 ft.) Cable-Management Sleeve - Spiral -45 mm (1.8 in.) DiameterProduct ID: CMSCOILED3Here’s a fast, easy solution to organizing your cables. This spiral cable management sleeve wraps around your cables to tidy up your work area, while protecting your cords from abrasion. The expandable sleeve is conveniently sized:•45 mm Diameter x 1.5 m Length (1.8" x 4.9')This coiled cable sleeve is also available in other diameters and lengths to suit your needs:•25 mm Diameter x 1.5 m Length (1" x 4.9') - CMSCOILED•25 mm Diameter x 2.5 m Length (1" x 8.2') - CMSCOILED2•45 mm Diameter x 2.5 m Length (1.8" x 8.2') - CMSCOILED4Flexible and ExpandableThe flexible and expandable cable cord organizer will hold multiple cables and gauges, from thin phone chargers to thick power cords. Create a tidy workspace in minutes to keep your cables neat, and still accessible, within the attractive coiled sleeve. It’s a great way to provide a neat appearance for cables and equipment wiring in offices, lobbies, boardrooms, and customer-facing areas.Protect your WiringKeeping your cables in a cable management sleeve keeps them concealed, and protects them from wear and tear under your TV or desk.Add or Remove Cables Any TimeOpen up the side of the cable tube concealer any time, to access, add or remove cables. You can also create a breakout of cables at any point in the sleeve to re-route or replace cables.Fast and Easy SetupThe wire management sleeve comes with a time-saving cable loading tool. You simply slide the tool along the spiral wrap to guide your cables through the cable hider sleeve. You can also trim the sleeve to the desired length.ReusableMade of durable polyethylene, the cable cover sleeve is easily reusable.CMSCOILED3 is backed by a 2-year warranty and free, lifetime technical support.Certifications, Reports and Compatibility Applications•Organize and protect your cables and wiring in offices and sharedworkstations•Give visible wiring a neat appearance in lobbies, boardrooms, and customer facing areasFeatures•Keeps your cables neat and organized, while protecting from abrasion•Fast and easy setup, with cable loading tool included•Flexible and expandable spiral wrap fits many cables, from thin phone chargers to thick power cords•Add or remove cables easily any time•Re-usable sleeve made of durable polyethyleneWarranty 2 YearsColor BlackPhysicalCharacteristicsMaterial PolyethyleneProduct Height45.000Product Length59.1 in [150 cm]Product Width45.000Weight of Product301.000Package Height 1.6 in [40 mm]PackagingInformationPackage Length18.1 in [460 mm]Package Width13.4 in [340 mm]Shipping (Package) Weight12.2 oz [345 g]What's in the Box Included in Package 1 - Cable-Management Sleeve1 - Cable Insertion Tool1 - Quick-Start Guide Product appearance and specifications are subject to change without notice.。
LDM320-5型离线低压脉冲清灰袋式除尘器产品使用说明书目录1.基本特点 12.基本结构及工作原理 13.设备技术性能 14.发运,安装,调试 25.维护和检修 26.易损件外购件明细 37.图1:基本结构图 48.图2:外形尺寸图 51.基本特点本除尘器用离线低压脉冲喷吹清灰的方式来强化清灰效果.采用离线清灰可以给被从滤袋抖动下落的粉尘一段沉降时间,防止二次扬尘,延长清周期.延长清灰周期可减少滤袋拍打次数,延长滤袋寿命并降低动力损耗.滤袋骨架螺旋弹性结构,整体除下部底盘外再无其它焊点,因而不存在焊豆、焊渣、尖锋等庇病.同样是提高滤袋使用寿命的重要措施.采用螺旋弹性骨架可以实现室内换袋,每个室只设一个小孔人孔门,与每个室排列检查门相比可以减少漏风率,另外还能降低因拆卸和按装检查门的劳动强度.采用淹没式低压脉冲阀可减少阀体自身阻力,适用于供气网路压力不稳定场合,并可延长膜片使用寿命.2基本结构及工作原理2.1基本结构除尘器其本结构至下而上分别由排灰装置下部机体(包括:钢结构支架、灰斗、下部吊袋框架、灰斗人孔门)、上部机体(包括:过滤室、净气室、花板及进风箱、出风箱、顶盖人孔门)、脉冲清灰装置、滤袋及骨架、离线装置几大部组成.2.2工作原理烟气在风机的作用下从除尘器进风口进入除尘器下部机体,由于风速降低大颗粒粉尘沉降在灰斗内,烟气上升碰撞滤袋受阻,粉尘被捕获覆着于滤袋外表面,气体通过滤料被净化经净气室出口及管路风机排至大气.当除尘器阻力达到额定值时其中一个室的气缸向下推动阀板关闭排风口,该室停止过滤处于非负压状态.稍后启动脉冲阀对每排滤袋依次进行脉冲喷吹,剧烈抖动滤袋使滤料表面积尘脱落沉降.脉冲喷吹后延时20s气缸复位打开排风口,该室恢复过滤状态.延时一定时间后下一室依照上述程序执行.清灰与过滤是在各室间交替进行.沉降在灰斗中的粉尘由螺旋输送机及排灰阀排出.3.设备技术参数1.室数:5室2.滤袋条数:225条3.滤袋规格:ф130x35404.净过滤面积:256m²5.全过滤面积:320m²6.脉冲阀规格:3英寸7.脉冲阀数量:15件.8.脉冲阀应用压缩空气压力:≤0.35MPa.9.脉冲阀压缩空气耗量:≤250L/阀.次.10.离线阀气缸应用压缩空气压力:≥0.4MPa.11.工作温度:≤120º/≤200ºC两挡.根据所选用滤料材质确定.12.设备阻力:≤1470Pa.13.排放浓度:≤60mg/Nm%*p3%*p%*b.14.处理风量:≤23000m%*p3%*p%*b/h.4.发货、安装、及调试.4.1发货根据运输条件,设备解体状态发货.4.2安装设备安装可按下列顺序进行:4.2.1.首先检查设备基础,按常规清理,放线.4.2.1.将下部机体就位,要求平面水平,轴心垂直.4.2.3按装上部机体,调准位置,与下部联连续焊接,保证严密.4.2.4用户自备并按装检修平台,爬梯/护栏.4.2.5封好盖板,保证严密.4.2.6安装布袋及滤袋骨架.安装前检查滤袋上口涨圈凹槽与花板孔尺寸是否合适,滤袋上口外尺寸太大则滤袋与花板孔之间出现缝隙.滤袋上口外尺寸太小将出现掉袋现象.滤袋受扭距不得转动,受500N拉力不得脱落.第一步按滤袋及滤袋骨架装配要求装配其本体.在与花板安装时,先将下端输入花板孔,再向上用力拉上端使螺距增大,在螺距中缝隙处压扁袋子口涨圈口尺寸小于花板孔直径,将滤袋上端凹口对准花板孔后松开,完成滤袋与花板的固定.下端软钢丝向下拉紧缠缚于吊袋架上.4.2.7安装脉冲喷吹装置/气动装置及气路元件.4.3调试4.3.1.在除尘器内部调试、检修、换滤袋的全部过程中除尘主风机绝对不允许启动运行,防止气流伤人.4.3.2.首先调试气缸提升阀的高度,保证提升阀的胶板下平面与排风孔板上平面的距离为195mm,可以通过气缸缸杆端的节流螺母进行调节.关闭阀门时胶板必需压紧盖严排风孔口.4.3.2调整排灰设备,保证密封处密封严密,运动部件无异常音响/振动和卡壳现象.4.3.3.调整清灰系统,要求气缸提升阀/电磁脉冲阀动作顺序正确,时间准确.反吹阀开闭灵活,关阀时胶板压严压紧阀口.操作员的眼睛不得近距离直视气动换向排气孔,防止高压气流伤害.4.3.4进行空载和负荷调试.4.3.4.1.进行空载和负荷调试前必需对除尘器内部进行彻底清理.除净一切杂物,4.3.4.2接通全部电源,压缩空气气源,先手动启动排灰设备和清灰装置.确认没有问题后,启用自动程序.4.3.4.3启动主风机,观察空载运行阻力.产尘点吸风状态,调整调风阀开度,提高吸风质量.计算漏风率,漏风率不大于3%.否则应进行处理.4.3.4.4启动全部工艺设备,通入尘气,观察除尘器运行阻力上升情况及排放口的排放情况,在新滤袋未形成滤尘膜前排放口将会有微量粉尘逸出,这是正常现象,会自动消除.5.维护和检修.5.1.设备运行应设专人管理,并作好运行记录.5.2.凡轴承等运动部件应按规定注油或换油,发现不正常现象及时排除.气动装置前端分水/减压/油雾三联体中油雾杯保持始终存储机油.5.3.气动三连体中的气水分离器应及时排污,同时气水分离器应每隔绝3-6个月清洗一次.5.4.定期检查气路系统/排灰系统工作情况,发现异常应及时处理.5.5.当除尘器正常运行后出现烟囱冒烟或除尘器阻力大幅下降,表明滤袋破损,应及时更换滤袋.5.6.人孔门密封条老化或损坏及时更换.5.7.定期检查气路系统/排灰系统工作情况,发现异常应及时处理.5.8.开机时,应先接通压缩空气至储气包,接通控制器电源,启动排灰装置,如果系统中还有其他设备,应先启动下游设备.5.9.停机时,在工艺系统停止以后,应何持除尘器和排风机继续工作一段时间,以除去设备内的潮气和粉尘.以防止糊袋.6.主要易损件外购件明细:6.1.气缸规格型号:QGBⅡMF1-ф80x200(气缸杆加长130mm). 数量:5件.6.2.两位五通阀规格型号:2637.0201.(DC24V). 数量:5件.6.3.快插接头8. 数量:30件.6.4.消音器.(与6.2项配套)数量:10件.6.5.耐压输气胶管8. 数量:9m.注释:6.1-6.4项各件联接螺纹尺寸要统一,6.3项之内孔与6.5项管外径要匹配.6.6.过滤/减压/油雾三联体规格型号:398-15. 数量:1件.6.7.过滤/减压二联体规格型号:397-25. 数量:1件.以上配件生产单位:辽宁风城市辽兴气动成套总厂.6.8:300x300星形卸料阀型号:YJD-16 数量:1台.6.8.淹没式3英寸低压电磁脉冲阀上体(包含电磁阀至膜片及螺栓垫圈)型号:DYM89A. 数量:15件.生产单位:沈阳石油机械有限公司.。
Membrane air dryers LDM1, D seriesProduct range overview D series service units, metal design2è Internet: /catalog/...Subject to change – 2015/032015/03 – Subject to change 3è Internet: /catalog/...Product range overview D series service units, metal design TypeSizeBowl guardCondensate drainPressure indicationActuator lock Supply voltageOptionsè Page/InternetM e t a l b o w l g u a r dP l a s t i c b o w lM a n u a l r o t a r yS e m i -a u t o m a t i cF u l l y a u t o m a t i cW i t h p r e s s u r e g a u g eW i t h o u t p r e s s u r e g a u g eR o t a r y k n o b w i t h d e t e n tR o t a r y k n o b w i t h i n t e g r a t e d l o c k24 V D C110 V A C 230 V A C D i r e c t l y a c t u a t e d p r e s s u r e r e g u l a t o r w i t h i n t e g r a t e d r e t u r n f l o w f u n c t i o n P i l o t a c t u a t e d p r e s s u r e r e g u l a t o r w i t h i n t e g r a t e d r e t u r n f l o w f u n c t i o nD i f f e r e n t i a l p r e s s u r e i n d i c a t o r Service units FRC/FRCSMicro –n n n –n n n –––––––frc Mini n –n –n n n n n ––––––Midi n –n –n n n n n ––––––Maxin –n –n n n n n –––n n–Service unit combinations FRC-K Micro–frc Mini n –n –n n –n –n –––––Midi n –n –n n –n –n –––––Maxin –n –n n –n –n ––n n –LFR-K LFRS-K Micro –lfr Minin –n –n n –n n n –––––Midi n –n –n n –n n n –––––Maxi n–n–nn–nnn––nn–Individual devices Filter regulators LFR/LFRS Micro –n n n –n n n –––––––lfr Mini n –n –n n n n n ––––––Midin –n –n n n n n ––––––Maxi n –n –n n n n n –––n n –Filters LFMicro –n n n –––––––––––lf Mini n –n –n ––––––––––Midi n –n –n ––––––––––Maxin –n –n ––––––––––Fine and micro filters LFMA/LFMB Micro –lfma, lfmbMini n –n –n –––––––––n Midin –n –n –––––––––n Maxin –n –n –––––––––nActive carbon filters LFX Micro –lfx Mini n ––––––––––––––Midin ––––––––––––––Maxin ––––––––––––––Filter combinations LFMBA Micro –lfmba Mini n –n –n –––––––––n Midin –n –n –––––––––n Maxi n –n –n –––––––––n Pressure regulators LR/LRSMicro –––––n n n –––––––lr Mini –––––n n n n –––n ––Midi –––––n n n n –––n ––Maxi–––––nnnn–––nn–Product range overview D series service units, metal design4è Internet: /catalog/...Subject to change – 2015/032015/03 – Subject to change 5è Internet: /catalog/...Product range overview D series service units, metal design TypeSizeBowl guardPressure indicationActuator lockSupply voltageOptionsè Page/InternetM e t a l b o w l g u a r dP l a s t i c b o w lW i t h p r e s s u r e g a u g eW i t h o u t p r e s s u r e g a u g eR o t a r y k n o b w i t h d e t e n tR o t a r y k n o b w i t h i n t e g r a t e d l o c k24 V D C110 V A C230 V A C N o n -r e t u r n f u n c t i o nP r e s s u r e s w i t c hIndividual devices Pressure regulators LRB/LRBS Micro –lrb Mini –––n n n –––––Midi–––n n n –––––Maxi––Pressure regulator combinations LRB-K Micro –lrb Mini –––n n ––––––Midi –––n n ––––––Maxi ––Lubricators LOEMicro –n –n –––––––loe Mini n ––n –––––––Midi n ––n –––––––Maxi n ––n –––––––On-off valves HEMicro –he Mini –––n n ––––––Midi –––n n ––––––Maxi –––n n ––––––On-off valves,electrical HEE Micro –hee Mini –––n ––n n n ––Midi –––n ––n n n ––Maxi –––n ––n n n ––On-off valves,pneumatic HEP Micro –hep Mini –––n –––––––Midi –––n –––––––Maxi –––n –––––––Soft-start valves HELMicro –hel Mini –––n –––––––Midi –––n –––––––Maxi –––n–––––––Membrane air dryers LDM1Micro –6Mini –Midi –Maxi n ––n –––––––Branching modules FRM Micro –frm Mini –––n –––––n n Midi –––n –––––n n Maxi –––n –––––n n Distributor block FRZMicro –––n –––––––frzMini –––n –––––––Midi –––n –––––––Maxi–––n –––––––Subject to change – 2015/036è Internet: /catalog/...Peripherals overview and Type codes MaxiIndividual unit with connection platesIndividual unit without connection plates, for service unit combinationMounting attachments and accessoriesIndividual unit Combination è Page/Internet with connection plateswithout connection plateswith connection plateswithout connection plates1Mounting bracket HFOEn –n –hfoe-d 2Threaded pin (included in scope of delivery)FRB––nnfrb-dType codesLDM1—½—D—MAXI—300Basic function LDM1Membrane air dryerPneumatic connection –Without connection plates½Connecting plates with connecting thread G ½¾Connecting plates with connecting thread G ¾1Connecting plates with connecting thread G1Series D SeriesSize MAXIGrid dimension 66 mm (without connection plates)Standard flow rate at output q n Off 300300 l/min 600600 l/min 10001,000 l/min2015/03 – Subject to change 7è Internet: /catalog/...Technical dataFunction-M-Flow rate300 … 1,000 l/min -Q-Temperature range +2 … +50 °C -L-Operating pressure 3 … 12.5 barPressure dew point reduction:LDM1-…-300/600: 20 KLDM1-…-1000: 17 KOptimum final dryer with excellent operational reliabilitySuitable for use as an individual device or for integration in existing service unit combinations Flow rate-dependent dew point reductionWear-free function requiring no external energyThe composition of the compressed air remains almost unchanged due to the drying process15% purge air flow rate with the LDM1-…-300/600 and 20% with the LDM1-…-1000Typical areas of application:Drying, cleaning of precision parts Measuring technologyRinsing of precision glass scales Painting systemsPaper and packaging machines-H-NotePrefiltration of the compressed air using a micro filter LFMA-D-MAXI,grade of filtration 0.01 μm (residual particles < 0.1 μm, residual oil content < 0.1 mg/m 3) is vital for flawless functioning of the unit.General technical data SizeMaxiPneumatic connection 1, 2G ½G ¾G1–1)DesignMembrane dryer with internal air consumption Type of mounting Via accessories In-line installation Assembly positionVertical ±5°1)Without connection plates-H-Note: This product conforms to ISO 1179-1 and to ISO 228-1Standard flow rate qn [l/min]TypeLDM1-…-3001)LDM1-…-6001)LDM1-…-10002)Input q n In 3537061,250 Output q n Out 3006001,000 Purge air q n Purge52.9105.92501)Measured at p 1 = 6.9 bar, ýpd In = 25 °C, ýpd Out = 5 °C ± 1.5 °C (ýpA Out = –21.5 °C ± 1.2 °C), ýamb = 25 °C 2)Measured at p 1 = 6.9 bar, ýpd In = 25 °C, ýpd Out = 8 °C ± 1.5 °C (ýpA Out = –19.1 °C ± 1.2 °C), ýamb = 25 °COperating and environmental conditions Type LDM1-…-300LDM1-…-600LDM1-…-1000Operating pressure [bar] 3 … 12,5Operating mediumCompressed air in accordance with ISO 85731:2010 [1:3:1]Pressure dew point reduction [K]202017Ambient temperature [°C]+2 … +50Temperature of medium [°C]+2 … +50Storage temperature [°C]–20 … +60Corrosion resistance class CRC1)21)Corrosion resistance class CRC 2 to Festo standard FN 940070Moderate corrosion stress. Indoor applications in which condensation may occur. External visible parts with primarily decorative requirements for the surface and which are in direct contact with the ambient atmosphere typical for industrial applications.Technical dataWeights [g]Port Without connection plates Connecting plates with connecting threadG½G¾G1LDM1-…-3001,6501,8001,9002,000LDM1-…-6002,1002,2502,3502,450LDM1-…-10002,1002,2502,3502,450MaterialsSectional view1Housing Die-cast zinc2Bowl Wrought aluminium alloy–Seals NBR8è Internet: /catalog/...Subject to change – 2015/032015/03 – Subject to change 9è Internet: /catalog/...Technical dataPressure dew point t pd (output) as a function of the standard flow rate at output q n 1)LDM1-…-300LDM1-…-600t p d [°C ]qn [l/min]t p d [°C ]qn [l/min]LDM1-…-1000qn [l/min]t p d [°C ]1) Measured at pressure dew point t pd (supply) = 25 °C.Example LDM1-…-1000 with 10 bar supply pressure:the pressure dew point reduction at a nominal flow rate of q n = 1,200 l/min is 25 K.Differential pressure Δp as a function of the standard flow rate at output qn LDM1-…-300LDM1-…-600qn [l/min]Δp [m b a r ]qn [l/min]Δp [m b a r ]LDM1-…-1000Δp [m b a r ]qn [l/min]Technical dataType B1B2B3B4B5D1D2D3H1H2L1L2T1T2LDM1-½-D-MAXI-30096806646–G½–M532223292968–LDM1-½-D-MAXI-600519486 LDM1-½-D-MAXI-1000519486LDM1-¾-D-MAXI-30096806646–G¾–M536223292968–LDM1-¾-D-MAXI-600519486 LDM1-¾-D-MAXI-1000519486LDM1-1-D-MAXI-300116916646–G1–M541223292968–LDM1-1-D-MAXI-600519486 LDM1-1-D-MAXI-1000519486LDM1-D-MAXI-300––66467–30M5––329296–11LDM1-D-MAXI-600519486LDM1-D-MAXI-1000519486-H-Note: This product conforms to ISO 1179-1 and to ISO 228-1Ordering dataSize Connection LDM1-…-300LDM1-…-600LDM1-…-1000Part No.Type Part No.Type Part No.TypeWithout connecting platesMaxi–543664LDM1-D-MAXI-300543665LDM1-D-MAXI-600543666LDM1-D-MAXI-1000Connecting plates with connecting threadMaxi G½543667LDM1-½-D-MAXI-300543668LDM1-½-D-MAXI-600543669LDM1-½-D-MAXI-1000 G¾543670LDM1-¾-D-MAXI-300543671LDM1-¾-D-MAXI-600543672LDM1-¾-D-MAXI-1000G1543673LDM1-1-D-MAXI-300543674LDM1-1-D-MAXI-600543675LDM1-1-D-MAXI-1000Subject to change – 2015/03 10è Internet: /catalog/...Festo - Your Partner in AutomationConnect with us/socialmedia 1Festo Inc.2Festo Pneumatic 3Festo Corporation 4Regional Service Center 5300 Explorer DriveMississauga, ON L4W 5G4CanadaAv. Ceylán 3,Col. Tequesquináhuac 54020 Tlalnepantla, Estado de México1377 Motor Parkway Suite 310Islandia, NY 117497777 Columbia Road Mason, OH 45040Festo Customer Interaction CenterTel:187****3786Fax:187****3786Email:*****************************Multinational Contact Center 01 800 337 8669***********************Festo Customer Interaction Center180****3786180****3786*****************************S u b j e c t t o c h a n g e。