ABB ACS800风电变流器硬件手册
- 格式:pdf
- 大小:5.56 MB
- 文档页数:128
ABB ArrayA C S教00ACS800培训教程一 ACS800的硬件部分二 ACS800的操作面板说明三 ACS800参数四 Drive Window调试软件ACS800培训教程一 ACS800的硬件部分主电路和控制ACS800培训教程一 ACS800的硬件部分主电路和控制下表简要介绍了主回路的配置ACS800培训教程一 ACS800的硬件部分主电路和控制下图显示了传动单元的控制接口ACS800培训教程一 ACS800的硬件部分印刷电路板传动单元包括下列标准印刷电路板:•主电路板(RINT) ;•电机控制和I/O 控制板(RMIO) ;•当选用EMC 设备时,有一EMC 滤波器板(RRFC) ,否则为压敏电阻板(RVAR) ;•控制盘(CDP 312R) ;•外形规格R6 中的铜排板(RBUB)ACS800培训教程一 ACS800的硬件部分电机控制电机控制模式可选择为直接转矩控制(DTC) 或选择为标量控制。
ACS800培训教程一 ACS800的硬件部分RMIO 板上的可选模块可选模块1:RMBA: MODBUS 总线协议适配器模块RAIO: 扩展模拟I/O 模块RDIO: 扩展数字I/O 模块RLON: LONWORKS 总线协议适配器模块RIBA: INTERBUS-S 总线协议适配器模块RPBA: PROFIBUS-DP 总线协议适配器模块RCAN: CANOPEN 总线协议适配器模块RCNA: CONTROLNET 总线协议适配器模块RMBP: MODBUSPLUS 总线协议适配器模块RETA: ETHTRNET 总线协议适配器模块RTAC: 模拟测速机接口模块ACS800培训教程一 ACS800的硬件部分RMIO 板上的可选模块可选模块2:RTAC: 模拟测速机接口模块RAIO: 扩展模拟I/O 模块RDIO: 扩展数字I/O 模块可选模块3:RDCO-01: DDCS 光纤接口模块(10MHz)RDCO-02: DDCS 光纤接口模块(10/5MHz)RDCO-03: DDCS 光纤接口模块(5MHz)ACS800培训教程一 ACS800的硬件部分主回路接线图ACS800培训教程一 ACS800的硬件部分主回路实际接线图ACS800培训教程一 ACS800的硬件部分I/O 和现场总线模块的电缆ACS800培训教程一 ACS800的硬件部分脉冲编码器模块电缆ACS800培训教程一 ACS800的硬件部分RMIO 板上的外部控制电缆接线ACS800培训教程一 ACS800的硬件部分RMIO 板上的外部控制电缆接线ACS800培训教程一 ACS800的硬件部分RMIO 板上的外部控制电缆接线ACS800培训教程一 ACS800的硬件部分RMIO 板上的外部控制电缆接线ACS800培训教程一 ACS800的硬件部分RMIO 电路板规格模拟输入ACS800培训教程一 ACS800的硬件部分RMIO 电路板规格恒定电压输出ACS800培训教程一 ACS800的硬件部分RMIO 电路板规格辅助电压输出ACS800培训教程一 ACS800的硬件部分RMIO 电路板规格模拟输出ACS800培训教程一 ACS800的硬件部分RMIO 电路板规格数字输入ACS800培训教程一 ACS800的硬件部分RMIO 电路板规格继电器输出ACS800培训教程一 ACS800的硬件部分在启动ACS 800 之前应检查其机械和电气安装。
ABBACS800设置详细摘要:一、变频器的简朴本地启动1。
首先确定空开闭合,接触器得电;2(按LOC/REM使变频器为本地控制模式3。
按FAR进入控制盘的参数设置模式用双箭头键选到99参数组,然后用单箭头键选择04,ENTER进入99.04 电机传动。
一、变频器的简朴本地启动1. 首先确定空开闭合,接触器得电;2(按LOC/REM使变频器为本地控制模式3。
按FAR进入控制盘的参数设置模式用双箭头键选到99参数组,然后用单箭头键选择04,ENTER进入99.04 电机传动模式 (DTC)DTC 变频器设定值为转速(多数情况下用这种模式)SCALA 变频器的设定值为频率选择好模式后按ENTER确认 (取消按ACT返回)4. 按ACT回到当前状态5。
按REF,选择上下调节键,输入指定的参数后,按ENTER确认6. 按启动键,变频器启动至此,完成了一个变频器简单的本地运行过程假如需要将已显示的实际信号替换显示成其他的实际信号,可以按以下步骤进行操作: 1。
按ACT进入实际信号显示模式;2. 选择需要改变的参数行,按ENTER进入;3。
按单双箭头键,选择要显示的参数或改变参数组;(常用的几个显示信号:01。
02 电机的实际转速 SPEED01。
03 传动输入频率的实际值 FREQ03.20 变频器最后一次故障的代码 LAST FLT)4. 按ENTER确认并返回实际信号显示模式; (取消直接按ACT)二、上传和下载如何将已经设置好电机需要上传到CDP—312操作面板上:全国免费服务热线咨询:40088181601。
激活可选设备的通讯确认98。
02 COMM。
MODULE LINK设定为FIELDBUS98。
07 COMM PROFILE 设定为ABB DRIVES2. 按LOC/REM切换到L本地控制状态;3. 按FUNC进入功能模式;4. 按单双箭头键进入UPLOAD功能按ENTER执行上传,完成后自动切换到当前信号显示模式;、5. 如果要将控制盘从一个传动单元移开前,确认控制盘处于远程控制模式状态(可以按LOC/REM进行改变)如何将数据从控制盘下载到传动单元:1。
ACS800变频器快速调试手册目录一、变频器概述二、变频器送电前检查三、变频器面板介绍四、变频器程序功能五、变频器应用宏程序六、变频器实际信号值七、变频器设置参数八、变频器故障排除九、变频器故障跟踪一、变频器概述ACS800 –04P是新一代全数字交流变频器,能达到控制交流电机的完美极限。
ACS800是第一代采用风机专用特性的软件和IGBT半导体技术的交流变频器,它能够在没有光码盘或测速电机的反馈的条件下,精确控制任何标准鼠笼电机的速度和转矩。
ACS800的具有如下优越性能:电源断电时的运行—ACS800将利用正在旋转着的电机的动能继续运行,只要电机旋转并产生能量,ACS800将继续运行。
*零速满转矩—由ACS800带动的电机能够获得在零速时电机的额定转矩,并且不需要光码盘或测速电机的反馈。
而矢量控制变频器只能在接近零速时实现满力矩输出。
*起动转矩—DTC提供的精确的转矩控制使得ACS800能够提供可控且平稳的最大起动转矩。
最大起动转矩能达到200%的电机额定转矩。
*自动起动—ACS800的自动起动特性超过一般变频器的飞升起动和积分起动的性能。
因为ACS800能在几毫秒内测出电机的状态,任何的条件下在0.48s 内迅速起动。
而矢量控制变频器则需大于是2.2s。
*磁通优化—在优化模式下,电机磁通被自动地适应于负载以提高效率,同时降低电机的噪音。
得益于磁通优化,基于不同的负载,变频器和电机的总效率可提高1%~10%。
*磁通制动—ACS800能通过提高电机的磁场来提供足够快的减速。
ACS800持续监视电机的状态,在磁通制动时也不停止监视。
磁通制动也能用于停止电机和从一个转速变换到另一个转速。
而其他品牌的变频器所使用的直流制动是不可能实现此功能的。
*精确速度控制—ACS800的动态转速误差在开环应用时为0.3%s,在闭环应用时为0.1%s。
而矢量控制变频器在开环时大于0.8%s,闭环时为0.3%s。
ACS800变频器的静态精度为0.01%。
New ACS 800 for ABB Electromagnetic Stirrer for Ladle Furnaces means good savings for Ovako Bar Oy AbABB’s electromagnetic stirrer for its ladle furnace,LF-EMS, was installed at Ovako Bar Oy Ab in Imatra in southeast Finland in 1988. Production was smooth until 2005 when the old YOQD drive for the stirrer came tothe end of its life cycle with three unexpected failures. The old YOQD frequency converter needed to be replaced with ABB’s modern ACS 800 drive due to life cycle considerations.SummaryThe old drive seemed to be at the end of its life cycle simply because it is difficult to get necessary spare parts. What is more, it would no longer be economical to keep it in use since the old YOQD was an analogue drive, which means adjust-ments are difficult to make.“The main reason for this investment was to keep production without any interruption because all production in Ovako Imatra goes through this stirrer. All failures in the old drives would reduce or stop production if the stirrer was not in operation”, says Jukka Kyllönen, manager of electrical maintenance at Ovako Imatra.ABB’s deliveryDismounting the old drive and installing the new ACS 800 posed a great challenge. The transport route for the new equipment to the electrical room was narrow and long,and height was limited. As a result, the new drive had to be transported in parts. The new ACS 800 was commissioned in 2006. Thanks toa good relationship and good cooperation between ABB and Ovako Imatra, the overall installation went very successfully and start-up was on schedule.Benefits“This case shows that Ovako Imatra does not need to buy new stirrer. Replacing the old drive with a modern one for the existing stirrer means good savings for us”, says Jukka Kyllönen.Space savings and easy access to spare parts are two main advantages from a maintenance point of view according to Ari Hirvonen, electrical maintenance engineer at Ovako Imatra.“Since the start-up of the ACS 800 drive, no breakdowns have been recorded”, concludes Ari Hirvonen.CooperationThe project was jointly executed by ABB Center of Excellence in Sweden and ABB Service in Finland. The seamless cooperation within ABB paved the way for the extremely good cooperation between ABB and Ovako Imatra.“We are very satisfied with the good cooperation between Ovako Imatra and ABB on this project, and we expect the same for the entire life cycle of the equipment”, says JukkaKyllönen.“Replacing the old drive with a modern one for the existing stirrer means good savings for us”, says Jukka Kyllönen, manager of electrical maintenance at Ovako Imatra, Finland.For more information please contact: ABB ABMetallurgy ProductsTerminalvägen 24SE-721 59 Västerås, Sweden Phone: +46 21 32 50 00Fax: +46 21 14 83 27E-mail: **********************.com/metals CustomerOvako produces long specialty steel products, with afocus on demanding product segments. About 1 million tonnes of low alloy steels and carbon steels are suppliedin the form of bars, tubes and rings every year to the automotive and transport equipment and general engineering industries, mainly in the Nordic countriesand Europe.Ovako Bar Oy Ab is located in Imatra in southeastFinland, a mere 7 km from the Russian border. OvakoBar Oy Ab is included in the Ovako Bar Division that comprises 50% of the company’s total sales.©Copyright21ABB.Allrightsreserved.Specificationssubjecttochangewithoutnotice./3BSE6394/EllensByrålåda21.11。
ABB-ACS800系列变频器快速调试手册ACS800变频器目录共40页,第1页一、变频器概述二、变频器送电前检查三、变频器面板介绍四、变频器程序功能五、变频器应用宏程序六、变频器实际信号值七、变频器设置参数八、变频器故障排除九、变频器故障跟踪一、变频器概述ACS800–04P是新一代全数字交流变频器,能达到控制交流电机的完美极限。
ACS800是第一代采用风机专用特性的软件和IGBT半导体技术的交流变频器,它能够在没有光码盘或测速电机的反馈的条件下,精确控制任何标准鼠笼电机的速度和转矩。
ACS800的具有如下优越性能:电源断电时的运行—ACS800将利用正在旋转着的电机的动能继续运行,只要电机旋转并产生能量,ACS800将继续运行。
共40页,第2页零速满转矩—由ACS800带动的电机能够获得在零速时电机的额定转矩,并且不需要光码盘或测速电机的反馈。
而矢量控制变频器只能在接近零速时实现满力矩输出。
起动转矩—DTC提供的精确的转矩控制使得ACS800能够提供可控且平稳的最大起动转矩。
最大起动转矩能达到200%的电机额定转矩。
自动起动—ACS800的自动起动特性超过一般变频器的飞升起动和积分起动的性能。
因为ACS800能在几毫秒内测出电机的状态,任何的条件下在0.48内迅速起动。
而矢量控制变频器则需大于是2.2。
磁通优化—在优化模式下,电机磁通被自动地适应于负载以提高效率,同时降低电机的噪音。
得益于磁通优化,基于不同的负载,变频器和电机的总效率可提高1%~10%。
磁通制动—ACS800能通过提高电机的磁场来提供足够快的减速。
ACS800持续监视电机的状态,在磁通制动时也不停止监视。
磁通制动也能用于停止电机和从一个转速变换到另一个转速。
而其他品牌的变频器所使用的直流制动是不可能实现此功能的。
精确速度控制—ACS800的动态转速误差在开环应用时为0.3%,在闭环应用时为0.1%。
而矢量控制变频器在开环时大于0.8%,闭环时为0.3%。
ACS800变频器快速调试手册目录一、变频器概述二、变频器送电前检查三、变频器面板介绍四、变频器程序功能五、变频器应用宏程序六、变频器实际信号值七、变频器设置参数八、变频器故障排除九、变频器故障跟踪一、变频器概述ACS800 –04P是新一代全数字交流变频器,能达到控制交流电机的完美极限。
ACS800是第一代采用风机专用特性的软件和IGBT半导体技术的交流变频器,它能够在没有光码盘或测速电机的反馈的条件下,精确控制任何标准鼠笼电机的速度和转矩。
ACS800的具有如下优越性能:电源断电时的运行—ACS800将利用正在旋转着的电机的动能继续运行,只要电机旋转并产生能量,ACS800将继续运行。
*零速满转矩—由ACS800带动的电机能够获得在零速时电机的额定转矩,并且不需要光码盘或测速电机的反馈。
而矢量控制变频器只能在接近零速时实现满力矩输出。
*起动转矩—DTC提供的精确的转矩控制使得ACS800能够提供可控且平稳的最大起动转矩。
最大起动转矩能达到200%的电机额定转矩。
*自动起动—ACS800的自动起动特性超过一般变频器的飞升起动和积分起动的性能。
因为ACS800能在几毫秒内测出电机的状态,任何的条件下在0.48s 内迅速起动。
而矢量控制变频器则需大于是2.2s。
*磁通优化—在优化模式下,电机磁通被自动地适应于负载以提高效率,同时降低电机的噪音。
得益于磁通优化,基于不同的负载,变频器和电机的总效率可提高1%~10%。
*磁通制动—ACS800能通过提高电机的磁场来提供足够快的减速。
ACS800持续监视电机的状态,在磁通制动时也不停止监视。
磁通制动也能用于停止电机和从一个转速变换到另一个转速。
而其他品牌的变频器所使用的直流制动是不可能实现此功能的。
*精确速度控制—ACS800的动态转速误差在开环应用时为0.3%s,在闭环应用时为0.1%s。
而矢量控制变频器在开环时大于0.8%s,闭环时为0.3%s。
ACS800变频器的静态精度为0.01%。
ACS 800硬件手册ACS 800-02/U245 ~ 560 kW (60 ~ 600 HP)ACS800 单传动手册总手册ACS 800-01/U1 硬件手册1.1 ~110 kW (1.5 ~ 150 HP) 3ABD00009805 Based on:3AFE 64382101*安全须知*电气安装设计*机械和电气安装*电机控制和I/O板(RMIO)*维护*技术数据*尺寸图*制动电阻器ACS 800-02/U2 硬件手册90 ~500 kW (125 ~ 600 HP) 3ABD00009806 Based on:3AFE 64567373*安全须知*电气安装设计*机械和电气安装*电机控制和I/O板(RMIO)*维护*技术数据*尺寸图*制动电阻器传动应用程序固件手册 (相关手册随机托运)标准版3ABD00009803 Based on:3AFE 64527592*控制盘的使用*带外部控制连接图的标准应用宏*标准应用程序的参数*故障跟踪*现场总线控制自定义编程应用指南 3ABD00009804Based on:3AFE64527274*自定义编程介绍*如何编写程序*如何记录程序可选手册 (与所选设备随机托运)现场总线适配器、I/O 扩展模块等*安装*编程*故障跟踪*技术数据ACS 800-02/U2 传动单元45 ~ 560 kW60 ~ 600 HP硬件手册3ABD00009806 版本APDM: 30005500BASED ON: 3AFE 64567373 REV A EN生效日期:2005年11月8日2005 ABB 北京电气传动系统有限公司版权所有5安全须知本章内容本章包括在安装、运行和维修传动单元时必须遵守的安全规范。
如果忽视,将造成人身伤害甚至死亡,或损坏变频器、电机或其它传动设备。
在操作传动单元之前,请仔细阅读本章内容。
本章适用的产品本章适用 ACS800-01/U1, ACS800-02/U2 和 ACS800-04/U4。