R&S ES-SCAN Test Report Rohde & Schwarz

2014年2月25日 1 EMI Measurement Test Report

EMI Measurement Test Report

Device Under Test Project No. Model No.: S/N: Input: Output: Test line: Ambient: Test standard: Remark: Pre-measurement Graph

100 kHz1 MHz10 MHz9 kHz30 MHz 20.0 30.0 40.0 50.0 60.0 70.0 80.0 90.0100.0110.0

10.0120.0dBµV

Limits55015MQP55015MAV

TransducerENV216TracesPK+AV

Final Measurement Results Trace Frequency Level Limit Delta LimitDelta Ref Comment (MHz) (dBµV) (dBµV) (dB) (dB)

1 QP 0.00964 62.44 110.00 -47.56 N / off 1 QP 0.06396 78.33 87.76 -9.43 N / off 2 CA 0.506 36.65 46.00 -9.35 N / off 1 QP 0.518 41.65 56.00 -14.35 N / off 2 CA 0.702 36.18 46.00 -9.82 N / off 1 QP 1.526 44.99 56.00 -11.01 N / off 2 CA 7.534 45.79 50.00 -4.21 N / off 1 QP 7.746 53.98 60.00 -6.02 N / off 2 CA 8.03 46.21 50.00 -3.79 N / off 1 QP 8.15 53.93 60.00 -6.07 N / off * = limit exceeded