ACP P2 LED Lamps/SMD---InGaN and GaN (Blue, Cyan, Green) Test and Results

Type Test Applicable Standards Test Condition Note Number of Damaged

Environmental Sequence

Temperature Cycle JEITA ED-4701 100 105 –40℃~25℃~100℃~25℃ 30mins,5mins,30mins,5mins 200 cycles 0/20 Thermal Shock* MIL-STD-202G –40℃~100℃ 30mins,30mins 200 cycles 0/20 Moisture-Resistance Cycle JEITA ED-4701 200 203 25℃~65℃~–10℃ 90%RH 24H/cycle 10 cycles 0/20

High-Temperature Stotage

JEITA

ED-4701 200 201 TA=100℃ 1000H 0/20

Humidity Heat Storage JEITA ED-4701 100 103 TA=60℃ RH=90% 1000H 0/20 Low-Temperature Storage*

JEITA

ED-4701 200 202 TA=–40℃ 1000H 0/20

Operation Sequence Life Test* – TA=25℃ Oval: IF=35mA(GB) 1000H 0/20 IF=50mA(R) Round: IF=30mA(GB) IF=50mA® High Humidity Heat Life Test* – 60℃ RH=90% IF=20mA 500H 0/20

Low Temperature Life Test – TA=–30℃ IF=20mA 1000H 0/20

Destructive Sequence

Resistance to Soldering Heat JEITA ED-4701 300 302 TSOL=260(+/-5)℃,10sec (3mm from the base of the epoxy bulb)

3 time 0/20

Solderability JEITA ED-4701 300 303 TSOL=235(+/-5)℃,5sec (using flux) 3 time (over 95%) 0/20 Lead Bend Test JEITA ED-4701 400 401 Load 5N (0.5kgf) 0°~ 90°~ 0° bend 2 times No notice- able damage 0/20

Lead Pull Test JEITA ED-4701 400 401 Load 10N (1kgf) 10(+/-1)sec No notice- able damage 0/20 ESD Electrostatic Discharge Test AEC (Q101-001) Human body model 1000V (Forward and Reverse current conduct electricity,each 1 time) 0/10 Items marked with * are selective. Failure Criteria Item Symbol Test Condition Criteria for Judgment

Min Max Forward Voltage VF IF

=20mA – Initial Data x 1.1

Reverse Current IR VR

=5V – 1uA

Luminous Flux/ Intensity /IV IF=20mA Initial Data x 0.7(Total degradation) Initial Data x 0.5(Single lamp degradation) – LED信赖性测试标准——P4 LED(RY) (2011-08-16 21:15:24) 转载▼ 标签: 杂谈 分类: LED

ACP P4 LED Lamps---AlInGaP(Red, Amber) Test and Results

Type Test Applicable Standards Test Condition Note Number of Damaged

Environmental Sequence

Temperature Cycle JEITA ED-4701 100 105 –40℃~25℃~100℃~25℃ 30mins,5mins,30mins,5mins 200 cycles 0/20 Thermal Shock* MIL-STD-202G –40℃~100℃ 30mins,30mins 200 cycles 0/20 Moisture-Resistance Cycle JEITA ED-4701 200 203 25℃~65℃~–10℃ 90%RH 24H/cycle 10 cycles 0/20

High-Temperature Stotage

JEITA

ED-4701 200 201 TA=100℃ 1000H 0/20

Humidity Heat Storage JEITA ED-4701 100 103 TA=60℃ RH=90% 1000H 0/20 Low-Temperature Storage*

JEITA

ED-4701 200 202 TA=–40℃ 1000H 0/20

Operation Sequence Life Test* – TA=25℃ IF=35mA 1000H 0/20 High Humidity Heat Life Test* – 60℃ RH=90% IF=20mA 500H 0/20

Low Temperature Life Test – TA=–30℃ IF=30mA 1000H 0/20

Destructive Sequence Resistance to Soldering Heat JEITA ED-4701 TSOL=260(+/-5)℃,10sec 3 time 0/20 300 302 (3mm from the base of the epoxy bulb)

Solderability JEITA ED-4701 300 303 TSOL=235(+/-5)℃,5sec (using flux) 3 time (over 95%) 0/20

Lead Bend Test JEITA ED-4701 400 401 Load 5N (0.5kgf) 0°~ 90°~ 0° bend 2 times No notice- able damage 0/20

Lead Pull Test JEITA ED-4701 400 401 Load 10N (1kgf) 10(+/-1)sec No notice- able damage 0/20 ESD Electrostatic Discharge Test AEC (Q101-001) Human body model 1000V (Forward and Reverse current conduct electricity,each 1 time) 0/10 Items marked with * are selective. Failure Criteria Item Symbol Test Condition Criteria for Judgment

Min Max Forward Voltage VF IF

=70mA – Initial Data x 1.1

Reverse Current IR VR

=5V – 1uA

Luminous Flux/ Intensity /IV IF=70mA Initial Data x 0.65(Total degradation) Initial Data x 0.5(Single lamp degradation) – LED信赖性测试标准——P4 LED(RY) (2011-08-16 21:15:24) 转载▼ 标签: 杂谈 分类: LED

ACP P4 LED Lamps---AlInGaP(Red, Amber) Test and Results

Type Test Applicable Standards Test Condition Note Number of Damaged

Environmental Sequence

Temperature Cycle JEITA ED-4701 100 105 –40℃~25℃~100℃~25℃ 30mins,5mins,30mins,5mins 200 cycles 0/20 Thermal Shock* MIL-STD-202G –40℃~100℃ 30mins,30mins 200 cycles 0/20 Moisture-Resistance Cycle JEITA ED-4701 200 203 25℃~65℃~–10℃ 90%RH 24H/cycle 10 cycles 0/20

High-Temperature Stotage

JEITA

ED-4701 200 201 TA=100℃ 1000H 0/20

Humidity Heat Storage JEITA ED-4701 100 103 TA=60℃ RH=90% 1000H 0/20 Low-Temperature Storage*

JEITA

ED-4701 200 202 TA=–40℃ 1000H 0/20

Operation Sequence Life Test* – TA=25℃ IF=35mA 1000H 0/20 High Humidity Heat Life Test* – 60℃ RH=90% IF=20mA 500H 0/20

Low Temperature Life Test – TA=–30℃ IF=30mA 1000H 0/20

Destructive Sequence Resistance to Soldering Heat JEITA ED-4701 TSOL=260(+/-5)℃,10sec 3 time 0/20