功能障碍低频脉冲电刺激仪ES-420
- 格式:ppt
- 大小:3.84 MB
- 文档页数:46
低频脉冲电刺激治疗脑梗死后语言功能障碍的临床效果【摘要】目的分析低频脉冲电刺激治疗脑梗死后语言功能障碍的应用效果。
方法本次研究对象为本院72例脑梗死后语言功能障碍患者,收治时间2020年11月-2021年11月,随机将其均分为对照组36例,行常规语言功能训练,实验组36例,联合低频脉冲电刺激治疗,比较两组临床疗效。
结果实验组的自发言语等级、执行命令、短句理解和听名指物评分均明显优于对照组(P<0.05)。
结论给予脑梗死后语言功能障碍患者低频脉冲电刺激治疗能够显著改善患者语言功能,具有推广价值。
【关键词】低频脉冲电刺激;脑梗死;语言功能障碍[Abstract] Objective To analyze the application effect of low-frequency pulse electrical stimulation in the treatment of language dysfunction after cerebral infarction. Methods 72 patients with language dysfunction after cerebral infarction in our hospital were randomly pided into 36 cases in the control group and 36 cases in the experimental group. They were treated with low-frequency pulse electrical stimulation from November 2020 to November 2021 The clinical efficacy of the two groups. Results the scores of spontaneous speech level, executive command, short sentence understanding and listening to name and finger in the experimental group were significantly better than those in the control group (P < 0.05). Conclusion low frequency pulse electrical stimulation can significantly improve the language function of patients with language dysfunction after cerebral infarction.[Key words] low frequency pulse electrical stimulation; cerebral infarction; language dysfunction脑梗死是临床多发心脑血管疾病之一,发病血管相对供应区域受到损伤,根据发病部位不同,患者出现的临床表现也具有一定差异,常见症状有语言功能障碍、认知功能障碍以及肢体运动功能障碍等【1】。
新型低频电脉冲理疗仪的研制
胡鸿志
【期刊名称】《电子测量技术》
【年(卷),期】2011(34)7
【摘要】低频电脉冲理疗仪是家庭医疗保健的常用仪器。
介绍了1种基于经皮神经电刺激疗法的新型低频电脉冲理疗仪,利用AVR单片机的脉宽调制(PWM)功能,通过信号调理和功率放大,调节输出电极的电脉冲参数和药包温度,引进经典的PD 控制算法改善了温度的输出特性。
该低频电脉冲理疗仪具有智能控制、操作方便、成本低廉;实验和试用结果表明,理疗仪工作稳定可靠,电脉冲幅度和频率可在规定范围内任意调节,对缓解疲劳和减轻疼痛有明显功效。
【总页数】4页(P5-7)
【关键词】理疗仪;低频;单片机;PWM
【作者】胡鸿志
【作者单位】桂林电子科技大学电子工程与自动化学院
【正文语种】中文
【中图分类】TP29
【相关文献】
1.面向术前焦虑症的低频理疗仪研制 [J], 程希为;倪奕;徐远;程晓;房银芳;武帅;匡绍龙
2.一种基于新型单片机的智能理疗仪的研制 [J], 王松;赵辉;褚文胜
3.中药熏蒸联合电脉冲式理疗仪治疗骨关节炎50例 [J], 阎巍巍;贾路;魏玲玲
4.基于TENS低频电脉冲的女性疲劳缓解压力袜研制 [J], 吴海燕;李艳梅
5.基于TENS低频电脉冲的女性疲劳缓解压力袜研制 [J], 吴海燕;李艳梅
因版权原因,仅展示原文概要,查看原文内容请购买。
低频电子脉冲治疗仪操作规程1.使用前的准备(1)确保治疗仪所处的环境干燥,温度适宜,并远离水源和易燃物。
(2)检查治疗仪的电源线、传导线和电极片是否完好无损,确保连接正常。
(3)查看治疗仪设备的开关和调节器是否正常,避免出现意外事故。
(4)清洁治疗仪设备和配件,确保无污染和细菌。
2.操作步骤(1)将治疗仪设备放置于平稳的桌面上,并连接电源线到正确的电源插座。
(2)将治疗仪传导线与治疗仪设备连接,确保连接牢固。
(3)将电极片与治疗仪传导线连接,确保电极片与人体接触良好。
(4)清洁和消毒治疗区域(皮肤),以确保无细菌和感染。
(5)将电极片粘贴于治疗区域,尽量贴紧皮肤,并确保电极片之间没有空隙。
(6)打开治疗仪设备的电源开关,并调节电流强度,起初设置较低的强度,逐渐加大。
(7)根据医嘱或个人需要选择适宜的治疗模式和时间,一般为15-30分钟。
(8)在治疗过程中,密切观察患者的反应,如出现不适或异常情况,应立即停止治疗。
(9)治疗结束后,首先关闭治疗仪设备的电源开关,然后将电极片从皮肤上取下,注意不要拉扯皮肤。
(10)将电极片和传导线等配件清洗和消毒,存放在干燥、通风的地方,避免阳光直射。
3.注意事项(1)低频电子脉冲治疗仪只能在医生的指导下使用,不得自行操作。
(2)患者在使用低频电子脉冲治疗仪之前,应了解治疗的目的、原理和可能的风险。
(3)尽量避免在患有心脏病、心脏起搏器和其他电子装置的人群中使用低频电子脉冲治疗仪。
(4)患者在治疗过程中,不宜进行运动、驾驶车辆或操作机器等需要注意安全的活动。
(5)孕妇、儿童或有感染性疾病的人群,应在医生的指导下使用低频电子脉冲治疗仪。
(6)长时间的连续使用低频电子脉冲治疗仪可能导致肌肉疲劳,应避免超过医生建议的治疗时间。
(7)使用低频电子脉冲治疗仪前后,不宜进食大量食物,以避免消化不良和恶心等不适症状。
Advances in Clinical Medicine 临床医学进展, 2023, 13(8), 13597-13602 Published Online August 2023 in Hans. https:///journal/acm https:///10.12677/acm.2023.1381900低频电刺激联合生物反馈治疗PFD 疗效研究陈 敏,刘 静,张吟真第五人民医院妇科,江苏 常熟收稿日期:2023年7月26日;录用日期:2023年8月17日;发布日期:2023年8月24日摘要目的:对盆底功能障碍性疾病(PFD)的患者行非手术治疗临床效果。
电刺激联合生物反馈治疗在盆底功能障碍性疾病中治疗前后的临床价值及疗效。
方法:选取2020-10~2021-10期间,我院治疗的100例盆底功能障碍性疾病(子宫脱垂、阴道前后壁膨出、压力性尿失禁)的非手术治疗患者为主要研究对象。
本文研究的非手术治疗主要指低频脉冲电刺激联合生物反馈治疗,对100例患者治疗及效果进行临床回顾性分析。
分析治疗前及治疗后,比较治疗前后盆底肌纤维电压、耐力收缩值和临床症状。
结果:治疗后盆底肌肉I 类肌、II 类肌肌力,肌电位、临床症状均优于治疗前(P < 0.05)。
结论:盆底功能障碍性疾病(PFD)患者通过低频脉冲电刺激联合生物反馈治疗,子宫脱垂、阴道前后壁膨出、压力性尿失禁患者症状明显改善、肌力提高、肌电位增高,对于轻中度盆底功能障碍性疾病的治疗有效。
关键词低频电刺激,生物反馈,盆底疾病,肌力,肌电位Study on the Efficacy of Low-Frequency Electrical Stimulation Combined with Biofeedback in the Treatment of PFDMin Chen, Jing Liu, Yinzhen ZhangGynecology Department, Fifth People’s Hospital, Changshu JiangsuReceived: Jul. 26th , 2023; accepted: Aug. 17th , 2023; published: Aug. 24th , 2023AbstractObjective: To determine the clinical effect of non-surgical treatment on patients with pelvic floor陈敏等dysfunction;the clinical value and efficacy of electrical stimulation combined with biofeedback in pelvic floor dysfunction before and after treatment. Methods: 100 patients with pelvic floor dys-function diseases (uterine prolapse, anterior and posterior vaginal wall prolapse, stress urinary incontinence) treated in our hospital during 2020-10~2021-10 were selected as the main research object. In this study, the non-surgical treatment mainly refers to low-frequency pulsed electrical stimulation combined with biofeedback therapy. Clinical retrospective analysis was conducted on the treatment and efficacy of 100 patients. The pelvic floor muscle fiber voltage, endurance con-traction value and clinical symptoms were compared before and after treatment. Results: After treatment, the muscle strength, muscle potential and clinical symptoms of pelvic floor muscle class I and II were better than those before treatment (P < 0.05). Conclusion: Patients with pelvic floor dysfunction disease (PFD) can improve symptoms, muscle strength and muscle potential of patients with uterine prolapse, anterior and posterior vaginal wall prolapse and stress urinary incontinence by low-frequency pulse electrical stimulation combined with biofeedback therapy, which is effective in the treatment of mild and moderate pelvic floor dysfunction disease.KeywordsLow-Frequency Electrical Stimulation, Biofeedback, Pelvic Floor Disorders, Muscle Strength,Muscle Potentials Array Copyright © 2023 by author(s) and Hans Publishers Inc.This work is licensed under the Creative Commons Attribution International License (CC BY 4.0)./licenses/by/4.0/1. 引言盆底支持结构包括盆底肌肉、结缔组织(筋膜、韧带)、血管和神经等,形成一个复杂的、相互协调的系统。
综合康复疗法及低频电刺激改善脑卒中吞咽障碍的观察【摘要】目的观察并探讨综合康复疗法及低频电刺激在改善脑卒中吞咽障碍的效果。
方法选取我院2011年1月——2012年6月期间收治的72例脑卒中吞咽障碍患者,均接受吞咽训练和常规的药物治疗,其中41例同时进行低频脉冲电刺激疗法作为观察组,其余31例作为对照组,比较两组患者吞咽功能。
结果观察组患者的总有效率为878%,对照组患者的总有效率为6452%,观察组患者的效果明显优于对照组患者,两组患者比较具有明显差异(p005),具有一定的可比性。
12 方法两组患者均接受吞咽训练和常规的药物治疗,观察组则在此基础上配合低频脉冲电刺激疗法。
121 综合康复治疗(1)唇部、下颌、面颊部、舌及软腭的运动训练:包括颈部放松、口唇闭合训练、舌的各方向运动、颜面及下颌运动等,如抿嘴、撅嘴、伸舌、鼓腮及咀嚼训练,进行舌肌和咀嚼肌的按摩,以促进吞咽及构音器官的血液循环,改善咽部肌肉的灵活性和协调性。
(2)声带闭合、喉上抬练习:屏气-发声训练,可训练声门闭锁功能、强化软腭肌力。
(3)呼吸训练与咳嗽训练:练习腹式呼吸,吹蜡烛或肥皂泡、缩口呼吸练习、咳嗽训练等,以提高咳出能力,防止误咽。
(4)感觉促进综合训练及冷刺激训练:用冰冻棉签或棉签蘸少许冰水轻轻刺激病人的后腭弓、软腭、腭弓、咽后壁及舌后根。
(5)直接摄食训练:①吞咽姿势的改变包括身体和头部姿势的调整,通过两者的改变来改善吞咽障碍。
常用的体位有坐位与半坐卧位头前倾;②食物选择,根据吞咽障碍的程度及部位,本着先易后难的原则来选择;③方法,采用仰头吞咽、低头吞咽、转头吞咽等方法[3]。
④重度吞咽障碍患者应选择使用鼻饲饮食进行合理的营养支持,并加强营养支持护理,减少患者各种并发症的发生。
同时要进行吞咽功能系统康复训练,使患者及早拔出胃管,恢复自主饮食。
(6)空吞咽训练。
吞咽前使用冰棉棒,轻触前、后腭弓、软腭弓、舌后部、咽后壁,使触发吞咽反射的区域变敏感后,再进行空吞咽动作。
上海华谊牌G6805-2B低频电子脉冲治疗仪说明书产品组成:产品由主机,电极组成。
电极分皮肤电极,毫针电极,探穴电极三种,毫针电极夹必须与毫针配用,毫针和皮肤电极必须具有医疗器械注册证。
技术参数:电源电压:直流6V 1#干电池4节或外接电源适配器输出脉冲波形:非对称双向脉冲波输出模式:连续、疏密、断续连续波频率:0.05~101Hz;连续波频率调节:单片机调节连续波频率指示:液晶显示断续疏密调制频率:10~20次/分可调;输出脉冲宽度:0.5ms输出路数:6输出脉冲峰-峰值电压:250Ω负载电阻时大于20V,小于70V;500Ω负载电阻时大于40V,小于140V输出闭锁:任意一路输出强度未置“OFF”启动电源时报警指示灯闪亮,自动切断输出定时范围:0~99分设置定时显示:倒计时液晶显示外形尺寸:长×宽×高 230mm×160mm×75mm附件:毫针电极夹×6 外接电源适配器×1 皮肤电极2套维修和保养:1、电针仪器使用应放置在湿气、灰尘少的地方,应避开日光直射或暖气附近的地方。
2、贮存时应置于通风良好无腐蚀气体、具有防尘防潮的室内。
3、电池电压不足时应及时更换,更换时不要将新旧电池混和使用,应注意正负极性,若两周内不使用,必须取出干电池。
4、仪器外表用湿布擦拭即可,请勿使用酒精、汽油或活期他溶剂。
注意事项:1、毫针电极夹用毕后,用以用酒精消毒。
皮肤电极中的导电贴片胶应为一次性使用或专人使用,使用后应撕去,以免交叉感染。
皮肤电极中的导电电极板、探穴电极用毕后需清洗,再用以用酒精消毒。
对皮肤病患者或急性传染病患者需用专人专用电极,用毕后需作严格的灭菌消毒处理,防止交叉感染。
2、对皮肤破损、溃疡处应避免安装皮肤电极。
不要在心脏两侧或前心后背安置皮肤电极,避免电流通过心脏。
3、做电针治疗时,对患者的刺激强度应以患者能耐受为度,不可拘泥于某一强度,在治疗中,医护人员应经常观察患者反应,若有异常,应立即采取切断电源,终止治疗。
低频电刺激治疗仪适用范围:本产品适用于非器质性失眠症患者的辅助治疗。
1.1产品型号划分说明HXND-□1.2结构组成HXND-A结构组成:主机(含台车)、电源线、2对导电耳夹。
HXND-B结构组成:主机、9V电池、1对导电耳夹。
1.3型号差异性说明,见表1表1 型号差异性说明2.1输出指示各型产品每个通道运行时均有显示屏显示。
2.2 治疗电流强度产品电流输出强度为70uA-400uA可调,误差±10%。
2.3 治疗电流频率产品治疗电流频率为0.1Hz,误差±10%。
2.4 输出脉冲宽度产品输出脉冲宽度为0.25s、0.5s、0.75s、和1s,误差±10%。
2.5 治疗时间2.5.1产品治疗时间都是20、30、40、50、60分钟五档可调。
2.5.2治疗时间误差±1min。
2.5.3产品开机运行初始默认治疗时间都是20分钟。
2.6 外观2.6.1 治疗仪外观应整齐、色泽均匀,无划痕、剥落等机械损伤和缺陷。
2.6.2 文字、符号、标志清晰。
2.7安全要求2.7.1通用安全要求应符合GB9706.1-2007《医用电气设备第一部分:安全通用要求》的规定,产品安全特征见附录A。
2.7.2 电磁兼容性要求:电磁兼容全面执行YY 0505–2012《医用电气设备第1-2部分:安全通用要求-并列标准:电磁兼容 - 要求和试验》标准要求。
2.7.3 环境试验要求应符合GB/T 14710-2009《医用电气设备环境要求及试验方法》规定的气候环境Ⅱ组、机械环境Ⅱ组及表2的要求。
表2环境试验补充规定。
ES-420功能障碍低频脉冲治疗仪配合吞咽训练治疗脑卒中后
吞咽困难29例效果观察
曹亚琴;袁宏周;醋爱英
【期刊名称】《齐鲁护理杂志:上旬刊》
【年(卷),期】2011(017)003
【摘要】目的:探讨使用ES-420功能障碍低频脉冲治疗仪配合吞咽训练治疗脑卒中后出现吞咽困难患者的疗效。
方法:将58例脑卒中后出现吞咽困难的患者随机分为治疗组与对照组各29例,对照组进行常规吞咽训练,治疗组使用ES-420功能障碍低频脉冲治疗仪治疗,并配合吞咽训练。
评价两组治疗效果。
结果:治疗组治疗总有效率为82.76%,对照组为65.51%,两组比较差异有统计学意义(P〈0.05)。
结论:使用ES-420功能障碍低频脉冲治疗仪配合吞咽训练治疗脑卒中后出现吞咽困难的患者,可提高治疗效果。
【总页数】2页(P77-78)
【作者】曹亚琴;袁宏周;醋爱英
【作者单位】宝鸡市中医医院,陕西宝鸡721001
【正文语种】中文
【中图分类】R473.5
【相关文献】
1.电针配合吞咽康复训练治疗脑卒中后吞咽困难60例 [J], 张俊杰
2.针刺配合低频脉冲电治疗脑卒中后吞咽困难36例 [J], 杨淑民
3.ES-420功能障碍低频脉冲治疗仪配合吞咽训练治疗脑卒中后吞咽困难29例效果观察 [J], 曹亚琴;袁宏周;醋爱英
4.吞咽功能障碍治疗仪治疗急性脑卒中后吞咽困难的疗效研究 [J], 张玉英;秦欢;李文蓉
5.吞咽功能障碍治疗仪联合咽部冰刺激治疗早期脑卒中后吞咽困难的疗效观察 [J], 张荣琴;苏润萍;陈媛;孙燕
因版权原因,仅展示原文概要,查看原文内容请购买。