Eaton 199199Eaton Moeller® series PKZM0 Motor-protective circuit-breaker, 5.5 kW, 8 - 12 A, Feed-side screw terminals/output-side push-in terminals, MSCGeneral specificationsEaton Moeller® series PKZM0 Motor-protective circuit-breaker199199PKZM0-12-SPI32401508197283875 mm 102 mm 45 mm 0.322 kgVDE 0660 IEC/EN 60947 UL File No.: E36332 IEC/EN 60947-4-1 CSA File No.: 165628UL Category Control No.: NLRV ULCSA-C22.2 No. 60947-4-1-14 CSA Class No.: 3211-05 CSAUL 60947-4-1 CE UL CSAProduct NameCatalog Number Model Code EANProduct Length/Depth Product Height Product Width Product Weight CertificationsTurn buttonPhase-failure sensitivity (according to IEC/EN 60947-4-1, VDE 0660 Part 102)Motor protectionPhase failure sensitiveThree-pole 100,000 operations100,000 OperationsDIN rail (top hat rail) mounting optionalCan be snapped on to IEC/EN 60715 top-hat rail with 7.5 or15 mm height.40 Operations/hIII3Motor protective circuit breakerFinger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)6000 V AC25 g, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 msAlso motors with efficiency class IE3Branch circuit: Manual type E if used with terminal, or suitable for group installations, (UL/CSA)≤ 0.25 %/K, residual error for T > 40°-5 - 40 °C to IEC/EN 60947, VDE 0660-25 - 55 °C, Operating rangeMotor starter combinations type MSC...Actuator type Features Functions Number of poles Lifespan, electricalLifespan, mechanicalMounting MethodMounting positionOperating frequencyOvervoltage categoryPollution degreeProduct categoryProtectionRated impulse withstand voltage (Uimp) Shock resistanceSuitable forTemperature compensationUsed withMax. 2000 m-25 °C55 °C25 °C40 °C40 °C80 °CDamp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-301 x (1 - 6) mm²12 mm1.7 Nm, Screw terminals, Main cable50 Hz60 Hz12 A3 kW5.5 kW690 V690 V12 A18 kA, 240 V, SCCR (UL/CSA)18 kA, 480 Y/277 V, SCCR (UL/CSA) 18 kA, 600 Y/347 V, SCCR (UL/CSA) 65 kA, 240 V, SCCR (UL/CSA)65 kA, 480 Y/277 V, SCCR (UL/CSA)186 A, Irm, Setting range max.Basic device fixed 15.5 x Iu, Trip Blocks 0.5 HP 3 HP2 HP3 HPAltitudeAmbient operating temperature - minAmbient operating temperature - maxAmbient operating temperature (enclosed) - min Ambient operating temperature (enclosed) - max Ambient storage temperature - minAmbient storage temperature - maxClimatic proofing Terminal capacity (flexible)Stripping length (main cable)Tightening torqueRated frequency - minRated frequency - maxRated operational current (Ie)Rated operational power at AC-3, 220/230 V, 50 Hz Rated operational power at AC-3, 380/400 V, 50 Hz Rated operational voltage (Ue) - minRated operational voltage (Ue) - maxRated uninterrupted current (Iu)Short-circuit current rating (type E) Short-circuit release Assigned motor power at 115/120 V, 60 Hz, 1-phase Assigned motor power at 200/208 V, 60 Hz, 3-phase Assigned motor power at 230/240 V, 60 Hz, 1-phase Assigned motor power at 230/240 V, 60 Hz, 3-phase± 20% tolerance, Trip blocks7.5 HP10 HPPush-in terminals on output sideScrew terminals on feed side12 A12 AOverload trigger: tripping class 10 A 6.64 W0 W0 W0 WMeets the product standard's requirements.Meets the product standard's requirements.Meets the product standard's requirements.Meets the product standard's requirements.Meets the product standard's requirements.Does not apply, since the entire switchgear needs to be evaluated.Assigned motor power at 460/480 V, 60 Hz, 3-phase Assigned motor power at 575/600 V, 60 Hz, 3-phaseConnection Number of auxiliary contacts (change-over contacts)Number of auxiliary contacts (normally closed contacts)Number of auxiliary contacts (normally open contacts)Overload release current setting - min Overload release current setting - max Tripping characteristic Equipment heat dissipation, current-dependent PvidHeat dissipation capacity PdissHeat dissipation per pole, current-dependent PvidStatic heat dissipation, non-current-dependent Pvs10.2.2 Corrosion resistance10.2.3.1 Verification of thermal stability of enclosures10.2.3.2 Verification of resistance of insulating materials to normal heat10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects10.2.4 Resistance to ultra-violet (UV) radiation10.2.5 LiftingDoes not apply, since the entire switchgear needs to be evaluated.Meets the product standard's requirements.Does not apply, since the entire switchgear needs to be evaluated.Meets the product standard's requirements.Does not apply, since the entire switchgear needs to be evaluated.Does not apply, since the entire switchgear needs to be evaluated.Is the panel builder's responsibility.Is the panel builder's responsibility.Is the panel builder's responsibility.Is the panel builder's responsibility.Is the panel builder's responsibility.The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.Is the panel builder's responsibility. The specifications for the switchgear must be observed.Is the panel builder's responsibility. The specifications for the switchgear must be observed.The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.Save time and space thanks to the new link module PKZM0-XDM32ME Motor Starters in System xStart - brochureProduct Range Catalog Switching and protecting motorsSwitching and protecting motors - catalogDA-DC-00004887.pdfDA-DC-00004917.pdfeaton-manual-motor-starters-pkz-dimensions-002.epseaton-manual-motor-starters-pkzm-pkzm0-dimensions-003.eps121X002121X042eaton-manual-motor-starters-pkz-dimensions.epsETN.PKZM0-12-SPI32.edzIL122024ZUWIN-WIN with push-in technologypkzm0_s32_pi.stppkzm0_s32_pi.dwg10.2.6 Mechanical impact10.2.7 Inscriptions10.3 Degree of protection of assemblies10.4 Clearances and creepage distances10.5 Protection against electric shock10.6 Incorporation of switching devices and components 10.7 Internal electrical circuits and connections10.8 Connections for external conductors10.9.2 Power-frequency electric strength10.9.3 Impulse withstand voltage10.9.4 Testing of enclosures made of insulating material 10.10 Temperature rise10.11 Short-circuit rating10.12 Electromagnetic compatibility10.13 Mechanical function BrochuresCatalogsDeclarations of conformity DrawingseCAD modelInstallation instructions Installation videosmCAD modelEaton Corporation plc Eaton House30 Pembroke Road Dublin 4, Ireland © 2023 Eaton. All Rights Reserved. Eaton is a registered trademark.All other trademarks areproperty of their respectiveowners./socialmedia。
PCS-9621站用变保护测控装置
应用概述
PCS-9621适用于110kV以下电压等级的非直接接地系统或小电阻接地系统中的站用变或接地变
的保护及测控装置。
可组屏安装,也可在开关柜就地安装。
该保护装置可实现对断路器、隔离刀闸的分/合操作;同时能够对保护对象间隔单元的电压、电
流、功率等进行实时测量。
可以和监控系统进行通讯;通讯规约可选择IEC 60870-5-103或
IEC 61850。
•
数字化变电站功能
装置提供电子式互感器接口,支持IEC60044-8接口协议,借助多模光纤由合并单元引入电压量和电流量
合并单元传入的电压电流量的采样速率为4k/s或者5k/s。
支持IEC-61850通讯规约。
保护功能
三段复合电压闭锁过流保护
高压侧正序反时限保护
过负荷报警
两段定时限负序过流保护:其中Ⅰ段用作断相保护,Ⅱ段用作不平衡保护
高压侧接地保护:三段定时限零序过流保护(其中零序Ⅰ段两时限,零序Ⅲ段可整定为报警或跳闸)、零序过压保护、支持网络小电流接地选线
低压侧接地保护:三段定时限零序过流保护、零序反时限保护
低电压保护
非电量保护:重瓦斯跳闸、轻瓦斯报警、超温跳闸或报警、一路备用非电量跳闸、一路备用非电量跳闸或报警
闭锁简易母差GOOSE输出功能。
独立的操作回路及故障录波
测控功能
11路自定义遥信开入
Iam、Ibm、Icm、I0、UA、UB、UC、UAB、UBC、UCA、U0、f、P、Q、COSф共15个遥测量
一组断路器遥控分/合(选配方式至多可提供五组遥控)
事件SOE记录等。
PCS-9686_100137电铁馈线保护测控装置简介:PCS-9686装置适用于并联自耦变压器(AT)供电方式、串联吸流变压器(BT)与回流线的供电方式、直接供电(带回流线与不带回流线)方式的电气化铁道牵引变电所、开闭所及分区所。
保护配置:四段自适应距离保护(可经二次谐波闭锁、PT 断线闭锁、高次谐波抑制、三段可整定为反时限、四段固定为反时限)三段式高阻接地保护(含电流增量保护,可经低压启动、高次谐波抑制) 三段式过流保护(可经低压启动、高次谐波闭锁,其中三段可整为反时限) 加速保护(可整定前加速或者后加速) 过负荷功能 (可整定报警或者跳闸) 失压保护 过压保护二次谐波闭锁功能 三相一次重合闸 过流闭锁出口功能 出口组态功能 低电压启动功能 高次谐波抑制功能 PT 断线闭锁功能 上下行联锁功能 故障测距独立的操作回路及故障录波软件工作原理:对于采用交——直电力机车牵引的电气化铁道,尤其是对于重载线路,牵引重负荷与再生制动电流迭加和牵引重负荷与励磁涌流迭加都有可能导致常规阻抗保护的误动作,同时,无论机车上是否装有功率因数补偿装置,牵引网负荷电流中总是或多或少地存在谐波分量。
本装置就是利用负荷电流中的综合谐波含量作为控制量,自适应地调节阻抗继电器的动作边界。
如常规阻抗继电器的动作边界为Zzd ,则自适应阻抗继电器的动作边界为:23511dz zd Z Z k =⋅+式中: 1532235/)(I I I I K ++=为综合谐波含量 。
注: ①三段自适应阻抗元件边界;②元件边界(可调)③ 元件边界;④有谐波后阻抗I 段边界; R 1: I 段阻抗定值; R 01: I 段偏移阻抗定值; X 1: I 段电抗定值; X 01: I 段偏移电抗定值;I ∆)(I /)(R m e m m Z ZAB 边的调节原则 整定:当保护围末端短路时,继电器应能可靠动作,即:xl k zd X K X ⋅= 式中: k K ——可靠系数,取1.1~1.2 调节为了避免被保护线路上同时存在多列车分别工作在牵引、再生或启动工况下时继电器误动作,利用上述工况下谐波含量自动调节其动作边界,即:2351Kxldz K X X K =⋅+BC 边的调节原则 整定:BC 边的整定是按基波最小负荷阻抗整定的,即:)/sin (cos min 1θtg ΨΨZ K R f k zd -⋅⋅=式中: Ψ——功率因数差时的负荷阻抗角θ ——BC 边的倾斜角,即线路阻抗角,围60°~80°。
cascadeாFor Technical Assistance and to Order Parts . . .Serial NumberModel c Parts ManualPush-Pull 35E-QB-167PublicationsTO O L C A T A L O GPA R T S M A N U A LSE RVI CE M AN UA LGA0006.epsINS T AL LA T I O N I N S TR M cascade Ordering Information FAX:Mail:Phone:513-325-9270Cascade Corporation513-322-1199P .O. Box 360Springfield, Ohio 45501aster Service Manual –Part No. 673969Service Literature Index and Order Formcascade PERATOR’S GUIDEOPART NO.DESCRIPTIONParts Manual 686455Service Manual 684945Operators Guide685531Operators Pocket Guide 684944Installation Instructions680664Servicing Cascade Cylinders-VHS 679929Tool Catalog673964Literature Index Order FormDecals35E/45E Sheet–SavDecals35E/45E QFM™ Sheet–SavPlatensNOTE: Usable platen lengths are determined by measuringplaten from end to end.REF QTY PART NO.DESCRIPTION683196Platen Group11683198Platen R. H.21683197Platen L. H.38768705Capscrew48773842NutFrame Group ITA II35E/45EREF QTY PART NO.DESCRIPTION204625Frame Group with Platens 11205019Frame with Platens 212453Fitting, 6-6332680Fitting, 6-6412375Fitting, 6-651683186Tube 61683187Tube 72763025Nut82681473Lockwasher 92676280Hook104768554Capscrew 114667910Washer 122683188Pivot Hook 132768837Capscrew 142683189Pin Assembly 152204938Setscrew 1625930Nut$#@9!81234562%^7PP0077.ill° ! #4°&)&(#!°5^$#°@!#%›fl ° ‡‹ 645& 987126!4%*¤^!#⁄53# ! °#! 3 5 )# ! ° fi^54*5 4 & 4⁄( PP0086.ill35E/45EREF QTY PART NO.DESCRIPTION204644Mechanism Group 11204691Arm-Inner Secondary R. H.21204692Arm-Secondary Outer R. H.34683154s Bushing4q683161Shim (.030)5q683162Shim (.060)64205070Roller7q683163Shim (.030)8q683164Shim (.060)94683155s Bushing101682821Pin11156229Washer122685661Capscrew1315682999Eye-Pin142682822Pin-Head152205065Pin166683153s Bushing17q204532Shim (.12)182204694Arm-Outer Primary 194204533Pin-Frame204204535s Bushing214204695Pin221204604Arm-Inner Primary 231204693Arm-Secondary Outer L. H. 241204690Arm-Inner Secondary L. H. 252204696Pin-Outer262682823Pin-Rod272683165Spacer2813767961Capscrewq Quantity as required.s Included in Bushing Service Kit 205075.CylinderREF QTY PART NO.DESCRIPTION582635Cylinder Assembly 11 ---Spacer 21562552Seal s 317348Snap Ring 41562334Piston 51562716Shell 61558626Rod 71559705Seal s 812785O-Ring s91615128Back-Up Ring s 101559696Retainer 111636853Wiper s 124559697Bearing 131559698Spacer 141678019Nut151671047Seal Loader Kit ss Included in Service Kit 562338.Ref: S-34242.0" D I A .%5@#2$46310!7@98PP0043.illHydraulic Group REF QTY PART NO.DESCRIPTION 685828Hydraulic Group ITA II 11685831Hose 22683173Hose312375Fitting, 6-648604511Fitting, 6-651682812s Valve62765329Capscrew, M8x1.25x20-8.872685978Hose ITA II 82684956Cable tie 94605235Fitting 5-6101200647Tube 112604510Plug, 6121200649Tube 131200648Tubes See Valve page for parts breakdown.7294089419@#9!35464PP0036.ill35E/45EValveLoad Push/Pull35E/45EREF QTY PART NO.DESCRIPTION682812Valve Assembly11677125Sequence Valve (Retract)22669597Service Kit 31682813Body 45663694Fitting, 351677124Sequence Valve (Extend)61659058Gripper Check Valve 71667516Service Kit74132562PB P R G R GB PP0041.illFaceplate Group35E/45EREFQTYPART NO.DESCRIPTIONREF QTY PART NO.DESCRIPTION205970Faceplate Group 40" x 40" s 205963Gripper Jaw Assembly q 11204634Faceplate 40" x 40" s 21205959Junction Block 31206396Gripper Jaw 42673385Drive Pin52682844Gripper Cylinder w 68617915Fitting, 4-472200877Drive Pin 81206403Gripper Bar 91672712Gripper Pad1056444Lockwasher115768794Capscrew, M8x1,25x20-8.8122604511Fitting, 6-6132686573Bearing 142205957Hose 152205958Hose162768710Capscrew 172609234Plug, 4184779010Capscrew192763166Capscrew, M8x1,25x25-8.8204---Stops Width x heigth.q Includes items 2 through 20.w See Gripper Cylinder page for parts breakdown.543(2)^*@&6%$%$#!789PP0039.illGripper Cylinder682844Gripper Cylinder w 11646540Seal w 21636850Wiper w 312718O-Ring w 412710O-Ringw 51615122Back-Up Ring 61685662Shell 71685663Rod 81685664Retainer 91685665Piston 101563462Nut 111563916Ring121684284Snap Ring w 131663728Piston Seal35E/45EREF QTY PART NO.DESCRIPTIONw Included in Service Kit 684827.#4890@!532671PP0038.illDo you have questions you need answered right now? Call your nearest Cascade Parts Department.Cascade (UK) Ltd.15, Orgreave Crescent Dore House Industrial Estate HandsworthSheffield S13 9NQEnglandTel: 742-697524FAX: 742-695121Cascade Scandinavia Hydraulik A.B.Muskötgatan 19, E8-9 S25466 Helsingborg SwedenTel: 42-151135FAX: 42-152997Cascade N.V. European Headquarters P.O. Box 30091300 El Almere Damsluisweg 561332 ED AlmereThe NetherlandsTel: 31-36-5492911 FAX: 31-36-5492964Cascade France S.A.R.L. 11, Rue Jean Charcot Zone Industrielle Sud or B.P. 2291421 Morangis Cedex FranceTel: 1- 64547500FAX: 1-64547501Cascade Hispania S.A.Avenida De La Fabregada, 7Hospitalet De LlobregatBarcelonaSpainTel: 3-335-5158FAX: 3-335-4756Cascade Japan Ltd.5-5-41,Torikai KamiSettsu, OsakaJapan, 566Tel: 81-726-53-3490FAX: 81-726-53-3497HYCO-Cascade Pty. Ltd.87 Antimony Street Carole Park,Brisbane 4300AustraliaTel: 7-271-1966FAX: 7-271-3830HYCO-Cascade (NZ) Ltd.23 Haseler CresentP.O. Box 38-440Howick, AucklandNew ZealandTel: 9-273-9136FAX: 9-273-9137Cascade (Africa) Pty. Ltd.P.O. Box 625, Isando 160060A Steel RoadSparton, Kempton ParkSouth AfricaTel: 975-9240FAX: 394-1147Sunstream Industries PTE Ltd.No. 3 Tuas Link 1 Singapore 2263Tel: 863-3488FAX: 863-1368Cascade Canada Inc.5570 Timberlea Blvd.Mississauga, OntarioCanada L4W-4M6Tel: 905-629-7777FAX: 905-629-7785Cascade GmbHD-41199 MonchengladbachKlosterhofweg 52GermanyTel: 21-66-602091FAX: 21-66-680947Cascade N.V.Benelux Sales and ServiceP.O. Box 30091300 El AlmereDamsluisweg 561332 ED AlmereThe NetherlandsTel: 31-36-5492950FAX: 31-36-5492974Cascade N.V.Kirkkokatu 148100 KotkaFinlandTel: 52-184393FAX: 52-184833Cascade Corporation2201 NE 201stTroutdale, OR 97060Tel:1-800-CAS-CADE503-669-6300FAX: 503-669-6338Cascade KoreaRoom 508, Pum Yang Bldg.750-14, Bang Bac-DongSe-Cho Ku, SeoulKoreaTel: 2599-7131 ext. 512FAX: 2533-8089Cascade-XiamenWanshan No. 1 WorkshopHuli RoadXiamen 361006Fujian, PRCTel: 592-562-4600FAX: 592-562-4671c。
干式空心电抗器安装使用说明书北京电力设备总厂2002.11概况北京电力设备总厂创建于1952年,原名为北京发电设备修造厂,1984年9月改名为北京电力设备总厂(简称BPEG),是电力系统最大的综合性制造厂家,也是我国生产制造玻璃钢包封干式空心电抗器最早的专业制造厂。
BPEG从1989年开始生产干式空心电抗器,目前设计制造的产品种类和产品数量,均属国内最大的制造厂家。
本说明书是干式空心电抗器的基本说明,请用户在验收、安装、检测和运行前详细阅读。
如本说明仍有不详之处,请与北京电力设备总厂销售或技术部门联系,我们将为您提供热情周到的服务。
常用干式空心电抗器类型及用途1.并联电抗器(BKK)—并联连接在500kV变电站或220kV变电站低压绕组侧,用于长距离轻负荷输电线路的电容性无功补偿。
2.可控硅控制电抗器TCR(BKK—2×)—由两台容量相同的并联电抗器叠装组成单相,三相电抗器一般按△接法连接,由可控硅控制其通过容量。
用于静补装置。
3.串联电抗器(CKK)—在并联补偿装置中,与并联电容器串联连接,用以抑制谐波分量和限制电容器回路投入时的合闸涌流。
4.串联可调电抗器(CKKT)—在并联补偿装置中,与并联电容器串联连接,用以抑制谐波分量和限制电容器回路投入时的合闸涌流。
一般用于电气化铁路无功补偿。
5.限流电抗器(XKK)—串联连接在系统中,在系统发生故障时,用以限制短路电流,使短路电流降低至允许值。
6.滤波电抗器(LKK)—与并联电容器组串联连接,组成谐振回路,滤除指定的高次谐波。
7.可调滤波电抗器(LKKT)—电感值可调滤波电抗器。
8.平波电抗器(PKK)—在直流系统中为谐波电流提供高阻抗和在故障时减小电流增加。
9.阻尼电抗器(ZKK)—与电容器串联,用来限制电容器组投入时的涌流。
10.分裂电抗器(FKK)—安装在保持隔离的两个分离馈电系统中,正常运行时电感较低,出现故障时,则对系统呈现出较大的阻抗以限制故障电流。
苏州向阳220kV变电站第3台主变扩建工程安全组织技术措施苏州电力建设工程有限公司2017年6月审批页审批:年月日安全部门:年月日质量部门:年月日技术部门:年月日编写:年月日一、工作概况及施工作业特点1.1情况简介(一)、建设规模本站前期已建设2台180MVA主变,本期扩建1台180MVA三相三圈无励磁调压自冷型变压器(#3主变)、220kV主变进线间隔、110kV主变进线间隔及35kV主变进线间隔;扩建1×10Mvar并联电容器和1×10Mvar并联电抗器;220kV 、110kV 及35kV 出线不变;220kV 及110kV 维持双母接线。
本期220kV、110kV、35kV均不新增出线。
(二)、工程量(1)主变安装1、本期扩建1台180MVA主变,主变型号SS-180MVA/220kV,电压等级为220/118/37.5/15kV。
接线方式YNyn0yn0+d11。
2、排油充氮灭火装置1台,型号DDM型3、高压中性点成套1套,型号BZFZ-2204、主变220kV侧SF6断路器1台,型号LTB245E1-3P。
GW20-252DW型隔离开关1组、GW12A-252W型隔离开关1组、GW12A(34)-252DW型隔离开关1组。
220kV电流互感器LVB-220W3型3台,Y10W1-204/532W型氧化锌避雷器3支。
5、主变110kV侧SF6断路器1台,型号LW35-126。
GW16B-126型不接地式隔离开关1组、135°安装。
GW16B-126型单接地式隔离开关1组、135°安装。
GW4-126VI DW型双接地式隔离开关1组。
110kV电流互感器LVB1-110W3型3台,Y10W-102/266型避雷器3支。
6、主变35kV侧母线桥安装、GW4D-40.5IID(W)型双接地式隔离开关1组、Y5WZ-51/134型避雷器3支。
电力电缆YJV22-26/35-1×630电缆敷设,终端头制作安装7、35kV开关柜(ASN1-40.5)4面。
Eaton PDD32P0125TFAKPower Defense UL/CSA 240V Max, Frame 3, Two Pole, 125A, 200kA/240V, T-M (Fxd-Adj) TU, Std Term Line Only (PDG3X2TA300)Eaton Power Defense molded case circuit breakerPDD32P0125TFAK 786679988152109.1 mm 257.1 mm 138.9 mm 5.2163 kg Eaton Selling Policy 25-000, one (1) year from the date of installation of theProduct or eighteen (18) months from thedate of shipment of the Product,whichever occurs first.RoHS Compliant CSAUL 489Product NameCatalog Number UPCProduct Length/Depth Product Height Product Width Product Weight WarrantyCompliancesCertifications125 AComplete breaker 3Two-polePD3 UL/CSA Only Class A T-M (Fxd-Adj) TU240 V AC240 VStandard Terminals Line Only200 kAIC at 240 Vac 200 kAIC @240V (UL) 22 kAIC Icu @250 VdcEaton Power Defense PDD32P0125TFAK 3D drawing Consulting application guide - molded case circuit breakers StrandAble terminals product aid Power Defense technical selling booklet Power Defense brochurePower Defense molded case circuit breaker selection poster PDG3 UL authorization 100-400a PDG3 UL authorization 250-600a TMTUAmperage Rating Circuit breaker frame type Frame Number of poles Circuit breaker type Class Trip Type Voltage rating Voltage rating - max TerminalsInterrupt rating Interrupt rating range 3D CAD drawing packageApplication notesBrochuresCertification reportsEaton Corporation plc Eaton House30 Pembroke Road Dublin 4, Ireland © 2023 Eaton. All Rights Reserved. Eaton is a registered trademark.All other trademarks areproperty of their respectiveowners./socialmediaPower Defense Declaration concerning California’s Proposition 65Power Defense Frame 3 Breaker Instructions (IL012107EN).pdf Power Defense Frame 3 Variable Depth Rotary Handle Mechanism Installation How-To Video Power Defense BreakersPower Defense Frame 6 Trip Unit How-To Video Eaton Power Defense for superior arc flash safety Power Defense molded case circuit breakersPower Defense Frame 2 Variable Depth Rotary Handle Mechanism Installation How-To VideoPower Defense Frame 5 Trip Unit How-To Video Eaton Specification Sheet - PDD32P0125TFAK Power Defense time current curve Frame 3 - PD3Molded case and low-voltage breaker health Safer by design: arc energy reduction techniquesInstallation instructionsMultimediaSpecifications and datasheetsTime/current curvesWhite papers。