DimensionsF3, F5, F6, F7 Solenoid ValvesF3, F5, F6, F7 Remote Pilot ValvesDimensionsTable 1Compression Factors and “A” Constants“A” Constants for VariousInlet CompressionPressure Drop *Pressure Factor2 PSI 5 PSI 10 PSI (PSIG)∆ P ∆ P ∆ P10 1.6.155.10220 2.3.129.083.06630 3.0.113.072.05540 3.7.097.064.04850 4.4.091.059.04360 5.1.084.054.04070 5.7.079.050.03780 6.4.075.048.035907.1.071.045.0331007.8.068.043.0311108.5.065.041.0301209.2.062.039.0291309.9.060.038.02814010.6.058.037.02715011.2.056.036.02616011.9.055.035.02617012.6.054.034.02518013.3.052.033.02419014.0.051.032.02420014.7.050.031.023Note: Use “A” constant at 5 PSI ∆ P for most applications. On very criticalapplications, use “A” at 2 PSI ∆ P. You will find in many cases, a 10 PSI ∆ P is not detrimental, and can save money and mounting space.*68°F and G =1 for Air.DefinitionsCE ...................Certification of a product to meet EuropeanCommunity standards. “F” Series solenoid valves are approved for CE.CSA/NRTL-C ..Canadian Standards Association and ULApplicable. (See page 23)IP65.................International classification system forsealing effectiveness for enclosures of electrical equipment. IP stands for “Ingress Protection” and the two digits XY stand for:X - protection from solid objects and Y -protection from moisture. IP65 is protection from dust and water washdown.NEMA 4...........National standard for enclosure protection.NEMA 4 provides protection against dirt,dust, water hosedown and rain. (More stringent than IP65)NLMOR ...........Non-Locking Manual Override. A constantactuation must be maintained for the valve to remain shifted.LMOR ..............Locking Manual Override. Valve remainsshifted without constant end user override actuation.Surge SuppressionNullifies reverse EMF generated when a solenoid is de-energized. “F” Series Voltage Code 12, 15, 19, 23, 83, and 87 include surge suppression.Bi-Polar ...........Solenoids are non-polarity sensitive and canbe reverse wired. All “F” Series solenoids are non-polarity sensitive.SCFM ..............Measure of air flow. Standard Cubic Feetper Minute at 68°F and 36% humidity at sea level.PSIG ................Pounds per Square Inch measured with agage. (Catalog pressure reflects PSIG)PSIA ................Pounds per Square Inch atmospheric.kPa ..................Kilopascals. International measure ofpressure. 145 PSIG = 1000 kPaPSIG = 0 In. of Hg = 29.92 kPa = 0C v CalculationsC v ............Measure of calculating flow of a valve (or otherpneumatic device) that takes into effect the temperature, pressure, pressure drop, and flow.As a rule of thumb, a Cv of 1.0 is 25 SCFM with a 5 PSIG pressure drop.Cylinder Area Cylinder Compression “A”(Sq. In.)X Stroke X Factor X(T able 1)C v =(See Table 2)(In.)(T able 1)Stroke Time (sec.) x 28.8Table 2Effective Square-Inch Areas for Standard-Bore-Size CylindersBoreCylinder Area Bore Cylinder Area Size(Sq. In.)Size(Sq. In.)3/4".444"12.571".7941/2"15.9011/8".995"19.6411/4" 1.236"28.2711/2" 1.777"38.4813/4" 2.418"50.272" 3.1410"78.5421/2" 4.9112"113.1031/4"8.3014"153.9435/8"10.32Product Shipping WeightsPlug-In Subbase ValvesDefinitions & Weights。
D3-D11 UK.INDD RH 06.09.2011Pilot Operated Directional Control Valves Series D31DW, D31NW, D*1VWCatalogue HY11-3500/UK2CharacteristicsThe pilot operated valves are available in 4 sizes:D31DW NG10 (standard)D31NW NG10 (high flow)D41VW NG16D81VW NG25 (for port diameter up to 26 mm)D91VW NG25 (for port diameter up to 32 mm)D111VWNG32All valves are piloted by a D1VW valve. The valves can be ordered with position control. Please see the separate ordering code.The minimum pilot pressure must be ensured for all op-erating conditions of the directional valve.Additionally spools with a P to T connection in the de-energized position need an external pressure supply (external inlet) or an integral check valve.D81VWD31DWD31NW D41VWD81VW D111VWPilot Operated Directional Control Valves Series D31DW, D31NW, D*1VWD3-D11 UK.INDD RH 06.09.2011Catalogue HY11-3500/UK2Ordering CodeSpoolSeriesSpool 1)2)Not for D31NW available 3)Not for D31NW and D111VW available 4)For D31NW and D111VW only pilot valve with detent availableD3-D11 UK.INDD RH 06.09.2011Pilot Operated Directional Control Valves Series D31DW, D31NW, D*1VWCatalogue HY11-3500/UK2Ordering CodeSolenoid options Solenoid voltageDesign series(not required for ordering)Pilot oil supply and drain optionsAcces-sories Further spool types and solenoid voltages on request.Explosion proof solenoids EEx me ll see catalogue HY11-3343. Download:/euro_hcd - see “Literature”Connector as per EN 175301-803,without plug(Please order plugseparately)Seals Code Seals N NBR VFPM Code Accessories omit Standard valve w/o accessories 3A Pilot choke, meter-out 3B Pilot choke, meter-in 3C Pilot with pressure reducing valve 3D 8)Stroke adjustment side B 3E 8)Stroke adjustment side A3F 8)Stroke adjustment side A and B 3R meter-out + pressure reducing valve 1Tmeter-in + pressure reducing valveCode Solenoid option omit Standard solenoid without options T without manual override 7)To be used in combination with rectifier plugs at 120VAC / 230VAC power sup-ply.Code Solenoid voltageK 12V =J 24V =U 7)98V =G 7)205V =Y 110V 50Hz / 120V 60Hz T230V 50Hz / 240V 60Hz5)N ot for D31DW, D91VW and D111VW available.6) N ot for spools 002, 007, 009, 014, 030, 031, 032, 054 available.Code Inlet Outlet 1Internal External 2External External 3 5)Integral check valve External 4 6)Internal Internal 5External Internal 6 5)Integral check valveInternal8)Only D31, D41, D81, D91 available.WCatalogue HY11-3500/UK2Ordering CodeWith inductive position controlPilot Operated Directional Control ValvesSeries D31DW, D*1VW Induct. Position ControlD3-D11 UK.INDD RH 06.09.2011D3-D11 UK.INDD RH 06.09.2011Catalogue HY11-3500/UK2Ordering Code6)The plug M12 x 1 for the position control is included. The monitor switch has to be located on the side to which the spool moves from the spring offset position. For 4/3-way valves two switches are used.Pilot oil supply and drain options4)To be used in combination with rectifier plugs at 120VAC / 230VAC power supply.Code Solenoid voltageK 12V =J 24V =U 4)98V =G 4)205V =2)N ot for D31DW, D91VW and D111VW available..3) N ot for spools 002, 007, 009, 014, 030 available.Code Inlet Outlet 1Internal External 2External External 3 2)Integral check valve External 4 3)Internal Internal 5 External Internal 6 2)Integral check valveInternalCode Solenoid option omit Standard solenoid without options T 5)without manual override5)For hydraulic presses according to the safety regulations EN 693, solenoid op-tion “T“ (without manual override) and accessories “I4N“, “I5N“ or “I6N“ (start position monitored) are required.Solenoid optionsSolenoid voltage Design series(not required for ordering)Acces-sories Connector as per EN 175301-803,without plug(Please order plugseparately.SealsCode Seals N NBR VFPM Code Spool positionPosition control I3NCEnd positionmonitored, side A and BI6N6)Start positionmonitored, side A and BI2N C, B, E, F (all spools)C, K, M (spool 9)End position monitored, side B I5N 6)Start position monitored, side B I1N C, H, K, M (all spools)C, E, F (spool 9)End position monitored, side A I4N 6)Start position monitored, side AAttentionThe adjustment of the position control is factory set and sealed.Replacement and repairs can only be undertaken by the manufacturer.WPilot Operated Directional Control ValvesSeries D31DW, D*1VW Induct. Position ControlPilot Operated Directional Control Valves Series D31DW, D31NW, D*1VWD3-D11 UK.INDD RH 06.09.2011Catalogue HY11-3500/UK2Technical DataWith electrical connections the protective conductor (PE W ) must be connected according to the relevant regulations.D3-D11 UK.INDD RH 06.09.2011Pilot Operated Directional Control Valves Series D31DW, D31NW, D*1VWCatalogue HY11-3500/UK2Electrical characteristics of position control M12x1Position ControlM12 pin assignment1 Us 18 (42V)2 Out B: normally open3 0V4 Out A. normally closed 5Earth groundDefinitionsStart position monitored:The valve is de-energized. The inductive switch gives a signal at the moment when the spool leaves the spring offset position (below 15% spool stroke).At the switching point the spool is located within the closed position. It is secured that only the flow paths of the offset position are granted.The switch can only be located on the opposite side of the solenoid for direct operated valves.Delivery includes plug M12 x 1 (see accessories, plug M12x1; order no.: 5004109).End position monitored:The inductive switch gives a signal before the end position is reached (above 85% spool stroke).Pilot Operated Directional Control Valves Series D31DW, D31NW, D*1VWD3-D11 UK.INDD RH 06.09.2011Catalogue HY11-3500/UK2Flow Curve DiagramsD31DW and D41VWThe flow curve diagram shows the flow versus pressure drop curves for all spool types. The relevant curve number for each spool type, operating position and flow direction is given in the table below.All characteristic curves measured with HLP46 at 50°C.D31NWD31DWD31NWD3-D11 UK.INDD RH 06.09.2011Pilot Operated Directional Control ValvesSeries D31DW, D31NW, D*1VWCatalogue HY11-3500/UK2Flow curve D31NWD81/D91VW and D111VWFlow curve D81VWFlow curve D41VW Flow Curves / Integral Check ValveIntegral check valve in the P portMounting an integral check valve in the P port is necessary to build up pilot pressure for valves with P to T connection and internal pilot oil supply. The pressure difference at the integral check valve (see performance curves) is to be added to all flow curves of the P-port of the main valve. Directional valves with an integral check valve are availablefor the series D31NW, D41VW and D81VW.All characteristic curves measured with HLP46 at 50°C.Pilot Operated Directional Control Valves Series D31DW, D31NW, D*1VWD3-D11 UK.INDD RH 06.09.2011Catalogue HY11-3500/UK2open,closedM6 DIN906M6 DIN906Slip-in orifice in pilot p-port(drawn offset)All orifice sizes for standard valvesPilot oil inlet (supply) and outlet (drain)Series D31DWSeries D41VWSeries Series Pilot Oil OptionsPilot Operated Directional Control Valves Series D31DW, D31NW, D*1VWCatalogue HY11-3500/UK2D31NWD31DWDimensionsThe space necessary to remove the plug per EN 175301-803, design type AF is at least 15 mm. The torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm.* Please add for each sandwich plate +40mm (pressure reducing valve, choke valve meter-in/-out).* Please add for each sandwich plate +40mm (pressure reducing valve, choke valve meter-in/-out).Pilot Operated Directional Control Valves Series D31DW, D31NW, D*1VWCatalogue HY11-3500/UK2DimensionsThe space necessary to remove the plug per EN 175301-803, design type AF is at least 15 mm. The torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm.D81VW, D91VWD41VW* Please add for each sandwich plate +40mm (pressure reducing valve, choke valve meter-in/-out).* Please add for each sandwich plate +40mm (pressure reducing valve, choke valve meter-in/-out).Pilot Operated Directional Control ValvesSeries D31DW, D31NW, D*1VW Catalogue HY11-3500/UK2 D111VWDimensionsThe space necessary to remove the plug as per EN 175301-803, design type AF is at least 15 mm.The torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm.* Please add for each sandwich plate +40mm (pressure reducing valve, choke valve meter-in/-out).Catalogue HY11-3500/UKNotes。
Truck Mounted Cranes Directional Control Valve Application SolutionsParker’s V20 directional control valve is a proven performer in this market. It has very low pressure drops and optimized metering spools designedspecifically for these machines.Other features include:•Integrated unloading valves for anti-tip control•Integrated solenoid to control the functionality of the unloading valves•Solenoid selectable power-beyond for two speed winch operation•Neutral interlock positioner •For radio-remote operation, an integrated section to generate and regulate the pilot signal to the work-section solenoids •Work-section proportionalsolenoids with push pin overridesTruck Mounted CranesParker offers a full line of directional control valves,hydraulic controllers and crane specific solutions for this market.Series V20 ValveDirectional control valve assembly with integrated unloading valves for lift andtele and selectable winch boostParker has developed application specific control solutions for this market, which are intended to improve machine performance and lower the installed cost. Our long standing application knowledge of these machines has enabled Parker to develop features truly valued by the customer and the end-user.Solenoid selectablepower-beyond outletUnloading valve for work ports and two speedwinch operation•Broad offering of port accessories•Pressures up to 3500 PSI •Flows up to 25 GPM •Open-center & Load-senseSeries V20EH ValveThe electrohydraulic package for the V20 includes an on-demand pressure-generating / regulation section. This means that when the spools are in neutral, the open-center pressure drop is low; ~75 PSI @ 20 GPM for a 4-spool assembly.When a spool is selected, a signal is sent to the pressure-generating section to build enough pressure to move the spool.Solenoid Features•Can be used for proportional or on/off control•Available in 12V and 24V •Connector options are Deutsch, Amp Jr and Weatherpak •Pushpin overrides are availableSeries VG20 ValveUsed on winch application with flows from 25-45 GPM. Features:•45 GPM, 3500 PSI •Low pressure drops•Available with unloading valves for anti-tube lock (anti-two block)Outrigger Solution Series MD06 Valve•Direct shift solenoid valve. Does not require any pilot pressure.•Modular design allows for bolt-on options for port accessories.•Available in 2 or 3 position,4-way valves•Flows up to 25 GPM •Pressures up to 3000 PSIOur hydraulic-remotecontrollers have spring packs that optimize the controllability of our directional control valves. They are compact and can fit into the armrest for finger-tip control.Series PCL ControllersSeries V20 Valve with an Integrated ManifoldCustom designed manifold integrated into a V20 to add features and reduce cost for a specific vehicle.•Outstanding relief valve performance•Available spool positioners are manual, pilot and EH.Parker Hydraulics International Sales OfficesParker Hannifin Corporation Hydraulic Valve Division 520 Ternes Avenue Elyria, Ohio 44035 USA Tel: 440-366-5200Fax: 440-366-5253/hydraulicvalve©2010 Parker Hannifin Corporation, all rights reservedBulletin HY14-2407/US,4M, 11/10, RRDNorth AmericaHydraulics Group Headquarters 6035 Parkland BoulevardCleveland, OH 44124-4141 USA Tel:216-896-3000Fax:216-896-4031Parker Hannifin Canada Division 160 Chisholm Drive Milton Ontario, Canada L9T 3G9Tel:905-693-3000Fax:905-876-1958MexicoParker Hannifin de México Industrial Hydraulic Sales Eje Uno Norte No. 100Parque Industrial Toluca 2000Toluca, Edo. de Mexico CP 50100Tel:52 72 2275 4200Fax:52 72 2279 9308Parker Hannifin de México Mobile Hydraulic SalesVia de FFCC a Matamoraos 730Apodaca, NL CP de Mexico 66600Tel:52 81 8156 6000Fax:52 81 8156 6068EuropeHydraulics Group Headquarters La Tuilière 61163 Etoy -Switzerland Tel:41 21 821 8500Fax:41 21 821 8580South AfricaParker Hannifin Africa Pty Ltd P.O. Box 1153ZA-Kempton Park 1620,Republic of South Africa Tel:27 11 961 0700Fax:27 11 392 7213Mobile SalesMobile Sales Organization and Global Sales850 Arthur AvenueElk Grove Village, IL 60007 USA Tel: 847-258-6200Fax: 847-258-6299Industrial SalesCentral Region 1042 Maple Avenue Unit 331Lisle, IL 60532 USA Tel:630-964-0796Great Lakes Region 6035 Parkland BoulevardCleveland, OH 44124-4141 USA Tel:216-896-2740Fax:866-498-7507Gulf Region20002 Standing Cypress Drive Spring, TX 77379 USA Tel:817-473-4431Fax:888-227-9454Southwest Region 700 S. 4th AvenueMansfield, TX 76063 USA Tel:817-473-4431Fax:888-227-9454Mid Atlantic & Southeast Regions1225 Old Alpharetta Rd Suite 290Alpharetta, GA 30005 USA Tel:770-619-9767Fax:770-619-9806Midwest Region 8145 Lewis RoadMinneapolis, MN 55427 USA Tel:763-513-3535Fax:763-544-3418Northeast Region P.O. Box 396Pine Brook, NJ 07058 USA Tel:973-227-2565Fax:973-227-2467Northwest Region6458 North Basin Avenue Portland, OR 97217 USA Tel:503-283-1020Fax:866-611-7308Pacific Region 8460 Kass DriveBuena Park, CA 90621 USA Tel:714-228-2509Fax:714-228-2511Asia PacificParker Hannifin Shanghai Ltd.280 Yunqiao Road,Jin Qiao Export Processing Zone Shanghai 201206, China Tel: 86 21 2899 5000Fax: 86 21 6445 9717Parker Hannifin Hong Kong Ltd.8/F, Kin Yip Plaza 9 Cheung Yee StreetCheung Sha Wan, Hong Kong Tel: 852 2428 8008Fax: 852 2480 4256Parker Hannifin Korea Ltd.9F KAMCO Yangjae Tower949-3 Dogok1-dong, Gangnam-gu Seoul, 135-860, Korea Tel: 82 2 559 0400Fax: 82 2 556 8187Parker Hannifin India Pvt Ltd.Plot No. EL-26, MIDC,TTC Industrial AreaMahape, Navi Mumbai, 400 709, India Tel: 91 22 6513 7081Fax: 91 22 2768 6841Parker Hannifin Australia Parker Hannifin Pty Ltd.9 Carrington RoadCastle Hill, NSW 2154, Australia Tel: 612 9634 7777Fax: 612 9842 5111Latin AmericaParker Hannifin Ind. e Com. Ltda Hydraulics DivisionAv. Frederico Ritter, 110094930-000 Cachoeirinha RS, Brazil Tel: 55 51 3470 6090Fax: 55 51 3470 9281Parker Hannifin Argentina S.A.I.C.Stephenson 27111667-Tortuguitas-Malvinas Argentinas Pcia. de Buenos Aires, Argentina Tel: 54 3327 44 4129Fax: 54 3327 44 4199Pan American Division7400 NW 19th Street, Suite A Miami, FL 33126 USA Tel: 305-470-8800Fax: 305-470-8808。
General DescriptionThe DSH103, 3-way spool valves are used as low flow directional valves, pilot valves, or selector valves. They can be used in normally open or normally closed applications.OperationIn the de-energized mode, the spool is positioned by spring force. The solenoid, when energized, directly shifts the spool against the spring, thus changing the flow path through the valve.Features•High flow capacity with reduced space requirements •Standard valve bodies and common cavities•One-piece encapsulated coil with minimal amperage draw •Manual overrides, seal variations and other options available •No dynamic seals •Variety of coil terminationsConstructionWire Class “H” for all voltages A.C. RectifiersIntegral full wave bridgeResponse Time(Dependent on flow and pressure)50 ms to 150 msVoltageWattsAmps10 VDC 20 1.4512 VDC 20 1.1724 VDC 200.57120 VAC 20.144240 VAC20.079Solenoid Coil SpecificationsRated FlowDSH103N.O.11.3 LPM (3.0 GPM)N.C.18.8 LPM (5.0 GPM)Selector 13.1 LPM (3.5 GPM)DSH103B N.C.18.8 LPM (5.0 GPM)Selector 15.0 LPM (4.0 GPM)DSH103N N.O.22.5 LPM (6.0 GPM)Selector 22.5 LPM (6.0 GPM)Maximum Inlet 345 Bar (5000 PSI) - SteelPressure 210 Bar (3000 PSI) - Aluminum Leakage160 cc/min. (10 cu. in./min.)maximum at 345 Bar (5000 PSI)Minimum90% of rated voltage Operating Voltage at 345 Bar (5000 PSI)Operating Temp.-40°C to +93.3°C (Nitrile)Range (Ambient)(-40°F to +200°F)-31.7°C to +121.1°C (Fluorocarbon)(-25°F to +250°F)Cartridge Material All parts steel. All operating parts hardened steel.Body Material Steel or Aluminum Filtration ISO Code 16/13,SAE Class 4 or better Mounting No restrictionsCavityCommon Cavity No. C10-3Specifications(2)(3)(2)(3)(2)(3)DSH103NDSH103BSeries DSH103 *Inch equivalents for millimeter dimensions are shown in (**)Dimensions22.9 (.90)NormalOperation27.4 (1.08)CoilOverriddenPush and TwistManual Override54.0(2.13)31.8(1.25)66.7(2.63)15.9(.63)1Hex.65 N.m.(575 In.-Lbs.)Torque″Cartridge OnlyIn BodySeries DSH103Ordering Information。
D4S UK.indd 24.01.226Seat valves series D4S are designed for directional control functions. A large variety of poppets, springs and covers – including shuttle valves, stroke limiters, solenoid valves (VV01) and position control – allow to design indi-vidual hydraulic solutions for nominal flow up to 600 l/min.A complete program of 2/2-way seat valves is offered under Parker brand:subplate mounted valves series D4S chapter 6 SAE flange valves series D5S chapter 9slip-in cartridges series CAR on request Features• Subplate mounting according to ISO 5781• Leak-free seat valve design • Numerous pilot options • 6 poppet types • D4S03 - NG10 D4S06 - NG25 D4S10 - NG32D4S10-9DCSeries D4SD4S UK.indd 24.01.2264) To be used in combination with rectifier plugs at 120 VAC/230 VAC powersupply.Ordering CodeExamples see end of chapterD4S9BSeries D4SD4S UK.indd 24.01.226Technical DataD4S pilot configurationSeries D4SD4S UK.indd 24.01.226Performance Curves / CartridgesD p/Q performance curvesLeakageSelection of CartridgesAll characteristic curves measured with HLP46 at 50 °C.Series D4SD4S UK.indd 24.01.226DimensionsSeries D4SD4S UK.indd 24.01.226Dimensions D4S with VV01Dimensions() Dimensions in brackets are for version VV01with shuttle valve code DB or DD.Dimensions D4S with shuttle valvevent valve VV01cap shuttle valve(pilot oil from A and B)body version series D4SCode CB or CDvent valve VV01cap shuttle valve 1)body version series D4SCode DB or DDD4S..-....../1090Solenoid energized:D4S blockedSolenoid de-energized:Flow from A-B or B-Awith manual override without manual overrideD4S..-......11/12Solenoid energized:Flow from A-B or B-A Solenoid de-energized:D4S blockedwith manual override without manual override1) Pilot oil from A and B, from B to A check valve function.Series D4SD4S UK.indd 24.01.226Dimensions D4S stroke limiterDimensionsU S 0V U strokePosition control by proximity switch (incl. amplifier)Valve open: proximity switch activated.This proximityswitch is pressure proof and has no wearing parts.Note Position control for D4S06 and D4S10 only.Note:Stroke limiter not for use with D4S03, vent valve VV01, shuttle valve and positon control.Position control as per IEC 61076-2-101 (M12x1)M12 pin assignment1 Us 10...30 V2 not connected3 0 V4Out A: normally openPlease order plug M12 x 1 separately. Straight plug recommended – no defined position possible for angled plug.Series D4SD4S UK.indd 24.01.226Ordering Code Explanation (Examples)D4S direct operatedD4S with VV01Series D4SD4S UK.indd 24.01.226Ordering Code Explanation (Examples)D4S with VV01D4S with shuttle valveSeries D4SD4S UK.indd 24.01.226D4S..-.113A.EA (with position control)Pilot oil X = externalD4S..-.21-3A.-EA (with position control)Pilot oil X = internal from A Drain Y1 = external out of the capD4S..-.12-3A.-EC EE }with position controland VV01Pilot oil X = externalDrain Y1 = external out of the capD4S..-.22-3A.-EC EE }with position controland VV01Ordering Code Explanation (Examples)D4S with position controlD4S with stroke limiter。
Bulletin HY17-8814-M1/UKSpare Parts List Series F130CF/F130CP Effective date: August 22, 2016Supersedes: November 20, 2015Directional Control Valves Series F130CF/F130CPBulletin HY17-8814-M1/UKSpare Parts ListConversion factors1 kg = 2.2046 lb 1 N = 0.22481 lbf 1 Nm = 0.10197 kpm 1 bar = 14.504 psi 1 l = 0.21997 UK gallon 1 l = 0.26417 US gallon 1 cm 3 = 0.061024 in 31 m = 3.2808 feet 1 mm= 0.03937 in1°C = (9/5xC°+32)°FThis list of spare parts is designed to give you a good idea of the components included in the product range for valves. T o see precisely which component is used for a specifi c product, you will need to look at the customer specifi cation for the product in question. The customer specifi cation contains a number of entries, and for each entry, a code pressure or fl ow is specifi ed with a code or a number. T o help you fi nd your way around, this list of spare parts contains r eferences to these entries and codes.Codes on the image page of the list of spare parts usually appear in bold and enclosed in a border. The table page contains available spare part sets. The ordering code is the product code that appears in the Part column.The spare part to be used is determined by the fi rst two columns, which c ontain the entry and the code from the customer specifi cation. If these c olumns are empty, the spare part set is valid regardless of the selected code, unless indicated otherwiseThe symbols in the frame below are used in this Spare Parts List to help you fi nd the right tools, the right tor-ques, suitable grease etc.Technical index description1 = Item pos. no. 1.1(2x) = Item pos. no. 1, contains 2 pieces in the kit 1[2] = Item pos. no. 2 already mounted on item pos. no. 1 at delivery.1[2](2x) = Item pos. no. 1 (see above) contains 2 pieces in the kit.Directional Control Valves Series F130CF/F130CPBulletin HY17-8814-M1/UKContentsF130CF-06-SE10-999A 1234560624-224707-005DesignationCustomer ordered markingSerial numberValve serial numbers consist of three groups of digits The fi rst group shows year and week of manufacture:In this example, 0624 means week 24 of 2006The remaining digits are for internal use within ParkerThis spare parts list is valid for F130 generation 2 only. See product designation on the name plate. For spare parts to generation 1 see product information No HY17-8801-M1/UKGeneration 2 has designation in format as shown below:F130CF-XX-XXXX-XXX F130CF-XX-XXXX-XXXX F130CP-XX-XXXX-XXX F130CP-XX-XXXX-XXXXNotice ! Some valves hasn't any designation code stamped. Some valves has the serial number and designation code text line in opposite order than the example above.Name plateList of contentsConventional Inlet Options IPS, PB, L, B, P1B, P2B, T2B, Y , CUI, CUI2, LSI ............................4Inlet Options IUPS, PB, Y , N3, X3, BEN ..................................................................6Mid-Inlet Options MIC2 ..................................................................................................8C3, C5, PS, PB, Y ........................................................................10Spool ActuatorsC, B3, SI2, SI2, A13, A20, A40, A67, A323Lever brackets LMA,LMB, LM+A92,LJA,LJB,LJ+A92,LJ+A208,LU,LU .12ACE ..............................................................................................14ACP ..............................................................................................16EC1, EC2, EC3, EC4, ECS1, ECS2, ECS3, ECS4, A, D ............18ECH1, ECH2, A, D .......................................................................20PC30, PC40,A211,A350 ..............................................................22Spool Section OptionsEA, EB, N, X, MS, PA, X2, N2, Y2 ................................................24Outlet OptionsUSP , US, R35, S, ST, YS, T3B, T1B, TP , TPB, TB, TPC, PT , LD ...26 Tie rods, Bracket, Intersection seals ...........................................28Appendix A: Warnings .....................................................................30Appendix C: Assembly Instructions. Tools ...................................31Appendix D: Phased outPC3, PC4; C + SI, PT (35)Directional Control Valves Series F130CF/F130CPBulletin HY17-8814-M1/UKPS, PB, L, B, P1B, P2B, T2B, Y, CUI, CUI2, LSIConventional Inlet Options IDirectional Control ValvesBulletin HY17-8814-M1/UKDirectional Control Valves Bulletin HY17-8814-M1/UKSeries F130CF/F130CP Inlet Options IUPS, PB, Y, N3, X3, BENInlet with pump unloadingDirectional Control Valves Bulletin HY17-8814-M1/UKSeries F130CF/F130CP Inlet Options IUSee Customer Specifi cationCode Pos Part Description Remarks / ItemsN3239120199902Check valve9 [6, 7, 8]X3239120199903Plug8, 9BEN229120199904Solenoid valve14 [15, 17]BEN + 1222 + 056760414CCP012A, Coil, 12 VDC16BEN + 2422 + 056760415CCP024A, Coil, 24 VDC16IU159120199905Basic kit11, 13 [12](2x), 18, 20, 21 IU156760017Plug kit M6x1212(2x), 13(2x)IU15393000K067Counter pressure valve22, 23, 24, 25, 27IU159120199907Seal kit8, 12(2x), 20, 24IU15-Plug VSTI1/4EDCF27Directional Control Valves Bulletin HY17-8814-M1/UKSeries F130CF/F130CP Mid-Inlet Options MIC2Directional Control Valves Bulletin HY17-8814-M1/UKSeries F130CF/F130CP Mid-Inlet Options MISee Customer Specifi cationCode Pos Part Description Remarks / ItemsC293-Plug VSTI1EDCF1C293-Plug 16HP5ON-S1C293398000K061Plug (O-ring) 1/2", BSP3C293-Plug VSTI3/4EDCF11C293-Plug 12HP5ON-S11C2936760412Plug kit18 [13(2x), 14, 15, 16, 17]C293301000K831Seal kit13(2x), 14, 15, 16, 17Directional Control ValvesSeries F130CF/F130CP Bulletin HY17-8814-M1/UKC3, C5, PS, PB, YMid-Inlet Options MIa) See page 4a)C3/C5Mid-Inlet Options MISee Customer Specifi cationCode Pos Part Description Remarks / ItemsC3, C593-Plug VSTI1EDCF1C3, C593-Plug 16HP5ON-S1C3, C593-Plug VSTI3/4EDCF13C3, C593-Plug 12HP5ON-S13C393398000K061Plug (O-ring) 1/2", BSP3C3, C593301000K833Blocking plug C3, C58 [5(2x), 6, 7], 10C3, C593-Plug VSTI1/4EDCF10C3, C593301000K835Seal kit5(2x), 6, 7, 10C5936760413Blocking plug, C522C393301000K804Conversion kit C33, 8 [5(2x), 6, 7], 10, 13, 19C593301000K807Conversion kit C5, (80 - 125) bar8 [5(2x), 6, 7], 10, 20, 22C593301000K808Conversion kit C5, (126 - 140) bar8 [5(2x), 6, 7], 10, 20, 22C593301000K809Conversion kit C5, (141 - 160) bar8 [5(2x), 6, 7], 10, 20, 22C593301000K810Conversion kit C5, (161 - 210) bar8 [5(2x), 6, 7], 10, 20, 22C593301000K805Conversion kit C5, (211 - 250) bar8 [5(2x), 6, 7], 10, 20, 22C593301000K811Conversion kit C5, (251 - 280) bar8 [5(2x), 6, 7], 10, 20, 22C593301000K812Conversion kit C5, (281 - 320) bar8 [5(2x), 6, 7], 10, 20, 22C593301000K813Conversion kit C5, (321 - 350) bar8 [5(2x), 6, 7], 10, 20, 22Spool ActuatorsC, B3, SI2, LMA, LMB, LJA, LJB, LU, LU2, A13, A20, A40, A67, A92, A208, A324Spool Actuators ACESpool ActuatorsSee Customer Specifi cationCode Pos Part Description Remarks / ItemsACE509120039065Cylinder kit, BSP15, 16, 17(2x), 18, 19, 20(2x) ACE509120099911Spring kit ACE 5 [4](2x), 7, 8, 9, 10, 11, 12, 13, 14ACE + 1250 + 0591********Solenoid valve, 12 VDC21,22,23,24,33(2x),34,35[31,32] ACE + 2450 + 0591********Solenoid valve, 24 VDC21,22,23,24,33(2x),34,35[31,32] ACE509120099913Spares kit for solenoid valve22, 23, 24, 31, 32, 33(2x), 35 ACE509120099912Seal kit, ACE 5 [4](2x), 15, 17(2x)ACE50-Connector, inlet (P6F-BEAA146)25ACE50-T ube, ø6, L=35 mm (P6T-PN06100)26ACE50-Connector, intermediate (P6F-BTS46)27ACE50-End plug (P6F-BVP46)28ACE50-T ube ø6, L = 89 mm (P6T-PN06100)29ACE506760420Conector kit for 4 sections30 [25(4x), 26(7x), 27(4x), 28, 29]Spool Actuators ACPSpool ActuatorsSee Customer Specifi cationCode Pos Part Description Remarks / ItemsACP + G50 + 049120039063Cylinder kit, BSP15, 16, 17(2x), 18, 19, 20(2x)ACP + U50 + 049120039064Cylinder kit, UNF15, 16, 17(2x), 18, 19, 20(2x)ACP509120099914Spring kit ACP 5 [4](2x), 7, 8, 9, 10, 11, 12, 13, 14, 21 ACP509120099912Seal kit, ACP 5 [4](2x), 15, 17(2x)EC1, EC2, EC3, EC4, ECS1, ECS2, ECS3, ECS4, A, DSpool ActuatorsEC1/EC2ECS1/ECS2A-sideEC1/EC2ECS1/ECS2B-sideSpool ActuatorsSee Customer Specifi cationCode Pos Part Description Remarks / Itemsa) + G50 + 046763137Cap kit EC, A-side, BSP9(2x), 11, 12(2x), 20 [4, 5, 6]a) + U50 + 046763138Cap kit EC, A-side, UNF9(2x), 11, 12(2x), 20 [4, 5, 6]a) + G50 + 046763134Cap kit EC, B-side, BSP9(2x), 11, 13(2x), 19 [4, 5, 6]a) + U50 + 046763135Cap kit EC, B-side, UNF9(2x), 11, 13(2x), 19 [4, 5, 6]b) + G50 + 046763700Cap kit EC, A-side, BSP9(2x), 11, 12(2x), 16 [4, 5, 6]b) + U50 + 046763698Cap kit EC, A-side, UNF9(2x), 11, 12(2x), 16 [4, 5, 6]b) + G50 + 046763701Cap kit EC, B-side, BSP9(2x), 11, 13(2x), 15 [4, 5, 6]b) + U50 + 046763699Cap kit EC, B-side, UNF9(2x), 11, 13(2x), 15 [4, 5, 6]a), b) + G50 + 04301000K843Seal kit EC*, BSP4(2x), 5(2x), 9(4x), 11(2x)a), b) + U50 + 04301000K822Seal kit EC*, UNF4(2x), 5(2x), 9(4x), 11(2x)EC*1,EC*350301000K844Spring pack (5 - 15) bar14EC*2,EC*450301000K845Spring pack (7 - 25) bar14A34050S6763546Spring pack (5 - 20) bar14a) + 12 + A50 + 05+ 566763059Solenoid valve, PS25, 12 VDC28(2x), 29 [25, 26, 27]; No c), Amp. conn.a) + 24 + A50 + 05+ 566763060Solenoid valve, PS25, 24 VDC28(2x), 29 [25, 26, 27]; No c), Amp. conn.a) + 12 + D50 + 05+ 566763061Solenoid valve, PS25, 12 VDC28(2x), 32 [25, 26, 27]; No c), Deutsch c.a) + 24 + D50 + 05+ 566763062Solenoid valve, PS25, 24 VDC28(2x), 32 [25, 26, 27]; No c), Deutsch c.a) + 12 + A50 + 05+ 566763328Solenoid valve, PS25MO, 12 VDC28(2x), 29 [25, 26, 27]; With c), Amp. conn.a) + 24 + A50 + 05+ 566763327Solenoid valve, PS25MO, 24 VDC28(2x), 29 [25, 26, 27]; With c), Amp. conn.a)506760507Seal kit PS2525(5x), 26(5x), 27(5x)O + a)55A/B + 50398000K604Pilot restriction "O", Ø1.2 mm18(5x) without damping)N + a)55A/B + 50398000K602Pilot restriction "N", Ø0.9 mm18(5x) Normal dampingH + a)55A/B + 50398000K601Pilot restriction "H", Ø0.6 mm18(5x) Hard dampingb) + 12 + A50 + 05+ 56393000M012Solenoid valve, PVC25, 12 VDC7(2x), 8 [1, 2, 3]; With c), Amp. connection b) + 24 + A50 + 05+ 56393000M024Solenoid valve, PVC25, 24 VDC7(2x), 8 [1, 2, 3]; With c), Amp. connection b) + 12 + D50 + 05+ 56393000D012Solenoid valve, PVC25, 12 VDC7(2x), 31 [1, 2, 3]; With c), Deutsch conn.b) + 24 + D50 + 05+ 56393000D024Solenoid valve, PVC25, 24 VDC7(2x), 31 [1, 2, 3]; With c), Deutsch conn.b) + 12 + A50 + 05+ 56393000N012Solenoid valve, PVC25, 12 VDC7(2x), 8 [1, 2, 3]; No c), Amp. connection b) + 24 + A50 + 05+ 56393000N024Solenoid valve, PVC25, 24 VDC7(2x), 8 [1, 2, 3]; No c), Amp. connection b)50393000K813Seal kit PVC251, 2, 3O + b)55A/B + 506760086Pilot restriction "O", Ø1.2 mm17(5x) without damping (5 dots)N + b)55A/B + 506760083Pilot restriction "N", Ø0.9 mm17(5x) Normal damping (10 dots)H + b)55A/B + 506760080Pilot restriction "H", Ø0.6 mm17(5x) Hard damping (1 dot)-Plug VSTI1/8EDCF4-Plug 4HP5ON-S4a) EC1, ECS1, EC2, ECS2 (PS25); b) EC3, ECS3, EC4, ECS4 (PVC25); c) Man. override, air bleed.Spool ActuatorsECH1, ECH2, A, DB-sideSpool ActuatorsSee Customer Specifi cationCode Pos Part Description Remarks / Itemsa) + G50 + 046763548Cap kit ECH, A-side, BSP9(2x), 11, 12(2x), 20 [4, 5, 6]a) + U50 + 046763549Cap kit ECH, A-side, UNF9(2x), 11, 12(2x), 20 [4, 5, 6]a) + G50 + 046763134Cap kit EC, B-side, BSP9(2x), 11, 13(2x), 19 [4, 5, 6]a) + U50 + 046763135Cap kit EC, B-side, UNF9(2x), 11, 13(2x), 19 [4, 5, 6]a) + G50 + 046763550Seal kit EC*, BSP4(2x), 5(2x), 9(4x), 11(2x)a) + U50 + 046763551Seal kit EC*, UNF4(2x), 5(2x), 9(4x), 11(2x)ECH1,ECH250301000K844Spring pack (5 - 15) bar14A34050S6763546Spring pack (5 - 20) bar14a) + 12 + A50 + 05+ 566763059Solenoid valve, PS25, 12 VDC28(2x), 29 [25, 26, 27]; No c), Amp. conn.a) + 24 + A50 + 05+ 566763060Solenoid valve, PS25, 24 VDC28(2x), 29 [25, 26, 27]; No c), Amp. conn.a) + 12 + D50 + 05+ 566763061Solenoid valve, PS25, 12 VDC28(2x), 32 [25, 26, 27]; No c), Deutsch c.a) + 24 + D50 + 05+ 566763062Solenoid valve, PS25, 24 VDC28(2x), 32 [25, 26, 27]; No c), Deutsch c.a) + 12 + A50 + 05+ 566763328Solenoid valve, PS25MO, 12 VDC28(2x), 29 [25, 26, 27]; With c), Amp. conn.a) + 24 + A50 + 05+ 566763327Solenoid valve, PS25MO, 24 VDC28(2x), 29 [25, 26, 27]; With c), Amp. conn.a)506760507Seal kit PS2525(5x), 26(5x), 27(5x)O + a)55A/B + 50398000K604Pilot restriction "O", Ø1.2 mm18(5x) without damping)N + a)55A/B + 50398000K602Pilot restriction "N", Ø0.9 mm18(5x) Normal dampingH + a)55A/B + 50398000K601Pilot restriction "H", Ø0.6 mm18(5x) Hard dampingG04-Plug VSTI1/8EDCF4U04-Plug 4HP5ON-S4a) ECH1, ECH2 (PS25); c) Man. override, air bleed.PC30/PC40A21146B-sidePC3 is replaced by PC30 and PC4 is replaced by PC40from jan. 2012. These options are fully replaceable.Spool Actuators PC30, PC40,A211,A350Spool ActuatorsSee Customer Specifi cationCode Pos Part Description Remarks / Items PC30, PC40 + G50 + 046760397Cap kit PC30/40, A or B side, BSP11, 22(2x), 23PC30, PC40 + U50 + 046760399Cap kit PC30/40, A or B side, UNF11, 22(2x), 23PC30, PC40506763308Seal kit PC30, PC4011 (5x)A211 + G59 + 046760398Cap kit A211, A or B side, with5, 6, 11, 22(2x), 24, 30spool stroke limiter, BSPA211 + U59 + 046760400Cap kit A211, A or B side, with5, 6, 11, 22(2x), 24, 30spool stroke limiter, UNFA350 + G59 + 046763702Cap kit A350, A or B side, with11, 22(2x),31,32,33spool stroke limiter, BSPA211,A350596763307Seal kit A211,A3505(2x), 11(2x)PC3050301000K844Spring pack (5 - 15) bar14PC4050301000K845Spring pack (7 - 25) bar14A34050S6763546Spring pack (5 - 20) bar14Spool Section OptionsEA, EB, N, X, MS, PA, X2, N2, Y2Outlet OptionsUSP, US, R35, S, ST, YS, T3B, T1B, TP, TPB, TB, TPC, PT, LDTie rods, Bracket, Intersection sealsOutlet Options(12)Outlet OptionsSee Customer Specifi cationCode Pos Part Description Remarks / Items Brackets301000K866Bracket kit12(6x), 13(2x), 15(2x), 16(6x)Tie rods9120199921Tie rod kit, valve 1 spool section, 160 mm14(3x), 12(6x), 16(6x)Tie rods9120199922Tie rod kit, valve 2 spool sections, 213 mm14(3x), 12(6x), 16(6x)Tie rods9120199923Tie rod kit, valve 3 spool sections, 256 mm14(3x), 12(6x), 16(6x)Tie rods9120199924Tie rod kit, valve 4 spool sections, 309 mm14(3x), 12(6x), 16(6x)Tie rods9120199925Tie rod kit, valve 5 spool sections, 352 mm14(3x), 12(6x), 16(6x)Tie rods9120199926Tie rod kit, valve 6 spool sections, 405 mm14(3x), 12(6x), 16(6x)Tie rods9120199927Tie rod kit, valve 7 spool sections, 448 mm14(3x), 12(6x), 16(6x)Tie rods9120092347Tie rod kit, valve 8 spool sections, 501 mm14(3x), 12(6x), 16(6x)Tie rods6760532Tie rod kit, valve 9 spool sections, 544 mm14(3x), 12(6x), 16(6x)Tie rods6760533Tie rod kit, valve 10 spool sections, 597 mm14(3x), 12(6x), 16(6x)Tie rods9120199931Tie rod kit, valve 11 spool sections, 640 mm14(3x), 12(6x), 16(6x)Tie rods9120199932Tie rod kit, valve 12 spool sections, 688 mm14(3x), 12(6x), 16(6x)Standard301000K851Intersection seals NBR (Nitrile)7(3x), 8(2x), 9(3x), 10, 11(4x) A3008E301000K850Intersection seals FPM (Viton®)7(3x), 8(2x), 9(3x), 10, 11(4x)Appendix A: WarningsDirectional Control Valves Series F130CF/F130CPBulletin HY17-8814-M1/UKAppendix C: Assembly Instructions. ToolsPLD130 is delivered set to the max of its face value (e.g. Required pressure for a PLD130-161-210 can only be adjusted to a value <210).Adjusting to the required level should be done as shown in below instrictions.1. Loosen the lock nut one rev.Counter-clockwise2. Set required pressure value by turning the adjusting screw.3. Hold adjusting screw and fasten lock nut clockwise. Tightening torque 10 Nm.Directional Control Valves Series F130CF/F130CPBulletin HY17-8814-M1/UKAppendix C: Assembly Instructions. ToolsRemoval and mounting of scraper ring4, 51. Remove carefully the old scraper ring (not spring loaded) to avoid damaging of the lever bracket. Use as tool a screwdriver,a nippers or a small hook.2. Clear scraper ring groove and make sure there are no color or paint flakes remaining in the track.3 The scraper ring with associated surfaces in the lever bracket must be oiled.4. Push the new scraper ring in the lever brackets track.Directional Control Valves Series F130CF/F130CPBulletin HY17-8814-M1/UKAppendix C: Assembly Instructions. ToolsCap kits 6760398 (BSP) and 6760400 (UNF) can be installed on both A and B side of valve Measure shown below is valid if NO stroke limit is requiredCap used on the B (spring pack) side of valve.Cap used on the A (spool end) side of valve.Directional Control Valves Series F130CF/F130CPBulletin HY17-8814-M1/UKAppendix C: Assembly Instructions. Tools1. A special tool must be used to engage the manual override function of the solenoid! Use of other tools to attempt to engage or disengage the manual override may not work or may not work when intended.2. When using the manual override function, the solenoid has only on-off functionality and doesn’t operate proportionally as usual. This means, for example, that the solenoid may operate much faster than usual and the unexpected speed could cause crushing or other injuries.3. When using the manual override be certain that all operations of the application, regardless of speed, will not endanger persons or property nearby.4. As always, consult the operations manual for all specifications and functions of the valve. If there are questions contact MSDE.The PS25MO is equipped with a manual override pin in the connector. T o actuate the PS25MO a specific tool is needed since the tolerances of the pin is so small that it can be damaged or the pin sticks in actuated position.Please notify that it’s for fault searching only and shall be used as rarely as possible with common sense in mind. If manual override is used humans can be exposed for very dangerous situations. Please read the legal limits before using the manual override.Part number for override tool: 6763001.Directional Control Valves Series F130CF/F130CPBulletin HY17-8814-M1/UKPTAppendix D: Phased outE d . 2015-04-21Your local authorized Parker distributorEMEA Product Information CentreFree phone: 00 800 27 27 5374(from AT , BE, CH, CZ, DE, DK, EE, ES, FI, FR, IE, IL, IS, IT , LU, MT , NL, NO, PL, PT , RU, SE, SK, UK, ZA)US Product Information Centre Toll-free number: 1-800-27 27 537Parker WorldwideEurope, Middle East, AfricaAE – United Arab Emirates, DubaiTel: +971 4 8127100********************AT – Austria, Wiener Neustadt Tel: +43 (0)2622 23501-0*************************AT – Eastern Europe, Wiener NeustadtTel: +43 (0)2622 23501 900****************************AZ – Azerbaijan, Baku Tel: +994 50 22 33 458****************************BE/LU – Belgium, Nivelles Tel: +32 (0)67 280 900*************************BG – Bulgaria, So a Tel: +359 2 980 1344**************************BY – Belarus, Minsk Tel: +48 (0)22 573 24 00************************CH – Switzerland, Etoy Tel: +41 (0)21 821 87 00*****************************CZ – Czech Republic, Klecany Tel: +420 284 083 111*******************************DE – Germany, Kaarst Tel: +49 (0)2131 4016 0*************************DK – Denmark, Ballerup Tel: +45 43 56 04 00*************************ES – Spain, Madrid Tel: +34 902 330 001***********************FI – Finland, Vantaa Tel: +358 (0)20 753 2500parker. ****************FR – France, Contamine s/Arve Tel: +33 (0)4 50 25 80 25************************GR – Greece, Athens Tel: +30 210 933 6450************************HU – Hungary, Budaoers Tel: +36 23 885 470*************************IE – Ireland, Dublin Tel: +353 (0)1 466 6370*************************IT – Italy, Corsico (MI)Tel: +39 02 45 19 21***********************KZ – Kazakhstan, Almaty Tel: +7 7273 561 000****************************NL – The Netherlands, Oldenzaal Tel: +31 (0)541 585 000********************NO – Norway, Asker Tel: +47 66 75 34 00************************PL – Poland, Warsaw Tel: +48 (0)22 573 24 00************************PT – Portugal, Leca da Palmeira Tel: +351 22 999 7360**************************RO – Romania, Bucharest Tel: +40 21 252 1382*************************RU – Russia, Moscow Tel: +7 495 645-2156************************SE – Sweden, Spånga Tel: +46 (0)8 59 79 50 00************************SK – Slovakia, Banská Bystrica Tel: +421 484 162 252**************************SL – Slovenia, Novo Mesto Tel: +386 7 337 6650**************************TR – Turkey, Istanbul Tel: +90 216 4997081************************UA – Ukraine, Kiev Tel: +48 (0)22 573 24 00************************UK – United Kingdom, Warwick Tel: +44 (0)1926 317 878********************ZA – South Africa, Kempton Park Tel: +27 (0)11 961 0700*****************************North AmericaCA – Canada, Milton, Ontario Tel: +1 905 693 3000US – USA, Cleveland (industrial)Tel: +1 216 896 3000US – USA, Elk Grove Village (mobile)Tel: +1 847 258 6200Asia Pacifi cAU – Australia, Castle Hill Tel: +61 (0)2-9634 7777CN – China, Shanghai Tel: +86 21 2899 5000HK – Hong Kong Tel: +852 2428 8008ID – Indonesia, Tangerang Tel: +62 21 7588 1906IN – India, MumbaiTel: +91 22 6513 7081-85JP – Japan, Fujisawa Tel: +81 (0)4 6635 3050KR – South Korea, Seoul Tel: +82 2 559 0400MY – Malaysia, Shah Alam Tel: +60 3 7849 0800NZ – New Zealand, Mt Wellington Tel: +64 9 574 1744SG – Singapore Tel: +65 6887 6300TH – Thailand, Bangkok Tel: +662 186 7000TW – Taiwan, New Taipei City Tel: +886 2 2298 8987VN – Vietnam, Ho Chi Minh City Tel: +84 8 3999 1600South AmericaAR – Argentina, Buenos Aires Tel: +54 3327 44 4129BR – Brazil, Cachoeirinha RS Tel: +55 51 3470 9144CL – Chile, Santiago Tel: +56 2 623 1216MX – Mexico, Toluca Tel: +52 72 2275 4200© 2015 Parker Hanni n Corporation. All rights reserved.。
D_FC EtherCAT UK.indd 27.07.223-75Parker Hannifin Corporation3IntroductionThe new proportional valves with position feedback series D*FC (direct operated) and D*1FC (pilot operated) with EtherCAT interface fulfill the requirements of modern communication between valve and main control. Due to high data transmission speed and short cycle times, also demanding control functions can be realized within the fieldbus system.The valve is actuated and monitored by the EtherCAT interface. Actual value (spool position), temperature, op -erating hours and different error messages are available as diagnostic signals. The valve parameters are factory set and can be adapted with the Parker ProPxD software via the parametrizing interface.In addition to the fieldbus communication, the valves pro -vide the range of functions of the standard version includ-ing analogue command signal and diagnostic spare stroke. Thus they can be operated independent of the fieldbus control, particularly during commissioning and maintenance.The option with EtherCAT is available for the series: • D1FC, D3FC• D31FC, D41FC, D91FC, D111FCTechnical DataFeatures EtherCAT interface• EtherCAT interface, 2x M12x1 connector 4-Pin (Ether -CAT In and EtherCAT Out)• Progressive flow characteristics for sensitive adjust -ment• Low hysteresis •High dynamics • High flow capacity• Onboard electronicsD1FC with EtherCATDirect and Pilot Operated Prop. DC Valve Series D*FC and D*1FC with EtherCATD_FC EtherCAT UK.indd 27.07.223-76Catalogue MSG11-3500/UKParker Hannifin Corporation3Ordering CodeHigh dynamicsCF DC N09Direct Operated Proportional DC ValveCode Size 1NG06 / CETOP 033NG10 / CETOP 05DC valveSizeCode Size3NG10 / CETOP 054NG16 / CETOP 079NG25 / CETOP 0811NG32 / CETOP 10CF 1DCPilot Operated Proportional DC ValveN00DC valveSpool position on power downSpool typeDesign series(not required for ordering)SealsSizeDrain port Y(plugged)Proportional control EtherCAT interfaceSee ordering code for valve series without EtherCATNG06 pilot valve Function FlowPilot connection EtherCAT interfaceSpool position on power downDesign series(not required for ordering)Seals Proportional control Integrated electronics with positionfeedbackSee ordering code for valve series without EtherCATPlease order connector separately, see chapter 3 accessories.Parametrizing cable OBE ® RS232, item no. 40982923Spool/body design3Direct and Pilot Operated Prop. DC Valve Series D*FC and D*1FC with EtherCATD_FC EtherCAT UK.indd 27.07.223-77Catalogue MSG11-3500/UKParker Hannifin Corporation3Block Diagram / DimensionsBlock diagramDimensions D1FC with EtherCAT。
Bulletin 2531-M10/USAService BulletinSeries D1VC, D1VD, Hydraulicsand D1VGEffective: March 23, 19982531-M10.pm6, sm, jjFAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONALINJURY AND PROPERTY DAMAGE.This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users having technical expertise. It is important that you analyze all aspects of your application and review the information concerning the product or system in the current product catalog. Due to the variety of operating conditions and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance, safety and warning requirements of the application are met.The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by Parker Hannifin Corporation and its subsidiaries at any time without notice.WARNINGThe items described in this document are hereby offered for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. This offer and its acceptance are governed by the provisions stated in the "Offer of Sale".Copyright 1997, Parker Hannifin Corporation, All Rights ReservedOffer of SaleModel Code ...........................................................................................................................................................1Parts DataD1VC*B***, D1VD*B***....................................Cam Operated .......................................................................2D1VC*H***, D1VD*H***....................................Cam Operated .......................................................................3D1VG*B***.......................................................Cam Lever Operated..............................................................4D1VG*H***.......................................................Cam Lever Operated..............................................................5Spool Chart ...........................................................................................................................................................6Troubleshooting Guide .. (7)2531-M10.pm6, sm, jj1 Spool 6977012 Spool 6977024 Spool 6977048 Spool 6977089 Spool 180000482 Spool 130121581 Spool 13011682148A BP TA BP TA BP TA BP TA BP TA BP TA BP TABNote Reverse Operator LocationNote Reverse Operator Location9WarningBefore any circuit connection is broken, be sure to turn off all power and relieve system pressure. Lower all vertical loads and cylinders, lock any load which could produce pressure and discharge any accumulators. Plug and cap all lines and openings to prevent contamination from entering the system.Cleaning and Inspection1.Proper cleaning is a critical part of preventive maintenance in the use of directional control valves. All parts shouldbe cleaned with a solvent that is compatible with the system fluid. Compressed air may also work well when cleaning orifices and passage ways, but proper filtration must be employed to remove water and contamination.NOTE: Always make sure all parts have been cleaned before reassembling.2.Inspectiona.Inspect all passage ways for obstructions.b.Inspect all washers, push pins, plungers and pole faces for signs of wear and/or mushrooming. Inspect allsprings for signs of distortion. Replace parts as necessary.c.Look for nicks and burrs on the spool and bore lands. Nicks in these areas indicate likely contamination of thesystem fluid.3.If there are no signs of nicks or burrs on the spool and bore, check the spool clearance as follows:a.Lubricate the spool and bore with clean system fluid.b.Insert the spool back into the body and slowly move the spool back and forth. The spool should move freely. Ifthere is any sticking between the spool and the bore, remove the spool and repeat 2b.c.The spool clearance can also be checked by placing the valve body on end and inserting the spool. Gravity willpull the spool to the other end if there is no sticking.d.After several attempts have been made without resolution, replace the valve.TroubleshootingProblem: Valve spool fails to moveCause RecommendationRecommended flow exceeded Check maximum flow rate for appropriate spool by spool function. Recommended pressure exceeded Check maximum pressure rating for valve.Improper installation connections Check installation drawings.Contamination in system Disasemble, inspect, clean and flush.Improper assembly Check proper assembly. Refer to drawing for appropriate model. Valve has silted Disassemble and clean valve.Problem: Valve produces undesirable responseCause RecommendationRecommended flow exceeded Check maximum flow rate for appropriate spool by spool function. Recommended pressure exceeded Check maximum pressure rating for valve.Improper installation connections Check installation drawings.Contamination in system Disassemble, inspect, clean and flush.Improper assembly Check proper assembly. Refer to drawing for appropriate model. Improper fluid Check fluid recommendations.Recommended temperature exceededCheck maximum temperature recommendations.(indicated by fluid discoloration or spool tarnishing)2531-M10.pm6, sm, jjContents Series D1VW, B StyleOffer of SaleHydraulics Parker Hannifin Corporation Hydraulic Valve DivisionElyria, Ohio 44035 USA ContentsDirectional Control Valves Series D1VW, B Style Bulletin 2531-M10/USA 9NotesHydraulics Bulletin 2531-M10/USA,5M, 3/98, PHD Parker Hannifin Corporation Hydraulic Valve Division 520 Ternes Avenue Elyria, Ohio 44035 USA Tel:(440) 366-5200Fax:(440) 366-5253Web Site: /hydraulicvalve。
PARKER方向控制阀D1VA系列选购指南手册PARKER方向控制阀D1VA系列选购指南手册
派克D1VA系列气动方向控制阀的设计基于标准的 D1VW方向阀, 其主阀芯通过一大直径的辅助阀芯进行操控, 这样, 3 到 5 bar 的
很低压力便可实现操控。
派克经久考验的 D1VA 系列气动操控, 直动式方向控制阀规格
为 NG06 / CETOP 03 / NFPA D03, 能在有气压源的应用场合提供可
靠和有效的控制, 它们也可作为经济的防爆阀替用产品, 用于具有
危险性的环境。
市场:
工业领域
PARKER方向控制阀特点/优势:
结构紧凑, 经久考验的设计, 代表了我们在液压技术领域中的
长期经验
多种阀芯型式与阀芯位置选项能适应所有的液压系统
*的性价比特别是在有防爆标准要求的场合使用时
供货周期短无需库存
PARKER方向控制阀应用:
适用于一般的液压应用系统
技术规范:
D1VA系列是以标准的 D1VW 系列方向阀为基础设计制造的气动
操控方向控制阀。
其主阀芯通过一个大作用面积的辅助活塞予以推动, 这样就可以用 3 至 5 bar 的控制气压实现操控。
控制气压经
由端盖上的 G1/8 螺纹口接入。
美国PARKER派克气动方向控制阀性能特点
名义尺寸 NG06
驱动气动操控
安装形式板式安装
操作形式导向
重量(公斤) 1.3
系列类型方向控制阀
派克Parker派克手动式换向阀D3DLB009CN4J、D3DLB004NN4J、D3DLB001NN4J
派克PARKER单向阀CPOM6AAV、CPOM6DDV、FM6DDKV45
派克PARKER溢流阀R25R25S4SN、R25R25S4SN38、R32M07S4SN、R32M35S4SN
派克PARKER溢流阀RS10M25S4SN1JW、RS10M25S4SN9JW40、CPOM2AAV
派克PARKER减压阀VMY160H10V1P、VMY210L10V1P、
SVLD546P20N
派克PARKER溢流阀DSDA1002P07K、RS10M25S4SN1JW40、
RS10R25S4SN1JW
派克PARKER放大板PWD00A400、PWDXXA400、PQDXXAZ00
派克PARKER比例减压阀DWLC522P20B、DWEE527P20ELAF、DWLC525P15E
派克PARKER伺服阀BD15AAANB10、BD30AAENB25、BD10124
派克PARKER比例阀D31FHE02C1NB00、D31FHE01C4NE00、
D31FHE01A4NB00
PARKER方向控制阀D1VA系列选购指南手册
派克汉尼芬(Parker Hannifin Inc) 是运动及控制(Motion d control)元件和系统控制综合性公司,1918年由L?Parker先生建立,从1924年由汽车及其关联产品开始,企业进入液压气动工业。
1957年购买了Hannifin Inc的油缸和阀门制造部门,发展成现在名称的公司。
它在世界上拥有在44个内2000个以上的生产点,有48000名从业人员,年销售额达60亿美元,在世界上有7500个销售和经销网点,有40万客户和关系单位。
PARKER用各种液压气动产品组成约2600种以上的主机,其中汽车工业和航空工业占1100个以上。
该公司2023年到6月底的业绩,年销售额达64亿美元,营业利润为37577万美元。
近七年PARKER连续收买了(MdA)50家企业,仅近2年又收购了8个企业和事业单位。
2023年公司购买了生产产业车辆/农业机械液压元件的美国商业公司(Commercial Intertech)计出资3.6亿美元,并承担了该公司的负债1亿7千万美元。
2023年1月从美国生产汽车零件的着名公司Dand Corp手
中、购买了Grensen Hydraulics,该公司在许多州以及巴西都有生
产厂,主要生产汽车用、工程机械用液压泵/马达、油缸、液压控制阀、过滤器以及电子控制装置的制造和销售。
上述两个公司的买入,充实了工程机械、车辆用液压机械,使公司在驱动、控制领域方面
实现了成套供应。
Gresen在巴西工厂的购入,使南美市场的占有率
增加,同时可以降低成本。