CS5480应用笔记B0 V2
- 格式:doc
- 大小:122.50 KB
- 文档页数:3
User GuideWRT3200ACM MU-MIMOGigabit Wi-Fi RouterContentsProduct Overview (3)Front view (3)Back view (5)Avoid Overheating (7)Wall-Mounting Placement (7)Setting Up: Basics (10)Where to find more help (10)How to install your router (10)How to Use Linksys Smart Wi-Fi (13)How to connect to Linksys Smart Wi-Fi (13)Network Map (14)Guest Access (14)Parental Controls (15)Media Prioritization (15)Speed Test (16)External Storage (16)Connectivity (17)Troubleshooting (17)Wireless (18)Security (18)Troubleshooting (19)Your router was not successfully set up (19)Your Internet cable is not plugged in message (19)Cannot access your router message (20)After setup (22)Specifications (24)Linksys WRT3200ACM (24)Environmental (24)Product Overview Front viewFront panel(1) Power indicator—(White) The icon LED is solid white while the router is powered on. It will blink when the router goes through its self-diagnostic mode during every boot-up.(2) Internet Indicator—(White/Amber) The Internet LED is solid white when connected to the Internet. It blinks white while the router works to establish a connection. A solid amber LED indicates the connection is down due to configuration issues. Amber blinking indicates that the connection is down due to hardware issues.(3) 2.4 GHz Indicator—(White) The Wireless LED is solid white when one or more clients are connected to the 2.4 GHz network. If the LED is blinking white, the router is sending or receiving data over the 2.4 GHz network.(4) 5 GHz Indicator—(White) The Wireless LED is solid white when one or more clients are connected to the 5GHz network. If the LED is blinking white, the router is sending or receiving data over the 5 GHz network.(5) eSATA Indicator—(White) When off, the USB/eSATA port is off or a USB device is connected. The LED is solid white when an eSATA device is connected. A blinking white LED indicates activity through the eSATA port.(6) USB1 Indicator—(White) When off, the USB /eSATA port is off or an eSATA device is connected. The LED is solid white when a USB device is connected. A blinking white LED indicates activity on the port.(7) USB2 Primary Indicator—(White) When off, the USB 3.0 port is off. The LED is solid white when a USB device is connected. A blinking white indicates activity on the port.(8) USB2 Secondary Indicator—(White) When off, a USB 1.0 or USB 2.0 device is connected. A solid white LED indicates a USB 3.0 device is connected.(9) ETHERNET 1 through 4 (Primary)—(White) These numbered LEDs correspond with the numbered ports on the router’s back panel. If the white LED is solid, the router is connected to a device through that port. A flashing white LED indicates network activity over that port.(10) ETHERNET 1 through 4 (Secondary)—(White) If the white LED is off, the router is successfully connected to a device through that port at 10/100 Mbps. A solid white LED indicates that the router is successfully connected to a device at 1000 Mbps.(11) WPS Indicator—(White/Amber) The LED blinks slowly for up to two minutes during Wi-Fi Protected Setup. It will be solid white for five seconds to indicate a successful connection. The LED blinks amber if the Wi-Fi Protected Setup process fails. Make sure the client device supports Wi-Fi Protected Setup. Wait until the LED is off, and then try again. The router supports one session at a time.Back view(1) Adjustable antennas—This router ships with four adjustable external antennas that should be connected to the router before powering it on. To connect the antennas, twist the antenna connector clockwise onto the antenna port on the router.Note—For best performance, position the side antennas vertically as shown in the picture on the left.(2) Wi-Fi Protected Setup™ button—Press to configure wireless security on Wi-Fi Protected Setup-enabled network devices.(3) Ethernet ports—Connect Ethernet cables to these blue gigabit (10/100/1000) ports, and to wired devices on your network.Note—For best performance, use CAT5e or higher rated cables on the Ethernet ports.(4) Internet port—Connect an Ethernet cable to this yellow gigabit (10/100/1000) port, and to a broadband Internet cable/DSL or fiber modem.Note—For best performance, use CAT5e or higher rated cables on the Internet port.(5) USB 3.0 port—Connect and share a USB drive on your network or on the Internet.(6) USB 2.0/eSATA combo port—Connect and share a USB or eSATA drive on your network or on the Internet. You can also connect a USB printer and share it across your network.(7) Reset button—Press and hold for 10 seconds (until the power LED starts flashing) to reset the router to factory settings. You can also restore the factory settings using Linksys Smart Wi-Fi on the Internet or mobile app.(8) Power port—Connect the included AC power adapter.(9) Power button (EU models only)—Press to turn on the router.Avoid OverheatingWall-Mounting PlacementThe router has wall-mount slots on the bottom of each foot for flexibility in mounting the router on the wall. The distance between the slots on the short side is 104 mm. The distance between the slots on the longer side is 210 mm. Two screws are needed to mount the router.Note—Linksys is not responsible for damages incurred by unsecured wall-mounting hardware. Mounting Instructions1.Determine where you want to mount the router and which side you should use to mount it.Make sure that the wall you use is smooth, flat, dry, and sturdy. Make sure the location is within reach of an electrical outlet.2.Before drilling holes, choose the template (short side or long side) that fits yourinstallation. Drill the holes using the correct template.3.Insert a screw into each hole and leave 4 mm of its head exposed.4.Position the router so the wall-mount slots line up with the two screws.5.Place the wall-mount slots over the screws and slide the router down until the screws fitsnugly into the wall-mount slots.Wall-Mounting TemplatePrint this page at 100% size.Place on the wall with desired router position and mark screw locations.Setting Up: BasicsWhere to find more helpIn addition to this user guide, you can find help at these locations:•/support/WRT3200ACM (documentation, downloads, FAQs, technical support, live chat, forums)•Linksys Smart Wi-Fi help (connect to Linksys Smart Wi-Fi, then click Help at the top of the screen)Note—Licenses and notices for third party software used in this product may be viewed on/en-us/license. Please contact /en-us/gplcodecenter for questions or GPL source code requests.How to install your router1.If replacing an existing router, disconnect that router first.2.Turn the antennas so they are positioned straight up and plug in your router to a powersource. European versions: press the power switch to | (on).3.Connect the Internet cable from your modem to the yellow Internet port on your router.Wait until the indicator light on your router is solid.4.Connect to the secure wireless name shown in the Quick Start Guide that came with yourrouter. (You can change the network name and password later.) If you need helpconnecting to the network refer to your device documentation on the provided CD.Note—You will not have Internet access until router setup is complete.5.Open a web browser to launch the Linksys Smart Wi-Fi Router setup instructions. If youdon’t see the instructions, type in the address bar.At the end of setup, follow the on-screen instructions to set up your Linksys Smart Wi-Fi account. Use Linksys Smart Wi-Fi to configure your router from any computer with an Internet connection. Manage your router’s settings:•Change your router’s name and password•Set up guest access•Configure parental controls•Connect devices to your network•Test your Internet connection speedNote—As part of Linksys Smart Wi-Fi account setup, you will be sent a verification e-mail. From your home network, click the link in the email to associate your router with the Linksys Smart Wi-Fi account.Tip—Print the next page, then record your router and account settings in the table as a reference. Store your notes in a safe place.2.4 GHz Network NameNetwork Password 5 GHz Network NameNetwork Password Router Password Guest Network NameGuest Network Password Linksys Smart Wi-Fi UsernameLinksys Smart Wi-Fi PasswordHow to Use Linksys Smart Wi-FiYou can configure your router from anywhere in the world by using Linksys Smart Wi-Fi, but you can also configure your router directly from your home network. Linksys Smart Wi-Fi may be available for your mobile device, as well. See your device’s app store for information.How to connect to Linksys Smart Wi-FiTo connect to Linksys Smart Wi-Fi:1.Open your computer’s web browser.2.Go to and log in to your account.If you can’t remember your password, click Forgot your password? and follow the on-screen instructions to recover it.Network MapLets you display and manage all network devices connected to your router. You can view devices on your main network and your guest network, or display information about each device.Guest AccessLets you configure and monitor a network that guests can use without accessing all of your network resources.Parental ControlsLets you block web sites and set Internet access times.Media PrioritizationLets you set which devices and applications have top priority for your network traffic.Speed TestLets you test your network’s Internet connection speed.External StorageLets you access an attached USB drive (not included) and set up file sharing, a media server, and FTP access.ConnectivityLets you configure basic and advanced network settings.TroubleshootingLets you diagnose problems with your router and check the status of the network.WirelessLets you configure your router’s wireless network. You can change the security mode, password, MAC filtering, and connect devices using Wi-Fi Protected Setup™.SecurityLets you configure your router’s wireless security. You can set up the firewall, VPN settings, and make custom settings for applications and games.TroubleshootingYou can find more help from our award-winning customer support at/support/WRT3200ACM.Your router was not successfully set upIf Linksys Smart Wi-Fi did not complete the setup, you can try the following:•Press and hold the Reset button on your router with a paperclip or pin until the LED starts blinking (about 10 seconds). Install the router again.•Temporarily disable your computer’s firewall (see the security software’s instructions for help). Install the router again.•If you have another computer, use that computer to install the router again. Your Internet cable is not plugged in messageIf you get a “Your Internet cable is not plugged in” message when trying to set up your router, follow these troubleshooting steps.•Make sure that an Ethernet or Internet cable (or a cable like the one supplied with your router) is securely connected to the yellow Internet port on the back of the router and to the appropriate port on your modem. This port on the modem is usually labeled Ethernet, but may be named Internet or WAN.•Make sure that your modem is connected to power and is turned on. If it has a power switch, make sure that it is set to the ON or l (as opposed to O) position.•If your Internet service is cable, verify that the cable modem’s CABLE port is connected to the coaxial cable provided by your ISP.•If your Internet service is DSL, make sure that the DSL phone line is connected to the modem’s DSL port.•If your computer was previously connected to your modem with a USB cable, disconnect the USB cable.•Install the router again.Cannot access your router messageTo access your router, you must be connected to your own network. If you currently have wireless Internet access, the problem may be that you have accidentally connected to a different wireless network.To fix the problem on Windows computers, do the following*:1.On your Windows desktop, click on the wireless icon in the system tray. A list of availablenetworks will appear.2.Click your own network name. Click Connect. In the example below, the computer wasconnected to another wireless network named wraith_5GHz. The wireless network name of the Linksys WRT3200ACM router, Damaged_Beez2.4 in this example, is shown selected.3.If you are prompted to enter a network key, type your password (Security Key) into theNetwork key and Confirm network key fields. Click Connect.4.Your computer connects to the network, and you should now be able to access the router. *Depending on your version of Windows, there could be some differences in wording or icons in these steps.To fix the problem on Mac computers, do the following:1.In the menu bar across the top of the screen, click the Wi-Fi icon. A list of wireless networkswill appear. Linksys Smart Wi-Fi has automatically assigned your network a name.2.In the example below, the computer was connected to another wireless network namedwraith_5GHz. The wireless network name of the Linksys WRT3200ACM router,Damaged_Beez2.4 in this example, is shown selected.3.Click the wireless network name of your Linksys WRT3200ACM router(Damaged_Beez2.4 in the example).4.Type your wireless network password (Security Key) into the Password field. Click OK. After setupThe Internet appears to be unavailableIf the Internet has difficulty communicating with your router, the problem may appear as a “Cannot find [Internet address]” message in your Web browser. If you know that the Internet address is correct, and if you’ve tried several valid Internet addresses with the same result, the message could mean that there’s a problem with your ISP or modem communicating with your router.Try the following:•Make sure that the network and power cables are securely connected.•Make sure that the power outlet that your router is connected to has power.•Reboot your router.•Contact your ISP and ask about outages in your area.The most common method of troubleshooting your router is to turn it off, then back on again. Your router can then reload its custom settings, and other devices (such as the modem) will be able to rediscover the router and communicate with it. This process is called rebooting.To reboot your router using the power cord, do the following:1.Disconnect the power cord from the router and the modem.2.Wait 10 seconds, and reconnect the power cord to the modem. Make sure it has power.3.Wait until the modem’s online indicator has stopped blinking (about two minutes). Reconnectthe power cord to the router.4.Wait until the power indicator stops blinking. Wait two minutes before trying to connect tothe Internet from a computer.To reboot your router using Linksys Smart Wi-Fi, do the following:1.Log in to Linksys Smart Wi-Fi. (See “How to connect to Linksys Smart Wi-Fi” on page 13.)2.Under Router Settings, click Troubleshooting.3.Click the Diagnostics tab.4.Under Reboot, click Reboot.5.Click Yes. The router will reboot. While the router is rebooting, all connected devices willlose their Internet connection, and will automatically reconnect when the router is ready again.Linksys Smart Wi-Fi does not open in your web browserThe latest versions of Google Chrome TM, Firefox®, Safari® (for Mac® and iPad®), Microsoft Edge, and Internet Explorer® version 8 and newer work with Linksys Smart Wi-Fi.SpecificationsLinksys WRT3200ACMModel Name Linksys MU-MIMO Gigabit Wi-Fi Router Description Dual-Band AC Router with Gigabit and 2×USB Model Number WRT3200ACMSwitch Port Speed 10/100/1000 Mbps (Gigabit Ethernet)Radio Frequency 2.4 GHz and 5 GHz# of Antennas 4 external adjustable antennasPorts Power, USB 3.0, Combo USB 2.0/eSATA,Internet, Ethernet (1-4), RP-SMA (4)Buttons Reset, Wi-Fi Protected Setup, PowerFront Panel Indicators Power, Internet, 2.4 GHz, 5 GHz, eSATA, USB1,USB2, Ethernet (1-4), Wi-Fi Protected Setup, UPnP SupportedSecurity Features WPA2, RADIUSSecurity Key Bits Up to 128-bit encryptionStorage File System Support FAT, NTFS, and HFS+Browser Support Latest versions of Google Chrome TM, Firefox®,Safari® (for Mac® and iPad®), Microsoft Edge,Internet Explorer® version 8 and newer EnvironmentalDimensions 9.68” x 7.64” x 2.05” (without antennas)(246 x 194 x 52 mm)Unit Weight 31 oz. (883 g)Power 12V, 3.0ACertifications FCC, IC, CE, Wi-Fi a/g/n/ac, Windows 7, Windows8, DLNAOperating Temperature 32 to 104°F (0 to 40°C)Storage Temperature -4 to 140°F (-20 to 60°C)Operating Humidity 10% to 80% relative humidity, non-condensing Storage Humidity 5% to 90% non-condensingNotes:For regulatory, warranty, and safety information, see the CD that came with your router or go to /support/WRT3200ACM.Specifications are subject to change without notice.Maximum performance derived from IEEE Standard 802.11 specifications. Actual performance can vary, including lower wireless network capacity, data throughput rate, range and coverage. Performance depends on many factors, conditions and variables, including distance from the access point, volume of network traffic, building materials and construction, operating system used, mix of wireless products used, interference and other adverse conditions.BELKIN, LINKSYS and many product names and logos are trademarks of the Belkin group of companies. Third-party trademarks mentioned are the property of their respective owners. Licenses and notices for third party software used in this product may be viewed here:/en-us/license. Please contact /en-us/gplcodecenter for questions or GPL source code requests.© 2016 Belkin International, Inc. and/or its affiliates. All rights reserved.LNKPG-00391 Rev. A00。
AN13275如何在新的 iMX8/8X 板上启用 Linux BSP L5.4Rev. 1 — 2023年5月26日应用笔记如何在新的 iMX8/8X 板上启用 Linux BSP L5.4 1 介绍1.1 目标本应用笔记介绍了在新的自定义 i.MX 8/8X 板上启用标准 Linux BSP L5.4 的一般过程,帮助用户快速移植标准Linux BSP 版本代码到自定义 i.MX 8/8X 板上,并提示用户注意那些需要修改的关键部分。
1.2 示例板本应用笔记使用 i.MX 8QXP 汽车参考板作为示例板,因为标准的 Linux BSP 版本不支持该参考板。
更多详细信息,请联系恩智浦代表。
该板的硬件设计基于 i.MX8QXP MEK 板,但有如下变化:•i.MX 8QXP C0 芯片•三星汽车级 LPDDR4 和 eMMC5.1•MIPI-CSI,配备 NVP6324 汽车 AHD 解决方案•LVDS 显示器,配备 TI DS90UB947/948 Serdes(通过FPD Link III),用于汽车应用•MIPI-DSI 显示器,配备 Maxim 96752/96755 Serdes(通过 GMSL2),用于汽车应用•恩智浦 TJA1101 汽车 100 Mbps 以太网 PHY•用于 Carplay/AA 的 USB3.0 host 和用于调试的 USB2.0 OTG图 1. i.MX 8QXP 汽车参考板1.3 Linux BSP 版本本应用笔记以 L5.4.47_2.2.0 Linux BSP 版本为例。
如需查询所有 i.MX Linux BSP 的版本,请参见 Embedded Linux for i.MX Applications Processors。
如何在新的 iMX8/8X 板上启用 Linux BSP L5.4以下章节介绍了移植SCFW、ATF、U-Boot 和 Linux 内核的一般过程。
联想天工R4802路由器硬件安装手册目录第1章产品概述 (1)1.1 产品简介 (1)1.2 技术特性 (1)1.3 产品规格 (2)1.3.1 硬件性能指标 (2)1.4 ROHS说明 (3)第2章天工R4802的介绍 (4)2.1 天工R4802外观说明 (4)2.1.1 机箱 (4)2.1.2 主板说明 (4)2.1.3 电源分布 (4)2.2 R4802通风散热系统 (5)2.3 R4802面板简介 (5)2.3.1 前面板 (5)2.3.2 后面板 (6)第3章安装前准备 (8)3.1 安全性建议 (8)3.1.1 安装系统的安全 (8)3.1.2 搬移的安全 (8)3.1.3 电气安全性 (8)3.1.4 激光安全性 (9)3.2 安装场地的要求 (9)3.2.1 通风要求 (9)3.2.2 温度和湿度要求 (9)3.2.3 洁净度要求 (10)3.2.4 电源要求 (10)3.3 系统接地要求 (10)3.4 安装工具要求 (10)3.5 开箱验货检查要求 (11)第4章产品的安装 (12)4.1 安装流程 (12)4.2 安装确认 (12)4.3 安装机箱 (13)4.3.1 安装机箱于桌面 (13)4.3.2 安装机箱于机柜 (13)4.4 R4802路由器主板安装及维护 (13)4.4.1 安装R4802主板 (13)4.5 连接系统接地 (15)4.6 安装后检查 (16)4.6.1 机柜检查 (16)4.6.2 电缆连接检查 (16)4.6.3 电源检查 (16)4.7 连接监控口 (16)4.7.1 连接Console口 (16)4.7.2 连接AUX口 (18)4.8 搭建配置环境 (18)4.8.1 通过配置口(Console)搭建本地配置环境 (18)第5章硬件故障分析 (20)5.1 故障隔离 (20)5.1.1 电源和冷却系统故障 (20)5.1.2 端口、电缆和连接故障 (20)5.2 指示灯说明 (20)第6章路由器维护 (22)6.1 安装R4802主控板 (22)6.2 更换R4802主控板 (23)6.3 R4802主控板内存升级及BOOT ROM升级 (24)第1章产品概述1.1 产品简介天工R4802高端路由器作为我们公司推出的新款路由器,产品致力企业级汇聚网络;产品设计在保持对业界先进技术密切跟踪的同时,充分考虑了公司多年在路由器领域的研发经验和技术积累,以及对市场的充分了解,提出了简便、适用、新颖的以交换为核心,分布式处理的多处理器体系结构。
DATA SHEETSE5512L: Dual-Band 802.11a/b/g/n Wireless LAN Front-End Preliminary Information▪IEEE802.11b DSSS WLAN▪IEEE802.11g OFDM WLAN▪IEEE802.11a OFDM WLAN▪IEEE802.11n WLAN▪Access Points, PCMCIA, PC cardsOrdering InformationThe SE5512L is a complete 802.11a/b/g/n WLAN RF front-end module providing all the functionality of the power amplifiers, filtering, power detector, T/R switch, diplexers, LNA and associated matching. The SE5512L provides a complete 2.4 GHz and 5 GHz WLAN RF solution from the output of the transceiver to the antenna in an ultra compact form factor. Designed for ease of use, all RF ports are matched to 50 Ω to simplify PCB layout and the interface to the transceiver RFIC. The SE5512L also includes a transmit power detector with 20 dB of dynamic range for each transmit chain. Each transmit chain has a separate digital enable control for transmitter power ramp on/off control. The power ramp rise/fall time is less than 0.7 μsec.The device also provides a notch filter from 3.260-3.267 GHz and 3.28-3.89 GHz prior to the input of each 2.4 GHz and 5 GHz power amplifiers, respectively.The SE5512L packaged in 4mm x 4mm x 0.9mm, Halogen free, Lead free, ROHS compliant, MSL 3 QFN package.DATA SHEETSE5512L: Dual-Band 802.11a/b/g/n Wireless LAN Front-EndPreliminary InformationFunctional Block DiagramfFigure 1: SE5512L Functional Block DiagramDATA SHEETSE5512L: Dual-Band 802.11a/b/g/n Wireless LAN Front-End Preliminary InformationPin Out DiagramFigure 2: SE5512L Pin Out (Top View Through Package)DATA SHEETSE5512L: Dual-Band 802.11a/b/g/n Wireless LAN Front-EndPreliminary InformationThese are stress ratings only. Exposure to stresses beyond these maximum ratings may cause permanent damage to, or affect the reliability of the device. Avoid operating the device outside the recommended operating conditions defined below. This device is ESD sensitive. Handling and assembly of this device should be at ESD protected workstations.Recommended Operating ConditionsDC Electrical CharacteristicsConditions: V CC = 3.3 V, T A = 25 °C, as measured on Skyworks Solutions’ SE5512L-EV1 evaluation board (de-DATA SHEETSE5512L: Dual-Band 802.11a/b/g/n Wireless LAN Front-EndPreliminary InformationConditions: V CC = 3.3 V, T A = 25 °C, as measured on Skyworks Solutions’ SE5512L-EV1 evaluation board (de-Switch/LNA Logic CharacteristicsConditions: V CC = 3.3 V, V EN = 0 V, T A = 25 °C, as measured on Skyworks Solutions’ SE5512L-EV1 evaluationSwitch & LNA Control Logic TableDATA SHEETSE5512L: Dual-Band 802.11a/b/g/n Wireless LAN Front-EndPreliminary Information2.4 GHz Transmit CharacteristicsConditions: V CC = 3.3 V, ENg = 3.3 V, ENa = C0 = C1 = 0 V, T A = 25 °C, as measured on Skyworks Solutions’DATA SHEETSE5512L: Dual-Band 802.11a/b/g/n Wireless LAN Front-EndPreliminary InformationConditions: V CC = C0 = C1 = 3.3 V, ENg = ENa = 0 V, T A = 25 °C, as measured on Skyworks Solutions’ SE5512L-Parameter Condition Min. Typ.Frequency Range - 2400Receive Gain, LNA2400 – 2485 MHz 10 152400 – 2485 MHz, Overany 40MHz band- 0.2De-embedded to device - 2.5@1710-1990MHz With this input , IIP3 canonly degrade by 1dB-10DATA SHEETSE5512L: Dual-Band 802.11a/b/g/n Wireless LAN Front-EndPreliminary Information5 GHz Transmit CharacteristicsConditions: V CC = 3.3 V, ENa = 3.3 V, ENg = C0 = C1 = 0 V, T A = 25 °C, as measured on Skyworks Solutions’DATA SHEETSE5512L: Dual-Band 802.11a/b/g/n Wireless LAN Front-EndPreliminary InformationConditions: V CC = C0 = 3.3 V, ENg = ENa = C1 = 0 V, T A = 25 °C, as measured on Skyworks Solutions’ SE5512L-DATA SHEETSE5512L: Dual-Band 802.11a/b/g/n Wireless LAN Front-End Preliminary InformationConditions: V CC = 3.3 V, ENg = 3.3 V, ENa = C0 = C1 = 0 V, T A = 25 °C, as measured on Skyworks Solutions’Figure 3: SE5512L Power Detector vs. Output Power over Frequency (CW Signal)DATA SHEETSE5512L: Dual-Band 802.11a/b/g/n Wireless LAN Front-End Preliminary InformationConditions: V CC = 3.3 V, ENa = 3.3 V, ENg = C0 = C1 = 0 V, T A = 25 °C, as measured on Skyworks Solutions’Figure 4: Preliminary SE5512L Power Detector vs. Output Power over Frequency (CW Signal)DATA SHEETSE5512L: Dual-Band 802.11a/b/g/n Wireless LAN Front-End Preliminary Information 181716151413191218171615141320111912Figure 5: Package Drawing: TopsideDATA SHEETSE5512L: Dual-Band 802.11a/b/g/n Wireless LAN Front-End Preliminary InformationFigure 6: Recommended Land and Solder PatternsDATA SHEETSE5512L: Dual-Band 802.11a/b/g/n Wireless LAN Front-End Preliminary Information Package Handling InformationBecause of its sensitivity to moisture absorption, instructions on the shipping container label must be followed regarding exposure to moisture after the container seal is broken, otherwise, problems related to moisture absorption may occur when the part is subjected to high temperature during solder assembly. The SE5512L is capable of withstanding a Pb free solder reflow. Care must be taken when attaching this product, whether it is done manually or in a production solder reflow environment. If the part is manually attached, precaution should be taken to insure that the device is not subjected to temperatures above its rated peak temperature for an extended period of time. For details on both attachment techniques, precautions, and handling procedures recommended, please refer to: ▪ “Quad Flat No-Lead Module Solder Reflow & Rework Information”, Document Number QAD-00045 ▪ “Handling, Packing, Shipping and Use of Moisture Sensitive QFN”, Document Number QAD-00044Product BrandingFigure 7: SE5512L Branding InformationCaution! Class 1C ESD sensitive deviceDATA SHEETSE5512L: Dual-Band 802.11a/b/g/n Wireless LAN Front-EndPreliminary InformationFigure 8: Detailed Tape and Reel Information (All diminensions in Millimeters)DATA SHEETSE5512L: Dual-Band 802.11a/b/g/n Wireless LAN Front-EndPreliminary InformationCopyright © 2012 Skyworks Solutions, Inc. All Rights Reserved.Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes.No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and Conditions of Sale.THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury, death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any damages resulting from such improper use or sale.Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters.Skyworks, the Skyworks symbol, and “Breakthrough Simplicity” are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third-party brands and names are for identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at , are incorporated by reference.。
User ManualS-8GE-M-2UG-AI-VLAN8 Port Gigabit Layer 2 PoE SwitchInstallation manual introductionThe Product installation manual mainly describes S-8GE-M-2UG-AI-VLAN PoE switchhardware features, installation methods, and precautions during the installationThis manual includes the following chapters:Chapter 1: Product Introduction. Briefly describes the basic features of the switch and theappearance details.Chapter 2: Product Installation. Guide the switch hardware installation methods andprecautions.Chapter 3: Hardware Connections. Guide the connection between switches and otherdevices and precautions.Chapter 4: Technical Specifications.NOTE:To avoid potential device damage and personal injury, read the related information in this manualbefore installing the device.AgreementThe term "switch" mentioned in this manual, unless otherwise specified, refers to8-port full Gigabit managed PoE switch, hereinafter referred to as S-8GE-M-2UG-AI-VLANSome pictures for the schematic, the product itself and pictures may be differentThis icon indicates the items to be cautioned in the operation. If the operation is wrong, theequipment may be damaged and other adverse consequences.Chapter 1 Product Introduction1.1Product introductionS-8GE-M-2UG-AI-VLAN is managed PoE switch for security transmission and WIFIcoverage, meet the WIFI AP, IP-camera, WIFI bridge, IP phones and other types ofequipment PoE power supply needs. Products using a new generation of high-performance hardware and software platforms, providing flexible, cost-effective full Gigabitaccess and uplink ports, , complete security mechanisms, improved ACL / QoS strategyand rich VLAN capabilities, it is easy to manage and maintain , meet the users'requirements for network equipment easy to manage, high security and low cost. It issuitable for network access, aggregation and core applications in campus, hotel andenterprise campus.PoE (Power over Ethernet) refers to the power over Ethernet technology. It refers to thetransmission of data signals to some IP-based terminals (such as IP phones, wirelessaccess point AP, network cameras, etc.) and also provide DC power supply technology.These devices that accept DC power supply are called powered devices (PD)1.2 Packing listOpen the package carefully check the following list1.3AppearanceFront PanelIncluding indicators, RJ45 port, DIP switch, RST button, SFP port, CONSOLE port, as shown inFigure 1.1 belowIndicators✧Shortcut button◆QOS: Improve video data processing capabilities and improve the monitoring ofCaton and Mosaic phenomena in the network◆Extend: 1-8 port rate down to 10Mbps, but the transmission distance up to 250meters◆VLAN: Isolating ports 1-8 from each other, suppress network storms effectively andimprove network performance◆AI power supply: Detect PD, power failure and restart dead equipment✧RJ45 PortS-8GE-M-2UG-AI-VLAN with 8 10/100/1000Mbps PoE port, all ports support IEEE802.3af andIEEE802.3at standardWhen the switch mode of operation is CCTV mode, 1-8 port can support 250 meters powersupply with 10Mbps speed rate✧SFP PortS-8GE-M-2UG-AI-VLAN provides 2 Gigabit SFP optical ports (SFP1, SFP2), can be inserted into the Gigabit SFP module✧RST Button✧When the switch is powered on, press the button with the needle to release the device and enterthe restarting state. When the SYS lamp restarts, the device restarts. When the switch is powered on, press and hold the button for more than 5s to release the button and enter the reset state.When SYS is re-lit, the device is reset successfully✧✧Console portConsole port used to connect to computer or other terminal to manage or configure the switch.⏹Back PanelIncluding: power socket, power switch, ground terminall✧Power socketA 100-240VAC 50/60 Hz power receptacle for accommodating the supplied power cord✧Ground terminalPlease use the grounding wire to prevent lightning. To avoid product lightning strikes andextend product lifeChapter 2 Installation2.1Installation PrecautionsNote:To avoid improper use of equipment damage and personal injury, pleaseobserve the following precautions⏹Installation safety precautions●The power should be kept off during the installation, while wearing anti-static wrist,and to ensure well touch between anti-static wrist and skin to avoid potential safetyhazard;●The switch just work normally when it is powered by the correct power supply. Makesure that the power supply voltage matches the voltage indicated by the switch●Before powering on the switch, make sure that the power circuit is not overloaded,which may affect the normal operation of the switch and even cause unnecessarydamage●To avoid the risk of electric shock, do not open the case while the switch is working.Do not open the case even when it is not powered●Before cleaning the switch, unplug the switch from the power cord and do not wipe itwith wet cloth. Do not wash it with liquid✧Temperature and humidityTo ensure the long-term stability working of the switch , please maintain a certaintemperature and humidity environment. High or low humidity easily lead to leakage ofinsulation materials, deformation and even the corrosion of metal parts, thetemperature is too high will accelerate the aging process of insulating materials,seriously affecting the service life of equipment. The normal operation of this series ofswitches and storage temperature / humidity are as follows✧AltitudeProducts with this logo are only for safe use in areas below 2000m altitude✧Dust-proofDust on the switch surface will cause electrostatic adsorption, poor contact of the metalcontacts. Although the device itself has done some measures in anti-static, but when thestatic electricity exceeds a certain intensity, it will still cause fatal damage to the electroniccomponents on the internal circuit board. In order to prevent static electricity from affectingthe normal operation of the equipment, please note the following:Regular dust, keep the indoor air clean;Make sure the equipment is well grounded to ensure smooth transfer of static electricity✧Electromagnetic interferenceElectromagnetic interference have an impact on the device capacitance, inductance andother electronic components by capacitance, inductive coupling, impedance coupling andother conductive, in order to reduce the adverse effects caused by electromagneticinterference, please note the following:Power supply system to take the necessary anti-grid interference measures;Switches should be far away from high-frequency high-power, high-current devices, suchas wireless transmitters;If necessary, take electromagnetic shielding measures✧Lightning protectionWhen a lightning strike occurs, a strong current will be generated in an instant cause fataldamage to electronic equipment. To achieve better lightning protection, please note thefollowing:Make sure the rack and the ground to maintain good contact;Make sure the power outlet is in good contact with the earth;Reasonable wiring, to avoid the internal sense ray;Outdoor wiring, it is recommended to use the signal lightning protection device✧ Installation desk requirementRegardless of whether the switch is installed in a rack or on another horizontal workbench,be aware of the following:Make sure the rack or workbench is stable, strong, and can withstand at least 5.5Kgweight;Make sure the rack has a good cooling system, or maintain good indoor ventilation;Make sure the rack is well grounded, the power outlet and switch are within 1.5 meters✧ Prepare tools for installationYou may need to use a screwdriver during installation, electrostatic wrist strap, fiber opticcable and other tools to prepare your own2.2 Product installationInstallation methodS-8GE-M-2UG-AI-VLAN supports desktop mounting and rack mount.:First, Check rack grounding and stability;Second, Install the two L-brackets in the accessory on each side of the switch panel andsecure with the screws provided in the accessoryThird, place the switch in an appropriate place in the rack and be supported by the bracket.Screw the L-shaped bracket to the guide groove fixed on both ends of the rack to ensurethat the switch is stable and horizontally installed on the rackNote:Good grounding rack is anti-static equipment, anti-leakage, lightning protection, anti-jamming important guarantee, so to ensure that the rack ground wire properlyinstalled;Installation equipment within the rack from the bottom up, to avoid overloadinstallation;Avoid placing other heavy objects on switch to avoid accidents;Ensure heat dissipation and air circulation.Chapter3 Hardware connection3.1RJ45 port connectionConnect the RJ45 port of the switch and the corresponding network device via cables, thePOE power supply function of the switch is default enabled on the downlink port of theswitch, which can be used for IEEE802.3af or IEEE802.3at standards powered devices suchas APs, bridges, and network camerasNote:When the switch connected workstations, servers, routers or other ethernet devices thecable length should be within 100 meters;The Auto-MDI / MDIX ethernet interface is enabled by default. Category 5,the standardnetwork cable or crossover cable can be used for Ethernet connection.Do not connect the RJ45 port to the phone line3.2 SFP Port connectionS-8GE-M-2UG-AI-VLAN SFP port only support Gigabit fiber module. Recommended use ofstandard SFP module productsThe process of installing a fiber module on a switch is as follows:First, grasp the optic fiber module from the side, insert it smoothly along the SFP port slotuntil the optic fiber module and switch are in close contact;Second, confirm the Rx and Tx ports of the fiber module when connecting, insert one end ofthe fiber into the Rx and Tx ports correspondingly, ensure that the Tx and Rx ends of theinterface are connected correctly and the other end of the fiber is connected to anotherdevice;Third, please check the corresponding indicator light status after power on. If the lightblinking that the link is properly connected, if the light is off , the link is failure, please checkthe line to confirm that the corresponding equipment is enabled.Note:Does not allow excessive bending fiber, the radius of curvature should notbe less than 10cm;Ensure the cleanliness of the fiber surface;Please do not look directly into the optical fiber connector with your eyesas this may cause eye injury3.3 Check before power onCheck whether the outlet power supply meets the switch specifications;Check the power, switches, racks and other equipment have been properly grounded;Check whether the switch and other network devices are connected properly3.4 Device initializationThe switch automatically initializes when the power switch is turned on.Indicator will appear the following situation:After the power is turned on, the power indicator remains on, the other indicator is off atthis time;After about 1 second, all lights except for the power light turn on for about 35 seconds andthen turn off; when the SYS light goes flashing, the system runs normallyPort LEDs indicates the connection status of each port, indicating that the switch hasstarted to work normally3.5 Web LoginStep1、In the normal operation of the device, connect the computer to the switch's RJ45 port bynetwork cablesStep 2、 Manually changed the computer IP address to 192.168.254.X (X is 2 ~ 254), subnet mask is 255.255.255.0Step3、Open computer's browser, type 192.168.254.1 in the address box, hit the Enter key Step4、Enter the default username and p assword “admin” and then click LoginStep5、Entered the switch web management interface successfully when you see picture as below, you can begin to configure the switchChapter 4 Hardware Specifications4.1Hardware Specifications4.2 Software Specifications4.2 Features1-8 port support 250Meters long-distance power supply (recommended cat5e or 6network cable)Support a key VLAN, the port 1-8 isolated from each other, which can effectivelyinhibit network storms, improve network performanceSupports IEEE 802.3af / at standard, automatically detects and identifies devices thatcomply with the IEEE 802.3af / at standard and supply power to itSupport Auto MDI/MDIX;Adopt store-and-forward exchange methodintelligent power supply, the lowest power consumption, ensure PD power needsWith power circuit protection, protect the safety of PDNo configuration characteristics of the power supply is automatically supplied to the adaptive equipment;Fanless design, energy saving and environmental protection; no noise, reduce the impact on the environmentSmall, exquisite designSupport port without link power saving functionAll ports have wire-speed forwarding capabilityPlug and play, easy to use。
EDS-608系列8埠小巧模組化網管型乙太網路交換器特色與優點•模組化設計,擁有4埠銅質/光纖組合•支援熱插拔媒體模組,允許不斷電下連續運作•Turbo Ring 和Turbo Chain (對於250台交換器,復原時間小於20毫秒),以及STP/RSTP/MSTP ,以實現網路冗餘•支援TACACS+、SNMPv3、IEEE 802.1X 、HTTPS 和SSH ,強化網路安全•透過網頁瀏覽器、CLI 、Telnet /序列主控台、Windows 工具程式和ABC-01輕鬆管理網路•支援MXstudio ,輕鬆進行視覺化工業網路管理認證簡介小巧的EDS-608系列的多功能模組化設計能夠讓使用者合併光纖和銅質模組,以便建立適合任何自動化網路的交換器解決方案。
EDS-608的模組化設計可讓您安裝8個快速乙太網路連接埠,而進階的Turbo Ring 和Turbo Chain (復原時間小於20毫秒)技術、RSTP/STP 以及MSTP 則可協助增加您的工業乙太網路的可靠性與可用性。
同時也提供寬溫(-40至75°C )的型號選擇。
EDS-608系列支援數個可靠以及智慧的功能,包括EtherNet/IP 、Modbus TCP 、LLDP 、DHCP Option 82、SNMP Inform 、QoS 、IGMP snooping 、VLAN 、TACACS+、IEEE 802.1X 、HTTPS 、SSH 、SNMPv3以及更多功能,使得乙太網路交換器適合任何惡劣的工業環境。
附加特色與優點•命令列介面(CLI )快速設定主要網管功能•SNMP Inform 可用於確保可靠的事件管理•LLDP 可用於進行自動拓樸搜索•DHCP Option 82適用於以不同原則指派IP 位址•EtherNet/IP 和Modbus TCP 通訊協定可用於進行設備管理和監控•相容於PROFINET 通訊協定以進行透通式數據傳輸•發生例外狀況時透過電子郵件和繼電器輸出自動發出警告•IGMP 和GMRP ,用於篩選多播流量•可基於連接埠實現VLAN 、IEEE 802.1Q VLAN 以及GVRP ,以簡化網路規劃•QoS (IEEE 802.1p/1Q 和TOS/DiffServ )可增加確定性•連接埠聚合可提供最佳頻寬使用率•SNMPv1/v2c/v3,適用不同層級的網路管理•RMON 提供主動且有效率的網路監控•頻寬管理可防止無法預測的網路狀態•鎖定連接埠功能可根據MAC 位址封鎖未經授權的存取•埠鏡像可用於線上除錯規格Input/Output InterfaceDigital Inputs+13to +30V for state 1-30to +3V for state 0Max.input current:8mAAlarm Contact ChannelsRelay output with current carrying capacity of 1A @24VDCEthernet InterfaceModule2slots for any combination of4-port interface modules,10/100BaseT(X)or100BaseFX Standards IEEE802.1D-2004for Spanning Tree ProtocolIEEE802.1p for Class of ServiceIEEE802.1Q for VLAN TaggingIEEE802.1s for Multiple Spanning Tree ProtocolIEEE802.1w for Rapid Spanning Tree ProtocolIEEE802.1X for authenticationIEEE802.3for10BaseTIEEE802.3ad for Port Trunk with LACPIEEE802.3u for100BaseT(X)and100BaseFXIEEE802.3x for flow controlEthernet Software FeaturesFilter GMRP,GVRP,IGMP v1/v2,Port-based VLANIndustrial Protocols EtherNet/IP,Modbus TCPManagement Back Pressure Flow Control,BOOTP,DHCP Option66/67/82,DHCP Server/Client,Flowcontrol,IPv4/IPv6,LLDP,Port Mirror,RARP,RMON,SMTP,SNMP Inform,SNMPv1/v2c/v3,Syslog,Telnet,TFTPMIB Bridge MIB,Ethernet-like MIB,MIB-II,P-BRIDGE MIB,Q-BRIDGE MIB,RMON MIBGroups1,2,3,9,RSTP MIBRedundancy Protocols Link Aggregation,MSTP,RSTP,STP,Turbo Chain,Turbo Ring v1/v2Security Broadcast storm protection,HTTPS/SSL,Port Lock,RADIUS,SSH,TACACS+Time Management NTP Server/Client,SNTPSwitch PropertiesIGMP Groups256MAC Table Size8KMax.No.of VLANs64Packet Buffer Size1MbitsPriority Queues4VLAN ID Range VID1to4094LED InterfaceLED Indicators PWR1,PWR2,FAULT,MSTR/HEAD,CPLR/TAILSerial InterfaceConsole Port RS-232(TxD,RxD,GND),8-pin RJ45(115200,n,8,1)DIP Switch ConfigurationEthernet Interface Turbo Ring,Master,Coupler,ReservePower ParametersConnection1removable6-contact terminal block(s)Input Voltage12/24/48VDC,Redundant dual inputsOverload Current Protection SupportedReverse Polarity Protection SupportedPhysical CharacteristicsIP Rating IP30Dimensions125x151x157.4mm(4.92x5.95x6.20in) Weight1,950g(4.30lb)Installation DIN-rail mounting,Wall mounting(with optional kit) Environmental LimitsOperating Temperature EDS-608:0to60°C(32to140°F)EDS-608-T:-40to75°C(-40to167°F)Storage Temperature(package included)-40to85°C(-40to185°F)Ambient Relative Humidity5to95%(non-condensing)Standards and CertificationsFreefall IEC60068-2-32EMC EN55032/35,EN61000-6-2/-6-4EMI CISPR32,FCC Part15B Class AEMS IEC61000-4-2ESD:Contact:6kV;Air:8kVIEC61000-4-3RS:80MHz to1GHz:10V/mIEC61000-4-4EFT:Power:4kV;Signal:4kVIEC61000-4-5Surge:Power:2kV;Signal:2kVIEC61000-4-6CS:10VIEC61000-4-8PFMFHazardous Locations ATEX,Class I Division2Maritime ABS,DNV-GL,LR,NKRailway EN50121-4Safety EN62368-1,UL508Shock IEC60068-2-27Traffic Control NEMA TS2Vibration IEC60068-2-6MTBFTime596,219hrsStandards Telcordia(Bellcore),GBWarrantyWarranty Period5yearsDetails See /tw/warrantyPackage ContentsDevice1x EDS-608Series switchCable1x RJ45-to-DB9console cableDocumentation1x product certificates of quality inspection,Simplified Chinese1x product notice,Simplified Chinese1x quick installation guide1x warranty cardNote Modules from the CM-600Module Series need to be purchased separately for use withthis product.尺寸訂購資訊Model Name Layer Total No.of PortsModule10/100BaseT(X)and/or100BaseFXOperating Temp.EDS-608282slots for up to810/100BaseT(X)and/or100-BaseFX ports0to60°CEDS-608-T282slots for up to810/100BaseT(X)and/or100-BaseFX ports-40to75°C配件(選購)CM-600Module SeriesCM-600-4TX Fast Ethernet interface module with410/100BaseT(X)ports,RJ45connectors,-40to75°C operatingtemperatureCM-600-4MSC Fast Ethernet interface module with4100BaseFX multi-mode ports,SC connectors,-40to75°Coperating temperatureCM-600-4MST Fast Ethernet interface module with4100BaseFX multi-mode ports,ST connectors,-40to75°Coperating temperatureCM-600-4SSC Fast Ethernet interface module with4100BaseFX single-mode ports,SC connectors,-40to75°Coperating temperatureCM-600-3MSC/1TX Fast Ethernet interface module with110/100BaseT(X)port,RJ45connector,and3100BaseFX multi-mode ports,SC connectors,-40to75°C operating temperatureCM-600-3SSC/1TX Fast Ethernet interface module with110/100BaseT(X)port,RJ45connector,and3100BaseFX single-mode ports,SC connectors,-40to75°C operating temperatureCM-600-2MSC/2TX Fast Ethernet interface module with210/100BaseT(X)ports,RJ45connectors,and2100BaseFX multi-mode ports,SC connectors,-40to75°C operating temperatureCM-600-2SSC/2TX Fast Ethernet interface module with210/100BaseT(X)ports,RJ45connectors,and2100BaseFX single-mode ports,SC connectors,-40to75°C operating temperatureStorage KitsABC-01Configuration backup and restoration tool for managed Ethernet switches and AWK Series wireless APs/bridges/clients,0to60°C operating temperaturePower SuppliesDR-120-24120W/2.5A DIN-rail24VDC power supply with universal88to132VAC or176to264VAC input byswitch,or248to370VDC input,-10to60°C operating temperatureDR-452445W/2A DIN-rail24VDC power supply with universal85to264VAC or120to370VDC input,-10to50°Coperating temperatureDR-75-2475W/3.2A DIN-rail24VDC power supply with universal85to264VAC or120to370VDC input,-10to60°C operating temperatureMDR-40-24DIN-rail24VDC power supply with40W/1.7A,85to264VAC,or120to370VDC input,-20to70°Coperating temperatureMDR-60-24DIN-rail24VDC power supply with60W/2.5A,85to264VAC,or120to370VDC input,-20to70°Coperating temperatureSoftwareMXview-50Industrial network management software with a license for50nodes(by IP address)MXview-100Industrial network management software with a license for100nodes(by IP address)MXview-250Industrial network management software with a license for250nodes(by IP address)MXview-500Industrial network management software with a license for500nodes(by IP address)MXview-1000Industrial network management software with a license for1000nodes(by IP address)MXview-2000Industrial network management software with a license for2000nodes(by IP address)MXview Upgrade-50License expansion of MXview industrial network management software by50nodes(by IP address)Wall-Mounting KitsWK-75Wall-mounting kit,2plates,8screws,75x90x2.5mm©Moxa Inc.版權所有.2021年1月11日更新。
ZM602系列Wi-Fi模块用户手册Wi-Fi模块UM01010101 1.2 Date:2022/9/16类别内容关键词ZM602模块,Wi-Fi+BLE,用户手册摘要©2022 Guangzhou ZHIYUAN Electronics Co., Ltd.修订历史文档版本日期原因V1.00 2022.04.25 首次发布V1.01 2022.08.18 新增产品实物图;新增特色功能说明;更新产品选型表;优化快速使用说明;优化BLE数据透传说明;新增数据通道说明;新增串口命令:读取设备MAC地址、读取STA连接状态、读取连接到本设备的STA列表目录1. 产品简介 (1)1.1 概述 (1)1.2 产品特性 (1)1.3 典型应用 (2)1.4 产品选型表 (2)2. 快速使用说明 (3)2.1 与设备建立连接 (3)2.2 设置Wi-Fi工作模式 (4)2.3 使用设备连接其他热点 (5)3. 产品功能 (7)3.1 Wi-Fi数据透传 (7)3.1.1 场景一:模块数据互传 (7)3.1.2 场景二:模块与笔记本电脑进行数据互传 (12)3.2 BLE数据透传 (13)4. 工作模式 (16)4.1 网络工作模式 (16)4.1.1 数据通道 (16)4.1.2 TCP Server模式 (17)4.1.3 TCP Client模式 (18)4.1.4 UDP Client模式 (18)4.1.5 UDP Server模式 (18)4.1.6 MQTT Client模式 (19)4.2 Wi-Fi工作模式 (19)4.2.1 AP模式 (19)4.2.2 STA模式 (19)4.2.3 AP+STA模式 (19)5. 配置设备 (20)5.1 网页配置 (20)5.1.1 登录设备网页 (20)5.1.2 系统 (20)5.1.3 专家 (20)5.1.4 串口 (20)5.1.5 网络 (21)5.1.6 无线 (21)5.1.7 热点 (22)5.1.8 用户登录 (22)5.1.9 系统管理 (22)5.1.10 软件更新 (22)5.2 蓝牙快速配网 (23)5.3 串口协议指令 (25)5.3.1 基本原则 (25)5.3.2 封包结构 (26)5.3.3 命令列表 (28)5.3.4 事件列表 (28)5.3.5 命令解析 (29)6. 免责声明 (42)ZM602系列Wi-Fi模块用户手册Wi-Fi模块1.产品简介1.1 概述ZM602系列Wi-Fi模块是广州致远电子股份有限公司基于博流BL602系列芯片开发的高性能Wi-Fi+BLE模块产品。
交流电能表应用中CS5480的一般配置
SSEL脚接高电平,选择UART模式。
MCU将UART配置为600波特率。
RESET保持低电平1ms硬件复位芯片。
SerialCtrl寄存器为0x0204CF,设置CS5480为9600波特率。
MCU将UART配置为9600波特率。
如果EEPROM中有有效的相位补偿数据,则读出该校准数据并写入到PC寄存器。
如果EEPROM中有有效的电压/电流增益和功率偏移量寄存器校准数据,则读出该校准数据并写入到电压电流/增益和功率偏移量寄存器。
先设置PulseWidth寄存器为0x0613F0。
频率范围31.25~0.003725Hz,脉冲宽度80ms。
然后设置PulseRate寄存器为0x494D00。
//(220*10*1200/3600000/0.0409781932830810546875)/2000*2^6*2^23 //=17.895697066666666666666666666667/2000*2^6*2^23
//=0x494D00
在交流应用中,为了简化校准步骤打开高通滤波器。
设置Config2寄存器的I2FLT[1:0]、V2FLT[1:0]、I1FLT[1:0]和V1FLT[1:0]位为‘01’。
Config2寄存器的MCFG[1:0]位设为‘00’,选择1V,1I+Neutral模式。
Config2寄存器的IHOLD位为‘0’,IVSP为‘0’,根据P1avg和P2avg大小自动选择电能计量通道;IHOLD位为‘1’,根据ICHAN位选择电能计量通道。
(如DSP_LOCK=0x16则只能使用手动选择电能计量通道)
Config2寄存器的AFC位为‘1’,开启频率测量。
设置SampleCount寄存器为0x000FA0。
设置Ichlevel寄存器(防窃电),使通道选择电平为1.25,即当P1AVG和P2AVG>Emin,且P1AVG和P2AVG中的一个大于另一个的1.25倍时,选择大的一个作为当前电能通道,否则保持当前选择。
Ichlevel=0xA00000。
(如DSP_LOCK=0x16则Ichlevel不需要设置)
设置Emin寄存器(防窃电),使通道选择最小幅度为额定功率的0.04%。
Emin=0.04%*0.537109375*0.0762939453125(220V对应0.537109375倍最大电压有效值(0xFFFFFF),10A对应0.0762939453125倍最大电流有效值(0xFFFFFF))=0.000040978=0x000158。
(如DSP_LOCK=0x16则Ichlevel不需要设置)设置Loadmin寄存器(用于防潜动)=0.0000164=0x000089。
参考AN337
设置TGAIN寄存器为0x06B716,TOFF寄存器为0xD53998。
设置Config0寄存器的I2PGA[1:0]和I1PGA[1:0]位, 选择合适的电流PGA 增益(在这里设置I2PGA[1:0]=‘00’,I1PGA[1:0]=‘10’)。
(bit22也需要设为'1')
设置PulseCtrl为0x000002,选择Psum作为EPG1的输入。
设置Config1寄存器为0x10EEE0,使能EPG1,选择EPG1驱动DO1脉冲输出。
设置RegLock寄存器为0x001616,开启寄存器写保护和DSP Lockout。
正常复位后DRDY位为‘1’。
写入0x800000到状态寄存器(Status0)清除DRDY位。
发送连续转换命令0x15。
CS5480软件校准
说明:本文档中Vgain或Igain的小数形式含义为1.0=0x400000,其它值按比例变化。
Vrma或Irms的小数形式含义为1.0=0xFFFFFF,其它值按比例变化。
这里以Un=220V,Ib=10A,Imax=60A的单相电能表为例说明CS5480的软件校准。
电压通道用电阻网路分压,当输入220V时VIN±输入信号约120mV。
电流通道1用250uohm锰铜,输入10A时,锰铜两端电压约2.5mV;电流通道2用变比为2000:1的电流互感器,取样电阻5.1ohm,输入10A时,取样电阻两端电压约25.5mV。
假设已经打开了电压和电流通道高通滤波器。
1.校准电压增益和电流增益、补偿相位(100%Un,100%Ib,PF=0.5L)
校准电压增益前,先将V1gain(V2gain)设为1.0,从CS5480的电压有效值寄存器V1rms(V2 rms)读出当前电压有效值(16进制)。
由于U=220V时,VIN ±输入信号约120mV,为最大输入值250mV的50%,因此将0x897FFF(Vrms最大值的53.7109375%)除以当前电压有效值,将商写入电压增益寄存器。
校准电流增益前,先将I1gain(I2 gain)设为1.0,从CS5480的电流有效
值寄存器I1rms (I2 rms )读出当前电流有效值(16进制)。
将0x 138800(Irms 最大值的7.62939453125%)除以当前电流有效值,将商写入电流增益寄存器。
从CS5480读出功率因数,根据功率因数计算CPCCx 和FPCCx 的值,并将其写入到PC 寄存器中。
默认情况下,50Hz 时相位补偿的最小步进为0.008789°,相位调整范围为-8.99°~8.99°。
假设θ=60°-accos(PF)
当4.5°<θ<=9°,CPCCx=‘01’,FPCC=(θ-4.5)/0.008789
当0°<θ<=4.5°,CPCCx=‘00’,FPCC=θ/0.008789
当-4.5°<θ<=0°,CPCCx=‘10’,FPCC=(4.5+θ)/0.008789
当-9°<θ<=-4.5°,CPCCx=‘11’,FPCC=(9+θ)/0.008789
2. 校准功率偏移量(100%Un,5%Ib,PF=1.0)
从CS5480读出有功功率P ,从标准表读出有功功率P’。
(P 和P ’值需要有足够的小数位以保证计算精度)。
根据P’-P 的值确定P1offset (P2offset )寄存器的值,将其写入P1offset (P2offset )寄存器中。
3.校准电流交流偏移量(可选)(100%Un,0%Ib,PF=1.0)
使用CS5480内部的电流交流偏移量校准命令。
4.如何确定PulseRate 寄存器的大小
在交流增益校准之后,假设Vrms 在100%Un 时等于53.7109375%最大电压有效值,Irms 在100%Ib 时等于7.62939453125%最大电流有效值。
PulsePate into 0x494D0022048
/)/(2 003725.0~25.310110
]0:3[_06676666666666666666666617.89569706875
32830810540.040978191200
3600100010220)/()/(23
6
=⨯⨯==⨯÷÷⨯=⨯=
K MCLK PulseRate PulseRate Write Hz
Hz RNG FREQ xFFFFFF FS Hz
FS I FS V FREQ RMS RMS P 为选择电能脉冲频率范围为所以设置。
代表最大有效值,等于上式中最大脉冲频率
将PulseRate 写入到PulseRate 寄存器中。
5.将校准数据保存到EEPROM 中。