表2桩抗拔承载力计算
- 格式:xls
- 大小:308.50 KB
- 文档页数:4
抗拔桩计算公式Nk≤Tuk/2+GpNk = 330kNTuk = Σλiqsikuili = 4×0.4×(0.68×35×2.4+0.68×40×2.5+0.72×50×3.5+0.72×72×5.6) = 866.28kNGp = 0.4×0.4×14×(25-10) = 33.6kNTuk/2+Gp = 1129.32/2+39.58 = 466.74kN>330kN满足·群桩竖向抗拔承载力《建筑桩基技术规范》 5.4.5-1Nk≤Tgk/2+GgpNk = 330kNn = 3Tgk = ulΣλiqsikli /n= 5.2×(0.68×35×2.4+0.68×40×2.5+0.72×50×3.5+0.72×72×5.6) = 938.47kNGgp = 1.68×14×(20-10)/3 = 78.4kNTgk/2+Ggp = 938.47/2+78.4 = 547.14kN>330kN满足·桩身受拉承载力《建筑桩基技术规范》5.8.7拉力全部由钢筋提供,已知桩所受轴向拉力N = 330kN。
钢筋等级为HRB400。
预应力筋抗拉强度设计值为1000MPa,用4根直径为9mm的预应力筋N≤fyAs+fpyApsAps = 4×64 = 256mm²As = (N-fpyAps)/fy = (330×1000-1000×256)/360 = 206mm²根据《先张法部分预应力方桩》第5页非预应力筋主筋直径不应小于14mm,A组桩最小配筋率不小于0.6%根据最小配筋率则所需要钢筋截面面积至少为As+Aps = A×0.6% = 960mm²所需非预应力筋的钢筋截面面积为As = 960-256 = 754mm²配4根16的钢筋,实配面积As = 804mm²此时桩身受拉承载力fyAs+fpyAps = 360×804+1000×256 = 545.44kN。
桩径取0.6桩径取0.5桩径取0.8
抗拔系数0.5抗拔系数0.5抗拔系数
抗拔极限承载力标准值641.85抗拔极限承载力标准值534.87抗拔极限承载力标准值抗拔承载力特征值380.30抗拔承载力特征值308.67抗拔承载力特征值
竖向承载力特征值783.21724竖向承载力特征值633.046093竖向承载力特征值
抗拔承载力特征值取380
竖向承载力特征值780
桩间距1.8
四桩群桩抗拔极限承载力标准值773.38334三桩群桩抗拔极限承载力标准值
特征值545.80727特征值
注:黄色区域为数据输入区,
绿色区为计算过程中两个重要参数区
粉色区为最终的单桩竖向极限承载力标准值
必须保留此空行
取此值
0.5
抗拔极限承载力标准值855.79
抗拔承载力特征值533.45
竖向承载力特征值1107.121
三桩群桩抗拔极限承载力标准值826.8718
536.6359。
桩抗拔承载力计算
桩抗拔承载力计算是通过计算桩的周围土体的抵抗力和桩身的承载能力来确定桩的抗拔承载力。
具体的计算方法如下:
1. 确定桩的几何参数,包括桩的直径、长度等。
2. 根据桩的几何参数和地下土体的物理力学性质,计算出桩周围土体的抵抗力。
3. 根据桩的截面形状和材料特性,计算出桩身的承载能力。
4. 根据桩周围土体的抵抗力和桩身的承载能力,计算出桩的抗拔承载力。
在计算桩周围土体的抵抗力时,需要考虑土壤的特性,包括土壤的密度、水分含量、抗剪强度等。
通常采用的计算方法有皮尔逊公式、比安奇公式、哈里森公式等。
在计算桩身的承载能力时,需要考虑桩的材料特性,包括桩的受压强度、抗弯强度等。
通常采用的计算方法有极限承载力法、单位桩侧阻力法、挤压桩法等。
需要注意的是,桩的抗拔承载力计算涉及的参数较多,计算过程较为繁琐。
因此,在实际工程中,通常需要进行现场试验验证计算结果的准确性。
抗拔管桩承载力计算
单桩抗拔承载力特征值:实取:200kN
抗拔桩桩芯砼高度计算(Φ500mm,内径Φ250mm):
桩内直径Φ300mm
桩芯砼灌注长度4m
抗拔承载力设计值400 kN
桩芯砼強度等級C30
桩芯砼与桩内壁粘结强度设计值ƒn0.3N/mm^2
桩芯砼抗拉计算值=0.106157113N/mm^2<ƒn=0.3N/mm^2
满足砼抗拉要求!
抗拔桩钢筋计算:
实配钢筋直径:20mm
钢筋抗拉强度标准值ƒyk360N/mm^2
实配钢筋根数:6实配配筋面As1884mm^2
桩芯砼抗拉计算值=:212.31N/mm^2<ƒyk360N/mm^2
满足钢筋抗拉要求!
接桩节点焊缝计算
对接焊缝受拉强度设计值ƒtw120N/mm^2
对接焊缝厚度10mm
桩直径Φ300mm
抗拔承载力标准值400 kN
对接焊缝抗拉计算值42.46284501N/mm^2<ƒtw120N/mm^2
满足焊缝抗拉要求!。
砼等级边长或直径(mm)周长Up(m)桩端标高(绝对标高)桩顶标高(绝对标高)桩长(m)有效桩长(m)单桩自重GpC803501.400-18.42.62120.933.44层底绝对标高承台下桩土层厚度(m)承台下桩埋深(m)层底绝对标高承台下桩土层厚度(m)承台下桩埋深(m)层底绝对标高承台下桩土层厚度(m)承台下桩埋深(m)地表(孔顶) 3.433.45 3.41填土①0 2.230.270.27 2.150.350.35 1.810.690.69粉质粘土②1150.70.53 1.7 1.970.45 1.7 2.050.21 1.6 2.29粉砂②3400.6-2.87 3.4 5.37-2.553 5.05-3.19 3.4 5.69淤泥质粉质粘土③200.7-6.57 3.79.07-6.5549.05-6.59 3.49.09淤泥质粘土④1250.8-11.074.513.57-14.55817.05-14.197.616.69粉质粘土⑤1-a 450.8-17.07619.57-16.55219.05-17.69 3.520.19粉砂⑤27020000.65-23.07 1.3320.9-23.85 1.8520.9-24.690.7120.9粘土⑤3-1558000.8-30.7700-25.9500-26.7900粉质粘土⑦17020000.7-32.0700-31.9500-32.9900粘质粉土夹粉质粘土⑦2-110060000.65-41.8700-41.8500-36.59000000000孔号端阻力fp桩端极限阻力Rpk=fpAp Σfsili 桩侧总极限摩阻力Rsk=UpΣfsili Rk=Rsk+Rpk 端阻比ρp =Rpk/Rk桩端阻力分项系数γp总侧摩阻力分项系数γs 单桩竖向承载力设计值Rd=Rsk/γs+Rpk/γp Σλifsili单桩竖向抗拔承载力设计值R'd=UpΣλifsili/γs+Gp J22000245.00711.10995.541240.540.197 1.118 1.788775.93517.77486.49G2*******.00645.00903.001148.000.213 1.136 1.798717.86462.03437.71TYC32000245.00625.20875.281120.280.2191.1421.801700.39456.31432.71J22000350.00888.881244.431594.430.220 1.143 1.802996.79G22000350.00806.251128.751478.750.237 1.164 1.812923.61TYC32000350.00781.501094.101444.100.2421.1711.815901.60桩基单桩承载力计算表1J2G2TYC3桩型选择2截面积Ap (m^2)承台底标高(绝对标高)0.123注: 1.请用户输入白色底框内数值,无该项则不需输入数值。
桩承载力计算书持力土层6层边长400抗拔(工程桩) 22m(-5.70)C9Rtk=4x0.4x(25x12.72x0.7+45x4.2x0.7+80x1.7x0.75+70x3.38x0.7)=4x0.4x622.5=996G=0.4x0.4x(22-0.05)x(25-10)=52.7Rtd=(996+52.7)/2=524kN取Nk=520kN桩接头焊缝长度连接BQ=520x2/1.6=650kNQ=Lw’*he*fwt/1.2 fwt=170MPa he=0.75s=0.75x6=4.5mm Lw’=16Lw/2=8Lw Lw=650x1000x1.2/4.5/170/8=127mm图集Lw=160mm桩顶锚固筋As=Q/fy=520x2/1.6x1000/360=1805mm2取8d20 As=2513mm2《建筑桩基技术规范》3.5.3条工程桩裂缝控制值为0.3mm《建筑桩基技术规范》4.1.5条混凝土保护层厚度30mm地下室抗浮(水位标高室外地坪下0.5m):一般部位柱网尺寸8.1x8.1水位高度 6.0+0.1+0.6-0.5=6.2m板自重25x0.6+20x0.1+20x0.02+25x0.25+16x1.0=39.6kN/m2柱、梁自重25x0.5x0.5x3.3+25x0.35x(0.8-0.25)x(8.1+8.1) =98.5kNG=39.6x8.1x8.1+98.5+520x4=4776kN F=6.2x10x8.1x8.1=4067kNG/F=1.17>1.05 安全抗拔(试桩) 26m(-1.900)C9Rtk=4x0.4x(32x0.5x0.7+25x15.1x0.7+45x4.2x0.7+80x1.7x0.75+70x3.58x0.7)=4x0.4x685.1=1096G=0.4x0.4x26x(25-10)=62.4 Rtd=(1096+62.4)/2=579kN试桩加荷值为1200裂缝控制验算计算书(工程桩)1.1 基本资料1.1.1 工程名称:工程一1.1.2 矩形截面轴心受拉构件,构件受力特征系数αcr =2.7,截面尺寸 b×h = 400×400mm 1.1.3 纵筋根数、直径:第 1 种:8Φ20,受拉区纵向钢筋的等效直径 deq =∑(ni·di2) / ∑(ni·υ·di) = 20mm,带肋钢筋的相对粘结特性系数υ= 11.1.4 受拉纵筋面积 As = 2513mm2,钢筋弹性模量 Es = 200000N/mm21.1.5 最外层纵向受拉钢筋外边缘至受拉区底边的距离 cs = 30mm,纵向受拉钢筋合力点至截面近边的距离 as = 40mm,h0 = 360mm1.1.6 混凝土轴心抗拉强度标准值 ftk =2.01N/mm2 C301.1.7 按荷载准永久组合计算的轴向力值 Nq = 550kN1.1.8 设计时执行的规范:《混凝土结构设计规范》(GB 50010-2010),以下简称混凝土规范1.2 最大裂缝宽度验算1.2.1 按有效受拉混凝土截面面积计算的纵向受拉钢筋配筋率ρte,按下式计算:ρte = As / Ate (混凝土规范式 7.1.2-4)对矩形截面的轴心受拉构件:Ate = b·h = 400*400 = 160000mm2ρte = As / Ate = 2513/160000 = 0.015711.2.2 在荷载准永久组合下受拉区纵向钢筋的应力σsq,按下列公式计算:轴心受拉:σsq = Nq / As (混凝土规范式 7.1.4-1)σsq =550000/2513 = 219N/mm21.2.3 裂缝间纵向受拉钢筋应变不均匀系数ψ,按混凝土规范式 7.1.2-2 计算:ψ= 1.1 - 0.65ftk / (ρte·σsq) =1.1-0.65*2.01/(0.01571*219) = 0.7211.2.4 最大裂缝宽度ωmax,按混凝土规范式 7.1.2-1 计算:ωmax =αcr·ψ·σsq·(1.9cs + 0.08deq / ρte ) / 1.5Es= 2.7*0.721*219*(1.9*30+0.08*20/0.0157)/ 1.5 *200000= 0.225mm ≤ωlim = 0.3mm,满足要求。
管桩抗抜计算前两节桩
在进行管桩抗抜计算时,需要先计算前两节桩的抗抜承载力。
首先,需要确定前两节桩的长度、直径和材质等参数。
假设第一节桩的长度为L1,直径为d1,第二节桩的长度为L2,直径为d2。
假设桩材料的抗拉强度为σ,桩与土的摩擦角为φ。
接下来,我们可以按照以下步骤进行前两节桩的抗抜计算:
1. 计算桩与土的摩擦力:
桩与土的摩擦力可以由下式计算得到:
Ff = π * ((d1/2)^2 - (d2/2)^2) * σ * tan(φ)
其中,Ff为桩与土的摩擦力。
2. 计算桩的抗拉力:
桩的抗拉力可以由下式计算得到:
Ft = π * (d1/2)^2 * σ
其中,Ft为桩的抗拉力。
3. 计算前两节桩的抗抜弯矩:
前两节桩的抗抜弯矩可以由下式计算得到:
M = Ff * L1 + Ft * L2
其中,M为前两节桩的抗抜弯矩。
4. 判断抗抜能力:
比较计算得到的抗抜弯矩M和外部施加的弯矩Mr,如果M 大于或等于Mr,则前两节桩具有足够的抗抜能力;如果M小
于Mr,则前两节桩可能会发生抗抜失效,需要进行其他措施加固。
需要注意的是,以上计算仅考虑了前两节桩的抗抜能力,实际工程中可能需要考虑更多桩节的抗抜情况,并进行综合分析和设计。
同时,为了保证抗抜计算的准确性,在实际工程中还需要考虑桩与土的相互作用、土的性质等因素,并进行更详细的计算和分析。