测水笔使用说明书
- 格式:pdf
- 大小:131.83 KB
- 文档页数:3
简述
多功能⽔质检测笔主要⽤于检测⽔的TDS (溶解性总固体,单位为ppm)值和电导率(溶液的导电能⼒,单位为μS/cm)值,判断⽔的纯净程度,同时兼有检测⽔温和环境温度的功能。
本产品可⼴泛应⽤于⽔处理⾏业、家庭、野外等场所的⽔质检测。
1.开机:
在关机状态下,单击按键
即可开机
2.测量状态:单击按键,可切换不同的测量参数
3.锁定功能:双击按键,锁定所有
测量值,再次双击按键解锁
4.关机:⻓按按键约2秒关机(或⽆操作2分钟后⾃动关机)
多功能⽔质检测笔说明书
性能指标
按键功能V1.00
使⽤⽅法
1.⾸次使⽤多功能⽔质检测笔前,需取出电池仓内的电池绝缘⽚(如图⼀所⽰)
2.取下笔帽,按下按键,开机显⽰ppm界⾯
3.将多功能⽔质检测笔放⼊待检测的⽔中,轻轻搅动出笔中⽓泡(注:溶液建议不⾼出浸没线)(如图⼆、图三所⽰)
4.检测笔测量数值受温度影响较⼤,因此需要温度补偿来校正读数,待读数稳定(⼤约2秒),观看显⽰屏的数值,也可通过双击按键锁定测量数值
5.使⽤完后,将笔头清洗⼲净,并甩⼲或擦⼲笔头上的⽔,将笔帽盖回,关闭电源
更换电池
取下电池仓盖,拿出仓盖内旧电池,更换新的电池(如图四所⽰)。
Specifications - Installation and Operating InstructionsBulletin TE-WSM-10- C or F is the unit of the liquid temperature.- is the battery low icon.KeypadOperation1. Remove the probe cover from the meter to expose the electrode.2. Press to power on the meter. The LCD will display parameters (ex: tnr, tCo, tds,rAn) in turns and then it will enter normal display.accuracy. Alternatively, you can manually select the ranges. For example, if you prefer the meter to display a reading such as .50 mS instead of 500 uS, you press for more than 2 seconds.measurement mode. When the reading is stable, the unit will stop flashing.10. Press to freeze current readings. The text “Hold” will appear on the LCD. Pressagain to release.11. Turn off the meter by pressing .12. Make sure your electrode is clean and store it carefully. Before storage, rinse itcarefully in de-ionized water and store dry with the cap. Remember the storage temperature limits. For more information, see the maintenance section.13. Air bubbles can easily adhere around the gap between the electrode and theTo disable the auto power off:Before power on, press + simultaneously until an “n” appears on the screen. Then, release the keys to return to normal mode.The advanced setup mode lets you customize your meter’s preferences and defaults. To change the parameters, you can press for more than 2 seconds. You will enter setup mode when the meter is in measurement mode.1. When the meter is in measurement mode, press f for more than 2 seconds toenter setup mode.2. Press , , or to select P1.0.3. Press momentarily again to enter unit setting.4. Press or to select C or F.5. Press momentarily to confirm the unit, or press it for more than 2 seconds toreturn to P1.0 without saving.6. While in P1.0, press for more than 2 seconds to return to measurement mode. P3.0 Reset Meter (rSt)When you decide to reset the meter, all parameters will be reset to factory default values, including the calibration information.1. In P3.0, press momentarily to enter P3.1.2. Press or to select Y or N.3. Press momentarily to confirm the state and return to P3.0, or press it for morethan 2 seconds to return to P3.0 without confirming the P3.1 value.P4.0 Review Calibration Information (CAL)In P3.0, press or to select P4.0.P4.1 Range 1 Calibration Informationpress momentarilyconcentration. If the meter is not yet calibrated, “---”will display on the LCD.In P4.1 or P4.2, press momentarily to confirm the state and return to P4.0. In P1.0, P2.0, P3.0, P4.0, you can press for more than 2 seconds to return to1. Turn off the meter and stay in normal measurement mode.2. Press or for more than 2 seconds to select the range.(Default)temperature.7. Press for more than 2 seconds to begin the calibration. The SALT value willblink on the LCD.8. Press the or to adjust the value to match the value to the calibrationstandard. You can adjust the SALT reading up to ±30% from the detected value.9. When the “CAL” stops blinking, you can press to confirm the value. The meterwill switch back to SALT measurement mode. If “CAL” always blinks, check theThe text P1.1, P1.2, P1.3, P2.1, P3.1 will not displayLCD.NOTICE。
笔式PH测试笔使用说明及注意事项PH仪器操作步骤(1)拔下笔式PH计的PH电极帽,将pH复合电极在纯水中搅动洗净并甩干。
按键仪器通电,仪器经几秒钟自我诊断(显示SELFCAL)后液晶屏显示pH单位符号,表示进入测试状态。
(2)将pH电极浸入pH7.00校正溶液中,稍加晃动后静止放置数秒钟,待显示值稳定后按住键2秒钟,液晶屏会显示CAL符号,然后闪烁7.00字符,几秒钟后校准完成时,液晶屏先显示SR符号再显示END符号,并返回正常显示模式。
此时,液晶屏左下角会显示?符号,表示pH7.00校准完成并被芯片记忆。
(3)将pH电极在纯水中洗净并甩干,浸入pH4.00校正溶液中,稍加晃动后静止放置数秒钟,待显示值稳定后按住键2秒钟,液晶屏会显示CAL符号,然后闪烁4.00字符,几秒钟后校准完成时,液晶屏先显示SR符号再显示END符号,并返回正常显示模式。
此时,液晶屏左下角会显示?符号,表示pH4.00校准完成并被芯片记忆。
(4)将pH电极在纯水中洗净并甩干,浸入pH10.01校正溶液中,稍加晃动后静止放置数秒钟,待显示值稳定后按住键2秒钟,液晶屏会显示CAL符号,然后闪烁10.00字符,几秒钟后校准完成时,液晶屏先显示SR符号再显示END符号,并返回正常显示模式。
此时,液晶屏左下角会显示?符号,表示pH10.01校准完成并被芯片记忆。
(5)被测溶液测定将pH电极在纯水中洗净并甩干,浸入被测溶液中,稍加晃动后静止放置,待数字稳定后即可读数,就是该被测溶液的pH值。
4.2. 使用注意事项(1)防水型笔式pH计可以采用二点校准或三点校准,首先要校准7.00pH,然后根据被测溶液的pH值和精度要求,再校准4.00pH或10.01pH,如果选择三点校准,则在全量程范围内可以得到最精确的读数。
自动校准时,仪器会自动识别校准溶液,但如果标准溶液不准确,会使校准出现误差;如果校准溶液大于或小于标准值(4.00、7.00或10.01)1个pH值,仪器会显示CAL和END符号,表示无法校准。
TDS笔(测水笔)说明书1.在测试TDS值或电导率时可根据不同需要自动锁定读数或手动锁定读数;2. 采用低功耗背光,便于夜间和光线暗的地方进行测试使用.性能指示:1.检测项目:水质TDS值ppm(mg/L),电导率μs/cm,摄氏温度℃,华氏温度℉。
2..基本功能:●开关按钮(ON/OFF/HOLD)功能:开机:在关机状态下,按动本按钮,即可开机。
自动关机:使用后60s无操作则自动关机。
手动关机:持续按下ON/OFF/HOLD按钮3s关机。
手动锁定: 在TDS值较大或者水液温度变化自动锁定读数难以实现时,按HOLE键可手动锁定读数.锁定时,其对应物理量单位符号闪动。
●功能选择按钮(MODE):开机默认显示测试水质总固体溶解量值ppm;按一次本功能键,显示测试水质电导率μs/cm值,再按一次显示摄氏温度℃,再按一次,显示华氏温度℉;再按重复循环显示上述内容。
●CLEAR键功能:清零。
清除锁定读数,重新进行测试。
●自动测试和锁定读数:清零后插入水中即可自动读数,根据水质不同显示出对应TDS值或者电导率μs/cm 值。
然后自动锁定。
读数锁定状态下其对应单位符号闪动。
●刻度功能:按国家标准刻度。
并适当参照国际使用惯例。
直饮水警示参照国际标准采用TDS=40ppm作分界线。
低于40显示绿背光,为合格直饮水,大于40显示红背光,为非直饮水。
●背光功能:采用低功耗背光,便于夜间和光线暗的地方进行测试使用。
同时可作为直饮水判别显示。
●手动调整:具有手动调整功能,便于出厂和校正时调校。
●大屏幕液晶显示:采用高扭曲STN薄型全透液晶屏,显示出4位数值和对应物理量单位。
TDS读数范围:0~9999,标志符;溢出,显示Err。
●供3. 测试范围:TDS:0~9999ppm。
4. 解析度:<1000,1ppm;≥1000,10ppm;自动换档。
5. 测试精度:±2%。
6. 温度测试范围:0~99℃(华氏度为32~212℉),精度±0.1℃。
Specifications - Installation and Operating InstructionsBulletin TE-TDS2-10SPECIFICATIONSWetted Materials:ABS plastic and 316 SS.Range:Conductivity: 0 to 1999 uS or 0 to 19.99 mS;TDS: 0 to 1999 ppm or 0 to 19.99 ppt.Accuracy: ±1% FS.Display: 30(H) x 18(W) mm LCD dual display.Resolution:Conductivity: 1uS or .01 mS;TDS: 1 ppm or .01 ppt.Temperature Range: 32 to 122°F (0 to 50°C).Power Requirements: 4 LR44 batteries, 1.5 V ea.Enclosure Rating:IP65.Weight:4.3 oz (115 g).Agency Approval: CE.instrument.- C or F is the unit of the liquid temperature.- is the battery low icon.Keypad1. Remove the probe cover from the meter to expose the electrode.2. Press to power on the meter. The LCD will display parameters (ex: tnr, tCo, tds,rAn) in turns and then it will enter normal display.3. The meter is default in auto-ranging status once powered on. Auto-rangingyou prefer the meter to display a reading such as .50 mS instead of 500 uS, you press for more than 2 seconds.measurement mode. When the reading is stable, the unit will stop flashing.10. Press to freeze current readings. The text “Hold” will appear on the LCD. Pressagain to release.11. Turn off the meter by pressing .12. Make sure your electrode is clean and store it carefully. Before storage, rinse it To disable the auto power off:Before power on, press + simultaneously until an “n” appears on the screen. Then, release the keys to return to normal mode.The advanced setup mode lets you customize your meter’s preferences and defaults. To change the parameters, you can press for more than 2 seconds. You will enter setup mode when the meter is in measurement mode.1. When the meter is in measurement mode, press f for more than 2 seconds toenter setup mode.2. Press , , or to select P1.0.3. Press momentarily again to enter unit setting.4. Press or to select C or F.5. Press momentarily to confirm the unit, or press it for more than 2 seconds toreturn to P1.0 without saving.6. While in P1.0, press for more than 2 seconds to return to measurement mode.1. In P3.0, press momentarily to enter P3.1.2. Press or to select Y or N.3. Press momentarily to confirm the state and return to P3.0, or press it for morethan 2 seconds to return to P3.0 without confirming the P3.1 value.P4.0 Review Calibration Information (CAL)In P3.0, press or to select P4.0.P4.1 Range 1 Calibration Informationpress momentarilyconcentration. If the meter is not yet calibrated, “---”will display on the LCD.In P4.1 or P4.2, press momentarily to confirm the state and return to P4.0. In P1.0, P2.0, P3.0, P4.0, you can press for more than 2 seconds to return to1. Turn off the meter and stay in normal measurement mode.2. Press or for more than 2 seconds to select the range.temperature.7. Press for more than 2 seconds to begin the calibration. The conductivity andTDS value will blink on the LCD.8. Press the or to adjust the value to match the value to the calibrationstandard. You can adjust the conductivity or TDS reading up to ±30% from the 9. When the “CAL” stops blinking, you can press to confirm the value. The meterwill switch back to conductivity and TDS measurement mode. If “CAL” always©Copyright 2012 Dwyer Instruments, Inc.Printed in U.S.A. 6/12FR#R6-444017-00 Rev. 1 DWYER INSTRUMENTS, INC. Phone: 219/P.O. BOX 373 • MICHIGAN CITY, INDIANA 46360, U.S.A. Fax: 219/872-9057e-mail:*******************。
科尔康水质检测笔使用说明书
操作方法:以科尔康水质检测笔为例,将笔插入水中,点击笔身上的按键即可显示水质,可以显示TDS值,水中的杂杂质一般包括可溶性盐类、离子型有机物、重金属离子。
设备使用注意事项:1、如果科尔康水质检测笔显示的数值为0-50,表示水的纯度很高,50-100表示纯度较高,100-300表示纯度一般,300-600表示烧水时会出现水垢,600-1000表示水的口感较差,1000以上表示不适合饮用。
2、科尔康水质检测笔无法使用,可能是电量耗尽,可以更换电池。
3、科尔康水质检测笔采用低功耗芯片,两分钟不使用,可以自动关闭。
4、科尔康水质检测笔防水等级为IPx6,设备使用防腐蚀探针。
水质检测笔的使用方法一、水质检测笔的简介水质检测笔是一种便携式的水质检测设备,能够快速、准确地测量水体的PH值、溶解氧、电导率等关键指标,以评估水质的优劣。
其使用简单、操作便捷,可以广泛应用于家庭、学校、实验室等不同场合,帮助人们了解水质情况,保障饮用水安全。
二、准备工作在使用水质检测笔之前,需要进行一些准备工作,以确保测试结果的准确性和可靠性。
首先,需要确认水质检测笔的电池是否已经安装好,并确保电池电量充足。
其次,需要准备一些标准溶液,用于校准水质检测笔。
校准是保证测试结果准确性的关键步骤,因此一定要认真进行。
三、校准水质检测笔1. 校准PH值:a. 将水质检测笔放入PH 7标准溶液中,等待数秒钟,直到笔尖指示稳定。
b. 按下校准键,直到屏幕上显示7.0。
c. 将水质检测笔清洗干净,然后将其放入PH 4或PH 10标准溶液中,重复上述步骤,校准PH 4或PH 10值。
2. 校准溶解氧:a. 将水质检测笔放入空气中,等待数秒钟,直到笔尖指示稳定。
b. 按下校准键,直到屏幕上显示100%。
c. 将水质检测笔放入已知溶解氧含量的标准溶液中,按照溶液的使用说明进行校准。
3. 校准电导率:a. 将水质检测笔放入纯净水中,等待数秒钟,直到笔尖指示稳定。
b. 按下校准键,直到屏幕上显示电导率为纯净水的电导率。
c. 将水质检测笔放入已知电导率的标准溶液中,按照溶液的使用说明进行校准。
四、测试水质校准完成后,可以开始测试水质了。
使用水质检测笔进行水质测试的步骤如下:1. 打开水质检测笔的电源开关,等待数秒钟,直到笔尖指示稳定。
2. 将水质检测笔的笔尖浸入待测试的水体中,确保笔尖完全浸入水中。
3. 等待数秒钟,直到笔尖指示稳定,读取屏幕上显示的测试结果。
4. 根据需要,可以记录测试结果或进行其他操作。
五、注意事项在使用水质检测笔过程中,需要注意以下事项,以保证测试结果的准确性和可靠性:1. 在测试前,确保水质检测笔的笔尖干净,无污染物附着。
水质检测笔的使用方法随着环境污染问题的日益严重,人们对水质的关注度也越来越高。
为了方便大众能够及时了解水质情况,市场上出现了一种方便易用的水质检测笔。
本文将介绍水质检测笔的使用方法,以帮助大家更好地利用这一工具进行水质检测。
一、准备工作使用水质检测笔前,首先需要准备一些必要的工具和材料。
除了水质检测笔本身外,还需要一杯清水、一块干净的布和一张记录表格。
确保这些工具和材料都是干净的,以免影响检测结果。
二、检测过程1. 浸泡水质检测笔将水质检测笔的探头部分浸泡于待检测的水中,确保探头完全浸泡。
一般情况下,探头上会有一个最低浸泡线,需要确保水位超过该线。
2. 等待显示结果根据水质检测笔的使用说明,等待一定的时间,让检测笔完成水质检测的过程。
待显示屏上出现结果后,可以进行下一步的分析和记录。
3. 分析检测结果水质检测笔的显示屏上会显示出一些水质参数的数值,比如水温、pH值、溶解氧含量等。
根据检测结果进行分析,判断水质是否合格。
如果数值超出了正常范围,可能表示水质存在问题,需要进一步的处理或采取相应的措施。
4. 记录检测结果使用记录表格将检测结果进行记录,包括检测时间、地点和具体的检测数值等信息。
这样可以方便后续的对比和分析,也可以帮助跟踪水质的变化情况。
5. 清洁和保养使用完毕后,将水质检测笔的探头部分取出,用清水冲洗干净。
然后用干净的布擦拭干净,确保没有水渍残留。
将水质检测笔存放在干燥通风的地方,避免受潮或受损。
三、注意事项1. 使用水质检测笔前,要确保手部干净,避免因为污染影响检测结果。
2. 注意水质检测笔的使用温度范围,避免在超出范围的温度下使用,以免影响使用寿命。
3. 平时要定期校准水质检测笔,以确保检测结果的准确性。
4. 注意水质检测笔的电池电量,及时更换电池以保证正常使用。
水质检测笔是一种方便易用的工具,能够帮助我们实时了解水质情况。
通过正确使用水质检测笔,并根据检测结果进行分析和处理,可以保障我们的用水安全。
酸碱度水质检测笔的使用方法
使用酸碱度水质检测笔(pH测试笔)是相对简单的,以下是一般的使用方法:
1.准备工作:检查酸碱度水质检测笔的电极是否干净,如果有污垢或氧化物,可以轻轻擦拭清洁。
确保电极没有损坏或磨损。
2.标定((可选):如果使用新的检测笔或者长时间未使用,可以进行标定操作,以确保测量的准确性。
标定通常需要使用标准缓冲液,根据缓冲液的pH值进行调整。
3.获取水样:使用合适的容器获取待测水样。
确保水样足够覆盖检测笔的电极。
4.浸入水样:将酸碱度水质检测笔的电极部分浸入水样中,确保电极完全被浸泡。
5.等待稳定:等待一段时间,通常在几秒到一分钟之间,直到测量结果稳定。
这是因为电极需要与水样充分反应,直至达到平衡。
6.读取结果:检测笔上通常配备有数字显示屏,显示水样的pH值。
读取并记录显示屏上的结果。
7.清洁电极:使用清水冲洗检测笔的电极,确保去除水样残留物。
避免使用有害的溶剂或化学品清洁电极。
8.存储:根据设备的要求,将酸碱度水质检测笔存放在适当的环境中,避免阳光直射和高温。
需要注意的是,不同型号的酸碱度水质检测笔可能有略微不同的使用方法,因此在使用之前应仔细阅读设备的说明书。
此外,一些检测笔可能需要定期校准以确保准确性,根据具体型号的要求执行相应的维护步骤。
USER ’S INSTRUCTIONS使用说明书使用产品前请仔细阅读本使用说明书,并请妥善保管笔式电导率仪/TDS笔目录前言 (1)一、概述 (2)二、产品结构 (2)三、产品特点 (2)四、技术参数 (3)五、仪器安装 (3)六、仪器使用 (3)七、维护保养 (4)八、保修声明 (4)九、开箱检查 (5)十、装箱清单 (5)前言感谢您选择力辰科技笔式电导率仪/TDS笔,为获得更好的使用体验,请认真阅读本使用说明书,并遵守安全操作规范!请妥善保管本使用说明书以便需要时查阅!注意事项:请确保只有受过相关训练的人员才能操作使用本仪器。
请遵守安全规范、人身安全和事故防止等相关规范。
每次使用前请注意检查仪器和配件确保无损。
处理有毒介质时,请在合适的通风橱中进行。
校正仪器请尽量选择与待测液的测量值最接近的电导率/TDS值的标准溶液值,这样可以使测量结果更加精准。
本仪器需要定期的校正。
如果测量溶液的测量值是在中间范围,请每月至少校正一次。
在校正或测量之前,请浸润电极15分钟,可以湿润测量棒表面并清除附着在上面的杂志。
如果测量温度过高或过低,请每周校正一次,已确保准确度。
使用时请不要把仪器插入液体过深,只要液体能够没过铂黑电极即可。
使用前特别注意电极固定环是否松动,如果电极固定环松动,仪器使用过程中测试的液体可能会进入仪内部造成故障。
电导率仪/TDS笔的铂黑电极一定要在清洁、无损伤的条件下才能进行正常的测量,任何破损和擦毛都会使铂黑电极失效。
测量前和测量后都要用纯水清洗电极,以保证测量精度。
在粘稠性试样中测定后,电极需用纯水反复冲洗多次,以除去粘在测量棒上的试样,或先用适宜的溶济清洗,再用纯水洗去溶剂。
切记!请勿用物体擦拭铂黑电极,使用后用清水冲洗、晾干,并盖紧电极保护帽。
如长时间不用,请取出电池,将电导率仪/TDS笔放置在干燥、无尘、无腐蚀性气体环境中保存。
长期未使用的电导率仪/TDS笔的铂黑电极,使用前请在蒸馏水或去离子水中浸润30分钟以上。