Miller Electric Mfg. Co.An Illinois Tool Works Company 1635 West Spencer Street Appleton, WI 54914 USAWeb SiteInternational HeadquartersPhone: 920-735-4505USA FAX: 920-735-4134Canadian FAX: 920-735-4169International FAX: 920-735-4125The induction system is equipped with fault protection prevent accidental shock hazards. Operator and nearby welder burns are significantly less likely because connectors are not hot The induction power source is power efficient (more than 90%),reducing operating costs. Also,less heat is transferred to the outside air, improving the work environment.Induction heating provides uniform heating around the pipe and through thickness . The surface of the pipe is not marred by localized conducted heat at higher than specified temperatures.The induction system uses a simple to operate control with graphic guide to facilitate programming. Systems can be provided with or without recorder.Low input power , requires less amperage.conventional processes due to the method of applying the heat, reducing heat treat cycle time.300 pounds and has a small footprint. The unit can be easily moved.requires the wrapping of insulation over the pipe and thermocouples, followed by wrapping of the heating cable. This results in significantly less setup time and operator training.Induction Heating Systems5,20,25 kW Preheat and Post Weld Heat TreatmentInduction HeatingSystemIssued May 2002 • Index No. IN/8.0The Power of Blue ®.Durable induction coils reduce replacement and repair costs. The insulation is reusable used 50 times or more, reducing cost of disposal.The reliable systems are tested to the same require-ments as Miller welding equipment. In addition, the process is not subject to multiple heating units,where one unit could fail aborting the heat treat cycle.Flexibility is provided by induction coils that can be easily moved or adjusted.*Contact factory for other sizes.**Power source, coolant system and cart.25 kW System2System ComponentsIntellifire ™Power SourceIntellifire ™Power SourceThe Miller Intellifire ™units are inverter-based, solid-state, high-frequency induction heating power sources that provide infinite control over a range of 0 to 25 kW (0 to 20 kW for Intellifire 204). They combineflexibility, precision and reliability into compact lightweight packages that provide all the features required for reliable, consistent and efficient heating using the induction process. The 100%-duty-cycle, air-cooled units are perfect for heating operations —especially large diameter pipe,heavy wall steel plate and critical time-to-temperature applications.Intellifire ™204 (20 kW)/250 (25 kW)Power SourcesThe coolant system conveniently mounts under the power source.12,000 BTU/hour cooling capacity 2-1/2 gallon coolant tankTransformer provides power for power source, coolant system and controlsRustproof, polyethylene molding serves as coolant tank and easy-to-fill coolant spoutEfficient fin and tube heat exchanger “Paddle wheel” flow indicatorExternal filter can be quickly accessed for cleaningCoolant System and Portable CartIHPS ™5kW This inverter-based, solid-state, high-frequency induction heating power source provides infinite control over a range of 0 to 5 kW. It combines flexibility, precision and reliability into a compact lightweight package that provides all the features required for consistent and efficientinduction heating. The 5 kW, 100%-duty-cycle, air-cooled unit is perfect for heating operations —especially on medium-sized parts and less critical time-to-temperature applications.IHPS ™II 5KW Power SourceThe cooler is a compact, horizontal-design coolant system and is equipped with a power switch to turn the unit on and off at the front panel.14,000 BTU/hour cooling capacity 3 gal (11.4 L) coolant tankRustproof, polyethylene molding serves as the coolant tank, fan shroud,filler spout and lifting handlesCoolant filler spout and coolant filter are easy-to-access at the front panelEfficient fin and tube heat exchanger “Paddle wheel” flow indicator Panel-mounted on/off switchCoolant SystemSystems can be equipped with an for moving the system at a construction site.3System Components (Continued)Liquid-Cooled Heating CablesThe liquid-cooled heating cable provides the power to the part to be heated. The cableencloses a special copper conductor specifically designed for carrying high-frequency current to maximize efficiency. The cable also carries the coolant, which cools the conducting wire. The hose is reinforced for strength and durability. Preheat cable covers are available to protect the heating cable from slag and molten metal created during welding. The preheat covers are easy to installand can withstand temperatures up to 650˚ F.Power Extension CableThe cable is equipped with Twist-Lock quick disconnects for easy removal and attachment.Liquid-cooled extension cables are available to remote the power source up to 50 feet from thework. The cables are flexible for ease of use.The insulation is designed for maximumtemperature insulation, ease of use, durability and environmental friendliness.The insulation is designed to insulate the work for process efficiency and protect the liquid-cooled cable from high temperatures of stress relieving.The blankets are sized and stenciled for the pipe size to be treated.The insulation is sewn into a silica blanket,which provides high durability. 50 thermal cycles or more can be achieved with one blanket.The sewn blanket insulation does not create the dust and particulate associated with bulk insulation. This creates a friendlier environment for the heat-treaters and welders.InsulationThe IHTS Controller provides for simple to advanced thermal cycle programs. The control comes programmed with a typical thermal cycle for stress relief. This includes a step in temperature from ambient to criticaltemperature, controlled temperature rise to the holding temperature, a soak or dwell at stress relief temperature, a controlled cooling rate to critical temperature and air cool (see chart).The programming of the unit is facilitated with a graphical presentation of the heat cycle and corresponding controller program. The IHTS is equipped with a large run, hold and stop button for ease of use. The control also includes the coolant flow switch. This switch insures that proper coolant flow is being provided to the liquid-cooled heating cable. A coolant fault is indicated with a light on the face of the control.The IHTS Control is available in two configurations to meet your application requirements.1. The IHTS Control is available without a temperature recorder. In this way, you can use your existing recorders or purchase an alternative recorder of your choice. The unit is equipped with a blank panel, which can be removed to install a 100 mm recorder.2. The IHTS Control is available with a digital recorder. The recorder is built into the IHTS to provide six thermocouple inputs. The recorder is equipped with a touch-screen for simple programming and use. The color display permits clear monitoring of the heat treat process and provides alarms for process control. Data is stored on a floppy disc for printing, storage, or further analysis. The operating temperature range of the IHTS Recorder is 41˚ F to 104˚ F.Control without recorderControl with digital recorderIHTS Controller – RecorderDimensionsH: 10 in (254 mm)W: 11-3/4 in (298 mm)D: 14-1/2 in (368 mm)Shipping Dimensions:H: 15 in (381 mm)W: 16-3/4 in (425 mm)D: 20 in (508 mm)Ordering InformationEquipment and Options Stock No.Description Qty.Price5 kW Induction Base System#907 022(230 or 460 VAC, 3-phase) includes power source, cooler, and cart20 kW Induction Base System#907 097(400 VAC, 3-phase) includes power source, cooler, and cart25 kW Induction Base System#907 021(460 VAC, 3-phase) includes power source, cooler, and cartIHTS Temperature Controller#194 916Includes temperature controller, parameter display and flow switchIHTS Temperature Controller and Digital Recorder#194 916-01-1Includes temperature controller, parameter display, flow switchand digital (6 channel) temperature recorderLifting Eye Assembly#204 231For 20 kW and 25 kW systemsNote: Select a heating cable, an insulation blanket, and an extension cable from below to complete the system.Liquid-Cooled Induction Heating Cables#194 90930 ft#194 86740 ft#194 91050 ft#194 94360 ft#194 90770 ft#194 90880 ftPreheat Covers#204 61130 ft#204 61240 ft#204 61450 ft#204 61660 ft#204 61770 ft#204 62080 ftPWHT Insulation Blankets (1 in thick)#194 947For 2.5 in pipe (12" x 15")#194 948For 4 in pipe (12" x 21")#194 949For 6 in pipe (12" x 33")#194 950For 8 in pipe (18" x 39")#194 951For 10 in pipe (18" x 45")#194 952For 12 in pipe (18" x 50")#194 953For 14 in pipe (18" x 54")#194 954For 16 in pipe (18" x 58")#194 955For 18 in pipe (24" x 67")#194 956For 20 in pipe (24" x 73")#194 957For 22 in pipe (24" x 79")#194 958For 24 in pipe (24" x 85")#195 502For 26 in pipe (24" x 91")#194 998For 28 in pipe (24" x 98")#207 817For 30 in pipe (24" x 105")Preheat Insulation and Accessories#204 609Preheat insulation 1/2 in x 6 in x 89.5 in#204 669Preheat insulation, woven silica, 1/2 in x 6 in x 120 in#194 965Rope, high temperature, 1 in wide, 50 ft rollExtension Cables (Output Power) #194 89610 ft, liquid-cooled#194 89325 ft, liquid-cooled#194 89450 ft, liquid-cooledAccessoriesThermocouple Attachment Unit#194 959WelderThermocouple Cable (Type K)#194 999Type K thermocouple wire, 500 ftThermocouple Connector (Type K)#195 0982-pin male, package of 10Thermocouple Extension (Type K)#194 968Cable, 6 pair, 50 ftDate:Total Quoted Price:Distributed by:Litho in USA。
Eaton 274018Eaton Moeller series xPole - PFIM Type AC, A, U, R RCCB.Residual current circuit breaker (RCCB), 40A, 2p, 30mA, type G, AUGeneral specificationsEaton Moeller series xPole - PFIM Type AC, A, U, R RCCB274018401508274018480 mm 71 mm 35 mm 0.22 kg RoHS conform IEC/EN 61008PFIM-40/2/003-G-AUProduct NameCatalog NumberEANProduct Length/Depth Product Height Product Width Product Weight Compliances Certifications Model CodeTwo-poleShort time-delayed 40 A10 kA30 mAAC current sensitive Surge-proof, 3 kA 230 V AC230 V440 V4 kV0.03 A0.03 A50 Hz63 A (max. admissible back-up fuse) AC500 A25 A gG/gL10 kA3 kA196 V AC - 264 V AC24000 operationsApplicationNumber of polesTripping timeAmperage RatingRated short-circuit strength Fault current rating Sensitivity typeImpulse withstand current Type Voltage ratingRated operational voltage (Ue) - maxRated insulation voltage (Ui)Rated impulse withstand voltage (Uimp) Rated fault current - minRated fault current - maxFrequency ratingShort-circuit ratingLeakage current typeRated residual making and breaking capacity Admissible back-up fuse overload - max Rated short-time withstand current (Icw) Surge current capacityTest circuit rangePollution degreeLifespan, electricalResidual current circuit breaker for residential and commercial applications xPole - Switchgear for residential and commercial applicationsPFIMResidual current circuit breakersType G (ÖVE E 8601)45 mm235 mm (2 SU)70.5 mmDIN railQuick attachment with 2 latch positions for DIN-rail IEC/EN 60715IP20, IP40 with suitable enclosureIP20Open mouthed/lift terminals1.5 mm² - 35 mm²1.5 mm²35 mm²16 mm² (2x)1.5 mm²16 mm²Finger and hand touch safe, DGUV VS3, EN 502740.8 mm - 2 mm20000 operations-25 °C 40 A5.8 W-25 °C60 °CMeets the product standard's requirements.Meets the product standard's requirements.Meets the product standard's requirements.Meets the product standard's requirements.Meets the product standard's requirements.Does not apply, since the entire switchgear needs to be evaluated.Does not apply, since the entire switchgear needs to be evaluated.Meets the product standard's requirements.Does not apply, since the entire switchgear needs to be evaluated.Meets the product standard's requirements.Does not apply, since the entire switchgear needs to be evaluated.FrameWidth in number of modular spacingsBuilt-in width (number of units)Built-in depthMounting MethodDegree of protectionTerminals (top and bottom)Terminal capacity (solid wire)Connectable conductor cross section (solid-core) - min Connectable conductor cross section (solid-core) - max Terminal capacity (stranded cable)Connectable conductor cross section (multi-wired) - min Connectable conductor cross section (multi-wired) - max Terminal protectionBusbar material thicknessLifespan, mechanicalPermitted storage and transport temperature - min Rated operational current for specified heat dissipation (In) Equipment heat dissipation, current-dependentAmbient operating temperature - minAmbient operating temperature - max10.2.2 Corrosion resistance10.2.3.1 Verification of thermal stability of enclosures10.2.3.2 Verification of resistance of insulating materials to normal heat10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects10.2.4 Resistance to ultra-violet (UV) radiation10.2.5 Lifting10.2.6 Mechanical impact10.2.7 Inscriptions10.3 Degree of protection of assemblies10.4 Clearances and creepage distances10.5 Protection against electric shock60 °C25-55 °C / 90-95% relative humidity according to IEC 60068-2Does not apply, since the entire switchgear needs to be evaluated.Is the panel builder's responsibility.Is the panel builder's responsibility.Is the panel builder's responsibility.Is the panel builder's responsibility.Is the panel builder's responsibility.The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.Is the panel builder's responsibility. The specifications for the switchgear must be observed.Is the panel builder's responsibility. The specifications for the switchgear must be observed.The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.Z-HK 248432Additional equipment possible Residual current circuit breakerInterlocking deviceShort-time delayed tripping eaton-rcd-application-guide-br019003en-en-us.pdfeaton-xpole-pfim-u-rccb-catalog-ca019028en-en-us.pdf eaton-xpole-pfim-x-rccb-catalog-ca019029en-en-us.pdfDA-DC-03_PFIIL019140ZUPermitted storage and transport temperature - maxClimatic proofing10.6 Incorporation of switching devices and components10.7 Internal electrical circuits and connections10.8 Connections for external conductors10.9.2 Power-frequency electric strength10.9.3 Impulse withstand voltage10.9.4 Testing of enclosures made of insulating material10.10 Temperature rise10.11 Short-circuit rating10.12 Electromagnetic compatibility10.13 Mechanical functionAccessories required FeaturesFitted with: FunctionsSpecial features Application notes Catalogues Certification reports Installation instructionsEaton Corporation plc Eaton House30 Pembroke Road Dublin 4, Ireland © 2023 Eaton. All rights reserved. Eaton is a registered trademark.All other trademarks areproperty of their respectiveowners./socialmediaKLV-TC-2 276240 (Compact enclosure)Z-FW/LP 248296 (Remote control and automatic switching device)Z-RC/AK-2MU 285385 (sealing cover set)Used withCurrent test marks as per inscriptionMaximum operating temperature is 60 °C: Starting at 40 °C, the max. permissible continuous current decreases by 2.5% for every 1 °CTripping signal contact for subsequent installation Z-NHK 248434。
德国EMG-DREHMO电动执行器选型手册选型建议选择合适、正确的执行器,我们建议一般遵循如下原则:1.按照执行器控制对象的运动轨迹选择相应输出形式的执行器多转式型:输出轴的转动必须大于2圈,才能完成被控对象的全行程。
适用于各类闸阀、截止阀和滑板阀等。
部分回转型:输出轴的转动小于360°(通常为0-90°也可提供特殊行程如120°或180°),就可完成被控对象的全行程。
适用于蝶阀、球阀、风门挡板和百叶阀等。
直线型:输出轴的运动为直线运动(而不是转动),适用于需要直线推力动作的阀门,如调节阀等。
2.根据驱使被控对象所需要的力矩,选择相应型号执行器。
多转式:10-16000Nm部分回转型:开关型10-80000Nm,调节型10-40000Nm直线型:5-217KN3.根据控制要求选择相应的控制方式,不同控制方式对应不同接线图。
4.根据工矿环境选择安装方式及安装尺寸。
5.根据特殊的工矿要求,选择相应参数。
订货须知示例:输入、输出4-20mADC信号;002表示输入接点量信号,输出接点量信号;003表示输入接点信号,输出4-20mADC和接点量信号。
调节型执行器(S则表示开关型执行器)支架拐臂式连接,型号中无FHA则为直连式连接方式。
输出额定力矩=300X10Nm蜗轮、蜗杆减速箱用于部分回转型多转式执行器输出力矩60NM(末位为0其数值表示输出力矩值,末位为9其数值需要加1表示输出力矩值)本机带MATIC系列控制箱产品电动多转式执行器目录1.技术参数1.1多转式执行器1.1.1小扭矩多转式1.1.2大扭矩多转式1.2部分回转执行器1.2.1开关型D(MC)+MSG系列1.2.2调节型D(MC)+MSG-R系列1.2.3DP(MC)系列1.3直线型执行器1.4电机数据1.4.1D(MC)系列1.4.2DP(MC)系列2.外形、输出连接尺寸2.1多转式执行器2.1.1小扭矩多转式2.1.2大扭矩多转式2.2部分回转型执行器2.2.1直连式2.2.1.1开关型D(MC)+MSG系列2.2.1.2调节型D(MC)+MSG系列2.2.2底座曲柄式2.2.2.1开关型D(MC)+MSG系列2.2.2.2调节型D(MC)+MSG系列2.2.3DP(MC)系列2.2.3.1外形尺寸2.2.3.2输出连接尺寸2.3直线型执行器2.3.1外形尺寸及连接尺寸3.控制方式(典型接线图)3.1STANDARD控制(不带控制箱)3.2Matic C控制3.2.1MC0023.2.2MC0033.2.3MC0053.3控制原理图3.3.1标准型3.3.2MC0023.3.3MC0033.3.4MC0051.技术参数1.1多转式执行器多转式电动执行器是所有执行器的基础。