Cleaning Validation ProtocolDevice name: XXXX Model: XXXXTest parts: XXXXPrepared by:Title: Management representative1. General informationAudited by:Title: RA EngineerProtocol No.: XXX-01Sponsor: XXXX Limited.Add: XXXX China.Test director: XXXTest personal : XXXTest objective: Validate the efficacy of cleaning method (manual cleaning) provided in user manual for XXXX. Test sample: XXXX, see table 1Test Lab: XXXX LimitedReference:AAMI TIR12:2010 Designing, Testing, and Labeling Reusable Medical Devices for Reprocessing in Health Care Facilities. A Guide for Device Manufacturers 1st ed.AAMI TIR30:2011 A Compendium of Processes, Materials, Test Methods, and Acceptance Criteria for Cleaning Reusable Medical Devices.Alfa MJ, Degagne P, Olson N. Worst-case soiling levels for patient used flexible endoscopes before and after cleaning. Am J Infect Control 1999;27:392-401.ASTM D7225-13 Standard Guide for Blood Cleaning Efficiency of Detergents and Washer-disinfectorsReprocessing Medical Devices in Health Care Settings: Validation Methods and Labeling Guidance for Industry and Food and Drug Administration Staff. March 17, 2015User manual of XXXX2.IntroductionThis protocol details the methods to be used to validate the effectiveness of a manual cleaning procedure for the XXXX.The device will be inoculated with an artificial test soil in various areas including those considered to be most challenging to clean and most likely to be soiled during actual use. The device then will be processed in accordance with the cleaning procedure delineated in section 5. the device will be assayed and residual blood will be recovered to determine if adequate cleaning was achieved.This testing will be repeated for a total of three (3) test cycles.3.JUSTIFICATIONThis test method was based on methods outlined in AAMI TIR30:2011 and ASTM D7225-13 .Cleaning instructions for reusable medical devices require validation in order to assure proper and safe reprocessing of the devices by healthcare facilities. It is well known that a device which has not been cleaned properly may inhibit the ability of the sterilization process to achieve the proper sterility assurance level. This cleaning procedure must be able to remove gross amounts of soil from the test device in order for it to be determined clean and safe for further processing. This study will attempt to verify that gross amounts of soil can be removed from the device following the recommended cleaning procedure.The artificial test soil used to inoculate the device will simulate worst case contaminants (blood and human saliva) that may come in contact with the device and remain on the device after clinical use. The device will be soiled using the artificial test soil and inoculated in the most difficult to clean locations and areas most likely to be soiled during actual use. The least effective (lowest) cleaning temperatures (according to the using temperature) within recommendations etc. These procedures will provide worst case soiling conditions for the cleaning validation.Acceptance criteria : no obvious stain under visual Observation, and will be based on study data of residual blood levels of properly cleaned medical instruments which indicate that after cleaning, the level of blood < 0.1 g/deviceon the device after performing the recommended cleaning procedure will indicate adequate cleaning and demonstrate that the cleaning method is efficacious in removing soil .4.EQUIPMENT AND MATERIALS1)XXXX: XXXX2)Detergent: 75% alcohol3)Rabbit blood4)Human saliva5)Solution 1--0.1%Tetramethylbenzidine (TMB) in 5% acetic acid, solution 2--3% hydrogen peroxidesolution, used for blood Analysis6)Swab7)Timer8)Thermometer9)Soft cloth10)soft brush5.Cleaning5.1Preparation of artificial test soilThe artificial test soil will contain the following components to mimic blood and saliva:2.5 ml rabbit blood2.5 ml physiological saline5 ml human saliva5.2Cleaning validation Procedure1)The devices listed in Table 1 will be obtained. See Table 2 for testing sample sizes.2)Prior to testing, all devices will be pre-cleaned following steps 5).3)The test samples will be inoculated in the most difficult to clean locations and areas most likely to be soiledduring actual use with the prepared artificial test soil, see Figure 1 for the device inoculation description.4)The inoculated test samples will be allowed to dry at room temperature for a minimum of two (2) hours tosimulate worst case conditions. A photo of the soiled devices will be included in the final report.5)Head cleaning (for Each test sample and negative control):a.Remove dirt and debris from the water spray outlets with a soft brush,b.Fill a cup halfway with clean water,c.Activate the XXXX and immerse into water whilst bur is rotating,d.Start and stop rotating the bur for 2 to 3 seconds 3 times whilst the head remains in the water. Remove andwipe dry with a clean soft cloth.XXXX cleaning(for Each test sample and negative control)a.Rinse the device under running cold tap water and hand wash the full surface of the device until no obviousdirty.b.Wipe the device with a water soaked soft cloth.c.Wipe clean with alcohol-immersed cotton swab or cloth, ensuring contact with difficult to clean areas suchas chuck holes,crevices etc.6)The test samples and negative control will be visually inspected. If visual soil remains, steps 5) will be repeateduntil test devices are visibly clean.7)Steps 3) through 6) will be repeated three additional times for a total of four repetitive inoculation and cleaningcycles to simulate soil accumulation that might occur during actual use.8)Steps 3) and 4) will be repeated for the positive control.9)Sample the whole XXXX surface with swab, especially the areas difficult to clean, such as chuck holes,crevicesetc. (Use the clean cotton swab that does not react with the test solution. If surfaces are dry, swab should be moistened with a drop of water. If the surface is wet, the swab need not be pre-moistened)10)Activate 1 ml of solution1 with 100 l of solution 2 and drop the swab in the liquid. Blood residue will beindicated by a blue color reaction. Visible color change will occur at 0.1 g or greater. Repeated the step 9) through 10) until get all results of these samples.11)Results, equipment, lot numbers, and other pertinent information will be record and issued in the final report.Device soiling descriptions:Figure 1Using gloved hands soiled with artificial test soil, the surface of the device will be handled, ensuring contact with difficult clean areas such as chuck hole,crevices .6.0 Acceptance Criteria6.1 Each test sample shall be free of visible soil after cleaning.6.2Each test sample shall produce a blood level of less than 0.1 g/device after cleaning.5.0 Final ReportThe test report shall include but not limited: name and address of test institution, name of test personnel, start and end time, description of the test sample, test methods, observations, as well as the results of other necessary information, etc.。
FDA清洗验证检查指南I.引言自FDA各种文件(包括化学原料药检查指南、生物技术检查指南)首次提出这个问题之后,清洗过程的验证已经引发了很多讨论。
FDA的文件明确指出要求对清洗过程进行验证。
本指南讨论了各种可接受(或不可接受)的验证方法,从而使FDA的检查具有一致性。
但必须清楚地认识到:与其他工艺验证一样,清洗验证方法也不止一种。
所有过程验证的检查标准是:检查其科学数据能否证明系统稳定一致地达到预期目的,系统结果稳定地符合预先制定的标准。
本指南仅适用于设备化学残留物的清洗验证。
II.背景对于FDA而言,使用设备前进行清洗不是什么新要求。
1963年GMP法(133.4)规定“设备应处于清洁、有序的状态”。
1978年的cGMP中规定了设备清洗的章节(211.67)。
要求清洗设备的主要目的还是防止污染或混料。
由于设备清洗维护不当或防尘管理不当,FDA检查官曾十分注意检查卫生状况。
过去FDA总是更注意检查青霉素类与非青霉素类药物之间的交叉污染、药品与甾类物质或激素之间的交叉污染问题。
在过去二十年间,因实际或潜在的青霉素交叉污染问题已从市场上撤回了大量的药品。
另一个事件使FDA对交叉污染问题日益重视,即1988年从市场上撤回了消胆胺成品制剂,原因是规程不当。
生产该制剂的原料药受到了农业杀虫剂生产中少量中间体和降解物质的污染。
造成交叉污染的主要原因使用了回收溶媒。
而回收溶媒受到了污染,原因是对溶媒桶的重复使用缺少监控。
贮存杀虫剂产生的回收溶媒桶又重复地用于贮存该药品生产中的回收溶媒。
而工厂没有对这些溶媒桶进行有效的监控,没有对其中的溶媒进行有效的检验,也没有对桶的清洗规程进行验证。
被杀虫剂污染的部份化学原料药运到了另一地点的第二家工厂生产制剂,使该工厂的流化床干燥器中物料袋受到了杀虫剂的污染,料造成各批产品受到污染,而该工厂根本就没有生产杀虫剂。
1992年,FDA对一家海外原料药生产厂发出了进口警告,该工厂使用同一设备生产强力甾类物质和非甾类物质。
Validation of Cleaning Processes (7/93)GUIDE TO INSPECTIONS VALIDATION OF CLEANING PROCESSESNote: This document is reference material for investigators and other FDA personnel. The document does not bind FDA, and does no confer any rights, privileges, benefits, or immunities for or on any person(s).I. INTRODUCTIONValidation of cleaning procedures has generated considerable discussion since agency documents, including the Inspection Guide for Bulk Pharmaceutical Chemicals and the Biotechnology Inspection Guide, have briefly addressed this issue. These Agency documents clearly establish the expectation that cleaning procedures (processes) be validated.This guide is designed to establish inspection consistency and uniformity by discussing practices that have been found acceptable (or unacceptable). Simultaneously, one must recognize that for cleaning validation, as with validation of other processes, there may be more than one way to validate a process. In the end, the test of any validation process is whether scientific data shows that the system consistently does as expected and produces a result that consistently meets predetermined specifications.This guide is intended to cover equipment cleaning for chemical residues only.II. BACKGROUNDFor FDA to require that equipment be clean prior to use is nothing new, the 1963 GMP Regulations (Part 133.4) stated as follows "Equipment *** shall be maintained in a clean and orderly manner ***." A very similar section on equipment cleaning (211.67) was included in the 1978 CGMP regulations. Of course, the main rationale for requiring clean equipment is to prevent contamination or adulteration of drug products. Historically, FDA investigators have looked for gross insanitation due to inadequate cleaning and maintenance of equipment and/or poor dust control systems. Also, historically speaking, FDA was more concerned about the contamination of nonpenicillin drug products with penicillinsor the cross-contamination of drug products with potent steroids or hormones. A number of products have been recalled over the past decade due to actual or potential penicillin cross-contamination.One event which increased FDA awareness of the potential for cross contamination due to inadequate procedures was the 1988 recall of a finished drug product, Cholestyramine Resin USP. The bulk pharmaceutical chemical used to produce the product had become contaminated with low levels of intermediates and degradants from the production of agricultural pesticides. The cross-contamination in that case is believed to have been due to the reuse of recovered solvents. The recovered solvents had been contaminated because of a lack of control over the reuse of solvent drums. Drums that had been used to store recovered solvents from a pesticide production process were later used to store recovered solvents used for the resin manufacturing process. The firm did not have adequate controls over these solvent drums, did not do adequate testing of drummed solvents, and did not have validated cleaning procedures for the drums.Some shipments of this pesticide contaminated bulk pharmaceutical were supplied to a second facility at a different location for finishing. This resulted in the contamination of the bags used in that facility's fluid bed dryers with pesticide contamination. This in turn led to cross contamination of lots produced at that site, a site where no pesticides were normally produced.FDA instituted an import alert in 1992 on a foreign bulk pharmaceutical manufacturer which manufactured potent steroid products as well as non-steroidal products using common equipment. This firm was a multi-use bulk pharmaceutical facility. FDA considered the potential forcross-contamination to be significant and to pose a serious health risk to the public. The firm had only recently started a cleaning validation program at the time of the inspection and it was considered inadequate by FDA. One of the reasons it was considered inadequate was that the firm was only looking for evidence of the absence of the previous compound. The firm had evidence, from TLC tests on the rinse water, of the presence of residues of reaction byproducts and degradants from the previous process.III. GENERAL REQUIREMENTSFDA expects firms to have written procedures (SOP's) detailing the cleaning processes used for various pieces of equipment. If firms have one cleaning process for cleaning between different batches of the same product and use a different process for cleaning between product changes, we expect the written procedures to address these different scenario.Similarly, if firms have one process for removing water soluble residues and another process for non-water soluble residues, the written procedure should address both scenarios and make it clear when a given procedure is to be followed. Bulk pharmaceutical firms may decide to dedicate certain equipment for certain chemical manufacturing process steps that produce tarry or gummy residues that are difficult to remove from the equipment. Fluid bed dryer bags are another example of equipment that is difficult to clean and is often dedicated to a specific product. Any residues from the cleaning process itself (detergents, solvents, etc.) also have to be removed from the equipment.FDA expects firms to have written general procedures on how cleaning processes will be validated.FDA expects the general validation procedures to address who is responsible for performing and approving the validation study, the acceptance criteria, and when revalidation will be required.FDA expects firms to prepare specific written validation protocols in advance for the studies to be performed on each manufacturing system or piece of equipment which should address such issues as sampling procedures, and analytical methods to be used including the sensitivity of those methods.FDA expects firms to conduct the validation studies in accordance with the protocols and to document the results of studies.FDA expects a final validation report which is approved by management and which states whether or not the cleaning process is valid. The data should support a conclusion that residues have been reduced to an "acceptable level."IV. EVALUATION OF CLEANING VALIDATIONThe first step is to focus on the objective of the validation process, and we have seen that some companies have failed to develop such objectives. It is not unusual to see manufacturers use extensive sampling and testing programs following the cleaning process without ever really evaluating the effectiveness of the steps used to clean the equipment. Several questions need to be addressed when evaluating the cleaning process. For example, at what point does a piece of equipment or system become clean?(何种情况下1台设备或系统已经被清洁干净?)Does it have to be scrubbed by hand?(需要用手工来擦洗吗?) What is accomplished by hand scrubbing rather than just a solvent wash?(哪些是手工擦洗完成,而不是溶剂清洗完成的?)How variable are manual cleaning processes from batch to batchand product to product?(产品之间和批之间的手工清洁如何不同?) The answers to these questions are obviously important to the inspection and evaluation of the cleaning process since one must determine the overall effectiveness of the process. Answers to these questions may also identify steps that can be eliminated for more effective measures and result in resource savings for the company.Determine the number of cleaning processes for each piece of equipment. Ideally, a piece of equipment or system will have one process for cleaning, however this will depend on the products being produced and whether the cleanup occurs between batches of the same product (as in a large campaign) or between batches of different products. When the cleaning process is used only between batches of the same product (or different lots of the same intermediate in a bulk process) the firm need only meet a criteria of, "visibly clean" for the equipment. Such between batch cleaning processes do not require validation.1. Equipment DesignExamine the design of equipment, particularly in those large systems that may employ semi-automatic or fully automatic clean-in-place (CIP) systems since they represent significant concern. For example, sanitary type piping without ball valves should be used. When such nonsanitary ball valves are used, as is common in the bulk drug industry, the cleaning process is more difficult.When such systems are identified, it is important that operators performing cleaning operations be aware of problems and have special training in cleaning these systems and valves. Determine whether the cleaning operators have knowledge of these systems and the level of training and experience in cleaning these systems. Also check the written and validated cleaning process to determine if these systems have been properly identified and validated.In larger systems, such as those employing long transfer lines or piping, check the flow charts and piping diagrams for the identification of valves and written cleaning procedures. Piping and valves should be tagged and easily identifiable by the operator performing the cleaning function. Sometimes, inadequately identified valves, both on prints and physically, have led to incorrect cleaning practices.Always check for the presence of an often critical element in the documentation of the cleaning processes; identifying and controlling the length of time between the end of processing and each cleaning step. This is especially important for topicals, suspensions, and bulk drugoperations. In such operations, the drying of residues will directly affect the efficiency of a cleaning process.Whether or not CIP systems are used for cleaning of processing equipment, microbiological aspects of equipment cleaning should be considered. This consists largely of preventive measures rather than removal of contamination once it has occurred. There should be some evidence that routine cleaning and storage of equipment does not allow microbial proliferation. For example, equipment should be dried before storage, and under no circumstances should stagnant water be allowed to remain in equipment subsequent to cleaning operations.Subsequent to the cleaning process, equipment may be subjected to sterilization or sanitization procedures where such equipment is used for sterile processing, or for nonsterile processing where the products may support microbial growth. While such sterilization or sanitization procedures are beyond the scope of this guide, it is important to note that control of the bioburden through adequate cleaning and storage of equipment is important to ensure that subsequent sterilization or sanitization procedures achieve the necessary assurance of sterility. This is also particularly important from the standpoint of the control of pyrogens in sterile processing since equipment sterilization processes may not be adequate to achieve significant inactivation or removal of pyrogens.2. Cleaning Process WrittenProcedure and DocumentationExamine the detail and specificity of the procedure for the (cleaning) process being validated, and the amount of documentation required.We have seen general SOPs, while others use a batch record or log sheet system that requires some type of specific documentation for performing each step. Depending upon the complexity of the system and cleaning process and the ability and training of operators, the amount of documentation necessary for executing various cleaning steps or procedures will vary.When more complex cleaning procedures are required, it is important to document the critical cleaning steps (for example certain bulk drug synthesis processes). In this regard, specific documentation on the equipment itself which includes information about who cleaned it and when is valuable. However, for relatively simple cleaning operations, the mere documentation that the overall cleaning process was performed might be sufficient.Other factors such as history of cleaning, residue levels found after cleaning, and variability of test results may also dictate the amount of documentation required. For example, when variable residue levels are detected following cleaning, particularly for a process that is believed to be acceptable, one must establish the effectiveness of the process and operator performance. Appropriate evaluations must be made and when operator performance is deemed a problem, more extensive documentation (guidance) and training may be required.3. Analytical MethodsDetermine the specificity and sensitivity of the analytical method used to detect residuals or contaminants. With advances in analytical technology, residues from the manufacturing and cleaning processes can be detected at very low levels. If levels of contamination or residual are not detected, it does not mean that there is no residual contaminant present after cleaning. It only means that levels of contaminant greater than the sensitivity or detection limit of the analytical method are not present in the sample. The firm should challenge the analytical method in combination with the sampling method(s) used to show that contaminants can be recovered from the equipment surface and at what level, i.e. 50% recovery, 90%, etc. This is necessary before any conclusions can be made based on the sample results. A negative test may also be the result of poor sampling technique (see below).4. SamplingThere are two general types of sampling that have been found acceptable. The most desirable is the direct method of sampling the surface of the equipment. Another method is the use of rinse solutions.a. Direct Surface Sampling - Determine the type of sampling material used and its impact on the test data since the sampling material may interfere with the test. For example, the adhesive used in swabs has been found to interfere with the analysis of samples. Therefore, early in the validation program, it is important to assure that the sampling medium and solvent (used for extraction from the medium) are satisfactory and can be readily used.Advantages of direct sampling are that areas hardest to clean and which are reasonably accessible can be evaluated, leading to establishing a level of contamination or residue per given surface area. Additionally, residues that are "dried out" or are insoluble can be sampled by physical removal.b. Rinse Samples - Two advantages of using rinse samples are that a larger surface area may be sampled, and inaccessible systems or ones that cannot be routinely disassembled can be sampled and evaluated.A disadvantage of rinse samples is that the residue or contaminant may not be soluble or may be physically occluded in the equipment. An analogy that can be used is the "dirty pot." In the evaluation of cleaning of a dirty pot, particularly with dried out residue, one does not look at the rinse water to see that it is clean; one looks at the pot.Check to see that a direct measurement of the residue or contaminant has been made for the rinse water when it is used to validate the cleaning process. For example, it is not acceptable to simply test rinse water for water quality (does it meet the compendia tests) rather than test it for potential contaminates.c. Routine Production In-Process ControlMonitoring - Indirect testing, such as conductivity testing, may be of some value for routine monitoring once a cleaning process has been validated. This would be particularly true for the bulk drug substance manufacturer where reactors and centrifuges and piping between such large equipment can be sampled only using rinse solution samples. Any indirect test method must have been shown to correlate with the condition of the equipment. During validation, the firm should document that testing the uncleaned equipment gives a not acceptable result for the indirect test.V. ESTABLISHMENT OF LIMITSFDA does not intend to set acceptance specifications or methods for determining whether a cleaning process is validated. It is impractical for FDA to do so due to the wide variation in equipment and products used throughout the bulk and finished dosage form industries. The firm's rationale for the residue limits established should be logical based on the manufacturer's knowledge of the materials involved and be practical, achievable, and verifiable. It is important to define the sensitivity of the analytical methods in order to set reasonable limits. Some limits that have been mentioned by industry representatives in the literature or in presentations include analytical detection levels such as 10 PPM, biological activity levels such as 1/1000 of the normal therapeutic dose, and organoleptic levels such as no visible residue.Check the manner in which limits are established. Unlike finished pharmaceuticals where the chemical identity of residuals are known (i.e., from actives, inactives, detergents) bulk processes may have partialreactants and unwanted by-products which may never have been chemically identified. In establishing residual limits, it may not be adequate to focus only on the principal reactant since other chemical variations may be more difficult to remove. There are circumstances where TLC screening, in addition to chemical analyses, may be needed. In a bulk process, particularly for very potent chemicals such as some steroids, the issue of by-products needs to be considered if equipment is not dedicated. The objective of the inspection is to ensure that the basis for any limits is scientifically justifiable.VI. OTHER ISSUESa. Placebo ProductIn order to evaluate and validate cleaning processes some manufacturers have processed a placebo batch in the equipment under essentially the same operating parameters used for processing product. A sample of the placebo batch is then tested for residual contamination. However, we have documented several significant issues that need to be addressed when using placebo product to validate cleaning processes.One cannot assure that the contaminate will be uniformly distributed throughout the system. For example, if the discharge valve or chute of a blender are contaminated, the contaminant would probably not be uniformly dispersed in the placebo; it would most likely be concentrated in the initial discharge portion of the batch. Additionally, if the contaminant or residue is of a larger particle size, it may not be uniformly dispersed in the placebo.Some firms have made the assumption that a residual contaminant would be worn off the equipment surface uniformly; this is also an invalid conclusion. Finally, the analytical power may be greatly reduced by dilution of the contaminate. Because of such problems, rinse and/or swab samples should be used in conjunction with the placebo method.b. DetergentIf a detergent or soap is used for cleaning, determine and consider the difficulty that may arise when attempting to test for residues. A common problem associated with detergent use is its composition. Many detergent suppliers will not provide specific composition, which makes it difficult for the user to evaluate residues. As with product residues, it is important and it is expected that the manufacturer evaluate the efficiency of the cleaning process for the removal of residues. However, unlike product residues, it is expected that no (or for ultra sensitiveanalytical test methods - very low) detergent levels remain after cleaning. Detergents are not part of the manufacturing process and are only added to facilitate cleaning during the cleaning process. Thus, they should be easily removable. Otherwise, a different detergent should be selected.c. Test Until CleanExamine and evaluate the level of testing and the retest results since testing until clean is a concept utilized by some manufacturers. They test, resample, and retest equipment or systems until an "acceptable" residue level is attained. For the system or equipment with a validated cleaning process, this practice of resampling should not be utilized and is acceptable only in rare cases. Constant retesting and resampling can show that the cleaning process is not validated since these retests actually document the presence of unacceptable residue and contaminants from an ineffective cleaning process.。
FDA清洗验证检查I. 引言自FDA 各种文件(包括化学原料药检查指南、生物技术检查指南)首次提出这个问题之后,清洗过程的验证已经引发了很多讨论。
FDA 的文件明确指出要求对清洗过程进行验证。
本指南讨论了各种可接受(或不可接受)的验证方法,从而使FDA 的检查具有一致性。
但必须清楚地认识到,与其他工艺验证一样,清洗验证方法也不止一种。
所有过程验证的检查标准是检查其科学数据能否证明系统稳定地达到预期目的,系统结果稳定地符合预先制定的标准。
本指南仅适用于设备化学残留物的清洗验证。
II. 背景对于FDA 而言,使用设备前进行清洗不是什么新要求。
1963 年GMP 法(13 3.4)规定"设备应处于清洁、有序的状态"。
1978 年的cGMP 中规定了设备清洗的章节( 21 1. 67)。
要求清洗设备的主要目的还是防止污染或混料。
由于设备清洗维护不当或防尘管理不当,FDA 检查官曾十分注意检查卫生状况。
过去FDA 总是更注意检查青霉素类与非青霉素类药物之间的交叉污染、药品与甾类物质或激素之间的交叉污染问题。
在过去二十年间,因实际或潜在的青霉素交叉污染问题已从市场上撤回了大量的药品。
另一个事件使FDA 对交叉污染问题日益重视,即1988 年从市场上撤回了消胆胺成品制剂,原因是规程不当。
生产该制剂的原料药受到了农业杀虫剂生产中少量中间体和降解物质的污染。
造成交叉污染的主要原因使用了回收溶媒。
而回收溶媒受到了污染,原因是对溶媒桶的重复使用缺少监控。
贮存杀虫剂产生的回溶媒桶又重复地用于贮存该药品生产中的回收溶媒。
而工厂没有对这些溶媒桶进行有效的监控,没有对其中的溶媒进行有效的检验,也没有对桶的清洗规程进行验证。
被杀虫剂污染的部份化学原料药运到了另一地点的第二家工厂生产制剂,使该工厂的流化床干燥器中物料袋受到了杀虫剂的污染,料造成各批产品受到污染,而该工厂根本就没有生产杀虫剂。
1992 年,FDA 对一家海外原料药生产厂发出了进口警告,该工厂使用同一设备生产强力甾类物质和非甾类物质。
FDA清洁验证检查指南(中英文对照)清洗过程验证检查指南GUIDE TOINSPECTIONS VALIDATION OF CLEANINGPROCESSES请注意:本指南是检查官和其他FDA人员的参考材料。
本指南不受FDA约束,并没有赋予任何人任何权利、特权、收益或豁免权。
I.介绍I. INTRODUCTION自从机构文件,包括原料药化学制剂检查指南和生物制剂检查指南,大体上提到该清洗问题以来,就出现了关于清洗过程验证的大量讨论。
这些机构文件清晰的建立了要验证的清洗过程需要达到的要求。
本指南是为了通过讨论实际操作是可接受的(或不可接受的),来建立检查要求的一致性和统一性。
同时,对清洗验证需要了解的是,像其他过程验证一样,可能有不止一种方法来对过程进行验证。
最后,任何验证过程的测试就是指科学数据是否显示出系统与要求相符和产生的结果是否符合预先定义的参数指标。
本指南只适用于化学残留物的设备清洗。
II.背景对于FDA来说,要求设备在使用前进行清洗并不新奇。
1963GMP 法规(部分133.4)中指出“设备***应该按照清洁和有序的方式进行维护***。
”在1978 CGMP法规中也包含了非常相似的有关设备清洗的章节(211.67)。
当然,清洁设备的主要理由是防止药品被污染或掺假。
在历史上,FDA检查官寻找由于对设备不当的清洗和维护和/或不良的灰尘控制系统而带来的总体不卫生情况。
而且,从历史上来说,FDA对非青霉素药品中的青霉素污染或药品中的活性激素或荷尔蒙交叉污染更加关注。
有很多药品在过去十年中被撤回就是因为实际的或潜在的青霉素的交叉污染。
导致FDA对由于不满足要求的过程导致交叉污染的可能性的进一步关注的案例是,1988年对成品药消胆胺树脂USP的撤回。
用于生产成品的原料药被生产农用杀虫剂中产生的中间体和降解物污染。
本案例中的交叉污染被认为是由于回收溶剂的重新使用。
回收溶剂由于缺乏对溶剂桶的重新使用的控制而被污染。
Validation of Cleaning Processes(7/93)SHARETWEETLINKEDINPIN ITMORE SHARING OPTIONSLINKEDINPIN ITEMAILPRINTGUIDE TO INSPECTIONS VALIDATION OF CLEANINGPROCESSESNote: This document is reference material for investigators and other FDApersonnel. The document does not bind FDA, and does no confer any rights, privileges, benefits, or immunities for or on any person(s).I. INTRODUCTIONValidation of cleaning procedures has generated considerable discussionsince agency documents, including the Inspection Guide for BulkPharmaceutical Chemicals and the Biotechnology Inspection Guide, havebriefly addressed this issue. These Agency documents clearly establish the expectation that cleaning procedures (processes) be validated.This guide is designed to establish inspection consistency and uniformity by discussing practices that have been found acceptable (or unacceptable).Simultaneously, one must recognize that for cleaning validation, as withvalidation of other processes, there may be more than one way to validate a process. In the end, the test of any validation process is whether scientificdata shows that the system consistently does as expected and produces a result that consistently meets predetermined specifications.This guide is intended to cover equipment cleaning for chemical residuesonly.II. BACKGROUNDFor FDA to require that equipment be clean prior to use is nothing new, the 1963 GMP Regulations (Part 133.4) stated as follows "Equipment *** shallbe maintained in a clean and orderly manner ***." A very similar section on equipment cleaning (211.67) was included in the 1978 CGMP regulations. Of course, the main rationale for requiring clean equipment is to preventcontamination or adulteration of drug products. Historically, FDAinvestigators have looked for gross insanitation due to inadequate cleaning and maintenance of equipme nt an d/or poor dust con trol systems. Also,historically speak ing, FDA was more concerned about the con tam in ati onof nonpenicillin drug products with penicillins or the cross-contamination ofdrug products with pote nt steroids or horm on es. A nu mber of productshave bee n recalled over the past decade due to actual or pote ntial peni cilli n cross-c on tam in ati on.One eve nt which in creased FDA aware ness of the pote ntial for cross con tam in ati on due to in adequate procedures was the 1988 recall of afinished drug product, Cholestyramine Resin USP. The bulk pharmaceutical chemical used to produce the product had become con tam in ated with low levels of in termediates and degrada nts from the producti on of agricultural pesticides. The cross-c on tam in ati on in that case is believed to have bee n due to the reuse of recovered solve nts. The recovered solve nts had bee n con tam in ated because of a lack of con trol over the reuse of solve ntdrums. Drums that had bee n used to store recovered solve nts from apesticide producti on process were later used to store recovered solve ntsused for the res in manu facturi ng process. The firm did not have adequate con trols over these solve nt drums, did not do adequate testi ng ofdrummed solve nts, and did not have validated clea ning procedures for the drums.Some shipme nts of this pesticide con tam in ated bulk pharmaceutical were supplied to a second facility at a different location for finishing. This resulted in the contamination of the bags used in that facility's fluid bed dryers withpesticide contamination. This in turn led to cross contamination of lotsproduced at that site, a site where no pesticides were no rmally produced.FDA instituted an import alert in 1992 on a foreign bulk pharmaceuticalmanu facturer which manu factured pote nt steroid products as well as non-steroidal products using com mon equipme nt. This firm was a multi-usebulk pharmaceutical facility. FDA con sidered the pote ntial for cross-contamination to be significant and to pose a serious health risk to thepublic. The firm had only recently started a cleaning validation program atthe time of the in spect ion and it was con sidered in adequate by FDA. One of the reas ons it was con sidered in adequate was that the firm was onlylook ing for evide nee of the abse nee of the previous compo und. The firm had evidenee, from TLC tests on the rinse water, of the presence ofresidues of react ion byproducts and degrada nts from the previous process. III. GENERAL REQUIREMENTSFDA expects firms to have writte n procedures (SOP's) detaili ng the cleaning processes used for various pieces of equipme nt. If firms have one clea ning process for clea ning betwee n differe nt batches of the same productand use a differe nt process for clea ning betwee n product cha nges, weexpect the written procedures to address these different scenario. Similarly, if firms have one process for rem oving water soluble residues and ano ther process for non-water soluble residues, the writte n procedure shouldaddress both sce narios and make it clear whe n a give n procedure is to be followed. Bulkpharmaceutical firms may decide to dedicate certa in equipme nt for certa in chemical manu facturi ng process steps that produce tarry or gummyresidues that are difficult to remove from the equipment. Fluid bed dryerbags are ano ther example of equipme nt that is difficult to clea n and is ofte n dedicated to a specific product. Any residues from the clea ning processitself (detergents, solvents, etc.) also have to be removed from the equipme nt.FDA expects firms to have writte n gen eral procedures on how clea ningprocesses will be validated.FDA expects the gen eral validati on procedures to address who is resp onsible for perform ing and appro ving the validati on study, the acceptancecriteria, and when revalidation will be required.FDA expects firms to prepare specific writte n validati on protocols in advance for the studies to be performed on each manu facturi ng system or piece of equipme nt which should address such issues as sampli ng procedures,and an alytical methods to be used in clud ing the sen sitivity of thosemethods. FDA expects firms to con duct the validati on studies in accordance with the protocols and to docume nt the results of studies.FDA expects a final validati on report which is approved by man ageme ntand which states whether or not the clea ning process is valid. The datashould support a con clusi on that residues have bee n reduced to an"acceptable level."IV.EVALUATION OF CLEANING VALIDATIONThe first step is to focus on the objective of the validation process, and wehave see n that some compa nies have failed to develop such objectives. It is not unu sual to see manu facturers use exte nsive sampli ng and testi ngprograms follow ing the clea ning process without ever really evaluati ng the effective ness of the steps used to clea n the equipme nt. Several questi ons n eed to be addressed whe n evaluat ing the clea ning process. Forexample, at what point does a piece of equipme nt or system become clean? Does it have to be scrubbed by hand? What is accomplished by handscrubb ing rather tha n just a solve nt wash? How variable are manual cleaning processes from batch to batch and product to product? The an swers to these questions are obviously important to the inspection and evaluation ofthe clea ning process since one must determ ine the overall effective ness of the process. An swers to these questi ons may also ide ntify steps that canbe elimi nated for more effective measures and result in resource sav ingsfor the compa ny.Determ ine the nu mber of clea ning processes for each piece of equipme nt.Ideally, a piece of equipment or system will have one process for cleaning,however this will depe nd on the products being produced and whether theclea nup occurs betwee n batches of the same product (as in a largecampaig n) or betwee n batches of differe nt products. Whe n the clea ningprocess is used only betwee n batches of the same product (or differe nt lotsof the same in termediate in a bulk process) the firm n eed only meet a criteria of, "visibly clea n" for the equipme nt. Such betwee n batch clea ning processes do not require validati on.1. Equipme nt Desig nExam ine the desig n of equipme nt, particularly in those large systems that may employ semi-automatic or fully automatic clean-in-place (CIP) systems since they represe nt sig nifica nt concern. For example, sanitary type pip ing without ball valves should be used. Whe n suchnonsan itary ball valves are used, as is com mon in the bulk drug industry, the clea ning process is more difficult.When such systems are ide ntified, it is importa nt that operatorsperform ing clea ning operatio ns be aware of problems and havespecial trai ning in clea ning these systems and valves. Determ inewhether the clea ning operators have kno wledge of these systems and the level of training and experie nee in clea ning these systems. Alsocheck the writte n and validated clea ning process to determ ine if these systems have been properly identified and validated.In larger systems, such as those employi ng long tran sfer lines or pipi ng, check the flow charts and pip ing diagrams for the ide ntificati on of valves and writte n clea ning procedures. Pip ing and valves should be tagged and easily identifiable by the operator performing the cleaningfunction. Sometimes, in adequately ide ntified valves, both on prints and physically, have led to in correct clea ning practices.Always check for the prese nee of an ofte n critical eleme nt in thedocume ntati on of the clea ning processes; ide ntify ing and con troll ing the len gth of time betwee n the end of process ing and each clea ning step. This is especially importa nt for topicals, suspe nsions, and bulkdrug operations. In such operations, the drying of residues will directly affect the efficie ncy of a clea ning process.Whether or not CIP systems are used for clea ning of process ingequipme nt, microbiological aspects of equipme nt clea ning should be con sidered. This con sists largely of preve ntive measures rather tha n removal of con tam in ati on once it has occurred. There should besome evide nee that rout ine clea ning and storage of equipme nt does not allow microbial proliferation. For example, equipment should bedried before storage, and un der no circumsta nces should stag nantwater be allowed to rema in in equipme nt subseque nt to clea ningoperati ons.Subseque nt to the clea ning process, equipme nt may be subjected to sterilizati on or san itizati on procedures where such equipme nt is used for sterile process ing, or for non sterile process ing where the products may support microbial growth. While such sterilizatio n or san itizati on procedures are bey ond the scope of this guide, it is importa nt to note that con trol of the bioburde n through adequate clea ning and storageof equipme nt is importa nt to en sure that subseque nt sterilizati on orsanitization procedures achieve the necessary assuranee of sterility.This is also particularly important from the standpoint of the control ofpyroge ns in sterile process ing since equipme nt sterilizati on processes may not be adequate to achieve sig nifica nt in activati on or removal of pyroge ns.2. Clea ning Process Writte nProcedure and Docume ntati onExam ine the detail and specificity of the procedure for the (clea ning)process being validated, and the amount of docume ntati on required.We have see n gen eral SOPs, while others use a batch record or logsheet system that requires some type of specific docume ntati on forperform ing each step. Depe nding upon the complexity of the systemand cleaning process and the ability and training of operators, theamount of docume ntati on n ecessary for executi ng various clea ningsteps or procedures will vary.When more complex clea ning procedures are required, it is importa nt to docume nt the critical clea ning steps (for example certa in bulk drug syn thesis processes). I n this regard, specific docume ntati on on theequipme nt itself which in cludes in formati on about who clea ned it and when is valuable. However, for relatively simple cleaning operations, the mere docume ntati on that the overall clea ning process was performed might be sufficie nt.Other factors such as history of clea nin g, residue levels found aftercleaning, and variability of test results may also dictate the amount ofdocume ntati on required. For example, whe n variable residue levelsare detected follow ing clea ning, particularly for a process that isbelieved to be acceptable, one must establish the effective ness of the process and operator performa nee. Appropriate evaluati ons must bemade and whe n operator performa nee is deemed a problem, moreexte nsive docume ntati on (guida nee) and training may be required. 3. Analytical MethodsDetermine the specificity and sensitivity of the analytical method used to detect residuals or con tam inan ts. With adva nces in an alytical tech no logy, residues from the manu facturi ng and clea ning processes can be detected at very low levels. If levels of contamination or residual are not detected, it does not mean that there is no residual con tam inant prese nt after clea nin g. It only means that levels of con tam inant greaterthan the sensitivity or detection limit of the analytical method are notpresent in the sample. The firm should challenge the analytical method in comb in ati on with the sampli ng method(s) used to show that contam inants can be recovered from the equipme nt surface and at whatlevel, i.e. 50% recovery, 90%, etc. This is n ecessary before any conclusi ons can be made based on the sample results. A n egative testmay also be the result of poor sampli ng tech nique (see below).4. Sampli ngThere are two gen eral types of sampli ng that have bee n foundacceptable. The most desirable is the direct method of sampling thesurface of the equipme nt. Ano ther method is the use of rinse soluti ons.a. Direct Surface Sampli ng - Determi ne the type of samplingmaterial used and its impact on the test data since the sampli ngmaterial may in terfere with the test. For example, the adhesiveused in swabs has been found to interfere with the analysis ofsamples. Therefore, early in the validation program, it is importantto assure that the sampli ng medium and solve nt (used for extraction from the medium) are satisfactory and can be readily used.Advantages of direct sampling are that areas hardest to clean andwhich are reas on ably accessible can be evaluated, lead ing toestablish ing a level of con tam in ati on or residue per give nsurface area. Additi on ally, residues that are "dried out" or are insoluble can be sampled by physical removal.b.systems or ones that cannot be routi nely disassembled can besampled and evaluated.A disadva ntage of rinse samples is that the residue or con tam inantmay not be soluble or may be physically occluded in the equipme nt. An an alogy that can be used is the "dirty pot." In the evaluatio n of cleaning of a dirty pot, particularly with dried out residue, one does no t look at the rinse water to see that it is clea n; one looks at the pot.Check to see that a direct measureme nt of the residue or con tam inant has bee n made for the rinse water whe n it is used to validate the cleaning process. For example, it is not acceptable to simply test rinse water for water quality (does it meet the compendia tests) rather than test it for potential contaminates.c. Rout ine Producti on In-Process Con trolMon itori ng - In direct test ing, such as con ductivity testi ng, may be of some value for rout ine mon itori ng once a clea ning process has bee n validated. This would be particularly true for the bulk drug substa neemanu facturer where reactors and cen trifuges and pip ing betwee nsuch large equipme nt can be sampled only using rinse soluti onsamples. Any in direct test method must have bee n show n to correlate with the condition of the equipment. During validation,the firm should docume nt that test ing the un clea ned equipme nt givesa not acceptable result for the in direct test.ESTABLISHMENT OF LIMITSFDA does not intend to set accepta nee specificati ons or methods for determining whether a cleaning process is validated. It is impractical for FDA to do so due to the wide variati on in equipme nt and products used throughout the bulk and fini shed dosage form in dustries. The firm's rati on ale for the residue limitsestablished should be logical based on the manu facturer's kno wledge of the materials invo Ived and be practical, achievable, and verifiable. It is important to define the sensitivity of the an alytical methods in order to set reas on able limits. Some limits that have bee n men tio ned by in dustry represe ntatives in the literature or in presentations include analytical detection levels such as 10 PPM, biological activity levels such as 1/1000 of the normal therapeutic dose, and orga no leptic levels such as no visible residue.Check the manner in which limits are established. Uni ike fini shedpharmaceuticals where the chemical ide ntity of residuals are known (i.e., from actives, in actives, deterge nts) bulk processes may have partial reacta nts and unwan ted by-products which may n ever have bee n chemically identified. In establishing residual limits, it may not be adequate to focus only on the prin cipal reacta nt since other chemical variati ons may be more difficult to remove. There are circumsta nces where TLC scree ning, in additi on to chemical an alyses, may be n eeded. In a bulk process, particularly for very potent chemicals such as some steroids, the issue of by-products n eeds to be con sidered if equipme nt is not dedicated. The objective of the inspection is to ensure that the basis for any limits is scie ntifically justifiable.OTHER ISSUESa. Placebo ProductIn order to evaluate and validate clea ning processes some manu facturers have processed a placebo batch in the equipme nt un der esse ntially the same operat ing parameters used for process ing product. A sample of the placebo batch is then tested for residual contamination. However, we have docume nted several sig nifica nt issues that n eed to be addressed whe n using placebo product to validate clea ning processes.One cannot assure that the con tam in ate will be uniformly distributedthroughout the system. For example, if the discharge valve or chute of a ble nder are con tam in ated, the con tam inant would probably not be uni formly dispersed in the placebo; it would most likely be concen trated in the in itial discharge portion of the batch. Additi on ally, if the con tam inant or residue is of a larger particle size, it may not be uniformly dispersed in the placebo. V. VI.Some firms have made the assumpti on that a residual con tam inant would be worn off the equipme nt surface uniformly; this is also an inv alid con clusi on.Fin ally, the an alytical power may be greatly reduced by diluti on of the contam in ate. Because of such problems, rinse an d/or swab samples should beused in conj un cti on with the placebo method.b. Deterge ntIf a deterge nt or soap is used for clea ning, determ ine and con sider thedifficulty that may arise whe n attempti ng to test for residues. A com monproblem associated with deterge nt use is its compositi on. Many deterge ntsuppliers will not provide specific compositi on, which makes it difficult for theuser to evaluate residues. As with product residues, it is importa nt and it isexpected that the manu facturer evaluate the efficie ncy of the clea ningprocess for the removal of residues. However, un like product residues, it isexpected that no (or for ultra sen sitive an alytical test methods - very low)deterge nt levels remai n after clea ning. Deterge nts are not part of the manufacturi ng process and are only added to facilitate clea ning duri ng the cleaning process. Thus, they should be easily removable. Otherwise, a differe ntdeterge nt should be selected.c. Test Until CleanExamine and evaluate the level of testing and the retest results since testinguntil clean is a concept utilized by some manufacturers. They test, resample,and retest equipme nt or systems un til an "acceptable" residue level isattained. For the system or equipment with a validated clea ning process, thispractice of resampli ng should not be utilized and is acceptable only in rarecases. Constant retesting and resampling can show that the clea ning processis not validated since these retests actually docume nt the prese nee of unacceptable residue and con tam inants from an in effective clea ning process.REFERENCES0. J. Rodehamel, "Cleaning and Maintenance," Pgs 82-87, University of Wisc VII.onsin's Con trol Procedures in Drug Productio n Sem inar, July 17-22, 1966,William Blockstein, Editor, Published by the University of Wisco nsi n,L.O.C.#66-64234.1. J.A. Constanee, "Why Some Dust Control Exhaust Systems Don't Work,"Pharm. Eng., January-February, 24-26 (1983).2. S.W. Harder, "The Validation of Cleaning Procedures," Pharm. Technol. 8 (5),29-34 (1984)3. W.J. Mead, "Maintenance: Its Interrelationship with Drug Quality," Pharm. Eng.7(3), 29-33 (1987).4. J.A. Smith, "A Modified Swabb ing Tech ni que for Validati on of Deterge ntResidues in Clean-in-Place Systems," Pharm. Technol. 16(1), 60-66 (1992).5. Fourman, G.L. and Mullen, M.V., "Determining Cleaning Validation Acceptanee Limits for Pharmaceutical Manu facturi ng Operati on s," Pharm. Tech nol.17(4), 54-60 (1993).6. McCormick, P.Y. and Cullen, L.F., in Pharmaceutical Process Validation, 2ndEd., edited by I.R. Berry and R.A. Nash, 319-349 (1993)。
清洁验证技术及应用技术指南英文回答:Cleaning Validation Techniques and Applications.Introduction.Cleaning validation is a critical aspect of pharmaceutical and biotechnology manufacturing processes as it ensures that equipment and facilities are clean and free of contaminants. This process involves a series of tests and procedures to demonstrate that cleaning methods are effective in removing product residues, cleaning agents, and other contaminants from equipment surfaces.Validation Techniques.Various validation techniques are employed to assess the effectiveness of cleaning processes. These techniques include:Swabbing: Involves collecting samples from surfaces using sterile swabs and analyzing them for the presence of contaminants.Rinsing: Involves flushing surfaces with a solvent or water and analyzing the rinsate for contaminants.Visual inspection: Involves visually examiningsurfaces for visible residues or defects.Analytical methods: Utilizes analytical techniquessuch as chromatography, spectroscopy, or microscopy to quantify and identify contaminants.Applications of Cleaning Validation.Cleaning validation is applied in variouspharmaceutical and biotechnology processes, including:Equipment cleaning: Validation of cleaning methods for manufacturing equipment, such as reactors, filling machines,and bioreactors.Facility cleaning: Validation of cleaning proceduresfor rooms, corridors, and other areas within manufacturing facilities.Process validation: Integration of cleaning validation into process validation to ensure that cleaning processesdo not affect product quality or safety.Regulatory compliance: Meeting regulatory requirements, such as those from the FDA and EMA, which mandate comprehensive cleaning validation programs.Best Practices for Cleaning Validation.To ensure effective cleaning validation, best practices should be followed, including:Developing a validation plan: Outlining the validation approach, including the validation objective, methods, and acceptance criteria.Using validated methods: Employing validated swabbing, rinsing, and analytical techniques to ensure reliable and accurate results.Controlling cleaning parameters: Standardizingcleaning procedures and controlling parameters such as time, temperature, and cleaning agent concentration.Documenting validation results: Maintaining detailed records of validation tests, including the methodology, data, and analysis.Monitoring cleaning effectiveness: Regularlymonitoring cleaning processes to ensure ongoing compliance with established standards.Conclusion.Cleaning validation is a critical quality control measure in pharmaceutical and biotechnology manufacturing.It provides assurance of equipment and facility cleanliness,reducing the risk of contamination and ensuring product quality and patient safety. By implementing effective validation techniques and following best practices, manufacturers can establish and maintain robust cleaning processes that meet regulatory requirements and industry standards.中文回答:清洁验证技术及应用技术指南。
手把手教你做清洁验证首先需要明确一个概念,清洁验证是针对清洁方法的验证,这个概念一定不能搞错,不管谁问,一定要咬紧牙关说,这个就是针对清洁方法的效果确认,然后才有下一步。
因此,我们在验证之前需要有一个清洁方法。
当你撸起袖子,卷起裤管准备大干的时候,如果在验证之前,你就被告知,你只需要搞出一个验证出来,别的什么幺蛾子就不要折腾了,那么恭喜你,你要么努力说服领导,清洁验证不是那么的单纯,对生产也相当的重要,搞不好清洁不到位就会有不良反应增加甚至更严重的后果。
当然了,这么大的世界,你也许会碰到油盐不进的,那么你有两个选择,要么把袖子裤管放下来卷起铺盖准备走人,要么背起锅开始在造假的路上起早贪黑,这过程的艰辛姑且不论,但是查出来的风险可不是你能承受得了的。
在你衡量完这个之后继续我们的讨论。
说到清洁方法,在你手头有现成的成熟的清洁方法的时候就不说了,可以跳过这一步,进行下一步的操作;如果没有成熟的清洁方法,那么恭喜你,你有机会从头开始了。
当然了,清洁方法成熟的也不要高兴的太早,你还需要对现成的清洁方法进行评估。
拿起你的清洁方法规程,对文件进行评估。
这里评估包括很多方面,首先既然作为规程文件,他必须能够指导操作人员进行操作,这就是说不能有模糊的语句或者描述。
打个比方:温度低于多少度(你拿什么测,要不要测,不测有什么影响);配制适宜的某某溶剂(适宜是什么浓度)。
操作规程能够让操作人员完全了解才是一个成熟可行的文件。
之后需要对文件内容进行评估,比如明明这个产品都不能溶解在清洗剂中,还非要拿来操作。
这样类似的问题有很多,可以参照下文中清洁方法的建立进行评估。
清洁方法的建立过程比较艰辛。
首先你需要从各种标准、指南之类的文件中找到你所有共线生产的产品的物理化学性质,比如溶解性之类的信息,因为这个对你选择清洗剂真的很重要。
了解好溶解性之后开始根据所有共线产品的溶解性进行分类。
需要说明一下,清洗的过程可以认为是一个缓慢溶解或者稀释的过程,所以一定要可以溶解。
GUIDE TO INSPECTIONS VALIDATION OF CLEANING PROCESSESNote: This document is reference material for investigators and other FDApersonnel. The document does not bind FDA, and does no confer any rights,privileges, benefits, or immunities for or on any person(s).I. INTRODUCTIONValidation of cleaning procedures has generated considerable discussionsince agency documents, including the Inspection Guide for BulkPharmaceutical Chemicals and the Biotechnology Inspection Guide, havebriefly addressed this issue. These Agency documents clearly establish the expectation that cleaning procedures (processes) be validated.This guide is designed to establish inspection consistency and uniformity by discussing practices that have been found acceptable (or unacceptable).Simultaneously, one must recognize that for cleaning validation, as withvalidation of other processes, there may be more than one way to validate a process. In the end, the test of any validation process is whetherscientific data shows that the system consistently does as expected andproduces a result that consistently meets predetermined specifications.This guide is intended to cover equipment cleaning for chemical residuesonly.II. BACKGROUNDFor FDA to require that equipment be clean prior to use is nothing new, the 1963 GMP Regulations (Part 133.4) stated as follows "Equipment *** shall be maintained in a clean and orderly manner ***." A very similar section onequipment cleaning (211.67) was included in the 1978 CGMP regulations. Ofcourse, the main rationale for requiring clean equipment is to preventcontamination or adulteration of drug products. Historically, FDAinvestigators have looked for gross insanitation due to inadequate cleaning and maintenance of equipment and/or poor dust control systems. Also,historically speaking, FDA was more concerned about the contamination ofnonpenicillin drug products with penicillins or the cross-contamination of drug products with potent steroids or hormones. A number of products havebeen recalled over the past decade due to actual or potential penicillincross-contamination.One event which increased FDA awareness of the potential for crosscontamination due to inadequate procedures was the 1988 recall of a finished drug product, Cholestyramine Resin USP. The bulk pharmaceutical chemicalused to produce the product had become contaminated with low levels ofintermediates and degradants from the production of agricultural pesticides. The cross-contamination in that case is believed to have been due to thereuse of recovered solvents. The recovered solvents had been contaminatedbecause of a lack of control over the reuse of solvent drums. Drums that had been used to store recovered solvents from a pesticide production processwere later used to store recovered solvents used for the resin manufacturing process. The firm did not have adequate controls over these solvent drums, did not do adequate testing of drummed solvents, and did not have validated cleaning procedures for the drums.Some shipments of this pesticide contaminated bulk pharmaceutical weresupplied to a second facility at a different location for finishing. Thisresulted in the contamination of the bags used in that facility's fluid bed dryers with pesticide contamination. This in turn led to cross contamination of lots produced at that site, a site where no pesticides were normallyproduced.FDA instituted an import alert in 1992 on a foreign bulk pharmaceuticalmanufacturer which manufactured potent steroid products as well asnon-steroidal products using common equipment. This firm was a multi-usebulk pharmaceutical facility. FDA considered the potential forcross-contamination to be significant and to pose a serious health risk to the public. The firm had only recently started a cleaning validation program at the time of the inspection and it was considered inadequate by FDA. One of the reasons it was considered inadequate was that the firm was onlylooking for evidence of the absence of the previous compound. The firm had evidence, from TLC tests on the rinse water, of the presence of residues of reaction byproducts and degradants from the previous process.III. GENERAL REQUIREMENTSFDA expects firms to have written procedures (SOP's) detailing the cleaning processes used for various pieces of equipment. If firms have one cleaning process for cleaning between different batches of the same product and use a different process for cleaning between product changes, we expect thewritten procedures to address these different scenario. Similarly, if firms have one process for removing water soluble residues and another process for non-water soluble residues, the written procedure should address bothscenarios and make it clear when a given procedure is to be followed. Bulk pharmaceutical firms may decide to dedicate certain equipment for certainchemical manufacturing process steps that produce tarry or gummy residuesthat are difficult to remove from the equipment. Fluid bed dryer bags areanother example of equipment that is difficult to clean and is oftendedicated to a specific product. Any residues from the cleaning processitself (detergents, solvents, etc.) also have to be removed from theequipment.FDA expects firms to have written general procedures on how cleaningprocesses will be validated.FDA expects the general validation procedures to address who is responsible for performing and approving the validation study, the acceptance criteria, and when revalidation will be required.FDA expects firms to prepare specific written validation protocols inadvance for the studies to be performed on each manufacturing system orpiece of equipment which should address such issues as sampling procedures, and analytical methods to be used including the sensitivity of thosemethods.FDA expects firms to conduct the validation studies in accordance with the protocols and to document the results of studies.FDA expects a final validation report which is approved by management andwhich states whether or not the cleaning process is valid. The data should support a conclusion that residues have been reduced to an "acceptablelevel."IV. EVALUATION OF CLEANING VALIDATIONThe first step is to focus on the objective of the validation process, and we have seen that some companies have failed to develop such objectives. It is not unusual to see manufacturers use extensive sampling and testingprograms following the cleaning process without ever really evaluating the effectiveness of the steps used to clean the equipment. Several questionsneed to be addressed when evaluating the cleaning process. For example, at what point does a piece of equipment or system become clean? Does it have to be scrubbed by hand? What is accomplished by hand scrubbing rather than just a solvent wash? How variable are manual cleaning processes from batch tobatch and product to product? The answers to these questions are obviously important to the inspection and evaluation of the cleaning process since one must determine the overall effectiveness of the process. Answers to thesequestions may also identify steps that can be eliminated for more effective measures and result in resource savings for the company.Determine the number of cleaning processes for each piece of equipment.Ideally, a piece of equipment or system will have one process for cleaning, however this will depend on the products being produced and whether thecleanup occurs between batches of the same product (as in a large campaign) or between batches of different products. When the cleaning process is used only between batches of the same product (or different lots of the sameintermediate in a bulk process) the firm need only meet a criteria of,"visibly clean" for the equipment. Such between batch cleaning processes do not require validation.1. Equipment DesignExamine the design of equipment, particularly in those large systems thatmay employ semi-automatic or fully automatic clean-in-place (CIP) systemssince they represent significant concern. For example, sanitary type piping without ball valves should be used. When such nonsanitary ball valves areused, as is common in the bulk drug industry, the cleaning process is more difficult.When such systems are identified, it is important that operators performing cleaning operations be aware of problems and have special training incleaning these systems and valves. Determine whether the cleaning operators have knowledge of these systems and the level of training and experience in cleaning these systems. Also check the written and validated cleaningprocess to determine if these systems have been properly identified andvalidated.In larger systems, such as those employing long transfer lines or piping,check the flow charts and piping diagrams for the identification of valves and written cleaning procedures. Piping and valves should be tagged andeasily identifiable by the operator performing the cleaning function.Sometimes, inadequately identified valves, both on prints and physically,have led to incorrect cleaning practices.Always check for the presence of an often critical element in thedocumentation of the cleaning processes; identifying and controlling thelength of time between the end of processing and each cleaning step. This is especially important for topicals, suspensions, and bulk drug operations. In such operations, the drying of residues will directly affect the efficiency of a cleaning process.Whether or not CIP systems are used for cleaning of processing equipment,microbiological aspects of equipment cleaning should be considered. Thisconsists largely of preventive measures rather than removal of contamination once it has occurred. There should be some evidence that routine cleaningand storage of equipment does not allow microbial proliferation. Forexample, equipment should be dried before storage, and under nocircumstances should stagnant water be allowed to remain in equipmentsubsequent to cleaning operations.Subsequent to the cleaning process, equipment may be subjected tosterilization or sanitization procedures where such equipment is used forsterile processing, or for nonsterile processing where the products maysupport microbial growth. While such sterilization or sanitizationprocedures are beyond the scope of this guide, it is important to note that control of the bioburden through adequate cleaning and storage of equipment is important to ensure that subsequent sterilization or sanitizationprocedures achieve the necessary assurance of sterility. This is alsoparticularly important from the standpoint of the control of pyrogens insterile processing since equipment sterilization processes may not beadequate to achieve significant inactivation or removal of pyrogens.2. Cleaning Process Written Procedure and DocumentationExamine the detail and specificity of the procedure for the (cleaning)process being validated, and the amount of documentation required. We have seen general SOPs, while others use a batch record or log sheet system that requires some type of specific documentation for performing each step.Depending upon the complexity of the system and cleaning process and theability and training of operators, the amount of documentation necessary for executing various cleaning steps or procedures will vary.When more complex cleaning procedures are required, it is important todocument the critical cleaning steps (for example certain bulk drugsynthesis processes). In this regard, specific documentation on theequipment itself which includes information about who cleaned it and when is valuable. However, for relatively simple cleaning operations, the meredocumentation that the overall cleaning process was performed might besufficient.Other factors such as history of cleaning, residue levels found aftercleaning, and variability of test results may also dictate the amount ofdocumentation required. For example, when variable residue levels aredetected following cleaning, particularly for a process that is believed to be acceptable, one must establish the effectiveness of the process andoperator performance. Appropriate evaluations must be made and when operator performance is deemed a problem, more extensive documentation (guidance) and training may be required.3. Analytical MethodsDetermine the specificity and sensitivity of the analytical method used to detect residuals or contaminants. With advances in analytical technology,residues from the manufacturing and cleaning processes can be detected atvery low levels. If levels of contamination or residual are not detected, it does not mean that there is no residual contaminant present after cleaning. It only means that levels of contaminant greater than the sensitivity ordetection limit of the analytical method are not present in the sample. The firm should challenge the analytical method in combination with the sampling method(s) used to show that contaminants can be recovered from the equipment surface and at what level, i.e. 50% recovery, 90%, etc. This is necessarybefore any conclusions can be made based on the sample results. A negative test may also be the result of poor sampling technique (see below).4. SamplingThere are two general types of sampling that have been found acceptable. The most desirable is the direct method of sampling the surface of theequipment. Another method is the use of rinse solutions.a. Direct Surface Sampling - Determine the type of sampling material usedand its impact on the test data since the sampling material may interferewith the test. For example, the adhesive used in swabs has been found tointerfere with the analysis of samples. Therefore, early in the validation program, it is important to assure that the sampling medium and solvent(used for extraction from the medium) are satisfactory and can be readilyused.Advantages of direct sampling are that areas hardest to clean and which are reasonably accessible can be evaluated, leading to establishing a level of contamination or residue per given surface area. Additionally, residues that are "dried out" or are insoluble can be sampled by physical removal.b. Rinse Samples - Two advantages of using rinse samples are that a larger surface area may be sampled, and inaccessible systems or ones that cannot be routinely disassembled can be sampled and evaluated.A disadvantage of rinse samples is that the residue or contaminant may not be soluble or may be physically occluded in the equipment. An analogy that can be used is the "dirty pot." In the evaluation of cleaning of a dirtypot, particularly with dried out residue, one does not look at the rinsewater to see that it is clean; one looks at the pot.Check to see that a direct measurement of the residue or contaminant hasbeen made for the rinse water when it is used to validate the cleaningprocess. For example, it is not acceptable to simply test rinse water forwater quality (does it meet the compendia tests) rather than test it forpotential contaminates.c. Routine Production In-Process ControlMonitoring - Indirect testing, such as conductivity testing, may be of some value for routine monitoring once a cleaning process has been validated.This would be particularly true for the bulk drug substance manufacturerwhere reactors and centrifuges and piping between such large equipment can be sampled only using rinse solution samples. Any indirect test method must have been shown to correlate with the condition of the equipment. Duringvalidation, the firm should document that testing the uncleaned equipmentgives a not acceptable result for the indirect test.V. ESTABLISHMENT OF LIMITSFDA does not intend to set acceptance specifications or methods fordetermining whether a cleaning process is validated. It is impractical for FDA to do so due to the wide variation in equipment and products usedthroughout the bulk and finished dosage form industries. The firm'srationale for the residue limits established should be logical based on the manufacturer's knowledge of the materials involved and be practical,achievable, and verifiable. It is important to define the sensitivity of the analytical methods in order to set reasonable limits. Some limits that have been mentioned by industry representatives in the literature or inpresentations include analytical detection levels such as 10 PPM, biological activity levels such as 1/1000 of the normal therapeutic dose, andorganoleptic levels such as no visible residue.Check the manner in which limits are established. Unlike finishedpharmaceuticals where the chemical identity of residuals are known (i.e.,from actives, inactives, detergents) bulk processes may have partialreactants and unwanted by-products which may never have been chemicallyidentified. In establishing residual limits, it may not be adequate to focus only on the principal reactant since other chemical variations may be more difficult to remove. There are circumstances where TLC screening, inaddition to chemical analyses, may be needed. In a bulk process,particularly for very potent chemicals such as some steroids, the issue of by-products needs to be considered if equipment is not dedicated. Theobjective of the inspection is to ensure that the basis for any limits isscientifically justifiable.VI. OTHER ISSUESa. Placebo ProductIn order to evaluate and validate cleaning processes some manufacturers have processed a placebo batch in the equipment under essentially the sameoperating parameters used for processing product. A sample of the placebobatch is then tested for residual contamination. However, we have documented several significant issues that need to be addressed when using placeboproduct to validate cleaning processes.One cannot assure that the contaminate will be uniformly distributedthroughout the system. For example, if the discharge valve or chute of ablender are contaminated, the contaminant would probably not be uniformlydispersed in the placebo; it would most likely be concentrated in theinitial discharge portion of the batch. Additionally, if the contaminant or residue is of a larger particle size, it may not be uniformly dispersed in the placebo.Some firms have made the assumption that a residual contaminant would beworn off the equipment surface uniformly; this is also an invalidconclusion. Finally, the analytical power may be greatly reduced by dilution of the contaminate. Because of such problems, rinse and/or swab samplesshould be used in conjunction with the placebo method.b. DetergentIf a detergent or soap is used for cleaning, determine and consider thedifficulty that may arise when attempting to test for residues. A commonproblem associated with detergent use is its composition. Many detergentsuppliers will not provide specific composition, which makes it difficultfor the user to evaluate residues. As with product residues, it is important and it is expected that the manufacturer evaluate the efficiency of thecleaning process for the removal of residues. However, unlike productresidues, it is expected that no (or for ultra sensitive analytical testmethods - very low) detergent levels remain after cleaning. Detergents are not part of the manufacturing process and are only added to facilitatecleaning during the cleaning process. Thus, they should be easily removable. Otherwise, a different detergent should be selected.c. Test Until CleanExamine and evaluate the level of testing and the retest results sincetesting until clean is a concept utilized by some manufacturers. They test, resample, and retest equipment or systems until an "acceptable" residuelevel is attained. For the system or equipment with a validated cleaningprocess, this practice of resampling should not be utilized and isacceptable only in rare cases. Constant retesting and resampling can showthat the cleaning process is not validated since these retests actuallydocument the presence of unacceptable residue and contaminants from anineffective cleaning process.VII. REFERENCES1) J. Rodehamel, "Cleaning and Maintenance," Pgs 82-87, University ofWisconsin's Control Procedures in Drug Production Seminar, July 17-22, 1966, William Blockstein, Editor, Published by the University of Wisconsin,L.O.C.#66-64234.2) J.A. Constance, "Why Some Dust Control Exhaust Systems Don't Work,"Pharm. Eng., January-February, 24-26 (1983).3) S.W. Harder, "The Validation of Cleaning Procedures," Pharm. Technol. 8 (5), 29-34 (1984)4) W.J. Mead, "Maintenance: Its Interrelationship with Drug Quality," Pharm.Eng. 7(3), 29-33 (1987).5) J.A. Smith, "A Modified Swabbing Technique for Validation of Detergent Residues in Clean-in-Place Systems," Pharm. Technol. 16(1), 60-66 (1992).6) Fourman, G.L. and Mullen, M.V., "Determining Cleaning ValidationAcceptance Limits for Pharmaceutical Manufacturing Operations," Pharm.Technol. 17(4), 54-60 (1993).7) McCormick, P.Y. and Cullen, L.F., in Pharmaceutical Process Validation, 2nd Ed., edited by I.R. Berry and R.A. Nash, 319-349 (1993)There are no references from this document.。