Wear yellow. Work safe.• Measure up to fi ve atmospheric hazards concurrently • Fully customizable to suit any application• Rapidly switch from diffusion mode to the optionalintegrated pump in the fi eldmulti-gas detectorsO 3SeriesQuickly switch from diffusion to integral pump optionReplaceable integrated fi lter • window enables user to visually inspect fi lter • provides superior dust and water resistanceSensor for fi fth toxic, PID,or CO 2 hazardsdisplayRaised buttons, easy to use with gloves 95 dB audible alarm (typical)Four bright, wide-angled alarm barscontinuous dataMultiple charging options availableStainless steel alligator clipAA alkaline or hot-swappable rechargeable battery pack options allow for battery installation in the fi eldInternal vibrating alarm forhigh-noise areasIntegral concussion-proof enclosureBased on the run time of a 5-gas instrument in diffusion mode at +68°F/+20°C, other instrument confi gurations or environmental conditions may increase/decrease the battery life of your instrument.Industrial ApplicationsBoth the diffusion and pumpedconfi gurations are compatible with the MicroDock IIautomated bump test and calibration systemSensorsThe GasAlertMicro 5 is available in three models: toxic/electrochemical, PID (for VOCs) or IR (for CO 2). For more information about available sensor confi gurations, please contact BW Technologies by Honeywell.Electrochemical and catalytic bead sensors available for: H 2S CO O 2SO 2 Cl 2 ClO 2 NH 3 PH 3 HC N NO 2 O 3 Combustibles (LEL)Photoionization sensor available for volatile organiccompounds (VOCs) detection.Infrared (IR) gold series sensors available for carbondioxide (CO 2) detection.Note: Due to board and sensor confi guration GasAlertMicro 5 models are not interchangeable (i.e. a PID sensor cannot be used in a IR configured unit).Integral pump and battery chargerBelt holsterCollapsible sampling probeAdditional GasAlertMicro 5 Features:• Integral motorized pump option for remote sampling • Equipped with internal vibrating alarm for high noise areas • Two power options: AA alkaline or rechargeable hot-swappable battery packs • Multi-language support in English, French, German, Spanish and Portuguese Standard features of BW products:• Continuous LCD shows real-time gas concentrations • Water-resistant• Automatic calibration procedure; compatible with BW MicroDock II automatic test and calibration station • Full function self-test of sensor, battery status, circuit integrity and audible/visual alarms on start up • Bright wide-angled visual alarm bars • Built-in concussion-proof boot。
BW GasAlertMicroClip气体检测仪使用说明[字号:大中小] [浏览次数:24]⇒首次使用前先对检测仪充电。
建议每个工作天后对检测仪充电。
⇒首次使用前应对仪器进行校准,此后,应根据使用情况及仪器对有害气体或污染物的暴露情况进行定期的校准。
建议每180天必须校准一次。
⇒如可燃气体传感器曾暴露于任何催化剂污染物/毒剂(如硫化物,硅蒸汽,卤素化合物等),建议应由已知浓度的标气对其进行测试。
通过使其暴露于浓度超过其高限报警点的气体时,确认检测仪能够对气体作出响应,并激活听觉和视觉警报。
如探测仪读数超出规定范围,应对其进行校准。
⇒可燃气体传感器出厂前经由50%LEL浓度的甲烷进行了校准,如需以%LEL方式检测其他可燃气体,可用其他适合的气体进行校准。
⇒注意:如读数超过测量范围,表示目标气体浓度可能达到了爆炸浓度。
⇒应避免使可燃气体传感器暴露于含铅化合物,硅树脂,氯化碳氢化合物。
尽管有些有机蒸汽(如含铅汽油,卤化碳氢化合物)可能会使传感器暂时停止正常工作,但多数情况下,通过校准能够恢复其功能。
⇒检测仪只能在氧气浓度不超过20.9%(v/v)的潜在爆炸气体环境中使用。
⇒检测仪读数突然上升然后下降或读数不稳可能表示一种气体浓度超出量程上限, 可能是有危险的.⇒ GasAlertMicroClip检测仪长时间暴露于某种浓度的可燃气或空气有可能会加重检测仪的负荷,结果可能会严重影响其性能。
如检测仪曾因高浓度可燃气体而发生报警,应重新对其进行校准,或必要时应更换传感器。
⇒在某些环境中,电磁波的干扰可能会导致仪器非正常工作。
• 启动检测仪,按 C• 关闭检测仪,按住 C 直到OFF(关机)标识倒计时完成,LCD关闭。
• 查看TWA,STEL和最大值(MAX),按C两次;清除TWA,STEL和MAX值,待屏幕出现RE SET(复位)时,按 C。
• 使检测仪进入校准操作,按住 C,检测仪先完成OFF倒计时,继续按住C,显示屏暂时关闭,然后出现CAL倒计时。
VOCs, CO 2, LEL, H 2S, CO, O 2, SO 2, PH 3, NH 3, NO 2, HCN, Cl 2, ClO 2, O 3Protect yourselfCompact and lightweight, GasAlertMicro 5 Series instruments areavailable in diffusion or pumped instruments. The portable gas detectors simultaneously monitors and displays up to five potential atmospheric hazards. The GasAlertMicro 5 PID model also identifies PID detectable VOCs, while the GasAlertMicro 5 IR uses an NDIR sensor to monitorCO 2 levels. Adaptable to a variety of applications, GasAlertMicro 5 Series instruments have an extensive selection of user-settable field options. Use the passcode function to prevent unauthorized modifications of the instrument’s settings. Compatible with BW’s MicroDock II automatic test and calibration system, GasAlertMicro 5 Series instruments are unparalleled in their versatility, performance and overall value.Standard Package Contents• D etector complete with specified sensor(s), stainless steel alligator clip and concussion-proof housing• Rechargeable battery pack or alkaline pack with three AA batteries • Cradle charger and wall outlet charging adaptor (with rechargeable battery option)• Sample probe (with motorized pump option)• Screwdriver• Calibration/test adaptor and hose • Manual• Multi-language CD manual General SpecificationsSize 5.7 x 2.9 x 1.5 in. / 14.5 x 7.4 x 3.8 cm Weight 13.1 oz. / 370 gOperating temperature -4 to +122°F / -20 to +50°C14 to +104°F / -10 to +40°C (PID)Typical battery life 20 hours (15 hours PID/IR)**Based on a 5-gas instrument in diffusion mode at 68ºF / 20ºCCertifications and approvalsClass I, Div. 1, Gr. A, B, C, D American Bureau of Shipping (Toxic and PID models)ATEX: X g II 1 G Ga Ex ia IIC T4*X g II 2 G (IR model only)Ex d ia IIC T4*IECEx: Ga Ex ia IIC T4* Ex d ia IIC T4* (IR model only)*Temperature codes may vary as a function of the batteries installed. Please see owner’s manual for a complete listing of compatible batteries and codes.WarrantyFull two year warranty including sensors (one year Cl 2, NH 3, O 3, ClO 2 and PID sensor)5612-15GasAlertMicro 5.....................................................................................50GasAlertMicro 5 PID ..............................................................................52GasAlertMicro 5 IR ................................................................................54GasAlertMicro 5 Series Accessories, Spares & Replacements ............56GasAlertMicro 5 Series Service Parts (60)GasAlertMicro 5 DetectorOrder NumberGasAlertMicro 5 Region CodesNote: Listed above are commonly ordered instrument configurations. To create a custom GasAlertMicro 5 detector, use the configurator table on the next page or contact BW Technologies for a copy of the electronic order number configurator.GasAlertMicro 5Pump versionGasAlertMicro 5Diffusion versionOrder Number ConfiguratorOrder number:For example, the order number for a GasAlertMicro 5 configured for O 2, %LEL, Cl 2, H 2S and CO and equipped with a rechargeable battery pack and cradle charger, motorized sampling pump, yellow housing and North American powerconnectivity would be M5-XWCY-R-P-D-Y-N-00.*Note: Some gases (e.g. SO 2 and NH 3) cannot be combined in the same GasAlertMicro 5 configuration. Please checkwith Customer Service for specific availability.†Note: HCN can only be ordered in the Toxic 1 location when the Duo-Tox (CO/H 2S) sensor is ordered in theToxic 2 location. In all other configurations, HCN must be ordered in the Toxic 2 location.Note: Listed above are commonly ordered instrument configurations. To create a custom GasAlertMicro 5 PID detector, use the configurator table on the next page or contact BW Technologies for a copy of the electronic order number configurator.GasAlertMicro 5 PIDPump versionGasAlertMicro 5 PIDDiffusion versionOrder Number ConfiguratorOrder number:For example, the order number for a GasAlertMicro 5 PID configured for O 2, %LEL, VOCs, H 2S and CO and equipped with a rechargeable battery pack and cradle charger, motorized sampling pump, yellow housing and North Americanpower connectivity would be M5PID-XWQY-R-P-D-Y-N-00.*Note: Some gases cannot be combined in the same GasAlertMicro 5 configuration. Please check with CustomerService for specific availability.GasAlertMicro 5 IR DetectorOrder NumberGasAlertMicro 5 IR Region CodesNote: Listed above are commonly ordered instrument configurations. To create a custom GasAlertMicro 5 IR detector, use the configurator table on the next page or contact BW Technologies for a copy of the electronic order number configurator.Gas LegendGasAlertMicro 5 IRPump versionGasAlertMicro 5 IRDiffusion versionOrder number:For example, the order number for a GasAlertMicro 5 IR configured for O 2, %LEL, CO 2, H 2S and CO and equipped with a rechargeable battery pack and cradle charger, motorized sampling pump, yellow housing and North American powerconnectivity would be M5IR-XWBY-R-P-D-Y-N-00.*Note: Some gases cannot be combined in the same GasAlertMicro 5 configuration. Please check with CustomerService for specific availability.Order Number ConfiguratorDeluxe Confined Space KitM5-CK-DLConcussion-Proof BootGA-BM5-2For GasAlertMicro 5 Seriespumped unitsCarrying HolsterGA-HM5Fits securely on belt Confined Space Kits Order Number Carrying & Protective Accessories Order NumberConcussion-Proof BootGA-BM5-1For GasAlertMicro 5 Seriesdiffusion unitsSampling & Testing Equipment Order NumberNote: For complete list of Sampling & Testing Equipment, see the Sampling Equipment section.ReplacementTest Cap and HoseM5-TC-1Pump ModuleM5-PUMPReplacementDiffusion CoverM5-DC-1Manual Aspirator PumpGA-AS02For remote sampling; complete withprobe, hose and aspirator pumpAuxiliary Pump Filter withHose ConnectorM5-QCONN-K1Auxiliary Pump FilterM5-AF-K2 / M5-AF-K2-100Kit of 5 or 100, for legacyGeneration 1 pump modules onlyAuxiliary Pump FilterM5-AF-K3 / M5-AF-K3-100Kit of 5 or 100, for Generation 2pump modulesPower Accessories Order Number *Note: Battery packs and chargers should be used with the new version GasAlertMicro 5 Series gas detectors (red circuit boards).MicroDock IIOrder Number Cradle ChargerM5-C01Cradle charger for rechargeable battery packs(can charge battery pack with or without detector attached)Vehicle Adaptor 12 V dcGA-V-CHRG4Vehicle adaptor cable for use with cradle charger (M5-C01)Cradle Charger Kit with BatteryM5-C01-BAT08 / M5-C01-BAT08BComplete with charger and rechargeable battery packAlkaline Battery PackM5-BAT0501/M5-BAT0501B M5-BAT0502/M5-BAT0502BRechargeable Battery PackM5-BAT08/M5-BAT08B5062-26-NCL-EN59PID Cleaning KitM5PID-CLN-K1For PID sensorsReplacement Electrode StackM5PID-ES-1For PID sensorsReplacement 10.6 eV PID LampRL-PID10.6For PID sensorsReplacement Sensor Screens Order Number Replacement SensorsOrder Number Note: All sensors come with a 2 year warranty unless marked with an asterisk (*), denoting 1 year warranty.†Advisory: Detectors are equipped on a standard basis with SR-W04 combustible sensors. This sensor includes a heavy duty silicone filter that make it ideal for use in environments that have known sources of silicone or vapors containing silicon. The SR-W04 silicone filter equipped sensor should not be used when monitoring diesel, kerosene, jet fuel or other heavy hydrocarbon vapors with flashpoint temperatures above 38°C (100°F).Replacement IR SensorSR-B04Replacement PID SensorSR-Q07www.CanarySense .ca Shop for Gas products online at:1.800.561.8187605062-26-NCL-EN Note: Please refer to the instrument’s documentation (shipped with the product or available at ) for complete instructions on common service procedures. Improper servicing or maintenance may affect warranty eligibility. Honeywell assumes no liability for damages resulting from improper servicing or maintenance.www.CanarySense.caShop for Gas products online at: 1.800.561.81875062-26-NCL-EN61Note: Please refer to the instrument’s documentation (shipped with the product or available at ) for complete instructions on common service procedures. Improper servicing or maintenance may affect warranty eligibility. Honeywell assumes no liability for damages resulting from improper servicing or maintenance.LegendService PartsOrder Number How to Replace a Sensor1. With detector OFF , use No. 1 Phillips screwdriver to remove2 screws (G) from back enclosure (F) on either side of the belt clip 2. Lift diffusion cover (A) or pump module straight up3. Remove sensor (O-R) by pulling straight up from PCB (E)4. Insert new sensor (O-R) into PCB (E)5. Replace diffusion cover (A) or pump module6. Replace 2 screws (G) in back enclosure (F) andhand-tighten until firmHow to Replace the Sensor Screen1. With detector OFF , use No. 1 Phillips screwdriver to remove2 screws (G) from back enclosure (F) on either side of the belt clip 2. Lift diffusion cover (A) or pump module straight up3. Remove sensor screen (B) by pulling it straight up fromdiffusion cover (A) or pump module4. Insert sensor screen (B) into diffusion cover (A) orpump module5. Replace diffusion cover (A) or pump module6. Replace 2 screws (G) in back enclosure (F) andhand-tighten until firmwww.CanarySense .ca Shop for Gas products online at:1.800.561.8187。
sEmail:***************222332223五合一气体检测仪保障您的安全S 与同类仪器相比更为小巧,重量减轻一半以上S 连体式外壳,既防震又防水S LCD 显示屏可同时持续显示五种气体浓度S 测量 0 - 1000 ppm 的 VOC (挥发性有机化合物) S 连体采样泵可用于远距离采样S 两种供电方式:AA 碱性电池,或者可随地更换的充电电池组S 报警时发出95分贝高音和两段明亮广角警报灯S 内置振动报警器,适用于非常嘈杂环境S 支援多国语言:英文、法文、德文、西班牙语、西班牙文和葡萄牙文S 三种背景光模式可供选择:标准模式-弱光下(自动),报警时(自动),和需要时激活;报警模式-报警下激活,需要时再次激活;秘密模式S 四个警报级别:所有气体的瞬时低限和高限警报;VOC 和有毒气体的 TWA (时间加权平均值)和 STEL (短期曝露极限)警报S 简单的自动校准程序;与 BW MicroDock II 自动测试和校准站兼容S 记录和指令下显示TWA ,STEL 和气体暴露最大值S 用户可选择的现场选项包括:PID/可燃气体修正因数、语言选择、提示音、校准气体浓度、设置 TWA/STEL 计算选项、设置校准到期日、密码保护、锁定警报、“SAFE”显示功能、静默模式以及选择某些气体的 ppm 精度(如将 SO 2 的测量精度设为 0.1 ppm )S 全功能自检包括:传感器、电池和电路的完整性;听觉/视觉报警订购信息GasAlertMicro 5 PID 配有传感器(需指定)、传感器盒盖(用于扩散采样模式)、电池(需指定)、不锈钢鳄鱼夹、校准盖/软管、2 个额外的电极组、说明书(本地语言)和交互式培训光盘。
一旦交付,即可投入使用。
电池/充电器的选择三节AA 碱性电池可充电电池组和桌式/墙式充电器选配用户下载数据记录器包括32MB MMC 卡、软件和一个用于MicroDock II 自动校准测试的红外端口选配采样泵包括检测仪、标准附件、连体式电动泵和泵盖(已装好)、12 英寸/30 厘米长的采样软管以及带有疏水栅(疏水阀)和微粒过滤器的采样探头、5 英尺/1.5 米长的采样管、5 个备用的微粒过滤器和 1 个备用的疏水阀过滤器。
五合一气体检测仪GasAlertMicro 5/PID/IR所属品牌:加拿大BW五合一气体检测仪GasAlertMicro 5/PID/IR产品详细介绍GasAlertMicro 5 最多可同时监控和显示 5 种有害气体。
GasAlertMicro 5 有 3 种模式:有毒/电化、PID(用于VOC)或 IR(用于 CO2).GasAlertMicro 5 适用于各种应用,具有多种选择的现场用户设定选项,提供标准的有毒气体模式、检测 VOC 的PID 模式或 CO2 检测的 IR 模式。
∙使用密码功能,防止未经授权对仪器设置进行修改。
∙GasAlertMicro 5 可兼容BW 的 MicroDock II 自动测试和校准系统,具有无与伦比的多功能性、性能和整体价值。
∙最多可同时测量 5 种有害气体。
∙完全自定义,适合于任何应用。
∙在现场可迅速从扩散模式切换到可选的连体泵。
∙不间断 LCD 显示实时气体浓度。
∙防水∙启动时进行传感器、电池状态、电路完好性和声音/视觉警报的全功能自检∙明亮的广角可视警报光柱。
∙内置式防震外罩。
∙可用于远程采样的内置电动泵。
∙配有内置振动警报,适用于高噪声区。
∙两种供电方式:AA 碱性电池,或者可即时更换的充电电池组。
∙多语言支持,包括英语、法语、德语、西班牙语和葡萄牙语。
系列工业应用仪器型号差异GasAlertMicro 5 规格●大小:5.7 x 2.9 x 1.5 英寸 / 14.5 x 7.4 x 3.8 厘米●重量:13.1 盎司/370 克●温度:-4 至 +122°F / -20 至 +50°C,-14 至 +104°F / -10 至 +40°C (PID) ●警报:- 视觉、振动和声音(95 分贝),- 低、高、STEL、TWA、OL (超限)●测试:在启动时检查传感器的完好性、线路以及电池的状况并发出声/光警报,电池(不间断)●泵:选配●用户选项:提示音、设置 STEL 间隔、设置 TWA 方法、打开/关闭传感器、锁定警报、安全显示模式、秘密模式、调整时钟、密码保护、修正因数库、(LEL、 PID) 、快速泵、设置数据记录器的速率、可燃气体测量(% LEL或甲烷体积百分比)、启动时 O2 自动校准、自动背光、睡眠模式、用户设定校准气浓度、校准到期锁定、日常冲击测试、语言选择 (5)、高精度●等级:EMI/RFI:符合 EMC Directive 89/336/EEC、IP 65/67●认证和认可:Class I, Div. 1, Gr. A, B, C, D 、American Bureau of Shipping - 有毒气体与 PID模式、ATEX: X g II 1 G T4*、Ex ia IIC T4*、X g II 2 G T4* - 仅限 IR 模式Ex d IIC T4* 、IECEx: Ex ia IIC T4* 、Ex d ia IIC T4* - IR 模式●担保保修: 2 年,包括传感器(NH3 和 PID 灯为 1 年)传感器规格挥发性有机气体检测仪GasAlertMicro 5 PID产品详细介绍简要说明:五种气体同时检测:VOC(PID原理)H2S, CO, O2, SO2, PH3, NH3, NO2, HCN, CL2, CLO2, O3,及%LEL,可更换的传感器。
固定式有毒有害智能气体检测仪 产品使用说明书目 录使用之前 (2)简介 (2)主要特点 (3)技术参数 (3)外形图片 (4)操作说明 (5)菜单设置 (5)常见故障及解决办法 (10)更换传感器 (10)注意事项 (11)保修期 (11)技术性能及参数 (11)11.使用之前(注意:请避雨安装!!!)工作电源:12-30VDC红线:电源正极黄线:4-20mA信号正极黑线:电源负极、4-20mA信号负极仪器不需要额外设置,开机即可使用。
开机需等待30秒预热时间,提前跳过可能导致数值有波动。
如果气体检测仪很长时间未使用(1个星期以上),开机后让仪器先运行一段时间(15分钟以上)后,进入设置模式,观察仪器的零点是否稳定为0左右,如果漂移较大,则需要归零点一次(氧气、氮气检测仪为归目标点一次)。
仪器报警时可以按KEY3键取消报警音,但是报警图标 仍在闪烁;再按KEY3键可以恢复报警音。
2. 简介智能气体检测仪,是一款采用世界顶级的嵌入式微控制器技术,最先进的集成电路技术、标准智能化技术及数字模拟混合通讯技术等合一的完全智能化气体检测仪。
智能气体变送器技术先进、操作简单、功能齐全、可靠性高、稳定性高、安装维护方便。
为了满足广大客户对仪器能够方便、准确的操控,采用了三个按键的操作方式,清晰的数字LCD背光液晶屏幕实时显示气体浓度值。
拥有零点校准和恢复出厂默认设置,可设置的两级声光报警功能适宜各种检测环境中及时、准确的报警提示。
仪器测量气体种类齐全,极大的满足了工业现场安全监测对设备高可靠性稳定运行和测量气2体种类多样化的要求,广泛应用于石油、化工、冶金、炼化、燃气输配、生化医药、农业、实验室及水处理等行业。
3. 主要特点●三个按键的操作方式,能快速准确的设定参数和校准数据●用户可自行设置高低声光报警点,现场可选配高分贝声光报警器●4-20mA信号输出、RS485数字信号输出、两组继电器输出等多种信号输出●气体种类多样化可供选择(根据各种传感器具体而定)●采用国际智能化传感器,快速更换传感器和电池,方便维护●清晰数字LCD背光液晶设计,便于黑暗环境中使用●可操控的数据及恢复出厂设置等功能为客户解决了因操作不当带来的麻烦●仪器跟各种远程控制设备兼容:PLC、二次仪表、控制器、控制报警器、DCS等●铝合金外壳,防爆、防腐蚀。
• Wireless elevates safety to the next level• Over 20 intelligent interchangeable sensor options to cover a wide variety of gases• Man Down Alarm with real-time remote wireless notification • Easy to maintain with replaceable sensor, filter, and Li-ion battery • Fully-automatic bump testing and calibration with AutoRAE 22Applications• Agriculture • Chemical• Fire service / HazMat • Food and beverage • Oil and gasToxiRAE ProPersonal Wireless Monitor for Toxic Gases and OxygenThe ToxiRAE Pro is the industry's first wireless personal monitor for toxic gases and oxygen 1. The ToxiRAE Pro can detect a broad range of gases—from carbon monoxide, hydrogen sulfide, and oxygen to ammonia, chlorine, and formaldehyde 2. The ToxiRAE Pro provides safetyprofessionals wireless remote access to real-time instrument readings and alarm status for better visibility and faster incident response. The ToxiRAE Pro’s intelligent interchangeable sensors store calibration data, which allows users to monitor for one gas one day and another gas the next, by simply swapping the sensors in the ToxiRAE Pro 3.• Wireless access to real-time instrument readings and alarm status from any location•Unmistakable five-way local and remotewireless notification of alarm conditions •Intelligent sensors store calibration data, so they can beswapped in the field•Most electrochemical sensors are shared with MultiRAE family instruments• Largest display in its class•Continuous datalogging • Easy to use•Reliable, rugged, and intrinsically safe•Device Management with Honeywell SafetySuiteFEATURES & BENEFITSToxiRAE Pro Comes With:• ToxiRAE Pro monitor with sensor as specified,alligator clip, protective rubber boot, and rechargeable battery installed• Charging and PC communication cradle • PC communication cable•AC adapter (100 to 240 V, 50/60 Hz AC to 12 V DC)•Calibration adapters• Quick Start Guide • CD with documentation• Calibration certificate , quality certificate, and warranty/registration card• Pharmaceutical • Pulp and paper • Steel manufacturing• Water and wastewater industriesOptional Accessories• AutoRAE 2 Automatic Test and Calibration System • Multi-unit charging station for up to five monitorsToxiRAE Pro Specifications1 Wireless units have a functioning RF modem and areready for wireless deployments; non-wireless units cannot be upgraded to wireless. Additional equipment and/orsoftware licenses may be required to enable remote wireless monitoring and alarm transmission.2 Contact Honeywell RAE Systems for availability.3 Honeywell RAE Systems recommends calibrating sensors on installation.4 Contact Honeywell RAE Systems for country-specificwireless approvals and certificates. Specifications are subject to change.Ordering Information•Wireless or non-wireless versions are available •Refer to the Portables Pricing Guide for part numbers for monitors, accessories, maintenance kits, gas, sensors, and replacement partsFor more information/Honeywell Sensing &Safety Technologies830 East Arapaho Road Richardson, TX 75081/gb/en/software/safety/connected-safety/safety-suiteDevice Management with Honeywell SafetySuite。
目录1.产品概述..................................................................................................................... 错误!未定义书签。
2.技术指标.. (2)3.安装说明 (3)3.1 安装结构图 (3)3.2 安装位置 (3)3.3 安装方法 (3)3.3.1墙壁式安装 (4)3.3.2管装式安装 (4)4.标定说明..................................................................................................................... 错误!未定义书签。
5.使用注意事项.. (4)6.常见故障及维修 (5)7.质量保证..................................................................................................................... 错误!未定义书签。
8.责任限定..................................................................................................................... 错误!未定义书签。
备注:............................................................................................................................... 错误!未定义书签。
2. 产品特点● LCD液晶屏幕,可实时显示检测器的浓度、状态;●使用数字信号传输,可靠性高;●可通过计算机实现本地监控及远程监控,检测器运行状态数据可永久储存;●使用485通讯协议,可靠性高;●隔爆式设计适用于危险条件1、2区;●防水、防尘的结构设计;3.技术参数表1 技术指标表4.安装说明4.1安装结构图图1 气体检测仪外形结构4.2 安装位置●气体检测仪与释放源的距离室外不宜大于2 m ,室内不宜大于1 m ;室内7.5米半径内至少安装一个气体检测仪;●气体检测仪安装位置宜在气体释放源的最小频率风向的上风侧;●要根据被测气体与空气的比重来确定安装高度;●要根据泄漏点人员出现的频率和停留时间、生产设备的新旧程度来选择安装数量,以期达到最佳的安装效果;●要防止高温热源的辐射,过高的温度会降低传感器的性能和使用寿命;●气体检测仪与可能的泄漏点要保持适当距离如需更具体说明,请参考:《石油化工企业可燃气体和有毒气体检测报警设计规范SH3063-1999》4.3 安装方法安装形式可以是墙壁固定式或管装式。