W W W .S I MC O -I O N .C O MIonization SolutionsCritical Environment Benchtop BlowerMODEL 5832The Simco-Ion Critical Environment Benchtop Blower Model 5832 provides reliable, fast static charge control for benchtop work areas and small spaces, allowing optimal electrostatics management that minimizes cost and maximizes protection for ESD-sensitive areas. An internal automatic balance correction system ensures ionization continues to reach your target with complete accuracy presenting a significant time and cost savings.The ionizer can operate with an external sensor to maintain precise balance (better than ±1V) by altering ion output and adapting to environmental changes. With the optional remote sensor or Novx feedback/control, the Model 5832 delivers precisely balanced and directed ionized air to your target without taking up valuable room in your environment. A greater concentration of emitter points and internal circuitry suited for high humidity applications makes the Model 5832 the standard choice for environments that need quality ESD protection with solid design.FeaturesBenefits• ±3V or better balance (±1V with the optional external feedback system)• Provides the best corona-based ESD protection for maximizing yields• Cleanliness rated at ISO 14644 Class 4 (Fed. Std. 209e Class 10)• Designed for use in critical environments with a controlled level of contamination• Options for sensor input, FMS connection, alarms, and management control • Increased control with immediate notification of alarms and the prevention of unauthorized adjustment to power or fan speed• Auto-Clean System• Automates emitter point cleaning, reducing maintenance costs and timeSimco-Ion, Technology Group1141 Harbor Bay Parkway, Suite 201 Alameda, CA 94502Tel: +1 (800) 367-2452 (in USA) Tel: +1 (510) 217-0460 *********************±1V Balance PerformanceNovx Option : The Model 5832’s optional external feedback sensor operates with the Novx 7000 Process Monitor and with the Novx 3352 Passive or Novx 3362 Active Closed-loop Ionizer Controllers to detect and automatically correct the balance. With the antenna placed at the target area, feedback is sent to the Model 5832 blower’s internal control system (RJ Connector). This ensures that your target maintains a ±1V or better balance at all times.Remote Antenna Option : The Model 5832 can be ordered and operated with the remote antenna option which allows any of the standard Novx Passive Antenna assemblies to be connected directly to the 5832 (SMA Connector).DIP Switch SettingsSwitch Description1SENSOR: This switch zero’s the front grill and remote sensor inputs to eliminate offsets caused by the circuitry when the remote sensor is used.2EPC Auto/Man: The second dip switch sets the emitter point cleaner to run on a timer (Auto) or only when the external input is manually activated from the IO terminal block input (Man).3, 4Fan Speed Switch: The remaining two dip switches control the fan speed; four speeds are available. The switch settings for each fan speed are listed in the user manual.Adaptable Options• An audible alarm that operates in addition to the visible array of 3 each LED’s on the front of the blower indicate operational failures including a stalled fan or loss of ionization.• The Auto-Clean System, which reduces maintenance periods by sweeping the emitter points when the blower is turned off and on or on a preset time interval or user activated through the FMS.Power Adapter 14-21328100-240 VAC 50/60 Hz 3.9”L x 1.4”H x 2.1”W (99 x 36 x 52 mm) DS-5832_V2 - 9/19 © 2019 Simco-Ion All rights reserved.Ordering Information1. Tested in accordance with ANSI/ESD STM3.1-2015.。
VENF.EX15902 - Flexible Sprinkler Hose with FittingsFlexible Sprinkler Hose with FittingsModelRated Pressure,psig Max Ambient Temp, °F Nom Inlet by Outlet Size, in.Assembly Length,ft (mm)Max No. of 90° Bends Min Bend Radius, in.Equivalent Length of 1 in.Schedule 40Steel Pipe (C = 120), ft Flexibility Type HD-SP-01AS unbraided 1752251x1/2 2.3 (700)2418Limited HD-SP-01A unbraided 1752251x1/2 2.6 (780)2427Limited HD-SP-02AS unbraided 1752251x1/2 3.3 (1000)3444Limited HD-SP-02A unbraided 1752251x1/2 4.0 (1220)3453Limited HD-SP-03A unbraided 1752251x1/2 5.1 (1540)3468Limited HD-SP-04A unbraided 1752251x1/2 6.0 (1830)3473Limited HD-SP-01BS unbraided 1752251x3/4 2.3 (700)2432Limited HD-SP-01B unbraided 1752251x3/4 2.6 (780)2433Limited HD-SP-02BS unbraided 1752251x3/4 3.3 (1000)3448Limited HD-SP-02B unbraided 1752251x3/4 4.0 (1220)3455Limited HD-SP-03B unbraided 1752251x3/4 5.1 (1540)3463Limited HD-SP-04B unbraided 1752251x3/4 6.0 (1830)3476Limited HD-SPN-01AS unbraided 1752251x1/2 2.3 (700)2424Limited HD-SPN-01A unbraided 1752251x1/2 2.6 (780)2430Limited HD-SPN-02AS unbraided 1752251x1/2 3.3 (1000)3446Limited HD-SPN-02A unbraided 1752251x1/2 4.0 (1220)3453Limited HD-SPN-03A unbraided 1752251x1/2 5.1 (1540)3470Limited HD-SPN-04A unbraided 1752251x1/2 6.0 (1830)3484Limited HD-UB-700 unbraided 200225 1 X 1/2 2.3 (700)2432Limited HD-UB-1000 unbraided 200225 1 X 1/2 3.3 (1000)3455Limited HD-UB-1200 unbraided 200225 1 X 1/2 3.9 (1200)3464Limited HD-UB-1500 unbraided2002251 X 1/24.9 (1500)3475LimitedHD FIRE PROTECT PVT LTD D-6/2, Road No. 34Wagle Industrial EstateThane, Maharashtra 400604 IndiaEX15902HD-UB-1800 unbraided200225 1 X 1/2 5.9 (1800)3481Limited HD-UB-700 unbraided200225 1 X 3/4 2.3 (700)2431Limited HD-UB-1000 unbraided200225 1 X 3/4 3.3 (1000)3450Limited HD-UB-1200 unbraided200225 1 X 3/4 3.9 (1200)3457Limited HD-UB-1500 unbraided200225 1 X 3/4 4.9 (1500)3468Limited HD-UB-1800 unbraided200225 1 X 3/4 5.9 (1800)3479LimitedModelRatedPressure,psigMaxAmbientTemp, °FNom Inletby OutletSize, in.AssemblyLength,ft (mm)MaxNo. of90° BendsMin BendRadius, in.EquivalentLength of1 in.Schedule 40Steel Pipe(C = 120), ftFlexibilityTypeHD-N25-700 unbraided2003001x1/2 2.3 (700)2322Limited HD-N25-1000 unbraided2003001x1/2 3.3 (1000)3339Limited HD-N25-1200 unbraided2003001x1/2 3.9 (1200)3356Limited HD-N25-1500 unbraided2003001x1/2 4.9 (1500)3359Limited HD-N25-1800 unbraided2003001x1/2 5.9 (1800)3367Limited HD-B25-700 braided2003001x1/2 2.3 (700)2322Limited HD-B25-1000 braided2003001x1/2 3.3 (1000)3339Limited HD-B25-1200 braided2003001x1/2 3.9 (1200)3356Limited HD-B25-1500 braided2003001x1/2 4.9 (1500)3359Limited HD-B25-1800 braided2003001x1/2 5.9 (1800)3367Limited HD-B25S-700 braided2003001x1/2 2.3(700)2324Limited HD-B25S-1000 braided2003001x1/2 3.3 (1000)3344Limited HD-B25S-1200 braided2003001x1/2 3.9 (1200)3363Limited HD-B25S-1500 braided2003001x1/2 4.9 (1500)3376Limited HD-B25S-1800 braided2003001x1/2 5.9 (1800)3378Limited HD-B28-700 braided2002251x1/2 2.3 (700)2314Limited HD-B28-1000 braided2002251x1/2 3.3 (1000)3327Limited HD-B28-1200 braided2002251x1/2 3.9 (1200)3331Limited HD-B28-1500 braided2002251x1/2 4.9 (1500)3343Limited HD-B28-1800 braided2002251x1/2 5.9 (1800)3349Limited HD-N25-700 unbraided2003001x3/4 2.3 (700)2328Limited HD-N25-1000 unbraided2003001x3/4 3.3 (1000)3354Limited HD-N25-1200 unbraided2003001x3/4 3.9 (1200)3363LimitedHD-N25-1500 unbraided2003001x3/4 4.9 (1500)3374Limited HD-N25-1800 unbraided2003001x3/4 5.9 (1800)3374Limited HD-B25-700 braided2003001x3/4 2.3 (700)2328Limited HD-B25-1000 braided2003001x3/4 3.3 (1000)3354Limited HD-B25-1200 braided2003001x3/4 3.9 (1200)3363Limited HD-B25-1500 braided2003001x3/4 4.9 (1500)3374Limited HD-B25-1800 braided2003001x3/4 5.9 (1800)3374Limited HD-B25S-700 braided2003001x3/4 2.3 (700)2329Limited HD-B25S-1000 braided2003001x3/4 3.3 (1000)3354Limited HD-B25S-1200 braided2003001x3/4 3.9 (1200)3355Limited HD-B25S-1500 braided2003001x3/4 4.9 (1500)3370Limited HD-B25S-1800 braided2003001x3/4 5.9 (1800)3392Limited HD-B28-700 braided2002251x3/4 2.3 (700)2318Limited HD-B28-1000 braided2002251x3/4 3.3 (1000)3335Limited HD-B28-1200 braided2002251x3/4 3.9 (1200)3341Limited HD-B28-1500 braided2002251x3/4 4.9 (1500)3342Limited HD-B28-1800 braided2002251x3/4 5.9 (1800)3343Limited HD-B-6 Braided1752251x1/2 2.0 (610)17.512Limited HD-B-12 Braided1752251x1/2 4.0 (1220)37.529Limited HD-B-15 Braided1752251x1/2 5.0 (1525)37.568Limited HD-B-18 Braided1752251x1/2 5.9 (1800)37.594Limited HD-B-6 Braided1752251x3/4 2.0 (610)17.521Limited HD-B-12 Braided1752251x3/4 4.0 (1220)37.536Limited HD-B-15 Braided1752251x3/4 5.0 (1525)37.573Limited HD-B-18 Braided1752251x3/4 5.9 (1800)37.599LimitedModelRatedPressure,psigMaxAmbientTemp, °FNom Inletby OutletSize, in.AssemblyLength,ft (mm)MaxNo. of90° BendsMin BendRadius, in.EquivalentLength of1 in.Schedule 40Steel Pipe(C = 120), ftFlexibilityTypeHD-28B-700 braided2002251x1/2 2.3 (700)3318Limited HD-28B-1000 braided2002251x1/2 3.3 (1000)5323Limited HD-28B-1200 braided2002251x1/2 3.9 (1200)7329LimitedHD-28B-1500 braided2002251x1/2 4.9 (1500)9339Limited HD-28B-1800 braided2002251x1/2 5.9 (1800)12350Limited HD-28B-700 braided2002251x3/4 2.3 (700)3320Limited HD-28B-1000 braided2002251x3/4 3.3 (1000)5324Limited HD-28B-1200 braided2002251x3/4 3.9 (1200)7331Limited HD-28B-1500 braided2002251x3/4 4.9 (1500)9340Limited HD-28B-1800 braided2002251x3/4 5.9 (1800)12370LimitedThe model HD-N25 series, HD-B25 series, HD-B25S series and HD-B28 series flexible sprinkler hose with fittings are intended to be installed with the RB-BT-UL-1 and RB-F-58T bracket combination in accordance with the manufacturer's installation instructions dated 21th of December, 2018.The model HD-N25 series and HD-B25S series flexible sprinkler hose with fittings are intended to be installed with the SprinkFlex SFO24BKT1 orSFO48BKT1 bracket combinations in accordance with the manufacturer's installation instructions dated 21th of December, 2018.The model HD-N25 series, HD-B25 series, HD-B25S series and HD-B28 series flexible sprinkler hose with fittings are intended to be installed with the RB-BT-UL-2 and RB-F-58T bracket combination in accordance with the manufacturer's installation instructions dated 21th of December, 2018.The Model HD-SP flexible sprinkler hose with fittings are intended to be installed with the B-13 and A-10 bracket combination in accordance with the manufacturer's installation instructions dated March 4, 2009.The Model HD-SPN flexible sprinkler hose with fittings are intended to be installed with the B-7 end bracket and A-4 center bracket combination in accordance with the manufacturer's installation instructions dated September 1, 2009.The unbraided type flexible sprinkler hose with fittings, HD-UB series are intended to be installed with the A-DFM middle and end bracket combination in accordance with the manufacturer's installation instructions or with the B-COT middle and B-EOT end bracket combination in accordance with the manufacturer's installation instructions dated 21th of December, 2018.The braided type flexible sprinkler hose with fittings, HD-B series are intended to be installed with the A-DFM middle and end bracket combination or the B-CON-B middle and B-EL-B end bracket combination in accordance with the manufacturer's installation instructions dated 19th of February, 2019. The braided type flexible sprinkler hose with fittings, HD-28B series are intended to be installed with A-DFM middle bracket and A-DFM end bracket combination in accordance with the manufacturer's installation instructions dated May 2021, or B-COT middle bracket and B-EOT end bracket combination in accordance with the manufacturer's installation instructions dated May 2021.Last Updated on 2021-07-12 The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up Service. Always look for the Mark on the product.UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "© 2022 UL LLC"。
D escriptionT he 3M™ 8710, 8210, 8812 and 8822 Particulate Respirators provide eff ective respiratory protection for use in industries where workers will be exposed to dust particles and/or non-volatile liquid particles.T ested and certifi ed to AS/NZS 1716:2003.•T raditional convex shape, with nose clip and twin strap design.•D urable, collapse resistant inner shell.• R eliable, eff ective protection against fi ne particles.• 3M™ Advanced Electret Filter Material gives eff ective fi ltration •with low breathing resistance for consistent high quality performance. 3M™ Cool Flow™ exhalation valve off ers improved comfort in • h ot humid environments and/or where work is hard and physical*. M aterialsT he following materials are used in the production of the 8710, 8210, 8812 and 8822 Particulate Respirators:S traps • 8812, 8822 – Polyisoprene 8710 and 8210 – Thermoplastic Elastomer S taples • 8812, 8822 – Steel 8710 and 8210 – no staplesN ose Foam • P olyester N ose Clip • 8210 – Aluminium 8710, 8812, 8822 – Steel F ilter •P olyester / Polypropylene V alve* • P olypropylene V alve diaphragm* • P olyisopreneThese products do not contain components made from natural rubber latex.M aximum mass of products:• U nvalved (8710 & 8210) = 8g •V alved (8812 & 8822) =13gS tandardsThese products meet the requirements of Australian New Zealand Standard AS/NZS 1716:2003, Respiratory protective devices. They should be used to protect the wearer from solid and non-volatile liquid particles only.P articulate Filter Respirators are classifi ed by fi ltering effi ciency and maximum total inward leakage performance (P1 & P2), also by inhalation resistance.P 1 fi lters are indended for use against mechanically generatedparticulates such as those generated from sanding, grinding, drilling, sweeping etc.P2 fi lters are intended for use against both mechanically and thermally generated particulates e.g. welding, brazing etc. P2 fi lters may also help reduce breathing in pathogenic biological airborne particulates such as infl uenza virus.A pprovalsT hese respirators have been produced to comply with the requirements of the Australian / New Zealand Standard AS/NZS 1716:2003 under an agreed production certifi cation scheme operated during manufacture in accordance with the SAI Global StandardsMark programme.A pplicationsT hese respirators are suitable for use in concentrations of solid andnon-volatile liquid particles up to the following limits:E S = Exposure Standard Respiratory protection is only eff ective if it is correctly selected, fi tted and worn throughout the time when the wearer is exposed to hazards.3M ™8710, 8210, 8812 and 8822P articulate Respirators* 8812 and 8822 models onlyDatasheetS electionGuidethe most appropriate personal protective equipment (PPE) will depend on the particular situation and should be made only by a competent person knowledgeable of the assessed risks, actual working conditions and limitations of PPE. Details regarding performance and limitations are set out on the product packaging and user information. If in doubt, contact a safety professional or 3M.For respiratory training and advice please contact your local 3M representative.S torage and TransportationT he 3M™ 8710, 8210, 8812 and 8822 Particulate Respirators have a shelf life of 3 years. End of shelf life is marked on the product packaging. Before initial use, always check that the product is within the stated shelf life (use by date). Product should be stored in clean, dry conditions within the temperature range: – 20°C to + 25°C with a maximum relative humidity of <80%. When storing or transporting this product use original packaging provided.D isposalC ontaminated products should be disposed as hazardous waste in accordance with local regulations.Fitting Instructions 8710 and 8210 onlyS ee Figure 1. a nd 1. 2 . Pre-stretch around entire length of each strap bypulling at 3cm intervals between both hands.C up respirator in one hand with nosepiece at fi ngertips, allow 3. headbands to hang freely below hand. H old respirator under chin, with nosepiece up.4. L ocate the upper strap across the crown of the head and the 5. lower strap below the ears. S traps must not be twisted.6. U sing both hands, mould noseclip to the shape of the lower7. part of the nose to ensure a close fi t and good seal. Pinching the noseclip using only one hand may result in less eff ective respirator performance.T he seal of the respirator on the face should be fi t-checked 8. before entering the workplace.F igure 18812 and 8822 onlyS ee Figure 2. C up respirator in one hand with nosepiece at fi ngertips, allow1. headbands to hang freely below hand. H old respirator under chin, with nosepiece up.2. L ocate the upper strap across the crown of the head and the3. lower strap below the ears. S traps must not be twisted.4. U sing both hands, mould noseclip to the shape of the lower5. part of the nose to ensure a close fi t and good seal. Pinching the noseclip using only one hand may result in less eff ective respirator performance.T he seal of the respirator on the face should be fi t-checked 6. before entering the workplace.F igure 2F it CheckC over the front of the respirator with both hands being careful1. not to disturb the fi t of the respirator.(a) UNVALVED respirator - EXHALE sharply;2. (b) VALVED respirator - INHALE sharply.I f air leaks around the nose, re-adjust the noseclip to 3. eliminate leakage. Repeat the above fi t check.I f air leaks at the respirator edges, work the straps back 4. along the sides of the head to eliminate leakage. Repeat the above fi t check.I f you CANNOT achieve a proper fi t DO NOT enter the hazardous area. S ee your supervisor . U sers should be fi t tested in accordance with AS/NZS 1715. F or information regarding fi t testing procedures, please contact 3M.Please recycle.© 3M 2010. All rights reserved.Important Notice3M does not accept liability of any kind, be it direct or consequential (including, but not limited to, loss of profi ts, business and/or goodwill)arising from reliance upon any information herein provided by 3M. The user is responsible for determining the suitability of the products for their intended use. Nothing in this statement will be deemed to exclude or restrict 3M’s liability for death or personal injury arising from its negligence.Occupational Health andEnvironmental Safety Division 3M Australia Pty Ltd950 Pacifi c Highway Pymble NSW 2073Phone: 136 136Fax: 02 9498 9616TechAssist Helpline: 1800 024 464E-mail:******************.au Website: /au/ohsOccupational Health and Environmental Safety Division 3M New Zealand Ltd94 Apollo Drive, Albany,North Shore City, 0632 Tech Helpline: 0800 364 357Customer services: 0800 252 627Fax: 0800 367 253E-mail:*****************.com Website : /safetyE U _M A S T E R _018710 respirator8210 respirator8812 respirator8822respiratorW arnings and Use LimitationsA lways be sure that the complete product is:• - Suitable for the application;- Fitted correctly;- Worn during all periods of exposure;- Replaced when necessary. P roper selection, training, use and appropriate maintenance are • essential in order for the product to help protect the wearer from certain airborne contaminants. F ailure to follow all instructions on the use of these respiratory • protection products and/or failure to properly wear the complete product during all periods of exposure may adversely aff ect the wearer’s health, lead to severe or life threatening illness or permanent disability. F or suitability and proper, use follow local regulations, refer to all • information supplied or contact an occupational hygienist, safety professional or 3M representative on the Tech Assist Helpline 3M Australia 1800 024 464, 3M New Zealand 0800 364 357. B efore use, the wearer must be trained in use of the complete • product in accordance with applicable Health and Safety standards/guidance.T hese products do not contain components made from natural • rubber latex. T hese products do not protect against gases/vapours.• D o not use in atmospheres containing less than 19.5% oxygen. • (3M defi nition. Individual countries may apply their own limits on oxygen defi ciency.Seek advice if in doubt). D o not use for respiratory protection against atmospheric contami-• nants/concentrations which are unknown or immediately danger-ous to life and health (IDLH). D o not use with beards or other facial hair that may inhibit contact between the face and the product thus preventing a good seal. L eave the contaminated area immediately if:• a) Breathing becomes diffi cult.b) Dizziness or other distress occurs. D iscard and replace the respirator if it becomes damaged,• breathing resistance becomes excessive or at the end of the shift. N ever alter, modify or repair this device.• I n case of intended use in explosive atmospheres, contact 3M.• P roductRange。
气源型防电击脉冲交流离子棒AP-AB1216(标准型)使用说明上海安平静电科技有限公司中国上海桂箐路69号27栋3层电话:021-********传真:021-********AP-AB1216气源型防电击交流脉冲离子棒◆ 产 品 概 述AP-AB1216气源型防电击脉冲交流离子棒是安平公司研制生产的消除物体表面静电的棒型除电装置。
AP-AB1216气源型防电击脉冲交流离子棒使用直流高压电源,采用特制合金电极,通过正、负直流高压交替作用于耦合式电极针,即让直流高压源采用交流实施方式通过耦合器件作用于电极针产生电晕放电,将空气分子电离,产生大量正、负极性的空气离子,并通过压缩空气使其输送至带静电物体表面,中和正、负静电电荷,达到高效、可靠消除物体表面静电的目的。
◆ 产 品 特 点1、为棒型、横置式静电消除器。
2、正、负离子输出比可调,可用于离子平衡度的调整。
800mm -++15V 1.6s 1.5s AP-AB1216300mm-+-13V 0.9s 0.8s 100mm-+-20V 0.1s 0.0s200mm -++16V 0.4s 0.3s3、正、负离子输出频率可调,可适用于不同的消电距离,实现较快的消电速度。
调整高压输出频率,改变离子输出状态-3kv -7kv+7kv +3kv -3kv -7kv+7kv +3kv4、高压异常时声光报警。
5、离子输出特性,用遥控器调整。
IB+P IB-T-N 1Bar 24Fan 3567CT+Vpt 1、"R/S":启动/待机2、"IB+":增大占空比,以消除物体表面多余的负电荷;"IB-":减小占空比,以消除物体表面多余的正电荷3、"P":只正高压工作;"N":只负高压工作4、"Bar"+"1":设定离子棒工作频率为1Hz ; "Bar"+"2":设定离子棒工作频率为3Hz ; "Bar"+"3":设定离子棒工作频率为5Hz ; "Bar"+"4":设定离子棒工作频率为10Hz ; "Bar"+"5":设定离子棒工作频率为20Hz ;"Bar"+"6":设定离子棒工作频率为30Hz ; "Bar"+"7":设定离子棒工作频率为50Hz ;5、"C":重置锁定解锁R/S当平板检测仪或被消电物体表面正电压较大时,按调“IB -”;当平板检测仪或被消电物体表面负电压较大时,按调“IB +”,直至将平衡度调节到理想状态。
MODELSNX20AHJ Model SNX20AHJ is an air/hydraulic service jack in which the liftarm is actuated by a mechanism that utilizes a relatively incompressiblefluid, such as oil, as the force transmitting means, actuated by a pneu-matic power source.Please Read Entire Operating Manual Prior to Use!AIR/HYDRAULICJACK20 TONNE20,000 KGSAFE WORKINGLOADINSPECTIONVisual inspection should be made before each use of the service jack, checking for leaking hydraulic fluid and damaged, loose or missing parts. Each jack must be inspected by a manufacturer’s repair facility immediately, if accidentally subjected to an abnormal load or shock. Any jack which appears to be damaged in any way,found to be badly worn, or operates abnormally MUST BE REMOVED FROM SERVICE until necessary repairs are made by a manufacturer’s authorized repair facility. It is recommended that an annual inspection of the jack be made by a manufacturer’s authorized repair facility and that any defective parts, decals or warning labels be replaced with manufacturer’s specified parts.A list of authorized repair facilities is available from the manufacturer.SNX20AHJ SPECIFICATIONSCapacity . . .20 Tonne (20,000 kg.)Min. Saddle Height . . . . .225 mm Max. Saddle Height . . . . .440 mm Stroke . . . . . . . . . . . . . . .121mmOWNER/USER RESPONSIBILITYThe owner and/or user must have a thorough understanding of the manufacturer’s operating instructions and warnings before using this service jack. Personnel involved in the use and operation of equipment shall be careful, competent, trained, and qualified in the safe operation of the equipment and its proper use when servicing motor vehicles and their components. Warning information should be emphasized and understood. If the operator is not fluent in English, the manufacturer’s instructions and warnings shall be read to and discussed with the operator in the operator’s native language by the purchaser/owner, making sure that the operator comprehends its contents.Owner and/or user must study and maintain for future reference the manufacturer’s instructions. Owner and/or user is responsible for keeping all warning labels and instruction manuals legible and intact. Replacement labels and literature are available from the manufacturer.Handle Length . . . . . . . . . . . .1244 mm Wheel Diameter . . . . . . . . . . . .203 mm Dimensions . . .539Lx325Wx1429H mmPage 3WARNING!READ ALL INSTRUCTIONSAND WARNING INFORMATIONBEFORE OPERATION!OPERATING INSTRUCTIONSIMPORTANT:Before attempting to raise a vehicle, check vehicle service manual for recommended lifting surfaces.1. T o raise load: Close release valve tightly (by turning handle knob clockwise). DO NOT OVERTIGHTEN.Position jack under load so that saddle will contact load firmly and load is centered so it cannot slip. Operate the air valve until saddle approaches the load. Once again check to see that saddle is correctly positioned. Raise load to desired height. Place jack stands of appropriate capacity under the vehicle. DO NOT CRA WL UNDER VEHICLE WHILELIFTING VEHICLE OR PLACING OR REMOVING JACK STANDS! Place jack stands at vehicle manufacturer’s recommended lift areas that provide stable support for the raised vehicle.2. T o lower load: Open release valve VERY SLOWLY (by turning handle knobcounterclockwise). When release valve is opened, saddle and load will be lowered. Lower the vehicle slowly so as not to shock load the jack stands. Once repairs are completed, raise vehicle enough to remove jack stands. Lower vehicle very slowly.CAUTION: Keep hands or feet away from the hinge mechanism of the jack.MAINTENANCE INSTRUCTIONSIMPORTANT! Use only a good grade hydraulic jack oil. Avoid mixing types of oil. Do not use brake fluid, alcohol, glycerin, detergent motor oil, or dirty oil. Improper fluid can cause serious internal damage to the jack, rendering it inoperative.To Add Oil: With saddle fully lowered and ram depressed, set jack in an upright position and remove oil filler plug. Fill until oil is level with filler plug hole.To Change Oil: For best performance and longest life, replace the complete oil supply at least once a year. To drain the oil, remove the filler plug. Lay the jack on its side and allow the oil to run out into suitable drain pan. The oil will run slowly because air must enter as oil drains out. Be careful to prevent dirt or foreign matter from entering the system. Replace with proper oil.LUBRICATIONAll moving joints require lubrication often. Remove handle and grease the lower end of handle where the release mechanism rotates in the handle socket.SOLUTIONThe release valve is not closed.✔Turn the valve clockwise tightly.Low on hydraulic fluid.✔✔Refill the jack to the correct level of hydraulic fluid.Pump seals and back-up ring are defective.✔Clean hydraulic fluid passages, replace seals and renew hydraulic fluid.(Must be serviced by qualified service center)The hydraulic system is filled with air. Open ✔✔the release valve, pump handle rapidly (4) full strokes to purge air, close release valve.Return spring is broken or linkages binding.✔Replace spring if broken. Grease pivot shaft, oil all lift arm linkages.Discharge ball is not sealing hydraulic system and oil may be dirty. Manually flush hydraulic ✔system by raising and lowering lift arm by hand. Open the release valve, as required to raise and lower the lift arm. Manually raise and lower lift arm.P R O B L E M J a c k w i l l n o t l i f t l o a d J a c k w i l l n o t h o l d l o a d o rh a n d l e r i s e s J a c k w i l l n o t l i f t t o i t s f u l l h e i g h t J a c k w i l l n o t l o w e r c o m p l e t e l y J a c k w i l l n o t l i f t s m o o t h l y o r j a c k f e e l s s p o n g y。
用户手册User’s GuideRev.A9固件说明:适用于主程序Rev.C1.02及以上的版本AT527系列电池测试仪安柏精密仪器有限公司电话:0512-********©2005-2018 Applent InstrumentsLtd..产品咨询联系电话:0512-63976842 AT527系列用户手册安全须知当你发现有以下不正常情形发生,请立即终止操作并断开电源线。
立刻与安柏科技销售部联系维修。
否则将会引起火灾或对操作者有潜在的触电危险。
●仪器操作异常。
●操作中仪器产生反常噪音、异味、烟或闪光。
●操作过程中,仪器产生高温或电击。
●电源线、电源开关或电源插座损坏。
●杂质或液体流入仪器。
安全信息为避免可能的电击和人身安全,请遵循以下指南进行操作。
免责声明用户在开始使用仪器前请仔细阅读以下安全信息,对于用户由于未遵守下列条款而造成的人身安全和财产损失,安柏科技将不承担任何责任。
仪器接地为防止电击危险,请连接好电源地线。
不可在爆炸性气体环境使用仪器不可在易燃易爆气体、蒸汽或多灰尘的环境下使用仪器。
在此类环境使用任何电子设备,都是对人身安全的冒险。
不可打开仪器外壳非专业维护人员不可打开仪器外壳,以试图维修仪器。
仪器在关机后一段时间内仍存在未释放干净的电荷,这可能对人身造成电击危险。
不要使用已经损坏的仪器如果仪器已经损害,其危险将不可预知。
请断开电源线,不可再使用,也不要试图自行维修。
不要使用工作异常的仪器如果仪器工作不正常,其危险不可预知,请断开电源线,不可再使用,也不要试图自行维修。
不要超出本说明书指定的方式使用仪器超出范围,仪器所提供的保护措施将失效。
产品咨询联系电话:0512-63976843安装和设置向导有限担保和责任范围常州安柏精密仪器有限公司(以下简称Applent )保证您购买的每一台AT527在质量和计量上都是完全合格的。
此项保证不包括保险丝以及因疏忽、误用、污染、意外或非正常状况使用造成的损坏。
PMF570智能配变终端技术及使用说明书(Ver1.00)许昌智能继电器股份有限公司XUCHANG INTELLIGENT RELAY CO.,LTD.PMF570智能配变终端安全注意事项危险和警告本设备只能由专业人士进行安装。
对于因不遵守本说明书的说明而引起的故障,厂家将不承担任何责任。
注意事项提示在拆除此仪器包装后,设定或使用前,请先阅读此说明书的全部内容。
对于说明书中字体为斜体、加重和“注”的内容请额外予以关注。
为确保此保护设备的保护功能得到良好的使用,请用户依照本说明书的所述方式来对保护设备进行安装、设定、使用。
本说明书不包含所有细节或装置的变更,也未能提供所有与安装、运行、维护方面有关的每种可能的偶然情况。
如果想得到更进一步的有关信息或本说明书中没有充分说明的购买者所需的特殊问题时,请与本公司联系。
目录第一章概述 (1)1.1产品概述 (1)1.2执行标准 (1)第二章适用范围 (1)第三章技术参数 (2)第四章安装 (2)第五章功能说明 (3)5.1配变监测功能 (3)5.2开关量采集功能 (3)5.3配电台区设备监测功能 (4)5.4数据记录及远传功能 (4)5.5数据统计功能 (4)5.6就地指示功能 (5)5.7对时功能 (5)5.8安全防护 (5)5.9无线管理与维护功能 (5)第六章终端接口及指示灯定义 (5)6.1终端接口定义 (5)6.2终端重载连接器接口定义 (7)6.3终端指示灯定义 (8)第七章使用注意事项 (11)第八章运输贮存 (12)第九章声明 (12)第一章概述1.1产品概述PMF570系列智能配变终端主要用于监测配电变压器的运行工况,包括电压、电流、功率、频率、电量、谐波、停电事件等运行参数,以及具有无功补偿、配电变压器低压断路器、剩余电流动作保护器的控制等功能。
该产品遵循国家及电力部有关标准,参照国内外同类产品设计思想,具有可靠性高、容量大等特点。
是实现配电网络现代化的重要组成部分,是电力自动化系统中具有较高的实用价植的终端产品。
PUB. DIE-0420-000重要使用說明版權警告:未經授權記錄受版權保護的資料可能會侵犯版權所有者的權益並違反版權法。
為避免發生觸電的危險,請勿讓本產品暴露在水滴或濺水地方。
主電線插頭用作中斷裝置。
一旦發生意外,請立即拔除主電線插頭。
使用小型電源轉接器時,請勿用布包裹或覆蓋轉接器,請勿將轉接器置於密閉的狹小空間。
CA-110E的識別牌位於底部。
2使用地區LEGRIA HF M52符合(截至2012年1月)以下所列地區的無線電信號法規。
地區澳大利亞、奧地利、比利時、保加利亞、賽普勒斯、捷克共和國、丹麥、愛沙尼亞、芬蘭、法國*、德國、希臘、中國香港特別行政區、匈牙利、冰島、愛爾蘭、義大利、拉脫維亞、列支敦斯登、立陶宛、盧森堡、馬爾他、荷蘭、紐西蘭、挪威、波蘭、葡萄牙、羅馬尼亞、俄羅斯、新加坡、斯洛伐克、斯洛維尼亞、西班牙、瑞典、瑞士、英國*法國:禁止戶外使用。
3商標聲明•SD、SDHC及SDXC標誌是SD-3C, LLC 的商標。
•Microsoft和Windows是微軟公司(Microsoft Corporation)在美國和/或其它國家(地區)的商標或註冊商標。
•App Store、iPhone、iTunes、Mac OS及Macintosh是Apple Inc.在美國和其它國家(地區)註冊的商標。
•「x.v.Color」及「x.v.Color」標誌是商標。
•HDMI、HDMI標誌及高清多媒體介面是HDMI Licensing LLC在美國和其它國家(地區)的商標或註冊商標。
•「A VCHD」及「A VCHD」標誌是Panasonic Corporation及SonyCorporation的商標。
•由Dolby Laboratories授權製造。
「Dolby」及雙D符號是Dolby Laboratories的商標。
•YouTube是Google Inc.的商標。
•Facebook是Facebook, Inc.的註冊商標。
ApplicationThe Alfa Laval Unique PMO Mixproof HT valve is designed for continuous flow management and process safety for horizontal tank inlet and outlet applications across the dairy, food, beverage and many other industries.Benefits•Enhanced product safety, cleanability and operatingefficiency•Spillage-free operation with leakage detection and leakage chamber cleaning•Easy maintenance and parts replacement•Low total cost of ownership•Capable of cleaning shadow areas in tank connectionsStandard designThe Alfa Laval Unique PMO Mixproof HT valve is comprised of a series of base components, including valve body, valve plug, actuator, seat lift and two patented Cleaning-in-Place (CIP) nozzles.The double tangential design of the valve body ensures full drainability in any position, when mounted at the bottom of a cone-shaped tank or on the side. The design of the single valve body makes it suitable to weld directly on the tank or to connect it using a tri-clamp. There are three sizes: 2½”, 3”and 4”. The 4” model features a 1.77” opening, which enables the passage of large particles or efficient handling of high viscosity fluids.The valve is self-cleaning, thanks to two patented CIP nozzles. The first nozzle is designed specifically for plug cleaning. This double-acting nozzle projects cleaning media through the tank connection, ensuring complete cleaning of the seat contact surfaces as well as the shadow area of the tank port. The second is a rotating CIP nozzle incorporated into the unit for optimum cleaning of the full-bore leakage chamber. Leakage detection holes enable visual inspection without requiring valve disassembly and provide advance notificationof parts wear. Few straightforward moveable parts contribute to reliable operation and reduced maintenance costs.The valve can also be fitted with the Alfa Laval ThinkTop V50and V70 for sensing and control of the valve.Working principleThe Alfa Laval Unique PMO Mixproof HT valve is a normally closed (NC) valve controlled from a remote location by means of compressed air. The valve has two independent plugs to separate the liquids; the space between the seals forms a leakage chamber at atmospheric pressure during everyworking condition. Leakage rarely occurs but, should it occur,product leaks into the leakage chamber and exits through the bottom outlet for easy detection.When the valve is open, the leakage chamber is closed. The product then flows from one line to the other. The radial design of the valve ensures that virtually no product spillage occurs during valve operation. It is possible to adapt valve cleaning and water hammer protection to the requirements of individual process specifications.CertificatesTECHNICAL DATAMin. product pressure:Full vacuumAir pressure:Max. 116 PSI (800 kPa)1 This equipment is outside the scope of the directive 2014/34/EU and must not carry a separate CE marking according to the directive as the equipment has no own ignition source.Note!In order to use Unique Mixproof valves in ATEX environment, the blue plastic cover at lower plug must be removed for the valve types where the valve is delivered with the cover mounted.PHYSICAL DATAOther steel parts:1.4301 (304)External surface finish:Semi-bright (blasted)Internal surface finish:Bright (polished), Ra < 32 µinch Product wetted seals:EPDM Actuator seals:NBR Guide strips:PTFEFigure 1. Welding endsFigure 2. Clamp endsState of the art – CleanabilityThe Unique PMO Mixproof HT valve also provides a state of the art solution when there is no CIP pressure or flow from the tank side to clean the seat and plug. The valve is self-cleaning, thanks to two patented Cleaning-in-Place (CIP) nozzles. The first nozzle is designed specifically for plug cleaning. This double-acting nozzle projects cleaning solution through the tankconnection, ensuring complete cleaning of the seat contact surfaces as well as the shadow area of the tank port. The second is a rotating CIP nozzle incorporated into the unit for optimum cleaning of the full-bore leakage chamber.The design of the single valve body makes it suitable to weld directly on the tank or to connect it via a Tri-clamp.The 4” and 6” models feature a 1.77” opening, which enables the passage of very large particles or efficient handling of high viscosity fluids.Options: •Male parts or clamp liners in accordance with required standard.•Control and Indication: ThinkTop or ThinkTop Basic.•Side indication for detection of upper seat lift.•Product wetted seals in HNBR, NBR or FPM.CIP validation kit3”1.2685Standard10004”1.7785Long stroke1000Note!Max. pressure in tank means that a higher pressure in tank will open the valve.It is possible to open with 145 PSI (10 bar) (1000 kPa) in pipe line.When closing the valve the pressure can not be higher than "Max. Tank pressure".* Max. tank pressure seat push tank plug.Pressure drop/capacity diagrams12345678080160240320400480.621A = 2.5″B = 3″C = 4″D = 6″Q [gpm]P [psi]Figure 3. To tank0.511.522.533.54080160240280360440520.409A = 2.5″B = 3″C = 4″D = 6″Q [gpm]P [psi]Figure 4. Straight through12345678080160240320400480A = 2.5″B = 3″C = 4″D = 6″Q [gpm]P [psi]Figure 5. From tankUpper Seat-lift [gpm/psi] 2.5 2.5 3.1 Lower Seat-lift (tank seat lift) [gpm/psi]11.511.534.1 Air consumptionUpper Seat-lift * [cubic inches]242438 Lower Seat-lift (tank seat lift) * [cubic inches]8813 Main Movement * [cubic inches]9999216 Cv-value - SpiralCleanExternal CIP in leakage chamber [gpm/psi] 1.52 1.521.52* [n litre] = volume at atmospheric pressureNote!Recommended min. pressure for External CIP in leakage champer 43.5 psi.Formula to estimate CIP flow during seat lift:(for liquids with comparable viscosity and density to water):Q = Kv ·√Δ pQ = CIP - flow (m3/h)Kv = Kv value from the above tableΔ p = CIP pressure (bar)Dimensions (inch)A*34.1335.5945.47 B8.668.6611.81 OD 2.50 3.00 4.00 ID 2.37 2.87 3.84 t0.060.060.08øD7.327.327.32 E 2.79 3.04 3.63 F1 1.50 1.50 2.95 F2 (Tank plug)0.390.390.39 G0.630.63 1.50 H11.0611.4614.33 J9.699.9212.48 K 6.02 6.228.47 L9.929.9214.92 N 5.98 6.698.27 P 3.52 4.01 4.98S7.097.097.09V°0-67°0-60°0-53°X 1.51 1.44 2.07Y3/4" clamp ferrule3/4" clamp ferrule3/4" clamp ferruleZ4"4"6"M/Tri-clamp0.500.500.63Weight (lb)28.6631.3195.02This document and its contents are subject to copyrights and other intellectual property rights owned by Alfa Laval Corporate AB. No part of this document may be copied, re-produced or transmitted in any form or by any means, or for any purpose, without Alfa Laval Corporate AB’s prior express written permission. Information and services provided in this document are made as a benefit and service to the user, and no representations or warranties are made about the accuracy or suitability of this information and these services for any purpose. All rights are reserved.200003996-1-EN-US© Alfa Laval Corporate AB How to contact Alfa LavalUp-to-date Alfa Laval contact details for all countries are always availableon our website at 。
AP-AC5702 气源型离子棒
1、AP-AC5702气源型离子棒的外观:
2、AP-AC5702 气源型离子棒特点:
1) 为棒型、横置式离子消电器。
2) 采用最新除静电专利技术制造,电性能指标优异。
3) 安全性能良好,发射电极不怕短路,使用寿命长。
4) 在高电压、微电流(μA级)状态下工作,发射电极污染度极小,可工作于高级别、洁净度工作区域。
5) 气源型离子棒出气均匀、用气量小、高效、节能。
6) 棒体底部特制条形槽口,用户可用ø6直径螺栓固定使用。
7) 可广泛应用于电子、光电、印刷、塑胶,纺织等行业。
3、AP-AC5702 气源型离子棒性能参数:
4、AP-AC5702 气源型离子棒安装尺寸:
5、AP-AC5702 气源型离子棒消电效果:
6、AP-AC5702 气源型离子棒放置方式:。