hbcl 3302 简单笔记
- 格式:pdf
- 大小:306.65 KB
- 文档页数:4
Alpha Wire | 711 Lidgerwood Avenue, Elizabeth, NJ 07207Tel: 1-800-52 ALPHA (25742), Web: Customer SpecificationPART NO. 3302ConstructionDiameters (In)1) Component 1 2 X 1 CONDa) Conductor 28 (7/36) AWG TC 0.015b) Insulation 0.010" Wall, Nom. PVC 0.035(1) Color Code Alpha Wire Color Code FCond Color Cond Color Cond Color1 BLACK2 WHITE2) Cable Assembly 2 Components Cableda) Twists: 12.0 Twists/foot (min)b) Core Wrap Clear Mylar Tape, 25% Overlap, Min.3) Shield TC BRAID Shield,90% Coverage, Min.4) Jacket 0.012" Wall, Nom.,PVC0.119 (0.126 Max.)a) Color(s) SLATEb) Print ALPHA WIRE-* P/N 3302 CE ROHS* = Factory CodeApplicable Specifications1) Militarya) Component 1MIL-W-16878/Type B 105°C / 600 V RMS2) CE:EU Low Voltage Directive 2006/95/ECEnvironmental1) CE: EU Directive 2011/65/EU(RoHS2), EU Directive 2015/863/EU (RoHS3):This product complies with European Directive 2011/65/EU (RoHS Directive) of the EuropeanParliament and of the Council of 8 June 2011 and the amending Directive 2015/863/EU of 4June 2015 . No Exemptions are required for RoHS Compliance on this item. Consult AlphaWire's web site for RoHS C of C.2) REACH Regulation (EC 1907/2006):This product does not contain Substances of Very High Concern (SVHC) listed on the EuropeanUnion's REACH candidate list in excess of 0.1% mass of the item. For up-to-date information,please see Alpha's REACH SVHC Declaration.3) California Proposition 65:Exempt from warning labels based on the Consent Judgment. Please see Alpha's CA Prop 65 Statement for more information.PropertiesPhysical & Mechanical Properties1) Temperature Range-55 to 105°C2) Bend Radius 10X Cable Diameter3) Pull Tension 5.4 Lbs, MaximumElectrical Properties(For Engineering purposes only)1) Voltage Rating 600 V RMS2) Capacitance 38 pf/ft @1 kHz, Nominal Conductor to Conductor3) Ground Capacitance68 pf/ft @1 kHz, Nominal4) Characteristic Impedance59 Ω5) Inductance0.22 µH/ft, Nominal6) Conductor DCR65 Ω/1000ft @20°C, Nominal7) OA Shield DCR7.5 Ω/1000ft @20°C, NominalOtherPackaging Flange x Traverse x Barrel (inches)a) 1000 FT12 x 4.5 x 3.5 Continuous lengthb) 100 FT 6.5 x 2 x 1.9 Continuous length[Spool dimensions may vary slightly]Alpha Wire | 711 Lidgerwood Avenue, Elizabeth, NJ 07207Tel: 1-800-52 ALPHA (25742)Although Alpha Wire (“Alpha”) makes every reasonable effort to ensure their accuracy at the time of publication, information and specifications described herein are subject to errors or omissions and to changes without notice, and the listing of such information and specifications does not ensure product availability.Alpha provides the information and specifications herein on an “AS IS” basis, with no representations or warranties, whether express, statutory or implied. In no event will Alpha be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary) whatsoever, even if Alpha had been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.ALPHA WIRE - CONFIDENTIAL AND PROPRIETARYNotice to persons receiving this document and/or technical information. This document is confidential and is the exclusive property of ALPHA WIRE, and is merely on loan and subject to recall by ALPHA WIRE at any time. By taking possession of this document, the recipient acknowledges and agrees that this document cannot be used in any manner adverse to the interests of ALPHA WIRE, and that no portion of this document may be copied or otherwise reproduced without the prior written consent of ALPHA WIRE. In the case of conflicting contractual provisions, this notice shall govern the status of this document. ©2013 ALPHA WIRE - all rights reserved.EU/China ROHS CERTIFICATE OF COMPLIANCETo Whom It May Concern:Alpha Wire Part Number: 33023302 , RoHS-Compliant Commencing With 7/1/2005 ProductionNote: all colors and put-upsThis document certifies that the Alpha part number cited above is manufactured in accordance with Directive 2011/65/EU of the European Parliament, better known as the RoHS Directive (commonly known as RoHS 2), with regards to restrictions of the use of certain hazardous substances used in the manufacture of electrical and electronic equipment. This certification extends to amending Directive 2015/863/EU which expanded the list of restricted substances to 10 items (commonly known as RoHS 3) The reader is referred to these Directives for the specific definitions and extents of the Directives. No Exemptions are required for RoHS Compliance on this item. Additionally, Alpha certifies that the listed part number is in compliance with China RoHS “Marking for Control of Pollution by Electronic Information Products” standard SJ/T 11364-2014. Substance Maximum Control ValueLead0.1% by weight (1000 ppm)Mercury0.1% by weight (1000 ppm)Cadmium0.01% by weight (100 ppm)Hexavalent Chromium0.1% by weight (1000 ppm )Polybrominated Biphenyls (PBB)0.1% by weight (1000 ppm)Polybrominated Diphenyl Ethers (PBDE) ,Including Deca-BDE0.1% by weight (1000 ppm)Bis(2-ethylhexyl) phthalate (DEHP)0.1% by weight (1000 ppm)Butyl benzyl phthalate (BBP)0.1% by weight (1000 ppm)Dibutyl phthalate (DBP) 0.1% by weight (1000 ppm)Diisobutyl phthalate (DIBP)0.1% by weight (1000 ppm)The information provided in this document and disclosure is correct to the best of Alpha Wire's knowledge, information and belief at the date of its release. The information provided is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it will become part of. The intent of this document is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product.Authorized Signatory for the Alpha Wire:Dave Watson, Director of Engineering & QA8/28/2019Alpha Wire711 Lidgerwood Ave.Elizabeth, NJ 07207Tel: 1-908-925-8000。
TMS320VC33系列讲座资料第一讲VC33的电源设计这里主要结合实际项目来讲解VC33的最小系统设计,这一讲为电源电路设计,主要分为一下几个部分进行:DSP系统需要的电源种类 DSP系统电源供电的特殊要求:上电次序数字/模拟混合系统电源处理方法电源电路设计及器件选型电源在PCB设计时的一些注意事项1、给TI DSP供电,TI DSP有5类典型电源引脚:CPU核电源引脚,I/O电源引脚PLL电路电源引脚Flash编程电源引脚(仅C2000系列DSP有)模拟电路电源引脚(仅C2000系列DSP有)2、上电次序,CPU内核先于I/O上电,后于I/O掉电(TMS320F281X例外,刚好相反)CPU内核与I/O供电应尽可能同时,二者时间相差不能太长(一般不能>1s,否则会影响器件的寿命或损坏器件)为了保护DSP器件,应在内核电源与I/O电源之间加一肖特基二极管3、数字与模拟部分单独供电最后通过磁珠接在一点即可4、电源电路设计主要的考虑因素用哪种类型的电源器件:转换效率、成本和空间,输入电压,输出电压(输出电压是否可调、输出电压的路数)输出电流:控制/状态:EN控制、PowerGood状态5、电源器件选型,这里列出一些常用的LDO,供大家在设计时选择双路输出输入电压输出电压输出电流辅助功能TPS767D318: 5V 3.3V/1.8V 1A/1A ENTPS767D301: 5V 3.3V/可调 1A/1A EN单路输出TPS76333: 5V 3.3V 150mA ENTPS76801: 5V 可调 1A EN、PGTPS75701: 5V 可调 3A EN、PGTPS75501: 5V 可调 5A EN、PG我在做VC33设计中用到的电源器件是双路输出的TPS767D318。
实际中的连接电路大家可以参照Datasheet。
6、电源在PCB时的注意事项:数字地、模拟地分开,单点连接,强烈推荐采用多层板,为电源和地分别安排专用的层。
第二章化学热力学初步1. 热力学第一定律WU-=Q∆,由于U为状态函数,所以Q和W也是状态函数,对吗?为什么?答:不对。
Q和W只有在能量交换的时候才会有具体的数值,并且随途径不同,共和热的数值都会有变化,所以不是状态函数。
2. 解释下列名词(1) 体系与环境(2) 热(Q)(3) 功(W)(4) 焓(H)和焓变(H∆)(5) 热力学能U(6) 恒容反应热(Q V)和恒压反应热(Q p)答:(1) 热力学中称研究的对象为体系,称体系以外的部分为环境。
(2) 体系在变化过程中吸收的热量为Q。
(3) 体系对环境所做的功。
(4) H=U+PV当泛指一个过程的时候,其热力学函数的改变量为焓变。
(5) 体系内一切能量的总和叫热力学能。
(6) 在恒容过程中完成的化学反应,其热效应称为恒容反应热。
在恒压过程中完成的化学反应,其热效应称为恒压反应热。
3. 什么叫状态函数?它具有何特性?答:藉以确定体系状态的物理量称为体系的状态函数。
它具有加和性。
4. 何谓热效应?测量方法有哪两种?答:化学反应的热效应为当生成物和反应物的温度相同时,化学反应过程中的吸收或放出的热量。
可以选择恒压和恒容两种条件下测量。
5. 什么叫热化学方程式?书写热化学方程式要注意哪几点?答:表示出反应热效应的化学方程式叫做热化学方程式。
书写化学方程式时要注意一下几点:(1)写热化学方式式,要注意反应的温度和压强条件,如果反应是在298K和1.013×105Pa下进行时,习惯上不予注明。
(2)要注明物质的聚集状态和晶形。
(3)方程式中的配平系数只是表示计量数,不表示分子数。
但计量数不同时,同一反应的反应热数值也不同。
6. ①无机化学中常用的反应热有哪几种?反应热的实质是什么?什么类型的化学反应Q V=Q p?等摩尔的NaOH和NH3·H2O溶液分别与过量的HCl溶液中和所放热量是否相等?为什么?②反应2N2(g)+O2(g)=2N2O(g)在298K时,ΔrH mø=164K J·mol-1, 求反应的ΔU?答:①无机化学中常用的反应热有恒压反应热和恒容反应热。
浅析BCH 码的编码方法0 引言数字信号在传输系统中传输时,不免会受到各种因素的干扰,使到达接收端的数字信号中混有噪声,从而引发错误判决。
为了抗击传输过程中的干扰,必然要利用纠错码的差错控制技术。
BCH 码是纠错码中最重要的子类,其具有纠错能力强,构造方便,编码简单,译码也较易实现一系列优点,在实际应用中被工程人员广泛应用。
1 BCH 码BCH 码是1959年由霍昆格姆(Hocquenghem), 1960年由博斯(Bose)和查德胡里(Chandhari)各自提出的纠多个随机错误的循环码,这是迄今为止发现的最好的线性分组码之一,它有严格的代数结构,它的纠错能力很强,特别是在短和中等码长下,其性能接近理论值,并且构造方便编码简单,特别是它具有严格的代数结构,因此它在编码理论中起着重要的作用。
BCH 码是迄今为止研究的最为详尽,分析得最为透彻,取得成果也最多的码类之一。
该码的生成多项式与最小距离d 之间有密切关系,根据d 的要求可以很容易地构造出码,利用该码的代数结构产生了多种译码方法。
BCH 码可以采用查表编码方法,这是一种利用BCH 码作为线性分组码和循环码的性质和结构特点来编写编码表,然后通过查表来编码的一种方法,也可以采用编码器进行编码,还可以应用代数算法,在本文将分别介绍这些算法。
2 BCH 码的k n -级编码器()k n , BCH 码是一类循环码,它的编码方法和传统的循环码完全相同,根据循环码的生成多项式()x g 或校验多项式()x h ,可推出BCH 码的编码电路是一个k n -级或k 级移存器电路,在k>n-k 时,一般采用k n -级编码电路。
用于产生系统码k n -级编码器的原理这样的:将信息多项式()x m 乘以kn x-成为()x m x k n -,然后用()x g 除()x m x k n -得到余式()x r , ()x r 的系数就是校验位,因此这可以根据生成多项式()x g 反馈连接的移位寄存器构成的除法电路完成。
HMR3200/HMR3300型数字罗盘用户手册目录概述 (3)规格性能参数 (3)插脚配置 (4)电路说明 (4)结构参数 (5)应用说明 (6)UART通讯协议 (6)运行命令 (6)设置命令 (7)磁场滤波器 (8)响应命令 (8)数字表示 (9)SPI时间设定 (9)电路板模块演示套件 (10)通讯开发套件 (10)开发套件安装 (10)HMR3200型演示程序的操作 (11)HMR3300型演示程序的操作 (11)简介霍尼韦尔HMR3200/HMR3300型数字罗盘是一种电子式罗盘装置,主要用于航海和导航系统,霍尼韦尔磁阻传感器为这些小型的固态电子罗盘装置提供了足够的可靠性和精确性,这类罗盘装置很容易在系统中集成,只需要使用ASCII格式的UART或者SPI 协议就可以方便地实现。
HMR3200型数字罗盘是双轴式罗盘,既可以用于垂直方向的探测,也可以用于水平方向的探测。
HMR3300型数字罗盘是三轴式罗盘,属于可以倾斜补偿的罗盘,由于使用了双轴式加速度计,性能得到了极大的提高,倾斜角度可以达到±60°。
技术规格参数适用条件最小值标准值最大值单位航向精度水平0°至±30°(仅HMR3300)±30°至±60°(仅HMR3300) 1.03.04.0RMS 度(°)分辨率 0.1 度(°)磁滞性HMR3200HMR3300 0.10.20.20.4度(°)重复性HMR3200HMR3300 0.10.20.20.4度(°)纵倾与侧倾(仅HMR3300)范围纵倾与侧倾范围 ±60° 度(°)精度0至±30°±30°至±60° 0.41.00.51.2度(°)零位精度水平-20°至+70°热磁滞性能-40°至+85°热磁滞性能 0.41.0度(°)分辨率 0.1 度磁滞性 0.2 度重复性 0.2 度磁场范围最大磁通量 ±2 高斯分辨率 0.1 毫高斯电场输入电压未调制 6 15 直流电压电流HMR3200HMR3300 18222024mAmA参数适用条件最小值标准值最大值单位数字接口UART协议 ASCII(1启动、8数字、1停止、无奇偶校验)用户可以选择波特率2400 19200波特SPI CKE=0, CKP=0虚拟主通道更新速率连续/选通/平均HMR3200 HMR3300 158Hz连接器在线8插脚模块(间距0.1”)物理量外形尺寸电路板组件 25.4×36.8×11mm重量HMR3200HMR3300 7.257.5g环境温度工作温度(HMR3200)工作温度(HMR3300)储存温度-40-20-55---+85+70+125°C插脚配置插脚编号插脚名称描述1 SCKSPI 模式串行时钟输出2 RX/SDIUART 接收数据/SPI 数据输入3 TX/SDOUART 发送数据/SPI 数据输出4 CSSPI模式(输入)时选用跟踪侧模块5 CAL开关触发(输入)跟踪侧校正6 +5VDC*备选的+5VDC 电源(输入)7 接地电源和信号接地8 +V*未稳压的电源输入(+6 到+15VDC)*注:电路板可以用插脚6(+5VDC)或插脚8(+V)接口供电,手持模块时将插脚侧靠近自己,并将插脚朝下,则最左边为插脚1。