静音接触器样本
- 格式:pdf
- 大小:978.99 KB
- 文档页数:11
TeSys® F 电动机起动设备产品目录2017关于施耐德电气施耐德电气是全球能效管理和自动化领域的专家,致力于为客户提供安全、可靠、高效、经济以及环保的能源和过程管理。
集团2016财年销售额为247亿欧元,在全球100多个国家拥有16万名员工。
从最简单的开关产品到复杂的运营系统,我们的技术、软件和服务帮助客户管理和优化运营,通过互联互通的科技助力产业优化,改善城市生态,丰富人们的生活。
在施耐德电气,我们称之为:Life Is On施耐德电气中国•中国已经成为集团在全球第二大市场•在中国拥有26000名员工•3个主要研发中心和1个施耐德电气研修学院•26家工厂、8个物流中心、5个分公司和40个办事处遍布全国1/1F 型接触器与可逆接触器● 选型指南 ...........................................................................................................1/2● 特性 ..................................................................................................................1/4● 接触器选型指南○ 用于至450 kW/1000V 的电动机控制,AC-3类别 .............................................1/12○ 用于200A 至2600A 的电路控制,AC-1类别 .....................................................1/13● 根据电气寿命选型○ AC-3使用类别 .................................................................................................1/14○ AC-1使用类别 .................................................................................................1/15○ AC-2或AC-4使用类别 .....................................................................................1/16○ DC-1至DC-5使用类别 .....................................................................................1/18● 用于电动机控制的可逆接触器,AC-3类别○ 至147kW/1000V .............................................................................................1/20● 用于电源转换的接触器组,AC-1类别○ 200A 至350 A ..................................................................................................1/21● 可逆接触器和电源转换接触器组的装配元件 ...................................................1/22● 辅助模块与附件 ..............................................................................................1/27● F 型接触器线圈○ 交流50/60Hz 线圈............................................................................................1/34○ 交流40-400Hz 线圈 .........................................................................................1/35○ 交流40-400Hz 线圈,特殊应用 ........................................................................1/38○ 直流线圈 .........................................................................................................1/40○ 直流线圈,特殊应用 .......................................................................................1/42○ 宽幅电压直流线圈,特殊应用 .........................................................................1/43● 尺寸、安装与线路图 .......................................................................................1/44● 大功率电源转换接触器组,交流或直流○ 概述 ................................................................................................................1/54○ 型号 ................................................................................................................1/55○ 尺寸、线路图 ..................................................................................................1/56● 星-三角起动器,用户自行组装○ 型号 ................................................................................................................1/59○ 尺寸、安装、线路图 .......................................................................................1/62F 型电子式热过载继电器● 概述、说明 .......................................................................................................2/2● 特性 ..................................................................................................................2/3● 型号 ..................................................................................................................2/6● 辅助模块与附件 ................................................................................................2/8● 尺寸、线路图、设置说明 ................................................................................2/10TeSys F目录选型指南TeSys 接触器LC1 F AC3 (115至1800A)LC1 F AC1 (200至2750A)115 A150 A265 A330 A1/21/3特性TeSys 接触器LC1 F AC3 (115至1000A)LC1 F AC1 (200至2600A)控制电路:交流或直流供电(2) 在最恶劣的情况下,不改变触点状态(线圈电压 Uc)。
Freedom Series NEMA Contactors – Overview• Market leader in NEMA power control • Most complete line in the industry• Ideal for project construction, HVAC, pump and industrial applications • Open and enclosed versionsType CN15/CN55 NEMA Contactors – Model SelectionNEMA Size Continuous Ampere Rating Maximum UL Horsepower 3-Pole Non-Reversing 3-Pole Reversing 1-Phase 3-Phase 115V 230V 208V 240V 480V 600V Catalog Number 1Catalog Number 10091/311-1/21-1/222CN15AN3_B CN55AN3_B 018123355CN15BN3_B CN55BN3_B 127237-1/27-1/21010CN15DN3_B CN55DN3_B 24537-1/210152525CN15GN3_B CN55GN3_B 390––25305050CN15KN3_CN55KN3_4135––4050100100CN15NN3_CN55NN3_5270––75100200200CN15SN3_CN55SN3_6540––150200400400CN15TN3_B CN55TN3_B 7810––200300600600CN15UN3_CN55UN3_821215––400450900900CN15VN3_CN55VN3_1 When ordering, replace magnet coil alpha designation in catalog number (_) with proper code suffi x from table below.2Common control. For separate 120V control, insert letter D in seventh position of listed catalog number (ex. CN15VND3C).Magnet Coils (AC and DC) – Model SelectionCoil Volts and Hertz Code Suffi x Coil Volts and Hertz Code Suffi x 120/60, 110/50240/60, 220/50480/60, 440/50600/60, 550/50A B C D 380-415/50550/5024/60, 24/50 424/50L N T U 208/60277/60208-240/60 3240/50E H J K32/5048/6048/50V W Y3 NEMA Sizes 00 and 0 only.4NEMA Sizes 00 and 0 only. Sizes 1 through 8 are 24/60 only.NEMA Contactors forthe Construction MarketNEMA Size 1 ContactorAuxiliary Contacts – Model SelectionSide-Mounted, NEMA Sizes 00 to 2, IEC Sizes A to K Description Contact Confi guration Code 5Catalog Number 1NO 1NC1001C320KGS1C320KGS21NO-1NC 2NO 2NC1NO-1NCI1NO (EC) - 1NC (LO)1NCI112002N/A N/A N/AC320KGS3C320KGS4C320KGS5C320KGS6C320KGS7C320KGS85This two-digit code is found on the auxiliary contact to assist in identifying the specifi c contact confi guration. The fi rst digit indicates the quantity of NO contacts and the second indicates the quantity of NC contacts.Additional Freedom Series auxiliary contacts are available. For a complete listing of theseaccessories, see the Control Products & Services Catalog (CA08102001E), Tab 33.Eaton Corporation Electrical Group1000 Cherrington Parkway Moon Township, PA 15108United States877-ETN-CARE (877-386-2273)© 2009 Eaton Corporation All Rights ReservedPublication No. TD03301007EApril 2009PowerChain Management is a registered trademark of Eaton Corporation. All other trademarks are property of their respective owners.Quick Selector TD03301007EApril 2009NEMA Contactors for the Construction MarketFreedom Series NEMA Starters – Overview• Three-phase, full voltage magnetic starters most commonly used to switch ACmotor loads • Bimetallic ambient compensated overload relays • These overload relays feature:• Interchangeable heater packs adjustable ±24% to match motor FLA • Selectable manual or automatic reset operation• Single-phase protection, Class 20 or Class 10 trip time • Overload trip indication•Electrically isolated NO-NC contacts (pull RESET button to test)• Also available with solid-state overload relays (see T ab 33 of the Control Products & Services Catalog, CA08102001E)Type AN16/An56 NEMA Starters – Model SelectionNEMA Size Continuous Ampere Rating Service-Limit Current Ratings 2Maximum UL Horsepower3-Pole Non-Reversing 3-Pole Reversing Vertical Reversing 1-Phase 3-Phase 115V 230V 208V 240V 480V 600V Catalog Number 1Catalog Number 1Catalog Number 1009111/311-1/21-1/222AN16AN0_C AN56AN0_C –01821123355AN16BN0_C An56BN0_C AN56BNV0_12732237-1/27-1/21010AN16DN0_B AN56DN0_B AN56DNV0_2455237-1/210152525AN16GN0_B AN56GN0_B AN56GNV0_390104––25305050AN16KN0_AN56KN0_AN56KNV0_4135156––4050100100AN16NN0_AN56NN0_AN56NNV0_5270311––75100200200AN16SN0_B AN56SN0_B –6540621––150200400400AN16TN0_C AN56TN0_B –7810932––200300600600AN16UN0_B AN56UN0_B –8312151400––400450900900AN16VN0_BAN56VN0_B–1 When ordering, replace magnet coil alpha designation in catalog number (_) with proper code suffi x from table below.2The service-limit current ratings represent the maximum RMS current, in amperes, which the controller shall be permitted to carry for protracted periods in normal service. At service-limit current ratings, termperature rises shall be permitted to exceed those obtained by testing the controller at its continuous current rating. The current rating of overload relays or trip current of other motor protective devices used shall not exceed the service-limit current rating of the controller.3Common control. For separate 120V control, insert letter D in seventh position of listed catalog number (ex. CN15VND3C).Magnet Coils (AC and DC) – Model SelectionCoil Volts and Hertz Code Suffi x Coil Volts and Hertz Code Suffi x 120/60, 110/50240/60, 220/50480/60, 440/50600/60, 550/50A B C D 380-415/50550/5024/60, 24/50 524/50L N T U 208/60277/60208-240/60 4240/50E H J K32/5048/6048/50V W Y4 NEMA Sizes 00 and 0 only.5NEMA Sizes 00 and 0 only. Sizes 1 through 8 are 24/60 only.Freedom Series Non-Reversing StarterNEMA Size 1Freedom Series Reversing StarterNEMA Size 1Freedom Series Auxiliary ContactsAuxiliary Contacts – Model SelectionSide-Mounted, NEMA Sizes 00 to 2, IEC Sizes A to K Description Contact Confi guration Code 6Catalog Number 1NO 1NC1001C320KGS1C320KGS21NO-1NC 2NO 2NC1NO-1NCI1NO (EC) - 1NC (LO)1NCI112002N/A N/A N/AC320KGS3C320KGS4C320KGS5C320KGS6C320KGS7C320KGS86This two-digit code is found on the auxiliary contact to assist in identifying the specifi c contact confi guration. The fi rst digit indicates the quantity of NO contacts and the second indicates the quantity of NC contacts.Additional Freedom Series auxiliary contacts are available inNEMA sizes 3 to 8 and IEC sizes L to Z. For a complete listing of these accessories, see the Control Products & Services Catalog (CA08102001E), Tab 33.。
静音交流接触器 在电梯行业内的应用一.电梯行业发展现状及对接触器的需求要点■要求接触器噪音小,满足无机房电梯的使用▲现在楼宇建设为了减少公摊面积,尽量缩小客用电梯机房体积,电梯企业为此把制造无机房电梯作为发展趋势。
无机房电梯容易产生噪音,噪音来源主要是接触器的动作声音和电流噪音,为此接触器噪音小才能满足无机房电梯的要求。
电梯为接触器通常提供交流电源,目前减小接触器噪音的通行方式:一是接触器采用直流操作线圈通过整流满足电梯电源,以此来消除接触器工作时的电流噪音;二是减少接触器的动作噪音。
■要求接触器具有封星功能▲随着稀土永磁材料的性能不断完善,永磁同步电机技术的发展,永磁同步无齿轮曳引电机在电梯上得到了广泛的应用。
永磁同步电机具有短路发电机特性,这一特性被广泛应用于电梯,主要起电梯停止时防止发生溜车。
▲实现永磁同步电机的短路发电机特性的简单方法是在通往电机的三相线路上加装一个接触器,当电梯的运行接触器断开后,通过这个加装的接触器把电机的三相定子绕组短接起来。
这样就实现了断电时对电机三相定子绕组的短接,也就是电梯行业叫的封星。
现把接触器的运行触点和短接定子绕组的触点集于一体的接触器,就称该接触器具有了能满足电梯需求的封星功能。
二.我公司新开发的静音交流接触器产品的特性■吸合噪音低,工作状态无噪音,可满足电梯行业要求噪音低的问题▲产品具有交流和直流两种控制方式;接触器线圈采用直流操作线圈交流控制时,通过整流来满足交流电源,消除了交流电的电磁噪音;▲产品铁芯采用电工纯铁、螺旋管结构,衔铁与磁轭吸合时接触面积小、吸合噪音小。
■可满足永磁同步电机的封星功能▲我公司实现永磁同步电机的封星采用两种方案,方案一:由一台封星接触器来实现,即运行触点和短接定子绕组的触点集于一体的接触器,称为封星接触器。
封星接触器由三常开触点和三常闭触点组成,在电梯停车时,三常开触点断开,三常闭触点闭合,当电梯开车时,三常闭触点先断开,再使三常开触点闭合。
正泰电器接触器产品综合样本接触器类Page B-085交流接触器( 续)Page B-076Page B-083CJ40系列交流接触器Page B-091CKJ5系列真空交流接触器CJX2系列交流接触器Page B-089CJT1系列交流接触器Page B-088CJ12系列交流接触器CJ19系列切换电容器接触器Page B-081 CJ20系列交流接触器交流接触器Page B-001 Page B-019 Page B-041 Page B-052 Page B-059 Page B-066 Page B-015 Page B-034 Page B-043 Page B-056 Page B-063 Page B-072 接触器类?交流接触器?直流接触器Page B-054 直流接触器Page B-094 CZ0系列直流接触器NC8系列交流接触器NC9系列真空交流接触器NC7系列交流接触器NC11交流接触器NC1系列交流接触器NC2系列交流接触器NC6系列交流接触器NCK3-25~40 空调用交流接触器NCH8家用交流接触器NCX1系列交流接触器CJX1系列交流接触器CJX1-??/N 系列机械联锁可逆接触器BNCK5系列空调用交流接触器Page B-049 NC3系列交流接触器Page B-085交流接触器( 续) Page B-076 Page B-083CJ40系列交流接触器Page B-091CKJ5系列真空交流接触器CJX2系列交流接触器Page B-089CJT1系列交流接触器Page B-088CJ12系列交流接触器CJ19系列切换电容器接触器Page B-081 CJ20系列交流接触器交流接触器Page B-001 Page B-019 Page B-041 Page B-052 Page B-059 Page B-066 Page B-015 Page B-034 Page B-043 Page B-056 Page B-063 Page B-072 接触器类?交流接触器?直流接触器Page B-054 直流接触器Page B-094 CZ0系列直流接触器NC8系列交流接触器NC9系列真空交流接触器NC7系列交流接触器NC11交流接触器NC1系列交流接触器NC2系列交流接触器NC6系列交流接触器NCK3-25~40空调用交流接触器NCH8家用交流接触器NCX1系列交流接触器CJX1系列交流接触器CJX1-??/N系列机械联锁可逆接触器BNCK5系列空调用交流接触器Page B-049NC3系列交流接触器1 适用范围 NC8系列交流接触器NC8系列交流接触器(以下简称接触器),主要用于交流50Hz(或60Hz),额定工作电压至690V,在AC-3/415V使用类别下额定工作电流至100A的电路中,供远距离接通和分断电路之用,并可与适当的热过载继电器组成电磁起动器以保护可能发生操作过负荷的电路,接触器适宜与频繁地起动和控制交流电动机。
CJX2系列交流接触器(以下简称接触器),主要用于交流50Hz(或60Hz),电压至690V,在AC-3、400(380)V使用类别下额定工作电流至95A的电路中,供远距离接通和分断电路、频繁地起动和控制交流电动机之用,并可与适当的热继电器组成电磁起动器以保护可能发生操作过负荷的电路。
符合标准:GB 14048.4、IEC 60947-4-1。
CJX2系列交流接触器1 适用范围2 型号及含义CJ X 2-□□ □□F4-□ □F5-□ □侧挂式1常闭辅助触头1常开辅助触头设计序号辅助触头组交流接触器企业特征代号N C F1-11C工作电压工作电流类别(A型适用于电流为09A~32A接触器,B型适用于电流为40A~95A接触器)设计序号浪涌抑制器SR 2 - □ / □触头数量,用数字表示10表示三常开主触头、一常开辅助触头(32A及以下)01表示三常开主触头、一常闭辅助触头(32A及以下)11表示三常开主触头、一常开一常闭辅助触头(40A及以上)04表示四常开主触头、08表示两常开两常闭主触头(除18A、32A以外)基本规格代号,用400(380)V、AC-3的额定工作电流数值表示设计序号小型交流接触器常闭辅助触头数量常开辅助触头数量辅助触头组0表示延时范围0.1s~3s2表示延时范围0.1s~30s4表示延时范围10s~180sT表示通电延时;D表示断电延时空气延时头空气延时头机械联锁机构热继电器限流触头组空气延时头辅助触头组SR2-A用于CJX2系列09A~32A交流接触器,具体规格有:SR2-A 24V~48V AC、DCSR2-B用于CJX2系列40A~95A交流接触器,具体规格有:。
静音交流接触器 在电梯行业内的应用
一.电梯行业发展现状及对接触器的需求要点
■要求接触器噪音小,满足无机房电梯的使用
▲现在楼宇建设为了减少公摊面积,尽量缩小客用电梯机房体积,电梯企业为此把制造无机房电梯作为发展趋势。
无机房电梯容易产生噪音,噪音来源主要是接触器的动作声音和电流噪音,为此接触器噪音小才能满足无机房电梯的要求。
电梯为接触器通常提供交流电源,目前减小接触器噪音的通行方式:一是接触器采用直流操作线圈通过整流满足电梯电源,以此来消除接触器工作时的电流噪音;二是减少接触器的动作噪音。
■要求接触器具有封星功能
▲随着稀土永磁材料的性能不断完善,永磁同步电机技术的发展,永磁同步无齿轮曳引电机在电梯上得到了广泛的应用。
永磁同步电机具有短路发电机特性,这一特性被广泛应用于电梯,主要起电梯停止时防止发生溜车。
▲实现永磁同步电机的短路发电机特性的简单方法是在通往电机的三相线路上加装一个接触器,当电梯的运行接触器断开后,通过这个加装的接触器把电机的三相定子绕组短接起来。
这样就实现了断电时对电机三相定子绕组的短接,也就是电梯行业叫的封星。
现把接触器的运行触点和短接定子绕组的触点集于一体的接触器,就称该接触器具有了能满足电梯需求的封星功能。
二.我公司新开发的静音交流接触器产品的特性
■吸合噪音低,工作状态无噪音,可满足电梯行业要求噪音低的问题
▲产品具有交流和直流两种控制方式;接触器线圈采用直流操作线圈交流控制时,通过整流来满足交流电源,消除了交流电的电磁噪音;
▲产品铁芯采用电工纯铁、螺旋管结构,衔铁与磁轭吸合时接触面积小、吸合噪音小。
■可满足永磁同步电机的封星功能
▲我公司实现永磁同步电机的封星采用两种方案,方案一:由一台封星接触器来实现,即运行触点和短接定子绕组的触点集于一体的接触器,称为封星接触器。
封星接触器由三常开触点和三常闭触点组成,在电梯停车时,三常开触点断开,三常闭触点闭合,当电梯开车时,三常闭触点先断开,再使三常开触点闭合。
此方案针对电梯有些特殊运行场合,避免故障发生,提高了常开、常闭触点间的转换时间差,增大了常闭封星触点的容量。
实现功能如下图所示:
CJX4-40DF
或CJX4-70DF
方案二:利用一台三常开接触器控制电机正常运转和一台两常开、两常闭的四极接触器来实现封星功能。
此方案可通过控制线路延时解决两接触器之间转换时间差较短的问题。
实现功能如下图所示:
以额定工作电流25A为例,应做如下选型:
三.产品介绍
■CJX4-09/95DT系列静音接触器产品简介
▲用途
CJX4-DT系列静音交流接触器(以下简称接触器),主要用于交流50Hz(或60Hz),额定绝缘电压为690V,额定工作电压至660V,在AC-3使用类别下额定工作电压为380V时,额定工作电流至95A的电路中,供远距离接通和分断电路之用,以保证可能发生操作过负荷的电路,还适用于机床控制电路中。
▲适用范围
静音交流接触器具有交流或直流控制,工作时无噪音等特点,广泛应用于电梯行业。
CJX4-DT系列静音交流接触器除了在电梯行业内的应用外,在中央空调螺杆机、静音空气压缩机等对噪音有限制要求的场合均能适应。
▲执行标准
GB 14048.1-2006低压开关设备和控制设备 第一部分:总则
GB 14048.4-2010低压开关设备和控制设备 第4-1部分:接触器和电动机启动器 机电式接触器和电动机启动器(含电动机保护器)
▲ 型号及含义
▲产品优特点
●工作状态无噪音,接通分断时噪音低;
●同一台产品可以实现交、直流两种控制方式;
●抗震动性能强;
●耐高、低温能力强,-40℃至60℃范围内可正常工作;
●产品内置了浪涌保护装置,适合频繁通断的使用场合;
●耐腐蚀能力强,TH产品通过了72小时盐雾试验;
●可与弱电流导通辅助触头组配合,使信号传递可靠;
●可加挂附件(侧挂、顶挂辅助触头组及空气延时头);
●防尘效果好;
●动作机构为直动式,触头为双断点;
●辅助触头设计为强制摩擦结构,有自洁作用。
▲磁系统
衔铁、磁轭采用电工纯铁棒。
其电磁性能良好,矫顽力地,导磁
率、饱和磁感高,磁性稳定,在磁
系统体积缩小的情况下提高了电磁
吸力,减小产品的体积,增加产品
的可靠性。
磁系统 ▲主要技术参数
0908DT 1210DT
1201DT
1204DT
2508DT
3210DT
3201DT
5011DT
5004DT
6511DT
6504DT
8011DT
8004DT
5008DT 6508DT 8008DT
2P+2R
3P+NO
3P+NC、
4P
2P+2R 3P+NO+NC、4P 2P+2R
25 40 50 80 80
12 25 - - 65
12 - 32 65 - 8.9 - 21 42 - 5.5kW - 15kW 30kW -
- 50 - - 10 - 1200 - - 600 100 - 80 60 - 1200 - 600 600 -
20 - 20 15 - 300 - 300 300 -
- 12 28 -
- 7.5 14 -
▲正常工作和安装条件
★正常工作条件
●周围空气温度-25℃~+60℃。
●安装地点的海拔不超过3000m。
●最高温度为+40℃时,空气的相对湿度不超过50%,在较低的温度下可以允许有较高的相对湿度,例如20℃时达90%。
对由于温度变化偶尔产生的凝露应采取特殊的措施。
●接触器安装地点的污染等级为3级。
★安装条件
●接触器的安装类别为Ⅲ类。
●接触器的安装面与垂直面的倾斜度不大于±5°。
●CJX4-09~38DT接触器可在35mm卡轨上或螺钉安装,CJX4-40~65DT接触器用螺钉安装。
▲ 外形及安装尺寸
CJX4-09DT/12DT/18DT/25DT/32DT/38DT
CJX4-
CJX4-4008DT/5008DT/6508D/8008DT/9508DT
▲
基本规格
A max
B maxa
C max
a
b
CJX4-09 DT /12 DT 120 CJX4-18 DT 46
79
125
30±0.5
60±0.5
CJX4-25 DT CJX4-32/38 DT
56 80 134 30±0.5 60±0.5
CJX4-4011/5011/6511 DT 76 CJX4-4004/5004/6504 DT 86 113 169 30±0.5 74±0.5 CJX4-4008/5008/6508 DT
86 113 178 30±0.5 74±0.5 CJX4-8011/9511DT
84.2 124 178 30±0.5 74±0.5 CJX4-8004/9504DT
84.2 106 30±0.5 74±0.5 CJX4-8008/9508DT 95
122
185
30±0.5
74±0.5
4011DT/5011DT/6511DT/8011DT/9511DT
4004DT/5004DT/6504DT/8004DT/9504DT
▲
接线图
CJX4-0910DT、1210DT
CJX4-1810DT、2510DT CJX4-3210DT、3810DT
CJX4-0901DT、1201DT CJX4-1801DT、2501DT CJX4-3201DT、3801DT
CJX4-4011DT、CJX4-5011DT CJX4-6511DT、CJX4-8011DT CJX4-9511DT CJX4-4004DT、CJX4-5004DT CJX4-6504DT、CJX4-8004DT CJX4-9504DT
CJX4-4008DT、CJX4-5008DT、 CJX4-6508DT、CJX4-8008DT、 CJX4-9508DT
CJX4-0908DT、 CJX4-1208DT、 CJX4-2508DT
■CJX4-40/70DF系列封星接触器产品简介
▲用途:
CJX4-40/70DF该系列产品主要针对电梯行业研发,在主回路系统中用于实现永磁同步曳引电机封星功能的专用接触器。
▲型号含义
▲产品技术参数
可接通最小负载 24V 10mA
额定控制电压Us:V AC/DC:24,48,110,220
吸合电压 (85%~110%) Us
线圈
释放电压 (10%~75%) Us
线圈功率(小于) 19 22
▲接线图
四.订货须知
▲在订货时须写明以下内容:
接触器的全称、型号、控制线圈的电压及类别以及订货数量。
例如:CJX4-2508 DT AC110V 50Hz,20台。
表示为额定电流25A的静音交流接触器,主触头为两对常开触头和两对常闭触头,线圈控制电压为交流110V,频率50Hz,订货数量为20台。