XEXT系列血液分析仪报警信息及其解释
- 格式:ppt
- 大小:7.42 MB
- 文档页数:91
a-pick up tube improper positionadjust pump head to tube x xx mm press blood flow key to confirm air detector not activated press air detector keyair leakage check fluid tubes connectionsattach fluid tubes press select to abort the testattach fluid tubes press select to start disinfb/acetate-pick up tube improper positionbattery failure change battery or press selectbicart emptied press select to confirmbicart holder not closed close or check bicart holderbicart not attached to holder attach or check bicartblood in priming detector function check stoppedblood leak detector failure clean and press blood leak keyblood pump cover not closed close blood pump coverblood pump overload in fch check the pump and press select blood pump overload press blood pump keyblood pump stop time expired start blood pumpbpm failure turn off bpmchem dis fill up phase completed place pick up tube in machine chemical fill up not sufficient check supply of disinfectantconnect concentrate when time to prepare machine for treatment decalcification required xx hours since last decalcificdialysis flow too lowdialysis fluid not ready for treatment fluid ready in xxx sdialysis fluid ready press bypass keydisconnect venous pressure press venous key to confirm disinfection required xx days since last disinfectionextra priming volume achievedfluid bypass time expired press bypass keyfluid path obstruction check fluid tubes and dialyzerfluid tube sensor test failed press select to confirmfluid tube sensor test attach fluid tubesfluid tube sensor test remove fluid tubesfluid tubes in safety bypass connect fluid tubes to dialyzerfluid tubes not in safety bypassfunction check restarted please waitheater efficiency not sufficient for proper disinfectionheparin pump overload check heparin syringe and line heparin set to zero press heparin key to confirmhigh conductivity not obtained check concentratehigh inlet water cond xx ms/cm check inlet waterhigh monitor temperature alarm turn off the monitor impossible time or uf setting adjust time or uf volume incorrect acidic concentrate check contrateincorrect bicarbonate conc check concentrateincorrect concentrate check concentrateincorrect dialysis fluid compositioninsufficient inlet pressure please check water supplylow battery power machine turns off within one minute negative uf rate check and press uf volumeno backfiltration warning press tmp to confirmno bpm values check bpm cuffno cuff attached attach or check bpm cuffonly blood monitor is running press select to start fluid part dlease wait 30 sec. to bypass dialysis fluidpower failure, battery operation battery operated for xx minutes ready for venous pressure test press venous key to start recovered from power failure press time key to confirm remove fluid tubes press select to abort the testsags test failedset dialysis flow not reached readjust flow or call servicetmp limits too wide press tmp key to adjustto empty bicart, press selectto end treatment, press isol ufand zero timeto obtain total uf volume isol uf must be startedto start the air detector test: fill the venous drip chambertoo high tmp required increase time or decrease uf volume treatment started no reset made press select if ok, else resetuf uf rate limit reached re-adjust time or uf volumeuf rate lower than minimum set adjust time, uf volume or min uf uf stop time expired press start/stop keyuf volume set to zero press uf volume key to confirmvenous low limit below +10 mmhg press venous key to adjust venous pressure limits too wide press venous key to adjust venous pressure test interrupted press select to confirm wrong disinfectant agent press select to restart disinfA-PICK UP TUBE IMPROPER POSITIONA管位置不对ADJUST PUMP HEAD TO TUBE X XX MM PRESS BLOOD FLOW KEY TO CONFIRM 改动了血泵管径,压血流量键确认AIR DETECTOR NOT ACTIVATED PRESS AIR DETECTOR KEY空气监测没启动,压空气监测键AIR LEAKAGE CHECK FLUID TUBES CONNECTIONS漏气,检查透析液管路接头ATTACH FLUID TUBES PRESS SELECT TO ABORT THE TEST接上透析液管路压箭头终止测试ATTACH FLUID TUBES PRESS SELECT TO START DISINF接上透析液管路压箭头开始消毒B/ACETATE-PICK UP TUBE IMPROPER POSITIONB管位置不对BATTERY FAILURE CHANGE BATTERY OR PRESS SELECT电池失效,换电池或压箭头键BICART EMPTIED PRESS SELECT TO CONFIRM干粉简排空,压键头确认BICART HOLDER NOT CLOSED CLOSE OR CHECK BICART HOLDER干粉支架未关好BICART NOT ATTACHED TO HOLDER ATTACH OR CHECK BICART干粉未接上支架,请接上BLOOD IN PRIMING DETECTOR FUNCTION CHECK STOPPED预冲探测器监测血或预冲探测器赃了BLOOD LEAK DETECTOR FAILURE CLEAN AND PRESS BLOOD LEAK KEY漏血测试失败,清洗并压漏血键BLOOD PUMP COVER NOT CLOSED CLOSE BLOOD PUMP COVER血泵门未关BLOOD PUMP OVERLOAD IN FCH CHECK THE PUMP AND PRESS SELECT自检时血泵卡死,检查血泵压箭头BLOOD PUMP OVERLOAD PRESS BLOOD PUMP KEY血泵卡死,压血泵键BLOOD PUMP STOP TIME EXPIRED START BLOOD PUMP血泵停止时间过长,启动血泵BPM FAILURE TURN OFF BPM血压计坏了,关闭血压计CHEM DIS FILL UP PHASE COMPLETED PLACE PICK UP TUBE IN MACHINE 消毒液吸满了,将吸液管放入机器内CHEMICAL FILL UP NOT SUFFICIENT CHECK SUPPLY OF DISINFECTANT消毒液不对,检测消毒液CONNECT CONCENTRATE WHEN TIME TO PREPARE MACHINE FOR TREATMENT 请接透析液DECALCIFICATION REQUIRED XX HOURS SINCE LAST DECALCIFIC需要脱钙DIALYSIS FLOW TOO LOW透析液流量太小DIALYSIS FLUID NOT READY FOR TREATMENT FLUID READY IN XXXs 透析液未准备好DIALYSIS FLUID READY PRESS BYPASS KEY透析液浓度好了,压旁路键DISCONNECT VENOUS PRESSURE PRESS VENOUS KEY TO CONFIRM取下静脉压保护器,压静脉压键确认DISINFECTION REQUIRED XX DAYS SINCE LAST DISINFECTION需要消毒EXTRA PRIMING VOLUME ACHIEVED预冲量到了FLUID BYPASS TIME EXPIRED PRESS BYPASS KEY旁路时间太长,压旁路键FLUID PATH OBSTRUCTION CHECK FLUID TUBES AND DIALYZER管路中有堵塞,检查管路和透析器FLUID TUBE SENSOR TEST FAILED PRESS SELECT TO CONFIRM旁路管位置感应器测试失败,压箭头确认FLUID TUBE SENSOR TEST ATTACH FLUID TUBES旁路管位置感应器,接上旁路FLUID TUBE SENSOR TEST REMOVE FLUID TUBES旁路管位置感应器,取下旁路FLUID TUBES IN SAFETY BYPASS CONNECT FLUID TUBES TO DIALYZER 旁路管在机器上,接上透析器FLUID TUBES NOT IN SAFETY BYPASS旁路管不在机器上FUNCTION CHECK RESTARTED PLEASE WAIT机器自检重新开始HEATER EFFICIENCY NOT SUFFICIENT FOR PROPER DISINFECTION热消毒功率不够,检查电压和保险HEPARIN PUMP OVERLOAD CHECK HEPARIN SYRINGE AND LINE肝素泵过载,检查针筒到底和管路夹死HEPARIN SET TO ZERO PRESS HEPARIN KEY TO CONFIRM肝素设定为零,压甘素键确认HIGH CONDUCTIVITY NOT OBTAINED CHECK CONCENTRATE高电导达不到,检查A液HIGH INLET WATER COND XX ms/cm CHECK INLET WATER进水电导太高HIGH MONITOR TEMPERATURE ALARM TURN OFF THE MONITOR机器高温报警,关机器IMPOSSIBLE TIME OR UF SETTING ADJUST TIME OR UF VOLUME时间或脱水设定不对,调节时间或脱水量INCORRECT ACIDIC CONCENTRATE CHECK CONTRATEA液不对INCORRECT BICARBONATE CONC CHECK CONCENTRATEB液不对INCORRECT CONCENTRATE CHECK CONCENTRATEA,B液都不对INCORRECT DIALYSIS FLUID COMPOSITION透析液的成分不对INSUFFICIENT INLET PRESSURE PLEASE CHECK WATER SUPPLY进水压不够LOW BATTERY POWER MACHINE TURNS OFF WITHIN ONE MINUTE后备电池电量低,1分钟后关机NEGATIVE UF RATE CHECK AND PRESS UF VOLUME负超滤率,检查脱水量设定并确定NO BACKFILTRATION WARNING PRESS TMP TO CONFIRM没有反超报警,压TMP(跨膜压)键确认NO BPM VALUES CHECK BPM CUFF血压计没压力,检查袖带NO CUFF ATTACHED ATTACH OR CHECK BPM CUFF血压计袖带没连接ONLY BLOOD MONITOR IS RUNNING PRESS SELECT TO START FLUID PART 只有血路部分正在运行,压箭头启动水路DLEASE WAIT 30 SEC. TO BYPASS DIALYSIS FLUID30秒后旁路正常运行POWER FAILURE, BATTERY OPERATION BATTERY OPERATED FOR XX MINUTES 无交流电,后备电池维持了XX分钟READY FOR VENOUS PRESSURE TEST PRESS VENOUS KEY TO START准备测静脉压,压静脉压键RECOVERED FROM POWER FAILURE PRESS TIME KEY TO CONFIRM非正常开关机,压TIME(时间)键确认REMOVE FLUID TUBES PRESS SELECT TO ABORT THE TEST旁路管被取下,压箭头取消测试SAGS TEST FAILEDSAGS开关测试错误SET DIALYSIS FLOW NOT REACHED READJUST FLOW OR CALL SERVICE设定的透析液流量达不到,重新调节TMP LIMITS TOO WIDE PRESS TMP KEY TO ADJUSTTMP(跨膜压)范围太宽,压TMP键调节TO EMPTY BICART, PRESS SELECT排空干粉筒,压箭头TO END TREATMENT, PRESS ISOL UFAND ZERO TIME治疗结束,压单超键TO OBTAIN TOTAL UF VOLUME ISOL UF MUST BE STARTED使用单超,才能达到总的脱水量TO START THE AIR DETECTOR TEST: FILL THE VENOUS DRIP CHAMBER装上静脉壶,开始预冲TOO HIGH TMP REQUIRED INCREASE TIME OR DECREASE UF VOLUMETMP(跨膜压)太高,增加时间或减少脱水量TREATMENT STARTED NO RESET MADE PRESS SELECT IF OK, ELSE RESET UF 治疗模式不是接台模式,可以压箭头,否则重新接台UF RATE LIMIT REACHED RE-ADJUST TIME OR UF VOLUME超滤率超极限,调节时间或脱水量UF RATE LOWER THAN MINIMUM SET ADJUST TIME, UF VOLUME OR MIN UF超滤率小于最小超滤率,检查时间、脱水量、最小超滤率UF STOP TIME EXPIRED PRESS START/STOP KEY脱水停止时间到了,压 START/STOP键UF VOLUME SET TO ZERO PRESS UF VOLUME KEY TO CONFIRM零脱水设定,压 UF VOLUME键VENOUS LOW LIMIT BELOW +10 mmHg PRESS VENOUS KEY TO ADJUST静脉压下限低于+10,压静脉压键调节VENOUS PRESSURE LIMITS TOO WIDE PRESS VENOUS KEY TO ADJUST静脉压范围太宽,压静脉压键调节VENOUS PRESSURE TEST INTERRUPTED PRESS SELECT TO CONFIRM静脉压测试中断,压箭头确认WRONG DISINFECTANT AGENT PRESS SELECT TO RESTART DISINF错误消毒剂,压箭头重新开始消毒。