电流互感器手册
- 格式:pdf
- 大小:883.20 KB
- 文档页数:56
电流互感器使用指南书秀修## Current Transformer User Guide (English)。
### Introduction.Current transformers (CTs) are essential components of electrical power systems, providing a safe and accurate way to measure high currents. This guide provides a comprehensive overview of CTs, their types, construction, installation, and applications.### Types of Current Transformers.Window-type CTs: These CTs have a window or opening through which the conductor passes. They are typically used for measuring currents up to 1000 A.Bushing-type CTs: These CTs are mounted on bushings in high-voltage equipment. They are used to measure currents up to 5000 A.Closed-core CTs: These CTs have a closed magnetic circuit, providing excellent accuracy and stability. They are used in metering and protection applications.Open-core CTs: These CTs have an open magnetic circuit that can be clamped around the conductor. They are used for temporary measurements and troubleshooting.### Construction of Current Transformers.CTs consist of a primary winding, a secondary winding, and a core. The primary winding is connected in series with the circuit being measured, while the secondary winding is connected to the measuring device. The core is made of ferromagnetic material, such as laminated iron or ferrite.### Installation of Current Transformers.Window-type CTs: The conductor is passed through the window of the CT. The CT should be installed in a location where it is protected from vibration and harsh environments.Bushing-type CTs: The CT is mounted on the bushing and connected to the primary conductor. The bushing must be properly rated for the voltage and current being measured.Closed-core CTs: The CT is installed on a busbar or cable, and the primary winding is connected to the busbaror cable. The CT should be installed in a location with sufficient space for cooling.Open-core CTs: The CT is clamped around the conductorat the desired measurement point. The CT should be secured firmly and the jaws closed completely.### Applications of Current Transformers.CTs are used in a wide range of applications, including:Metering: Measuring electrical current for billing purposes.Protection: Detecting overcurrent conditions andtripping circuit breakers.Power factor correction: Monitoring power factor and adjusting capacitors to improve power factor.Power quality analysis: Measuring harmonics, flicker, and other power quality parameters.### Safety Considerations.When working with CTs, it is crucial to follow proper safety precautions:Always wear appropriate personal protective equipment (PPE).Ensure that the CT is properly grounded.Never open the CT's secondary circuit while it is connected to the primary circuit.Use caution when working with high-voltage CTs.## 电流互感器使用指南(中文)。
—MANUALCurrent transformersUniversal Motor Controller UMC100.3GeneralCharacteristics• CT4L185R/4, CT4L310R/4, CT5L500R/4, CT5L850R/4 three-phase current transformers for usage with UMC and nominal motor currents > 63 A• Only four types for Ie up to 850 A• CT with linear characteristicsApprovalsAll current transformers have in combination with UMC100.3 the following approvals• ABS• ATEX• CCC• cULus• DNV - GL—Order dataType Rated primary current range I e Order codeCT4L185R/460 … 185 A AC1SAJ929500R0185CT4L310R/4150 … 310 A AC1SAJ929500R0310CT5L500R/4200 … 500 A AC1SAJ929501R0500CT5L850R/4400 … 850 A AC1SAJ929501R0850—Dimensionsin mm and inches—CT4L185R/4, CT4L310R/4—CT5L500R/4, CT5L850R/42C D C 342002F 0012FunctionsApplicationThe current transformers CT4L and CT5L are accessories for the ABB Universal Motor Controllers UMCxxx. The motor current flows through the current transformer. The UMC measures the secondary current (4 A at nominal current) and calculates the real current based on the parameter setting ‚Current Factor‘.More information how to set this parameter is available in the UMC manuals.When using the current transformers together with the voltage module VI150 or VI155 the wiring schema shown below must be used to ensure proper operation of the cos φ (and thereof the power calculation) and phase sequence functions.—Wiring scheme for using current transformers with UMC and VI15xL1 L2 L3UMCCT5L500R/4CT5L850R/4L1L2CT4L185R/4CT4L310R/4L1Technical dataData at T a = 25 °C and rated values, unless otherwise indicated—GeneralType CT4L185R/4CT4L310R/4CT5L500R/4CT5L850R/4 Rated primary current range I e60 … 185 A AC150 … 310 A AC200 … 500 A AC400 … 850 A AC Rated frequency50/60 HzRated secondary current 4 ARated burden30…60 mΩPerformance under short circuit conditions:I q = 100 kA/1000 V ACCoordination type 2I q: Rated conditional short circuit currentTolerance of tripping time of UMC100 (incl. total ranges of current,temperature 0-60 °C, frequency 45-65 Hz)UMC with external current transformer: ±14 %Accuracy class of the monitored current of UMC100(range 50 % to 200 %of I e)UMC with external current transformer: 4 %—Isolation dataRated impulse withstand voltage U imp8 kVRated insulation voltage U i1000 VPollution degree3Overvoltage category III—Standards / directivesProduct standard IEC60947-1IEC60947-4-1RoHS Directive2002/95/EC—Environmental dataAmbient air temperature Operation 0 ... +60 °CStorage-25 ... +70 °CVibration (sinusoidal) acc. to IEC/EN 60068-2-6 (Fc) 5 g / 10 .... 150 HzShock (half-sine) acc. to IEC/EN 60068-2-27 (Ea)15 g / 11 ms—General DataDegree of protection IP20Dimensions (W x H x D)See dimensional drawingMounting With screws (M5/M6)Mounting position AnyAltitude2000 m; 2000 - 5000 m refer to the UMC100.3 manual 2CDC135032D0204 Duty time100 %Rated continuous thermal current (I cth) 1.2 I eWeight 1.6 kg 1.5 kg 1.7 kg 1.9 kg—Electrical Connection SecondaryTightening torque terminals 1…60.8 NmCross section terminals 1…6Max. 6 mm2—Electrical Connection PrimaryMotor wire size To be defined acc. IEC/EN 60204Max. cross section See dimension drawingD o c u m e n t n u m b e r 2C D C 135027D 0201 R e v . D (02/2020)—ABB STOTZ-KONTAKT GmbH Eppelheimer Strasse 8269123 Heidelberg, GermanyYou can find the address of your local sales organization on the ABB homepage/lowvoltageAdditional informationWe reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document.We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents – in whole or in parts – is forbidden without prior written consent of ABB AG. Copyright© 2020 ABB All rights reserved。
海 川 金 瑞HJ-LCT零序电流互感器技术手册(HJ-LCT V2.0)保定海川金瑞电气有限公司目录1简介2型号说明3使用条件4产品类别及主要数据5安装6定制7零序电流互感器设计选型参考8定货须知9外形图及数据表1.简介我公司生产HJ-LCT系列、孔径φ80mm~φ240mm的零序电流互感器(电缆型),有各种容量、变比、准确限值系数的高精度零序电流互感器及与小电流接地选线装置、继电器等配套的高灵敏度零序电流互感器。
产品分整体式和组合式两类。
互感器采用工程塑料外壳,树脂浇注成全密封,外形美观、安装方便、节省安装空间,规格品种多,可适应各种保护装置的需要,和电力系统各种运行方式(中性点接地、中性点不接地、大电阻接地、小电阻接地、消弧线圈接地)的需要。
2. 型号说明HJ-LCT J XX A.B.C.JHJ-LCT J K XX A.B.C.J类别内孔直径(mm)组合式(开口式)接地保护电流互感器公司标志3. 使用条件3.1环境温度:最高温度+60℃ 日平均气温不超过+40℃ 最低气温-5℃;3.2海拔不超过1000m (高原使用时特殊定货);3.3相对湿度 < 85%。
4. 产品类别及主要数据4.1交流电压0.4KV以上(电缆);4.2电网频率50Hz;4.3同名端:一次由“L1”侧穿入,二次为“K1”;4.4型号及数据、外形尺寸见图表。
5.安装5.1整体式互感器安装要在敷设电缆前进行,电缆敷设时穿过互感器。
5.2开口式互感器安装不受电缆敷设与否的限制,具体安装方法如下:5.2.1拆下互感器“ K1 ”、“ K2 ”的联接压片。
5.2.2将互感器顶部两条内六角螺栓松开拆下,互感器就分成两部分。
5.2.3将互感器套在电缆上,把两个接触面擦干净,薄薄涂上一层防锈油,对好互感器两部分然后拧上内六角螺栓,互感器两部分要对齐以免影响性能。
5.2.4将联接片固定在“ K1 ”、“ K2 ”上。
5.2.5开口式互感器上下两部分不可与其他互感器互换。
220kV电流互感器使⽤说明书⼀、概述LVQB(T)-220W2(3)型电流互感器在额定频率50Hz、设备最⾼电压252kV的电⼒系统中作电⽓保护和测量⽤。
产品符合GB1208《电流互感器》国家标准。
SF6电流互感器特点:1、运⾏安全可靠,免维护、不燃烧、不爆炸;产品在线监测SF6⽓体压⼒,运⾏中可不停电补充⽓体。
2、⾼精度,计量级为0.2或0.2S。
3、动热稳定性好,低温升。
4、局部放电量在5pC以下,⽆介质损耗问题。
⼆、型号说明L V Q B (T) - □ W□污秽等级电压等级 kV带暂态保护绕组带保护绕组主绝缘介质为⽓体倒⽴式结构电流互感器三、使⽤条件1、安装场所:户外2、海拔:不超过2000m3、最⼤风速: 35m/s4、地震烈度:不超过9度5、污秽等级:Ⅲ级(Ⅳ级)及以下污秽地区6、环境温度:最低⽓温: -30℃最⾼⽓温: +40℃⽇平均⽓温不超过+30℃7、相对湿度:95%(20℃时)四、结构产品总体结构为倒⽴式结构。
由底座、瓷套、壳体及⼆次绕组等部分组成(见图1、图2)。
⼆次绕组位于壳体内,与⼀次绕组之间⽤SF6⽓体绝缘,并通过⽀持绝缘⼦固定到壳体上,其引出线通过底座内的⼆次接线端⼦引出供⽤户外接负载使⽤。
⼀次绕组通过串并联⽅式及⼆次绕组抽头可获得四种电流⽐。
壳体上⽅设置有压⼒释放装置。
瓷套采⽤⾼强瓷套(根据⽤户需要,也可采⽤硅橡胶复合绝缘套管),能够承受5倍于产品额定⽓压的内压作⽤⽽不破坏,通过瓷套的上、下法兰分别与壳体和底座牢固地联结。
瓷套外绝缘公称爬电距离为6300mm(7812mm),能适应Ⅲ级(Ⅳ级)污秽地区运⾏需要。
底座除起⽀撑设备、安装作⽤外,还设置有密度控制器、⼆次接线端⼦、SF6阀门及吸附剂等。
五、主要技术参数1、主要电⽓参数:见表⼀2、绝缘⽔平:额定短时⼯频耐受电压(⽅均根值) 460kV·1min或395kV·1min额定雷电冲击耐受电压(峰值1.2/50µs ) 1050 kV 或950 kV 3、SF 6⽓体额定压⼒ 0.40MPa (20℃) SF 6⽓体补⽓压⼒ 0.35MPa (20℃)4、产品年漏⽓率不⼤于1%5、产品内SF 6⽓体的含⽔量:出⼚值不⼤于250µL/L 运⾏值不⼤于500µL/L 6、产品局部放电⽔平:252kV (⽅均根值)下不⼤于10pC 175kV (⽅均根值)下不⼤于5pC表⼀主要电⽓参数注1、测量绕组(或保护绕组)的数量和准确级可根据⽤户需要制造,若⽆特别说明,制造⼚提供下列组合:0.5/0.5/10P15/10P15/10P15/10P15注2、测量绕组的仪表保安系数和保护绕组的准确限值系数可根据⽤户需要制造,若⽆特别说明,制造⼚提供下列参数:FS10和10P15。
零序电流互感器说明书
一、概述
我公司生产的零序电流互感器主要用于电力系统产生零序接地电流时,与继电保护装置或信号装置配合使用,使装置元件动作实现保护或监控。
互感器采用ABS工程塑料外壳,全密封树脂浇注而成,外形美观、安装方便、节省安装空间。
有各种容量、变比、准确限值系数的高精度零序电流互感器,产品分整体式和开启式两类,规格品种从孔径Φ40mm-Φ500mm,可适应各种保护装置的需要,和电力系统各种运行方式(中性点接地、中性点不接地、大电流接地、小电流接地、消弧线圈接地)的需要。
二、型号说明
三、外形尺寸图:
四、开孔尺寸及技术参数:(方形)
1、安装尺寸
注:120* 为特制
2、技术参数(特殊型号根据要求制作)
五、开孔尺寸及技术参数(圆形)
1、安装尺寸
注:Φ320--Φ500无塑料外壳,环氧树脂浇注、铁支架组成。
根据客户要求制作。
2、技术参数(特殊型号根据要求制作)
六、电缆与互感器规格选择参数。
KTC101-Z.14本质安全型电流互感器技术说明华宁电子生产分公司目录1 概述 (2)2 结构特征与工作原理 (2)3 尺寸及 (2)4 安装使用 (3)KTK101-Z.14本质安全型电流互感器技术说明1 概述1.1 适用围KTK101-Z.14本质安全型电流互感器适用于煤矿井下,有煤尘及爆炸性气体的环境下,用作电流检测。
可对外提供200-1000Hz标准模拟量输出。
1.2 使用环境和条件a)工作环境温度为-10℃~+40℃;b)周围空气相对湿度不超过95% (+25℃);c)大气压力为80kPa~106kPa;d)有甲烷和煤尘等爆炸危险的矿井中;e)无破坏绝缘的腐蚀性气体的矿井中;f)无剧烈振动和冲击的地方;g)允许有溅水的环境中。
1.3 防爆型式:矿用本质安全型,标志:ExibⅠ。
1.4 关联设备:KDW101矿用隔爆兼本质安全型电源。
1.5 配接设备:KTC101-Z主控制器。
1.6 功能:实现相线电流检测。
2 结构特征与工作原理2.1 结构线路板经灌胶处理由硬质塑料外壳制成。
2.2 工作原理电流互感器将线圈感应到的电流值转换成光耦隔离输出的无源脉冲频率,无源脉冲频率量为200Hz~1000Hz。
3 技术参数3.1 模拟量输出:输出频率:200Hz ~1000Hz,3.2 供电电源:工作电压: DC 12V-DC 18V ;3.3 检测围:检测围:0-400A4 外形输出电源公共图1外形图5 安装使用5.1 把互感器穿入磁力接触器接线腔里的三相动力电缆中的任意一相,然后用三芯信号水线过喇叭嘴引到控制器或下位机输入端子排上,把信号传给控制器并显示其电流。
5.2 注意:1 检测电流应大于10安培,电压小于6000V 。
2 互感器上的线在磁力启动器接线腔室中一定要固定牢固,且一定要远离动力电缆,远离其他裸露带电部件;3 安装互感器时,不能直接将互感器套到裸露的动力电缆外面,动力电缆外面应有外皮防护,如没有外皮的话,应从其它电缆上剥一段外皮,套在裸露的动力电缆上,再安装互感器;4 互感器要安装牢固,保证其不能在电缆上来回滑动。
电流互感器维修手册电流互感器是一种常见的电力系统设备,用于测量和监测电流。
在使用过程中,由于各种原因,互感器可能会出现故障或需要维修。
本手册旨在为用户提供有关电流互感器维修的详细说明和指导,以确保设备正常运行和延长使用寿命。
第一部分:维修前准备在进行电流互感器维修之前,需要做好以下准备工作:1. 安全措施:在进行任何维修操作之前,必须确保工作场所的安全。
必须穿戴个人防护装备,如安全帽、耳塞、护目镜等。
2. 工具准备:准备好适合维修工作的工具和设备,如螺丝刀、扳手、万用表等。
确保工具完好无损且符合操作规范。
3. 检查互感器:在维修开始之前,必须对互感器进行外观检查和功能测试。
检查互感器外壳、连接器是否有损坏,并使用万用表测试互感器的输出是否正常。
第二部分:常见故障及处理方法在电流互感器的使用过程中,可能会遇到以下常见问题及其解决方法:1. 输出电流异常:互感器输出的电流不稳定或偏离预期。
解决方法是检查互感器的连接器是否松动,确认输入端和输出端是否正确连接。
2. 外壳损坏:互感器外壳存在破损或者腐蚀。
解决方法是更换互感器的外壳,并确保新外壳具有良好的绝缘性能。
3. 磁芯短路:互感器的磁芯可能会发生短路故障,导致输出信号异常。
解决方法是检查磁芯状态并进行修复或更换。
4. 线圈断路:互感器线圈可能会发生开路,导致输出信号丢失。
解决方法是通过检查线圈连接情况并进行修复或更换来解决问题。
5. 温度过高:互感器在工作过程中产生的过多热量会影响其性能和寿命。
解决方法是通过增加散热设备或调整负载来降低互感器的工作温度。
第三部分:维修注意事项在进行电流互感器维修时,请注意以下事项:1. 细致仔细:在进行任何维修操作时,务必细致仔细,确保按照正确的操作步骤进行。
不要慌张或马虎,以免引起更严重的问题。
2. 提前备件:在维修开始前,根据互感器的型号和需求,准备好可能需要更换的备件。
这样可以在维修过程中节省时间并确保维修顺利进行。
3.1 安装场所:户内。
3.2 环境温度:-5℃~40℃。
3.3 环境湿度:相对湿度不大于80%。
3.4 海拔高度:不超过1000m。
3.5 大气条件:大气中无严重污秽。
型电流互感器是我公司开发的拥有自主知识产权的产品,适0.66kV及以下,额定频率为50Hz的交流电路中作电流、电能的测量和继电保护用,采用塑壳式绝缘,体积小、重量轻,适合任意方向安装,互感器中间留有窗口,可供母排或电缆穿过。
符合标准:GB 1208。
NLH1-0.66系列电流互感器用于户内、供额定电压为NLH1-0.66N LH 1-0.66(kV)额定电压设计序号电流互感器企业代号4 主要技术参数及外形安装尺寸35型50型55555555555555555555555555555555555555151010655322111110/515/520/525/530/540/550/575/5100/5100/5150/5200/5250/55555555555551 适用范围2 型号及含义3 正常工作条件和安装条件1020202011111111000/51200/51500/52000/5102020205101010202020510101020202051010600/5750/5800/551010 订货时请提供:5.1 产品型号;5.2 额定电流比;5.3 额定负荷及准确级;5.4 如有特殊要求时,可与厂家协商定制。
101010102020202020111111111600/5750/5800/51000/51200/51500/52000/52500/53000/5101010102020202020101010102020202020100型1010101020202020205 订货须知。
电流电压互感器通用说明书一、执行标准1、电流互感器符合国家标准GB1208-1997电流互感器的规定;2、电压互感器符合国家标准GB1207-1997电压互感器的规定;二、使用条件除另有说明外,互感器应满足下列使用条件;1、环境温度:普通型为+40℃~-15℃;高原型为+25℃~-15℃;日平均气温不能超过30℃;2、安装在相对湿度不大于85%的地区;3、海拔:普通型≤1000m,高原型≤4000m;4、大气中无严重污秽及侵蚀性、放射性及爆炸性气体存在;5、不能安装在有剧烈震动和撞击的地方;6、电流互感器允许在倍的额定电流下长期运行;7、电压互感器允许在倍的额定电压下长期运行;8、耐热等级E级;三、注意事项1、电流互感器一次有电流通过时,二次绕组不得开路,否则二次产生高压,对产品性能和人身安全有影响;2、电压互感器二次绕组不得短路,否则互感器将被烧毁;3、一次绕组的重复工频耐压试验应在规定电压值的80%下进行;四、使用说明1、保护用电流互感器准确级代号在GB1208-64标准中规定过流保护为3级,差动保护为D级,在GB1208-75标准中规定为B级,GB1208-87和GB1208-1997标准中规定:对保护用电流互感器,准确级以该准确级在额定准确限值一次电流下的最大允许复合误差的百分数标称,其后标以字母“P”表示保护,保护用电流互感器的标准准确级为5P和10P;例:5P10,后面的10表示其准确限值系数;相似于老标准的10%倍数2、电压互感器接地保护用的绕组以往称为“零序电压线圈”,其准确级标注为3B和6B;3和6表示误差限值,B表示保护;GB1207-1997中规定:保护用电压互感器的准确级,以该准确级在5%额定电压到额定电压因数相对应的电压范围内最大允许电压误差的百分数标称,其后标以字母P,保护用电压互感器的标准准确级为3P和6P;。