USB Fast charge tester FNB58USB快充测试仪 FNB58目 录
一、版本与更新01
二、概述01
三、注意安全事项01
五、 外观结构03
六、 技术指标044.0.1 电压电流类02
4.0.2 快充触发类034.0.3 线材鉴别类02
4.0.4 杂类03四、性能描述027.0.1 简洁页面
05
7.0.2 监测页面05
7.0.3 波形页面06
7.0.4 应用页面06七、主页面058.0.1 自动检测07
8.0.2 PD触发器07
8.0.3 小米PD触发器08
8.0.5 QC3.0触发088.0.4 QC2.0触发08
8.0.6 FCP触发09
8.0.7 SCP触发09
8.0.8 AFC触发098.0.9 VOOC/WARP触发09
8.0.10 SVOOC 1.0/SVOOC 2.0触发09八、快充应用
06
10.0.1电缆电阻检测11
10.0.2PD监听器12
10.0.3PD转换器13
10.0.4USB-C电子标签13十、工具箱119.0.1能量统计10
9.0.2电池容量计算10
9.0.3离线记录10九、能量统计09十二、升级固件说明17十三、常见问题解析1811.0.1通用
16
11.0.2记录16
11.0.3触发
17
11.0.4系统
17
11.0.5关于17十一、设置1510.0.7模拟APPLE 2.4A15141410.0.5读取DASH线缆
10.0.6模拟DASH一、版本与更新
由于仪表功能极多且软硬件更新频繁,说明书随时可能更新,请知悉。请在官网上获取最新的更新信息。
二、概述
FNB58 USB测试仪是一款高可靠性、高安全性的USB电压电流检测表及移动
通信终端快充触发仪。具有2.0寸全彩超宽视角TFT LCD显示屏及集成USB-A、
Micro-USB、Type-C接口。使用外置16位ADC,PD协议物理芯片。可用于测量
USB接口、手机充电器、U盘等产品的供电或耗电情况;可用于测量手机充电
《Platform Flash PROM User Guide》中文版
FPGA的配置分为主串行和从串行两种,差别在于时钟源不同。nCF为高时
PROM的DO数据有效,nCE和OE使能。P24和26介绍了接线图和引脚功能。
原型开发优势
每写一次可以有4套不同的程序进行测试。
板子测试配置或安全升级
设计的版本中写有诊断程序,如果发现原程序不满足要求,可以调用符合要
求的程序重新执行,节省了调试时间。PlatForm具有备份程序的功能。
防止不完整或损坏数据
FPGA的所有IO口在DONE为低电平时均不可用,PlatForm满足这个要求。
为什么使用内部解压或晶振
Platform PROM片上解压使得用户可以多存储50%的数据。
Platform PROM提供20MHz或者40MHz(默认)的时钟用于将配置数据从
PROM送入FPGA。内部晶振,特别是40MHz的操作只应用于解压模式。否则,
FPGA的CCLK或者外部晶振会用于驱动。PROM的解压输出数据速率为内部
时钟的一半,换言之,解压数据流配置时间是非压缩数据流的两倍。如果需要快
速配置,FPGA的BitGen-g compress方式可以作为压缩模式。
时钟
CLKOUT信号在配置过程中,且在nCE低、OE/nRESET高时有效;无效时
呈高组态并且需要外部上拉以避免不确定状态。时钟速率可以配置,默认为
1MHz,可以为1,3,6,12等,XCFxxS最大为33MHz。
PROM文件生成和烧写
.bit(Bitstream)文件为输入数据流,.mcs文件为输出数据,.cfi文件为配置
格式信息文件。.bit文件为FPGA使用的二进制数据,.mcs文件为PROM运行文
件,.cfi(Configuration format information)文件名字与前两者根目录相同。标准
的PROM文件为前两者。在XCFxxP系列PROM使用多版本程序设计、CLKOUT、
FCP03电梯控制器
用户手册(简明版)
杭州菲康电子科技有限公司
杭州市余杭中泰工业园振东路2号 邮编:311121
TEL:0571-8863 4333 8863 4018 FAX:0571-8863 4019 FCP03 电梯控制系统用户手册
1 适用范围:
FCP03电梯控制器广泛适用于变频电梯、液压电梯、以及双速电梯。
版权声明:
《FCP03电梯控制器用户手册》V3.50
版权所有,保留一切权利。
产品如果有功能、软件和设计上的改动,将尽可能通知用户。请客户注意自己使用手册的版本和日期,及时和我们或者和分销商联系,获得最新版本的用户手册。
FCP03 电梯控制系统用户手册
2 目 录
第一部分: 系统简介
1.1 系统组成„„„„„„„„„„„„„„„„„„„„„„„„„„„3
1.2 性能特点„„„„„„„„„„„„„„„„„„„„„„„„„„„4
1.3 FCP03 电梯控制器主要功能„„„„„„„„„„„„„„„„6
第二部分: 控制器
2.1 外观„„„„„„„„„„„„„„„„„„„„„„„„„„„„„8
2.2 端子介绍„„„„„„„„„„„„„„„„„„„„„„„„„„„8
2.2.1 电气指标„„„„„„„„„„„„„„„„„„„„„„„„„„8
2.2.2 端子顺序约定„„„„„„„„„„„„„„„„„„„„„„„8
2.2.3 J1端子(输入口)„„„„„„„„„„„„„„„„„„„„„„9
2.2.4 J2端子(输入口)„„„„„„„„„„„„„„„„„„„„„„9
12
1-800-735-6200
Features■250W, 500W, 750W, 115/230VacStrappable Single-Phase■1.5, 3, 5 kW, 208Vac Three-Phase■20-50 mS Holdup■UL, CSA, TÜV, VDE, BABT■FCC/VDE Class B (single-phase)■FCC/VDE Class A (three-phase)■BUS OK, AC OK, DC OK StatusSignal■96-98% Efficiency■PC and Chassis Mount■VI-26X, VI-J6X Series Compatible ■CE MarkedProduct HighlightsFrom AC line in, to highly regulated DCout, Vicor offers the total design solutionthrough a complete family of off-line frontend and DC-DC modular power components.Vicor’s family of off-line front endsinterface VI-260 and VI-J60 seriesDC-DC converters, and MegaMods, to100, 115, 230 or 240Vac single-phase and208Vac three-phase mains. In addition,front ends provide conducted EMI/RFIfiltering to FCC/VDE (Class B single-phase, Class A three-phase), transientsurge protection, active inrush limiting, aBUS OK status output (suitable forcontrolling Vicor DC-DC convertermodules via their Gate In pin) and an ACOK status output for system use in theevent of loss of the AC line.Operating Temperature(Free Convection)C: 0°C to +50°C (750W: +45°C)I: -20°C to +50°C (750W: +45°C)Storage Temperature-40°C to +80°COff-Line Front Ends