给排水计算表
- 格式:xlsx
- 大小:191.86 KB
- 文档页数:6
用水每户用水最高日用水小时户型内
户数人数用水定额总人数变化给水当量
(户)(人)(L/人.d)(人)系数数量当量数量当量数量当量数量当量数量当量数量当量数量当量
q0mKhN
g
1厨1卫0025002.510.75011110.7520.511014.5
1厨2卫500420020002.520.75111110.7520.511016.25
1厨3卫0025002.530.75111120.7530.511018.25
1厨4卫0025002.550.75411110.7540.5110112.5
1厨5卫0025002.560.75511110.7550.5110114.75
1厨6卫0025002.570.75611110.7560.5110117
1厨1卫0025002.510.75011110.7520.511014.5
1厨2卫280420011202.520.75111110.7520.511016.25
1厨3卫0025002.530.75111120.7530.511018.25
1厨4卫0025002.550.75411110.7540.5110112.5
1厨5卫0025002.560.75511110.7550.5110114.75
1厨6卫0025002.570.75611110.7560.5110117
1厨1卫0025002.510.75011110.7520.511014.5
1厨2卫24042009602.520.75111110.7520.511016.25
衛生器具
洗臉盆浴盆洗滌盆淋浴器大便器洗衣机浇花龙头
分区
住宅类分区给水总流量计算表(分区
1区
2区
住宅类型
1厨3卫00s02.530.75111120.7530.511018.25
1厨4卫0025002.550.75411110.7540.5110112.5
1厨5卫0025002.560.75511110.7550.5110114.75
1厨6卫0025002.570.75611110.7560.5110117
40802502.5
注:表格中为需填写或应根据实际情况调整的计算参数。
双轮
泵
注:1、αc查建筑给水排水设计规范GB 50015-2003附录C中表C所得;
2、各管材的直径是根据设计秒流量查手册相应表格所得。
3区
办公楼采用屋顶水箱供水,地下室设置工频泵7A区水泵扬程7+150+20=1777A区流量按最大时流量确定=90立
时=25L/s
7C区水泵扬程7+100+20=127
7A区流量按最大时流量确定=108
小时=30L/s
8A区水泵扬程7+100+20=127
8A区流量按最大时流量确定=45立
时=13L/s
L=2800,L8=2450,H1=220,H2=350,H3=380基础2720*1120*500,L1+L2=1270+562L=3400,L8=3132,H1=220
基础3330*1145*500,L1+L2=1220+5
消防转输泵XBD12/80-200D 一用一备132KW7+85+25=1177+100+30+35=17低区消火栓泵XBD18/40-
110KW
室外消火栓泵XBD6/40-150
高区消火栓泵XBD12/40-15
50+30+35=115
7+30+15=52
L=2190,L8=1965,H1=120
基础2170*1055*500,L1+L2=820+4
计算管
段
用水最大用水时平均平均计算管段设计铸铁管
给水当
量
时间平均出流概率出流概率同时秒流量公称直径流速
总数(h)出流概率对应系数出流概率(L/s)(mm)(m/s)
NgNgTU0=q0*m*Kh/(0.2*Ng*T*3600)U0(总)αc(总)U=(1+αc(Ng-1)0.49)/Ng1/2qg=0.2*U*N
g
0240.0000
3125241.8519
0240.0000
0240.0000
0240.0000
0240.0000
0240.0000
1750241.8519
0240.0000
0240.0000
0240.0000
0240.0000
0240.0000
1500241.8519
0.953125.001.85190.009600.02716.72150
11.48
1001.46
总当量
(分区流量选泵用)
1750.001.85190.009600.033
024#VALUE!
0240.0000
0240.0000
0240.0000
6375.00242.3148#VALUE!0.012524486
#VALUE!
100######
15.97
1501500.00#VALUE!#VALUE!#VALUE!=90立方/小=25L/s主泵采用二用一备KQDW80-20*9-Ⅱ 工作工况 Q=46.8m³/h H=183m N=45KW定=108立方/时=30L/s主泵采用二用一备KQDW80-20*7-Ⅱ 工作工况 Q=55m³/h H=133m N=37KW=45立方/小=13L/s主泵采用一用一备KQDW80-20*7-Ⅱ 工作工况 Q=50m³/h H=140m N=37KW1=220,H2=315,H3=36530*1145*500,L1+L2=1220+500L=3400,L8=3132,H1=220,H2=315,H3=365 基础3330*1145*500,L1+L2=1220+500低区喷淋泵XBD18/40-150D 一用一备 110KW7+100+30+40=17735=1728/40-150D 一用一备110KW0.90
7A栋避
难层
7A栋避难层
0-150D 一用一备 37KW
40-150D 一用一备 75KW高区喷淋泵XBD12/40-150D 一用一备 75KW
=11550+30+40=120
=52
1=120,H2=315,H3=365
70*1055*500,L1+L2=820+470