周珊珊郑希源 (济南市锅炉压力容器检验研究所,济南250002) 

摘 要:电梯选型配置问题是个十分有实际意义的话题。本文结合作者多年来检测检验电梯的经验, 浅谈几点选型配置应注意的问题。 关键词:电梯的选型输送能力安全可靠性先进性舒适性 

Shallowly Discussed the Elevator Shaping Should Pay Attention Questions ZHOU Shanshan ZHENG Xiyuan (Jinan Boile And Pressvre Vessel Inspection Research Instisute,Jinan 250002) Abstract:The elevator shaping disposition question is ten points has the practical significance the topic,This article has unified the author for many years to examine examines the elevator the experience,shaHowly discussed several shaping dispositions should pay attention question. Key words:Elevator shaping,Delivery capgcity,Security reliability,Advanced,Comfortableness 

随着我国经济的发展,高楼大厦不断增加,人们 对电梯的选型越来越重视,近年来房地产高层住宅 的大量涌现作为上下运输的交通工具,电梯越来越 引起社会的关注,因此电梯选型配置问题是个十分 有实际意义的话题。本文结合作者多年来检测检验 电梯的经验,浅谈几点选型配置应注意的问题。 1电梯应具有一定的输送能力 电梯在每天运行过程中,会出现几次乘梯高峰, 输送能力能满足5min高峰期的乘梯要求,就可以认 为电梯的选用是合理的,设电梯5min内的输送能力 为Q,其额定乘客人数为M,并估计平均每次实际乘 梯人数为0.8M,电梯往返一次需要的运行时间为t (包括运行时间和在各楼层的停靠时问),共有n台 电梯,显然有Q=240 Mn/t。 对于高层办公楼和住宅楼,可以按建筑面积为 大小初定电梯台数。电梯的额定载重量一般为 1000kg即13人,额定载客人数太小就要增加电梯或 提高电梯速度。太大则停层概率高且平常运行时浪 费很大。台数和载客人数决定后就可以按5min的输 送能力要求标出电梯应具有的运行速度,如果不理 想可以回头调整电梯数量或乘载能力。 习惯上把运行速度小于lm/s的电梯叫低速, 1~2m/s之间为中速,2m/s以上为高速。那么是不是在 电梯数量及载重量确定的情况下速度越高越好呢, 其实不然,确定电梯运行速度还要考虑楼层高度,停 层站数及调度技术等方面的内容,所以建设单位一 定要克服片面认为高速电梯一定会缩短乘梯时间, 提高输送效率的思想。 表1中列出了各种速度电梯的起动加速与停靠 减速所需的时间与高度,表2是这些运行一定高度 所需要的时问,这个时间是电梯直达时间 表1各种速度电梯的启动加速与停靠减速时间与速度 

额定速度 1.0 1.6 2.5 3.0 3.5 4.0 m・s一  ̄Jfl(减)速 度m・s 0.5~1.5 0.5~1.5 0.7~1.5 0.7~1.5 0.7~1.5 0.7~1.5 

加(减)速 时间t/s 4.0~1.4 6.4~2.2 7.2-3.4 8.6~4.0 10.0~4.6 1 1.4 ̄5.4 

加(减)速 距离m 2.O~1.2 5.4~2.2 9.0 4.4 1 3.O~6.O 1 7.6 ̄8.0 22.8—11.O 

2需要着重考虑的技术性能 电梯主要以运输载人为主,电梯安全可靠性是 非常重要的,在资金满足的前提下应采用先进的舒 适的产品。 

73 维普资讯 http://www.cqvip.com 表2电梯运行一定高度所需要的时间 

梯速(rrds2) 梯速(m/s2) 

层高 1.0 1.6 2.5 3.0 3.5 4.0 层高 2.5 3.0 3.5 4.0 

3 5.0 4.9 4.1 4.1 4.1 4.1 93 40.8 35.3 31.5 29.0 l 6 8.0 7.0 5.9 5.9 5.9 5.9 96 42.8 35_3 31.5 29.0 

9 11.0 8.9 7.2 7.2 7.2 7.2 99 43.2 37.3 333 30.5 12 14.0 10.8 8.4 8.3 8.3 8_3 102 44.4 38.3 34.1 31.2 

15 17.0 12.7 9.6 9.3 9-3 9.3 105 45.6 39-3 35.0 32.0 

18 20.0 14.5 10.8 10.3 10.1 10.1 108 46.8 40.3 35.8 32.7 

21 23.0 16.4 12.0 l1.3 11.0 11.0 111 48.0 41-3 36.7 33.5 

24 26.0 18-3 13.2 12-3 l1.8 11.7 114 49.2 42.3 37.5 34.2 

27 29.0 20-2 14.4 13.3 12.7 12.5 117 50.4 43.3 38.4 35.0 30 32.0 22.1 15.6 14.3 13.5 13I2 120 51.6 44-3 39.3 35.7 

33 35.0 24.0 16.8 15-3 14.4 14.0 123 52.8 45.3 40.1 36.5 

36 38.0 25.9 18.0 16.3 15-3 14.7 126 54.0 46.3 41.0 37I2 

39 41.0 27.8 19.2 17_3 16.1 15.5 129 55.2 47.3 41.8 38.0 

42 44.0 29.7 20.4 18I3 17.0 16.2 132 56.4 48.3 42.7 38.7 

45 47.0 31.6 21.6 19.3 17.8 17.0 135 57.6 49.3 43.5 39.5 48 50.0 33.4 22.8 20.3 18.7 17.7 138 58.8 50-3 44.4 40.3 

51 53.0 35.3 24.0 21.3 19.5 18.5 t41 60.0 51_3 45.3 41.0 

54 56.0 37.2 25.2 22.3 20.4 19-2 144 52-3 46.1 41.7 

57 59.0 39.1 26.4 23_3 21-3 20.0 147 53-3 47.0 42.5 

60 41.0 27.6 24.3 22.1 20.7 150 54.3 47.8 43.2 

63 42.9 28.8 25.3 23.0 21.5 153 55.3 48.7 44.0 

66 44.8 30.0 26_3 23.8 22.2 l56 56.3 49.5 44.7 69 46.7 31.2 27_3 24.7 23.0 159 57_3 40.4 45.5 

72 48.6 32.4 28_3 25.5 23.7 162 58_3 51_3 46.2 

75 50.5 33.6 29.3 26.4 24.5 165 59.3 52.1 47.0 

78 52_3 34.8 30.3 27_3 25.2 168 60.3 53.0 47.7 

81 54.2 36.0 31.3 28.1 26.0 171 53.8 48.5 

84 56.1 37.2 32_3 29.0 26.7 174 54.7 49.2 87 58.0 38.4 33.3 29.8 27.5 177 55.5 50.0 

90 59.9 39.6 34.3 30.7 28.2 270 

74 2.1司靠性 可靠性是指电梯系统在规定的时间内保持规 定功能的能力,是建立在大量统计数据基础上的概 率概念。据济南市电梯使用情况而言,每年进行年 检时,大的机关宾馆,楼层在20层左右,运行次数 在180万次左右的很多,可见运行频率是相当高 的。如果电梯的可靠性较差,带来的后果是非常严 重的。不仅耽误正常使用,也要增加维修费用。由于 电梯的环节较多,故障点太多,因而绝对无故障的 电梯是不存在的。而影响到人生安全的环节如安全 钳、限速器、安全触板、防止门夹人保护系统等要绝 对不能失灵。 2.2先进性 电梯的先进性目前主要体现在拖动与控制技 术方面。我们以前了解的双速、调压调速、直流电梯 不再讨论。当今人们主要选型为变频变压调速 fVVVF)电梯,国内几个知名生产厂都开发研制了 具有自己特点的变频变压调速fVVVFl电梯,这种 类型是当今主导产品,是人们选型的重点。 2.3舒适性 舒适感主要是指电梯的加速度、运动、震动、声 音等方面,主要通过人们乘坐电梯自身的感受来决 定的。 在电梯选型时可靠性是最为重要的。国标 GB10058中规定:电梯运行6万次故障小于5次是 合格品,少于2次为一等品,少于一次为优等品。电 梯产生故障的环节很多,而这些故障主要是电气故 障,电梯故障主要是由于电气触点或安全触点来控 制,电气或安全触点该断开而不断开,该闭合而不 闭合时,电梯就会出现安全故障,动作最频繁是门 锁触点,电梯每次起动、停站,层门必须关闭,触电 闭合,开门触点断开,电梯运行过程才能完全,门机 运行次数恰是电梯运行次数的两倍。电梯进人人们 生活已经有很长一段时间,也逐步认识到了门机系 统的重要性,如配置较高,一般选用进口变频门机。 电梯选型需要考虑的方面很多,其主要考虑机 组、控制柜、开门机3大件,这三大件对整个电梯性 能方面起着重要的作用,建设单位应根据基建投资 购置电梯资金的实际情况统盘考虑,不要刻意追求 某一个方面,否则会导致选型失败,造成经济损失。