ELx405洗板机
- 格式:pdf
- 大小:142.02 KB
- 文档页数:2


waterse2695各部件冲洗及排⽓简单操作
Waters液相主机操作及其注意事项
1.先开电脑等xp系统运⾏起来后再开仪器,防⽌仪器找不到电脑。
2.纯绿⾊管路为进样针外壁清洗管路,溶剂应为流动的组分,但不能含有缓冲盐。
我⾃⼰⼀般⽤的是甲醇:⽔(80:20),如有缓冲液流动相时,调⾼⽔项⽐例。
⽬前还没有发现什么问题
3.⽩绿⾊管路为泵头清洗管路,流动项⽆缓冲盐时可不⽤,但有缓冲盐是必须有溶液,为20%甲醇溶液或者10%都可以,其实纯⽔最好,加甲醇是为了防腐。
4.在线过滤器筛板如堵塞先70℃-80℃热⽔超声半⼩时,再甲醇超声半⼩时。
5.压⼒不稳时考虑单向阀的问题,清洗同在线过滤器清洗,拆装时注意箭头⽅向,如还不⾏,晃动,如没有响动,宝⽯球不能动,报废处理。
6.显⽰Idle时,仪器⾃检完成
各部分的冲洗及排⽓操作
1.泵头清洗:Diag→Prime Sealwsh→1-2分钟后→Halt停⽌→Close关
2.进样针外壁清洗:Diag→Prime Ndwsh ⾃动计时1-2次→Exit
3.更换流动相后管路排⽓
Menu/Stalus A路100%→Direct Function→3.Wet Priwce→OK→7.5ml/min、2min→OK
清洗其他管路先把A调成0,往后顺延
4.注射器若有⽓泡,主页⾯调⾄显⽰流动相⽐例界⾯Menu/Stalus
Direct Function →4. Purge Injector 时间默认,重复1-2次直⾄⽆⽓泡。
此项所⽤液体为在流动相⽐例⾃⼰设定,⼀般⽤50%甲醇⽔。
SPARE PARTS CATALOGFrom Ser. nr.: 227COMPACT RACK TYPE DISHWASHERBrand:Country:Models Affected:44”66”Electrolux Part NumberDescription 534034ECRT66R208534035ECRT66L208534036ECRT66R240534037ECRT66L240534040ECRT44R208534041ECRT44L208534042ECRT44R240534043ECRT44L240EUSA-CANADAINDEXDrawing Description Page VIEW OF MODULES COMPOSITION3 ill.595669M00p1Main view, Wash + Rinse for 44 inch machine4 Spare parts list5 ill. 595669M00p2Main view, Prewash for 22 inch module9 Spare parts list10 ill. 595669M00p3Wash hydraulic circuit, Wash + Rinse for 44 inch module12 Spare parts list13 ill. 595669M00p4Prewash hydraulic circuit, Prewash for 22 inch module15 Spare parts list16 ill. 595669M00p5Rinse hydraulic circuit, Wash + Rinse for 44 inch module18 Spare parts list19 ll. 595669M00p6Electrical components, Wash + Rinse for 44 inch module21 Spare parts list22 ill. 595669M00p7Electrical components, Prewash for 22 inch module25 Spare parts list26From Ser. nr.: 227Doc. Nr.: 595669M00VIEW OF MODULES COMPOSITIONFrom Ser. nr.: 227Doc. Nr.: 595669M00From Ser. nr.: 227Doc. Nr.: 595669M00101a108a108b103104b106173119109110111112116115118123125127133135136139b105117117114114c114a114f114b121120124125132122127102147140a 140b140c145109162144142137146148149152153158155113139a105132150154157166114d114e166165164163108a171172160161151143126136136150179178180102107a 107b176176a176b176c176d131140d 140f 140e 140h 140g117117117117117170170131141108b 134138128130181182107a107b101b101c 101d104a124186185184183ill.595669M00p1Main view, Wash + Rinse for 44 inch machineFrom Ser. nr.: 227Doc. Nr.: 595669M00From Ser. nr.: 227Doc. Nr.: 595669M00From Ser. nr.: 227Doc. Nr.: 595669M00From Ser. nr.: 227Doc. Nr.: 595669M00ill. 595669M00p2Main view, Prewash for 22 inch moduleFrom Ser. nr.: 227Doc. Nr.: 595669M00From Ser. nr.: 227Doc. Nr.: 595669M00From Ser. nr.: 227Doc. Nr.: 595669M00From Ser. nr.: 227Doc. Nr.: 595669M00From Ser. nr.: 227Doc. Nr.: 595669M00From Ser. nr.: 227Doc. Nr.: 595669M00ill. 595669M00p4Prewash hydraulic circuit, Prewash for 22 inch moduleFrom Ser. nr.: 227Doc. Nr.: 595669M00From Ser. nr.: 227Doc. Nr.: 595669M00From Ser. nr.: 227Doc. Nr.: 595669M00From Ser. nr.: 227Doc. Nr.: 595669M00From Ser. nr.: 227Doc. Nr.: 595669M00From Ser. nr.: 227Doc. Nr.: 595669M00Electrical components, Wash + Rinse for 44 inch moduleFrom Ser. nr.: 227Doc. Nr.: 595669M00From Ser. nr.: 227Doc. Nr.: 595669M00From Ser. nr.: 227Doc. Nr.: 595669M00From Ser. nr.: 227Doc. Nr.: 595669M00Electrical components, Prewash for 22 inch moduleFrom Ser. nr.: 227Doc. Nr.: 595669M00From Ser. nr.: 227Doc. Nr.: 595669M00From Ser. nr.: 227Doc. Nr.: 595669M00。
qsep400说明书Qsep400,Qsep400Advance高通量核酸蛋白分析系统,无需人工制胶、染色、加样、拍照,操作简便,可自动计算片段大小,结果美观易判断,可直接检测分析96孔板整板样本,最快可达1min/4样本,大幅度提高检测效率,显著降低实验成本可替代普通凝胶电泳,且结果更清晰准确。
产品特点系统类型:4通道全自动上样:可分析单个样本不浪费试剂,100个样本高通量上样,检测速度快,还可升级多板位模块,满足更高通量需求上样形式:直接兼容0.2mL离心管、8联管、12联管、96孔板等通量灵活:可单次分析单个样品,也可96个样品整板上样,无浪费抛弃式卡夹:无需制胶、灌胶,每套卡夹可分析400-1200个样品(DNA、RNA和Protein) 快速分析:可达1分钟内/4样品高灵敏度:1pg/uL高分辨率:最佳可达1-4bp(500bp以内)定量范围:DNA<50ng/uL,RNA<500ng/ul分离范围:15bp-50kb,可检测大于50kb的片段,最大可达165kb结果呈现:数字数据,凝胶成像图,毛细管电泳图软件分析:同时进行定性及定量分析,界面友好,操作人性化样品需求和消耗:最低样品需求体积1uL,上样体积小于0.1pL低成本:市场上极为经济的仪器与耗材Qsep400系列规格荧光检测连接方式:USBLED激发光源电源:100-240V便携式空气压缩机重量:26KG电压:1-15kv 尺寸:54x40x36cm传统凝胶电泳的实验流程Qsep400系列检测一步到位(PCR产物直接上样)Qsep400系列相对传统凝胶的优势全自动完成多步工作:无需配胶、倒胶、点样、跑胶、拍照;无需定时观测,安全无毒自动分析记录:无需人工计算浓度大小快速分析:1-5分钟完成原先近1小时的工作灵敏度和分辨率:1pg/uL,1-4bp(500bp以内)节约样本:仅消耗0.1L样本节约耗材用量:无需每次实验添加DNAladder,并节省大量手套、枪头和PCR管结果美观直接:多种结果呈现形式,美观直接,不会出现“边缘效应"应用小结应用领域应用实验遗传学研究蛋白分析STR/SSR微卫星分型DNA指纹图谱分析核酸蛋白互作AFLP/RFLP病原微生物检测或分型常规PCR产物检测高分辨率基因分型转基因动植物检测Genomic DNA质控高分辨率多重PCR分析食品安全分析NGS建库质控质粒DNA酶切,构造及纯度分析农渔业养殖ct/cf DNA质控合成引物(primer)分析各种疾病筛查,分子诊断总RNA、mRNA、片段化RNA、micro-RNA质控Qsep 400系列高分辨率结果1.8%琼指糖凝胶高分辨率:清楚分辨4碱基差异的238bp和242bp条带pBR322-Mspl digestQsep400系列的分辨率可高达1%。
( Blank)About this manualThis manual applies to the Flexo Processor305DW/405DW/505DW/505DW XP.Always read the separate Safety Instruction Manual part No21741before operating the equipment.This manual is published by:Glunz& Jensen A/SLindholm Havnevej295800NyborgDenmarkPhone:+4557688181E-mail:*******************Internet:Copyright©January,2019by Glunz& Jensen A/SThe equipmentUnintended use of the equipmentGlunz&Jensen does not take any responsibility for any damage or accidents caused by unintended use of the equipment.It is absolutely prohibited to make any modifications,electrical or mechanical,of the equipment.If however this prohibition is disregarded,Glunz&Jensen's warranty will no longer apply.Intended use of the equipmentDevelopment and/or processing of flexographic plates as specified in Technical Specifications in the Service Manual.This equipment is a part of a full range dedicated for the treatment of flexographic printing plates.This range includes exposure,processor,dryer and light finisher.InstallationWARNING:The equipment must be installed in restricted access locations only.•Never install the equipment in explosive environments.•It is the responsibility of the owner and operator(s)of the equipment that the installation is made in accordance with local regulations,and by engineers authorized to carry out electrical,compressed air and HVAC installations.•The manufacturer cannot be held responsible for any damage caused by incorrect installation of the equipment.•Installation,service and repair must be performed only by service technicians who are trained in servicing the equipment.The installation procedure is described in the chapter'Installation'in the Service Manual.Service assistanceIf help is needed to correct any problem with the equipment,please contact your local supplier.•Turn on the main switch located at the front of the machine (right side).•The unit isnow displaying the standby screen.•To switch on the unit press "ON/OFF"button located below the control panel of the unit.•Then twodifferent screenscan be displayed.The processor is running an automatic cleaning cycle at the switch on.This screen disappears as soon as the cleaning cycle is finished.To cancel the cleaning cycle at the switch on press the "PERFORMING CLEANING CYCLE.PRESS TO STOP."button and confirm.The processor has been stopped with at least one plate in process.Press the "RESET"button and confirm to reset all ongoing cycles.Press the "RESTART"button and confirm to restart the processor at the same status as at the power off.This gives the possibility to continue the process of aplate remaining in the unit.Password FunctionThe buttonDescriptionto exit this screen and to return to the main screen. to switch to the next page.Plate settingsIt is possible to store25plates(channels0-24)with their washout speed and time(depending on the model).•By pressing the button following plate parameters screen is displayed(this button is available on the main screen as well as on the plate selection screen).305DW/405DW/505DW505DW XP These models can run only incremental mode.This model can run both incremental and batchmode.By running incremental mode it is used thewashout speed and by running batch mode it isused the washout time.By pressing"INC"button it can be chosenincremental or batch mode.•For each stored channel it is possible to modify the name of the plate as well as the dedicated parameters.•It is possible to scroll up or down the channels by pressing"+"or"–".•When the required channel is displayed,press the"PLATE TYPE:"field to change the plate name or one of the dedicated parameters.•Then an alphanumeric keyboard or a numeric keyboard will appear.Alphanumeric keyboard Numeric KeyboardNOTE:Always confirm the input by pressing"ENT"button,after typing in a new value.Not doing this may result in corrupted values memorization.305DW/405DW/505DW505DW XPTo select the plate to process,scroll up or down until required plate name is displayed.Press required plate name to highlight it.Then it is possible to check the plate parameters on the right side of theselected.theStarting washout cycle•Check that all plate parameters are correct.•Open the entrance cover.•Place the transport bar on the entrance table and ensure that it is well engaged in the locking devices located on each side(two"OK"signs on the screen).•Fix the plate on the middle of the transport bar to allow the plate length sensor(located in the middle of the entrance section)to detect the plate properly.•Close the entrance cover.•Press the"START"button to start the process cycle.This button is then flashing green till the plate is completely entered in the processor.Processing plate after plateIt is possible to run several plates in the same time in the processor if the washout speeds are the same.In this case,place the plate on the transport bar on the entrance and press the"START"button.The processor will automatically feed the plate in as soon as possible.If the washout speed of the plates is different,place the plate on the transport bar on the entrance and press the"START"button.The processor will automatically feed the plate in as soon as the previous plate is out of the cleaning section.NOTE:The processor can process a maximum of3plates in the same time.NOTE:The sensor which measure the length of the plate is located in the middle of the processor.Make sure that plate is placed in front of this sensor.AlarmsTwo different kinds of alarm can appear on the screen:•Process alarm –with flashing the sign and intermittent sound.•Service alarm –with flashing thesign.To identify which process alarm is on,press the flashing sign to display the dynamic synoptic screen.A graphic alarm sign indicates the type of alarm (please refer to following examples):If problem occurs on a circuit breaker for the pumps or motors,the process alarm sign is flashing on the motor or the pump.If levels problem occurs on the different solvent tanks,the level sign is flashing and indicating a problem in a tank (low or high level).NOTE:It is possible to stop the buzzer by pressing the buzzer icon.The buzzer will automatically restart if another alarm occurs.cycle performs the cleaning of all the brushes usingCleaning the digital sectionWARNING:Please wear appropriate protective clothing(gloves,glasses,and safety shoes)and ensure the adequate ventilation.•Open the washout covers.•Remove the hose with the spray box:Push thesilicone hose into the fitting and the edge of thefitting backwards simultaneously and then pull thehose out(the same as for air connection).•Remove the solvent distribution tray.•Loosen the screws on both sides of the twosplash guards.•Lift up and remove the splash guards.•For better access remove also the input plate.•Remove brushes according to"Cleaning the washout section"on page 21.•Remove two spring-loaded screws on both sides.•Now the grid can be removed to the side.•Clean the digital section.•Place the four springs and their support plates tothe original position.•Reinstall the grid by reusing the four screws so that the transition on both sides of the grid is smooth.Level difference must be less than1–2mm.NOTE:Correct washout of the LAMS layer(black digital plate layer)must be verified afteradjustment.•When the cleaning is finished,reinstall all removed parts in reverse order.Make sure the brushes are installed correctly and secured with the retainer ring.Drain the main washout tank:-Switch to the Manual functions screen.。