FLUKE 287 289 入门指南
- 格式:pdf
- 大小:649.00 KB
- 文档页数:20


福禄克常⽤型号万⽤表fluke15B+179,187,28-2,87vmax,fluke289
简单评测⼀下这常⽤的⼏款表fluke15B+,3位半,数字万⽤表。交流电流,电压, 直流电流,电压,电阻,电容,通断,⼆极管,⾃动保持,背光灯,⾃动/⼿动量程,⾃动休眠关机
fluke179,3位半,真有效值,增加功能(相对于15B+),频率测量,温度测量,最⼤值/最⼩值
fluke87V, 28-2, 87v max,这3个表基本功能⼀样,增加的有(相对于179),插⼊错表笔提⽰,低通滤波器,数据保存,占空⽐,电导,可切换4位半精度,测失真波。3个表的按键⼀样,区别是
87V是 IP30防护,3⽶跌落,400⼩时电池。
28-2和87v max 是IP67防护,4⽶跌落,800⼩时电池。
28-2和87v max 基本⼀样。
fluke187,189 经典的表,不多说。
fluke287,289 ,功能最全,体积⼤,操作复杂点,开机时间久8秒,太耗电,包括以上的所有功能。还多了趋势图,数据记录功能很强⼤。
总结,福禄克最适合的表还是 179, 187/189, 87V 这3种。15B+功能太少,⼜贵。
28-2和87v max 和 87v功能⼀样,就是更厚实,省点,当然贵多了。
287和 289 功能太多,⼤部分⽤不上,体积⼤,耗电,操作也⿇烦点。
PN 4271782 August 2012 © 2012 Fluke Corporation. All rights reserved. All product names are trademarks of their respective companies. 287/289
True-rms Digital Multimeters
Safety Information
Go to to register your product and find more information. A Warning identifies conditions and procedures that are dangerous to the user. Warning To prevent possible electrical shock, fire, or personal injury: • Read “Safety Information” before using this Meter. • Use this Meter only as specified in this manual or the protection provided by the Meter might be impaired. • Do not use the Meter if it is damaged. Before you use the Meter, inspect the case. Look for cracks or missing plastic. Pay particular attention to the insulation surrounding the connectors. • Make sure the battery door is closed and latched before operating the Meter. • Remove test leads from the Meter before opening the battery door. • Inspect the test leads for damaged insulation or exposed metal. Check the test leads for continuity. Replace damaged test leads before you use the Meter. • Do not apply more than the rated voltage, as marked on the Meter, between the terminals or between any terminal and earth ground. • Never operate the Meter with the cover removed or the case open. • Use caution when working with voltages above 30 V ac rms, 42 V ac peak, or 60 V dc. These voltages pose a shock hazard. • Use only the replacement fuses specified by the manual. • Use the proper terminals, function, and range for measurements. • Avoid working alone. • When measuring current, turn off circuit power before connecting the Meter in the circuit. Remember to place the Meter in series with the circuit. • When making electrical connections, connect the common test lead before connecting the live test lead; when disconnecting, disconnect the live test lead before disconnecting the common test lead. • Do not use the Meter if it operates abnormally. Protection may be impaired. When in doubt, have the Meter serviced. • Do not operate the Meter around explosive gas, vapor, or dust. • Use only 1.5 V AA batteries, properly installed in the Meter case, to power the Meter. • When servicing the Meter, use only specified replacement parts. • When using probes, keep fingers behind the finger guards on the probes. • Do not use the Low Pass Filter option to verify the presence of hazardous voltages. Voltages greater than what is indicated may be present. First, make a voltage measurement without the filter to detect the possible presence of hazardous voltage. Then select the filter function. • Only use test leads that have the same voltage, category, and amperage ratings as the meter and that have been approved by a safety agency. • Use proper protective equipment, as required by local or national authorities when working in hazardous areas. • Comply with local and national safety requirements when working in hazardous locations. • To avoid circuit damage and possibly blowing the Meter’s current fuse, do not place the probes across (in parallel with) a powered circuit when a lead is plugged into a current terminal. This causes a short circuit because the resistance through the Meter's current terminals is very low. • To avoid possible electric shock or personal injury, do not use the Low Pass Filter option to verify the presence of hazardous voltages. Voltages greater than what is indicated may be present. First, make a voltage measurement without the filter to detect the possible presence of hazardous voltage. Then select the filter function. • To avoid the potential for fire or electric shock, do not connect the thermocouple to electrically live circuits. • To avoid damage to the Meter and possible injury, never attempt an in-circuit current measurement where the open-circuit potential to earth is greater than 1000 V. • To avoid electrical shock or personal injury, repairs or servicing not covered in this manual should be performed only by qualified personnel as described in the 287/289 Service Information. • To avoid electrical shock or personal injury, remove the test leads and any input signals before replacing the battery or fuses. To prevent damage or injury, install only Fluke specified replacement fuses with the amperage, voltage, and speed ratings shown in the User’s Manual. • Do not exceed the Measurement Category (CAT) rating of the lowest rated individual component of a Product, probe, or accessory. • Do not use the TL175 or TP175 test probes in CAT III or CAT IV environments without the probe tip fully extended and correct category rating visible in the window. • When the TL175 is used with instruments or other accessories, the lowest category rating of the combination applies. One exception is when the probe is used with the AC172 or AC175.
PN 4245967 (Simplified Chinese) August 2010 Rev. 1, 7/11 © 2010-2011 Fluke Corporation. Specifications are subject to change without notice.
All rights reserved. Printed in China
2AC
VoltAlert
说明书
首先阅读:安全须知 WX 警告 为避免可能发生的触电或人身伤害: • 如果未依照制造商的指示使用本测试仪,则本测试仪提供的保护功能可能会受到影响。 • 使用前后,在本产品的额定交流电压量程内,在已知带电的电源上进行测试,以确保产品处于良好的工作状态。 • 在使用本测试仪时,即使尖端没有发光,仍然可能会有电压存在。本测试仪指示了在有电源(市电电源)电压产生足够强度静电场时的有效电压。如果场强很低,则本测试仪可能不提供现场电压的指示。如果有电压存在而本测试仪无法检测到,则会发生 无指示的情况。导致此类状况产生的因素包括但不限于: • 屏蔽的电线/电缆 • 绝缘层的厚度和类型 • 到电压源的距离 • 完全绝缘、无法有效接地的使用者 • 凹处插座中的插孔/插座设计的差异 • 本测试仪和电池的状况 • 如果测试仪已经损坏,或者测试仪无法正常工作,请勿使用。使用前请特别检查探头尖端是否有破裂或断头现象。若有疑问,请将测试仪送修。 • 请勿施加超过测试仪上标记的额定电压。 • 测量交流 30 伏以上的电压时须特别小心,避免发生触电。 • 遵守当地和国家的安全规范。 • 依照当地或国家主管当局的规定使用适当的保护设备。 表 1. 符号 T 双重绝缘
X 危险电压:有触电危险 W 有危险。重要信息。请见说明书。 ) 符合加拿大和美国的相关标准。 P 符合相关欧盟指令 符合澳大利亚的相关标准 ~ 请勿将本产品作为未分类的城市废弃物处理。请访问 Fluke 网站了解回收信息。 CAT IV 设备的设计可以使其免受初级供应电压水平所产生的瞬变的影响。(即:电表或者高架/地下市电供应)。 仅供有操作能力的人员使用 使用本仪器的任何人均应了解和受训过测量电压(尤其是工业领域中的电压)所涉及的风险,以及采取安全防范措施和测量前后对仪器进行测试的重要性,以确保仪器处于良好的工作状态。 2AC 说明书 第 2 页
-
. z. fluke测试仪
配置手册
神州数码系统集成服务**
2013-10
目录
1.界面功能介绍1
2.主机与备机查看1
3.IP地址配置2
4.对端口进行吞吐量的测试2
5.报告文件的查看3
fluke测试仪主要是针对端口速率及流量的测试,下面将对怎么配置使用进行简单说明。
1.界面功能介绍
包括有连接状态,端口速率等信息如下图所示:
2.主机与备机查看
主机与备机之间的决定是根据设置的密钥代码所决定的,如下图为主机,选项会有LAN选件、RFC 2544/ITO选件。
下图为备机:选项只有LAN选件。 -
. z. 3.IP地址配置
点击100MB的对话框后,再选择TCP/IP选项。
在右边的对话框会出现IP地址,输入对应的IP与掩码后,点OK,如图所示:
提示:输入的键盘点击最下面的“键盘”图案,即可输入文字。
4.对端口进行吞吐量的测试
1. 点击标有蓝色按钮“主页”的图案,再点击ITO测试旁边的+
2. 选择吞吐量测试
3. 点击标有蓝色按钮“详细信息”的选项
远程设备选择对端的备机,内容:全部是0,超时:10,大小里面包含了64K,128K,512K,1024K,1280K,1518K,-
. z. Sweep。一般选择Sweep,代表全部。
速率和持续时间上,就选择针对要测试的商品类型,如图以百兆商品为例作为测试,时间设置一般为60秒,再点开始就会进行测试。
下图为修改吞吐量的配置,点击配置“按钮”进行修改,修改后可以继续进行测试。测试完后点击报告,就可以把报告定义一个文件名及存储到CF卡上,然后把机器关上,把CF卡取出,用读卡器读取拷贝到电脑上进行分析。
5.报告文件的查看
点击左上角键盘按钮旁边的图案,会弹出标有报告的选项,点击就会打开到CF卡里面的测试报告文件。