G765-250•••••Technical dataFunctional dataValve Size 2.5" [65]Fluidchilled or hot water, up to 60% glycol Fluid Temp Range (water)32...350°F [0...176°C]Body Pressure Rating ANSI Class 250, up to 280 psi below 350°F Flow characteristic linearServicing repack/rebuild kits available Rangeability Sv 50:1Flow Pattern 3-way Mixing Leakage rateANSI Class III Controllable flow range stem up - open B – AB Cv 68 ANSI Class250Body pressure rating noteup to 280 psi below 350°F MaterialsValve body Cast iron - ASTM A126 Class B Valve plug bronzeStem seal NLP EPDM (no lip packing)SeatStainless steel AISI 316Pipe connection250 lb flanged Suitable actuatorsNon-Spring EVB(X)RVB(X)Electronic fail-safeAVKB(X)(2*GKB(X))Safety notesWARNING: This product can expose you to lead which is known to the State of California to cause cancer and reproductive harm. For more information go to The valve has been designed for use in stationary heating, ventilation and air-conditioning systems and must not be used outside the specified field of application, especially in aircraft or in any other airborne means of transport.Only authorised specialists may carry out installation. All applicable legal or institutional installation regulations must be complied during installation.The valve does not contain any parts that can be replaced or repaired by the user.When determining the flow rate characteristic of controlled devices, the recognised directives must be observed.Product featuresG765-250 Flow/Mounting detailsDimensionsDimensional drawingsEVB, EVX, RVB, RVXA B C D E F Number of Bolt Holes12.0" [304]9.6" [245]25.4" [646]18.3" [464] 3.7" [95] 3.7" [95]82*GMB, 2*GMX, 2*GKB, 2*GKXA B C D E F Number of Bolt Holes12.0" [304]9.6" [245]29.0" [736]21.8" [554] 3.7" [95] 5.3" [135]8AVKB, AVKXA B C D E F Number of Bolt Holes12.0" [304]9.6" [245]25.4" [646]18.3" [464] 3.7" [95] 3.7" [95]8AFB, AFXG765-250A B C D E F Number of Bolt Holes12.0" [304]9.6" [245]24.0" [610]16.9" [428] 3.7" [95] 5.3" [135]82*AFB, 2*AFXA B C D E F Number of Bolt Holes12.0" [304]9.6" [245]29.0" [736]21.8" [554] 3.7" [95] 5.3" [135]8RVB24-3•••••On/Off, Floating Point, Non-Spring Return, Linear, 24 VTechnical dataElectrical dataNominal voltageAC/DC 24 V Nominal voltage frequency 50/60 Hz Power consumption in operation 6 W Power consumption in rest position 1.5 WTransformer sizing 11 VA (class 2 power source)Electrical Connection 18 GA plenum cable, 3 ft [1 m], with 1/2" conduit connector, degree of protection NEMA 2 / IP54Overload Protection electronic throughout full stroke Electrical Protectionactuators are double insulated Functional dataActuating force motor 1010 lbf [4500 N]Input Impedance 100 kΩ (0.1 mA), 500 Ω, 1000 Ω (on/off)Position feedback U note No Feedback Direction of motion motor selectable with switchManual override 5 mm hex crank (3/16" Allen), supplied Stroke2" [50 mm]Running Time (Motor)90 s, constant, independent of load Running time motor note constant, independent of load Noise level, motor 65 dB(A)Position indicationMechanically, with pointer Safety dataDegree of protection IEC/EN IP54Degree of protection NEMA/UL NEMA 2 UL Enclosure Type 2Agency Listing cULus acc. to UL60730-1A/-2-14, CAN/CSAE60730-1:02, CE acc. to 2014/30/EU and 2014/35/EU Quality Standard ISO 9001Ambient temperature -22...122°F [-30...50°C]Storage temperature -40...176°F [-40...80°C]Ambient humidity max. 95% r.H., non-condensing Servicingmaintenance-free Weight Weight 9.02 lb [4.1 kg]MaterialsHousing materialDie cast aluminium and plastic casingSafety notesPVC W'Shld for GV w/UGLK (GM)Battery Back Up System for SY(7~10)-110120 to 24 VAC, 40 VA transformer.50% voltage divider kit (resistors with wires).PC Tool computer programming interface, serial port.RVB24-3 Electrical installationINSTALLATION NOTESActuators may be connected in parallel. Power consumption and input impedance must be observed.Actuators may also be powered by 24 VDC.Control signal may be pulsed from either the Hot (Source) or Common (Sink) 24 V line.For triac sink the common connection from the actuator must be connected to the hot connection of thecontroller. Contact closures A & B also can be triacs. A & B should both be closed for the triac source andopen for triac sink.Actuators with plenum cable do not have numbers; use color codes instead.Meets cULus requirements without the need of an electrical ground connection.Warning! Live Electrical Components!During installation, testing, servicing and troubleshooting of this product, it may be necessary to workwith live electrical components. Have a qualified licensed electrician or other individual who has beenproperly trained in handling live electrical components perform these tasks. Failure to follow all electricalsafety precautions when exposed to live electrical components could result in death or serious injury.On/Off Floating Point。
兰吉尔热表MBUS抄表数据格式说明:串口设置波特率300-4800,推荐设置:UH50、2WR6 :波特率2400,8位数据,偶校验,1位停止位F4:默认波特率300,可以更改为2400,更改方法见UH50.pdf抄表命令格式分两种,一种是一级地址抄表(地址为0~255);一种是二级地址抄表(地址为00000000~99999999),仪表在两种格式情况下回复的数据格式一致。
一、一级地址抄表一级地址抄表比较简洁,知道地址可以直接发送读表命令10 7B A CS 16其中A为一级地址的16进制形式,CS为7B+A的和(取后两位),二、二级地址抄表这里以二级地址为12345678 为例,完成一次抄表需要三个步骤:1、设备选择:68 0B 0B 68 53 FD 52 78 56 34 12 FF FF FF FF 16表回复:E52、读取命令:10 7B FD 78 16(可认为固定)表回复不同标准的mbus格式数据,已经发现不同厂家有不同的数据格式:兰吉尔:2WR5/UH50:254字节(长)或57字节(短),MBUS模块不短接为长格式,短接时为短格式,另外还有若干错误信息,格式详见pdf。
2WR6:206字节F4:150字节3、发送指令3为取消选择:10 40 FD 3D 16(可认为固定)。
三、数据格式2WR5/UH50:(这里仅提供一个示例数据,详细解析见各型号的PDF格式的说明文件)接收到长度为254字节的数据如下:(64103298)68 F8 F8 68 F8 字符长度(从表号第一位98开始)为248 08 00 72 变量长度结构(校验和从第五字节开始)98 32 10 64 表号:6410329825 4D 确认码02 精度等级2级04 Medium(介质):heat 0...4: Acc.to DIN EN 143405 10 00 00 数字签字:00 0009 74 04 刷新时间(s):04 (4秒)09 70 04 平均值以秒为单位的时间(s):04 (4秒)0C 06 06/07/0E/0F 热量单位(KWH,MWH/100,MJ GJ/100)00 00 00 00 当前累计热量(Kwh):00 00 00 000C 14 14/15 累计流量单位(M3 *1/100, M3 *1/10)00 00 00 00 当前累计流量00 00 00 00 000B 2E 2D/2E 功率单位(KW/10,KW)00 00 00 当前功率(KW):00 00 000B 3B 3B 瞬时流量单位(l/h)00 00 00 当前瞬时流量(M3/h): 00 00 000A 5B 进水温度单位(℃)32 00 当前进水温度:00 320A 5F 回水温度单位(℃)28 00 当前回水温度:00 280A 62 温差单位(℃/10)39 00 当前温差: 00 39 4C 14 14/15 累计流量(M3 *1/100。
浅谈关口计量点电量追补方法代燕杰1,彭静2,高玉领3,邹超41.山东电力研究院,山东省济南市二环南路500号,2500022.山东电力集团公司莱芜供电公司,山东省莱芜市鲁中西大街21号,2711003.山东电力超高压公司,山东省济南市经十路111号,2500214.山东电力集团公司济南供电公司,山东省济南市天桥区堤口路171号天桥供电部,250001 Discussion on the Compensation Method for Electric Energy of Gateway Metering PointDai Yanjie,Peng Jing,Gao Yuling,Zou ChaoShandong Electric Power Research Institute, Jinan 250002, ChinaABSTRACT:This paper analysis the abnormal reason of electric energy in gateway metering point of an electric power plant.. The methods of compensated for electric energy are summed up. . The processing procesure on-site is discussed combined with a power plant fault example.KEY WORDS: metering point;electric energy;compensation摘要:本文分析了电厂上网关口计量点的电量异常原因,总结了追补电量的方法,并结合发电厂故障实例讨论了现场追补电量的处理方法。
关键词:计量点;电量;追补0 引言计量点就是应安装计量装置的位置,分为电力客户计费点和关口计量点,电力客户计费点是指电网经营企业与电力客户间结算电费的电能计量点,关口计量点按其性质分为结算关口和考核关口,而结算关口电量直接关系到企业的经济效益,随着厂网分开以及电力市场的逐步形成,关口计量的地位举足轻重,在计量点处一般使用进口高质量的0.2S级多功能电能表。
ZD电表IEC1107规约说明参考文件 June, 20031.总体说明:1.1通讯规约:ZD电表通讯规约满足IEC1107标准。
1.2通讯模式:ZD电表采用IEC1107 模式C进行通讯。
1.3通讯过程说明:1.3.1按照IEC1107标准的规定,电表可以采用初始波特率为300Bd进行通讯。
1.3.2在收到电表型号信息后,采集装置需在200ms(20ms)~1500ms之间作出应答,确认波特率的选择;如果电表在1500ms内没有收到确认信息,则以300Bd 向采集装置发送计费数据。
说明:ZD 通讯单元的通讯波特率通常设定为初始300Bd, 最大9600Bd。
2.数据读取:2.1计费数据的读取(C模式,Data Readout):2.1.1在300Bd下,发“/?电表地址!CR LF”命令。
2.1.2电表应返回“/LGZx 电表信息 CR LF”,其中“x”代表电表通讯波特率。
0 – 300Bd, 1 – 600Bd, 2 – 1200Bd,3 – 2400Bd,4 – 4800Bd,5 – 9600Bd;2.1.3C模式下的“Data Read out”命令(其中“x”应与2.1.2中的“x”一致)。
2.1.4电表以“x”所代表的波特率向采集装置发送电表的计费数据,格式为“STX 数据!CR LF ETX BCC。
说明:计费数据的配置在电表订货时由用户确定。
在IEC读出量较多或IEC读出存储值个数较多时,通讯时间会比较长。
因此用户在订货时,根据需要选择合理的配置。
2.2负荷曲线的读取:2.2.1在300Bd下,发“/?电表地址!CR LF”命令。
2.2.2电表应返回“/LGZx 电表信息 CR LF”,其中“x”代表电表通讯波特率。
0 – 300Bd, 1 – 600Bd, 2 – 1200Bd,3 – 2400Bd,4 – 4800Bd,5 – 9600Bd;电表信息代表电表的型号和配置信息。
兰吉尔FFC电能表处理器用户手册1. 一般信息 (6)1.1参数设置(编程) (6)1.2电气安装 (6)1.3接口 (7)2技术参数 (9)2.1适用标准 (9)2.2输入电源 (9)2.3直流扩展输出电源(选项配置) (9)2.4环境参数 (9)2.5内部时钟 (10)2.6数据缓存区 (10)2.7服务接口 (10)2.8主站通讯接口 (10)2.9表计通讯接口 (11)2.10网络口 (13)2.11 缺省密码: (13)3关于报废处置 (13)4附图 (14)4.1机架式FFC安装结构图 (14)4.2挂式FFC安装结构图 (15)4.3电表CS接口连接示意图(仅供参考) (16)4.4电表RS485接口连接示意图(仅供参考) (16)5操作 (1)5.1 发光管显示 (1)5.2 液晶显示 (1)5.2.1 键盘与显示器规格 (1)5.2.2 日常操作与显示 (1)5.2.3 通用出错操作与显示 (2)5.2.4 菜单操作与显示 (2)6其他说明 (6)7功能 (6)7.1密码保护功能 (6)7.2 主菜单功能 (6)7.4参数功能 (7)7.4.1 在线参数查询 (7)7.4.2 离线参数查询 (15)7.4.3 参数修改 (15)7.4.4 离线修改 (15)7.4.5 参数下载 (24)7.5时间功能 (25)7.5.1 时间设置 (25)7.5.2 分钟同步 (26)7.6 网络功能 (26)7.6.1 网络参数查看 (27)7.6.2 网络参数修改 (27)7.7系统诊断功能 (28)7.7.1负荷曲线查询 (28)7.7.2事件查询 (30)7.7.3RTU状态查询 (31)7.7.4通讯状态查询 (31)7.7.5系统自检 (31)7.8系统工具功能 (32)7.8.1系统定义功能 (32)7.8.2密码修改 (33)7.8.3语言转换 (34)7.8.4版本信息 (34)7.9关闭FFC (34)8附录A 名词解释 (35)8.1On Line Param在线参数 (35)8.2Off Line Param离线参数 (35)9 规约的附加说明 (36)SCTM (36)IEC102 (36)DF102 (37)DL719网络规约 (37)ZB446 (38)ZB647 (38)DGCOM (39)ALPHA (39)AL-LP (40)ALPHA(A1R) (41)ALPHA(A1R-1) (41)DLT645 (42)ZD446 (43)EDMI3 & EDMI6 (45)ED6LP (46)QUAD4 (47)QUAD4-N (48)VDEW (49)WEISHENG (49)STOM (50)1. 一般信息谢谢您使用兰吉尔表计公司的FFC产品。
A1800电能表客户简易手册1,电表基本标识:1,电压指示指示某相电压存在。
例如,如1、2和3均有显示,则表示所有三相电压都有,而若1、2、3均闪烁,则表示所有三相电均没有电压。
某相电压指示闪烁表示该相没有电压或失压。
2,显示项编号该显示项编号可有七位数字组成。
可以通过Metercat软件指定每个显示项的编号。
3, LCD左上方的四个箭头用于指示被测电能所处象限,共有四个,分别指示与有功、无功电能有关的四个象限。
2,电表常见故障码含义及简单处理办法:故障码包括错误代码,告警代码,通讯代码Ⅰ, 错误代码说明:A1800电表是用一个组代码和一个数字代码在液晶显示屏上指示错误代码.组代码使错误更容易在液晶器上被识别.数字代码指示出现的特定情况.举例见图:其中组代码为E1,数字代码为000100.具体组E1代码类别和数字代码含义如下:情况代码转存错误0 0 0 0 0 1 停电中,电表的易失RAM中保存的数据的校验和出错.晶振错误0 0 0 0 1 0 指示一个与晶振有关的错误.CRC 错误0 0 0 1 0 0 电表编程时可能出现的错误,使用ELSTER软件可修复. 内部通讯错误0 0 1 0 0 0 电表出现了一个内部通讯错误.EEPROM 访问错误0 1 0 0 0 0 电表出现了非易失EEPROM的错误.一般配置错误 1 0 0 0 0 0 电表配置或程序问题,用ELSTER软件重新编程可修复. 组E2代码类别和数字代码含义如下:情况代码安全配置错误0 0 0 0 0 2 该代码指示电表安全配置中出现的一个错误.密码CRC 错误0 0 0 0 2 0 表示在电表的ANSI C12.21密码配置中出现CRE差错.加密钥匙CRC 差错0 0 0 2 0 0 表示在电表的ANSI C12.19加密钥匙配置中出现CRE错. ROM 故障错误0 2 0 0 0 0 电表固件写入不完整.用ELSTER固件升级软件可修复. 断电数据保存错误 2 0 0 0 0 0 一次断电期间,非易失EEPROM中保存的数据可能无效. 组E3代码类别和数字代码含义如下:情况代码时钟错误0 3 0 0 0 0 电表计时能力出现错误,更换电池,用ELSTER软件编程. 告警锁定显示屏 3 0 0 0 0 0 表明一个或多个告警代码已经锁定显示屏.Ⅱ,告警代码告警代码用于指示那些还没有影响到记费数据完整性的有关情况。
兰吉尔电能量采集器FFC技术规范兰吉尔电表处理器FFC,是一个专用的电能量采集远方终端设备。
FFC电表处理器除采集数据外,还可对数据进行必要的加工处理,具有存贮和显示功能,并可将数据按一定规约传送到主站系统。
FFC是“FAG For China ”的缩写。
FAG电表处理器是兰吉尔表计公司在全球广泛使用的著名处理器。
为了适应中国市场的特殊需要,在借鉴原有FAG等处理器的优秀特性基础上,专门为中国市场开发了FFC电表处理器,其产品性能追求FAG的高标准。
FFC真正解决了多种不同规约的电表(包括第三方电表)同时接入同一处理器的问题,因此,该处理器将更加适应中国用户的需求。
标准及基本硬件结构:标准和质量证书FFC满足IEC 1000及IEC 61000电磁兼容、高温,气候环境影响、机械性能、安全性能等相关标准, 通过了电力工业电力设备及仪表质量检验测试中心的型式试验, 检验报告证书编号为: (配用电) 检字2004 第039号; 并获得了集中抄表系统产品型号注册登记证, 注册编号: 2004020-I产品所遵循的检测标准:1, DL/T743-2001 《电能量远方终端》2, DL/T698-1999 《低压电力用户抄表系统技术条件》环境参数1, 运行温度: -10 o C~+55 o C2, 运行湿度: <=90%无凝结3, 振动: IEC68-2-64, 机械强度: IEC68-2-27外形尺寸1, 机架式FFC2000U1.1:19”2U标准工业机箱1.2:448(宽)x87(高)x338(深)mm1.3:重量约为8Kg2, 壁挂式FFC2000C2.1:240(宽)x340(高)x103.5(深)mm2.2:重量约为4.6Kg外部接线端子1, 电源端子、表计接口端子、主站接口端子均采用进口PHENIX端子2, 表计接口端子及主站接口端子为标准的4芯端子,通用性好外部LED指示灯1, 装置运行灯,灯亮时表明装置正在运行2, 电源指示灯2个,交流供电时AC灯亮;直流供电时DC灯亮,交/直流同时供电时,AC灯、DC灯同时亮3, 表计口通讯指示灯8个,灯闪烁时表明正在进行交换数据4, 主站口通讯指示灯2个,灯闪烁时表明正在进行交换数据内部时钟准确度: +/-1秒/天服务口,亦即当地维护接口:FFC的服务口位于前面板上(LCD模块), 参数如下:1, 传输标准:EIA RS232 C/V.242, 波特率:56Kb/s3, 连接头:RJ11型连接器4, 最大电缆长度:15米5, 传输方式:异步FFC完全是按模块化思路去设计的一种电力设备,其外观则是一个整体,功能模块全部选用工业级的产品,并装配在机箱内部。