寒冷 B 区的高性能节能建筑能耗计算分析厉盼盼 朱峰磊 李红 林林中国建筑科学研究院有限公司摘 要: 针对寒冷B 区的5个典型城市, 研究分析了气象文件、 系统性热桥、 高性能窗等对建筑能耗的影响。
提出 对气象文件中的温度、 太阳辐射分析, 可以确定供暖空调起始日期及对建筑能耗影响的比例。
利用模拟计算的方法, 外墙外保温的单个锚栓对系统传热系数增加值为小于等于0.002W/(m 2· K)。
对高性能窗的性能进行研究, 得 出窗户的气密性及玻璃层数的配置, 直接影响建筑能耗趋势, 且采用活动外遮阳的总能耗比固定遮阳的降低 9% 左右。
关键词: 寒冷B 区 高性能建筑 能耗计算 技术体系Calculation and Analysis of Energy Consumption of HighPerformance EnergySaving Buildings in Cold Zone BLI Panpan,ZHU Fenglei,LI Hong,LIN Lin China Academy of Building ResearchAbstract: The energy consumption influence of weather data,systematic thermal bridge and highperformance windows on five typical cities in cold zone B was studied and analyzed.Based on the analysis of temperature and solar radiation in weather documents,the starting date of heating and air conditioning and the proportion of influence on building energy consumption can be ing the method of dynamic simulation calculation,the added value ofthe system heat transfer coefficient of a single anchor bolt for external insulation is less than or equal to 0.002W/(m 2 · K).The performance of highperformance windows were studied,and it was concluded that the air tightness of the windows and the number panes of glass,directly affect the trend of building energy consumption,and the total energy consumption of active external shading is about 9%lower than that of fixed shading.This paper also analyzes the calculation process and ideas of fresh air and exhaust heat recovery technology,which is useful to the reasonable selection of exhaust heat recovery equipment and calculation of heat recovery amount.Keywords:cold zone B,highperformance buildings,energy calculation,technology system收稿日期: 2019226作者简介: 厉盼盼 (1989~), 女, 硕士; 上海市打浦路 88号19楼 (200023); Email:**********************我国的建筑节能工作伴随着改革开放政策 40 年 来稳步推进, 各地的节能技术路线从原来的无围护结构保温发展到现在的满足国家或者地方节能设计标 准要求的节能建筑。
北辰区红星国际广场A2地块项目四步节能施工方案中建五局第三建设有限公司红星国际广场A2地块项目一、编制依据二、工程概况本工程场地位于天津市北辰区京津公路与龙门东道交口处,建筑面积23.06万m2,由2栋高层办公楼、6栋高层住宅楼和裙房商业楼以及配套设施组成,建筑合理使用年限50年.建筑节能做法概述:三、外墙保温施工(一)、主要材料性能指标锚栓抗拉承载力标准值满足下表要求岩棉板性能(二)、外墙保温施工(1)、外墙施工前的准备工作1、施工材料石墨聚苯板板粘结剂及抹面胶浆;网格布、热镀锌电焊网片、接锚固件、石墨聚苯板、岩棉板、岩棉带等。
2、在正式施工前做好进场材料的复试工作,应复试的内容如下:石墨聚苯板:表观密度、抗压强度、导热系数、燃烧性能、尺寸稳定性、吸水率、水蒸气透过系数、燃烧性能等。
无机保温砂浆:干表观密度、湿表观密度、导热系数、抗压强度、28天软化系数、燃烧性能、堆积密度、凝结时间、水蒸气透过系数。
胶粘剂:拉伸粘接强度、可操作时间抹面胶浆:拉伸粘接强度、柔韧性、可操作时间抗裂砂浆:可使用时间、拉伸粘接强度、浸水拉伸粘结、强度压折比界面剂:压剪粘结强度锚栓:单个锚栓抗拉承载力热镀锌电焊网:耐腐蚀能力网格布:耐碱断裂强力4.施工工具①壁纸刀、螺丝刀、收锯、强制式砂浆搅拌机、手提搅拌器、垂直运输机械、手推车、射钉枪、扫帚、钢丝刷、棕刷、冲击钻等。
②常用抹灰工具及抹灰专用检测工具:经纬仪、抹子、阴阳角抹子、水桶、剪刀、滚刷、铁锹、手锤、錾子、托线板、2m靠尺、塞尺、钢尺、直尺、卷尺、墨斗、卷尺、粗砂纸。
5.施工准备5.1.与施工有关的人员,施工前必须认真阅览施工图纸,并与施工现场进行对比,及时检查现场和图纸变更的情况。
5.2.落实施工材料及施工工具存放在、施工人员食宿安排等相关事宜。
5.3.检查垂直运输工具、脚手架,不得有任何安全隐患。
5.4.检查施工用水、电的情况.6.施工条件6.1。
墙面应清理干净,清洗油渍,清扫浮灰等。
基于BIM技术的居住建筑节能体形系数变化规律的研究摘要:在《天津市居住建筑节能设计标准》(五步节能)编制过程中,深入研究了体形系数与建筑层数、层高、耗热量等节能参数之间的数学函数关系,指导方案选型,并调整了原规范中不合理的要求,使得新规范的标准更能客观反映实际情况。
关键词:体形系数;层数;耗热量建筑能耗占社会总能耗的比重高达40%左右,降低建筑能耗对节能减排、保持可持续发展具有非常重要的意义。
在建筑能耗中,大约20% ~ 50% 由外围护结构传热所消耗。
建筑节能的主要措施是增强外围护结构的保温隔热性能,即增大其总传热阻。
外围护结构主要指建筑的外墙、屋顶和门窗,地面往往可忽略不计。
在工程实践中,建筑师进行节能设计主要是靠增大建筑物外墙、屋顶和门窗的传热阻,来实现特定的节能目标。
但建筑物的节能措施除了增大外围护结构的传热阻外,减小体形系数也是一个非常有效的手段,而很多建筑师对建筑的体形系数并不是十分重视。
一栋建筑物在特定条件下所蕴含的能量是与其内部空间大小成正比的,即与其体积成正比。
而建筑物热损失的大小是与其与外部空间的接触面大小成正比的,即与其外表面积成正比。
假若某建筑具有较大的体积,却有较小的外表面积,即体形系数小,则此建筑单位表面积的耗能量较小,其内部温度波动受外界影响亦较小,该建筑就形态上来说有着良好的保温隔热性能。
反之,若体形系数大,则建筑内部温度波动受外界影响较大,该建筑的保温隔热性能则不好。
这正是体形系数的核心含义,它反映了建筑物抵御外部热环境变化的能力。
节能设计时应尽量争取较小的体形系数,以取得更好的节能效果。
体形系数是单位建筑体积占用的外表面积,它反映了一栋建筑体形的复杂程度和围护结构散热面积的多少,体形系数越大,则体形越复杂,其围护结构散热面积就越大,建筑物围护结构传热耗热量就越大,因此建筑体形系数是影响建筑物耗热量指标的重要因素之一,是居住建筑节能设计一个重要指标。
我们日常设计工作中接触到的普通住宅楼最普遍的情况为用一个标准层批量复制,故各层的外形轮廓统一,层面积一致,周长一致,层高一致,体形系数为表面积与体积之比,可进一步表示为如下公式:S=F/V=(S0+C•H•N)/(S0•H•N)=1/(H•N)+C/S0(式1)式中:S—体形系数(m-1),F—表面积(㎡),V-体积(m³),S0—层面积(㎡),C-周长(m),N-层数,H-层高(m),当建筑方案基本确定时,楼体的周长、层面积、层高为定值,自变量仅为层数,体形系数与层数的关系呈反比例型函数的非线性变化规律,层数越多,体形系数越小我们可选取合适的层数以减小体形系数。
严寒C区新建居住建筑节能标准对比浅析摘要:为落实建筑节能工作,我国逐步提高建筑节能设计标准的要求[1]。
目前,我国严寒和寒冷地区新建居住建筑普遍执行65%节能标准,仅有北京、天津、唐山、保定、乌鲁木齐等少数城市已执行75%节能标准。
与我国北方地区有着相似气候条件的发达国家多数已执行低能耗建筑标准,我国北方地区尤其是严寒地区节能潜力巨大。
本文着重对比分析了《严寒C区居住建筑节能设计标准》与《严寒和寒冷地区居住建筑节能设计标准实施细则》在能耗、技术指标、成本等方面的差异,以期为全国严寒C区新建居住建筑执行75%节能标准提供借鉴与指导。
关键词:严寒C区;新建;居住建筑;节能;对比Comparison analyses of new residential building energy saving standards in cold area C GE Li man(The city construction committee of Urumqi, Xin jiang, urumqi,830092)Abstract: In order to implement the building energy saving work, the country gradually raised the requirement of the design standard of building energy efficiency [1]. At present, the severe cold and cold areas generally perform 65% new residential building energy saving standards, only Beijing, Tianjin, Tangshan, Baoding and Urumqi has performed 75% energy saving standards. And in north China region with similar climate conditions of most developed countries has been the standard of low energy consumption building, energy saving potential is tremendous especially in cold regionin north China. This paper focuses on analysis of the differences between" residential building energy saving design standard in cold C area " and " implementing rules forthe residential building energy efficiency design standards in cold and colder areas " in terms of energy consumption, technical index and cost. So as to provide reference and guidance for perform 75% new residential building energy saving standards in coldarea C.Key words: cold area C new residential building energy saving contrast 引言欧洲的节能建筑从70年代开始,经过了40多年的发展取得了不少经验和成绩。
龙源期刊网
四步节能
作者:
来源:《中国建筑防水·悦居》2016年第03期
为了贯彻国家节约能源的政策,扭转我国严寒和寒冷地区居住建筑采暖能耗大、热环境质量差的状况,我国政府对居住建筑节能减排提出了明确要求。
我国建筑节能是以1980~1981
年的建筑能耗为基础,按每步在上一阶段的基础上提高能效30%为一个阶段。
“一步节能”,是民用建筑节能设计标准的第一阶段,于1986年8月1日起实施。
所谓“一步节能”,即节能30%,是指在当地1980~1981年住宅通用设计能耗水平的基础上节约30%。
“二步节能”,是民用建筑节能设计标准的第二阶段。
我国于1996年7月1日起实施“二步节能”,所谓“二步节能”是指在当地1980~1981年住宅通用设计能耗水平的基础上节能50%。
随着全国建筑节能要求的不断提高,建筑节能技术的快速发展,目前我国住宅和公共建筑普遍执行的是节能65%的标准,这就是我们常说的“三步节能”。
而目前,北京、天津、新疆等地区在居住建筑方面已经开始执行75%的更高的节能标准,即为“四步节能”。
北京市供热信息统计报表制度(2018-2019年和2019-2020年采暖季)北京市城市管理委员会2018年3月本报表制度根据国家与本市有关统计法律法规的相关规定制定《中华人民共和国统计法》第七条规定:国家机关、企业事业单位和其他组织以及个体工商户和个人等统计调查对象,必须依照本法和国家有关规定,真实、准确、完整、及时地提供统计调查所需的资料,不得提供不真实或者不完整的统计资料,不得迟报、拒报统计资料。
《中华人民共和国统计法》第九条规定:统计机构和统计人员对在统计工作中知悉的国家秘密、商业秘密和个人信息,应当予以保密。
《北京市统计条例》第二条规定:本条例适用于本市各级人民政府及其统计机构和有关部门组织实施的统计活动。
《北京市统计条例》第十八条规定:企业事业单位和其他组织等统计调查对象应当加强对统计工作的管理,明确相关人员负责统计事项。
本制度由北京市城市管理委员会负责解释。
目录一、总说明 (3)二、报表目录 (4)三、调查表式(一)北京市供热运行管理单位基本情况调查表1、供热运行管理单位性质及隶属关系况 (5)2、供热运行管理单位基本情况 (6)3、供热运行管理单位人员构成情况 (8)4、供热运行管理单位能源消耗情况 (9)5、供热运行管理单位经营情况 (10)(二)北京市供热锅炉(机)房基本情况调查表1、锅炉(机)房性质及隶属关系情况 (11)2、锅炉(机)房基本情况 (12)3、锅炉(机)房能源消耗情况 (13)4、锅炉(机)房经营情况145、锅炉(机)房主要设备情况 (15)6、锅炉(机)房供热管网情况 (16)(三)北京市换热站基本情况调查表1、换热站性质及隶属关系情况 (17)2、换热站基本情况 (18)(四)北京市采暖用户基本情况调查表1、住宅楼栋居民明细表 (19)2、住宅楼栋底商明细表 (20)3、公共建筑楼栋明细表 (21)四、附录指标解释 (22)一、总说明(一)统计目的为加强供热管理,指导各级政府部门科学制定供热发展规划及相关政策,促进本市供热管理数字化,根据《中华人民共和国统计法》和《北京市统计条例》的规定,特制定本统计报表制度。
天津市居住建筑四步节能设计技术指标(征求意见稿)由市建交委建筑节能和科技处组织的天津市居住建筑节能第四阶段节能(四步节能)设计标准的编制工作,经广泛调研和多次组织专家评审论证,本着严格遵照国家标准《严寒和寒冷地区居住建筑节能设计标准》JGJ26-2010的相关规定,在《天津市居住建筑节能设计标准》DB29-1-2010的基础上,再节约30%的能耗作为我市第四阶段的节能目标。
为合理设定节能目标的基准值,仍以1980 -1981年住宅通用设计4个单元6层楼,体形系数为0.30左右的建筑物的耗热量指标为基准值,将居住建筑的采暖能耗降低75%作为节能目标,主要由建筑物和采暖系统共同承担,按此目标对建筑、热工、采暖、给排水和电气设计提出节能措施要求。
现通过对居住建筑节能设计进行数据采集、整理、市场发展调研和太阳能等再生能源应用现状及未来发展趋势分析等,初步拟定我市居建四步节能设计的技术指标。
一、建筑围护结构节能设计1.居住建筑体形系数根据国家标准《严寒和寒冷地区居住建筑节能设计标准》JGJ26-2010,考虑天津地区气候条件,冬、夏季太阳辐射强度、风环境、围护结构构造等各方面因素,权衡利弊,并兼顾不同类型的建筑造型,经过对天津市60栋建筑进行测算,四步节能设计体形系数按国家现行标准执行。
详见表1。
表1 居住建筑体形系数限值2.居住建筑窗墙面积比限值考虑居住建筑设计的灵活性及功能的合理性,依据国家标准的要求,四步节能设计窗墙面积比限值仍按照《天津市居住建筑节能设计标准》DB29-1-2010执行。
同时规定玻璃及透明部分的太阳辐射透过率不应小于0.60,使冬季室内能够得到更多的太阳能辐射热。
详见表2。
表2 居住建筑的窗墙面积比限值3.围护结构热工性能参数根据对天津市建筑工程实例进行的数据分析,并汲取北京市、黑龙江省、吉林省三地先进的节能设计经验,将四步节能设计中围护结构热工性能参数限值作了调整。
详见表3。
表 3 围护结构热工性能参数限值4.外窗综合遮阳系数限值为了有效地减少居住建筑室内夏季热辐射的影响,四步节能设计对外窗综合遮阳系数限值作了调整。
71规划设计0、引言目前,建筑能耗占社会商品总能耗的比例约为30%,其中住宅建筑约占60%。
此外,我国每年建成房屋面积高达20亿平方米,其中95%以上被列为高耗能建筑。
在同气候条件下,我国建筑总耗热量是发达国家的4倍,住宅单位面积采暖能耗偏高2~3倍,建筑节能迫在眉睫[1]。
根据简毅文[2]等研究结果,冬季采暖能耗是北方城镇住宅建筑能耗的主要部分,其中北京城区住户的采暖能耗均占到全年总能耗的 50% 以上。
张洪恩[3]等研究表明,不同年代的建筑单位面积能耗存在明显差异。
胡珊[4]等研究表明,扁平建筑空间分布体型系数较小,会降低建筑采暖能耗,而塔式建筑冬季供暖能耗相对较高。
张卫华[5]等对西安市69栋住宅楼不同面积的户型采暖能耗进行分析。
结果表明,建筑面积越大,单位面积采暖能耗越小。
顾吉浩[6]等对唐山市某三步节能住宅小区的建筑能耗进行分析,其中建筑平均耗热量为20.4W/m 2。
在上述基础上,本文对唐山市25个典型住宅小区(共计12945户)的建筑类型、建筑年代、建筑面积等进行调研分析,同时对建筑冬季采暖状况以及通断时间面积法采暖能耗进行总结分析,旨在为进一步指导住宅建筑热计量与节能降耗工作提供参考依据。
1、建筑概况唐山市处于寒冷气候热工分区(II-A),冬季寒冷,夏季凉爽。
按照《民用建筑节能设计标准》唐山市计算采暖期天数为127d ,对应室外平均气温为-2.9℃。
但在实际采暖期间,供热部门会根据具体的天气状况调整采暖时间。
近5年唐山市平均冬季供热时间为139d ,以2013~2014年采暖季为例, 总供热时间为131d ,即2013年11月10日至2014年3月20日。
本文对唐山市25个典型住宅小区(共计12945户)的建筑类型、建筑年代、建筑面积等进行调研分析,同时对建筑冬季采暖状况以及通断时间面积法采暖能耗进行分析。
为保证数据准确性,本次调研的建筑群位置较为分散,基本覆盖整个唐山市区。
建筑年代跨越时间较长,最早为唐山市住宅建筑通断时间面积法热计量采暖能耗分析*赵灵1,赵璐1,樊永霞1,冉明士21. 唐山市建筑节能办公室;2. 河北工业大学 能源与环境工程学院摘要关键词对唐山市25所小区住宅建筑的通断时间面积法热计量采暖能耗进行了统计分析。