2017年全球移动数据流量将增长300%
- 格式:pdf
- 大小:73.18 KB
- 文档页数:1
Dedicated designed for High Voltage and High Current application• On waf er high power device measurement up to 10 kV/600 A• Gold plated chuck surf ace f or minimum contact re-sistance and vacuum holes optimized f or thin waf er handling down to 50 µm • Taiko wafer chuck option•Dedicated high voltage and high current probes • Anti-arcing solutionsWaferWallet ® Option• Designed with five individual trays for manual, ergono-mic loading of 150, 200, or 300 mm “modeling” wafers • Fully-automated tests with up to five identical wafers at multiple temperatures• Unique capability to load/unload wafers at any tem-perature MPI ShieldEnvironment™ for Accurate Measurements • Designed for Advanced EMI / RFI / Light-Tight Shielding • fA low-leakage capabilities• Ready for temperature range -60 °C to 300 °CErgonomic Design and Options• Easy wafer or single DUT loading from the front • Integrated active vibration isolation• Completely integrated prober control for faster, safer and convenient system and test operation• The Safety Test Management (STM™) with automated dew point control• Reduced footprint due to smart integration of the chiller • Instrument shelf option f or shorter RF cables provi-ding the highest measurement dynamicMPI TS3500-HP | 300 mm Automated Probe SystemFor accurate and reliable High Power measurementsFEATURES / BENEFITSWAFERWALLET ® SPECIFICATIONSSTAGE SPECIFICATIONSChuck Theta Stage (Programmable)Travel range± 5.0°Resolution 0.0001° (0.24 µm @ 300mm edge)Accuracy < 2.0 µm (measured at the edge of the 300 mm chuck)Repeatabilty < 1.0 µmTheta stage driveHigh resolution stepper motor with linear encoder feedback systemPROBE PLATENLarge Probe Platen supporting up to 8x DC or 4x DC + 4x RF MicroPositioners or standard 4.5” probe card holderSTAGE SPECIFICATIONSChuck XY Stage (Programmable)Travel range 305 mm x 520 mm (12.0 x 20.5 in)Resolution 0.5 µmAccuracy ± 2.0 µm (0.08 mils)Repeatability ± 1.0 µmXY stage drive Closed-loop high precision stepper motors Speed*Slowest: 10 µm / sec | Fastest: 50 mm / secChuck Z Stage (Programmable)Travel range 30 mm (1.18 in)Resolution 0.2 µm Accuracy ± 2.0 µm Repeatability ± 1.0 µmZ stage drive Closed-loop high precision stepper motor Speed*Slowest: 10 µm / sec | Fastest: 20 mm / sec GuiderPrecision ball bearings*The speed is instantaneous speed, not average speed. There is accelerate and decelerate time when moving.ShielDEnvironment™MPI ShielDEnvironment™ is a high performance local environmental chamber providing excellent EMI- and light-tight shielded test environment for ultra-low noise, low capacitance measurements.MPI ShielDEnvironment™ allows for testing with up to 4-port RF or up to 8-ports DC/Kelvin or a combination of those configurations. MPI ShielDCap™ provides easy reconfiguration of measurement setup as well as EMI/noise shielding - These all makes a great difference to conventional systems, especially in a day-to-day operation.ShielDEnvironment™ Electrical Specifications*EMI shielding> 30 dB (typical) @ 1 kHz to 1 MHzLight attenuation≥ 130 dBSpectral noise floor≤ -180 dBVrms/rtHz (≤ 1 MHz)System AC noise≤ 5 mVp-p (≤ 1 GHz)*Including 4 MicroPositioners.MPI NoiseShield™ Option for 1/f (Flicker) & RTN MeasurementsMPI’s exclusive NoiseShield™ offers in combination with MPI ShielDEnvironment™ for unsurpassed active EMI-Shielding of DUT and the measurement instrument (such as pre-amplifier unit). In addition, it provides all cables and connectors close to DUT.The NoiseShield™ option provides shortest possible cable lengths to reduce parasitic capacitance and to maximize test system roll-off frequency. It reduces external magnetic field influences on the measurement results and makes the 1/f, RTN Setup more robust and test lab location less independent.Low impedance cables (for DC or RF pad design), excellent low-impedance system’s grounding and ferrite cores on the unique MPI Kelvin probes are part of the delivery in order to make the probe station completely “invisible” and the measurement results to reach the limit of the instrumentation.SAFETY MANAGEMENTLight CurtainLight Curtain Interlock protects user f rom accidental high voltage shock by shutting down the instrument through interlock system. The interlock system at rear doors provides safety, easy and convenient initial mea-surement set-up.WAFER LOADINGLoading or unloading of 150, 200 or 300 mm wafers or substrates is straight forward and intuitive. Special design of the chuck provides easy loading of a single IC of wafer fragments from the system front. SmartVacuum TM tech-nology automatically recognizes size of the wafer on single IC. It also protects the wafer from unexpected release of vacuum due to inexperienced operation when the wafer is located in the IceFreeEnvironment TM .Easy access to the AUX chucks serves for quick exchange of RF calibration substrates, probe cleaning and plana-rization accessories.Probe Hover Control™MPI Probe Hover Control PHC™ allows easy ma-nual control of probe contact and separation to wafer. Separation distance can accurately control with micrometer feedback for probe to wafer/pad positioning. Ease of use guarantees the saf est operation by minimizing error during critical set-up and probe change operations.THERMAL CHILLER INTEGRATIONPicture is courteously provided by ERS.Minimized CDA ConsumptionThe CDA consumption is reduced by as much as 50% by purging IceFreeEnvironment TM with the re-used cold air of the chiller. Additional automated valve enables purge by Nitrogen*.Additionally, recycled CDA cools the system probe platen and the probe card.*ERS patented technology.Thermal chuck touchscreen control display is an alternative way of interaction with the thermal system. Its ergo-nomic location supports an operator when keying commands and monitoring system status. The fully integrated intelligent hardware control panel is design for intuitive and safe system control and operation. All these signifi-cantly increase the speed and improve convenience of the system interaction work flow.The keyboard and mouse are placed on the sliding tray right below the system control panel. Both can control test instrumentation, if required.USB port is also in front of the system. It removes any hassles when exchanging data.INTEGRATED CONTROLSUnique and revolutionary multi-touch operation soft-ware SENTIO® controls MPI automated engineering pro-be systems. Its simple and intuitive operation concept signif icantly saves operator training time. Scroll, Zoon, and Move functions mimic modern smart mobile device interface. Switching between applications is just a mat-ter of a simple finger swipe.SENTIO® makes everyone the system operation expert in just minutes.SOFTWARE SOLUTIONHigh Voltage Probes (HVP)Low leakage probes specially designed to withstand high voltage up to 10 kV (coaxial) and 3 kV (triaxial). Choice of various connectors options such as Keysight Triax/UHV, Keithley Triax/UHV, SHV or Banana.HIGH POWER PROBESHigh Current Probe (HCP)High performance probes specially designed for on wa-f er measurement of high current up to 200 A (pulse). MPI multi-fingers high current probes are single piece consturction to efficiently handle high current and pro-vide low contact resistance.HIGH POWER PROBES - SELECTION GUIDE[2]Keysight or Keithley [3]Banana: 100 A max, 1 ms max PW, 1% max PLC [4]BNC: 40 A max, 1 ms max PW, 1% Max PLCUltra High Power Probe (UHP)Designed f or Ultra high voltage and current on waf er measurement up to 10 kV/600 A (pulse). MPI replaceable multi-fingers probes tips and probe arms are design for low contact resistance for ultra-high current measure-ment and to support ultra-high voltage of up to 10 KV, without having to change probes for high voltage and current application.UL TRA HIGH POWER PROBES - SELECTION GUIDEUL TRA HIGH POWER PROBESHigh current probeDIMENSIONSUltra High Power probeOptional Anti-Arcing Probe CardIn addition, MPI is offering optional temperature controlof the pressurized air in a range of 20 to 200 °C, whichcorrelate direct with the chuck set temperature.High-voltage testing without arcing at higher tempera-tures are possible now.ANTI-ARCING SOLUTIONSOptional Anti-Arcing LiquidTray™Specially designed anti-arcing LiquidTray™ can be used for arcing suppressing by simply place on the high power chuck surface. Wafers can be safely placed inside the tray to submerge in the liquid for arcing free high voltage test.MICROSCOPE MOVEMENTXYZ ProgrammableXY - Travel range*50 x 50 mm / 300 x 300 mmResolution 1 µm (0.04 mils)Repeatability≤ 2 µm (0.08 mils)Accuracy≤ 5 µm (0.2 mils)Z - Travel range140 mmResolution0.05 µm (0.002 mils)Repeatability≤ 2 µm (0.08 mils)Accuracy≤ 4 µm (0.16 mils)*In case of ShielDEnvironment™ X x Y: 25 mm x 25 mmWafer Chuck Standard Triaxial Connectivity Coax BNC (f)Kelvin Triax (f)Diameter 310 mm with 2 integrated AUX areasMaterial Nickel plated aluminum (flat with 0.5 mm holes)Chuck surfacePlanar with 0.5 mm diameter holes in centric sections Vacuum holes sections (diameter)4, 24, 48, 72, 96, 120, 144, 168, 192, 216, 240, 264, 288 mm SmartVacuum™ distribution In front for single DUT 4x4 mm (4 holes) and 75 mm (3 in)In center for 150, 200, 300 mm (6, 8, 12 in)Surface planarity ≤± 5 µm**Rigidity< 15 µm / 10 N @edge*Single DUT testing requires higher vacuum conditions dependent upon testing application.**By using SENTIO® topographyTriaxial RF Wafer Chuck Connectivity Kelvin Triax (f)Diameter 310 mm with 2 integrated AUX chucksMaterial Nickel plated aluminum (flat with 0.5 mm holes)Chuck surfacePlanar with 0.5 mm diameter holes in centric sections Vacuum holes sections (diameter)4, 24, 48, 72, 96, 120, 144, 168, 192, 216, 240, 264, 288 mm SmartVacuum™ distribution In front for single DUT 4x4 mm (4 holes) and 75 mm (3 in)In center for 150, 200, 300 mm (6, 8, 12 in)Surface planarity ≤± 5 µm**Rigidity< 15 µm / 10 N @edge*Single DUT testing requires higher vacuum conditions dependent upon testing application.**By using SENTIO® topographyAuxiliary Chuck Quantity 2 AUX chucksPositionIntegrated to front side of main chuck Substrate size (W x L)Max. 25 x 25 mm (1 x 1 in)Material Ceramic, RF absorbing material for accurate calibration Surface planarity ≤± 5 µmVacuum controlControlled independently, separate from chucksElectrical Specification (Triax)NON-THERMAL CHUCKSHIGH POWER THERMAL CHUCKSCooling rates** (faster w. -60°C chiller)25 to -10 °C< 15 min / <28 min< 17 min / < 30 min< 20 min25 to -40 °C< 35 min / < 55 min< 40 min / < 65 min< 60 min20 to -60 °C< 40 min< 45 min< 90 min200 to 35 °C< 28 min< 30 min< 40 min200 to 25 °C< 28 min< 30 min< 40 min300 to 35 °C N/A N/A< 50 min300 to 25 °C N/A N/A< 60 min Leakage@ Voltage and:10 V 1.1 kV10 V 3 kV10 V 3 kV10 kV @ -60 °C< 2 pA< 220 pA< 300 fA< 100 pA< 30 fA< 10 pA < 6 nA @ 25 °C< 1 pA< 110 pA< 150 fA< 50 pA< 15 fA< 5 pA < 6 nA @ 200 °C< 1 nA< 110 nA< 300 fA< 150 pA< 30 fA< 10 pA < 15 nA @ 300 °C N/A N/A N/A N/A< 50 fA< 15 pA < 40 nACapacitanceForce-to-Guard < 1600 pF < 600 pF < 600 pF Guard-to-Shield< 2000 pF < 2000 pF < 2000 pF Residual CapacitanceN/A≤ 2.5 pF≤ 2.5 pF* Taiko-wafer support is optional available, please contact M PI local technical support.** Typical values, depends on chiller type and facility supply, please check MPI FPS for the certain chuck and system.TYPICAL TRANSITION TIME102030405060708090100-100-50050100150200250300350time [min]t e m p e r a t u r e [°C ]MPI & ERS AirCool PRIME RF Chuck -60°C to +300°CMPI & ERS AirCool PRIME RF Chuck +20°C to +300°C5101520253035404550556065050100150200250300350time [min]t e m p e r a t u r e [°C ]102030405060708090100110-100-50050100150200250300350t e m p e r a t u r e [°C ]time [min]MPI & ERS AirCool PRIME Ultra Low Noise Chuck -60°C to +300°C510152025303540050100150200250300350t e m p e r a t u r e [°C ]time [min]MPI & ERS AirCool PRIME Ultra Low Noise Chuck +20°C to +300°CERS AirCool ® (patented) ControllerIntegrated Chiller -60 °C ERS AirCool ® (patented) ControllerIntegrated Chiller -40 °CERS and MPI’s joint product AirCool® PRIME Chuck won “Electronics Industry Awards 2018” in the category, “Test, Measurement and Inspection Product of the year”.REGULATORY COMPLIANCE3rd party, TÜV tested according to• IEC 61010-1: 2010 + A1:2016; EN 61010-1: 2010; IEC/EN 61010-2-010: 2014; IEC/EN 61010-2-081: 2015; EN ISO 12100: 2010; UL 61010-1: 2012/R: 2016-04; UL 61010-2-010: 2015; CAN/CSA-C22.2 No. 61010-1: 2012/U2: 2016-04; CAN/CSA-C22.2 No. 61010-2-010:2015and certified for CE and US/Canada (NRTL), SEMI S2 and S8.Copies of certificates are available on requestWARRANTY• Warranty*: 12 months• Extended service contract: contact MPI Corporation for more information*See MPI Corporation‘s Terms and Conditions of Sale for more details.FACILITY REQUIREMENTSSYSTEM CONTROLLER SPECIFICATIONSGeneral Probe System Power 100-240 V AC nominal ; 50/60 Hz Vacuum -0.9 bar Compressed air6.0 barCPU Intel® Core TM i7-7700, 3.6 GHz, 8M Cache, 14nm, 65W TDP, LGA1151(4C/8T)RAMDDR4 2400 MHz 16 GB x 164 bit operating system Windows 10 Professional (English)Power 460 W Storage SSD 500 GBLAN One internal and one external TCP/IP ports USB Ports Internal (on PC) x3, external x1GPIB interfaceOptionalSUPPORTED SOFTWARE PLATFORMSDriversWaferPro / IC-CAP & EasyEXPERT from Keysight, BSIMPro & NoisePro from ProPlus, ACS from KeithleyEmulation modeAvailable for various prober control software** Please contact your local support for more details.TS3500-HPSystem dimensions (W x D x H) 1400 x 1505 x 1730 mm (55.1 x 59.3 x 68.1 in)Weight1150 kgPHYSICAL DIMENSIONS*Can increase depends on operator manual adjustment or interaction.MPI Global PresenceDirect contact:Asiaregion:****************************EMEAregion:******************************Americaregion:********************************MPI global presence: for your local support, please find the right contact here:/ast/support/local-support-worldwide© 2023 Copyright MPI Corporation. All rights reserved.WaferWallet ®System dimensions (W x D x H) 500 x 1270 x 980 mm (19.7 x 50.0 x 38.6 in)Weight200 kg*Can increase depends on operator manual adjustment or interaction.TS3500-HP with WaferWallet ®。
InterRanger DPS 300是一个基于微处理器的污泥层厚度检测系统,可检测两个水和/或废水的初级、次级澄清池中的泥位。
用1或2个非接触的Echomax XCT -12超声波传感器和先进的回波处理技术可靠、连续的监视污泥层的厚度,可以显著提高生产效率,增加产出量和降低污泥处理的费用。
通过RS-232/RS-485或双极性的电流环路通讯,和隔离的mA 输出,提供了中央控制系统集成的可能性。
对于圆形或长方形的澄清池,DPS300的有效测量范围是1m~30m 。
具有自清洁功能的超声波传感器延长了毋需维护的放置时间周期。
对水和污水处理厂来说InterRanger DPS300是有投资效益的系统,始终如一的污泥物位监视数据能直接改善出水的质量。
产品特点y 双频率精确检测监测器y 可提供铝制安装支架装配y 4个可编程的报警/控制继电器y Dolphin Plus 和SmartLinx®兼容技术规格供电• 100/115/200/230 Vac ±15%,50/60 Hz, 31VA 环境条件• 位置: 室内/户外• 环境温度: -20~50℃• 相对湿度: 适合于户外使用(Type 4X/NEMA 4X/IP65外壳)• 安装种类: II • 污染等级: 4扫描点数• 2点/DPS 300精度• 编程量程的1%或2cm, 取其较大者分辨率• 编程量程*的1%或2cm, 取其较大者存储器• 非易失性的电可擦除只读存储器EEPROM ,无需后备电池编程• 通过手持编程器或Dolphin Plus 选件显示器• 51×127mm 常规的带背光图形液晶显示器LCD 外壳• Type 4X/NEMA 4X/IP65聚碳酸酯材料温度补偿• -50~150℃• 内置的温度传感器,最多2个TS-3温度传感器,可编程固定温度• 温度误差:带温度补偿:量程的0.1%• 固定温度:与编程温度每偏差1℃误差为0.22%超声波传感器• 兼容型号: Echomax® XCT-12(量程1~30m )电缆• 同轴电缆采用低电容的RG62-A/U• mA 输出信号线采用2-3芯铜线绞合,金属箔屏蔽电缆,和接地线,300V0.5~0.75mm 2(22~18AWG )• 继电器/电源线采用满足250V, 5A 触点要求的铜导线输出超声波传感器驱动• 150~315V 峰值继电器• 4个报警/控制继电器• 每个继电器带1组“C”型SPDT (单刀双掷)触点,额定容量为5A, 250Vac 无感mA• 2路输出,分辨率0.1%,• 0/4~20mA ,可标定,• 最大负载750Ω,隔离,30V rms 重量• 2.7Kg (6 Ibs.)选项温度传感器• TS-3通讯• SmartLinx: 指定协议的模块用于与通用工业通讯系统接口• Dolphin Plus: 妙声力Windows 兼容的接口和红外转换器• BIC-Ⅱ:DPS300双极性通讯电流环到远程的RS-232或RS-422接口撇渣机保护罩• 2种模式—A 型(20cm(8”))或B 型(40cm(16”))• 温度:-40~80℃(-40~176℉)• 结构:有铰链带保护罩的不锈钢导管和有铰链的氯丁橡胶保护套筒• 连接:±90°于垂直方向• 重量:A 型—1.4Kg ,B 型—2.1Kg 安装配件• 栏杆,一般为直径等于或小于50mm (2”)管子,2导轨中心间距为432mm ~610mm • 温度:-40~80℃• 构造:环氧涂覆的铝,不锈钢紧固件• 重量:6.5Kg 认证• CE**, CSA NRTL/C FM (正在申请),*编程量程是指空仓到超声波传感器表面的距离加上量程延伸。
维萨拉工业测量产品手册湿度 | 温度 | 露点 | 二氧化碳 | 沼气 | 油中水分 | 连续监测系统 |溶解气体分析系统 | 过氧化氢 | 压力 | 气象 | 服务支持观测让世界更美好维萨拉的工业测量业务领域产品能够帮助客户了解工艺过程。
我们的产品为客户提供准确可靠的测量数据,帮助客户做出优化工业过程的决策,从而提高过程效率、产品质量、生产力和产量,同时减少能源消耗、浪费和排放。
我们的监测系统还能帮助客户在受监管的环境中运营,以履行监管合规性。
维萨拉工业测量服务于多种类型的运营环境,从半导体工厂和高层建筑,到发电厂和生命科学实验室,对环境条件的可靠监测是实现成功运营的先决条件。
维萨拉的测量产品和系统广泛应用于监测温度、湿度、露点、气压、二氧化碳、汽化过氧化氢、甲烷、油中水、变压器油中溶解气体和液体浓度等参数。
我们的生命周期服务可在测量仪表的整个使用寿命内提供维护。
作为值得信赖的合作伙伴,我们通过在产品和系统生命周期中保证准确的测量数据来支持客户做出可持续的决策。
本产品目录对我们的产品进行整体的介绍,以帮助您选择适合您需求的产品。
如需更多信息,请通过以下方式联系我们:销售热线:400 810 0126电子邮箱:**********************公司网址:扫描二维码,关注维萨拉企业微信3目 录Indigo系列变送器Indigo200系列数据处理单元 (7)Indigo300数据处理单元 (9)Indigo510数据处理单元 (12)Indigo520数据处理单元 (15)用于抽检和校准的手持设备Indigo80手持式显示表头 (18)HMP80系列手持式湿度和温度探头 (21)DMP80系列手持式露点和温度探头 (23)HM70手持式湿度和温度仪 (26)HUMICAP® 手持式湿度温度仪表HM40系列 (29)DM70手持式露点仪 (33)MM70适用于现场检测的手持式油中微量水分和温度测试仪 (36)湿度和温度用于测量相对湿度的维萨拉HUMICAP® 传感器 (38)如何为高湿度应用选择合适的湿度仪表 (40)Insight PC机软件 (44)HMP1墙面式温湿度探头 (46)HMP3一般用途湿度和温度探头 (48)HMP4相对湿度和温度探头 (51)HMP5相对湿度和温度探头 (54)HMP7相对湿度和温度探头 (57)HMP8相对湿度和温度探头 (60)HMP9紧凑型湿度和温度探头 (63)TMP1温度探头 (66)适用于苛刻环境中湿度测量的HMT330系列温湿度变送器 (68)HMT370EX系列本安型温湿度变送器 (78)HMT310温湿度变送器 (84)HUMICAP® 温湿度变送器HMT120和HMT130 (87)适用于高性能暖通空调应用的HMW90系列湿度与温度变送器 (90)HMD60系列湿度和温度变送器 (92)HMD110/112和HMW110/112湿度和温度变送器 (96)适用于楼宇自动化高精度室外测量的HMS110系列温湿度变送器 (99)HMDW80系列温湿度变送器 (101)适用于楼宇自动化应用室外测量的HMS80系列温湿度变送器 (105)HMM100湿度模块 (107)适用于OEM应用的HMM105数字湿度模块 (109)HMM170温湿度模块 (111)INTERCAP® 温湿度探头HMP60 (113)4INTERCAP® 温湿度探头HMP63 (115)HUMICAP® 温湿度探头HMP110 (117)HUMICAP® 温湿度探头HMP113 (120)SHM40结构湿度测量套件 (122)HMK15湿度校准仪 (125)DTR500太阳辐射和雨水防护罩 (127)HMT330MIK气象安装套件 (129)适用于动力汽轮机进气测量的HMT300TMK汽轮机安装组件 (131)露点Vaisala DRYCAP® 传感器用于测量干燥过程中的湿度 (133)DMP5露点和温度探头 (135)DMP6露点探头 (138)DMP7露点和温度探头 (140)DMP8露点和温度探头 (142)DMT340系列露点和温度变送器 (145)适用于高温应用的DMT345和DMT346露点变送器 (151)DMT152露点变送器 (155)DMT143露点变送器 (157)DMT143L露点变送器 (160)用于冷冻干燥机的DMT132露点变送器 (162)DM70用DSS70A便携式采样系统和采样室 (164)DPT146露点和气压变送器 (166)DPT145多参数变送器 (168)二氧化碳适用于苛刻环境的维萨拉CARBOCAP® 测量传感器 (171)GMP343二氧化碳探头 (173)适用于CO2恒温箱的GMP231二氧化碳探头 (176)GMP251二氧化碳探头 (178)GMP252二氧化碳探头 (181)GM70手持式二氧化碳测试仪 (184)适用于苛刻通风要求应用的GMW90系列二氧化碳及温湿度变送器 (187)适用于智能控制通风系统 (DCV) 的GMW80系列二氧化碳、湿度和温度一体变送器 (190)按需控制通风系统中的GMD20系列二氧化碳变送器 (193)GMD110管道安装式二氧化碳变送器 (195)沼气MGP261多气体探头 (197)MGP262多气体探头 (199)油中水用于测量油中微水的维萨拉HUMICAP® 传感器 (201)MMP8油中水分探头 (203)MMT330系列油中微量水分与温度变送器 (205)5MMT310系列油中微量水分与温度变送器 (209)MMT162油中微量水分和温度变送器 (211)连续监测系统维萨拉viewLinc企业版服务器版本5.1 (213)AP10 VaiNet无线接入点 (215)用于连续监测系统的RFL100无线数据记录仪 (218)HMP115温湿度探头 (223)TMP115宽范围温度探头 (225)维萨拉温度与相对湿度数据记录仪系列DL2000 (227)维萨拉通用输入数据记录仪系列DL4000 (229)维萨拉多应用温度数据记录仪DL1016/1416 (231)维萨拉热电偶数据记录仪系列DL1700 (233)维萨拉中端温度、湿度及触点通道数据记录仪 (235)维萨拉vNet以太网供电数据记录仪接口 (238)溶解气体分析OPT100 Optimus™ 溶解气体分析(DGA)监测系统 (240)MHT410变压器油中微量水分、氢气和温度分析仪 (244)过氧化氢用于测量汽化过氧化氢、相对饱和度和相对湿度的维萨拉PEROXCAP® 传感器 (246)用于过氧化氢、湿度和温度测量的HPP270系列探头 (249)压力用于测量压力的维萨拉BAROCAP® 传感器 (253)PTU300气压、湿度和温度一体变送器 (255)适用于专业气象、航空与工业用户的PTB330数字式气压计 (260)气压传递标准PTB330TS (262)PTB210数字气压计 (265)PTB110气压计 (267)将风引起误差降低的SPH10/20静压头 (269)气象Vaisala用于工业应用测量的风和气象传感器技术 (271)风测量装置WA15 (273)WINDCAP® 超声波风传感器WMT700系列 (276)气象变送器WXT530系列 (278)服务支持面向仪表全生命周期服务 (280)67功能•数据处理单元 USB-C 端口支持使用通用 USB 电缆连接到维萨拉Insight PC 软件•数字和图形彩色显示屏(针对模拟型号提供可选的不带显示屏的款式)•IP65 外壳•24 V AC/DC 电源输入•Indigo201:3 个模拟输出(mA 或 V)•Indigo202:RS-485,带有Modbus ® RTU•2 个可配置的继电器维萨拉 Indigo200 系列数据处理单元是一种主机设备,它显示来自维萨拉 Indigo 兼容探头的测量值,同时也可通过模拟信号、Modbus RTU 通信或继电器将这些测量值传输到自动化系统。
The AT-UHD-HDVS-300-KIT provides AV switching, USB and HDMI extension, plus systemcontrol for meeting spaces using PC-based conferencing codecs such as Microsoft Skype®, Cisco WebEx® and Citrix GoToMeeting®. The transmitter and receiver kit offers five video inputs shared between both devices for HDMI, DisplayPort, and analog video signals. To simplify conference room device management, the kit provides two USB type B connectors for host computers. Two built-in USB hubs, one on the transmitter and one on the receiver, allow for numerous Human Interface Devices (HID) as well as USB cameras and microphones.AT-UHD-HDVS-300-TX • 1 x Unit• 1 x Female captive screw connector3 pin: RS-232• 4 x Mounting plates • 4 x Rubber feet • 8 x ScrewsAT-UHD-HDVS-300-RX • 1 x Unit• 1 x Pair of wall/table mount ears • 1 x Female captive screw connector2 pin: power3 pin: RS-232• 1 x 48V DC power supply • 4 x Screws Package• 1 x Installation GuidePackage ContentSoft Codec Conferencing SystemAT-UHD-HDVS-300-KIT Installation GuidePlease check /product/AT-UHD-HDVS-300-KIT for the most recent firmware update or manual.Back Panel1. RS-232 port - Connect to a control system or display for pass through RS-232 control2. LAN port - Connect network switch, router, or source to this port for pass through Ethernet, TCP/IP, or AMS control3. HDMI OUT - Connect to a display4. LEDs: PWR - Illuminates when the power supply is connected and sending power Link - Illuminates when receiving signal over HDBaseT5. HDMI IN - Connect local HDMI source6. USB Hub - Connect USB source devices here (e.g. webcam, smartboard, etc)7. HDBaseT IN - Connect to a compatible HDBaseT transmitter (e.g. AT-UHD-HDVS-300-TX)8. DC 48V - Connect included 48V power supplyPanel DescriptionsFront Panel1. Input LEDs - LED will illuminate to display the currently selected input2. Power button - Turns switcher on, places the unit in standby mode, or controls a connected display through the HDBaseT output3. ^ ^ buttons - Controls the volume of the display connected to the HDBaseT output4. Input button - Use to switch between inputs5. USB hosts - Connect to a computer using a USB B to USB A cable6. HDMI IN - Connect HDMI sources to these ports7. Audio IN - Connect analog audio here8. VGA IN - Connect VGA source to this port9. DP IN - Connect DisplayPort source to this port10. USB Hub - Connect USB source signal devices (e.g. mouse, keyboard, etc)11. HDBaseT OUT - Connect to an HDBaseT PoE receiver (e.g. AT-UHD-HDVS-300-KIT)12. RS-232 port - Connect to a control system or source for pass through RS-232 control13. LAN port - Connect network switch, router, or source to this port for pass through Ethernet, TCP/IP, or AMS controlTo affix the mounting plates to the unit, use the 8 screws included in the kit to connect them to the bottom of the UHD-HDVS-300-TX. Once the plates are attached, turn the unit over and mount the unit to any surface using the oval holes in all four plates.To affix the mounting brackets to the unit, use the four included screws as well as the four side case screws. The bracket can be affixed with the oval holes pointing to the bottom (for against the wall - picture A) or the oval holes facing the top (for under tables - picture B).Larger ovalhole will beattached toMountingEthernetFor convenience, the UHD-HDVS-300 comes with DHCP on. This enables the switcher to be connected to a network without knowing available IP addresses. If your network does not allow dynamic IP addresses or if you are using the switcher with a TCP/IP control system, this feature may be turned off and the IP address set using front panel.Captive ScrewThe captive screw connectors allow you to cut cables to a suitable length, reducing cable clutter while providing a more reliable connection.ConnectingThe captive screw connectors havea contact bar that is adjusted tocompress the wire against the top contact plate. Use the screws at the top of the connector to compress the wire against the contact plate.When connecting the cables to the female captive screw connector it is important that the wires be terminated correctly. The female captive screw connector has a contact plate at the top and must have the wires touching it for signal to pass. When wired correctly (see picture A) the signal will pass, incorrectly (see picture B) no signal will pass.Female captive screw connectors are included: Power (see picture 1), RS-232 (see picture 2).The power cable (picture 3) will have exposed wires. Each wire is encased in a different colored cover.1PowerRS-232ClockwiseCounter ClockwiseTurn the screws clockwise toraise the contact bar to theupper contact plate and hold the wires in place.Turn the screws counter clockwise to lower the contact bar to release the wires.2RS-232 pin out will be determined by the RS-232 cable and will connect as Rx(receiver), Tx (transmitter), and (ground). (See picture 4)Typical pin out:2 - TX - Transmitter3 - RX - Receiver 5 - GND - GroundPin out color will differ per RS-232 cable.Black : - White : +- +34543298761Category Cable and ConnectorFor the category cables used in the installation of these products, please be sure to use a 568B termination as pictured below:Connector type and size is very important to ensure extenders work correctly. Please use the matching cable type with the correct RJ45 connector. (e.g. CAT 7 cable should use a CAT 7 connector)Important! 4K (UHD) signals are sensitive to cable quality and installation technique. It is recommended to use CAT6a/7 solid core cables for best results.Note: Press and hold the input button on the front panel to switch between static and DHCP IP address. Two button flashes means the unit is in static mode and four button flashes means the unit is DHCP. Static IP configuration will be: 192.168.1.254 - 255.255.255.0Connection Diagram1. My computer is not detecting the connected USB devicesUSB 1 is the default host port. Use AMS to switch between USB hosts2. My display is not turning on/off when using CECNot all displays support CEC, please verify your display has CEC support3. My HDVS-300 is not switching when I connect a new sourceBy default, auto switching is set to off. It can be turned on in AMS4. My unit is not showing up on my networkPress and hold the input button on the front panel to switch between static and DHCP IPaddress. Two button flashes means the unit is in static mode and four button flashes means the unit is DHCP. Static IP configuration will be: 192.168.1.254 - 255.255.255.0。
This Quick Start Reference provides informationon setting up your instrument for basic operation.The latest complete Communication andOperational Manual as well as free Softwareand ActiveX Controls are available at/specs/iseries or on theCD-ROM enclosed with your shipment. SAFETY CONSIDERATIONThe instrument is a panel mount device protected in accordance with EN 61010-1:2001, electrical safety requirements for electrical equipment for measurement, control and laboratory.Remember that the unit has no power-on switch. Building installation should include a switch or circuit-breaker that must be compliant to IEC 947-1 and 947-3. SAFETY:•Do not exceed voltage rating on the label located onthe top of the instrument housing.•Always disconnect power before changing signal andpower connection.•Do not use this instrument on a work bench withoutits case for safety reasons.•Do not operate this instrument in flammable orexplosive atmospheres.•Do not expose this instrument to rain or moisture.EMC:•Whenever EMC is an issue, always use shielded cables.•Never run signal and power wires in the same conduit.•Use signal wire connections with twisted-pair cables.•Install Ferrite Bead(s) on signal wire close to theinstrument if EMC problems persist.。
Testing HGM 300 with Gas Verification KitUsing PC Software3015-3843 Rev. 2February 2017 This procedure describes the use of gas verification kits with the HGM PC software.MATERIALS REQUIRED▪Reference gas▪Variable flow regulator▪Approximately 5 feet of 3/16” tubing▪Plastic stem connector▪Computer with HGM 300 software installed(available at )PROCEDURE1.Power up the HGM. The green LED on the monitor will blink until the warm-up cycle is complete.2.Connect the variable regulator to the reference cylinder and connect the tubing to the variable regulator.Connect the plastic stem connector to the other side of the tubing.3.Connect the RS232 cable from the PC to the HGM’s RS232 connector located in lower left side of themonitor.NOTE: For instructions on PC software and setup, see the instruction manual.unch the PC software. A series of beeps will sound as the software reads all the HGM registers.5.Verify Rezero Mode is set to auto by reading the system parameter list. If it is not set to Auto, do thefollowing:a.S elect the “Edit Pull down Menu”.b.C hoose the “System” item from the selection list.c.Change the Rezero Mode to “A uto”.d.Press the Enter key to update the setting.∙The program should respond with “System Data Updated”.∙(On version 1.0 software it is necessary to select the “HGM Pull down Menu” and then send the setup in order to confirm the changes)6.Select the “HGM Pull down Menu” and c hoose the setup item from the menu list. This will update the setupfrom the HGM.7.Select the “Edit Menu”and choose “Zones” from the menu item list.8.Select zone by pressing the Enter key. Modify the parameters for Zone 1:a.Change the refrigerant selection to the reference cylinder typeb.Change the distance to 5 ft.c.Press the Enter key, then the ESC key.d.Verify that the PC software recognizes that the HGM Zone data was updated.NOTE: Be sure to wait for response from the PC software. Selecting another menu before the response is echoed will cause the communications to timeout. On version 1.0 software it is necessary to select the “HGM pull down menu” and then send the item to the setup in order to confirm the changes.9.Select “HGM Menu” and choose “Zone Hold” from the menu list.10.Select Zone 1 by pressing the Enterkey. Wait for the PC software todisplay the message, “Holding onZone”.11.Select “Diagnostic Menu” and choose“Sensors” from the menu item list. Thiswill display all of the diagnostic data forthe HGM. Verify that the unit is not in apurge cycle.12.Connect the stem connector end of thetubing from the reference gas regulator toZone 1on the HGM manifold.NOTE: The HGM fault light may illuminate until gas starts to flow from the cylinder.13.Press the Enter key on the PC keyboard to update the PC software reading from the HGM 300. The HGMwill beep to indicate the sensor readings have been updated. Ensure that the HGM 300 is not in purge mode.14.Open the flow regulator knob (turn clockwise) toprovide sample gas, adjusting the flow so the flowmeter ball is at its midpoint (optimal).Press the Enter key on the PC keyboard to updatethe PC software reading from the HGM 300.15.Allow the gas to flow for 1 minute. Continue to press the Enter key on the PC keyboard while observing thefirst PPM reading (6th line) from the sensor data menu.This value will eventually stabilize to (typically) within +5 ppm of final reading. If a purge cycle interrupts the process, the reading will go to 0, but should return to approximately the cylinder value when flow returns to Zone 1. The reading should be within specifications of the actual concentration listed on the cylinder.Remove the sample hose from the unit.16.Close the regulator of the reference cylinder (turn counter clockwise until fully closed). Return Zone 1parameters (length, refrigerant, hold time) to desired operating values.17.If the reading in step 15 is not within specifications of the actual concentration listed on the cylinder, verify:▪The tubing is securely connected to the cylinder and Zone 1 input port▪The proper gas is selected (step 8a)▪The unit is in hold mode for Zone 1 (step 9)▪That ample time was given to stabilize and the reading was not taken during a purge cycle.If the unit still does not measure within specifications of the concentration listed on the cylinder, please contact Bacharach Customer Service at 1-800-736-4666 or via ********************.∇∇∇Bacharach621 Hunt Valley Circle,New Kensington, PA 15068 USANew Kensington, PA USA | Dublin, Ireland | Toronto, Canada|********************。
WARNING: If incorrectly used this machine can cause severe injury. Those who use and maintain this machine should be trained in its proper use, warned of its dangers and should read the entire manual before attempting to set up, operate, adjust or service the machine.OWNER/OPERATOR’S MANUAL & ILLUSTRATED PARTS LIST09-346 REV BMODEL:73-70920TRENCHER TH300CALIFORNIAProposition 65 Warning Diesel engine exhaust and some of its constituents are known to the State of California to cause cancer, birthdefects and other reproductive harm.Californie Proposition 65Avertissement Les échappements des moteurs diesel et certains de leurs composés sont reconnus par l’Etat de Californie pour être cancérigènes, provoquer des défauts congénitaux et d’autres dangers en matière de reproduction.ADVERTENCIAAVERTISSEMENTWARNINGThe engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm.California Advertencia de la Proposicion 65El estado de California hace saber que los gases de escape de los motores diesel y algunos de sus componentes producen cáncer, defectos de nacimiento y otros daños en el proceso de reproducción humana.L’émission du moteur de ce mat ériel contient des produits chimiques que l’Etat de Californie consid ère être canc érig ènes, provoquer des d éfauts cong énitaux et d’autres dangers en mati ère de reproduction.El estado de California hace saber que los gases de escape de este producto contienen productos quÍmicos que producen cáncer,defectos de nacimiento y otros daños en el proceso de reproducción humana.© 2003, TEXTRON INC1TRENCHERIMPORTANT MESSAGEThank you for purchasing this Jacobsen product. You have purchased a world class product, one of the best designed and built anywhere.This product comes with an Owner/Operator's Manual. The useful life and good service you receive from this product depends to a large extent on how well you read and understand this manual. Treat this product properly and adjust it as instructed, and it will give you many years of reliable service.See a Jacobsen dealer for any service or parts needed. Jacobsen service ensures that you continue to receive the best results possible from Jacobsen products. You can trust Jacobsen replacement parts because they are manufactured with the same high precision and quality as the original parts.Jacobsen designs and builds its equipment to serve many years in a safe and productive manner. For longest life, use this product only as directed in the manual, keep it in good repair and follow safety warnings and instructions. You'll always be glad you did.Jacobsen, a Textron CompanyOne Bob Cat LaneJohnson Creek, WI 53038-04691-2005TABLE OF CONTENTS FIGURES PAGE DESCRIPTION / SPECIFICATIONS..............................................................................................................2SAFETY .....................................................................................................................................................3, 4INSTALLATION ..............................................................................................................................................5OPERATION ..................................................................................................................................................6SERVICE .......................................................................................................................................................7MAIN FRAME & SHIELDS.................................FIGURE 1.....................................................................8, 9DRIVE PARTS ...................................................FIGURE 2..................................................................10, 11BOOM & CHAIN ASSEMBLY.............................FIGURE 3.................................................................12, 13HYDRAULICS....................................................FIGURE 4.................................................................14, 15GEAR BOX ........................................................FIGURE 5.................................................................16, 17CRUMBER.........................................................FIGURE 6.................................................................18, 192TRENCHERDESCRIPTION / SPECIFICATIONSSPECIFICATIONSOverall Width ...............................................................................37"Overall Height..............................................................................34"Overall Length .............................................................................64"Total Weight ................................................................................395 lbs.Auger Diameter............................................................................12"Chain Speed ................................................................................550 ft./min.Drive Shaft (diameter).................................................................1-1/2"Cutting Depth (max)....................................................................28"Cutting Width ...............................................................................4-3/4"DESCRIPTIONThe trencher is designed to perform with the Steiner 4-wheel drive articulated frame steering tractors. The trencher mounts on the quick hitch front lift in the conventional manner. Driven by a PTO belt, a right angle gearbox provides a 2 to 1 reduction providing power to the trencher digging chain. The depth of trench is regulated by a cylinder controlled by the auxiliary hydraulic system of the power unit.Features include:•Visible depth indicator.•Front mount Quick Hitch.•Variable depth control.•High performance bearings throughout.•Quick chain tension adjustment.•Heat treated carbide tip chain.Trencher easily follows line of trench, cutting to a maximum depth of 28 inches. The depth of cut is easily adjustable during operation indicated by the highly visible depth gauge.3TRENCHERSAFETYNOTICEUnauthorized modifications may present extreme safety hazards to operators and bystanders and could also result in product damage.Jacobsen, a Textron Company strongly warns against, rejects and disclaims any modifications,add-on accessories or product alterations that are not designed, developed, tested and approved by Jacobsen Engineering Department. Any Jacobsen product that is altered, modified or changed in any manner not specifically authorized after original manufacture–including the addition of “after-market”accessories or component parts not specifically approved by Jacobsen–will result in the Jacobsen Warranty being voided.Any and all liability for personal injury and/or property damage caused by any unauthorized modifications,add-on accessories or products not approved by Jacobsen will be considered the responsibility ofthe individual(s) or company designing and/or making such changes. Jacobsen will vigorously pursue full indemnification and costs from any party responsible for such unauthorized post-manufacture modifications and/or accessories should personalinjury and/or property damage result.This symbol means:ATTENTION!BECOME ALERT!Your safety and the safety of others is involved.Signal word definitions :The signal words below are used to identify levels of hazard seriousness. These words appear in thismanual and on the safety labels attached to Jacobsen machines. For your safety and the safety of others, read and follow the information given with these signal words and/or the symbol shown above.DANGER indicates an imminently hazardous situation which, if not avoided, WILL result in death or serious injury.WARNING indicates a potentially hazardous situation which, if not avoided, COULD result in death or serious injury.CAUTION indicates a potentially hazardous situation which, if not avoided, MAY result in minor or moderate injury. It may also be used to alert against unsafe practices or property damage.CAUTION used without the safety alert symbol indicates a potentially hazardous situation which, ifnot avoided, MAY result in property damageSAFETYTRENCHERGENERAL SAFETY1.Read and understand the Owner’s Manual before attempting to operate this machine.2.Operate all controls from the operator’s seat. NO RIDERS.3.Keep all shields in place and safety switches adjusted properly.4.Do not leave equipment unattended. STOP the engine and remove the key.5.Do not allow minors or the inexperienced to operate this machine.6.Keep people and pets a safe distance away from machine using power driven attachments. Injurycould result from flying debris.4TRENCHERINSTALLATIONMOUNTING INSTRUCTIONSThe trencher should be used only on Steiner4-wheel drive power units equipped with hydraulic auxiliary couplers.To mount the trencher do the following steps: 1.Open quick hitch latches. Drive tractor intoposition, aligning the quick hitch. Be sure thatboth latches are fully engaged and locked.2.Stop engine to install drive belt. See power unitoperator’s manual for drive belt installation and tension adjustment.3.Remove clip pin from support stand and raisestand to transport position. Secure stand withclip pin.4.Connect hydraulic hoses to the auxiliarycouplers. If auxiliary hydraulic lever seems tooperate in the wrong direction, connect thehoses in the opposite couplers.UNMOUNTING INSTRUCTIONS1.Choose a level site to remove the trencher.2.Lower the support stand and secure with clippin.3.Lower the front lift. Lower the boom and applyslight down pressure.4.Set parking brake and stop engine.5.Disconnect hoses from the quick couplers.6.Remove drive belt.7.Open quick hitch latches. Start engine andback power unit away from the trencher.5OPERATIONTRENCHER6TRENCHERSERVICESERVICE SCHEDULEEvery 4 Hours:•Grease the boom pivot tube.Daily:•Check for any signs of loose bolts and tighten as needed.•Check digging chain for missing or broken cutters. Repair as needed. Check diggingchain tension.•Wash boom, digging chain and auger at the end of each workday.25 hour:•In addition to daily service, lubricate the roller chain with chain lube or SAE 30 motor oil.•Check gearbox oil level. Oil level is 4 inches down from the top of filler tube. Use #90 gearoil.100 hour:•Change gearbox oil at 100 hours or four weeks initially, and every 2500 hours or sixmonths of operation thereafter. Use #90 gearoil.ADJUSTMENTSDrive belt tension:•See the power unit operators manual foradjustment of drive belt tension.Roller chain drive:•Adjustment is by a spring loaded idler.Digging chain tension:•Adjust with large set screw in the center of boom. Loosen jam nut and tighten set screwuntil chain has 1/4 inch to 1/2 inch gap whenlifted from the boom at mid—point. Tightenjam nut.Crumber adjustment:•The crumber should be close to, but nottouching, the digging chain at any time. Theunit may need to be moved out as the diggingchain stretches. Choose from three mountinghole positions.NOTE:DO NOT OVERTIGHTEN CHAIN. This will cause undue wear on the boom components.Replacing digging chain:1.Loosen four bolts through the boom.2.Loosen jam nut on the set screw in the center ofthe boom and back out the set screw to allowthe boom to retract.3.Remove the old chain and replace with the newchain.4.Tignten the set screw until the chain is snug.Tighten the jam nut. Tighten the bolts that wereloosened in Step 2.5.Check new digging chain tension (as describedabove) after it has run for 20 minutes, and everyhour of use for the next 4 hours.NOTE: It is normal for a new chain to require frequent tightening.7MAIN FRAME & SHIELDSTRENCHERFIGURE 18TRENCHERITEM PART NO.DESCRIPTIONQTYITEMPART NO.DESCRIPTIONQTYMAIN FRAME & SHIELDSFIGURE 11-162-823.7MAIN FRAME 1*4116761LBL-MADE IN USA 11-260-625.7SHIELD-AUGER 1*00-223LBL-DANGER STAND CLEAR11-344-140DEFLECTOR BELTING, DIRT 11-464139-08BOLT-5/16-18X3/451-564141-6NUT, 5/16-1851-644-141BELTING, AUGER 11-764-855STRAP, BELTING 11-864123-75BOLT, 3/8-16X3 HEX 31-964141-4NUT-WLF 3/8-16101-1064139-24BLT-WLF 3/8-16 X 141-1164-849CLAMP, BELTING 11-124134161TUBE AND HOSE CLMP 1/4"21-1301-014SCREW, MACHINE 8-32 X 111-1464025-29NUT-HEX #8-32 KEPS 21-1564-834.7FOOT STAND W/A 11-1664123-87BOLT-HEX 3/8-16X1-3/411-1764229-03LOCKNUT-NYLON 3/8-1611-1803-0616CLEVIS PIN, 3/8 X 211-1902-PP0313PIN, 3/16 x 1.5/811-2060-626.7SHIELD, DRIVE BELT 1*00-025LBL-HANDS & FEET 11-2190-0808BOLT 41-2264163-67WASHER-.516X1X12GA 41-2364006-05LOCKWSHR-HELICAL 1/241-2464139-02BLT-WLF 1/4-20X1/271-2564141-2NUT-WLF 1/4-2011-2664-848.7BRACE, CHAIN SHIELD 11-2760-624.7GUARD, CHAIN 1*00-093LBL-WARN OWNR MAN 1*00-223LBL-DANGER STAND CLEAR11-2864139-21BLT-WLF 3/8-16X3/431-2960-628.7COVER, CHAIN GUARD 1*00-217LBL-MODEL TH3001*00-223LBL-DANGER STAND CLEAR11-3060-629.7COVER, ACCESS 11-3164123-89BOLT-HEX 1/4-20X3/411-3264163-03WSHR-.256ID X.62OD X 1811-3364229-01LOCKNUT-NYLON 1/4-2011-3464-851.7CLAMP, BOOM SWIVEL 11-3564229-02LOCKNUT-NYLON 5/16-1821-3664163-02WSR-.321/.328X.593/.608X1141-3764123-55BLT-HEX 5/16-18X321-3864-847.7CLAMP, BELTING 11-3944-142BELTING, RUBBER 11-4064-861.7STRAP, AUGER BELTING 11-4164152-618-32 X 1 1/4 MACH SCRW 2* NOT ILLUSTRATEDDRIVE PARTSTRENCHER FIGURE 2TRENCHERITEMPART NO.DESCRIPTION QTYITEM PART NO.DESCRIPTION QTYDRIVE PARTSFIGURE 22-162-823.7FRAME, MAIN W/A12-280-192.7AUGER, TRENCHER W/A 12-3CLAMP-AUGER1(SUPPLIED W/64-836)2-464123-171BOLT-HEX 3/8-16X3-1/222-564229-03LOCKNUT-NYLON 3/8-1622-664164-26KEY-3/8x3/8x1-1/2 SQ 32-764-854SPACER-AUGER 1(USED WITH STANDARD DIGGING CHAIN)64-924SPACER-AUGER 1(USED WITH 5-1/2" CHAIN KIT)2-883-041DRV SPRKT-W/ 3/8 KEYWAY 12-960-630.7SHIELD22-1055-1108KRR BRG-FAFNIR W/COLLAR 12-1180-253SHAFT-DRIVE12-1255-RA108RR BRG-FAFNIR W/COLLAR 12-1360-624.7GUARD, CHAIN 12-1487-175GEARBOX, RIGHT ANGLE 12-1529-079PIPE NIPPLE, 1/2 X 1.1/212-1624-033PIPE CAP, 1/2"12-1783-BK85H PULLEY-8.5" H1 BUSHING 12-18D3032BUSHING, H 7/812-1964164-11KEY-3/16X3/16X1-1/4 SQ 12-2081-B050BELT-B511(USED ON 415 & 430)2-2164006-05LOCKWSHR-HELICAL 1/252-2290-0808BOLT42-2383-60Q40SPROCKET, 60Q4012-2456-RC60-42CHAIN-#60 42"181-024CONNECTOR LINK #60181-077HALFLINK-#6012-2583-Q124BUSHING-Q1 X 1-1/2"12-2683-H601220SPRKT-FIXED BORE 1-1/412-2764164-101/4X1/4X1-1/4 MACH KEY 12-2840-322.7ARM, IDLER12-2983-6015E08IDLER SPRKT #60 15TTH 1/212-3085-B29BUSHING,.406 X.740 X.25812-3141-020SPRING12-3264123-70BOLT-HEX 3/8-16X1-1/212-3364123-50BOLT-HEX 3/8-16X112-3464123-24BLT-HEX 1/2-13X212-3564163-61WSHR .81X.406X16GA 22-3664163-67WASHER-.516X1X12GA 22-3764025-09HEX, NUT 1/2-1312-3864141-4NUT-WLF 3/8-1632-3956-068TRIM SEAL 12"1BOOM & CHAIN ASSEMBLYTRENCHER FIGURE 3TRENCHERITEM PART NO.DESCRIPTIONQTY ITEM PART NO.DESCRIPTIONQTY BOOM & CHAIN ASSEMBLYFIGURE 33-162-821.7BOOM1(INCLUDES ITEMS 4 - 11)3-290-0826BOLT,1/2-13 X 3-1/443-364141-13NUT WLF 1/2-1343-492-12NUT,3/4-1013-585-105-372SET SCREW-3/4 X 513-687-105-379BOLT-3/4 X 1-1/413-787-110-054BUSHING 23-887-115-464SNAP RING 13-987-142-755ROLLER 13-1087-125-009BEARING13-1187-183-469IDLER SHAFT 13-1279-080CHAIN-DIGGING 4-3/4"1(STANDARD)*70-125KIT-3-1/2" TRENCHER CHN 1(OPTIONAL)62-861CRUMBER WLDMT 179-098CHAIN-3-1/2" WIDE 1*70-117KIT-5-1/2" TRENCHER CHN 1(OPTIONAL)64-924SPACER-AUGER 179-099CHAIN-5-1/2" WIDE13-1/2" CHAIN REPAIR LINKS3-1379-090REPAIR SECTION 1(CENTER CUT)3-1479-091REPAIR SECTION 3"1(LH STRAIGHT)3-1579-092REPAIR SECTION 3"1(RH STRAIGHT)3-1679-103REPAIR SECTION 1(OFFSET LEFT)3-1779-104REPAIR SECTION 1(OFFSET RIGHT)3-1879-102REPAIR SECTION 1(3-1/2" DOUBLE)4-3/4" CHAIN REPAIR LINKS *79-101REPAIR SECTION 1(4-3/4" DOUBLE)5-1/2" CHAIN REPAIR LINKS *79-093REPAIR SECTION 1(4" DOUBLE)*79-095REPAIR SECTION 1(5" DOUBLE)*79-096REPAIR SECTION 1(5-1/2" DOUBLE)* NOT ILLUSTRATEDHYDRAULICSTRENCHER FIGURE 4TRENCHERITEM PART NO.DESCRIPTIONQTY ITEMPART NO.DESCRIPTIONQTYHYDRAULICSFIGURE 44-123-070CYLINDER, HYD. 2 X 8121-13055X SEAL KIT14-264-852TOP PIN14-302-CP0512COTTER PIN, 5/32 X 1-1/244-425-2103-6-6 FITTING-90 DEG.24-520-017HOSE-1/4 X 7024-625-0103-4-6 FITTING-STR 24-723-004MALE QUICK COUPLER 24-864-853BOTTOM PIN 14-964-846SPACER, DEPTH GAUGE 14-1064-839.7DEPTH GAUGE W/A 14-1102-CP0410COTTER PIN, 1/8 X 1-1/414-1256-073GAUGE, DEPTH14-1362-822.7FRAME, BOOM PIVOT W/A 14-1464-835.7SAFETY TUBE W/A 100-224LABEL3(DANGER FOR TRENCHER)4-1599-K56BOLT-FLANGE 1/2-13X1-1/244-1664141-13NUT WLF 1/2-1344-1729-010S/B GREASE FITTING 1GEAR BOXTRENCHER FIGURE 5TRENCHERITEM PART NO.DESCRIPTIONQTYITEMPART NO.DESCRIPTIONQTYGEAR BOXFIGURE 55-187-CM000182 HOUSING 15-287-CM450064 COLLAR 15-387-CM150144 BEARING CUP 25-487-CM150136 BEARING CONE 25-587-CM370023 SHIM (.010) VARIES 5-687-CM370015 SHIM (.005) VARIES 5-787-CM620062 RETAINING RING 15-887-CM410233 LOCKWASHER 15-987-CM410255 LOCKNUT 15-1087-CM600031 KEY 15-1187-CM050237 HUB 15-1287-CM450585 COLLAR 15-1387-CM620088 RETAINING RING 15-1487-CM200287 SHAFT 15-1587-CM300251 SEAL 15-1687-CM150151 BEARING CONE 15-1787-CM150011 BEARING CUP 15-1887-CM410163 SEMS CAP SCREW 165-1987-CM390021 GASKET (.015)15-2087-CM390039 GASKET (.005)15-2187-CM390195 GASKET (.003)15-2287-CM101030 GEAR 15-2387-CM055327 THRU CAP 15-2487-CM452326 COLLAR 15-2587-CM600171 KEY 15-2687-CM222810 THRU SHAFT 15-2787-CM301473 SEAL 15-2887-CM150557 BEARING CONE 15-2987-CM150540 BEARING CUP 15-3087-CM101048 PINION 15-3187-CM410027 PIPE PLUG (SOLID)25-3229-079PIPE NIPPLE, 1/2 X 1.1/215-3324-033PIPE CAP, 1/2"1CRUMBERTRENCHER FIGURE 619TRENCHERITEM PART NO.DESCRIPTION QTY ITEM PART NO.DESCRIPTION QTYCRUMBER FIGURE 66-164-858.7PLATE-CRUMBER SIDE 26-264229-05LOCKNUT, 1/2-13 NYLON 66-390-0826BOLT,1/2-13 X 3-1/446-462-825.7LINK-TOP WLDMT 16-562-826.7LINK-BOTTOM WLDMT 16-664123-72BLT-HEX 1/2-13X2-1/226-762-824.7WLDMT-CRUMBER 1(USED WITH STANDARD DIGGING CHAIN)62-861.7WLDMT-CRUMBER 1(USED WITH 3-1/2" CHAIN)Equipment from Jacobsen, a Textron company,is built to exacting standards ensured byISO 9001 and ISO 14001 registration at all ourmanufacturing locations.A worldwide dealer network and factory-trainedtechnicians backed by Textron Parts Xpressprovide reliable, high-quality product support.BOB-CAT BROUWER BUNTON CUSHMAN RYAN STEINER。
BTA330B-800CT3Q Hi-Com TriacRev.01 - 16 October 2019Product data sheet1. General descriptionPlanar passivated high commutation three quadrant triac in a TO263 (D2PAK) surface mountableplastic package intended for use in circuits where high static and dynamic dV/dt and high dI T/dt canoccur. This triac will commutate the full RMS current at the maximum rated junction temperature(T j(max) = 150 °C) without the aid of a snubber. It is used in applications where high junction operatingrequired.iscapabilitytemperature2. Features and benefits• 3Q technology for improved noise immunity• High commutation capability with maximum false trigger immunity• High junction operating temperature capability (T j(max) = 150 °C)• High voltage capability• High current capability• Less sensitive gate for highest noise immunity• Triggering in three quadrants only• Very high immunity to false turn-on by dV/dt and fast transients• Surface mountable plastic package• Package is RoHS compliant3. Applications• Heating controls• High power motor control• High power switching• Applications subject to high temperature (T j(max) = 150 °C)4. Quick reference data5. Pinning information6. Ordering information7. Marking8. Limiting values Table 5. Limiting values9. Thermal characteristics10. Characteristics11. Package outline12. Legal informationData sheet status[1lease consult the most recently issued document before initiating or completing a design.[2]The term 'short data sheet' is explained in section "Definitions".[3]The product status of device(s) described in this document may havechanged since this document was published and may differ in case ofmultiple devices. The latest product status information is available onthe Internet at URL .DefinitionsDraft — The document is a draft version only. The content is still under internal review and subject to formal approval, which may result in modifications or additions. WeEn Semiconductors does not give any representations or warranties as to the accuracy or completeness of information included herein and shall have no liability for the consequences of use of such information.Short data sheet — A short data sheet is an extract from a full data sheet with the same product type number(s) and title. A short data sheet is intended for quick reference only and should not be relied upon to contain detailed and full information. For detailed and full information see the relevant full data sheet, which is available on request via the local WeEn Semiconductors sales office. In case of any inconsistency or conflict with the short data sheet, the full data sheet shall prevail.Product specification — The information and data provided in a Product data sheet shall define the specification of the product as agreed between WeEn Semiconductors and its customer, unless WeEn Semiconductors and customer have explicitly agreed otherwise in writing. In no event however, shall an agreement be valid in which the WeEn Semiconductors productis deemed to offer functions and qualities beyond those described in the Product data sheet.DisclaimersLimited warranty and liability — Information in this document is believedto be accurate and reliable. However, WeEn Semiconductors does notgive any representations or warranties, expressed or implied, as to the accuracy or completeness of such information and shall have no liability for the consequences of use of such information. WeEn Semiconductors takes no responsibility for the content in this document if provided by an information source outside of WeEn Semiconductors.In no event shall WeEn Semiconductors be liable for any indirect, incidental, punitive, special or consequential damages (including - without limitation -lost profits, lost savings, business interruption, costs related to the removal or replacement of any products or rework charges) whether or not such damages are based on tort (including negligence), warranty, breach of contract or any other legal theory.Notwithstanding any damages that customer might incur for any reason whatsoever, WeEn Semiconductors’ aggregate and cumulative liability towards customer for the products described herein shall be limited in accordance with the Terms and conditions of commercial sale of WeEn Semiconductors.Right to make changes — WeEn Semiconductors reserves the right to make changes to information published in this document, including without limitation specifications and product descriptions, at any time and without notice. This document supersedes and replaces all information supplied prior to the publication hereof.Suitability for use — WeEn Semiconductors products are not designed, authorized or warranted to be suitable for use in life support, life-criticalor safety-critical systems or equipment, nor in applications where failureor malfunction of an WeEn Semiconductors product can reasonablybe expected to result in personal injury, death or severe property or environmental damage. WeEn Semiconductors and its suppliers accept no liability for inclusion and/or use of WeEn Semiconductors products in such equipment or applications and therefore such inclusion and/or use is at the customer’s own risk.Quick reference data — The Quick reference data is an extract of the product data given in the Limiting values and Characteristics sections of this document, and as such is not complete, exhaustive or legally binding. Applications — Applications that are described herein for any of these products are for illustrative purposes only. WeEn Semiconductors makesno representation or warranty that such applications will be suitable for the specified use without further testing or modification.Customers are responsible for the design and operation of their applications and products using WeEn Semiconductors products, and WeEn Semiconductors accepts no liability for any assistance with applications or customer product design. It is customer’s sole responsibility to determine whether the WeEn Semiconductors product is suitable and fit for the customer’s applications and products planned, as well as for the planned application and use of customer’s third party customer(s). Customers should provide appropriate design and operating safeguards to minimize the risks associated with their applications and products.WeEn Semiconductors does not accept any liability related to any default, damage, costs or problem which is based on any weakness or defaultin the customer’s applications or products, or the application or use by customer’s third party customer(s). Customer is responsible for doing all necessary testing for the customer’s applications and products using WeEn Semiconductors products in order to avoid a default of the applicationsand the products or of the application or use by customer’s third party customer(s). WeEn does not accept any liability in this respect.Limiting values — Stress above one or more limiting values (as defined in the Absolute Maximum Ratings System of IEC 60134) will cause permanent damage to the device. Limiting values are stress ratings only and (proper) operation of the device at these or any other conditions above thosegiven in the Recommended operating conditions section (if present) or the Characteristics sections of this document is not warranted. Constant or repeated exposure to limiting values will permanently and irreversibly affect the quality and reliability of the device.No offer to sell or license — Nothing in this document may be interpreted or construed as an offer to sell products that is open for acceptance or the grant, conveyance or implication of any license under any copyrights, patents or other industrial or intellectual property rights.Export control — This document as well as the item(s) described herein may be subject to export control regulations. Export might require a prior authorization from competent authorities.Non-automotive qualified products — Unless this data sheet expressly states that this specific WeEn Semiconductors product is automotive qualified, the product is not suitable for automotive use. It is neither qualified nor tested in accordance with automotive testing or application requirements. WeEn Semiconductors accepts no liability for inclusion and/or use of non-automotive qualified products in automotive equipment or applications.In the event that customer uses the product for design-in and use in automotive applications to automotive specifications and standards, customer (a) shall use the product without WeEn Semiconductors’ warranty of the product for such automotive applications, use and specifications, and (b) whenever customer uses the product for automotive applications beyond WeEn Semiconductors’ specifications such use shall be solely at customer’s own risk, and (c) customer fully indemnifies WeEn Semiconductors forany liability, damages or failed product claims resulting from customer design and use of the product for automotive applications beyond WeEn Semiconductors’ standard warranty and WeEn Semiconductors’ product specifications.]PTranslations — A non-English (translated) version of a document is for reference only. The English version shall prevail in case of any discrepancy between the translated and English versions.TrademarksNotice: All referenced brands, product names, service names and trademarks are the property of their respective owners.13. Contents1. General description (1)2. Features and benefits (1)3. Applications (1)4. Quick reference data (1)5. Pinning information (2)6. Ordering information (2)7. Marking (2)8. Limiting values (3)9. Thermal characteristics (5)10. Characteristics (6)11. Package outline (9)12. Legal information (10)13. Contents (12)© WeEn Semiconductors Co., Ltd. 2019. All rights reservedFor more information, please visit: Forsalesofficeaddresses,pleasesendanemailto:**************************** Date of release: 16 October 2019。