真空泵说明书-内含泵剖面图
- 格式:pdf
- 大小:3.05 MB
- 文档页数:33
Types P 4 Z, P 12 ZP 6 Z, P 17 ZP 8 Z, P 23 Z3023162008-02-25We are constantly working on the further development of all our product types.Reprinting or reproduction of this manual, including extracts, is not allowed without the prior written permission of ILMVAC GmbH.All rights under the copyright laws are expressly reserved by ILMVAC GmbH.We reserve the right to make changes and amendments.ILMVAC GmbHAm Vogelherd 2098693 Ilmenau, GermanyTelephone: +49 36 77 60 40Fax: +49 36 77 60 41 10E-mail: info@ilmvac.deInternet: http://www.ilmvac.deContentsContents1Important Information (5)1.1General Information (5)1.2Target Groups (5)1.3Intended Use (5)1.4Use for an Unauthorized Purpose (5)1.5Safety Devices (6)1.6Meaning of the Warning notes (6)1.7Product Standards, Safety Regulations (6)2Basic Safety Instructions (7)2.1General Information (7)2.2Electricity (7)2.3Mechanical Systems (7)2.4Hazardous Substances (8)2.5High Temperatures (8)3Description (9)3.1Design (9)3.1.1Advantages (9)3.2Area of Application (10)3.3Function (10)3.3.1Working Principle (10)3.3.2Vacuum-tightness when switching off the suction port valve (11)3.3.3Gas ballast (12)3.4Scope of Delivery (12)3.5Accessories optional (13)3.5.1Overview and order numbers (13)3.5.2Condenser AKS 16 and AKS 25 (13)3.5.3Condenser AKD 16 and AKD 25 (14)3.5.4Main stream oil filter (14)3.5.5ILMVAC – Types of oil (15)3.5.5.1Features and applications (15)3.5.5.2Technical data (15)4Technical Data (16)4.1Dimensions (16)4.2Intake Pressure / Pumping Speed – Diagrams (17)4.3Device data (18)5Installation and Operation (20)5.1Unpacking (20)5.2General references (20)5.3Installation and Connection (20)5.4Connecting to the electricity supply (21)5.4.1Type of motor protection (21)5.5Selecting the operating oil (21)5.5.1Importance for the choice of the right oil (21)5.5.2Oil for drawing off oxygen (22)5.6Operation (23)5.6.1Starting-up (23)5.6.1.1Oil level (23)5.6.1.2Operating temperature (23)302316 3Contents5.7Use of the gas ballast when switching on (24)5.7.1Operation with gas ballast when drawing off condensable vapours (24)5.7.2Closing down (26)5.8Storage (26)5.9Scrap Disposal (26)6Maintenance and Servicing (27)6.1Maintenance Performed by the User (27)6.1.1Oil level control (27)6.1.2Topping-up the oil (27)6.1.3Oil check (28)6.1.4Oil change (28)6.1.4.1Draining the oil (28)6.1.4.2Filling up with oil (29)6.1.4.3Flushing (29)6.1.5Changing the oil type (29)6.2Maintenance by the Manufacturer (30)6.2.1Servicing (30)6.3Damage Report (30)7Troubleshooting (31)8Overview of spare parts (33)8.1Gasket set (33)8.2Maintenance kit (34)8.3View of spare part P 4 Z, P 6 Z, P 8 Z (35)8.3.1List of spare parts P 4 Z, P 6 Z, P 8 Z (36)8.4View of spare part P 12 Z, P 17 Z, P 23 Z (37)8.4.1List of spare parts P 12 Z, P 17 Z, P 23 Z (38)4 302316Important InformationInformation1 ImportantInformation1.1 GeneralThe ILMVAC Rotary Vane Pumps conform to the following directives:• 2006/95/EC Low Voltage DirectiveDirective• 2006/42/EC MachineryCompatibility Directive• 2004/108/EC ElectromagneticThe CE sign is located on the rating plate. Observe the binding national and local regulationswhen fitting the pump into installations.Our products are sold worldwide and can therefore be equipped with the typical nationalplugs and for the various voltages. You will find more information about the available pumpdesigns under http://www.ilmvac.de.Groups1.2 TargetThis Operating Manual is intended for the personnel planning, operating and maintainingILMVAC Rotary Vane Pumps.This group of people includes:• Designers and fitters of vacuum apparatus,• Employees working on commercial laboratory and industrial vacuum technology applica-tions and• Service personnel for rotary vane pumps.The personnel operating and maintaining the rotary vane pumps must have the technicalcompetence required to perform the work that has to be done.The user must authorize the operating personnel to do the work that has to be done.The personnel must have read and understood the complete Operating Manual before usingthe rotary vane pumps.The Operating Manual must be kept at the place of use and be available to the personnelwhen required.Use1.3 Intended• The layout of the rotary vane pump must be appropriate for the conditions of use. Theuser bears the sole responsibility for this.• The rotary vane pump may only be operated under the conditions stated– in the "Technical Data" section,– on the type plate, and– in the technical specification for the order concerned.1.4 Use for an Unauthorized PurposeIt is forbidden to use the pump for applications deviating from the technical data stated onthe type plate or the conditions stated in the supply contract, or to operate it with missing ordefective protective devices.302316 5Important InformationDevices1.5 SafetyMeasures such as the following are for the safety of the operating personnel:• electrical connection with a protective conductor (operating mode S1) and an earthing plug• Motor protection device (thermal) and• “Hot Surface" label on the pump body (warning notice).The rotary vane pump must not be operated without these elements.1.6 Meaning of the Warning notesTake note of the warning notes. They are in the following box:CAUTION ! / WARNING !Hazard which may lead to serious injuries or material damage.1.7 Product Standards, Safety RegulationsILMVAC Rotary Vane Pumps meet the following product standards:DIN EN 292-1, DIN EN 292-2 Safety of machines, basic terminologyDIN EN 1012-2 Compressors and vacuum pumpsDIN EN 60204-1 Electrical equipment of machinesEN 50110-1 (DIN VDE 0105-100) Operation of electrical installationsEN 61010-1 Safety for laboratory devicesEN 50081-1-2 Electromagnetic compatibility (EMC)Generic specification - Interference resistancefor residential, business and industrial areas, and small businesses EN 50082-1-2 Electromagnetic compatibility (EMC)Generic specification - Interference emissionfor residential, business and industrial areas, and small businesses EN 55014 Radio disturbance characteristics of electrical equipment andsystemsEN 61000-3-2/3 Electromagnetic compatibility (EMC)Directive 2006/42/EC Law and Administration Regulations relating to MachineryDirective 2002/95/EC RoHS Restriction of use of certain hazardous substancesThe following additional safety regulations apply in the FR Germany:BGV A2 Electrical equipment and operating materialsVBG 5 Power-driven machinesBGR 120 Guidelines for laboratoriesBGI 798 BG hazard assessment in the laboratoryBGG 919 Accident prevention regulations for "compressors"BGR 189 (BGR 195; 192; 197) Use of protective working clothesObserve the standards and regulations applying in your country when you use the rotaryvane pumps.6 302316Basic Safety Instructions2 Basic Safety InstructionsInformation2.1 GeneralWarning notices must be observed. Disregarding them may lead to damage to health andproperty.The rotary vane pumps must be operated by personnel who can detect impending dangersand take action to prevent them from materialising.The manufacturer or authorized authorised workshops will only service or maintain the rotaryvane pump if it is accompanied by a fully completed damage report. Precise information a-bout the contamination (also negative information if necessary) and thorough cleaning of therotary vane pump are legally binding parts of the contract.Contaminated rotary vane pumps and their individual parts must be disposed of in accor-dance with the legal regulations.The local regulations apply in foreign countries.2.2 ElectricityRotary vane pumps of operation mode S1 are supplied. Please note that the testing must berepeated in accordance with DIN EN 0105, DIN EN 0702 and BGV A 2 in case of portabledevices of operation mode S1. The local regulations apply in foreign countries.Please note the following when connecting to the electrical power supply system:• The electrical power supply system must have a protective connector according to DINVDE 0100-410 (IEC 60364-4-41).• The protective connector must not have any breaks.• The connecting cable must not be damaged.Systems2.3 MechanicalImproper use can lead to injuries or material damage. Observe the following instructions:• Only operate the rotary vane pumps with the specified flange-mounting components.• Hazardous substances must be separated out as far as this is technically possible beforethey reach the pump.• External mechanical stresses and vibrations must not be transmitted to the pump. Onlyuse flexible vacuum hoses for connecting Rotary Vane Pumps.• The pump must not be used to suck up fluids. Lay the exhaust pipe so that it slopesdownwards, so allowing condensate to flow out of the pump. Collect the condensate anddispose of it in an environmentally compatible manner.• Maintain a space of least 20 cm between the pump and adjacent parts in order to enablethe pump to cool.CAUTION !Solid particles in the pumping medium impair the pumping action and can lead todamage. Prevent solid particles penetrating into the pump!302316 7Basic Safety InstructionsSubstances2.4 HazardousCAUTION !The operating company bears the responsibility for the use of the rotary vane pump.Hazardous substances in the gases to be pumped can cause personal injuries and property damage. Pay attention to the warning notices for handling hazardous substances.The local regulations apply in foreign countries.Combustible GasesExamine before switching on whether that can form gas combustible gas/air mixtures which can be promoted! Consider the regulations of the guideline 1999/92/EC.It is not permitted to pump gases that are combustible or prone to explosion.Aggressive gasesThe rotary vane pumps is not certified according to ATEX guidelines 94/9/EC.Poisonous gasesUse a separator when pumping poisonous or harmful gases. Prevent such substances from leaking out of the appliance or pump. Treat these substances according to the applicableenvironmental protection regulations.Test the strength and leak-tightness of the connecting lines and the connected apparatus.Prevent environmental poisons, e.g. mercury, getting into the rotary vane pumps.Fulfil the requirements, for example:• German Hazardous Substances Regulation (GefStoffV) of 23. December 2004• Regulations 2006/121/EC (classification, packaging and identification of hazardous sub-stances),• Manufacturer's safety data sheets on hazardous substances.Temperatures2.5 HighThe rotary vane pump may heat up as a result of the temperature of the gas being pumpedand through intrinsic heating. The temperature of the rotary vane pump heads can reach80 °C during operation.Prevent the following maximum permissible temperatures from being exceeded.• + 40 °C for the environment, and• + 20 °C for the gas to be pumped.The motor is protected against overload by a suitable protective device.8 302316Description3 Description3.1 DesignThe ILMVAC P - Z series vacuum pumps are oil-sealed, two-stage rotary vane vacuumpumps.The drive motor is directly flange-mounted onto the motor cover of the pump holder.The pump shaft and the motor shaft are connected to each other by an elastic coupling.The bearings of the interior pump body are force-fed lubricated sliding bearings.1 Rotary knob for setting the gas ballast valve(direction of rotation: to the left = open, to the right = closed)2 Screw-plug for oil filling3 Type plate4 Oil inspection glass5 Oil drain screw-plug6 On / Off switch7 Drive motor8 Suction port9 Exhaust portFig. 1 Rotary Vane Pump P 23 Z3.1.1 Advantages• extremely compact construction and consequently small dimensions and low weight• vacuum pump is sealed after switching• quite running with low intake pressures• a gas ballast valve enables condensing vapours to be pumped out, it achieves a high tolerance ofwater vapour pressure• Suction and exhaust ports are designed with small flanges according to pneurop standard• The oil level can be checked on the oil level gauge• Important parts are easy to service and replace• The powerful oil circuit strengthens the purging and cleans the pump of particles of dirt and con-densates.• The rotary vanes are made of a special plastic. They are not affected by corrosion and not dam-aged by dirt particles and have very good sliding properties.• All elastomer seals are made of Viton.302316 9Description3.2 Area of ApplicationThe range of application of our oil-sealed rotary vane pumps encompasses the entire field of vacuum technology, both for use in the laboratory and in industry.The task is to create end pressures (partial) down to around 10 -4 mbar• as a single pump• as a fore-pump for oil diffusion pumps or as turbo-molecular pumps.The rotary vane pump can pump out biological, toxic and radioactive gases and vapours,and evacuate containers or vacuum installations up into the high vacuum range.Description The pump body is subdivided into several chambers by the eccentrically arranged rotorwhich has two radically sliding vanes. The volume of each chamber changes cyclically as the rotor turns. This sucks the gas into the intake opening. The gas flows through the dirt filter,which is connected to the centring ring, into the pump body. After the intake opening is clo-sed by the vane, the gas is transported onwards and compressed.A dosed quantity of air (gas ballast) can be let into the pump body during the compression byopening the gas ballast valve. This prevents vapours condensing in the vacuum pump.The maximum tolerance of water vapour pressure is 40 mbar.Oil is injected into the pump body for sealing and lubrication. An oil pump pumps oil out ofthe oil reservoir into a pressure oil lubrication system that feeds all the bearings. The low-mounted oil suction pipe achieves a large usable oil reserve.At the outlet valve, the compressed gas is pumped out of the pump body through the ex-haust port. The oil carried along with the gas is separated out by a filter (accessory).3.3.2 Vacuum-tightness when switching off the suction port valveVacuum-tightness when the pump is switched off is achieved by means of the hydraulicallyactuated suction port valve (HV-valve).The hydraulically actuated suction port valve closes the suction port vacuum-tight when theunit is shut down. This prevents venting and oil flowing back into a connected receptacle.1 Hydraulic piston2 Valve disk3 Pull-back spring4 Suction opening5 Venting holeFig. 3 Suction port valve (HV-valve)Descriptionballast3.3.3 GasCAUTION !Condensable vapours may only be extracted when the gas ballast valve is open,when the vacuum pump is at operating temperature and within the limits of the ma-ximum tolerance of water vapour pressure!Condensation occurs if the maximum water vapour pressure tolerance of 60 mbar isexceeded.When pumping condensable vapours, they may be compressed during the compressionphase above the saturated vapour pressure and condense.This causes considerable deterioration in the vacuum pump’s performance:• ultimate pressure is not achieved• corrosion occurs• heavy oil contamination and formation of emulsions.When the gas ballast valve opens (to the left), air flows into the compression space. The airflowing in keeps the partial pressure of the condensable medium so low that the pressureneeded to open the outlet valve is reached before the medium condenses.CAUTION !Operating with gas ballast increases the operating temperature of the vacuum pumpby 5 – 10 K.Should condensate form despite actuation of the gas ballast device, the suction port must be closed and the pump operated with gas ballast for a lengthy period (about 2 hours).3.4 Scope of DeliveryThe scope of delivery is specified in the supply contract.Description 3.5 Accessoriesoptional3.5.1 Overview and order numbersDescription Order no.Condenser AKS 16 (suction side) Condenser AKD 16 (pressure side) Condenser AKS 25 (suction side) Condenser AKD 25 (pressure side)300883 300884 300885 300886Replacement cartridge for AKD 16 and AKD 25 800160 Main stream oil filterOPF 40 M (for filtering solid particles)OPF 40 C (for neutralizing acidic ingredients in the oil)700153-02 700153-01Replacement cartridge for OPF 40 M Replacement cartridge for OPF 40 C 800170 828599Oil “LABOVAC 10” 1 litre 8001225 litres 80012010 litres 80012320 litres 800124200 litres 8001193.5.2 Condenser AKS 16 and AKS 25The suction-side condensate separator prevents condensates from the vacuum systems pe-netrating into the pump.It is directly flange-mounted onto the suction port of the pump by means of a DN 16 KFand/or DN 25 KF connector set. The horizontal arrangement of the separator alongside thepump prevents fluids running back from the collector or condensate vessel into the pump.Maintenance of the condenser is limited to simply emptying the collecting vessel.Technical data for P 4 - 6 Z for P 8 - 23 ZConnecting flange, suction and pressure-side DN 16 KF DN 25 KFSeparator - basic body Aluminium, chem. nickel-platedCollector or condensate vessel BorosilicateglassSeals Viton(FPM) Max. filling volume 380 mlDescription3.5.3 Condenser AKD 16 and AKD 25The pressure-side separator effectively reduces the oil mist emission from the pump's pres-sure port at high intake pressures.Technical data for P 4 - 6 Z for P 8 - 23 ZConnecting flange, suction and pressure-side DN 16 KF DN 25 KFSeparator - basic body Aluminium, chem. nickel-platedglassCollector or condensate vessel Borosilicate(FPM) Seals VitonFilter cartridge Optical fiberMax. filling volume 270 ml3.5.4 Main stream oil filterWe recommend using the mechanical main flow oil filter type OPF 40 M to filter mechanicalcontaminants out of the pump oil.To assemble: remove the sealing cover from the pump holder and screw on the filter. If theoil level is low, top the oil up to the mark during the test run.CAUTION !The main stream oil filter may only be installed when the pump is switched off.Description3.5.5ILMVAC – Types of oil3.5.5.1 Features and applicationsUse for Ilmvac pump types ILMVAC Oils Features single stage two stage ApplicationsLABOVAC 10Mineral oil based vacuum oil PS -Pumps P-Pumps(PK-Pumps)For all standard applications, that is for pump-ing out air, inert gases and water vapour, and also slightly acidic or basic vapours.LABOVAC 11Synthetic oilPS -Pumps Not usable ! for high operating temperatures of pumps usedfor low vacuums , that is intake pressures of <50 mbar in continuous operation, and in case of short-time pressure load changes,LABOVAC 11 is therefore specifically intended for PS pumps.LABOVAC 12S Mineral oil basedvacuum oil (paraffin oil)- P-Pumps (PK-Pumps) Special oil specially for use in two-stagepumps for plasma etching processes , a low-cost alternative to LABOVAC 13LABOVAC 13 Synthetic oil (Fomblin, PFPE oil)PS -Pumps P-Pumps(PK-Pumps) inert special oil for pumping oxygen and for plasma etching processesLABOVAC 14 Synthetic oil - P-Pumps(PK-Pumps)chemvac-Pump SystemsSpecial low viscosity oil, chemically stable and with a good demulsifying power. Advantage of low viscosity:The pump can be started at an oil temperature of 10°C, therefore particularly suitable for pumping in plant construction, in mobile leak finders, laser cutting and welding devices, vacuum load devices, and many others.Advantage of chemical stability and good demulsifying power:especially suitable for drying, freeze-drying and distillation processes, LABOVAC 14 is there-fore the standard oil for the chemvac pump systems3.5.5.2 Technical dataLABOVAC OilParameter Unit 10 11 12 S13 14 Ultimate pressure,total *)mbar3 – 5 x 10–31 x 10-23 x 10-35 x 10-33 x 10-3Vapour pressure at 20 °C 40 °C 100 °Cmbar10 -5 10 -4 10 -3 10 -5 10 -4 10 -3 10 -8 10 -7 10 -4 10 -6 - 10 -3 < 10 -6- - Viscosity at 20 °C 40 °C 100 °CcST- 118 12.5 - 110 - - 94 - 120 - - 103 47,9 7.4 max. permissible oil temperature in the vacuum pump ° C100> 150100> 150125 Flash point ° C 270 260 260notflammable257 Density at 15 °Cg / ml 0.888 0.96 0.886 1.890.918*) measured with two-stage rotary vane pump and Pirani vacuum gaugeThe technical data and operating characteristics of ILMVAC Rotary vane pumps are only guaranteed if original LABOVAC Oils are used!Technical Data4 Technical Data4.1 DimensionsABCDEFGPumptypeOrder no.DN - KF(mm)P 4 Z 302102 DN 16 KF 405 213 50 130 39 0 150 P 6 Z 302103 DN 16 KF 415 213 50 140 39 0 150 P 8 Z 302104 DN 25 KF 430 213 50 155 39 0 150 P 12 Z 302314 DN 25 KF 522 256 54 210 61 4 166 P 17 Z 302315 DN 25 KF 522 256 54 210 61 4 171 P 23 Z302316DN 25 KF52225654210614171Fig. 4 DimensionsTechnical Data 4.2 Intake Pressure / Pumping Speed – DiagramsTechnical Data4.3 Device dataParameterUnitP 4 ZP 6 ZP 8 ZPumping speed 50/60 Hz to DIN 28426 part 1 (pneurop)m³ / h -1 4.6 / 5.55.8 /6.67.2 / 8.6Ultimate pressurewith rated speed 1500/min (50 Hz)to DIN 28426 (pneurop)- without gas ballast partial 2 x 10-4- without gas ballast total 2 x 10-3- with gas ballast total mbar 1 x 10-2Max. inlet pressure bar 1 Max. outlet pressurebar 1 Max. Leak rate of inlet valve mbar l/s 7 x 10-5Connection flanges - DN 16 KF DN 16 KF DN 25 KF Ambient temperature°C + 20 to + 40Max. operating gas temperature °C + 40 Noise levelDIN 45635 part 13dB (A) < 53Water vapour tolerancembar 60 Oil fillingml 1100 1000 1200Voltage / Frequency (Different data upon customer request)V, Hz 230 , 50/60(115, 50/60)(230/400, 50/60)Motor power ml 0.37Operating mode -S 1 Type of protectionDIN EN 60529- IP 54 Class of insulationDIN EN 600034-1- F (160°C)Dimensions (W/D/H)mm 405/150/215 415/150/215 430/150/215Weightkg17,5 19,5 21,5Order numbers for :- Mains connection cable CEE 825885 - Mains connection cable UK 825878 - Mains connection cable CH 825877 - Mains connection cable US -825903Order numbers for :- Rotary vane pump 230 Vwithout mains connection cable 302102 302103 302104- Rotary vane pump 115 Vwithout mains connection cable 302102-01 302103-01 302104-01 - Rotary vane pump 230/400 V with mains connection cable- 302102-02 302103-02 302104-02Technical DataParameterUnitP 12 ZP 17 ZP 23 ZPumping speed 50/60 Hz to DIN 28426 part 1 (pneurop)m³ / h -1 11 / 13.216 / 19.221 / 25.2Ultimate pressurewith rated speed 1500/min (50 Hz) to DIN 28426 (pneurop)- without gas ballast partial 1.5 x 10-4- without gas ballast total 2 x 10-3- with gas ballast total mbar 3 x 10-3Max. inlet pressure bar 1 Max. outlet pressurebar 1 Max. Leak rate of inlet valve mbar l/s 7 x 10-5Connection flanges - DN 25 KF Ambient temperature°C + 20 to + 40Max. operating gas temperature °C + 40 Noise levelDIN 45635 part 13dB (A) < 54Water vapour tolerancembar 35 Oil fillingml 1400 1200 1000Voltage / Frequency (Different data upon customer request)V, Hz 230 , 50/60(115, 50/60)(230/400, 50/60)Motor power ml 0.55 0.75 0.75Operating mode -S 1 Type of protectionDIN EN 60529- IP 54 Class of insulationDIN EN 600034-1- F (160°C)Dimensions (W/D/H)mm 522/166/256 522/171/256 522/171/256Weightkg30,0 33,0 33,5Order numbers for :- Mains connection cable CEE 825885 - Mains connection cable UK 825878 - Mains connection cable CH 825877 - Mains connection cable US -825903Order numbers for :- Rotary vane pump 230 Vwithout mains connection cable 302314 302315 302316- Rotary vane pump 115 Vwithout mains connection cable 302314-01 302315-01 302316-01 - Rotary vane pump 230/400 V with mains connection cable- 302314-02 302315-02 302316-02Installation and Operation5 Installation and Operation5.1 UnpackingCarefully unpack the rotary vane pump.Check the pump for:• Transport damage,• Conformity with the specifications of the supply contract (type, electrical supply data),• Completeness of the delivery.Please inform Ilmvac GmbH without delay if there are discrepancies between the deliveryand the contractually agreed scope of delivery, or if damage is detected.Please take note of the general terms of business of ILMVAC GmbH.In case of a claim under warranty, the device must be returned in packaging that issuitable for protecting it during transport.references5.2 GeneralAccording to its intended use the capacity of the vacuum pump depends on:• the kind of assembly• accessories• the oil used• additional connections• vacuum piping system.In addition, fail-safe operation is determined by the mode of maintenance.Elements such as valves, filters, condensers a.s.o. should be provided as early as in theconception.The materials of the vacuum piping should be selected in such a way that they will be resis-tant to the media to be delivered!5.3 Installation and Connection1. Set the rotary vane pump on a flat and horizontal surface.2. Remove the protective caps on the suction and pressure ports.3. Close the vacuum connection on the suction port and the exhaust pipe on the pressureport. The suction and pressure ports must not be connected the wrong way round by mis-take!4. Connect the rotary vane pump to the electrical supply.Regularly check and clean the air inlet of the motor ventilator.The structural elements used on the inlet and outlet sides must be resistant to the media tothe pumped. The pressure on the outlet side must not exceed 0.5 bar!A pressure that is slightly below the air pressure helps to avoid pollution of gases, and re-duces corrosion.Installation and Operation 5.4 Connecting to the electricity supplyThe standard pump is supplied with complete electrical wiring. It is connected via an appli-ance cable and a power supply plug.WARNING !Should the user change the electrical connection, for example for fitting into a sys-tem, then this may only be performed by a skilled worker under observance of theaccident prevention regulations.It is generally suggested to protect the motor by 120 per cent of is rated power in considera-tion of the starting and switch-on response.With pumps with three-phase motor, the direction of rotation of the motor must be checkedbefore starting the vacuum pump for the first time.The vacuum pump may be destroyed if the motor rotates in the wrong direction.Device connection cables and plugs must comply with the requirements of the line discon-nection devices (current, output).The customer/user shall install the main and emergency stop switches.5.4.1 Type of motor protectionAll A.C. motors are provided with a thermal overload protection ex works, protecting the mo-tor and vacuum pump from damage or destruction, respectively.All poles of three-phase motor must, as it were, be protected by cut-outs.5.5 Selecting the operating oil5.5.1 Importance for the choice of the right oilWARNING !We recommend the use of LABOVAC Oils. These special oils are not harmful tohealth when used properly!The oil fulfills the following functions in the vacuum pump:• Lubricating the sliding parts, such as rotor, vane, radial shaft seals• Sealing the moving parts against the stator wall to reduce leaks• Conducting the heat of compression to the metal walls (cooling).。
Sk-15真空泵须报经国务院批准;对到期的专项转移支付项目要及时清理,逐步整合现有专项转移支付项目,统筹安排转移支付资金;改进资金分配机制,对明显属于地方事权范围内的事项,具体项目的确定交由省级政府办理。
中央主管部门主要通过政策、规划和必要的监督检查,指导地方管好用好专项转移支付资金,促进经济和各项社会事业发展。
苏明:要严格按照国家政策意图和事权划分原则,清理和压缩现有的专项拨款项目,只有国家鼓励、并且属于国家和地方共同负担的事项,中央才设立专项转移支付,属于地方支出责任范围内的事务,中央不安排专项。
还应取消现有专项转移支付中名不符实和过时的项目,归并重复交叉的项目。
对已形成地方固定财力的纳入一般性转移支付,严格控制专项转移支付规模。
严格专项转移支付审批程序,规范专项转移支付分配办法。
另外,已有的中央财政专项转移支付过多地要求地方财政有相应的配套资金。
这直接导致未能拿出足够财力配套、但实际上【SK系列水环式真空泵】产品简介:SK系列水环式真空泵及压缩机是用来抽吸或压送气体和其它无腐蚀性、不溶于水、不含有固体颗粒的气体,以便在密闭容器中形成真空或压力,满足工艺流程要求。
吸入或压送的气体中允许混有少量的液体。
SK系列水环式真空泵及压缩机广泛应用于机械、石油、化工、制药、陶瓷、制糖、印染、冶金及电子等行业。
由于在工作过程中,该类泵对气体的压缩是在等温状态下进行的,因此在压送或抽吸易燃易爆气体时,不易发生危险,所以其应用更加广泛。
【SK系列水环式真空泵】型号意义:【SK系列水环式真空泵】结构图:【SK系列水环式真空泵】结构说明:SK系列水环式真空泵的结构如图2、图3、图4所示。
泵由泵体、两个端盖、叶轮、轴等部件组成。
进气和排气竹通过安装在端盖上的园盘上的吸气孔和样气孔与泵腔相连,轴偏心地安装在泵体中,叶轮用平键固定在轴上。
泵两端而的总间隙山泵体和园盘之间的垫来调整,叶轮与端盖上的园盘之间的间隙由轴套(SK-1.5/3/6)或背帽(SK-12/20/30)推动叶轮来调整,而(SK-42以上轴与叶轮为过盈配合,此间隙由前端定位时确定.SK-42-60-85-120无轴套,其余结构与SK-6/12/20/30相同。
JIANG YIN TIANTIAN V ACUUM EQUIPMENT.CO.,LTD.ZJ型 ZJP 型罗茨真空泵安装使用维护手册中华人民共和国江阴天田真空设备制造有限公司地址:中国江阴云亭工业区B区松文头路19号邮编:214422电话: 86-0510-*******销售直线:86-0510-*******传真: 86-0510-*******目录A.安全警告-------------------------------------------------------------------------3B.概述----------------------------------------------------------------------------4C.主要技术参数------------------------------------------------------------------ 6D.安装说明-------------------------------------------------------------------------7E.使用说明-------------------------------------------------------------------------8F.维护检查及产品维修--------------------------------------------------------- 9G.故障原因与消除方法----------------------------------------------------------17H.易损件表-------------------------------------------------------------------------15-------------------------------------------------------- 16A.安全警告1.本产品不能单独使用,必须在配备由本公司专业技术人员推荐的前级真空泵的前提下才可投入使用。
水环式真空泵全解析,有图、有动画1.水环式真空泵是带有多叶片的转子偏心装在泵壳内。
当它旋转时,把液体抛向泵壳并形成与泵壳同心的液环,液环同转子叶片形成了容积周期变化的旋转变容真空泵。
当工作液体为水时,称水环式真空泵。
水环真空泵就是这种靠偏置叶轮在泵腔内回转运动使工作室容积周期性变化以实现抽气的真空泵。
它的工作室由旋转液环和叶轮构成,其结构和工作原理与液环压缩机相似。
下面这个3D动画比较直观:水环真空泵工作原理水环泵工作轮2在泵体1中旋转时形成了水环3和工作室5,水环与工作轮构成了月牙形空间。
右边半个月牙形的容积由小变大,形成吸气室。
左边的半个月牙形的容积由大变小,构成了压缩过程(相当于排气室)。
被抽气体由进气管8和进气口4进入吸气室。
转子进一步转动,使气体受压缩,经过排气口6和排气管7排出。
排出的气体和水滴由排气管道7进入水箱10,此时气体由水中分离出来,气体经管管道9排到大气中,水由水箱进入泵中,或经过管道11排到排水设备中。
当工作液体为水时,称水环式真空泵,水环真空泵是一种粗真空泵,它所能获得的极限真空为2000~4000 Pa,串联大气喷射器可达270~670 Pa。
水环真空泵示意图:当叶轮按图中顺时针方向旋转时,水被叶轮抛向四周,由于离心力的作用,水形成了一个决定于泵腔形状的近似于等厚度的封闭圆环。
水环的下部分内表面恰好与叶轮轮毂相切,水环的上部内表面刚好与叶片顶端接触(实际上叶片在水环内有一定的插入深度)。
此时叶轮轮毂与水环之间形成一个月牙形空间,而这一空间又被叶轮分成和叶片数目相等的若干个小腔。
如果以叶轮的下部0°为起点,那么叶轮在旋转前180°时小腔的容积由小变大,且与端面上的吸气口相通,此时气体被吸入,当吸气终了时小腔则与吸气口隔绝;当叶轮继续旋转时,小腔由大变小,使气体被压缩;当小腔与排气口相通时,气体便被排出泵外。
水环真空泵(简称水环泵)是一种粗真空泵,它所能获得的极限真空为2000~4000Pa,串联大气喷射器可达270~670Pa。
RUVAC WA/WAU 251/501/1001/2001 罗茨真空泵安装使用说明书 300419381_011_C3产品号:112 54TE113 22/42TE117 20/30/40/50TE117 21/31/41/51TE117 21/31/41/51FP117 34TE118 31/41/51TE128 38TE155 011VTEIE3电机目录页码0重要安全信息50.1机械危害50.2电气危害60.3热危害70.4材料和物质引起的危害70.5引燃的危险80.6噪音危害80.7损坏泵的风险91概述 101.1设计与功能 101.1.1 工作原理 101.1.2 设计 121.1.3 压力平衡通道 131.1.4 润滑油 131.2标准规格 131.3技术参数 141.4订货信息 182运输与贮存 193安装 203.1安装 203.1.1 注油 213.2适合的应用 223.2.1 不适合的应用 223.3电气连接 233.4法兰连接 264运行 274.1启动 274.2运行 274.3停泵与贮存 284.4卧式转换立式 28 2 30041381_011_C3 - 03/2019 - © Leybold目录页码5维护 305.1安全信息 305.2换油 / 齿轮箱 315.3换油 / 轴封箱 325.4清洁风扇罩及散热筋 335.5清洁滤网 335.6清洁泵腔 335.7清洁压力平衡阀 345.8更换轴封 355.8.1 准备工作 355.8.2 RUVAC WA/WAU 251, 501 355.8.3 RUVAC WA/WAU 1001, 2001 365.9莱宝售后服务 385.10维护计划 396故障分析 407易损件和原装备件 428废物处理 42EC声明43本说明书为德文说明书GA03107_001_C1译本的衍生版本。
30041381_011_C3 - 03/2019 - © Leybold34 30041381_011_C3 - 03/2019 - © Leybold感谢阅读以下信息在安装和试运行泵前,为确保一开始就处于最佳条件且安全地工作,请认真阅读本说明书和下列信息。