蓄电池的检修
- 格式:ppt
- 大小:3.70 MB
- 文档页数:48
蓄电池检修流程1.检查蓄电池外观是否有明显损坏,如裂纹或变形。
Check if there are any obvious damages on the appearance of the battery, such as cracks or deformations.2.检查蓄电池连接线是否松动或腐蚀。
Check if the battery connection wires are loose or corroded.3.测量蓄电池的电压,确保处于正常范围内。
Measure the voltage of the battery to ensure it is within the normal range.4.检查蓄电池的端子是否被腐蚀,需要及时清洁。
Check if the battery terminals are corroded and clean them in a timely manner.5.检查蓄电池的液位,需要加注蒸馏水至适当液位。
Check the liquid level of the battery and add distilled water to the appropriate level.6.检查蓄电池的电解液浓度,必要时进行调整。
Check the concentration of the battery electrolyte and make adjustments if necessary.7.检查蓄电池的保护装置,确保工作正常。
Check the protective devices of the battery to ensure they are functioning properly.8.清洁蓄电池表面,去除污垢和尘埃。
Clean the surface of the battery to remove dirt and dust.9.进行蓄电池的放电测试,以确定其性能状态。
蓄电池使用、维护、检修规程QJ/1TD7.12-2002 1总则1.1 本章内容适用于变电所用蓄电池组的检修。
其它场所用的蓄电池亦可参照执行。
国外引进的设备,应按厂家规定执行,如无规定,亦可参照执行。
1.2 本章的技术标准是参照国家标准骰备安装工程施工及验收规范》,冶金工业部标准《冶金工业电气设备技术规程》而制定的。
在使用中如有未尽事宜,亦应按国家有关规范执行。
1.3蓄电池的检修均应按已批准的方案进行施工。
14凡使用的器材均应符合国家或部颁的现行标准,并有合格证件,设备应有铭牌。
1. 5所采用的器材或原材料具有下列情况之一者,应重做试验:1.5. 1超过规定的保管期;15.2因保管,运输不良等原因而有变质损坏的可能;1.5. 3对原试验结果有怀疑;1. 6后电池检修前应做好下列准备方可施工。
1.6. 1测量仪表及工具齐全;1.6.2必备材料和备品备件到齐;1.6.3充放电设备和通风,照明等装置可靠好用;16.4出厂说明书或修理有关资料,图纸备齐;1.6. 5防护用品完好,齐全(如:防护眼镜.防酸服.耐酸碱橡胶手套.靴子.围裙等);1.7. 6先配制好电解液备用;1.8. 蓄电池安装有关的建筑物的土建工程的检修应符合国家现行的建筑工程施工及验收规范中的有关规定。
1. 8施工中的安全技术措施应遵守现行的有关安全技术规程的规定。
1.9本章不包括蓄电池的台架.箱柜.母线和充电设备的检修。
但蓄电池在组装前要求:1.9.1 台架如用木制改做时,可用干燥.平直无大木节及无贯穿裂缝的多树脂木材(如红松)制成安装平直,表面应涂耐酸漆或焦油沥青;用其它绝缘材料制作,应符合耐酸.防腐的要求;1.9. 2箱柜本体各构件装配牢固,漆层完整,封闭良好等,详见本规程第三章的有关规定;1.9.3母线应排列整齐,平直,固定牢固,弯曲度一至,全长涂以耐酸相色漆(正极为储色,负极为兰色)外表再涂一层凡土林油,详见本规程第三章的有关规定。
蓄电池的结构认知与检修蓄电池是一种将化学能转化为电能的装置,广泛应用于各种电力系统和电子设备中。
了解蓄电池的结构和维护对于正确使用和保养蓄电池非常重要。
下面将对蓄电池的结构认知和检修进行详细阐述。
蓄电池的主要结构包括正极板、负极板、电解质、电解液、阀控推进器以及外壳等部分。
1.正极板和负极板:正极板和负极板是蓄电池内最重要的组件。
它们由钢网或铅合金制成,并覆盖有活性物质,如铅二氧化物(正极)和松香炭(负极)。
正极板和负极板的作用是增加蓄电池的表面积,从而提高电池的电荷和放电能力。
2.电解质和电解液:电解质是蓄电池中液体的一部分,它包括盐酸或硫酸等化学物质。
电解质的作用是稳定电极反应并维持电池内部的电解质平衡。
电解液是电解质的溶剂,通常为蒸馏水。
3.阀控推进器:阀控推进器是蓄电池内将电解液注入电池中的装置。
它能控制电池内的压力,使电解液保持在合适的水平,以防止电池过充或过放。
4.外壳:蓄电池通常有一个外壳来保护内部零件。
外壳通常由塑料或钢制成,以确保电池具有足够的强度和绝缘性能。
蓄电池的检修蓄电池的检修主要包括以下几个方面:1.清洁蓄电池外部:蓄电池的外部应保持清洁,以防止灰尘、污垢和湿气进入电池内部。
可以使用湿布轻轻擦拭电池壳体,但不要使用化学溶剂或清洁剂,以免损坏外壳。
2. 检查电解液水平:定期检查蓄电池的电解液水平,确保液面位于蓄电池内壁上缘以下0.5cm处。
如果液面过低,应小心地添加蒸馏水,但不要过量添加。
3.检查蓄电池连接器和绝缘:检查蓄电池连接器和绝缘件的松动或损坏情况。
如果发现松动或损坏,应进行修复或更换。
4.检查蓄电池内阻:使用蓄电池内阻检测仪检测蓄电池的内阻。
内阻过大可能表明蓄电池已损坏,需要更换。
5.充电和放电测试:定期进行蓄电池的充电和放电测试,以确保其正常工作。
充电测试可以检测蓄电池的充电效率,放电测试可以评估蓄电池的容量和性能。
总结蓄电池是一种重要的电力存储设备,正确了解其结构和维护对于保持蓄电池的性能和延长寿命至关重要。
步骤1,检测蓄电池的外部状态
检查电池的形状是否完好。
检查电池外壳是否凸出、夜间漏液、破损、电池端子腐蚀等。
如果有这种现象,说明电池已经没电了。
它需要被替换。
第二步:检查电池电压是否正常。
1.充电完成后(两小时后),检查每个单体电池的电压三次,每次间隔20分钟。
如果单个电池的电压超过15V或者单个电池的电压始终低于13V,说明这个电池有一定的疑点;
2.放电完成后,用万用表测量每个单体电池的电压三次,每次间隔10分钟。
如果单个电池的电压下降速度比其他电池快,并且低于10V,并且这个电池的放电时间最短,那么这个电池就是问题电池。
3.检查单体电池的静态电压(浮电)。
电压为零时,有两种可能:一种是电池完全断开,电路堵塞,电压为零;另一种是电池放置时间过长,电压低至1-2V,甚至为零。
第三步:检查蓄电池电解液是否“脱水”发黑。
电解液是否变质或“失水”。
电池充电3-6小时后,用手触摸每个电池外壳的侧面。
如果电池很热,说明电池已经没电了。
如果只是发烧,温度在40度左右,同时充电器在充电时一直亮红灯,说明电池严重“脱水”;此外,可以打开电池的盖子来检测“失水”状态。
电解液是否发黑可以直接判断电池极板的好坏。
打开电池上方的盖子,可以看到六个圆孔。
检查每个孔中电解液的颜色。
如果是黑色,说明电极板上的铅粉掉了,这个电池没电了。
蓄电池核对性充放电检修工艺一、蓄电池核对性充放电必应严格按周期进行。
变电所蓄电池核对性充放电每年进行一次。
进行蓄电池核对性充放电的过程必须做详细的记录,包括:蓄电池核对性充放电的时间、操作程序、测量记录、运行方式(均充、浮充)、容量计算、环境温度、测量人等。
二、蓄电池核对性充放电的一般程序(以100Ah,12V为例):1.对其中一组蓄电池核对性充放电时,另一组蓄电池必须保证充足电。
严禁对两组蓄电池同时进行放电。
2.先对蓄电池进行均充电。
进行均充电的目的是使蓄电池达到其额定容量。
对于自动均充的直流系统,将蓄电池转入自动均充运行,当蓄电池由自动均充运行转为浮充运行2小时后对蓄电池进行放电。
3.在对蓄电池进行核对性充放电前,要对蓄电池进行全面测量,并将测量数据写入相应的记录,同时记录当时的环境温度、运行方式(含充放电电压电流)、测量时间、测量人等。
4.以10小时放电率对蓄电池进行放电,单组标准容量为100Ah的蓄电池,以10A恒定电流进行放电。
(65Ah的以6.5A恒定电流放电)A、放电的过程中,要每隔1小时定期对蓄电池进行测量一次:当蓄电池放出额定容量的70%或者某一单瓶电压接近10.80V(1.80×6)时,要每隔10分钟对蓄电池进行测量一次;当蓄电池某一单瓶电压达到10.80V(1.80×6)时,应立即停止放电。
B、当蓄电池放出的容量较少而某一单瓶电压已经达到10.80V(1.80×6)时,要立即停止放电,并将蓄电池转为均衡充电方式运行,在该单瓶充满、电压达到稳定的正常单瓶电压后转入浮充2小时以上,重新进行放电,过程同A;经过一定的均衡充电,该单瓶电压仍然达不到稳定的正常单瓶电压,则要将该瓶退出运行并对其进行单独充电,直到该单瓶电压达到稳定的正常单瓶电压(如果仍然达不到稳定的正常单瓶电压,说明该电瓶不合格)后,将其连接到原来的电池组中,重新进行A的过程。
C.经过几次均衡充电,某一单瓶放出容量不足80%时电压达到10.80V 时,其他蓄电池电压较高且整组蓄电池放出未达到85%,该蓄电池容量明显小于其他蓄电池容量时,可将该蓄电池甩开继续放电,或更换该蓄电池重新充放电。
酸性含铅蓄电池检修流程英文回答:Acidic lead-acid battery maintenance process.Maintaining and repairing acidic lead-acid batteries is an important task to ensure their optimal performance and longevity. Here, I will outline the step-by-step processfor maintaining these batteries.Step 1: Safety precautions.Before starting any maintenance work, it is crucial to ensure personal safety. This involves wearing appropriate protective gear such as gloves, goggles, and a face mask. Additionally, make sure to work in a well-ventilated area to minimize exposure to harmful fumes.Step 2: Visual inspection.Begin by visually inspecting the battery for any signs of damage or leakage. Look for cracks, bulges, or corrosion on the battery casing. If any issues are detected, it is important to address them before proceeding with the maintenance process.Step 3: Cleaning the battery.Next, clean the battery terminals and connectors using a mixture of baking soda and water. This will help remove any corrosion or buildup that may hinder the battery's performance. Gently scrub the terminals and connectors with a wire brush or a battery terminal cleaner. Rinse with clean water and dry thoroughly.Step 4: Checking electrolyte levels.Check the electrolyte levels in each cell of the battery. Ensure that the plates are fully submerged in the electrolyte solution. If the levels are low, top up with distilled water. Avoid overfilling, as it can lead to electrolyte overflow during charging.Step 5: Charging the battery.Connect the battery to a suitable charger and follow the manufacturer's instructions for charging. It is important to use a charger specifically designed for lead-acid batteries to avoid overcharging or damaging the battery. Monitor the charging process and disconnect the charger once the battery is fully charged.Step 6: Testing the battery.After charging, it is essential to test the battery to assess its capacity and overall health. This can be done using a battery load tester or a multimeter. Check the voltage and ensure it falls within the recommended range. If the battery fails the test, it may need to be replaced.Step 7: Reinstalling and securing.Once the battery has been maintained and tested, reinstall it in the appropriate location. Ensure that it issecurely fastened to prevent any movement or vibrations during operation.中文回答:酸性含铅蓄电池检修流程。
酸性含铅蓄电池检修流程英文回答:Acidic lead-acid battery maintenance procedure.As a technician responsible for maintaining andrepairing lead-acid batteries, I follow a specificprocedure to ensure their longevity and optimal performance. Here is the step-by-step process I follow:1. Safety first: Before starting any maintenance work,I always wear appropriate personal protective equipment (PPE) such as safety goggles, gloves, and a lab coat. Thisis essential to protect myself from any potential hazards associated with battery acid.2. Visual inspection: I begin by visually inspectingthe battery for any signs of damage or leakage. I check for cracks in the battery casing, loose connections, or anyother visible abnormalities. If I notice any issues, Iaddress them before proceeding further.3. Battery cleaning: Next, I clean the battery terminals and connections using a mixture of baking soda and water. This helps remove any corrosion or buildup that may hinder the battery's performance. I gently scrub the terminals with a wire brush and rinse them thoroughly with clean water.4. Electrolyte level check: I carefully remove the battery caps and check the electrolyte levels in each cell. If the levels are low, I add distilled water to bring them up to the recommended level. It's important not to overfill the cells, as it can lead to electrolyte overflow during charging.5. Specific gravity measurement: Using a hydrometer, I measure the specific gravity of the electrolyte in each cell. This provides an indication of the battery's state of charge and overall health. If I notice significant variations in specific gravity between cells, it may indicate a problem with individual cells or the battery asa whole.6. Charging: If the battery requires charging, I connect it to an appropriate charger and monitor the charging process. I ensure that the charging voltage and current are within the manufacturer's recommended limits. Overcharging can lead to excessive gas formation and damage to the battery plates.7. Load testing: Once the battery is fully charged, I perform a load test to assess its capacity and ability to deliver power. I connect a load tester to the battery and apply a specific load for a specified period. If the battery fails to meet the required voltage and current levels, it may indicate a need for replacement.8. Reassembly and final inspection: After completingall the necessary maintenance tasks, I reassemble the battery, ensuring all connections are tight and secure. I conduct a final visual inspection to verify that everything is in order before returning the battery to service.中文回答:酸性含铅蓄电池检修流程。
电动车蓄电池的检修技能
一、外观检查
1. 检查蓄电池外观是否完好,有无破损、变形、腐蚀等现象。
2. 检查蓄电池安装是否牢固,确保没有松动或移位的情况。
二、电压检测
1. 使用电压表或万用表测量蓄电池的电压,检查电压是否在正常范围内。
2. 分别测量蓄电池的正负极电压,判断是否存在极性反接的情况。
三、电解液检查
1. 检查蓄电池的电解液液面高度,确保电解液没有过低或过高。
2. 检查电解液的颜色和纯净度,判断是否存在杂质或污染。
四、充电状态检测
1. 了解蓄电池的充电方式,如恒流充电、恒压充电等,检查充电状态是否正常。
2. 使用专业设备或仪器检测蓄电池的充电参数,如充电电流、充电时间等。
五、连接线路检查
1. 检查蓄电池与电源、控制器等之间的连接线路是否牢固,有无松动或腐蚀现象。
2. 检查线路的导电性能是否良好,有无短路、断路或接触不良的情况。